diff --git a/backend/epc_api/json_samples/RdSAP-Schema-17.1/corpus.jsonl b/backend/epc_api/json_samples/RdSAP-Schema-17.1/corpus.jsonl new file mode 100644 index 00000000..58d1f6a2 --- /dev/null +++ b/backend/epc_api/json_samples/RdSAP-Schema-17.1/corpus.jsonl @@ -0,0 +1,1000 @@ +{"uprn": 100090470222, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO4 3XN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 4, "created_at": "2017-07-21 18:42:18", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "25, Penrice Close", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-06-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.28, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.28, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 422, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 86, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 387, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2314, "space_heating_existing_dwelling": 6752}, "energy_consumption_current": 90, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 66, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "B", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 16, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100051223691, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BD4 8NA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BRADFORD", "built_form": 4, "created_at": "2017-07-28 15:54:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16513}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Sutton Crescent", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 630, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 439, "currency": "GBP"}, "hot_water_cost_current": {"value": 192, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 8, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 136, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3003, "impact_of_loft_insulation": -497, "space_heating_existing_dwelling": 8661}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 98, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10013059429, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 31% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SR7 7WW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SEAHAM", "built_form": 1, "created_at": "2017-09-28 18:17:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8703}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Craster Point", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 128, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.64, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 34.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 63.42, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 31, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 637, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 132, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 645, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2988, "space_heating_existing_dwelling": 10209}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 121, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100121011251, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SN14 0BG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHIPPENHAM", "built_form": 1, "created_at": "2017-06-28 14:52:11.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Orchard Crescent", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.32, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.245, "quantity": "metres"}, "total_floor_area": {"value": 38.08, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.04, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 611, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 532, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2219, "impact_of_loft_insulation": -71, "space_heating_existing_dwelling": 10581}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 108, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 50541, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS16 4BE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2017-07-31 14:54:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Marshfield Road", "assessment_type": "RdSAP", "completion_date": "2017-07-31", "inspection_date": "2017-07-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.471, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.415, "quantity": "square metres"}, "party_wall_length": {"value": 4.971, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.427, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.426, "quantity": "metres"}, "total_floor_area": {"value": 39.136, "quantity": "square metres"}, "party_wall_length": {"value": 5.024, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.604, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 441, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 404, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1997, "space_heating_existing_dwelling": 7164}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "9.0.0", "energy_consumption_potential": 81, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 2465148694, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To external air, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [1]}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LE2 9PQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 4, "created_at": "2017-07-31 16:18:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8361}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "262, Hillsborough Road", "address_line_2": "Glen Parva", "assessment_type": "RdSAP", "completion_date": "2017-07-31", "inspection_date": "2017-07-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 36.02, "quantity": "square metres"}, "party_wall_length": {"value": 11.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.37, "quantity": "square metres"}, "party_wall_length": {"value": 4.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.2, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 503, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 399, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2075, "space_heating_existing_dwelling": 6881}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 85, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050647260, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "S70 1QE", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BARNSLEY", "built_form": 4, "created_at": "2017-07-23 09:33:16.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "95, Park Grove", "assessment_type": "RdSAP", "completion_date": "2017-07-23", "inspection_date": "2017-07-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.25, "quantity": "square metres"}, "party_wall_length": {"value": 4.85, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 19.25, "quantity": "square metres"}, "party_wall_length": {"value": 4.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.67, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.43, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 26.67, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.43, "quantity": "square metres"}, "party_wall_length": {"value": 3.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 7.43, "quantity": "square metres"}, "party_wall_length": {"value": 3.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1208, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 572, "currency": "GBP"}, "hot_water_cost_current": {"value": 283, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 358, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 9, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 262, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3907, "impact_of_loft_insulation": -321, "impact_of_solid_wall_insulation": -5150, "space_heating_existing_dwelling": 15550}, "energy_consumption_current": 411, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 118, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200004719958, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG14 2AY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWBURY", "built_form": 4, "created_at": "2017-09-21 15:20:52.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15708}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "15 Bramlings House", "address_line_2": "Craven Dene", "address_line_3": "London Road", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 47.53, "quantity": "square metres"}, "party_wall_length": {"value": 13.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 147, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.8, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 147, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1661, "space_heating_existing_dwelling": 700}, "energy_consumption_current": 99, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.92, "energy_consumption_potential": 99, "environmental_impact_current": 88, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "B", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 17, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 45120486, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DH4 6LB", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-05-31 21:41:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "66, Durham Street", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-05-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.01, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 479, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 322, "currency": "GBP"}, "hot_water_cost_current": {"value": 368, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 200, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 290, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4785, "space_heating_existing_dwelling": 5259}, "energy_consumption_current": 513, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "1.0.x", "energy_consumption_potential": 82, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 91, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061848419, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RH10 4LY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CRAWLEY", "built_form": 2, "created_at": "2017-06-22 16:13:57", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15012}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Bothy", "address_line_2": "Turners Hill Road", "address_line_3": "Worth", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-21", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 234, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.5, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 50.9, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1647, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1101, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 348, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}], "co2_emissions_potential": 6.6, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 104, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3021, "impact_of_loft_insulation": -1790, "impact_of_cavity_insulation": -7564, "impact_of_solid_wall_insulation": -1950, "space_heating_existing_dwelling": 34216}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 115, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 30, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 33007500, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 91% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TW18 2SE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAINES-UPON-THAMES", "built_form": 1, "created_at": "2017-09-21 17:52:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17568}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "16, The Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 181, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 35.69, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "C"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.47, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 30.46, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "I"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 91, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1320, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 834, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 96, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2994, "impact_of_loft_insulation": -2036, "impact_of_solid_wall_insulation": -3547, "space_heating_existing_dwelling": 26515}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 114, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 33, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 30} +{"uprn": 45103453, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DH4 5LA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-06-01 03:16:35", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "57, Abbey Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.59, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 709, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 488, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}, {"sequence": 7, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 98}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2040, "space_heating_existing_dwelling": 8856}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 114, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031034048, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN10 6BG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUSHDEN", "built_form": 1, "created_at": "2017-05-31 11:16:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16375}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Larkhill", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-04-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 168, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 69.85, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 14.14, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "E"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.14, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1474, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 854, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 354, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 109, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 107, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2264, "impact_of_loft_insulation": -917, "impact_of_cavity_insulation": -6423, "space_heating_existing_dwelling": 25847}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 30, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 10009576991, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HR7 4SL", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BROMYARD", "built_form": 1, "created_at": "2017-06-22 12:47:30", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1778}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Little Hegdon", "address_line_2": "Pencombe", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 276, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 111.758, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 25, "wall_dry_lined": "Y", "wall_thickness": 500, "wall_construction": 2, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 111.758, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.69, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.131, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 2418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 17, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 185, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1406, "currency": "GBP"}, "hot_water_cost_current": {"value": 189, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 444, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 49}, {"sequence": 6, "typical_saving": {"value": 235, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 7, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 8, "typical_saving": {"value": 178, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 9, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}], "co2_emissions_potential": 8.5, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 114, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3546, "impact_of_loft_insulation": -2948, "impact_of_solid_wall_insulation": -1219, "space_heating_existing_dwelling": 44345}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100021269116, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HA3 5EE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 3, "created_at": "2017-04-21 20:19:23.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15977}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "207a, High Road", "assessment_type": "RdSAP", "completion_date": "2017-04-21", "inspection_date": "2017-04-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.51, "quantity": "metres"}}, "total_floor_area": 30, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 3, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.13, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 30.16, "quantity": "square metres"}, "party_wall_length": {"value": 8.02, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 16.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 475, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 383, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 63}], "co2_emissions_potential": 1.9, "energy_rating_potential": 63, "lighting_cost_potential": {"value": 26, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1629, "impact_of_loft_insulation": -2441, "impact_of_solid_wall_insulation": -2217, "space_heating_existing_dwelling": 7636}, "energy_consumption_current": 462, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 365, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 82, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100061573300, "roofs": [{"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 87% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR3 7EJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CATERHAM", "built_form": 1, "created_at": "2017-06-27 14:54:26", "door_count": 4, "glazed_area": 2, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17315}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17315}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Lunghurst Rise", "address_line_2": "Lunghurst Road", "address_line_3": "Woldingham", "assessment_type": "RdSAP", "completion_date": "2017-06-27", "inspection_date": "2017-06-21", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 455, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 12, "registration_date": "2017-06-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": [[{"pitch": 3, "peak_power": {"value": 4.8, "quantity": "kW"}, "orientation": 5, "overshading": 1, "pv_connection": 2}], [{"pitch": 1, "peak_power": {"value": 3.7, "quantity": "kW"}, "orientation": "ND", "overshading": 1, "pv_connection": 2}]], "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 373, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 104.11, "quantity": "square metres"}, "insulation": 3, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "50mm"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 123.77, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.4, "quantity": "metres"}, "total_floor_area": {"value": 128.43, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 45.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.34, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "100mm"}], "low_energy_lighting": 87, "solar_water_heating": "N", "habitable_room_count": 12, "heating_cost_current": {"value": 4275, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 19, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 164, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 3, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 2967, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 1094, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 64}], "co2_emissions_potential": 12, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 164, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 153, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3134, "impact_of_loft_insulation": -2014, "impact_of_solid_wall_insulation": -19213, "space_heating_existing_dwelling": 73861}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 140, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 52, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 45} +{"uprn": 100061787664, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RH11 0NL", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "CRAWLEY", "built_form": 1, "created_at": "2017-09-21 16:14:39", "door_count": 4, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Plough Close", "address_line_2": "Ifield", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.57, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 30.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 55.67, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1474, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 37, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 4, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 650, "currency": "GBP"}, "hot_water_cost_current": {"value": 248, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 41, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 398, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 59}, {"sequence": 8, "typical_saving": {"value": 195, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 69}, {"sequence": 9, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 10, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 11, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 114, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 338, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3624, "impact_of_loft_insulation": -490, "impact_of_cavity_insulation": -5545, "space_heating_existing_dwelling": 18925}, "energy_consumption_current": 438, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 30, "calculation_software_version": "9.0.0", "energy_consumption_potential": 120, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 32151504, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WS5 4BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WALSALL", "built_form": 4, "created_at": "2017-04-21 12:36:25.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2105, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16495}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "18, Greenside Way", "assessment_type": "RdSAP", "completion_date": "2017-04-21", "inspection_date": "2017-04-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 395, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.206, "quantity": "square metres"}, "party_wall_length": {"value": 12.64, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.958, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 420, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and at least two room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 329, "currency": "GBP"}, "hot_water_cost_current": {"value": 165, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.8, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2382, "space_heating_existing_dwelling": 4864}, "energy_consumption_current": 383, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 258, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 25024858, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK13 0ES", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "MILTON KEYNES", "built_form": 4, "created_at": "2017-04-21 14:22:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "73, Bridgeway", "address_line_2": "New Bradwell", "assessment_type": "RdSAP", "completion_date": "2017-04-21", "inspection_date": "2017-04-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 23, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-04-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.42, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 186, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 28, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 140, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 500, "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 68}], "co2_emissions_potential": 1.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 28, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 118, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1435, "space_heating_existing_dwelling": 1925}, "energy_consumption_current": 462, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 396, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10023889982, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 31% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TR19 7SB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "PENZANCE", "built_form": 1, "created_at": "2017-09-21 17:26:42", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10353}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "The Old Manse", "address_line_2": "Pendeen", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.09, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 63.09, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 180, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.78, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 31, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1362, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 37, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 891, "currency": "GBP"}, "hot_water_cost_current": {"value": 176, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 409, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 82}], "co2_emissions_potential": 2.3, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2305, "impact_of_solid_wall_insulation": -5567, "space_heating_existing_dwelling": 17229}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 84, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "F", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100110067249, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS10 1QS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "REDCAR", "built_form": 2, "created_at": "2017-09-21 18:51:19.000000", "door_count": 3, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16521}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Hornleigh Grove", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 134, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 21.66, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "N", "construction_age_band": "C", "roof_insulation_thickness": "150mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.01, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 29.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 51.89, "quantity": "square metres"}, "party_wall_length": {"value": 8.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.83, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1232, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 736, "currency": "GBP"}, "hot_water_cost_current": {"value": 248, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 381, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 270, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 424, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3375, "impact_of_loft_insulation": -268, "space_heating_existing_dwelling": 16230}, "energy_consumption_current": 310, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 125, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100030231491, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S21 5SA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 2, "created_at": "2017-08-22 14:08:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "11, Woodnook Grove", "address_line_2": "Marsh Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.39, "quantity": "square metres"}, "party_wall_length": {"value": 9.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.82, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.03, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 482, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 438, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1835, "space_heating_existing_dwelling": 6326}, "energy_consumption_current": 244, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 114, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45107760, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR4 0ES", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 03:58:21.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "41, Prescot Road", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 701, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 607, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2197, "space_heating_existing_dwelling": 9264}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 65, "calculation_software_version": "1.0.x", "energy_consumption_potential": 138, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100080363796, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SL6 2TU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 2, "created_at": "2017-07-21 12:57:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15445}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "34, Rixman Close", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-07-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.1, "quantity": "metres"}}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.786, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 69.96, "quantity": "square metres"}, "party_wall_length": {"value": 3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 601, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 494, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.8, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "impact_of_loft_insulation": -3835, "impact_of_cavity_insulation": -2783, "space_heating_existing_dwelling": 10604}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 224, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45097277, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR4 9SQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 3, "created_at": "2017-06-02 06:17:08", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "54, Gravesend Road", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-05-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 50}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 704, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 636, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.6, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2051, "space_heating_existing_dwelling": 10222}, "energy_consumption_current": 113, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "B", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 20, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100070255210, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV31 2PH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEAMINGTON SPA", "built_form": 2, "created_at": "2017-04-20 21:08:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "7, Stretton Crescent", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 480, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.07, "quantity": "square metres"}, "party_wall_length": {"value": 6.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.88, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 413, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 33, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 367, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1623, "space_heating_existing_dwelling": 5171}, "energy_consumption_current": 253, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 82, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200224601, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N12 8RT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-10-22 11:21:08.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8442}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "9 Woodside Park Road", "assessment_type": "RdSAP", "completion_date": "2017-10-22", "inspection_date": "2017-10-20", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.2, "quantity": "metres"}}, "total_floor_area": 106, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": 16.1, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.12, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.3, "quantity": "square metres"}, "party_wall_length": 9.26, "heat_loss_perimeter": {"value": 14.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 8, "roof_construction": 8, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 4.33, "quantity": "square metres"}, "party_wall_length": 2.41, "heat_loss_perimeter": {"value": 4.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1379, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 696, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 219, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 227, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 161, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}], "co2_emissions_potential": 3.8, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2256, "impact_of_loft_insulation": -5410, "impact_of_solid_wall_insulation": -4310, "space_heating_existing_dwelling": 22710}, "energy_consumption_current": 414, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 204, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 77094928, "roofs": [{"description": {"value": "Pitched, 400 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M16 8GJ", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 2, "created_at": "2017-10-20 20:47:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4020}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "75, Alexandra Road South", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 157, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.58, "quantity": "square metres"}, "party_wall_length": {"value": 10.01, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 70.58, "quantity": "square metres"}, "party_wall_length": {"value": 10.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.71, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.42, "quantity": "square metres"}, "party_wall_length": {"value": 5.57, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.34, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 958, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 712, "currency": "GBP"}, "hot_water_cost_current": {"value": 278, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 185, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 232, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4268, "impact_of_loft_insulation": -89, "space_heating_existing_dwelling": 14011}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 110, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 45003230, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SR2 9AT", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SUNDERLAND", "built_form": 1, "created_at": "2017-05-21 20:14:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31, Loughborough Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-21", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 134, "transaction_type": 9, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-05-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.32, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 71.74, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 34.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1178, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 152, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No time or thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 699, "currency": "GBP"}, "hot_water_cost_current": {"value": 256, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a385", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 384, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 291, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 207, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 421, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3469, "impact_of_loft_insulation": -917, "space_heating_existing_dwelling": 15457}, "energy_consumption_current": 312, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010959462, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BL8 1XW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURY", "built_form": 1, "created_at": "2017-09-20 17:49:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "90, Grantham Drive", "assessment_type": "RdSAP", "completion_date": "2017-09-20", "inspection_date": "2017-09-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.6, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.7, "quantity": "square metres"}, "party_wall_length": {"value": 5.74, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 47.7, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.26, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 869, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 760, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2243, "impact_of_loft_insulation": -390, "space_heating_existing_dwelling": 12639}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 164, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200002941908, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 94% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH7 6EA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MOLD", "built_form": 1, "created_at": "2017-09-20 19:40:25.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Woodlands", "address_line_2": "Main Road", "address_line_3": "Sychdyn", "assessment_type": "RdSAP", "completion_date": "2017-09-20", "inspection_date": "2017-09-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 177, "transaction_type": 11, "conservatory_type": 3, "heated_room_count": 10, "registration_date": "2017-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 87.81, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 41.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 89.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 94, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 919, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 919, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 4.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "space_heating_existing_dwelling": 15610}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 135, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 35, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 33} +{"uprn": 100080747789, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SG12 9HT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WARE", "built_form": 3, "created_at": "2017-04-20 22:51:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2703, "main_heating_category": 8, "main_heating_fraction": 1, "sap_main_heating_code": 421, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric underfloor heating", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "6, Broadmeads", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 69.01, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 454, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 138, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.9, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 278, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3324, "impact_of_cavity_insulation": -3700, "space_heating_existing_dwelling": 6429}, "energy_consumption_current": 448, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 247, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100021233126, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N15 4AT", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 6, "created_at": "2017-10-20 13:51:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "29 Tynemouth Road", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 3}, "total_floor_area": 18, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.5, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 280, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 18, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 135, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 20, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 45, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 83}], "co2_emissions_potential": 0.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 20, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 821, "impact_of_solid_wall_insulation": -268, "space_heating_existing_dwelling": 1555}, "energy_consumption_current": 424, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.13r13", "energy_consumption_potential": 238, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45133171, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SR1 2LA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-01 13:52:21.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "41 Lumley Tower", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 11, "heat_loss_corridor": 2, "unheated_corridor_length": 10.4}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.0, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 320, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 298, "currency": "GBP"}, "hot_water_cost_current": {"value": 203, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 140, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2351, "space_heating_existing_dwelling": 3590}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 153, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 200000125623, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SY5 9LB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SHREWSBURY", "built_form": 1, "created_at": "2017-08-16 11:57:17", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4153}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Southerly", "address_line_2": "Chavel, Ford", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-07-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 226, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 226.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 108.59, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1527, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 204, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1212, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 231, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}], "co2_emissions_potential": 6.4, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 102, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2921, "space_heating_existing_dwelling": 24806}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 129, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45115057, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR3 3DY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 3, "created_at": "2017-06-02 01:49:30.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "4, Aberdare Road", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3.9}, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.0, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 260, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.9, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 389, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 328, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1605, "space_heating_existing_dwelling": 4722}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 210, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 45101765, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR5 4QH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 3, "created_at": "2017-06-01 17:36:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "59, Bexhill Road", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 315, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 361, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1763, "space_heating_existing_dwelling": 6925}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 84, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100120690578, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WR11 7HS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EVESHAM", "built_form": 4, "created_at": "2017-04-28 10:10:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "12, Clayfield Road", "address_line_2": "Bretforton", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-03-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.6, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 27.6, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.28, "quantity": "square metres"}, "party_wall_length": {"value": 3.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 403, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 380, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1951, "impact_of_loft_insulation": -513, "space_heating_existing_dwelling": 5466}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 89, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10013545918, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL14 3PB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WREXHAM", "built_form": 2, "created_at": "2017-07-24 09:22:03.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Heol Craigfab", "address_line_2": "Cefn Mawr", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 35.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 587, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 457, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 142, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 167, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2507, "space_heating_existing_dwelling": 7242}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 118, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 45104952, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE38 7DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 3, "created_at": "2017-06-01 07:21:33.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 2, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "50, The Terraces", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.2, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.1, "quantity": "square metres"}, "party_wall_length": {"value": 1.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 448, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 375, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1600, "space_heating_existing_dwelling": 5988}, "energy_consumption_current": 284, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 97, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10006839061, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 69% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL7 5PQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CIRENCESTER", "built_form": 1, "created_at": "2017-04-20 15:32:01.000000", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8423}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "8, Dukes Field", "address_line_2": "Down Ampney", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 172, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 85.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 44.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 85.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 44.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 848, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 814, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2893, "space_heating_existing_dwelling": 14779}, "energy_consumption_current": 160, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 109, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 29, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 200001930706, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 15% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "RH16 1BQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HAYWARDS HEATH", "built_form": 3, "created_at": "2017-06-20 16:16:33.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 4033}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 22 Charter Gate", "address_line_2": "Boltro Road", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-06-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.65}, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.513, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 32.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 15, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 398, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 331, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 121, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2630, "space_heating_existing_dwelling": 5265}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 157, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100062391116, "roofs": [{"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME4 4EN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHATHAM", "built_form": 2, "created_at": "2017-09-20 17:14:25.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16374}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "21e, High Street", "assessment_type": "RdSAP", "completion_date": "2017-09-20", "inspection_date": "2017-09-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": {"value": 33.868, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "C", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.806, "quantity": "metres"}, "total_floor_area": {"value": 18.555, "quantity": "square metres"}, "party_wall_length": {"value": 6.082, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.172, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 780, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 595, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}], "co2_emissions_potential": 3.2, "energy_rating_potential": 58, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1803, "impact_of_solid_wall_insulation": -1212, "space_heating_existing_dwelling": 13591}, "energy_consumption_current": 447, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 344, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 53, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 45099322, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE37 2RE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 4, "created_at": "2017-06-01 09:58:57.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Don Gardens", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 484, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 384, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2026, "space_heating_existing_dwelling": 7859}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 81, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45114168, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SR5 4EY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 3, "created_at": "2017-06-01 18:24:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Bootle Street", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.7, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 25.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 500, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1781, "impact_of_loft_insulation": -229, "space_heating_existing_dwelling": 6644}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 107, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100090320144, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO9 3PT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HALSTEAD", "built_form": 2, "created_at": "2017-04-20 20:16:22.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1965}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "178, Swan Street", "address_line_2": "Sible Hedingham", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 38.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 944, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 478, "currency": "GBP"}, "hot_water_cost_current": {"value": 185, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 10, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3171, "impact_of_loft_insulation": -334, "impact_of_solid_wall_insulation": -5500, "space_heating_existing_dwelling": 13789}, "energy_consumption_current": 400, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010545117, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PR1 5HE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRESTON", "built_form": 4, "created_at": "2017-04-20 20:41:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15200}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "207, Fletcher Road", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 56, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 304, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 28, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 580, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 498, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1796, "impact_of_loft_insulation": -2447, "impact_of_cavity_insulation": -1270, "space_heating_existing_dwelling": 8725}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 159, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031559003, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG5 4DH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2017-04-20 15:49:52.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 3, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9586}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "17, Hood Street", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.65, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 37.55, "quantity": "square metres"}, "party_wall_length": {"value": 6.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 742, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 418, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2077, "impact_of_solid_wall_insulation": -5993, "space_heating_existing_dwelling": 13114}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 89, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100011777146, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 13% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "WN4 9HJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIGAN", "built_form": 2, "created_at": "2017-08-29 15:51:03.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "22, Glebe Avenue", "address_line_2": "Ashton-in-Makerfield", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.79, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 29.79, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.72, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 463, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 396, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1677, "space_heating_existing_dwelling": 6153}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 86, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 200001159729, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WS14 0AB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LICHFIELD", "built_form": 1, "created_at": "2017-09-29 11:19:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Redlock Field", "assessment_type": "RdSAP", "completion_date": "2017-09-29", "inspection_date": "2017-09-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 572, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 500, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2019, "space_heating_existing_dwelling": 8911}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 126, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100041097503, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH2 5RT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOURNEMOUTH", "built_form": 4, "created_at": "2017-06-29 14:36:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10124}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "67a Commercial Road", "assessment_type": "RdSAP", "completion_date": "2017-06-29", "inspection_date": "2017-06-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 3.5}, "total_floor_area": 19, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.695, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 18.55, "quantity": "square metres"}, "party_wall_length": {"value": 10.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 254, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 18, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 184, "currency": "GBP"}, "hot_water_cost_current": {"value": 68, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 81}], "co2_emissions_potential": 0.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 18, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1336, "impact_of_solid_wall_insulation": -734, "space_heating_existing_dwelling": 2602}, "energy_consumption_current": 367, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.11r11", "energy_consumption_potential": 259, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100100679330, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NP20 2BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWPORT", "built_form": 3, "created_at": "2017-06-29 15:54:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "4, New Ruperra Street", "assessment_type": "RdSAP", "completion_date": "2017-06-29", "inspection_date": "2017-06-29", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 43, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.9, "quantity": "square metres"}, "party_wall_length": {"value": 11.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.09, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.4, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 394, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 287, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.5, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1680, "impact_of_loft_insulation": -680, "impact_of_cavity_insulation": -333, "impact_of_solid_wall_insulation": -1259, "space_heating_existing_dwelling": 5512}, "energy_consumption_current": 266, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 195, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100021397519, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM3 0LU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROMFORD", "built_form": 2, "created_at": "2017-06-29 17:14:19.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "142, Squirrels Heath Road", "assessment_type": "RdSAP", "completion_date": "2017-06-29", "inspection_date": "2017-06-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.97, "quantity": "square metres"}, "party_wall_length": {"value": 6.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 36.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.39, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 746, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 348, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2045, "impact_of_solid_wall_insulation": -5343, "space_heating_existing_dwelling": 11105}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 61, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100040244244, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX32 9JN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNSTAPLE", "built_form": 4, "created_at": "2017-09-29 19:22:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "58, Broadfield Road", "assessment_type": "RdSAP", "completion_date": "2017-09-29", "inspection_date": "2017-09-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.83, "quantity": "square metres"}, "party_wall_length": {"value": 13.24, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.94, "quantity": "square metres"}, "party_wall_length": {"value": 13.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 388, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2068, "impact_of_cavity_insulation": -1766, "space_heating_existing_dwelling": 7895}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100021494354, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "UB8 3ST", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UXBRIDGE", "built_form": 1, "created_at": "2017-07-22 16:01:34.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "78, St. Clement Close", "assessment_type": "RdSAP", "completion_date": "2017-07-22", "inspection_date": "2017-07-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 158, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-07-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 52.5, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "F"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 105.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 43, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 893, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 658, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2324, "impact_of_loft_insulation": -1226, "space_heating_existing_dwelling": 17070}, "energy_consumption_current": 181, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 101, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 90914, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BS15 8BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2017-05-23 16:01:20.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17741}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "1, St. Michaels Court", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.9, "quantity": "metres"}}, "total_floor_area": 47, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.7, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 279, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.26, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 377, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 293, "currency": "GBP"}, "hot_water_cost_current": {"value": 76, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1594, "impact_of_cavity_insulation": -376, "space_heating_existing_dwelling": 4547}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 171, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100020224279, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA8 3AZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ERITH", "built_form": 2, "created_at": "2017-09-28 16:31:45.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "158, Avenue Road", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 56, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 495, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2804, "space_heating_existing_dwelling": 8859}, "energy_consumption_current": 171, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 92, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 128036576, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, with additional insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT6 6LA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "SURBITON", "built_form": 3, "created_at": "2017-06-23 16:14:29.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 7 Ravens Ait Hall", "address_line_2": "22-24, Kingsdowne Road", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-22", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.22, "quantity": "metres"}}, "total_floor_area": 83, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.1422, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 180, "wall_construction": 5, "wall_insulation_type": 3, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 52.82, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 31.24, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "total_floor_area": {"value": 29.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 427, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 383, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2380, "impact_of_loft_insulation": -939, "space_heating_existing_dwelling": 6678}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100040576351, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH23 1DD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHRISTCHURCH", "built_form": 2, "created_at": "2017-09-22 17:54:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 Harbour View Court", "address_line_2": "Princess Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.31, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 358, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 223, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2448, "impact_of_cavity_insulation": -899, "space_heating_existing_dwelling": 4026}, "energy_consumption_current": 306, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 162, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 422000127403, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OL1 3PA", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "OLDHAM", "built_form": 5, "created_at": "2017-09-25 23:10:14.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "185b Huddersfield Road", "assessment_type": "RdSAP", "completion_date": "2017-09-25", "inspection_date": "2017-09-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.14, "quantity": "metres"}}, "total_floor_area": 21, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-09-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.55, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.79, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 20.65, "quantity": "square metres"}, "party_wall_length": {"value": 9.13, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 9.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 533, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 192, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 828, "impact_of_solid_wall_insulation": -1105, "space_heating_existing_dwelling": 3427}, "energy_consumption_current": 651, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 478, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 110, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 2465017405, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "System built, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "addendum_numbers": [1]}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LE3 1GP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-09-22 15:09:36.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "3, Mortimer Place", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.42, "quantity": "square metres"}, "party_wall_length": {"value": 6.21, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.45, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 70, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.39, "quantity": "square metres"}, "party_wall_length": {"value": 1.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 369, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1871, "impact_of_loft_insulation": -630, "space_heating_existing_dwelling": 6614}, "energy_consumption_current": 324, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 118, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100091145474, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "IP13 0RD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOODBRIDGE", "built_form": 3, "created_at": "2017-08-22 16:05:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5902}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "171, High Street", "address_line_2": "Wickham Market", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 27, "quantity": "square metres"}, "party_wall_length": {"value": 4.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.3, "quantity": "square metres"}, "party_wall_length": 5.1, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 786, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 345, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 8, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 9, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 95, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2620, "impact_of_loft_insulation": -147, "impact_of_solid_wall_insulation": -4761, "space_heating_existing_dwelling": 12024}, "energy_consumption_current": 446, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 70, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 207178467, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N13 4RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-08-22 15:44:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15701}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 New Park House", "address_line_2": "Aldermans Hill", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-22", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": {"value": 22.1, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 47.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.9, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.6, "quantity": "square metres"}, "party_wall_length": {"value": 10.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 645, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 507, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.8, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 101, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2050, "impact_of_loft_insulation": -1950, "impact_of_solid_wall_insulation": -3227, "space_heating_existing_dwelling": 11340}, "energy_consumption_current": 273, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 214, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100021975222, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"addendum_numbers": [9], "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 35% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SE13 7UT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2017-06-23 08:35:02.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8100}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8100}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "57, Ladywell Road", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 177, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.89, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 73.89, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 34.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 35, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2049, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 144, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 762, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 40, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 36}, {"sequence": 3, "typical_saving": {"value": 583, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}, {"sequence": 7, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 236, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 9, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 10, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 108, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2335, "impact_of_loft_insulation": -333, "impact_of_cavity_insulation": -1786, "impact_of_solid_wall_insulation": -9606, "space_heating_existing_dwelling": 32735}, "energy_consumption_current": 356, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "9.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 32, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100110237335, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 90% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CA14 5BU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORKINGTON", "built_form": 4, "created_at": "2017-06-23 08:01:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "18, Richmond Road", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.16, "quantity": "square metres"}, "party_wall_length": {"value": 12.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 42.16, "quantity": "square metres"}, "party_wall_length": {"value": 12.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 656, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 502, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2288, "impact_of_cavity_insulation": -2360, "space_heating_existing_dwelling": 10285}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 113, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100007598, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RM10 7UD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAGENHAM", "built_form": 2, "created_at": "2017-06-22 13:57:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "752, Dagenham Road", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.04, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.23, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 240, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 63.02, "quantity": "square metres"}, "party_wall_length": {"value": 1.81, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 709, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 527, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 185, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.8, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1979, "impact_of_loft_insulation": -4878, "impact_of_solid_wall_insulation": -4605, "space_heating_existing_dwelling": 12631}, "energy_consumption_current": 346, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 255, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 49009952, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA44 4HS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "LLANDYSUL", "built_form": 2, "created_at": "2017-06-22 20:10:29", "door_count": 2, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2204, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 102606}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Air source heat pump, radiators, electric", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "28, The Beeches", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.14, "quantity": "square metres"}, "party_wall_length": {"value": 6.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 37.14, "quantity": "square metres"}, "party_wall_length": {"value": 6.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.22, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 450, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 361, "currency": "GBP"}, "hot_water_cost_current": {"value": 259, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 175, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2745, "space_heating_existing_dwelling": 7472}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 80, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100030507571, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LE10 0YQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HINCKLEY", "built_form": 1, "created_at": "2017-06-22 18:05:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1838}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "3, Odstone Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.61, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 461, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1742, "impact_of_loft_insulation": -318, "space_heating_existing_dwelling": 7212}, "energy_consumption_current": 273, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10093621784, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N7 6RT", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-05-31 17:55:58.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Rear Ground Floor Flat", "address_line_2": "13 Sussex Way", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-05-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 18, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.45, "quantity": "square metres"}, "party_wall_length": {"value": 4.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.01, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 205, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 20, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 145, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "co2_emissions_potential": 1.4, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 20, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 141, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 822, "space_heating_existing_dwelling": 2427}, "energy_consumption_current": 560, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 438, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 95, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100110327696, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CA10 2EN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PENRITH", "built_form": 1, "created_at": "2017-09-28 15:52:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8278}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "16, Cumberland Close", "address_line_2": "Clifton", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 84.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.79, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.49, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 699, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 595, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 2.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 126, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2798, "space_heating_existing_dwelling": 10438}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.13r09", "energy_consumption_potential": 132, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100031368784, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG4 4WB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2017-04-27 13:00:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15017}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "39, Lorimer Avenue", "address_line_2": "Gedling", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.68, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 357, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 330, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2911, "space_heating_existing_dwelling": 5013}, "energy_consumption_current": 251, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 81, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10094363566, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Granite or whinstone, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LL55 3HR", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "CAERNARFON", "built_form": 2, "created_at": "2017-08-29 18:15:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3, The Old Post Office", "address_line_2": "High Street", "address_line_3": "Deiniolen", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 34, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.76, "wall_dry_lined": "N", "wall_thickness": 700, "wall_construction": 1, "wall_insulation_type": 3, "wall_thickness_measured": "Y", "wall_insulation_thickness": "50mm"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 33.705, "quantity": "square metres"}, "party_wall_length": {"value": 3.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 766, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 229, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 366, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.0, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 269, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 256, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 156, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 900, "impact_of_solid_wall_insulation": -2332, "space_heating_existing_dwelling": 4876}, "energy_consumption_current": 556, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 344, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 94, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100021474024, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "UB10 8UN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UXBRIDGE", "built_form": 2, "created_at": "2017-09-27 14:34:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8531}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "104, Aylsham Drive", "address_line_2": "Ickenham", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.18, "quantity": "metres"}}, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.21, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 61.17, "quantity": "square metres"}, "party_wall_length": {"value": 3.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 370, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 274, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2412, "impact_of_loft_insulation": -706, "space_heating_existing_dwelling": 4998}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 153, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100080766677, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 61% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WD6 3HN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOREHAMWOOD", "built_form": 2, "created_at": "2017-08-29 10:08:21.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Rodgers Close", "address_line_2": "Elstree", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.84, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 30.84, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 61, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 429, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 315, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 6, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1722, "impact_of_loft_insulation": -466, "space_heating_existing_dwelling": 6849}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 50, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100070489985, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 35% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B17 9TB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-04-28 12:02:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Ravenhurst Road", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 187, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 42.84, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 60.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 35, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2115, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 149, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1692, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 334, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3100", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}], "co2_emissions_potential": 7.4, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2465, "impact_of_loft_insulation": -1583, "impact_of_solid_wall_insulation": -5874, "space_heating_existing_dwelling": 34745}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 226, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 31, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100051069835, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S2 5EQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 3, "created_at": "2017-09-27 19:58:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "4, Saunders Road", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 56, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.96, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 28.12, "quantity": "square metres"}, "party_wall_length": {"value": 6.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 382, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 354, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1798, "space_heating_existing_dwelling": 5819}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 90, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100090585499, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 10% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SS6 8QN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RAYLEIGH", "built_form": 1, "created_at": "2017-10-27 09:43:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 3, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10459}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "true", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "44, The Chase", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 213, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 92.01, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 121.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 54.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1259, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 193, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1273, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 1, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": 425, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "co2_emissions_potential": 5.2, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 101, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 133, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2786, "space_heating_existing_dwelling": 14170}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "true", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 140, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 94, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100061759923, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU27 3QZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HASLEMERE", "built_form": 4, "created_at": "2017-09-30 12:23:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "79, Hammer Hill", "assessment_type": "RdSAP", "completion_date": "2017-09-30", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.47, "quantity": "square metres"}, "party_wall_length": {"value": 12.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 302, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 275, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.3, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1522, "space_heating_existing_dwelling": 4123}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 39, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10007894274, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M3 7DY", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SALFORD", "built_form": 4, "created_at": "2017-09-29 09:32:34.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Apartment 319 Quebec Building", "address_line_2": "Bury Street", "assessment_type": "RdSAP", "completion_date": "2017-09-29", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 9.2}, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.712, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 58.9, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 413, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 193, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 284, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 259, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 140, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1913, "space_heating_existing_dwelling": 2938}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 275, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 5030817, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WC1R 4AP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-09-24 15:22:11.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 17501}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 18 Beckley", "address_line_2": "Eagle Street", "assessment_type": "RdSAP", "completion_date": "2017-09-24", "inspection_date": "2017-06-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 51.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 275, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 183, "currency": "GBP"}, "hot_water_cost_current": {"value": 74, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 86}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1601, "impact_of_cavity_insulation": -2037, "space_heating_existing_dwelling": 3857}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 111, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 77056520, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "M22 5RZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2017-07-27 18:03:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 64 Birch Tree Court", "address_line_2": "Rowlandsway", "assessment_type": "RdSAP", "completion_date": "2017-07-27", "inspection_date": "2017-07-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 5, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 47.99, "quantity": "square metres"}, "party_wall_length": {"value": 17.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 230, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 233, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1669, "space_heating_existing_dwelling": 2517}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100061114257, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 11% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CT10 1NL", "hot_water": {"description": "Gas instantaneous at point of use", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BROADSTAIRS", "built_form": 2, "created_at": "2017-04-28 04:58:08.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 907, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "10, Pierremont Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-27", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 162, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.95, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 46.95, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.61, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 27.47, "quantity": "square metres"}, "party_wall_length": {"value": 7.61, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.13, "quantity": "square metres"}, "party_wall_length": {"value": 1.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 6.13, "quantity": "square metres"}, "party_wall_length": {"value": 1.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 3035, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 16, "energy_rating_average": 60, "energy_rating_current": 24, "lighting_cost_current": {"value": 157, "currency": "GBP"}, "main_heating_controls": [{"description": "No time or thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1242, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 405, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 24}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 26}, {"sequence": 3, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 27}, {"sequence": 4, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 80, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 28}, {"sequence": 5, "typical_saving": {"value": 481, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 36}, {"sequence": 6, "typical_saving": {"value": 614, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 51}, {"sequence": 7, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 8, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 60}], "co2_emissions_potential": 5.7, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 33, "environmental_impact_rating": 26}, {"sequence": 2, "typical_saving": {"value": 275, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 49, "environmental_impact_rating": 86}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 47, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 734, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 53}], "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1468, "impact_of_loft_insulation": -5775, "impact_of_cavity_insulation": -5644, "space_heating_existing_dwelling": 35397}, "energy_consumption_current": 562, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.11r09", "energy_consumption_potential": 198, "environmental_impact_current": 18, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "F", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 99, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100090344828, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CM13 2DG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRENTWOOD", "built_form": 3, "created_at": "2017-10-27 15:52:07.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "72, Running Waters", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 462, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 427, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2026, "impact_of_loft_insulation": -571, "space_heating_existing_dwelling": 7118}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 98, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090583974, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SS6 8SR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RAYLEIGH", "built_form": 1, "created_at": "2017-05-27 10:41:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17682}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "19, Oakhurst Road", "assessment_type": "RdSAP", "completion_date": "2017-05-27", "inspection_date": "2017-05-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 216, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-05-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 89.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 87.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 39.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 652, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 652, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 101, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2441, "space_heating_existing_dwelling": 11514}, "energy_consumption_current": 99, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 72, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "B", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 17, "low_energy_fixed_lighting_outlets_count": 26} +{"uprn": 100070301455, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 79% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B42 2RH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2017-05-04 16:49:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1711}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "10, Bowman Road", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-04-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 18.01, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "I"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.69, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 35.23, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.31, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 780, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 617, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 107, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "impact_of_loft_insulation": -2156, "space_heating_existing_dwelling": 11628}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r10", "energy_consumption_potential": 143, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 518751, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true", "addendum_numbers": [1]}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS16 4RP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2017-08-24 16:43:14.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "197, Soundwell Road", "assessment_type": "RdSAP", "completion_date": "2017-08-24", "inspection_date": "2017-08-24", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 2.85, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 3.63}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 25.76, "wall_dry_lined": "N", "wall_thickness": 450, "wall_construction": 2, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.49, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 39.19, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.53, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.01, "quantity": "metres"}, "total_floor_area": {"value": 10.53, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 180, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.18, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1401, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 886, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 462, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 62}], "co2_emissions_potential": 3.7, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2391, "impact_of_loft_insulation": -4155, "impact_of_solid_wall_insulation": -8515, "space_heating_existing_dwelling": 23360}, "energy_consumption_current": 386, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 184, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10007061022, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU2 9LB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GUILDFORD", "built_form": 1, "created_at": "2017-04-25 20:57:22.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9896}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Michael Lane", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.87, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 42.28, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 4.09, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "J"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.62, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 408, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2577, "space_heating_existing_dwelling": 6286}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 73, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100031655339, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE14 3JQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURTON-ON-TRENT", "built_form": 3, "created_at": "2017-08-24 15:48:39.000000", "door_count": 2, "glazed_area": 4, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "true", "glazing_gap": 12, "orientation": 8, "window_area": {"value": 2.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 4, "window_area": {"value": 1.26, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 1.57, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 2.16, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "31, Cotswold Road", "address_line_2": "Branston", "assessment_type": "RdSAP", "completion_date": "2017-08-24", "inspection_date": "2017-08-24", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.07, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.89, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 492, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 420, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1686, "space_heating_existing_dwelling": 6678}, "energy_consumption_current": 263, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 106, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10024226286, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE65 5LR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 1, "created_at": "2017-10-24 19:54:30.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18041}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Orwell Road", "address_line_2": "Hilton", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 50.82, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.95, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 404, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 407, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.3, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2362, "space_heating_existing_dwelling": 6385}, "energy_consumption_current": 121, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 62, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100090346657, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CM14 5JQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRENTWOOD", "built_form": 4, "created_at": "2017-05-25 22:36:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15751}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Sussex Road", "address_line_2": "Warley", "assessment_type": "RdSAP", "completion_date": "2017-05-25", "inspection_date": "2017-05-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.77, "quantity": "square metres"}, "party_wall_length": {"value": 14.32, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 22.77, "quantity": "square metres"}, "party_wall_length": {"value": 14.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.9, "quantity": "square metres"}, "party_wall_length": 3.56, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 537, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 447, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1772, "impact_of_loft_insulation": -1951, "impact_of_cavity_insulation": -569, "impact_of_solid_wall_insulation": -798, "space_heating_existing_dwelling": 9028}, "energy_consumption_current": 304, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 126, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200004507350, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BB3 1HJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DARWEN", "built_form": 4, "created_at": "2017-07-24 18:43:02.000000", "door_count": 3, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1920}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Pitville Street", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 36.27, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "K", "roof_insulation_thickness": "300mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.14, "quantity": "square metres"}, "party_wall_length": {"value": 11.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 23.14, "quantity": "square metres"}, "party_wall_length": {"value": 11.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.72, "quantity": "square metres"}, "party_wall_length": 5.22, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 596, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 596, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2220, "space_heating_existing_dwelling": 8333}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 127, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100080380657, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL4 5SS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WINDSOR", "built_form": 2, "created_at": "2017-08-24 19:17:22.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10459}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "44, Redford Road", "assessment_type": "RdSAP", "completion_date": "2017-08-24", "inspection_date": "2017-08-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 122, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-08-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.1, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 43.1, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14, "quantity": "square metres"}, "party_wall_length": {"value": 3.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 14, "quantity": "square metres"}, "party_wall_length": {"value": 3.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1053, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 696, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2820, "impact_of_loft_insulation": -493, "impact_of_cavity_insulation": -4808, "space_heating_existing_dwelling": 17462}, "energy_consumption_current": 281, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 133, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 33, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 29} +{"uprn": 250064083, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"access_issues": "true", "high_exposure": "true", "narrow_cavities": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BA6 9FD", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "GLASTONBURY", "built_form": 4, "created_at": "2017-07-24 19:10:22.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 408, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "10 Cavendish Lodge", "address_line_2": "Magdalene Street", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1, "unheated_corridor_length": 0}, "total_floor_area": 44, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.68, "quantity": "square metres"}, "party_wall_length": {"value": 18.88, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 139, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 131, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1643, "space_heating_existing_dwelling": 1351}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 225, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100061456144, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH6 7NZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORLEY", "built_form": 3, "created_at": "2017-08-24 22:10:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "83, The Crescent", "assessment_type": "RdSAP", "completion_date": "2017-08-24", "inspection_date": "2017-08-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 69.29, "quantity": "square metres"}, "party_wall_length": {"value": 8.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.31, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 292, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2043, "space_heating_existing_dwelling": 3879}, "energy_consumption_current": 140, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 140, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040735869, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH11 8HP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOURNEMOUTH", "built_form": 2, "created_at": "2017-07-24 14:28:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "36, Frost Road", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.16, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 32.96, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.38, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 411, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 337, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "impact_of_loft_insulation": -190, "space_heating_existing_dwelling": 6007}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 56, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100010532652, "roofs": [{"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PR2 9UB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRESTON", "built_form": 2, "created_at": "2017-05-09 14:54:12.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8358}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "13, Ashwood Road", "address_line_2": "Fulwood", "assessment_type": "RdSAP", "completion_date": "2017-05-09", "inspection_date": "2017-04-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 122, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-05-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 48.55, "quantity": "square metres"}, "insulation": "NI", "roof_room_connected": "N", "construction_age_band": "D", "roof_insulation_thickness": "50mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.46, "quantity": "square metres"}, "party_wall_length": {"value": 9.12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.18, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1373, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 124, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 918, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 194, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 8, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "co2_emissions_potential": 4.0, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 243, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2292, "impact_of_loft_insulation": -246, "impact_of_cavity_insulation": -1101, "space_heating_existing_dwelling": 20421}, "energy_consumption_current": 355, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 183, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10090641649, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WV14 8BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BILSTON", "built_form": 1, "created_at": "2017-06-27 15:33:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17856}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "60a Humphries Crescent", "assessment_type": "RdSAP", "completion_date": "2017-06-27", "inspection_date": "2017-06-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.99, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 381, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 381, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2100, "space_heating_existing_dwelling": 5185}, "energy_consumption_current": 162, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100091018759, "roofs": [{"description": "Pitched, 25 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 94% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP27 0AQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRANDON", "built_form": 4, "created_at": "2017-04-24 19:03:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17663}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "25, High Street", "assessment_type": "RdSAP", "completion_date": "2017-04-24", "inspection_date": "2017-04-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.36, "quantity": "square metres"}, "party_wall_length": {"value": 22, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 52.53, "quantity": "square metres"}, "party_wall_length": {"value": 21.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.69, "quantity": "square metres"}, "party_wall_length": {"value": 4.37, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 120, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 94, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 877, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 534, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 176, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2152, "impact_of_loft_insulation": -2436, "impact_of_solid_wall_insulation": -3742, "space_heating_existing_dwelling": 16203}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 45, "calculation_software_version": "2.11r09", "energy_consumption_potential": 89, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 23013421, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M24 1GB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 2, "created_at": "2017-05-05 13:00:11.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "44, Banbury Road", "address_line_2": "Middleton", "assessment_type": "RdSAP", "completion_date": "2017-05-05", "inspection_date": "2017-04-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 130, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 25, "insulation": 0, "roof_room_connected": "Y", "construction_age_band": "G", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 14.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 886, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 774, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2042, "impact_of_loft_insulation": -1108, "impact_of_cavity_insulation": -1526, "space_heating_existing_dwelling": 16548}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r10", "energy_consumption_potential": 147, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 100051114840, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S6 5LW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2017-10-24 16:15:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "49, Woodfarm Drive", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 37.39, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 37.45, "quantity": "square metres"}, "party_wall_length": {"value": 16.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 1, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.1, "quantity": "square metres"}, "party_wall_length": {"value": 2.26, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 601, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 606, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 83, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}], "co2_emissions_potential": 3.4, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1871, "space_heating_existing_dwelling": 10692}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 240, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200002638535, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Granite or whinstone, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LL59 5BW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "MENAI BRIDGE", "built_form": 2, "created_at": "2017-05-24 13:22:11.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Mount Street", "assessment_type": "RdSAP", "completion_date": "2017-05-24", "inspection_date": "2017-05-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 480, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 34.61, "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 3, "wall_insulation_type": 1, "wall_thickness_measured": "Y", "wall_insulation_thickness": "50mm"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.75, "quantity": "square metres"}, "party_wall_length": {"value": 4.96, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 52.75, "quantity": "square metres"}, "party_wall_length": {"value": 4.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.86, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "50mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.12, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.74, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.26, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "50mm", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 710, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 609, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 92, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2500, "space_heating_existing_dwelling": 10054}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100011636511, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WA15 8JZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ALTRINCHAM", "built_form": 2, "created_at": "2017-04-25 18:48:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17115}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "116, Old Meadow Lane", "address_line_2": "Hale", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 8.38, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": 7.76}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.56, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.71, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 42.11, "quantity": "square metres"}, "party_wall_length": {"value": 6.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 140, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 816, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 707, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1976, "impact_of_loft_insulation": -1119, "impact_of_solid_wall_insulation": -593, "space_heating_existing_dwelling": 12240}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 145, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100062182226, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN17 5NZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}, "post_town": "LITTLEHAMPTON", "built_form": 4, "created_at": "2017-10-26 10:46:45.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 107, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat B", "address_line_2": "12, South Terrace", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 9.14}, "total_floor_area": 39, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.108, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 39.3, "quantity": "square metres"}, "party_wall_length": {"value": 9.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 333, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 183, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 84}], "co2_emissions_potential": 0.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1536, "impact_of_solid_wall_insulation": -657, "space_heating_existing_dwelling": 3367}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.13r13", "energy_consumption_potential": 137, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 72376995, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LS26 0HD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 2, "created_at": "2017-09-25 12:26:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10363}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Sixth Avenue", "address_line_2": "Rothwell", "assessment_type": "RdSAP", "completion_date": "2017-09-25", "inspection_date": "2017-09-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.5, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 38.5, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 611, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 557, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2081, "impact_of_loft_insulation": -3444, "space_heating_existing_dwelling": 10922}, "energy_consumption_current": 263, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 148, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100071251668, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 81% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV8 1PB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "KENILWORTH", "built_form": 1, "created_at": "2017-10-25 14:11:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17504}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Oldlydd", "address_line_2": "Red Lane", "address_line_3": "Burton Green", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 163, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 43.56, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "C"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.68, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 12, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 81, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 2116, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 27, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1077, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 664, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.4, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 102, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2250, "impact_of_loft_insulation": -183, "impact_of_solid_wall_insulation": -3175, "space_heating_existing_dwelling": 27263}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 91, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "F", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 100061119160, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT9 2BS", "hot_water": {"description": {"value": "Gas instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARGATE", "built_form": 4, "created_at": "2017-05-04 07:32:31.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 907, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 601, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Brockley Road", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 293, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.82, "quantity": "square metres"}, "party_wall_length": {"value": 15.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32.82, "quantity": "square metres"}, "party_wall_length": {"value": 15.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 781, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 345, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 103, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1196, "impact_of_solid_wall_insulation": -2545, "space_heating_existing_dwelling": 8231}, "energy_consumption_current": 354, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 60, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 39086907, "roofs": [{"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "WA11 0TE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. HELENS", "built_form": 2, "created_at": "2017-10-25 17:22:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16814}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "9, Orchard Court", "address_line_2": "Haydock", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 2.53}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.1985, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 45.34, "quantity": "square metres"}, "party_wall_length": {"value": 3.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 279, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1558, "space_heating_existing_dwelling": 2681}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 157, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 200000747438, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BA22 9SZ", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "YEOVIL", "built_form": 1, "created_at": "2017-10-25 16:12:26", "door_count": 4, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8431}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Hill View", "address_line_2": "Closworth Road", "address_line_3": "Halstock", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 38}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.62, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.36, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 576, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 211, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 78}, {"sequence": 7, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 80}, {"sequence": 8, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 107, "environmental_impact_rating": 98}], "co2_emissions_potential": -0.4, "energy_rating_potential": 107, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4070, "space_heating_existing_dwelling": 9200}, "energy_consumption_current": 107, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": -89, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 98, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100071095525, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WS9 0HH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALSALL", "built_form": 2, "created_at": "2017-08-25 14:11:14.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "256, Whetstone Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.49, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 42.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.55, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 445, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2843, "space_heating_existing_dwelling": 8374}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 99, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 5870059214, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SM5 1EE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARSHALTON", "built_form": 4, "created_at": "2017-08-25 15:08:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15834}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Peterborough Road", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.03, "quantity": "square metres"}, "party_wall_length": {"value": 12.78, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 26.52, "quantity": "square metres"}, "party_wall_length": {"value": 12.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.31, "quantity": "square metres"}, "party_wall_length": {"value": 3.18, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 384, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 329, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.7, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1841, "impact_of_loft_insulation": -376, "space_heating_existing_dwelling": 5670}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 46, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 65, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100062435755, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 76% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO36 9ND", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "SANDOWN", "built_form": 1, "created_at": "2017-08-25 13:14:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "5, Carpenter Close", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.38, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 35.32, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 76, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 555, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 331, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2306, "space_heating_existing_dwelling": 7162}, "energy_consumption_current": 244, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 108, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100040050195, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TR4 8LT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "TRURO", "built_form": 2, "created_at": "2017-04-25 18:45:39.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, The Terrace", "address_line_2": "Chacewater", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.25, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.54, "quantity": "metres"}, "total_floor_area": {"value": 45.25, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.68, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1739, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 13, "energy_rating_average": 60, "energy_rating_current": 27, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 586, "currency": "GBP"}, "hot_water_cost_current": {"value": 293, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 12}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 14}, {"sequence": 3, "typical_saving": {"value": 506, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 28}, {"sequence": 4, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 31}, {"sequence": 5, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 33}, {"sequence": 6, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 33}, {"sequence": 7, "typical_saving": {"value": 347, "currency": "GBP"}, "indicative_cost": "\u00a32,000 - \u00a33,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 41}, {"sequence": 8, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 44}, {"sequence": 9, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 51}, {"sequence": 10, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 58}], "co2_emissions_potential": 3.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 48, "environmental_impact_rating": 28}, {"sequence": 2, "typical_saving": {"value": 405, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 88}, {"sequence": 3, "typical_saving": {"value": 401, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2113, "impact_of_cavity_insulation": -1009, "impact_of_solid_wall_insulation": -6260, "space_heating_existing_dwelling": 21528}, "energy_consumption_current": 705, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 206, "environmental_impact_current": 10, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "F", "environmental_impact_potential": 58, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 124, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100012556906, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BL2 5DY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 1, "created_at": "2017-10-02 14:15:18.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "117, Withins Lane", "assessment_type": "RdSAP", "completion_date": "2017-10-02", "inspection_date": "2017-09-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 125, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-10-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.89, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 60.48, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 872, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 771, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 251, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2297, "space_heating_existing_dwelling": 15505}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 151, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100080934200, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 9% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WD19 4ST", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WATFORD", "built_form": 2, "created_at": "2017-08-25 17:19:10.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8070}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, St. Matthews Close", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.75, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 51.84, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 9, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 666, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 514, "currency": "GBP"}, "hot_water_cost_current": {"value": 204, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 88, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 132, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3302, "impact_of_loft_insulation": -333, "space_heating_existing_dwelling": 9670}, "energy_consumption_current": 250, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 100, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100051135472, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "addendum_numbers": [6]}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD14 6LQ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRADFORD", "built_form": 6, "created_at": "2017-04-25 16:07:19.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 2", "address_line_2": "37 Beaconsfield Road", "address_line_3": "Clayton", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-25", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 46, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 36.43, "quantity": "square metres"}, "party_wall_length": {"value": 12.61, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 9.76, "quantity": "square metres"}, "party_wall_length": {"value": 6.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 232, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 132, "currency": "GBP"}, "hot_water_cost_current": {"value": 243, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 208, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 250, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 237, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1564, "impact_of_solid_wall_insulation": -691, "space_heating_existing_dwelling": 1493}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 205, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 38080149, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "L18 9TY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2017-04-25 19:10:32.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "24a, Hurstlyn Road", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.67, "quantity": "metres"}}, "total_floor_area": 30, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.5682, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 30.06, "quantity": "square metres"}, "party_wall_length": {"value": 9.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 316, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 216, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 81}}], "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1742, "impact_of_cavity_insulation": -2178, "space_heating_existing_dwelling": 4294}, "energy_consumption_current": 313, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 209, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 11098381, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DN35 0PQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CLEETHORPES", "built_form": 2, "created_at": "2017-04-28 12:04:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16841}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Benjamins Walk", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.16, "quantity": "square metres"}, "party_wall_length": {"value": 9.01, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 19.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 41.16, "quantity": "square metres"}, "party_wall_length": {"value": 9.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 385, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 393, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1855, "space_heating_existing_dwelling": 5771}, "energy_consumption_current": 160, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["N", "U"], "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061889812, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 63% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN11 2QF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "WORTHING", "built_form": 4, "created_at": "2017-04-25 19:53:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "65, Ham Way", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.98, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 28.98, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 399, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 357, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2170, "impact_of_loft_insulation": -417, "space_heating_existing_dwelling": 5061}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 61, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100061564055, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU20 6PW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WINDLESHAM", "built_form": 2, "created_at": "2017-07-27 12:08:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50, Poplar Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-27", "inspection_date": "2017-07-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33.88, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 616, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 417, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 159, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1992, "impact_of_loft_insulation": -199, "impact_of_cavity_insulation": -3311, "space_heating_existing_dwelling": 10268}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 96, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100080365086, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SL6 3BG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 2, "created_at": "2017-08-25 19:41:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9968}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "9, St. Chads Road", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.68, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 270, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 226, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 120, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2430, "space_heating_existing_dwelling": 3340}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 183, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 50110697, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT18 7QZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FOLKESTONE", "built_form": 3, "created_at": "2017-04-25 18:29:32.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Pannell Drive", "address_line_2": "Hawkinge", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 325, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.34, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 27.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 42.34, "quantity": "square metres"}, "party_wall_length": {"value": 0.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.26, "quantity": "square metres"}, "party_wall_length": {"value": 4.48, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 454, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 458, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2345, "space_heating_existing_dwelling": 5888}, "energy_consumption_current": 146, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 70, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100061381010, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 65% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GU2 9GY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "GUILDFORD", "built_form": 2, "created_at": "2017-05-25 18:00:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Angelica Road", "assessment_type": "RdSAP", "completion_date": "2017-05-25", "inspection_date": "2017-05-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 37.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 65, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 450, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 350, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2547, "impact_of_loft_insulation": -459, "space_heating_existing_dwelling": 5604}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 64, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100030374593, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DE21 4JA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 2, "created_at": "2017-08-29 07:19:45.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17511}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "45, Wilson Road", "address_line_2": "Chaddesden", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.25, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 838, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 386, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 231, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 7, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1901, "impact_of_loft_insulation": -3310, "impact_of_solid_wall_insulation": -5121, "space_heating_existing_dwelling": 15988}, "energy_consumption_current": 313, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 71, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200003841344, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE7 8PP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "ILKESTON", "built_form": 3, "created_at": "2017-08-26 09:43:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "75, Beatty Walk", "assessment_type": "RdSAP", "completion_date": "2017-08-26", "inspection_date": "2017-08-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.12, "quantity": "square metres"}, "party_wall_length": {"value": 7.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 35.12, "quantity": "square metres"}, "party_wall_length": {"value": 7.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 787, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 390, "currency": "GBP"}, "hot_water_cost_current": {"value": 253, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 115, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 8, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 162, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 137, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3402, "impact_of_loft_insulation": -569, "impact_of_cavity_insulation": -2003, "space_heating_existing_dwelling": 9766}, "energy_consumption_current": 406, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 90, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050986885, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S6 5QT", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2017-04-26 15:13:11.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2309, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "12, Hall Park Head", "assessment_type": "RdSAP", "completion_date": "2017-04-26", "inspection_date": "2017-04-26", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 68, "transaction_type": 2, "conservatory_type": 2, "heated_room_count": 3, "registration_date": "2017-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.34, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.96, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 477, "currency": "GBP"}, "insulated_door_count": 1, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Charging system linked to use of community heating, programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 385, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "insulated_door_u_value": 1.7, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.2, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2080, "impact_of_cavity_insulation": -485, "space_heating_existing_dwelling": 5606}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 188, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 33034453, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TW17 9AU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEPPERTON", "built_form": 2, "created_at": "2017-06-28 20:31:09.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17761}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "68a, High Street", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 74.04, "quantity": "square metres"}, "party_wall_length": {"value": 16.15, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 27.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 685, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 417, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 87, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 202, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.3, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2087, "impact_of_loft_insulation": -1385, "impact_of_solid_wall_insulation": -4348, "space_heating_existing_dwelling": 12145}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 87, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 178, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100070273255, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "B6 7NR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-06-28 09:53:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "20, Alfred Street", "address_line_2": "Aston", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.59, "quantity": "square metres"}, "party_wall_length": {"value": 10.07, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 338, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 301, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1776, "space_heating_existing_dwelling": 4761}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 176, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100000007802, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NE39 2JY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROWLANDS GILL", "built_form": 2, "created_at": "2017-09-26 15:56:05.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "72, Whinfield Terrace", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.44, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.44, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 757, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 722, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2248, "impact_of_loft_insulation": -3902, "space_heating_existing_dwelling": 11331}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 190, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100011532675, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 18% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SK2 5UU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 2, "created_at": "2017-07-27 09:21:16.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17117}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "8, Whinchat Close", "assessment_type": "RdSAP", "completion_date": "2017-07-27", "inspection_date": "2017-07-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.74, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 37.74, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 577, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 474, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 85, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2060, "impact_of_loft_insulation": -555, "space_heating_existing_dwelling": 9067}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 91, "calculation_software_version": "2.11r11", "energy_consumption_potential": 103, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10034875951, "roofs": [{"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 13% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CT13 0DE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SANDWICH", "built_form": 1, "created_at": "2017-06-26 06:59:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Norken", "address_line_2": "Johns Green", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 181, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 89.97, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 91.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 42.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1309, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 168, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1254, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 61}], "co2_emissions_potential": 5.6, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3009, "impact_of_loft_insulation": -57, "space_heating_existing_dwelling": 22765}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 175, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100012383211, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BB10 3DS", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURNLEY", "built_form": 6, "created_at": "2017-07-04 14:23:54.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "51 Browhead Court", "address_line_2": "Shackleton Street", "assessment_type": "RdSAP", "completion_date": "2017-07-04", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 28, "transaction_type": 10, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.9, "quantity": "square metres"}, "party_wall_length": {"value": 14.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 175, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 175, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.5, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 187, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3171, "space_heating_existing_dwelling": 1398}, "energy_consumption_current": 313, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 313, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100040400116, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL19 0ER", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TAVISTOCK", "built_form": 1, "created_at": "2017-04-27 12:00:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 10338}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Redmoor Close", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.21, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.43, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 531, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 445, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2085, "space_heating_existing_dwelling": 8684}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N4 3LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-05-27 13:43:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "18a Birnam Road", "assessment_type": "RdSAP", "completion_date": "2017-05-27", "inspection_date": "2017-05-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 16.45, "quantity": "square metres"}, "party_wall_length": {"value": 11.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.06, "quantity": "metres"}, "total_floor_area": {"value": 47.73, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 635, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a35", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1922, "impact_of_solid_wall_insulation": -5282, "space_heating_existing_dwelling": 9152}, "energy_consumption_current": 316, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 120, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 2, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100050653607, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S71 1JU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BARNSLEY", "built_form": 2, "created_at": "2017-06-07 16:27:22.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "116, Rockingham Street", "assessment_type": "RdSAP", "completion_date": "2017-06-07", "inspection_date": "2017-05-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-06-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.12, "quantity": "square metres"}, "party_wall_length": {"value": 5.83, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.59, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 46.12, "quantity": "square metres"}, "party_wall_length": {"value": 5.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.65, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 825, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 575, "currency": "GBP"}, "hot_water_cost_current": {"value": 268, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 253, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 169, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 326, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3597, "impact_of_loft_insulation": -336, "space_heating_existing_dwelling": 10329}, "energy_consumption_current": 304, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100080027851, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK41 9HT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 4, "created_at": "2017-10-27 13:52:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17982}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "14a, Monkshill", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 6.5}, "total_floor_area": 59, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.43, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.96, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 329, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 279, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1869, "space_heating_existing_dwelling": 4726}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 151, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090639841, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CO11 1NF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MANNINGTREE", "built_form": 6, "created_at": "2017-05-04 11:27:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Enclosed Mid-Terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Remercie Road", "address_line_2": "Mistley", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-04-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 39, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.64, "quantity": "square metres"}, "party_wall_length": {"value": 9.43, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.53, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 19.64, "quantity": "square metres"}, "party_wall_length": {"value": 9.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 437, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 296, "currency": "GBP"}, "hot_water_cost_current": {"value": 165, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 134, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.4, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 93, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 99, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2383, "impact_of_loft_insulation": -209, "space_heating_existing_dwelling": 5168}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 53, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 3455031579, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ST3 7YR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2017-09-26 17:11:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16448}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Dovecote Place", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.21, "quantity": "square metres"}, "party_wall_length": {"value": 14.93, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.53, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 35.1, "quantity": "square metres"}, "party_wall_length": {"value": 7.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.84, "quantity": "square metres"}, "party_wall_length": {"value": 2.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 483, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 492, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2759, "impact_of_loft_insulation": -29, "space_heating_existing_dwelling": 7183}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 130, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200004291721, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Full secondary glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CB1 9XW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CAMBRIDGE", "built_form": 3, "created_at": "2017-06-26 15:57:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "24, Windermere Close", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 683, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 368, "currency": "GBP"}, "hot_water_cost_current": {"value": 201, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 185, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 8, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 92}, {"sequence": 3, "typical_saving": {"value": 109, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2681, "impact_of_cavity_insulation": -2664, "space_heating_existing_dwelling": 8081}, "energy_consumption_current": 366, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 76, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010195427, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CW9 7PT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHWICH", "built_form": 3, "created_at": "2017-04-26 23:52:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "11, School Lane", "address_line_2": "Lostock Gralam", "assessment_type": "RdSAP", "completion_date": "2017-04-26", "inspection_date": "2017-04-26", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 50.6, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 526, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 323, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 76}}], "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2099, "impact_of_cavity_insulation": -3152, "space_heating_existing_dwelling": 8798}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 161, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100010203953, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WA6 9PG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FRODSHAM", "built_form": 1, "created_at": "2017-09-26 19:31:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15443}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "84, Old Chester Road", "address_line_2": "Helsby", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 91.06, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 763, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 554, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2917, "impact_of_loft_insulation": -92, "impact_of_cavity_insulation": -3101, "space_heating_existing_dwelling": 14172}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100051289466, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD18 2HN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHIPLEY", "built_form": 2, "created_at": "2017-06-26 20:03:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17904}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Poplar Grove", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.92, "quantity": "square metres"}, "party_wall_length": {"value": 6.94, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 32.41, "quantity": "square metres"}, "party_wall_length": {"value": 6.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 865, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 608, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 59}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2005, "impact_of_loft_insulation": -3226, "impact_of_cavity_insulation": -3941, "space_heating_existing_dwelling": 15062}, "energy_consumption_current": 376, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 178, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100100410140, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SA6 5HA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWANSEA", "built_form": 2, "created_at": "2017-09-26 15:16:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17215}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Down Street", "address_line_2": "Clydach", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.26, "quantity": "square metres"}, "party_wall_length": {"value": 9.94, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 30.26, "quantity": "square metres"}, "party_wall_length": {"value": 9.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.49, "quantity": "square metres"}, "party_wall_length": {"value": 4.13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 689, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 203, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1924, "impact_of_loft_insulation": -875, "impact_of_cavity_insulation": -686, "impact_of_solid_wall_insulation": -4341, "space_heating_existing_dwelling": 11779}, "energy_consumption_current": 298, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 80, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10070621651, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RH15 8QR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURGESS HILL", "built_form": 3, "created_at": "2017-09-27 21:42:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15016}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "37, Colmer Court", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7, "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.7, "quantity": "square metres"}, "party_wall_length": {"value": 6.57, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 42.7, "quantity": "square metres"}, "party_wall_length": {"value": 6.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.55, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 463, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2843, "impact_of_solid_wall_insulation": -416, "space_heating_existing_dwelling": 7610}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 78, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100040223006, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "EX4 1EN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "EXETER", "built_form": 4, "created_at": "2017-06-29 13:08:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Manor Road", "assessment_type": "RdSAP", "completion_date": "2017-06-29", "inspection_date": "2017-06-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.5, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 29.5, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.45, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 9.45, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 0.85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 863, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 477, "currency": "GBP"}, "hot_water_cost_current": {"value": 219, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 150, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 216, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3186, "impact_of_loft_insulation": -768, "impact_of_solid_wall_insulation": -3985, "space_heating_existing_dwelling": 10359}, "energy_consumption_current": 368, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100020210208, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA7 5QU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BEXLEYHEATH", "built_form": 2, "created_at": "2017-06-28 20:49:55.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 650}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "41, King Harolds Way", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.07, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 49.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.01, "quantity": "square metres"}, "party_wall_length": {"value": 3.31, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 10.38, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1178, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 614, "currency": "GBP"}, "hot_water_cost_current": {"value": 400, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 349, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 8, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 256, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 215, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 454, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5333, "impact_of_loft_insulation": -490, "impact_of_solid_wall_insulation": -4702, "space_heating_existing_dwelling": 15204}, "energy_consumption_current": 343, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10033164462, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT5 3RP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WHITSTABLE", "built_form": 1, "created_at": "2017-07-27 11:52:55.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "117, Eversleigh Rise", "assessment_type": "RdSAP", "completion_date": "2017-07-27", "inspection_date": "2017-07-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 311, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 46.96, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 23.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 311, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 13.63, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 505, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 505, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2269, "space_heating_existing_dwelling": 8132}, "energy_consumption_current": 157, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IG3 8NN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-06-23 17:42:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17815}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Ground Floor Flat", "address_line_2": "60 St. Albans Road", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-23", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.7, "quantity": "metres"}}, "total_floor_area": 50, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.02, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.95, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1708, "impact_of_solid_wall_insulation": -1709, "space_heating_existing_dwelling": 6478}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 175, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100022767213, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 4% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "W2 2LP", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2017-06-26 11:37:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2301, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "true"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 20", "address_line_2": "19-20, Hyde Park Place", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-23", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.99, "quantity": "metres"}}, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 425, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 26.486, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 130, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 37.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.419, "quantity": "metres"}, "total_floor_area": {"value": 23.42, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.462, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 4, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 870, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, no thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 410, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 85, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3115", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.5, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 55}}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2005, "impact_of_cavity_insulation": -1231, "impact_of_solid_wall_insulation": -1525, "space_heating_existing_dwelling": 12552}, "energy_consumption_current": 476, "has_fixed_air_conditioning": "true", "multiple_glazed_proportion": 85, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 233, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100062496062, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in 95% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH5 5AQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DORKING", "built_form": 1, "created_at": "2017-09-18 14:23:23", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 3, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "secondary_heating_type": 607, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Becket Wood", "address_line_2": "Newdigate", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-08-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 222, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 10, "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 3, "peak_power": {"value": 3.36, "quantity": "kW"}, "orientation": 7, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, LPG", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 101.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 41.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 98.95, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 45.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 95, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 1354, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1198, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "co2_emissions_potential": 4.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 111, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3015, "impact_of_loft_insulation": -146, "space_heating_existing_dwelling": 19053}, "energy_consumption_current": 122, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100061907516, "roofs": [{"description": {"value": "Pitched, 25 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly multiple glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BN13 2NP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "WORTHING", "built_form": 1, "created_at": "2017-04-20 09:03:30.000000", "door_count": 0, "glazed_area": 4, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "false", "orientation": 4, "window_area": {"value": 2.77, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 3.24, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 6, "window_area": {"value": 2.78, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 8, "window_area": {"value": 1.49, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 8, "window_area": {"value": 1.12, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 1.28, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 2.77, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 8, "window_area": {"value": 0.21, "quantity": "square metres"}, "window_type": 1, "glazing_type": 4, "window_location": 0, "window_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 8, "window_area": {"value": 0.38, "quantity": "square metres"}, "window_type": 1, "glazing_type": 4, "window_location": 0, "window_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 8, "window_area": {"value": 1.53, "quantity": "square metres"}, "window_type": 1, "glazing_type": 4, "window_location": 0, "window_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 8, "window_area": {"value": 0.13, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0, "window_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}}, {"orientation": 8, "window_area": {"value": 0.33, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0, "window_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}}, {"orientation": 8, "window_area": {"value": 0.12, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0, "window_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "31, Twyford Road", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-03-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 77.91, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1287, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 32, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 460, "currency": "GBP"}, "hot_water_cost_current": {"value": 339, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 77, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 32}, {"sequence": 2, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 6, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 7, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 8, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 10, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 174, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 92}, {"sequence": 3, "typical_saving": {"value": 123, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 290, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3761, "impact_of_loft_insulation": -2583, "impact_of_cavity_insulation": -3364, "space_heating_existing_dwelling": 14583}, "energy_consumption_current": 597, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 27, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "F", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 63022453, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 85% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF9 3QT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTEFRACT", "built_form": 2, "created_at": "2017-06-23 17:07:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Church Mount", "address_line_2": "South Kirkby", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-23", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 345, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.55, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.74, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 46.55, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.91, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1246, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 752, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 5, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 8, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 3.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 234, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2176, "impact_of_loft_insulation": -845, "impact_of_cavity_insulation": -931, "space_heating_existing_dwelling": 17230}, "energy_consumption_current": 434, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 197, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10010031976, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SA4 3RG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWANSEA", "built_form": 1, "created_at": "2017-08-23 23:53:52.000000", "door_count": 0, "glazed_area": 2, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 914, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 6, "rooms_with_mixer_shower_no_bath": 4, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0.5, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9801}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 0.5, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 1709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1 Dove Lodge", "address_line_2": "Penclawdd", "assessment_type": "RdSAP", "completion_date": "2017-08-23", "inspection_date": "2017-08-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 368, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 12, "pvc_window_frames": "true", "registration_date": "2017-08-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 147.84, "insulation": 5, "roof_room_connected": "N", "construction_age_band": "I", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 220.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 70.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 12, "heating_cost_current": {"value": 1414, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 170, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1200, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 83}], "co2_emissions_potential": 4.1, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 170, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1833, "space_heating_existing_dwelling": 23694}, "energy_consumption_current": 123, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 62, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 77131761, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "M20 4NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 1, "created_at": "2017-08-25 17:41:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "92, Mauldeth Road", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.1, "quantity": "square metres"}, "party_wall_length": {"value": 5.75, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 43.1, "quantity": "square metres"}, "party_wall_length": {"value": 11.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.58, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1249, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 647, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 63, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 36}, {"sequence": 2, "typical_saving": {"value": 339, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 8, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 9, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 52}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "impact_of_loft_insulation": -367, "impact_of_cavity_insulation": -5902, "space_heating_existing_dwelling": 19815}, "energy_consumption_current": 417, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 156, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100120443154, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GL19 3RX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "GLOUCESTER", "built_form": 1, "created_at": "2017-05-25 16:27:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8435}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Cullingham Close", "address_line_2": "Staunton", "assessment_type": "RdSAP", "completion_date": "2017-05-25", "inspection_date": "2017-05-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 133, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-05-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 64.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 34.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 805, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 608, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.8, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 96, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2964, "impact_of_loft_insulation": -1039, "space_heating_existing_dwelling": 13503}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 103, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100060896229, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT14 9LS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "DEAL", "built_form": 2, "created_at": "2017-06-23 17:30:11.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, St. Francis Close", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 289, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.22, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 39.22, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 353, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.08, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.64, "quantity": "square metres"}, "party_wall_length": {"value": 3.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 448, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2408, "impact_of_loft_insulation": -813, "space_heating_existing_dwelling": 8707}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 84, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 63020316, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF1 2LJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WAKEFIELD", "built_form": 2, "created_at": "2017-10-24 08:58:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Charles Avenue", "address_line_2": "Outwood", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 766, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 716, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2190, "impact_of_loft_insulation": -4121, "space_heating_existing_dwelling": 13486}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 183, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100091051554, "roofs": [{"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 8% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "IP2 9TE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IPSWICH", "built_form": 3, "created_at": "2017-06-26 08:56:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17073}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "1, Fritton Close", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 35.98, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.99, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "100mm"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 527, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 493, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2026, "space_heating_existing_dwelling": 7141}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 104, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100021537134, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TW14 8PR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FELTHAM", "built_form": 2, "created_at": "2017-10-23 15:54:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9714}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, West View", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.15, "quantity": "square metres"}, "party_wall_length": {"value": 7.75, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.99, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 43.15, "quantity": "square metres"}, "party_wall_length": {"value": 7.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 586, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2185, "impact_of_loft_insulation": -222, "impact_of_cavity_insulation": -3343, "space_heating_existing_dwelling": 10297}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 74, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 2465135227, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE5 1HL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 4, "created_at": "2017-06-26 18:14:24.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15274}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Grantham Road", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.68, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 31.68, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.4, "quantity": "square metres"}, "party_wall_length": {"value": 3.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 633, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1998, "impact_of_loft_insulation": -826, "impact_of_cavity_insulation": -762, "impact_of_solid_wall_insulation": -414, "space_heating_existing_dwelling": 9923}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200001393769, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NG7 6PU", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2017-07-24 12:15:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 0.5, "sap_main_heating_code": 603, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 26, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 0.5, "sap_main_heating_code": 609, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Stanley Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-23", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.73, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 11.73, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.86, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 9.86, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.07, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 517, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 268, "currency": "GBP"}, "hot_water_cost_current": {"value": 319, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 7, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3120", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 8, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 9, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 10, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.4, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 139, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 194, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2030, "impact_of_cavity_insulation": -348, "impact_of_solid_wall_insulation": -1032, "space_heating_existing_dwelling": 5569}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "1.0.x", "energy_consumption_potential": 47, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 27, "current_energy_efficiency_band": "E", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 45106743, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE37 2HT", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "WASHINGTON", "built_form": 4, "created_at": "2017-06-01 08:44:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "10, Roseberry Court", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-02-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 6.0}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.0, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 272, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 240, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 98}], "co2_emissions_potential": 1.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1404, "impact_of_solid_wall_insulation": -303, "space_heating_existing_dwelling": 3041}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 186, "environmental_impact_current": 98, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 98, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070624776, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV5 7AB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 1, "created_at": "2017-07-01 11:04:06.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16843}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Broad Lane", "assessment_type": "RdSAP", "completion_date": "2017-07-01", "inspection_date": "2017-06-28", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 226, "transaction_type": 11, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 110.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 47.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 121.72, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 38.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1142, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1048, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 75}], "co2_emissions_potential": 4.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 102, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 101, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2136, "space_heating_existing_dwelling": 22038}, "energy_consumption_current": 156, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 120, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100060922731, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA13 9JJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}, "post_town": "GRAVESEND", "built_form": 1, "created_at": "2017-07-28 10:34:47.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Brookside Road", "address_line_2": "Istead Rise", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 123, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 20.64, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 908, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 679, "currency": "GBP"}, "hot_water_cost_current": {"value": 176, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 206, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 250, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2822, "impact_of_loft_insulation": -1625, "space_heating_existing_dwelling": 13545}, "energy_consumption_current": 256, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 123, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100062137790, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RH4 2EN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "DORKING", "built_form": 2, "created_at": "2017-07-28 18:43:43.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "35, Bartholemew Court", "address_line_2": "South Street", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.31, "quantity": "square metres"}, "party_wall_length": {"value": 8.17, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 23.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 434, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 328, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 56}], "co2_emissions_potential": 3.1, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1730, "space_heating_existing_dwelling": 5222}, "energy_consumption_current": 436, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 353, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060044804, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TN38 0PG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. LEONARDS-ON-SEA", "built_form": 1, "created_at": "2017-04-28 17:49:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8580}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "78, Filsham Road", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 227, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 87.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 88.33, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 16.91, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.34, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 204, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1265, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": 85, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 134, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "co2_emissions_potential": 5.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 102, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 410, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 133, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3014, "impact_of_loft_insulation": -4033, "space_heating_existing_dwelling": 21610}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 135, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100070298646, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B10 0AU", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2017-10-02 09:41:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "282, Bolton Road", "assessment_type": "RdSAP", "completion_date": "2017-10-02", "inspection_date": "2017-09-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.13, "quantity": "metres"}}, "total_floor_area": 46, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.112, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 5, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.45, "quantity": "square metres"}, "party_wall_length": {"value": 15.85, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 428, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 197, "currency": "GBP"}, "hot_water_cost_current": {"value": 222, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 240, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 209, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1639, "space_heating_existing_dwelling": 4806}, "energy_consumption_current": 441, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 285, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100050536546, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO23 1NY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "YORK", "built_form": 2, "created_at": "2017-04-29 08:07:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "113, Bishopthorpe Road", "assessment_type": "RdSAP", "completion_date": "2017-04-29", "inspection_date": "2017-04-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 287, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.65, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 41.65, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.63, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 288, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.42, "quantity": "square metres"}, "party_wall_length": {"value": 0.97, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.53, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 746, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 604, "currency": "GBP"}, "hot_water_cost_current": {"value": 233, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 237, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3548, "impact_of_loft_insulation": -515, "space_heating_existing_dwelling": 9652}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "9.0.0", "energy_consumption_potential": 144, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100120562448, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 45% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "B45 9UP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-09-28 15:08:56.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "51, Lyndon Road", "address_line_2": "Rubery, Rednal", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.7, "quantity": "square metres"}, "party_wall_length": {"value": 6.37, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 30.63, "quantity": "square metres"}, "party_wall_length": {"value": 6.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.85, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 881, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 672, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2328, "impact_of_loft_insulation": -2686, "impact_of_solid_wall_insulation": -3175, "space_heating_existing_dwelling": 15765}, "energy_consumption_current": 310, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 166, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100011359990, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [10]}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M30 7AR", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 3, "created_at": "2017-05-04 09:09:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "23, Ermen Road", "address_line_2": "Eccles", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-04-28", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.6, "quantity": "square metres"}, "party_wall_length": {"value": 11, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 1508, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 16, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 364, "currency": "GBP"}, "hot_water_cost_current": {"value": 160, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 616, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 44}, {"sequence": 3, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 452, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.9, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 433, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 376, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 403, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1015, "impact_of_loft_insulation": -1284, "impact_of_solid_wall_insulation": -4628, "space_heating_existing_dwelling": 11076}, "energy_consumption_current": 809, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["T2"], "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 233, "environmental_impact_current": 22, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "G", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 137, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 24114077, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 41% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BS20 8NB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2017-07-28 15:38:50.000000", "door_count": 7, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8874}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "41, Charlcombe Rise", "address_line_2": "Portishead", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 280, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 9, "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 65.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 65.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 32.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.32, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 41, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1222, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 186, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1234, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 80, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 72}], "co2_emissions_potential": 6.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 117, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2820, "space_heating_existing_dwelling": 21544}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 122, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 27, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100050930316, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S35 1SL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2017-07-28 13:54:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "402, Burncross Road", "address_line_2": "Burncross", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 480, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.9, "quantity": "square metres"}, "party_wall_length": 2.6, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 3.9, "quantity": "square metres"}, "party_wall_length": 2.6, "heat_loss_perimeter": {"value": 0.1, "quantity": "metres"}}, {"floor": 2, "room_height": 2.4, "total_floor_area": 3.9, "party_wall_length": 2.6, "heat_loss_perimeter": 4}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.9, "quantity": "square metres"}, "party_wall_length": 2.6, "floor_construction": 1, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 3.9, "quantity": "square metres"}, "party_wall_length": 2.6, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 803, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 734, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2218, "impact_of_loft_insulation": -3620, "impact_of_solid_wall_insulation": -919, "space_heating_existing_dwelling": 14716}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 150, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090668486, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SS9 2JE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEIGH-ON-SEA", "built_form": 1, "created_at": "2017-09-28 23:27:56", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Marine Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 166, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 67.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 40.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1629, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 774, "currency": "GBP"}, "hot_water_cost_current": {"value": 174, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 674, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 243, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2986, "impact_of_solid_wall_insulation": -11719, "space_heating_existing_dwelling": 26396}, "energy_consumption_current": 308, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 106, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100070258718, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV34 5HZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WARWICK", "built_form": 4, "created_at": "2017-09-28 15:51:53.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "22, Arundel Close", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-28", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38, "quantity": "square metres"}, "party_wall_length": {"value": 13.48, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 38.79, "quantity": "square metres"}, "party_wall_length": {"value": 13.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.42, "quantity": "square metres"}, "party_wall_length": {"value": 2.12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 496, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 391, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2021, "impact_of_cavity_insulation": -1786, "space_heating_existing_dwelling": 8226}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 83, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10002169810, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IG11 7BB", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARKING", "built_form": 4, "created_at": "2017-10-28 23:48:06.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2304, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 7 Benedicts Wharf", "address_line_2": "Highbridge Road", "assessment_type": "RdSAP", "completion_date": "2017-10-28", "inspection_date": "2017-10-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.51, "quantity": "metres"}}, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.6436, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.07, "quantity": "square metres"}, "party_wall_length": {"value": 20.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 207, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 210, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2062, "space_heating_existing_dwelling": 2040}, "energy_consumption_current": 132, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 128, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100070128719, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B78 1TG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TAMWORTH", "built_form": 4, "created_at": "2017-06-21 14:54:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8361}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "39, New Street", "address_line_2": "Dordon", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.66, "quantity": "square metres"}, "party_wall_length": {"value": 8.65, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 39.02, "quantity": "square metres"}, "party_wall_length": {"value": 19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.41, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1361, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 37, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 719, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 5, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 6, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 7, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 8, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 9, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 55}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2111, "impact_of_loft_insulation": -4028, "impact_of_solid_wall_insulation": -5859, "space_heating_existing_dwelling": 21284}, "energy_consumption_current": 504, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 14, "calculation_software_version": "2.11r11", "energy_consumption_potential": 191, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "F", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 91, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100091044967, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP3 0SD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IPSWICH", "built_form": 2, "created_at": "2017-09-21 16:38:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8358}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "40, Coleness Road", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.86, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 31.86, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.51, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.27, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 16.27, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 820, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 675, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 199, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2276, "impact_of_loft_insulation": -1575, "space_heating_existing_dwelling": 11341}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 117, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 11065964, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DN36 4XJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 1, "created_at": "2017-09-21 12:26:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17246}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Lidgard Road", "address_line_2": "Humberston", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33.48, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 33.48, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 765, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 703, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2233, "space_heating_existing_dwelling": 11267}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 140, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100120680547, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WR9 9HH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DROITWICH", "built_form": 4, "created_at": "2017-06-22 15:07:06.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "28, Charland Court", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 2}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.8, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 310, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.18, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 250, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 225, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1638, "space_heating_existing_dwelling": 2890}, "energy_consumption_current": 153, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 138, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070545358, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B11 3QR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2017-04-23 14:21:07.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "76, Tynedale Road", "assessment_type": "RdSAP", "completion_date": "2017-04-23", "inspection_date": "2017-04-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.83, "quantity": "square metres"}, "party_wall_length": {"value": 12.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 30.83, "quantity": "square metres"}, "party_wall_length": {"value": 12.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 816, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 8, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2056, "impact_of_loft_insulation": -338, "impact_of_solid_wall_insulation": -1660, "space_heating_existing_dwelling": 11422}, "energy_consumption_current": 351, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 422000047530, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OL2 5LS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OLDHAM", "built_form": 2, "created_at": "2017-07-22 16:52:38.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "164, Middleton Road", "address_line_2": "Royton", "assessment_type": "RdSAP", "completion_date": "2017-07-22", "inspection_date": "2017-07-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 509, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1808, "space_heating_existing_dwelling": 8315}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 128, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 452059440, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TF1 3HH", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "TELFORD", "built_form": 2, "created_at": "2017-07-21 17:31:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.2, "sap_main_heating_code": 610, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 26, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.8, "sap_main_heating_code": 609, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Colemere Drive", "address_line_2": "Wellington", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-07-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 37.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 602, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 419, "currency": "GBP"}, "hot_water_cost_current": {"value": 436, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 365, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 135, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 208, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2780, "space_heating_existing_dwelling": 7546}, "energy_consumption_current": 335, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 95, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100020429018, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 5% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BR2 6HW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "KESTON", "built_form": 1, "created_at": "2017-07-30 07:18:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, The Dale", "assessment_type": "RdSAP", "completion_date": "2017-07-30", "inspection_date": "2017-07-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 141, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 61.6, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 32.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 5, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1559, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.1, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 154, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 897, "currency": "GBP"}, "hot_water_cost_current": {"value": 174, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 250, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.9, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 89}, {"sequence": 3, "typical_saving": {"value": 342, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2768, "impact_of_loft_insulation": -4662, "impact_of_cavity_insulation": -6303, "space_heating_existing_dwelling": 24071}, "energy_consumption_current": 367, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "9.0.0", "energy_consumption_potential": 155, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100061908739, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN13 3PF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORTHING", "built_form": 3, "created_at": "2017-09-21 09:45:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "37, Wear Road", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.05, "quantity": "square metres"}, "party_wall_length": {"value": 6.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 38.05, "quantity": "square metres"}, "party_wall_length": {"value": 6.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.58, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.77, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.2, "quantity": "square metres"}, "party_wall_length": {"value": 1.13, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.83, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 577, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 549, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2828, "impact_of_loft_insulation": -2553, "space_heating_existing_dwelling": 10110}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 130, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100040504691, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL1 5LU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 4, "created_at": "2017-06-21 13:23:32", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Wilton Street", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-21", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 20}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 588, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.02, "quantity": "square metres"}, "party_wall_length": {"value": 8.94, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 21.72, "quantity": "square metres"}, "party_wall_length": {"value": 8.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 543, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.58, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 14.58, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.16, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 14.58, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.11, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.32, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 11.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 989, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 606, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2119, "impact_of_solid_wall_insulation": -5635, "space_heating_existing_dwelling": 16707}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 123, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100080487344, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL0 9QN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IVER", "built_form": 2, "created_at": "2017-06-21 20:28:48", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Langley Park Road", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.58, "quantity": "square metres"}, "party_wall_length": {"value": 9.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.56, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 35.92, "quantity": "square metres"}, "party_wall_length": {"value": 10.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 739, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 383, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2608, "impact_of_loft_insulation": -188, "impact_of_solid_wall_insulation": -5159, "space_heating_existing_dwelling": 12560}, "energy_consumption_current": 313, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.11r11", "energy_consumption_potential": 76, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 45113129, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DH5 0NP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-05-31 19:24:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "9, Coronation Green", "address_line_2": "Easington Lane", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-05-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 364, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1626, "impact_of_loft_insulation": -737, "space_heating_existing_dwelling": 7124}, "energy_consumption_current": 328, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031771511, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "ST16 1JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 1, "created_at": "2017-08-21 12:21:52.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15032}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "9, Lapley Avenue", "assessment_type": "RdSAP", "completion_date": "2017-08-21", "inspection_date": "2017-08-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 5.25, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 4.6, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 68.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 554, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 480, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2757, "space_heating_existing_dwelling": 9288}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 124, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050702685, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN7 4AL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DONCASTER", "built_form": 2, "created_at": "2017-04-22 16:02:23.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16093}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "92, Broadway", "address_line_2": "Dunscroft", "assessment_type": "RdSAP", "completion_date": "2017-04-22", "inspection_date": "2017-04-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.49, "quantity": "square metres"}, "party_wall_length": {"value": 4.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 42.49, "quantity": "square metres"}, "party_wall_length": {"value": 4.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.15, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "200mm"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 486, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 439, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2470, "impact_of_loft_insulation": -468, "space_heating_existing_dwelling": 7924}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 45125417, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DH5 9AP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 3, "created_at": "2017-05-31 22:25:35", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "23, Jane Street", "address_line_2": "Hetton-le-Hole", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-05-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 30}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.7, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.7, "quantity": "square metres"}, "party_wall_length": {"value": 0.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 779, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 588, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 98}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 169, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 40, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1675, "space_heating_existing_dwelling": 9718}, "energy_consumption_current": 357, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 214, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061859234, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN6 8PJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HASSOCKS", "built_form": 2, "created_at": "2017-09-21 19:02:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Farm Close", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.86, "quantity": "square metres"}, "party_wall_length": {"value": 7.37, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 619, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 390, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1755, "impact_of_loft_insulation": -606, "impact_of_cavity_insulation": -3075, "space_heating_existing_dwelling": 11096}, "energy_consumption_current": 289, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 84, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100061803900, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RH13 5BL", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HORSHAM", "built_form": 2, "created_at": "2017-07-21 19:27:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 631, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "7a, Bedford Road", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-07-21", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0, "unheated_corridor_length": {"value": 0, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": {"value": 21.46, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 38.76, "quantity": "square metres"}, "party_wall_length": {"value": 11.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 0.7, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.13, "quantity": "square metres"}, "party_wall_length": {"value": 7.93, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 2249, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 14, "energy_rating_average": 60, "energy_rating_current": 1, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 862, "currency": "GBP"}, "hot_water_cost_current": {"value": 562, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 57, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 959, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 16, "environmental_impact_rating": 13}, {"sequence": 2, "typical_saving": {"value": 217, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 22, "environmental_impact_rating": 18}, {"sequence": 3, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 25}, {"sequence": 4, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 31}, {"sequence": 5, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 32}, {"sequence": 6, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 32}, {"sequence": 7, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 35}, {"sequence": 8, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 36}], "co2_emissions_potential": 5.3, "energy_rating_potential": 42, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 33, "environmental_impact_rating": 26}}], "hot_water_cost_potential": {"value": 204, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5919, "impact_of_loft_insulation": -1859, "impact_of_cavity_insulation": -1475, "impact_of_solid_wall_insulation": -1929, "space_heating_existing_dwelling": 15451}, "energy_consumption_current": 1083, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "9.0.0", "energy_consumption_potential": 414, "environmental_impact_current": 1, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "G", "environmental_impact_potential": 36, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 220, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100021805035, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 98% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW16 5AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-08-21 15:19:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, Aberfoyle Road", "assessment_type": "RdSAP", "completion_date": "2017-08-21", "inspection_date": "2017-08-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 25, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.9, "quantity": "square metres"}, "party_wall_length": {"value": 1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 98, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 592, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 533, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1994, "impact_of_loft_insulation": -1636, "impact_of_cavity_insulation": -1369, "space_heating_existing_dwelling": 10485}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 49, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 48} +{"uprn": 45111575, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE37 2JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 2, "created_at": "2017-06-01 02:57:08.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Glendale Avenue", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-02-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 526, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2186, "space_heating_existing_dwelling": 9630}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 104, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 766292470, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HP21 8NS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AYLESBURY", "built_form": 2, "created_at": "2017-06-26 15:34:29.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "14, Hampden Close", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-03-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 3.23, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 583, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 312, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2162, "impact_of_loft_insulation": -3595, "space_heating_existing_dwelling": 7724}, "energy_consumption_current": 435, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 74, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100040212285, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 81% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX3 0LX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EXETER", "built_form": 3, "created_at": "2017-09-21 13:38:16", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9717}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "51, Exeter Road", "address_line_2": "Topsham", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.2, "quantity": "square metres"}, "party_wall_length": {"value": 4.86, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 43.25, "quantity": "square metres"}, "party_wall_length": {"value": 4.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.37, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 14.37, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.67, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 81, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 678, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 573, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2977, "impact_of_loft_insulation": -611, "impact_of_cavity_insulation": -2326, "space_heating_existing_dwelling": 11539}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 90, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100091523653, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PE2 5PW", "hot_water": {"description": "Community scheme, no cylinder thermostat", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 4, "created_at": "2017-05-04 19:13:40.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "62, Herlington", "address_line_2": "Orton Malborne", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-03-21", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 0.86}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 27.34, "quantity": "square metres"}, "party_wall_length": {"value": 9.37, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 2.064, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 310, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 5.15, "quantity": "square metres"}, "party_wall_length": {"value": 2.03, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 5.15, "quantity": "square metres"}, "party_wall_length": {"value": 2.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 261, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 275, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.7, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2639, "space_heating_existing_dwelling": 2855}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r10", "energy_consumption_potential": 256, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200001323907, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ST15 8SU", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "STONE", "built_form": 2, "created_at": "2017-04-21 16:53:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "41, Melrose Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-21", "inspection_date": "2017-04-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-04-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.91, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 26.91, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 676, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "\u00a31,600 - \u00a32,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 56}, {"sequence": 6, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 271, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 215, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1852, "impact_of_loft_insulation": -245, "space_heating_existing_dwelling": 7695}, "energy_consumption_current": 568, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 263, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 96, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 45108500, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE37 3BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 3, "created_at": "2017-05-31 21:13:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "34, Marlborough Road", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 9.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 9.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 755, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 437, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 8, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2173, "space_heating_existing_dwelling": 10945}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 85, "calculation_software_version": "1.0.x", "energy_consumption_potential": 88, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45100830, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SR2 8QW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 4, "created_at": "2017-06-01 19:38:53.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "181, Cairo Street", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 47.6, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 713, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 570, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2181, "space_heating_existing_dwelling": 10341}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 116, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU12 0AG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 2, "created_at": "2017-04-23 21:17:53.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17503}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Beck Cottage", "address_line_2": "Main Street", "address_line_3": "Ottringham", "assessment_type": "RdSAP", "completion_date": "2017-04-23", "inspection_date": "2017-04-20", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 174, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 360, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 24.78, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.78, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.4, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 59, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 25.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1569, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1101, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 30, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "co2_emissions_potential": 5.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 105, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2102, "impact_of_solid_wall_insulation": -6505, "space_heating_existing_dwelling": 30599}, "energy_consumption_current": 273, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 162, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10022839210, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "GL7 6AD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CIRENCESTER", "built_form": 1, "created_at": "2017-07-20 23:05:17.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 3, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1778}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Barradale", "address_line_2": "Kemble", "assessment_type": "RdSAP", "completion_date": "2017-07-20", "inspection_date": "2017-07-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 146, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, LPG", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 132.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.69, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.03, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.87, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 920, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 161, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 729, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a3150", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 84}], "co2_emissions_potential": 2.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2974, "space_heating_existing_dwelling": 14359}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 19, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 30, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 11063014, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN34 4AH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 2, "created_at": "2017-08-21 18:13:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8077}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Marshall Avenue", "assessment_type": "RdSAP", "completion_date": "2017-08-21", "inspection_date": "2017-08-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 16, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 907, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 637, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 159, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 152, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2265, "impact_of_cavity_insulation": -2802, "space_heating_existing_dwelling": 13887}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100021970026, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SE23 3SA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-07-20 21:57:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 9 Havelock House", "address_line_2": "Honor Oak Road", "assessment_type": "RdSAP", "completion_date": "2017-07-20", "inspection_date": "2017-07-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6, "quantity": "metres"}}, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 80, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 34.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 455, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 225, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 232, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1834, "impact_of_solid_wall_insulation": -5114, "space_heating_existing_dwelling": 7476}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100031256451, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NG17 2DF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUTTON-IN-ASHFIELD", "built_form": 3, "created_at": "2017-09-21 15:44:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Ridge Close", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 489, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1965, "space_heating_existing_dwelling": 7957}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100011463857, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SK5 6NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 4, "created_at": "2017-07-20 10:08:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Buckley Street", "assessment_type": "RdSAP", "completion_date": "2017-07-20", "inspection_date": "2017-07-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-07-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.84, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.47, "quantity": "square metres"}, "party_wall_length": {"value": 19.27, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.68, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 42.47, "quantity": "square metres"}, "party_wall_length": {"value": 19.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 756, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 533, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2395, "impact_of_solid_wall_insulation": -3489, "space_heating_existing_dwelling": 11128}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 117, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200002855085, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully triple glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 81% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PR6 9EG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHORLEY", "built_form": 1, "created_at": "2017-09-20 16:46:41.000000", "door_count": 3, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15049}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Hallsworth Manor", "address_line_2": "Long Lane", "address_line_3": "Heath Charnock", "assessment_type": "RdSAP", "completion_date": "2017-09-20", "inspection_date": "2017-09-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 327, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 21.84, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 134.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 39.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 134.13, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 39.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 480, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 18.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 81, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 2309, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 13, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 155, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 6, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1324, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 617, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 82}], "co2_emissions_potential": 4.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 155, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2865, "impact_of_loft_insulation": -106, "impact_of_solid_wall_insulation": -11851, "space_heating_existing_dwelling": 45059}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 80, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 32, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 26} +{"uprn": 100120902815, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX14 3AE", "hot_water": {"description": {"value": "Gas boiler/circulator", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ABINGDON", "built_form": 1, "created_at": "2017-08-03 13:28:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 911, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8206}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "79, Foxborough Road", "address_line_2": "Radley", "assessment_type": "RdSAP", "completion_date": "2017-08-03", "inspection_date": "2017-07-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "registration_date": "2017-08-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.38, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.45, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.49, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 573, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 398, "currency": "GBP"}, "hot_water_cost_current": {"value": 172, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2726, "impact_of_loft_insulation": -486, "space_heating_existing_dwelling": 8661}, "energy_consumption_current": 287, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10003810941, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [9]}, "lighting": {"description": {"value": "Low energy lighting in 52% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CO10 9SA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUDBURY", "built_form": 1, "created_at": "2017-06-21 15:43:54", "door_count": 2, "glazed_area": 2, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 914, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": 4, "main_heating_number": 1, "main_heating_control": 2207, "main_heating_category": 4, "main_heating_fraction": 0.5, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 102513}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15022}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, underfloor, electric", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Dean House", "address_line_2": "Church Street", "address_line_3": "Lavenham", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-20", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 213, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 113.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 41.315, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.231, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.89, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.713, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.22, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 52, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 893, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 143, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 900, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 3.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 96, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 126, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2549, "space_heating_existing_dwelling": 18199}, "energy_consumption_current": 123, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 31, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "W6 9NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-10-20 12:43:25.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "208b Fulham Palace Road", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.5, "quantity": "metres"}}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.8, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 41.88, "quantity": "square metres"}, "party_wall_length": {"value": 11.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 405, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 187, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 161, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 95, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2411, "impact_of_solid_wall_insulation": -2966, "space_heating_existing_dwelling": 5365}, "energy_consumption_current": 351, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 148, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45118157, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR5 5QJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-01 17:32:08.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Redhill Road", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.3, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 778, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 484, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 202, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "impact_of_loft_insulation": -3727, "space_heating_existing_dwelling": 12188}, "energy_consumption_current": 301, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 110, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 45114618, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SR5 4JY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-01 20:52:00", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Bailey Square", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 30.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 445, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 386, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1871, "impact_of_loft_insulation": -332, "space_heating_existing_dwelling": 6929}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 114, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 45099459, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SR4 9BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 03:47:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Dellfield Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 567, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2137, "space_heating_existing_dwelling": 7862}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "1.0.x", "energy_consumption_potential": 136, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100020267204, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DA16 2DY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLING", "built_form": 2, "created_at": "2017-08-20 16:55:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "37, Clinton Avenue", "assessment_type": "RdSAP", "completion_date": "2017-08-20", "inspection_date": "2017-08-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 2, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-08-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 15.76, "quantity": "square metres"}, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": {"value": 12.22, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 190, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 12.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 33.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 823, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 639, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2131, "impact_of_loft_insulation": -221, "impact_of_solid_wall_insulation": -3060, "space_heating_existing_dwelling": 13736}, "energy_consumption_current": 312, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 164, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 394009597, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "B78 3JJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TAMWORTH", "built_form": 4, "created_at": "2017-10-20 19:54:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15649}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18 Corrie Roy Cottages", "address_line_2": "Fazeley Road", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 59.15, "quantity": "square metres"}, "party_wall_length": {"value": 17.69, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 59.15, "quantity": "square metres"}, "party_wall_length": {"value": 17.69, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.81, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "100mm"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 495, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2287, "impact_of_loft_insulation": -433, "space_heating_existing_dwelling": 7425}, "energy_consumption_current": 144, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 84, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 2465064224, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LE4 2HB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-10-20 23:55:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "59, Helena Crescent", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.57, "quantity": "square metres"}, "party_wall_length": {"value": 6.39, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 28.57, "quantity": "square metres"}, "party_wall_length": {"value": 6.39, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.33, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 425, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 393, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2032, "space_heating_existing_dwelling": 6043}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 107, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 83019383, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HD3 4PP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 4, "created_at": "2017-07-04 11:03:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "5, Woodside Cottages", "address_line_2": "Milnsbridge", "assessment_type": "RdSAP", "completion_date": "2017-07-04", "inspection_date": "2017-06-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 24.03, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.81, "quantity": "metres"}, "total_floor_area": {"value": 24.03, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 262, "currency": "GBP"}, "hot_water_cost_current": {"value": 71, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 83, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 160, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1506, "impact_of_solid_wall_insulation": -3287, "space_heating_existing_dwelling": 6216}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 156, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10003765059, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TA24 8LB", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MINEHEAD", "built_form": 4, "created_at": "2017-10-03 07:59:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.6, "sap_main_heating_code": 408, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 0.4, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}, {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Rawles Buildings", "address_line_2": "Porlock", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-09-29", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 460, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.8, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.18, "quantity": "metres"}, "total_floor_area": {"value": 28.8, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.3, "quantity": "square metres"}, "party_wall_length": 1.5, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.2, "quantity": "square metres"}, "party_wall_length": 1.5, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 989, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 496, "currency": "GBP"}, "hot_water_cost_current": {"value": 272, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 16, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 53}, {"sequence": 7, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 9, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 133, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1985, "impact_of_loft_insulation": -169, "impact_of_solid_wall_insulation": -1905, "space_heating_existing_dwelling": 7559}, "energy_consumption_current": 475, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 146, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100070217378, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CV36 5EE", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "SHIPSTON-ON-STOUR", "built_form": 2, "created_at": "2017-06-20 17:50:28.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 33, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 633, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, coal", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Church Lane", "address_line_2": "Whatcote", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-03-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 46, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1147, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 13, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 610, "currency": "GBP"}, "hot_water_cost_current": {"value": 254, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 573, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 34}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 34}, {"sequence": 4, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 37}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 42}, {"sequence": 6, "typical_saving": {"value": 597, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 100, "environmental_impact_rating": 58}], "co2_emissions_potential": 3.7, "energy_rating_potential": 100, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2855, "impact_of_solid_wall_insulation": -8302, "space_heating_existing_dwelling": 16506}, "energy_consumption_current": 445, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 27, "environmental_impact_current": 10, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 58, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 147, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100090240986, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SS15 4AX", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BASILDON", "built_form": 1, "created_at": "2017-07-29 11:28:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.75, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1538}, {"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.25, "sap_main_heating_code": 604, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "60, Crouch Street", "assessment_type": "RdSAP", "completion_date": "2017-07-29", "inspection_date": "2017-07-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-07-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 51.4, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 819, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 604, "currency": "GBP"}, "hot_water_cost_current": {"value": 333, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 89, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 87}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 232, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4508, "space_heating_existing_dwelling": 10660}, "energy_consumption_current": 309, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100030226213, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S18 2LX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DRONFIELD", "built_form": 2, "created_at": "2017-09-19 22:02:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15520}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "41, Princess Road", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-08-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 111, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.57, "quantity": "square metres"}, "party_wall_length": {"value": 7.51, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 36.57, "quantity": "square metres"}, "party_wall_length": {"value": 7.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.75, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 20.57, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 12.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 694, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 694, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2272, "impact_of_loft_insulation": -249, "space_heating_existing_dwelling": 9999}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 130, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 10010621675, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE23 6TB", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 4, "created_at": "2017-07-29 15:38:46.000000", "door_count": 0, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6 Thornly House", "address_line_2": "35, Mount Carmel Street", "assessment_type": "RdSAP", "completion_date": "2017-07-29", "inspection_date": "2017-07-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 21, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-07-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 20.55, "quantity": "square metres"}, "party_wall_length": {"value": 13.49, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 6.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 270, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 164, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 19, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1625, "impact_of_solid_wall_insulation": -954, "space_heating_existing_dwelling": 3012}, "energy_consumption_current": 423, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 267, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 2, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100021346724, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM13 7AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RAINHAM", "built_form": 1, "created_at": "2017-09-04 20:40:44.000000", "door_count": 3, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1821}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "27, Alexandra Road", "assessment_type": "RdSAP", "completion_date": "2017-09-04", "inspection_date": "2017-08-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 33.12, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "J", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 11.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 788, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 503, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2260, "impact_of_solid_wall_insulation": -2608, "space_heating_existing_dwelling": 12117}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100064117, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM6 6ED", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROMFORD", "built_form": 4, "created_at": "2017-08-29 16:59:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8440}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Morden Road", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 29.19, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.715, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.866, "quantity": "square metres"}, "party_wall_length": {"value": 14.872, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.865, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.578, "quantity": "metres"}, "total_floor_area": {"value": 41.456, "quantity": "square metres"}, "party_wall_length": {"value": 14.872, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.15, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.349, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.518, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.317, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 843, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 569, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2286, "impact_of_loft_insulation": -1378, "impact_of_solid_wall_insulation": -1656, "space_heating_existing_dwelling": 13060}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 100, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100100088218, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CF5 3LT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 1, "created_at": "2017-09-29 16:01:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Flat 4 Laurel Court", "address_line_2": "Plasmawr Road", "assessment_type": "RdSAP", "completion_date": "2017-09-29", "inspection_date": "2017-09-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 111, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.42, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 48.42, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1130, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 136, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 602, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 473, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2105, "impact_of_loft_insulation": -1681, "impact_of_solid_wall_insulation": -10424, "space_heating_existing_dwelling": 21851}, "energy_consumption_current": 319, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 5870081820, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SM6 7JF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLINGTON", "built_form": 2, "created_at": "2017-09-18 12:57:00", "door_count": 1, "glazed_area": 2, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17123}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Leechcroft Road", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-08-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 24.6, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 38.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.57, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 8.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 784, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 602, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 186, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2945, "impact_of_loft_insulation": -1118, "impact_of_solid_wall_insulation": -3878, "space_heating_existing_dwelling": 13436}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 10002364439, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"addendum_numbers": [11]}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "YO15 3HY", "hot_water": {"description": {"value": "No system present: electric immersion assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRIDLINGTON", "built_form": 4, "created_at": "2017-06-13 13:13:51.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 999, "water_heating_fuel": 0, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "No system present: electric heaters assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "44, Windsor Crescent", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-05-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 4, "heat_loss_corridor": 0}, "total_floor_area": 35, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 0, "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 34.98, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 715, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 211, "currency": "GBP"}, "hot_water_cost_current": {"value": 459, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.3, "energy_rating_potential": 57, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 459, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2954, "impact_of_loft_insulation": -404, "impact_of_solid_wall_insulation": -1758, "space_heating_existing_dwelling": 4599}, "energy_consumption_current": 693, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 394, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "F", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 117, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100011789100, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [1], "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WN2 5JT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIGAN", "built_form": 4, "created_at": "2017-04-22 21:07:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "207, Lily Lane", "address_line_2": "Bamfurlong", "assessment_type": "RdSAP", "completion_date": "2017-04-22", "inspection_date": "2017-04-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.7, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 38.7, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.15, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.2, "quantity": "square metres"}, "party_wall_length": {"value": 3.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 762, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 683, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2148, "impact_of_loft_insulation": -3622, "impact_of_cavity_insulation": -930, "space_heating_existing_dwelling": 11102}, "energy_consumption_current": 285, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 180, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 200001598039, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF43 3HW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FERNDALE", "built_form": 4, "created_at": "2017-08-02 09:05:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1839}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "42, Edmondes Street", "address_line_2": "Tylorstown", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-08-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.41, "quantity": "square metres"}, "party_wall_length": {"value": 8.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 27.41, "quantity": "square metres"}, "party_wall_length": {"value": 8.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.89, "quantity": "square metres"}, "party_wall_length": {"value": 4.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 1245, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 869, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 252, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 45}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2107, "impact_of_loft_insulation": -1763, "impact_of_cavity_insulation": -1179, "impact_of_solid_wall_insulation": -4085, "space_heating_existing_dwelling": 17695}, "energy_consumption_current": 473, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.92, "energy_consumption_potential": 250, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 200004285709, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NR7 0AR", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NORWICH", "built_form": 1, "created_at": "2017-08-22 15:37:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "132, St. Williams Way", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 154, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 65.3, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.52, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1319, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 147, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 736, "currency": "GBP"}, "hot_water_cost_current": {"value": 265, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 70, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 52}, {"sequence": 6, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 366, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 8, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 9, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 178, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 440, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3672, "impact_of_loft_insulation": -790, "space_heating_existing_dwelling": 17986}, "energy_consumption_current": 305, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 70, "calculation_software_version": "1.0.x", "energy_consumption_potential": 112, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200000899568, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ME5 7EL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHATHAM", "built_form": 4, "created_at": "2017-08-22 18:33:38.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15700}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "72, Rainham Road", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.465, "quantity": "square metres"}, "party_wall_length": {"value": 14.46, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.325, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.592, "quantity": "metres"}, "total_floor_area": {"value": 29.915, "quantity": "square metres"}, "party_wall_length": {"value": 14.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.356, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.292, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.81, "quantity": "square metres"}, "party_wall_length": {"value": 6.089, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.089, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.461, "quantity": "metres"}, "total_floor_area": {"value": 14.682, "quantity": "square metres"}, "party_wall_length": {"value": 6.072, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.66, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.986, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 874, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 619, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 224, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2216, "impact_of_loft_insulation": -1139, "impact_of_solid_wall_insulation": -5159, "space_heating_existing_dwelling": 16534}, "energy_consumption_current": 293, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 134, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100110015418, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS26 9PP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HARTLEPOOL", "built_form": 2, "created_at": "2017-05-23 21:30:32.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1125}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "63, Hutton Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 309, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 11.2, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 7.02, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 42.83, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.02, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 119.97, "quantity": "square metres"}, "party_wall_length": {"value": 13.48, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.92, "quantity": "metres"}, "total_floor_area": {"value": 80.02, "quantity": "square metres"}, "party_wall_length": {"value": 4.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.87, "quantity": "metres"}, "total_floor_area": {"value": 4.11, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 6.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 33.5, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.91, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.61, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.83, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 23.98, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 17.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 4357, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 24, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 145, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 2206, "currency": "GBP"}, "hot_water_cost_current": {"value": 228, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 12, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 516, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 461, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 145, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 42}, {"sequence": 4, "typical_saving": {"value": 179, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 43}, {"sequence": 5, "typical_saving": {"value": 791, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 61}], "co2_emissions_potential": 11, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 145, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 184, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 88}, {"sequence": 3, "typical_saving": {"value": 643, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 51}], "hot_water_cost_potential": {"value": 138, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3394, "impact_of_loft_insulation": -6456, "impact_of_cavity_insulation": -7210, "impact_of_solid_wall_insulation": -2252, "space_heating_existing_dwelling": 66446}, "energy_consumption_current": 432, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "1.0.x", "energy_consumption_potential": 203, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "E", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100081051340, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG10 0PH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "READING", "built_form": 2, "created_at": "2017-06-22 20:30:42", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 126, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1 Oak Cottage", "address_line_2": "Hungerford Lane", "address_line_3": "Shurlock Row", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 129, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.93, "quantity": "square metres"}, "party_wall_length": {"value": 10.88, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 38.87, "quantity": "square metres"}, "party_wall_length": {"value": 10.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.31, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 14.34, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.73, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 10.13, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 6.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 799, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 543, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2758, "impact_of_loft_insulation": -379, "impact_of_solid_wall_insulation": -3083, "space_heating_existing_dwelling": 14099}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 90, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 38161726, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "L11 3AN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2017-05-22 16:17:25.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "57, Wellesbourne Road", "assessment_type": "RdSAP", "completion_date": "2017-05-22", "inspection_date": "2017-05-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.78, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 33.76, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.02, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 613, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 557, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.9, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2051, "impact_of_loft_insulation": -2994, "space_heating_existing_dwelling": 10207}, "energy_consumption_current": 261, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 144, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 38079798, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L25 9ND", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2017-05-23 19:04:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5922}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "251, Hunts Cross Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-22", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "false", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.27, "quantity": "square metres"}, "party_wall_length": {"value": 7.14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 43.27, "quantity": "square metres"}, "party_wall_length": {"value": 7.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.42, "quantity": "square metres"}, "party_wall_length": {"value": 2.07, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 8.9, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 5.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.29, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.14, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 989, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 652, "currency": "GBP"}, "hot_water_cost_current": {"value": 205, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 185, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3367, "impact_of_loft_insulation": -446, "impact_of_solid_wall_insulation": -2642, "space_heating_existing_dwelling": 15350}, "energy_consumption_current": 253, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 63002041, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF9 2US", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PONTEFRACT", "built_form": 2, "created_at": "2017-06-26 10:15:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 192, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "4, Almond Close", "address_line_2": "South Elmsall", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 940, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 683, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.2, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 187, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1892, "impact_of_loft_insulation": -350, "space_heating_existing_dwelling": 7167}, "energy_consumption_current": 506, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 325, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 85, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N15 3EH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-08-22 11:41:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "80a Carlingford Road", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.11, "quantity": "square metres"}, "party_wall_length": {"value": 23.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 489, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 239, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 160, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1782, "impact_of_solid_wall_insulation": -2787, "space_heating_existing_dwelling": 6605}, "energy_consumption_current": 286, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 138, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 44048685, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME5 0JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHATHAM", "built_form": 4, "created_at": "2017-09-28 17:40:24.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Mountbatten Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 401, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2713, "space_heating_existing_dwelling": 6256}, "energy_consumption_current": 169, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100071536476, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY3 0PU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHREWSBURY", "built_form": 2, "created_at": "2017-08-22 17:58:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8641}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Meadowbrook", "address_line_2": "Bayston Hill", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.98, "quantity": "square metres"}, "party_wall_length": {"value": 7.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.94, "quantity": "square metres"}, "party_wall_length": {"value": 7.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 582, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 479, "currency": "GBP"}, "hot_water_cost_current": {"value": 149, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2647, "space_heating_existing_dwelling": 8800}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 102, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 207010647, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N13 4UN", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-04-22 16:13:02.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "9 Elmdale Road", "assessment_type": "RdSAP", "completion_date": "2017-04-22", "inspection_date": "2017-04-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 26, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-04-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.52, "quantity": "square metres"}, "party_wall_length": {"value": 10.88, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 273, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 21, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 177, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1648, "impact_of_solid_wall_insulation": -1207, "space_heating_existing_dwelling": 3061}, "energy_consumption_current": 348, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 234, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050573803, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "YO31 8NP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 3, "created_at": "2017-08-28 23:12:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17991}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Neville Street", "assessment_type": "RdSAP", "completion_date": "2017-08-28", "inspection_date": "2017-08-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.16, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 31.32, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.65, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 6.65, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.22, "quantity": "square metres"}, "party_wall_length": {"value": 2.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 851, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 514, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 58, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2086, "impact_of_loft_insulation": -1123, "impact_of_cavity_insulation": -409, "impact_of_solid_wall_insulation": -6322, "space_heating_existing_dwelling": 16247}, "energy_consumption_current": 337, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 65, "calculation_software_version": "9.0.0", "energy_consumption_potential": 128, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100090806392, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR10 3QS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORWICH", "built_form": 2, "created_at": "2017-05-24 12:57:17.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Giles Road", "address_line_2": "Spixworth", "assessment_type": "RdSAP", "completion_date": "2017-05-24", "inspection_date": "2017-05-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 4, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 3.8, "quantity": "square metres"}, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": {"value": 8.8, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.63, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 23.66, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 523, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 493, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1947, "impact_of_loft_insulation": -303, "space_heating_existing_dwelling": 8707}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 140, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100070043583, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY3 9DE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHREWSBURY", "built_form": 2, "created_at": "2017-09-24 10:58:33", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16919}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Grangefields", "assessment_type": "RdSAP", "completion_date": "2017-09-24", "inspection_date": "2017-09-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 296, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.53, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 45.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.57, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 674, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 616, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2097, "space_heating_existing_dwelling": 9878}, "energy_consumption_current": 204, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100110538291, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DL3 8DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DARLINGTON", "built_form": 2, "created_at": "2017-07-25 09:31:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15979}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Carmel Road South", "assessment_type": "RdSAP", "completion_date": "2017-07-25", "inspection_date": "2017-07-22", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 18.74, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.551, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.47, "quantity": "square metres"}, "party_wall_length": {"value": 6.83, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.593, "quantity": "metres"}, "total_floor_area": {"value": 13.863, "quantity": "square metres"}, "party_wall_length": {"value": 6.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.09, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.89, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.21, "quantity": "square metres"}, "party_wall_length": {"value": 4.381, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.528, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.551, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.576, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 8, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_alternative_wall": {"wall_area": 3.88, "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.562, "quantity": "metres"}, "total_floor_area": {"value": 4.607, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 4.298, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1039, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1005, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "co2_emissions_potential": 4.0, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2272, "impact_of_loft_insulation": -2647, "impact_of_cavity_insulation": -366, "space_heating_existing_dwelling": 16322}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 77, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 208, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 10014559376, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DL16 6LL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SPENNYMOOR", "built_form": 4, "created_at": "2017-09-22 16:49:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 The Old Clubhouse", "address_line_2": "2, Tudhoe Lane", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 46, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.15, "quantity": "square metres"}, "party_wall_length": {"value": 16.02, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 198, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 202, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1712, "space_heating_existing_dwelling": 1829}, "energy_consumption_current": 145, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 136, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100091142842, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "IP12 1LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOODBRIDGE", "built_form": 1, "created_at": "2017-07-23 21:40:15.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8788}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "58, Bury Hill Close", "assessment_type": "RdSAP", "completion_date": "2017-07-23", "inspection_date": "2017-07-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 122, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 47.3, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "G", "roof_insulation_thickness": "250mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 37.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 1, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 731, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 615, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 142, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2967, "impact_of_loft_insulation": -286, "space_heating_existing_dwelling": 11625}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 106, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 23055101, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OL11 1SU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROCHDALE", "built_form": 2, "created_at": "2017-08-23 10:32:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 29 Stoneyvale Court", "address_line_2": "Dicken Green Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-23", "inspection_date": "2017-08-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 80.52, "quantity": "square metres"}, "party_wall_length": {"value": 8.15, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 555, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 497, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.9, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2261, "space_heating_existing_dwelling": 9652}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 201, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100062141768, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RH6 7AT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORLEY", "built_form": 3, "created_at": "2017-06-27 18:11:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16404}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, The Orchard", "address_line_2": "Victoria Road", "assessment_type": "RdSAP", "completion_date": "2017-06-27", "inspection_date": "2017-06-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 140, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-06-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.56, "quantity": "square metres"}, "party_wall_length": {"value": 8.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 36.59, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.52, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 34.89, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.52, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.54, "quantity": "square metres"}, "party_wall_length": {"value": 0.55, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 11.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 17.52, "quantity": "square metres"}, "party_wall_length": {"value": 0.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1088, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1014, "currency": "GBP"}, "hot_water_cost_current": {"value": 154, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 92, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "co2_emissions_potential": 4.0, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3154, "space_heating_existing_dwelling": 16961}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "9.0.0", "energy_consumption_potential": 162, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050056164, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO25 5YW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DRIFFIELD", "built_form": 1, "created_at": "2017-04-28 12:01:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15241}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "33, Whitelands", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 77.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 38.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 565, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 528, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2788, "space_heating_existing_dwelling": 8560}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 133, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110270520, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CA3 9SQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARLISLE", "built_form": 2, "created_at": "2017-07-27 15:28:16.000000", "door_count": 2, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "15, Ash Grove", "assessment_type": "RdSAP", "completion_date": "2017-07-27", "inspection_date": "2017-07-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.61, "quantity": "square metres"}, "party_wall_length": {"value": 8.47, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.21, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 356, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 310, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.5, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1837, "space_heating_existing_dwelling": 4247}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 219, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031342905, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG9 7BE", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2017-06-27 09:44:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "45, Wellington Street", "address_line_2": "Stapleford", "assessment_type": "RdSAP", "completion_date": "2017-06-27", "inspection_date": "2017-06-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.36, "quantity": "square metres"}, "party_wall_length": {"value": 8.51, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1150, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 442, "currency": "GBP"}, "hot_water_cost_current": {"value": 267, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 666, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 570, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 86}, {"sequence": 2, "typical_saving": {"value": 600, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 712, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1715, "space_heating_existing_dwelling": 6371}, "energy_consumption_current": 497, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 126, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 85, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 3455046060, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST3 5ST", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2017-09-27 13:42:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15206}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Harington Drive", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 12.1, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 8.7, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 691, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 664, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2090, "space_heating_existing_dwelling": 9945}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 167, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 200004014457, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN13 3QW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORTHING", "built_form": 3, "created_at": "2017-07-31 08:01:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 3, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "34, Bridgnorth Close", "assessment_type": "RdSAP", "completion_date": "2017-07-31", "inspection_date": "2017-07-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 3, "registration_date": "2017-07-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.74, "quantity": "square metres"}, "party_wall_length": {"value": 5.67, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 30.74, "quantity": "square metres"}, "party_wall_length": {"value": 5.67, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 441, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1698, "impact_of_loft_insulation": -354, "space_heating_existing_dwelling": 7369}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10091605835, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully triple glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE65 0FB", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MORPETH", "built_form": 1, "created_at": "2017-04-28 08:13:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2705, "main_heating_category": 8, "main_heating_fraction": 1, "sap_main_heating_code": 424, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric underfloor heating", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 2 Coble Quay", "address_line_2": "Amble", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 93.41, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 510, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Temperature zone control", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 6, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 510, "currency": "GBP"}, "hot_water_cost_current": {"value": 214, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 214, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1374, "space_heating_existing_dwelling": 3280}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 167, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100020688957, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR2 6JT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTH CROYDON", "built_form": 4, "created_at": "2017-04-29 18:43:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "16, Wilson Close", "assessment_type": "RdSAP", "completion_date": "2017-04-29", "inspection_date": "2017-04-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.1, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 62.5, "quantity": "square metres"}, "party_wall_length": {"value": 16.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 185, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 187, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1897, "space_heating_existing_dwelling": 1392}, "energy_consumption_current": 108, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "B", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 19, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10024203967, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL30 1DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LLANDUDNO", "built_form": 2, "created_at": "2017-04-26 10:43:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "17, Victoria Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-26", "inspection_date": "2017-03-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 74, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.5, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 408, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 353, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2044, "space_heating_existing_dwelling": 5848}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 158, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 21016143, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU5 4EU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 3, "created_at": "2017-10-24 16:18:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "107, Bricknell Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.66, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 37.25, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1083, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 631, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 366, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2200, "impact_of_loft_insulation": -1137, "impact_of_cavity_insulation": -246, "impact_of_solid_wall_insulation": -6905, "space_heating_existing_dwelling": 18001}, "energy_consumption_current": 367, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 148, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 5870077074, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SM6 0PY", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WALLINGTON", "built_form": 2, "created_at": "2017-09-28 18:03:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 15 Jasmine Court", "address_line_2": "138, Woodcote Road", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 5.0}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1165, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.9, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 824, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 342, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 31}], "co2_emissions_potential": 6.2, "energy_rating_potential": 51, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 548, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 423, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 59}], "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1889, "space_heating_existing_dwelling": 12545}, "energy_consumption_current": 674, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 527, "environmental_impact_current": 20, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "F", "environmental_impact_potential": 31, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 114, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 83070381, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HD1 6PP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 4, "created_at": "2017-04-26 21:38:27.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9955}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "11, Town Place", "assessment_type": "RdSAP", "completion_date": "2017-04-26", "inspection_date": "2017-04-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 60.18, "quantity": "square metres"}, "party_wall_length": {"value": 16.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 408, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 293, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}}], "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1862, "impact_of_loft_insulation": -416, "impact_of_cavity_insulation": -1837, "space_heating_existing_dwelling": 5794}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 153, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100010723240, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "FY5 4PP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "THORNTON-CLEVELEYS", "built_form": 2, "created_at": "2017-07-24 15:18:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15087}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "95, Lawsons Road", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 34.29, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.01, "quantity": "square metres"}, "party_wall_length": {"value": 8.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 508, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 465, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2697, "space_heating_existing_dwelling": 8388}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 100, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100081011030, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LU2 7GL", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LUTON", "built_form": 4, "created_at": "2017-07-24 21:11:50.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 32 Popes Court", "address_line_2": "Old Bedford Road", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 51.14, "quantity": "square metres"}, "party_wall_length": {"value": 16.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 115, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 87, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 116, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1728, "space_heating_existing_dwelling": 1046}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "B", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100062144479, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH2 0BL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "REIGATE", "built_form": 2, "created_at": "2017-10-24 16:35:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17317}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2 Old School House", "address_line_2": "Mark Street", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 135, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.81, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 4.3, "quantity": "metres"}, "total_floor_area": {"value": 67.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 921, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 762, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2966, "impact_of_loft_insulation": -378, "space_heating_existing_dwelling": 17737}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 134, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100100351024, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SA1 6BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWANSEA", "built_form": 4, "created_at": "2017-07-24 20:42:30.000000", "door_count": 3, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17663}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Brooklands Terrace", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 213, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.3, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 47.3, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 33.39, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.35, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1565, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 164, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 985, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 4.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2219, "impact_of_loft_insulation": -3427, "impact_of_cavity_insulation": -2952, "impact_of_solid_wall_insulation": -1427, "space_heating_existing_dwelling": 29020}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 117, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10007372752, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HR2 9JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HEREFORD", "built_form": 1, "created_at": "2017-08-26 15:20:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 10618}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Pope Place", "address_line_2": "Preston-on-Wye", "assessment_type": "RdSAP", "completion_date": "2017-08-26", "inspection_date": "2017-08-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 457, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 12, "pvc_window_frames": "true", "registration_date": "2017-08-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, coal", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 253, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 223.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 60.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 221.45, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 64.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 322, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.22, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 12, "heating_cost_current": {"value": 3139, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 26, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 207, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1847, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 1144, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 61}], "co2_emissions_potential": 13, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 207, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 162, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3470, "impact_of_loft_insulation": -652, "impact_of_cavity_insulation": -946, "impact_of_solid_wall_insulation": -21940, "space_heating_existing_dwelling": 58860}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "E", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100050528511, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "YO19 6NS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 1, "created_at": "2017-06-25 08:47:46.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Romans Close", "address_line_2": "Riccall", "assessment_type": "RdSAP", "completion_date": "2017-06-25", "inspection_date": "2017-06-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 156, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-06-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 292, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.91, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 69.91, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 291, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.42, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 12.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 878, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 135, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 780, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 263, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2753, "impact_of_loft_insulation": -492, "space_heating_existing_dwelling": 12375}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100030229902, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S18 2GZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DRONFIELD", "built_form": 1, "created_at": "2017-08-25 10:52:15.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "28, Summerfield Road", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78.41, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.58, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 545, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2003, "space_heating_existing_dwelling": 9674}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 125, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100021077376, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 47% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E5 0QQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-04-27 11:24:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, Thistlewaite Road", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 214, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, smokeless fuel", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 25.63, "quantity": "square metres"}, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.02, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.04, "quantity": "metres"}, "total_floor_area": {"value": 48.61, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.49, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 3.03, "quantity": "metres"}, "total_floor_area": {"value": 48.61, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.85, "quantity": "square metres"}, "party_wall_length": {"value": 4.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 14.85, "quantity": "square metres"}, "party_wall_length": {"value": 4.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.86, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 14.85, "quantity": "square metres"}, "party_wall_length": {"value": 4.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 47, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1894, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 909, "currency": "GBP"}, "hot_water_cost_current": {"value": 192, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 504, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 67}], "co2_emissions_potential": 4.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 135, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 188, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 503, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3026, "impact_of_loft_insulation": -112, "impact_of_solid_wall_insulation": -7212, "space_heating_existing_dwelling": 25339}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100020629262, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully triple glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR0 5NX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CROYDON", "built_form": 4, "created_at": "2017-09-25 13:46:36.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Turnpike Link", "assessment_type": "RdSAP", "completion_date": "2017-09-25", "inspection_date": "2017-09-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 29.48, "wall_dry_lined": "N", "wall_thickness": 130, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.94, "quantity": "square metres"}, "party_wall_length": {"value": 10.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 26.79, "quantity": "square metres"}, "party_wall_length": {"value": 10.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.46, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 26.79, "quantity": "square metres"}, "party_wall_length": {"value": 10.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.46, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.13, "quantity": "square metres"}, "party_wall_length": {"value": 5.72, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 16.13, "quantity": "square metres"}, "party_wall_length": {"value": 5.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.82, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 674, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 6, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 572, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2400, "impact_of_solid_wall_insulation": -1623, "space_heating_existing_dwelling": 12272}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 108, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 1.8, "data_source": 2, "solar_transmittance": 0.68}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100090982598, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 39% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PE30 3JQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KING'S LYNN", "built_form": 1, "created_at": "2017-08-25 17:57:36.000000", "door_count": 3, "glazed_area": 4, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15017}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "sap_windows": [{"orientation": 5, "window_area": {"value": 5.75, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 6.92, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 7, "window_area": {"value": 0.62, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 1.43, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 0.54, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"orientation": 1, "window_area": {"value": 9.9, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 1.59, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Oak Avenue", "address_line_2": "South Wootton", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 37.36, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 49.45, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 39, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 816, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 682, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2929, "impact_of_loft_insulation": -2708, "impact_of_cavity_insulation": -1721, "space_heating_existing_dwelling": 14508}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 146, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 23, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100110172907, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TS19 0JT", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "STOCKTON-ON-TEES", "built_form": 2, "created_at": "2017-04-26 19:42:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16497}], "immersion_heating_type": 2, "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Dover Road", "assessment_type": "RdSAP", "completion_date": "2017-04-26", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.99, "quantity": "square metres"}, "party_wall_length": {"value": 7.95, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 51.99, "quantity": "square metres"}, "party_wall_length": {"value": 7.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.03, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1236, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 130, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No time or thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 761, "currency": "GBP"}, "hot_water_cost_current": {"value": 327, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 422, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 235, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 137, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 491, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2106, "impact_of_loft_insulation": -3559, "space_heating_existing_dwelling": 16342}, "energy_consumption_current": 405, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 168, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 38314458, "roofs": [{"description": {"value": "Pitched, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, with additional insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L6 4AH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2017-07-28 09:22:57.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10443}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "13 Preston Grove", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 24, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 8, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 24.37, "quantity": "square metres"}, "party_wall_length": {"value": 15.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.44, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "L", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 163, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.8, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 23, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 150, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 23, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1369, "space_heating_existing_dwelling": 762}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 165, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 3, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100022678045, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 8% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW11 1LT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-08-10 18:45:59.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8640}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "42, Parma Crescent", "assessment_type": "RdSAP", "completion_date": "2017-08-10", "inspection_date": "2017-07-25", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 139, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-08-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.88, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.944, "quantity": "square metres"}, "party_wall_length": {"value": 15.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.347, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 43.637, "quantity": "square metres"}, "party_wall_length": {"value": 15.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.647, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.417, "quantity": "square metres"}, "party_wall_length": {"value": 5.85, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.16, "quantity": "metres"}, "total_floor_area": {"value": 20.417, "quantity": "square metres"}, "party_wall_length": {"value": 5.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.34, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.01, "quantity": "metres"}, "total_floor_area": {"value": 20.417, "quantity": "square metres"}, "party_wall_length": {"value": 5.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.19, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.399, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1195, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 749, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a3120", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 3.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2984, "impact_of_loft_insulation": -2883, "impact_of_solid_wall_insulation": -5484, "space_heating_existing_dwelling": 20922}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200004348627, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR2 4LE", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NORWICH", "built_form": 3, "created_at": "2017-04-25 16:16:17.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "17, Watson Grove", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.8, "quantity": "metres"}}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.32, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 46.8, "quantity": "square metres"}, "party_wall_length": {"value": 4.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.92, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 514, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 233, "currency": "GBP"}, "hot_water_cost_current": {"value": 244, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 345, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 374, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 350, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 274, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1571, "impact_of_loft_insulation": -497, "impact_of_cavity_insulation": -63, "space_heating_existing_dwelling": 3307}, "energy_consumption_current": 340, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 170, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100060255163, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 10% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "RG26 3UL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TADLEY", "built_form": 2, "created_at": "2017-04-27 01:32:22.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10164}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Minstead Close", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 411, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 383, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2834, "impact_of_loft_insulation": -480, "space_heating_existing_dwelling": 6074}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 72, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100061709172, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO22 7TS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOGNOR REGIS", "built_form": 1, "created_at": "2017-05-26 06:48:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, West Drive", "address_line_2": "Elmer", "assessment_type": "RdSAP", "completion_date": "2017-05-26", "inspection_date": "2017-05-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 48.38, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.67, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.43, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1079, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 836, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 206, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 55}}], "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2744, "impact_of_loft_insulation": -3602, "impact_of_cavity_insulation": -4231, "space_heating_existing_dwelling": 18755}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 157, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100040425317, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL7 1XR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 1, "created_at": "2017-05-25 12:55:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Collaford Close", "assessment_type": "RdSAP", "completion_date": "2017-05-25", "inspection_date": "2017-05-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-05-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 30.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 50.24, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 642, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 504, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2243, "impact_of_loft_insulation": -1102, "space_heating_existing_dwelling": 11239}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 91, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100031216669, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN29 7DE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLINGBOROUGH", "built_form": 2, "created_at": "2017-07-25 20:27:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17055}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Wollaston Road", "address_line_2": "Irchester", "assessment_type": "RdSAP", "completion_date": "2017-07-25", "inspection_date": "2017-07-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.92, "quantity": "square metres"}, "party_wall_length": {"value": 7.26, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 25.92, "quantity": "square metres"}, "party_wall_length": {"value": 7.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.63, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 16.63, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.42, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1005, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 548, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 358, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1981, "impact_of_solid_wall_insulation": -6557, "space_heating_existing_dwelling": 16389}, "energy_consumption_current": 331, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 114, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100031218860, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG17 7QA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2017-10-25 16:36:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Ashwood Avenue", "address_line_2": "Kirkby-in-Ashfield", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 42.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 541, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 502, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2157, "space_heating_existing_dwelling": 9347}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 46003865, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E6 2LT", "hot_water": {"description": {"value": "No system present: electric immersion assumed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-07-26 20:34:28.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 999, "water_heating_fuel": 0, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3 Malyon Court", "address_line_2": "488, Barking Road", "assessment_type": "RdSAP", "completion_date": "2017-07-26", "inspection_date": "2017-07-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.1, "quantity": "metres"}}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.84, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 57.71, "quantity": "square metres"}, "party_wall_length": {"value": 13.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 173, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 137, "currency": "GBP"}, "hot_water_cost_current": {"value": 261, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 203, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 182, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 261, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1914, "space_heating_existing_dwelling": 1887}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 201, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050489187, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO13 9HA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SCARBOROUGH", "built_form": 1, "created_at": "2017-07-26 18:13:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Seavegate", "address_line_2": "East Ayton", "assessment_type": "RdSAP", "completion_date": "2017-07-26", "inspection_date": "2017-07-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 120, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-07-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 37.76, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "Y", "construction_age_band": "E", "roof_insulation_thickness": "270mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.57, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 13.73, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "G"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.34, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.93, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1157, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 753, "currency": "GBP"}, "hot_water_cost_current": {"value": 212, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 234, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 346, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3189, "impact_of_loft_insulation": -510, "space_heating_existing_dwelling": 15851}, "energy_consumption_current": 330, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 145, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100030349516, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 9% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DE22 4FN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 2, "created_at": "2017-05-27 13:57:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 833}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "150, Prince Charles Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-27", "inspection_date": "2017-05-26", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.24, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 45.24, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 9, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 614, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 434, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2093, "impact_of_loft_insulation": -433, "space_heating_existing_dwelling": 7704}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 94, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100100489844, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 45% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF33 6LP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIDGEND", "built_form": 2, "created_at": "2017-08-01 08:59:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "42, Pyle Inn Way", "address_line_2": "Pyle", "assessment_type": "RdSAP", "completion_date": "2017-08-01", "inspection_date": "2017-07-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.396, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.687, "quantity": "square metres"}, "party_wall_length": {"value": 5.463, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.357, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.411, "quantity": "metres"}, "total_floor_area": {"value": 40.687, "quantity": "square metres"}, "party_wall_length": {"value": 5.463, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.357, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 686, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 396, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 54, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 9, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2122, "impact_of_loft_insulation": -444, "space_heating_existing_dwelling": 8929}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 72, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100100217163, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH4 8SF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTER", "built_form": 2, "created_at": "2017-04-27 11:02:57.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5987}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "80, High Street", "address_line_2": "Saltney", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 16.81, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.51, "quantity": "square metres"}, "party_wall_length": {"value": 10.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.51, "quantity": "square metres"}, "party_wall_length": {"value": 10.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1341, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 566, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 237, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 372, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2266, "impact_of_loft_insulation": -117, "impact_of_solid_wall_insulation": -6111, "space_heating_existing_dwelling": 21372}, "energy_consumption_current": 377, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 108, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100030414649, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE7 7BR", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-09-27 07:51:23.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 609, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "175, Cropston Road", "address_line_2": "Anstey", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.51, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 41.51, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1204, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.6, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 389, "currency": "GBP"}, "hot_water_cost_current": {"value": 330, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 448, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 435, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 7, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 402, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 335, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 415, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2376, "impact_of_loft_insulation": -422, "impact_of_solid_wall_insulation": -5457, "space_heating_existing_dwelling": 13487}, "energy_consumption_current": 458, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 79, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100100419447, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LL29 7HB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLWYN BAY", "built_form": 2, "created_at": "2017-06-26 18:18:49.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16740}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Seafield Road", "assessment_type": "RdSAP", "completion_date": "2017-06-26", "inspection_date": "2017-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 155, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 35.36, "wall_dry_lined": "N", "wall_thickness": 450, "wall_construction": 1, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.87, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 59.56, "quantity": "square metres"}, "party_wall_length": {"value": 7.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.68, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 54.78, "quantity": "square metres"}, "party_wall_length": {"value": 7.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1656, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 880, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 696, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.5, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2257, "impact_of_solid_wall_insulation": -11593, "space_heating_existing_dwelling": 25554}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 129, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100121007553, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN14 8QA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHIPPENHAM", "built_form": 4, "created_at": "2017-10-26 12:52:24.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Hazel Way", "address_line_2": "North Colerne", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-26", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 457, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 426, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}, {"sequence": 4, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 108, "environmental_impact_rating": 104}], "co2_emissions_potential": -0.5, "energy_rating_potential": 108, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2137, "space_heating_existing_dwelling": 7153}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": -44, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 104, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100031348532, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG4 3QJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2017-04-28 18:02:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16919}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Bracken Close", "address_line_2": "Carlton", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 24.58, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.18, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 13.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 509, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 457, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2043, "space_heating_existing_dwelling": 8426}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 5300022533, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N1 9DF", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-04-27 05:41:16.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 73 Kendal House", "address_line_2": "Collier Street", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 67.31, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.29, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 316, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 316, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 136, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2292, "space_heating_existing_dwelling": 3792}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 177, "environmental_impact_current": 98, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 98, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100021188923, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N22 6QG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-05-30 20:29:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10321}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "182, Hewitt Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-30", "inspection_date": "2017-05-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.19, "quantity": "square metres"}, "party_wall_length": {"value": 13.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 29.59, "quantity": "square metres"}, "party_wall_length": {"value": 13.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.67, "quantity": "square metres"}, "party_wall_length": {"value": 3.69, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.76, "quantity": "metres"}, "total_floor_area": {"value": 9.67, "quantity": "square metres"}, "party_wall_length": {"value": 3.69, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.36, "quantity": "square metres"}, "party_wall_length": {"value": 0.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 567, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 391, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 180, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2678, "impact_of_loft_insulation": -355, "impact_of_solid_wall_insulation": -3940, "space_heating_existing_dwelling": 9677}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 77, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100051269346, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BD20 6DJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "KEIGHLEY", "built_form": 2, "created_at": "2017-09-26 16:52:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Parkers Lane", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.93, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 36.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 970, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 493, "currency": "GBP"}, "hot_water_cost_current": {"value": 276, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 103, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3449, "impact_of_cavity_insulation": -3631, "space_heating_existing_dwelling": 11642}, "energy_consumption_current": 481, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 130, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 85, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100031765243, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST16 2EW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 4, "created_at": "2017-05-24 07:49:32.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8360}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Doxey Road", "assessment_type": "RdSAP", "completion_date": "2017-05-24", "inspection_date": "2017-05-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.92, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 25.92, "quantity": "square metres"}, "party_wall_length": {"value": 14.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 554, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 298, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 179, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.5, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1730, "impact_of_solid_wall_insulation": -2939, "space_heating_existing_dwelling": 7071}, "energy_consumption_current": 323, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 51, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100022241348, "roofs": [{"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG1 4RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ILFORD", "built_form": 4, "created_at": "2017-08-24 00:12:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 843}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "12, Toronto Road", "assessment_type": "RdSAP", "completion_date": "2017-08-24", "inspection_date": "2017-08-23", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 44, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-08-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.5, "quantity": "square metres"}, "party_wall_length": {"value": 13, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 603, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 33, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 242, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1606, "impact_of_cavity_insulation": -724, "impact_of_solid_wall_insulation": -1632, "space_heating_existing_dwelling": 7283}, "energy_consumption_current": 428, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 165, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100061324996, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 32% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "KT7 0JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "THAMES DITTON", "built_form": 3, "created_at": "2017-10-23 14:19:55", "door_count": 7, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16834}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Admiral Manor", "address_line_2": "Weston Green", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-23", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 226, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 390, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58, "quantity": "square metres"}, "party_wall_length": {"value": 8.95, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 58, "quantity": "square metres"}, "party_wall_length": {"value": 8.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 8, "roof_construction": 4, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 55.25, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 32, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1771, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.8, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 169, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 913, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 454, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 103, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 144, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3013, "impact_of_solid_wall_insulation": -8793, "space_heating_existing_dwelling": 34103}, "energy_consumption_current": 245, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 22, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 2465001057, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 47% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LE5 2AR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-09-25 14:13:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16696}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "75, Peters Drive", "assessment_type": "RdSAP", "completion_date": "2017-09-25", "inspection_date": "2017-09-23", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 111, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.54, "quantity": "square metres"}, "party_wall_length": {"value": 9.15, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 58.54, "quantity": "square metres"}, "party_wall_length": {"value": 9.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.88, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 47, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 700, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 654, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2259, "impact_of_loft_insulation": -822, "space_heating_existing_dwelling": 11303}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 132, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100090581395, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SS6 7TD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "RAYLEIGH", "built_form": 2, "created_at": "2017-06-23 08:38:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "29, Hilltop Close", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 105, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 42.34, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "D", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.37, "quantity": "square metres"}, "party_wall_length": {"value": 9.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1288, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 843, "currency": "GBP"}, "hot_water_cost_current": {"value": 184, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 42}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.4, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 356, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 55}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2713, "impact_of_solid_wall_insulation": -2054, "space_heating_existing_dwelling": 18916}, "energy_consumption_current": 395, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 184, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100030230237, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "S21 3WL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 2, "created_at": "2017-05-31 09:13:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, The Wynd", "address_line_2": "Renishaw", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2016-11-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 10, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 43.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.82, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 507, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 464, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2300, "space_heating_existing_dwelling": 6687}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 90, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100040525085, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ4 7BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PAIGNTON", "built_form": 2, "created_at": "2017-05-23 17:28:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10338}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Haytor Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.62, "quantity": "square metres"}, "party_wall_length": {"value": 8.21, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 32.15, "quantity": "square metres"}, "party_wall_length": {"value": 8.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 482, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2270, "impact_of_loft_insulation": -336, "space_heating_existing_dwelling": 7865}, "energy_consumption_current": 145, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 79, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100030038519, "roofs": [{"description": {"value": "Pitched, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Sandstone or limestone, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DE5 3RQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RIPLEY", "built_form": 2, "created_at": "2017-05-23 20:50:02.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10450}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Bridle Lane", "address_line_2": "Lower Hartshay", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-23", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 199, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 8, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 83.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 34.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 4.1, "quantity": "metres"}, "total_floor_area": {"value": 74.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.7, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "150mm", "sloping_ceiling_insulation_thickness": "150mm"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 1000, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 938, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 164, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 950, "currency": "GBP"}, "hot_water_cost_current": {"value": 175, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3175", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 4.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 95, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 175, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3582, "impact_of_solid_wall_insulation": -864, "space_heating_existing_dwelling": 18218}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 133, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 48, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100011000922, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "M45 7RJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2017-05-27 00:15:45.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "45, Nipper Lane", "address_line_2": "Whitefield", "assessment_type": "RdSAP", "completion_date": "2017-05-27", "inspection_date": "2017-05-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 24.14, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.82, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.67, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.83, "quantity": "metres"}, "total_floor_area": {"value": 35.67, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 804, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 807, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1925, "impact_of_loft_insulation": -963, "space_heating_existing_dwelling": 14741}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 194, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10091700360, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WN7 2RY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEIGH", "built_form": 3, "created_at": "2017-08-02 18:10:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 11 College House", "address_line_2": "College Street", "assessment_type": "RdSAP", "completion_date": "2017-08-02", "inspection_date": "2017-07-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 81.6, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 310, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 272, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 88, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2124, "space_heating_existing_dwelling": 3522}, "energy_consumption_current": 137, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 115, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100091284188, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SS9 4LW", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LEIGH-ON-SEA", "built_form": 4, "created_at": "2017-07-28 09:25:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "3, Orchard Mead", "address_line_2": "Eastwood Road North", "assessment_type": "RdSAP", "completion_date": "2017-07-28", "inspection_date": "2017-07-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1, "unheated_corridor_length": 0}, "total_floor_area": 42, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-07-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.57, "quantity": "square metres"}, "party_wall_length": {"value": 10.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 218, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 148, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1513, "space_heating_existing_dwelling": 2409}, "energy_consumption_current": 314, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 254, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100030154157, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NG10 5FZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2017-09-28 19:27:58", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 4, "main_heating_number": 1, "main_heating_control": 2204, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "true", "main_heating_data_source": 1, "main_heating_index_number": 100053}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, radiators, electric", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "15, Melton Court", "address_line_2": "Sandiacre", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-28", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 56, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 46.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 336, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 315, "currency": "GBP"}, "hot_water_cost_current": {"value": 336, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.3, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 336, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2465, "space_heating_existing_dwelling": 6589}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 239, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100032117150, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NG3 4JF", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2017-06-28 18:39:08.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5901}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2 Bungalow", "address_line_2": "398, Woodborough Road", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.94, "quantity": "square metres"}, "party_wall_length": {"value": 5.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 615, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 474, "currency": "GBP"}, "hot_water_cost_current": {"value": 203, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 89, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 127, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 56}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3055, "impact_of_loft_insulation": -3758, "space_heating_existing_dwelling": 8098}, "energy_consumption_current": 540, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 193, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 95, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200000984522, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WA3 5NX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WARRINGTON", "built_form": 4, "created_at": "2017-06-28 19:38:58.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "466, Warrington Road", "address_line_2": "Leigh End", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.8, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 30.8, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 679, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 379, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1951, "impact_of_loft_insulation": -580, "impact_of_solid_wall_insulation": -2886, "space_heating_existing_dwelling": 8226}, "energy_consumption_current": 321, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100022797807, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [1]}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "W2 4SA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-06-29 13:44:26.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2039}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat J", "address_line_2": "26 Redan Place", "assessment_type": "RdSAP", "completion_date": "2017-06-29", "inspection_date": "2017-06-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 1}, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 76.17, "quantity": "square metres"}, "party_wall_length": {"value": 9.11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 220, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 216, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2872, "space_heating_existing_dwelling": 1932}, "energy_consumption_current": 137, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 11063247, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DN34 5LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 2, "created_at": "2017-10-10 19:45:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Chepstow Grove", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-09-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.43, "quantity": "square metres"}, "party_wall_length": {"value": 5.573, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.339, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 37.43, "quantity": "square metres"}, "party_wall_length": {"value": 5.573, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.298, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.326, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.251, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.041, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 715, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 684, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1931, "impact_of_loft_insulation": -237, "space_heating_existing_dwelling": 13236}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 178, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 68150383, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH1 3JN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "REDHILL", "built_form": 2, "created_at": "2017-04-28 14:08:37.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "110, Mansfield Drive", "address_line_2": "Merstham", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.29, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 49.29, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 499, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 462, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3078, "space_heating_existing_dwelling": 7282}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 88, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10003928677, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Sandstone or limestone, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 84% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL15 2YE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "RUTHIN", "built_form": 1, "created_at": "2017-04-18 20:01:43.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 6, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 3}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 125, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Pentre Coch Manor", "address_line_2": "Pentre Coch", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-02-28", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 568, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 12, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 770, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 209.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 56.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 209.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 61.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 520, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 131.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 530, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 2, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 91.14, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 91.14, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 39.2, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 84, "solar_water_heating": "N", "habitable_room_count": 12, "heating_cost_current": {"value": 6791, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 49.4, "energy_rating_average": 60, "energy_rating_current": 18, "lighting_cost_current": {"value": 195, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 4093, "currency": "GBP"}, "hot_water_cost_current": {"value": 236, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 5, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 908, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 25, "environmental_impact_rating": 22}, {"sequence": 2, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 27, "environmental_impact_rating": 23}, {"sequence": 3, "typical_saving": {"value": 384, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 26}, {"sequence": 4, "typical_saving": {"value": 1138, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 36}, {"sequence": 5, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 38}, {"sequence": 6, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 39}, {"sequence": 7, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 42}], "co2_emissions_potential": 27.0, "energy_rating_potential": 52, "lighting_cost_potential": {"value": 199, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 147, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3527, "impact_of_loft_insulation": -12917, "impact_of_solid_wall_insulation": -14929, "space_heating_existing_dwelling": 105721}, "energy_consumption_current": 330, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 5, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 172, "environmental_impact_current": 17, "fixed_lighting_outlets_count": 96, "current_energy_efficiency_band": "G", "environmental_impact_potential": 42, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 87, "low_energy_fixed_lighting_outlets_count": 81} +{"uprn": 100031309533, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG9 3FB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2017-09-21 19:35:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8802}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Chesham Drive", "address_line_2": "Bramcote", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20, "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 403, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 348, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2373, "space_heating_existing_dwelling": 5533}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 73, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100100625343, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA8 4BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWANSEA", "built_form": 1, "created_at": "2017-04-23 22:00:17.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "261a, Swansea Road", "address_line_2": "Trebanos, Pontardawe", "assessment_type": "RdSAP", "completion_date": "2017-04-23", "inspection_date": "2017-04-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.47, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 40.56, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26.12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 548, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2386, "space_heating_existing_dwelling": 10631}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 45123123, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DH5 0HQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-06-01 06:31:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Bowes Avenue", "address_line_2": "Easington Lane", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.7, "quantity": "square metres"}, "party_wall_length": {"value": 5.72, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 481, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 335, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 8, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 39, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1528, "space_heating_existing_dwelling": 6719}, "energy_consumption_current": 372, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 83, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100030531161, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 42% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CV13 6HU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NUNEATON", "built_form": 2, "created_at": "2017-08-22 07:39:51.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31, Hinckley Road", "address_line_2": "Dadlington", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.87, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 29.87, "quantity": "square metres"}, "party_wall_length": {"value": 7.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 17.39, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 12.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 974, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 562, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 352, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2366, "impact_of_solid_wall_insulation": -7324, "space_heating_existing_dwelling": 17866}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 117, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100010578023, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 10% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PR3 5DH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRESTON", "built_form": 1, "created_at": "2017-07-23 09:16:36.000000", "door_count": 2, "glazed_area": 4, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16878}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 6, "window_area": {"value": 4.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 6, "window_area": {"value": 2.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 4.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 4, "window_area": {"value": 1.09, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 2.28, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 2, "window_area": {"value": 1.93, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 0.3, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "26, Willow Tree Avenue", "address_line_2": "Broughton", "assessment_type": "RdSAP", "completion_date": "2017-07-23", "inspection_date": "2017-07-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 35.69, "quantity": "square metres"}, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "270mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.94, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 26.73, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.37, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 888, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 732, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2264, "space_heating_existing_dwelling": 12562}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 158, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10011971908, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 10% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PE37 7QY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWAFFHAM", "built_form": 1, "created_at": "2017-07-21 14:37:13", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9582}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Cromwell Cottage", "address_line_2": "White Cross Road", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-07-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 149, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 30.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 67.33, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.54, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 720, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 178, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 732, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 93, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2318, "space_heating_existing_dwelling": 12287}, "energy_consumption_current": 162, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 117, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 14031808, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG4 6XN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 3, "created_at": "2017-08-22 16:45:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15016}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "18, Glebe Gardens", "address_line_2": "Sonning", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 62.19, "quantity": "square metres"}, "party_wall_length": {"value": 7.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 266, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 269, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2495, "space_heating_existing_dwelling": 3308}, "energy_consumption_current": 160, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 155, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100071318950, "roofs": [{"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV4 7JL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 4, "created_at": "2017-07-06 14:47:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8361}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "14, Lynchgate Court", "address_line_2": "Lynchgate Road", "assessment_type": "RdSAP", "completion_date": "2017-07-06", "inspection_date": "2017-06-21", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 54, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-07-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 44.3, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 8.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 3, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.6, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 9.3, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 0.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 629, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 333, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 25, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.7, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1758, "impact_of_cavity_insulation": -451, "space_heating_existing_dwelling": 9002}, "energy_consumption_current": 356, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 25, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 180, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 45116939, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE38 8EQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 2, "created_at": "2017-06-01 12:57:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "108, Stockley Road", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-02-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 377, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1783, "space_heating_existing_dwelling": 8116}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100100000206, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL68 9BG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AMLWCH", "built_form": 4, "created_at": "2017-10-16 15:28:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "63, Maes Llwyn", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-09-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.6, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.4, "quantity": "square metres"}, "party_wall_length": {"value": 2.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 459, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2131, "space_heating_existing_dwelling": 7049}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 89, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10093257508, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W4 2PD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-06-22 13:31:24.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1, The Copper Vat", "address_line_2": "Lamb Brewery Studios", "address_line_3": "Church Street", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 122, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.87, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 122.4, "quantity": "square metres"}, "party_wall_length": {"value": 26.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 453, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 360, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2293, "space_heating_existing_dwelling": 6750}, "energy_consumption_current": 125, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 47102091, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NE29 6UD", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "NORTH SHIELDS", "built_form": 2, "created_at": "2017-07-11 18:05:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "58, Brahman Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.14, "quantity": "metres"}}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.613, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 310, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 368, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 262, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 60}], "co2_emissions_potential": 2.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 97, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 125, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1832, "space_heating_existing_dwelling": 4121}, "energy_consumption_current": 467, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 369, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 64038095, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF63 4HX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "BARRY", "built_form": 2, "created_at": "2017-08-23 08:28:02.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "355, Holton Road", "assessment_type": "RdSAP", "completion_date": "2017-08-23", "inspection_date": "2017-08-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.85, "quantity": "square metres"}, "party_wall_length": {"value": 11.81, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.31, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 365, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 315, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.7, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2234, "space_heating_existing_dwelling": 4330}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 150, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050672240, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S71 3PR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNSLEY", "built_form": 2, "created_at": "2017-05-12 08:47:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8867}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Wingfield Road", "assessment_type": "RdSAP", "completion_date": "2017-05-12", "inspection_date": "2017-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.23, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 43.04, "quantity": "square metres"}, "party_wall_length": {"value": 7.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 529, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 494, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2838, "space_heating_existing_dwelling": 7214}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 106, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10023506511, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B31 2PB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2017-09-06 16:24:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8643}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, Impey Road", "assessment_type": "RdSAP", "completion_date": "2017-09-06", "inspection_date": "2017-09-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.87, "quantity": "square metres"}, "party_wall_length": {"value": 13.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.87, "quantity": "square metres"}, "party_wall_length": {"value": 13.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 400, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 381, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.2, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2606, "space_heating_existing_dwelling": 5537}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 77, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 90047372, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DY8 3QX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOURBRIDGE", "built_form": 2, "created_at": "2017-08-31 11:55:52.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "73, Park Road", "assessment_type": "RdSAP", "completion_date": "2017-08-31", "inspection_date": "2017-08-30", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.43, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 17.43, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.81, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.97, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 24.97, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.26, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.46, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.51, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 474, "currency": "GBP"}, "insulated_door_count": 2, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 478, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "insulated_door_u_value": 1.6, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2160, "impact_of_loft_insulation": -145, "space_heating_existing_dwelling": 7858}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW18 2DX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-04-03 15:56:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15023}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "36a Killarney Road", "assessment_type": "RdSAP", "completion_date": "2017-04-03", "inspection_date": "2017-04-03", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.23, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-04-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": {"value": 15.9, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.444, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 33.29, "quantity": "square metres"}, "party_wall_length": {"value": 8.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 14.08, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 12.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 706, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 368, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 182, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.0, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1908, "impact_of_loft_insulation": -1007, "impact_of_solid_wall_insulation": -3290, "space_heating_existing_dwelling": 12561}, "energy_consumption_current": 351, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "9.0.0", "energy_consumption_potential": 181, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10024191090, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S1 4DQ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SHEFFIELD", "built_form": 2, "created_at": "2017-05-23 13:58:22.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 32 I Q Steel", "address_line_2": "19, Pitt Street", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.03, "quantity": "metres"}}, "total_floor_area": 21, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.5235, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 20.76, "quantity": "square metres"}, "party_wall_length": {"value": 11.88, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 12.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 231, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 20, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 132, "currency": "GBP"}, "hot_water_cost_current": {"value": 210, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 23, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 234, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 219, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1351, "space_heating_existing_dwelling": 1486}, "energy_consumption_current": 439, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 418, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060938231, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "System built, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DA11 7BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRAVESEND", "built_form": 4, "created_at": "2017-08-14 15:19:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Northcote Road", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-12", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.31, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 24.31, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.59, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.15, "quantity": "metres"}, "total_floor_area": {"value": 5.9, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 8, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.15, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.02, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 89, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1998, "impact_of_loft_insulation": -761, "impact_of_solid_wall_insulation": -1753, "space_heating_existing_dwelling": 8152}, "energy_consumption_current": 242, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 102, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 15074031, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 72% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN4 0TN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 1, "created_at": "2017-06-28 13:20:23", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 8866}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, Wakehurst Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-28", "inspection_date": "2017-06-28", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 206, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2017-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"pv_arrays": [{"pitch": 3, "peak_power": 3.95, "orientation": 5, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.04, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 20.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 61.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 15.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.78, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 72, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1307, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 136, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1258, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 72}], "co2_emissions_potential": 4.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 106, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3007, "impact_of_loft_insulation": -675, "space_heating_existing_dwelling": 19186}, "energy_consumption_current": 150, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 132, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 32, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 23} +{"uprn": 100011478102, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SK5 6SS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 2, "created_at": "2017-04-11 17:26:06.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 5921}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Edale Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.63, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.54, "quantity": "metres"}, "total_floor_area": {"value": 34.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 476, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 388, "currency": "GBP"}, "hot_water_cost_current": {"value": 192, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3099, "space_heating_existing_dwelling": 6292}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 92, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 42121060, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CH47 2DZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIRRAL", "built_form": 4, "created_at": "2017-07-11 14:02:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8827}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "30, Walker Street", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.3, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 33.3, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.98, "quantity": "square metres"}, "party_wall_length": {"value": 1.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 566, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 343, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1996, "impact_of_loft_insulation": -588, "impact_of_solid_wall_insulation": -2813, "space_heating_existing_dwelling": 7687}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 64, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100062561746, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TN25 5EG", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "ASHFORD", "built_form": 4, "created_at": "2017-06-06 16:54:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 9 Gregory Court", "address_line_2": "Churchfield Way", "address_line_3": "Wye", "assessment_type": "RdSAP", "completion_date": "2017-06-06", "inspection_date": "2017-06-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 7.22}, "total_floor_area": 43, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.0392, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 42.59, "quantity": "square metres"}, "party_wall_length": {"value": 7.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 301, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 121, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 127, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1631, "impact_of_loft_insulation": -636, "impact_of_cavity_insulation": -599, "space_heating_existing_dwelling": 3374}, "energy_consumption_current": 390, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 232, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010183518, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CW9 7JE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHWICH", "built_form": 2, "created_at": "2017-06-13 14:09:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8788}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "30, East Avenue", "address_line_2": "Rudheath", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-06-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.73, "quantity": "square metres"}, "party_wall_length": {"value": 5.61, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 41.73, "quantity": "square metres"}, "party_wall_length": {"value": 5.61, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.49, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 844, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 716, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 216, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2613, "impact_of_loft_insulation": -3823, "space_heating_existing_dwelling": 11586}, "energy_consumption_current": 315, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 172, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 33024099, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TW15 1TW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHFORD", "built_form": 3, "created_at": "2017-08-18 06:42:22.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "61, Alexandra Road", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.554, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.20104, "quantity": "square metres"}, "party_wall_length": {"value": 8.293, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.573, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.518, "quantity": "metres"}, "total_floor_area": {"value": 27.20104, "quantity": "square metres"}, "party_wall_length": {"value": 8.293, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.573, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.517, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.79368, "quantity": "square metres"}, "party_wall_length": {"value": 2.689, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.969, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.519, "quantity": "metres"}, "total_floor_area": {"value": 8.79368, "quantity": "square metres"}, "party_wall_length": {"value": 2.689, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.969, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 634, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 398, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1949, "impact_of_solid_wall_insulation": -2177, "space_heating_existing_dwelling": 9425}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 25, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 75, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100061569302, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CR3 5RW", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CATERHAM", "built_form": 2, "created_at": "2017-07-12 18:15:35.000000", "door_count": 4, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17550}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Birch Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.39, "quantity": "square metres"}, "party_wall_length": {"value": 7.28, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 43.39, "quantity": "square metres"}, "party_wall_length": {"value": 7.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 729, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 545, "currency": "GBP"}, "hot_water_cost_current": {"value": 182, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3560, "impact_of_cavity_insulation": -2379, "space_heating_existing_dwelling": 12700}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 122, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200004358, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EN5 5HU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNET", "built_form": 4, "created_at": "2017-09-06 14:48:52.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2039}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Artesian Grove", "assessment_type": "RdSAP", "completion_date": "2017-09-06", "inspection_date": "2017-09-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 302, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.08, "quantity": "square metres"}, "party_wall_length": {"value": 19.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.01, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.08, "quantity": "square metres"}, "party_wall_length": {"value": 23.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 302, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.32, "quantity": "square metres"}, "party_wall_length": {"value": 5.09, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 12.32, "quantity": "square metres"}, "party_wall_length": {"value": 5.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 561, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 107, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2925, "impact_of_loft_insulation": -615, "space_heating_existing_dwelling": 8463}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 78, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 83014237, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HD7 5QX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HUDDERSFIELD", "built_form": 5, "created_at": "2017-06-13 10:44:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Enclosed end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "537, Manchester Road", "address_line_2": "Linthwaite", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-06-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.536, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.273, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.273, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.974, "quantity": "metres"}, "total_floor_area": {"value": 10.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.273, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.273, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.536, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.579, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.974, "quantity": "metres"}, "total_floor_area": {"value": 10.579, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 1114, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 177, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 413, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 95, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 95, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 287, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 337, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1600, "impact_of_solid_wall_insulation": -3047, "space_heating_existing_dwelling": 8168}, "energy_consumption_current": 713, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 241, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 120, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LU1 1HX", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LUTON", "built_form": 5, "created_at": "2017-04-03 15:04:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "35f Crawley Road", "assessment_type": "RdSAP", "completion_date": "2017-04-03", "inspection_date": "2017-04-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 13, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-04-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 13.22, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.2, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 74, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.7, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 15, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 74, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 15, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 127, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 816, "space_heating_existing_dwelling": 479}, "energy_consumption_current": 323, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 323, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "B", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090622156, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CO7 8EB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 1, "created_at": "2017-08-31 10:50:48.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 16773}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Coach Road", "address_line_2": "Alresford", "assessment_type": "RdSAP", "completion_date": "2017-08-31", "inspection_date": "2017-08-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 51.92, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 741, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 117, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 704, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2927, "impact_of_loft_insulation": -4640, "space_heating_existing_dwelling": 13716}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 153, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100023236255, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SE13 7LQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-06-13 19:13:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8441}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "12, Columbine Way", "address_line_2": "Lewisham Road", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-06-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.13, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 44.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.73, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 512, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2181, "impact_of_loft_insulation": -251, "space_heating_existing_dwelling": 7447}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 82, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050206554, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DN15 7QE", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SCUNTHORPE", "built_form": 2, "created_at": "2017-09-28 06:45:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Gervase Street", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.44, "quantity": "square metres"}, "party_wall_length": {"value": 4.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 44.44, "quantity": "square metres"}, "party_wall_length": {"value": 4.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1443, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.1, "energy_rating_average": 60, "energy_rating_current": 32, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 685, "currency": "GBP"}, "hot_water_cost_current": {"value": 320, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 466, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 43}, {"sequence": 5, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 6, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 7, "typical_saving": {"value": 240, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 8, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 9, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 320, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4432, "impact_of_loft_insulation": -3259, "impact_of_solid_wall_insulation": -7870, "space_heating_existing_dwelling": 19439}, "energy_consumption_current": 577, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 173, "environmental_impact_current": 26, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 102, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100040016752, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL12 5EW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SALTASH", "built_form": 2, "created_at": "2017-08-15 10:03:57.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9602}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Home Park", "address_line_2": "Landrake", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 170, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 550, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 447, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2193, "impact_of_solid_wall_insulation": -1272, "space_heating_existing_dwelling": 9515}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.92, "energy_consumption_potential": 85, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 24074654, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS40 7US", "hot_water": {"description": "From main system", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2017-04-28 09:34:24.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 3, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 3, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16417}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "5, Green Lane", "address_line_2": "Butcombe", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 158, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.46, "quantity": "square metres"}, "party_wall_length": {"value": 7.72, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 47.46, "quantity": "square metres"}, "party_wall_length": {"value": 7.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.38, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 31.38, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1405, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1304, "currency": "GBP"}, "hot_water_cost_current": {"value": 354, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.9, "energy_rating_potential": 59, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 207, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2885, "space_heating_existing_dwelling": 11475}, "energy_consumption_current": 137, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 84, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 24} +{"uprn": 766265601, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LU7 0LJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEIGHTON BUZZARD", "built_form": 1, "created_at": "2017-10-02 12:29:58", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15231}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "40, Silver Street", "address_line_2": "Cublington", "assessment_type": "RdSAP", "completion_date": "2017-10-02", "inspection_date": "2017-09-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 170, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-10-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 25}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 55.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.38, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 8, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 28.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 698, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 147, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 599, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3003, "impact_of_loft_insulation": -672, "space_heating_existing_dwelling": 14662}, "energy_consumption_current": 107, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 76, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 27, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100061637599, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "GU21 2SF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOKING", "built_form": 1, "created_at": "2017-08-05 11:37:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 15766}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Hillway", "address_line_2": "Bagshot Road", "address_line_3": "Knaphill", "assessment_type": "RdSAP", "completion_date": "2017-08-05", "inspection_date": "2017-08-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 147, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-08-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.39, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 80.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 678, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 162, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 632, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a3105", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2317, "space_heating_existing_dwelling": 12777}, "energy_consumption_current": 163, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 105, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 202080493, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW10 1JH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-07-27 15:13:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9571}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "5, Kendal Road", "assessment_type": "RdSAP", "completion_date": "2017-07-27", "inspection_date": "2017-07-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 16.54, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.51, "quantity": "square metres"}, "party_wall_length": {"value": 14.94, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 41.51, "quantity": "square metres"}, "party_wall_length": {"value": 14.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 722, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 565, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2277, "impact_of_loft_insulation": -2070, "impact_of_solid_wall_insulation": -2116, "space_heating_existing_dwelling": 11823}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 105, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10004854740, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA14 9BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LLANELLI", "built_form": 2, "created_at": "2017-08-05 20:39:36.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "70, Clos y Gelli", "assessment_type": "RdSAP", "completion_date": "2017-08-05", "inspection_date": "2017-08-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-08-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.75, "quantity": "square metres"}, "party_wall_length": {"value": 6.72, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 31.04, "quantity": "square metres"}, "party_wall_length": {"value": 6.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 388, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 388, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1763, "impact_of_loft_insulation": -144, "space_heating_existing_dwelling": 5802}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 79, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10091005484, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N1 8JU", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2017-05-26 11:18:07.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 950, "water_heating_fuel": 20, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 23", "address_line_2": "40, Danbury Street", "assessment_type": "RdSAP", "completion_date": "2017-05-26", "inspection_date": "2017-05-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 18, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.2, "quantity": "metres"}, "total_floor_area": {"value": 18.2, "quantity": "square metres"}, "party_wall_length": {"value": 12.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 271, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 22, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 134, "currency": "GBP"}, "hot_water_cost_current": {"value": 218, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.5, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 22, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 218, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3689, "impact_of_solid_wall_insulation": -518, "space_heating_existing_dwelling": 3019}, "energy_consumption_current": 686, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 459, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 121, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100061558269, "roofs": [{"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GU15 4HA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBERLEY", "built_form": 4, "created_at": "2017-06-14 13:47:31.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9599}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "134, Upper College Ride", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.38, "quantity": "square metres"}, "party_wall_length": {"value": 18.28, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 47.38, "quantity": "square metres"}, "party_wall_length": {"value": 18.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.37, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 409, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 420, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3062, "space_heating_existing_dwelling": 6264}, "energy_consumption_current": 159, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 76, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090200025, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 77% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE3 7LW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 4, "created_at": "2017-08-25 14:18:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10550}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Holdfield", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.74, "quantity": "square metres"}, "party_wall_length": {"value": 11.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 44.49, "quantity": "square metres"}, "party_wall_length": {"value": 11.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 77, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 622, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 420, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2193, "impact_of_solid_wall_insulation": -3672, "space_heating_existing_dwelling": 10725}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 78, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 22, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 10093048821, "roofs": [{"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE25 6EF", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-09-27 09:14:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "55 High Street", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.5, "quantity": "metres"}}, "total_floor_area": 34, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.75, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 33.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1012, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 23, "lighting_cost_current": {"value": 26, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 191, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 348, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 354, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 188, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.0, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 26, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 214, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 192, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 116, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 900, "impact_of_solid_wall_insulation": -2024, "space_heating_existing_dwelling": 6449}, "energy_consumption_current": 685, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 165, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 116, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10093204893, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "MK40 2SR", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BEDFORD", "built_form": 4, "created_at": "2017-09-01 08:28:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "73 Harpur Street", "assessment_type": "RdSAP", "completion_date": "2017-09-01", "inspection_date": "2017-07-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 5.3}, "total_floor_area": 32, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.402, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 3, "wall_insulation_type": 3, "wall_thickness_measured": "Y", "wall_insulation_thickness": "100mm"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 31.65, "quantity": "square metres"}, "party_wall_length": {"value": 12.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.1, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 333, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 186, "currency": "GBP"}, "hot_water_cost_current": {"value": 223, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 28, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 305, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 286, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 116, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1418, "space_heating_existing_dwelling": 2119}, "energy_consumption_current": 370, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 384, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100022698646, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW11 3TD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-07-31 11:39:04.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16643}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 46 Gardiner House", "address_line_2": "30, Surrey Lane", "assessment_type": "RdSAP", "completion_date": "2017-07-31", "inspection_date": "2017-07-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 6, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 11.75, "quantity": "metres"}}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 27.73, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 46.04, "quantity": "square metres"}, "party_wall_length": {"value": 7.82, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 231, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 206, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 86, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1638, "space_heating_existing_dwelling": 2217}, "energy_consumption_current": 153, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 135, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 303004063, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CO4 0JT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 1, "created_at": "2017-04-06 15:51:11.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "5 Chant Court", "address_line_2": "St. Johns Road", "assessment_type": "RdSAP", "completion_date": "2017-04-06", "inspection_date": "2017-04-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 7.81}, "total_floor_area": 42, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.3535, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.73, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 27.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 455, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 328, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.7, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1681, "impact_of_cavity_insulation": -2219, "space_heating_existing_dwelling": 6677}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 228, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100061439155, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "KT22 9UQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEATHERHEAD", "built_form": 3, "created_at": "2017-04-10 18:17:44.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Warenne Road", "address_line_2": "Fetcham", "assessment_type": "RdSAP", "completion_date": "2017-04-10", "inspection_date": "2017-04-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 14.87, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 12.42, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.39, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.456, "quantity": "metres"}, "total_floor_area": {"value": 27.76, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 759, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 604, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 54}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2171, "impact_of_cavity_insulation": -1984, "space_heating_existing_dwelling": 11430}, "energy_consumption_current": 328, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 159, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 36015502, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LA14 1EH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARROW-IN-FURNESS", "built_form": 4, "created_at": "2017-06-05 16:51:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "16, James Street", "assessment_type": "RdSAP", "completion_date": "2017-06-05", "inspection_date": "2017-05-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.6, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.6, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.8, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 3.8, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 755, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 594, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 40, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 59}}], "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1989, "impact_of_loft_insulation": -2444, "impact_of_cavity_insulation": -1875, "space_heating_existing_dwelling": 12664}, "energy_consumption_current": 342, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "2.11r11", "energy_consumption_potential": 164, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100080875298, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SG1 1NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STEVENAGE", "built_form": 4, "created_at": "2017-06-04 20:14:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16453}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "237, Bedwell Crescent", "assessment_type": "RdSAP", "completion_date": "2017-06-04", "inspection_date": "2017-05-31", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.32, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.76, "quantity": "square metres"}, "party_wall_length": {"value": 13.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.65, "quantity": "metres"}, "total_floor_area": {"value": 40.39, "quantity": "square metres"}, "party_wall_length": {"value": 13.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.05, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 690, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 200, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2604, "impact_of_solid_wall_insulation": -1079, "space_heating_existing_dwelling": 12357}, "energy_consumption_current": 281, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 90046534, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DY8 1HD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOURBRIDGE", "built_form": 2, "created_at": "2017-06-03 10:21:36.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Parkfield Road", "assessment_type": "RdSAP", "completion_date": "2017-06-03", "inspection_date": "2017-06-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 901, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 521, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2125, "impact_of_loft_insulation": -487, "impact_of_solid_wall_insulation": -4922, "space_heating_existing_dwelling": 13359}, "energy_consumption_current": 344, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 123, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10003379977, "roofs": [{"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DY10 1PF", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KIDDERMINSTER", "built_form": 4, "created_at": "2017-09-28 21:54:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 13", "address_line_2": "3 Bromsgrove Street", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 24, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 24.4, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 116, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.7, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 23, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 116, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 23, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1642, "space_heating_existing_dwelling": 474}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 174, "environmental_impact_current": 85, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": null, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B74 4XS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUTTON COLDFIELD", "built_form": 2, "created_at": "2017-10-03 16:19:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "47a Bishops Way", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-09-30", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 19, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.2, "quantity": "square metres"}, "party_wall_length": {"value": 3.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 14.19, "quantity": "square metres"}, "party_wall_length": {"value": 6.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.8, "quantity": "square metres"}, "party_wall_length": {"value": 1.27, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 199, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 201, "currency": "GBP"}, "hot_water_cost_current": {"value": 65, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 83}, {"sequence": 3, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 96, "environmental_impact_rating": 102}], "co2_emissions_potential": -0.1, "energy_rating_potential": 96, "lighting_cost_potential": {"value": 20, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 44, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1396, "space_heating_existing_dwelling": 1848}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": -34, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 102, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100011462979, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SK4 5DU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 1, "created_at": "2017-04-19 08:37:52.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "26, Brooklands Close", "assessment_type": "RdSAP", "completion_date": "2017-04-19", "inspection_date": "2017-04-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 7.75}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.0575, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.52, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 329, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 272, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.5, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1913, "impact_of_cavity_insulation": -283, "space_heating_existing_dwelling": 4578}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 179, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 83002920, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HD7 5DW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 2, "created_at": "2017-04-18 21:09:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17013}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Longlands Avenue", "address_line_2": "Slaithwaite", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-13", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 56, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 945, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 523, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 384, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2057, "impact_of_solid_wall_insulation": -8219, "space_heating_existing_dwelling": 17738}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 113, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100040222356, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "EX2 7BG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EXETER", "built_form": 2, "created_at": "2017-06-08 10:57:10.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "104, Lower Wear Road", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-06-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 2, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.25, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.25, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 709, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 679, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2020, "impact_of_loft_insulation": -516, "impact_of_cavity_insulation": -473, "space_heating_existing_dwelling": 12641}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 140, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100011682751, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "M33 2RD", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SALE", "built_form": 2, "created_at": "2017-06-09 09:25:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Boundary Grove", "assessment_type": "RdSAP", "completion_date": "2017-06-09", "inspection_date": "2017-06-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 8.37, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 8.31, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.56, "quantity": "square metres"}, "party_wall_length": {"value": 7.13, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 43.56, "quantity": "square metres"}, "party_wall_length": {"value": 7.13, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.35, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 910, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 664, "currency": "GBP"}, "hot_water_cost_current": {"value": 232, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 6, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 7, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 8, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 9, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 201, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3575, "impact_of_loft_insulation": -3630, "space_heating_existing_dwelling": 13169}, "energy_consumption_current": 337, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 155, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090203120, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE1 3RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 1, "created_at": "2017-09-01 18:37:38.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16835}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Lawn Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-01", "inspection_date": "2017-08-30", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 43.65, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 549, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 501, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2870, "impact_of_loft_insulation": -172, "space_heating_existing_dwelling": 9566}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 766253942, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HP19 7XG", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AYLESBURY", "built_form": 4, "created_at": "2017-07-21 12:27:29.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "12 Enid Blyton House", "address_line_2": "Wycliffe End", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-07-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 26, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 26.39, "quantity": "square metres"}, "party_wall_length": {"value": 14.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.63, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 173, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 22, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 173, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 22, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1654, "impact_of_loft_insulation": -728, "space_heating_existing_dwelling": 1449}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 228, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10010441070, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "N7 8HD", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-04-20 17:25:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 17 Charrington Court", "address_line_2": "83-91, Georges Road", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.26, "quantity": "metres"}}, "total_floor_area": 15, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.276, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 400, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 15.38, "quantity": "square metres"}, "party_wall_length": {"value": 3.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 262, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 33, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 50, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 82}], "co2_emissions_potential": 0.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 18, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 140, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 817, "impact_of_solid_wall_insulation": -1113, "space_heating_existing_dwelling": 1880}, "energy_consumption_current": 580, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 286, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 2, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 98, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100030431313, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LE12 9LA", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LOUGHBOROUGH", "built_form": 1, "created_at": "2017-06-14 15:58:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8962}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Anson Road", "address_line_2": "Shepshed", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 41.41, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.47, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 32.54, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.53, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 958, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 126, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 810, "currency": "GBP"}, "hot_water_cost_current": {"value": 221, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 263, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3656, "space_heating_existing_dwelling": 12653}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 131, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 38028721, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L8 0SW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2017-08-08 19:14:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17503}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Cedar Grove", "address_line_2": "Toxteth", "assessment_type": "RdSAP", "completion_date": "2017-08-08", "inspection_date": "2017-08-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.31, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 30.53, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.75, "quantity": "square metres"}, "party_wall_length": {"value": 2.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 5.75, "quantity": "square metres"}, "party_wall_length": {"value": 2.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 540, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 427, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1848, "impact_of_loft_insulation": -484, "impact_of_solid_wall_insulation": -2402, "space_heating_existing_dwelling": 8900}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 310040816, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG1 3LS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 4, "created_at": "2017-04-18 08:41:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10565}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, School Terrace", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-06", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 9, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.93, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.63, "quantity": "square metres"}, "party_wall_length": {"value": 8.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 15.63, "quantity": "square metres"}, "party_wall_length": {"value": 8.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.57, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 15.63, "quantity": "square metres"}, "party_wall_length": {"value": 8.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.91, "quantity": "square metres"}, "party_wall_length": {"value": 4.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.46, "quantity": "square metres"}, "party_wall_length": {"value": 5.86, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 10.46, "quantity": "square metres"}, "party_wall_length": {"value": 5.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 634, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2067, "impact_of_loft_insulation": -2163, "impact_of_solid_wall_insulation": -2735, "space_heating_existing_dwelling": 10050}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 110, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 21031750, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HU5 5ES", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 3, "created_at": "2017-04-28 15:30:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8643}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "57, Dunston Road", "assessment_type": "RdSAP", "completion_date": "2017-04-28", "inspection_date": "2017-04-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 35.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 508, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 419, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2590, "impact_of_loft_insulation": -399, "space_heating_existing_dwelling": 7420}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 93, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10002307189, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG22 8UR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWARK", "built_form": 1, "created_at": "2017-06-16 21:35:58.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9897}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Cremorne Drive", "address_line_2": "Bilsthorpe", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 30.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 53.9, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 654, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 624, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2943, "space_heating_existing_dwelling": 9339}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 115, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100023154583, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N15 6UE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-06-19 17:29:03.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "30, Ferndale Road", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-19", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.95, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.54, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 546, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 347, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.9, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2150, "impact_of_cavity_insulation": -316, "impact_of_solid_wall_insulation": -3406, "space_heating_existing_dwelling": 9224}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 182, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100110281974, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CA3 9PX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARLISLE", "built_form": 5, "created_at": "2017-04-07 16:03:45.000000", "door_count": 1, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8362}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Enclosed End-Terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31, Gleneagles Drive", "assessment_type": "RdSAP", "completion_date": "2017-04-07", "inspection_date": "2017-04-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 40, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-04-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 20, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 314, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.5, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 49, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1546, "impact_of_loft_insulation": -146, "space_heating_existing_dwelling": 4234}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 61, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010737402, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 11% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BB1 8RE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKBURN", "built_form": 1, "created_at": "2017-05-04 16:24:53.000000", "door_count": 3, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Cranshaw Drive", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-05-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 325, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.42, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 39.42, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 325, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.89, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 679, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 613, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 125, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2235, "space_heating_existing_dwelling": 10703}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r10", "energy_consumption_potential": 136, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 28, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 24025060, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BS22 8AX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WESTON-SUPER-MARE", "built_form": 4, "created_at": "2017-06-23 16:36:31.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "23, Bailey Close", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.52, "quantity": "square metres"}, "party_wall_length": {"value": 12.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 29.52, "quantity": "square metres"}, "party_wall_length": {"value": 12.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 388, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 377, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2606, "impact_of_loft_insulation": -437, "space_heating_existing_dwelling": 5890}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 86, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 72049260, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LS11 0HQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 4, "created_at": "2017-10-25 11:31:11.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17741}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "68, Cottingley Approach", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.64, "quantity": "square metres"}, "party_wall_length": {"value": 16.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 38.64, "quantity": "square metres"}, "party_wall_length": {"value": 16.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 459, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 441, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1913, "impact_of_loft_insulation": -944, "space_heating_existing_dwelling": 6998}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 100, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060013309, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN22 8EH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EASTBOURNE", "built_form": 4, "created_at": "2017-07-04 16:23:04.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "30, Manifold Road", "assessment_type": "RdSAP", "completion_date": "2017-07-04", "inspection_date": "2017-07-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.18, "quantity": "square metres"}, "party_wall_length": {"value": 16.02, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 43.16, "quantity": "square metres"}, "party_wall_length": {"value": 16.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.81, "quantity": "square metres"}, "party_wall_length": {"value": 1.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 653, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 516, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2347, "impact_of_loft_insulation": -1251, "impact_of_cavity_insulation": -2606, "space_heating_existing_dwelling": 11815}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 101, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100080967439, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "AL10 0RR", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HATFIELD", "built_form": 3, "created_at": "2017-07-03 12:30:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "68, Walsingham Close", "assessment_type": "RdSAP", "completion_date": "2017-07-03", "inspection_date": "2017-07-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 56, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 340, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 56.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 431, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 188, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 282, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 248, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 151, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1754, "space_heating_existing_dwelling": 3063}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 231, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100070062939, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY9 5AW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BISHOPS CASTLE", "built_form": 2, "created_at": "2017-05-15 09:28:24", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 3, "main_heating_number": 1, "main_heating_control": 2207, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "true", "main_heating_data_source": 1, "main_heating_index_number": 100052}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, radiators, electric", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "1, Grange Road", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 37, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.69, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 291, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 208, "currency": "GBP"}, "hot_water_cost_current": {"value": 301, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 198, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2252, "space_heating_existing_dwelling": 5746}, "energy_consumption_current": 331, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100061081270, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME12 3SD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEERNESS", "built_form": 1, "created_at": "2017-07-03 06:16:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10032}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Saxon House", "address_line_2": "Scocles Road", "address_line_3": "Minster on Sea", "assessment_type": "RdSAP", "completion_date": "2017-07-03", "inspection_date": "2017-06-30", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 201, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-07-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 95.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 41.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 95.9, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 883, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 753, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 116, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2347, "space_heating_existing_dwelling": 15742}, "energy_consumption_current": 144, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100110723785, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE20 0JD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 1, "created_at": "2017-08-25 14:47:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15224}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Little Brampton", "address_line_2": "The Avenue", "address_line_3": "Medburn", "assessment_type": "RdSAP", "completion_date": "2017-08-25", "inspection_date": "2017-08-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 956, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 547, "currency": "GBP"}, "hot_water_cost_current": {"value": 199, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 227, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 7, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 9, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}, {"sequence": 10, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 96, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.4, "energy_rating_potential": 96, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 50}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4185, "impact_of_loft_insulation": -473, "impact_of_cavity_insulation": -4012, "space_heating_existing_dwelling": 16320}, "energy_consumption_current": 328, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 12, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10008299676, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "N1 4BD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-08-30 17:53:15.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3 Frederick Building", "address_line_2": "76, Tottenham Road", "assessment_type": "RdSAP", "completion_date": "2017-08-30", "inspection_date": "2017-08-30", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 11.8, "quantity": "metres"}}, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 33.394, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 100.03, "quantity": "square metres"}, "party_wall_length": {"value": 13.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 713, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 144, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 374, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a395", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 96, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2274, "impact_of_solid_wall_insulation": -2674, "space_heating_existing_dwelling": 10786}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 115, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061383779, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU4 7LP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GUILDFORD", "built_form": 2, "created_at": "2017-08-29 12:50:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16673}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "54, Burpham Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 128, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.65, "quantity": "square metres"}, "party_wall_length": {"value": 12.77, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 48.65, "quantity": "square metres"}, "party_wall_length": {"value": 12.77, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.34, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 15.11, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 15.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 728, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 174, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2974, "impact_of_solid_wall_insulation": -3835, "space_heating_existing_dwelling": 13460}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100022188613, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "IG7 4NB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHIGWELL", "built_form": 2, "created_at": "2017-09-04 11:41:25.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9461}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Bearing Way", "assessment_type": "RdSAP", "completion_date": "2017-09-04", "inspection_date": "2017-09-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 730, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 705, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.5, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2823, "impact_of_loft_insulation": -207, "space_heating_existing_dwelling": 10815}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 173, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 310050109, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG4 8QA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 4, "created_at": "2017-04-10 15:40:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8575}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6 Springfield Mews", "address_line_2": "Surley Row", "address_line_3": "Emmer Green", "assessment_type": "RdSAP", "completion_date": "2017-04-10", "inspection_date": "2017-04-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "registration_date": "2017-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 26.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 35.42, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 20.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.84, "quantity": "square metres"}, "party_wall_length": {"value": 4.11, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 621, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 525, "currency": "GBP"}, "hot_water_cost_current": {"value": 148, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2614, "space_heating_existing_dwelling": 8665}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100031464747, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 47% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG14 7GE", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2017-05-15 20:41:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4035}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "22, Manor Close", "address_line_2": "Bleasby", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, coal", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 83.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 39.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 47, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 696, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 506, "currency": "GBP"}, "hot_water_cost_current": {"value": 204, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 7, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 148, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3321, "space_heating_existing_dwelling": 8931}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 110, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100020401626, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BR1 4SB", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BROMLEY", "built_form": 4, "created_at": "2017-05-15 10:51:03.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "12, Hillcrest Road", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.13, "quantity": "square metres"}, "party_wall_length": {"value": 12.65, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 33.29, "quantity": "square metres"}, "party_wall_length": {"value": 13.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1350, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 18, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 576, "currency": "GBP"}, "hot_water_cost_current": {"value": 370, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 27, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 573, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 39}, {"sequence": 6, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 42}, {"sequence": 7, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 51}], "co2_emissions_potential": 3.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 662, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 655, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2381, "impact_of_loft_insulation": -2183, "impact_of_solid_wall_insulation": -2223, "space_heating_existing_dwelling": 8685}, "energy_consumption_current": 543, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 301, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "G", "environmental_impact_potential": 51, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 92, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100022216083, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "IG3 9YB", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ILFORD", "built_form": 4, "created_at": "2017-05-11 19:35:11.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 601, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Guildford Road", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.3, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 34.3, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1143, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6, "energy_rating_average": 60, "energy_rating_current": 31, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 503, "currency": "GBP"}, "hot_water_cost_current": {"value": 190, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 219, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 421, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 368, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 365, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 495, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1221, "impact_of_loft_insulation": -2770, "impact_of_solid_wall_insulation": -2596, "space_heating_existing_dwelling": 11553}, "energy_consumption_current": 498, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "1.0.x", "energy_consumption_potential": 111, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "F", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 87, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10023984751, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG5 2HL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2017-09-08 16:05:13.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7 Ryan Court", "address_line_2": "Crossman Street", "assessment_type": "RdSAP", "completion_date": "2017-09-08", "inspection_date": "2017-09-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 22.04, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "K", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.64, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.64, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 387, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 387, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2122, "space_heating_existing_dwelling": 4791}, "energy_consumption_current": 150, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 72, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100060470241, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BH23 8NR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHRISTCHURCH", "built_form": 3, "created_at": "2017-07-13 15:45:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "77, Rosehill Drive", "address_line_2": "Bransgore", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 398, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 301, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.4, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1846, "impact_of_cavity_insulation": -1406, "space_heating_existing_dwelling": 6194}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 43, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100051292155, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD18 1JY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHIPLEY", "built_form": 2, "created_at": "2017-07-13 13:15:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16212}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Thornacre Road", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.54, "quantity": "square metres"}, "party_wall_length": {"value": 6.68, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 31.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.25, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 679, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1989, "impact_of_loft_insulation": -631, "impact_of_cavity_insulation": -3694, "space_heating_existing_dwelling": 12068}, "energy_consumption_current": 308, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 131, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10003185262, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB22 7SH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "CAMBRIDGE", "built_form": 2, "created_at": "2017-05-05 14:25:03.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Primes Close", "address_line_2": "Barrington", "assessment_type": "RdSAP", "completion_date": "2017-05-05", "inspection_date": "2017-03-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-05-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 345, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 645, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 363, "currency": "GBP"}, "hot_water_cost_current": {"value": 216, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 44}, {"sequence": 3, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 280, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 228, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 255, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2461, "impact_of_loft_insulation": -737, "space_heating_existing_dwelling": 7341}, "energy_consumption_current": 428, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 73, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200003864107, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TN38 9DS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. LEONARDS-ON-SEA", "built_form": 3, "created_at": "2017-08-14 14:15:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "253, Hollington Old Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.42, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48.38, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 847, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 498, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 10, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 204, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2227, "impact_of_cavity_insulation": -4058, "space_heating_existing_dwelling": 14512}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "2.12r11", "energy_consumption_potential": 94, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100022207659, "roofs": [{"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG5 0QF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 2, "created_at": "2017-07-17 20:04:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10093}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "true"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "66, Dovedale Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-17", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 173, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 27.14, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.87, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 42.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.87, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.37, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 6.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 13.44, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 731, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 637, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 147, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3084, "impact_of_loft_insulation": -1390, "impact_of_cavity_insulation": -1225, "space_heating_existing_dwelling": 12667}, "energy_consumption_current": 144, "has_fixed_air_conditioning": "true", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["O"], "calculation_software_version": "2.11r11", "energy_consumption_potential": 96, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 45, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 45} +{"uprn": 202216491, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NW2 7ER", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2017-05-24 18:39:24.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "6a, Coles Green Road", "assessment_type": "RdSAP", "completion_date": "2017-05-24", "inspection_date": "2017-05-23", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 570, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 370, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1838, "impact_of_solid_wall_insulation": -3338, "space_heating_existing_dwelling": 9734}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 143, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100030584129, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE2 5WF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 1, "created_at": "2017-06-23 18:08:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16919}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "9, Frensham Close", "address_line_2": "Oadby", "assessment_type": "RdSAP", "completion_date": "2017-06-23", "inspection_date": "2017-06-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.6, "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78.31, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.26, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.13, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.59, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 751, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 564, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2113, "impact_of_cavity_insulation": -261, "space_heating_existing_dwelling": 13564}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 110, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100011521358, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SK7 3AH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 1, "created_at": "2017-09-29 14:25:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17558}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "8, Southern Crescent", "address_line_2": "Bramhall", "assessment_type": "RdSAP", "completion_date": "2017-09-29", "inspection_date": "2017-09-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 130, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 64.38, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1103, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 676, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2126, "impact_of_loft_insulation": -841, "impact_of_cavity_insulation": -7148, "space_heating_existing_dwelling": 21697}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 81, "calculation_software_version": "2.13r09", "energy_consumption_potential": 127, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100030137162, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DE7 6EZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ILKESTON", "built_form": 1, "created_at": "2017-06-07 07:53:38.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8061}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Glenfield", "address_line_2": "Morley Lane", "address_line_3": "Stanley", "assessment_type": "RdSAP", "completion_date": "2017-06-07", "inspection_date": "2017-06-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 68.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 659, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 303, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 78}, {"sequence": 8, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 109, "environmental_impact_rating": 100}], "co2_emissions_potential": -0.1, "energy_rating_potential": 109, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2709, "impact_of_solid_wall_insulation": -5010, "space_heating_existing_dwelling": 11949}, "energy_consumption_current": 330, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": -83, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 100, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100100060658, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF24 4GE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2017-07-15 00:33:59.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10552}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Pen-y-Wain Road", "assessment_type": "RdSAP", "completion_date": "2017-07-15", "inspection_date": "2017-07-14", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 152, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-07-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 28.27, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.06, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 37.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.18, "quantity": "square metres"}, "party_wall_length": {"value": 6.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.54, "quantity": "metres"}, "total_floor_area": {"value": 21.18, "quantity": "square metres"}, "party_wall_length": {"value": 6.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.94, "quantity": "square metres"}, "party_wall_length": {"value": 1.29, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.49, "quantity": "square metres"}, "party_wall_length": {"value": 1.93, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1260, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 792, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 208, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2320, "impact_of_loft_insulation": -2398, "impact_of_solid_wall_insulation": -4229, "space_heating_existing_dwelling": 24281}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 131, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 20, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 15018179, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN3 6PQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 4, "created_at": "2017-09-14 17:20:55", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Lakeview Green", "assessment_type": "RdSAP", "completion_date": "2017-09-14", "inspection_date": "2017-09-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 100}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.15, "quantity": "square metres"}, "party_wall_length": {"value": 10.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.15, "quantity": "square metres"}, "party_wall_length": {"value": 10.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 515, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.7, "energy_rating_average": 60, "energy_rating_current": 95, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 489, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 96, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 98, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.4, "energy_rating_potential": 98, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2094, "space_heating_existing_dwelling": 8774}, "energy_consumption_current": 45, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 21, "environmental_impact_current": 90, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "A", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 9, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10000275946, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Granite or whinstone, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX14 9JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HONITON", "built_form": 1, "created_at": "2017-08-13 18:39:17", "door_count": 4, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 127, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Widworthy Mill", "address_line_2": "Wilmington", "assessment_type": "RdSAP", "completion_date": "2017-08-13", "inspection_date": "2017-08-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 213, "transaction_type": 11, "conservatory_type": 2, "heated_room_count": 9, "pvc_window_frames": "false", "registration_date": "2017-08-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 62, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "300mm"}, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.13, "quantity": "metres"}, "total_floor_area": {"value": 71.5, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1188, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.1, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 815, "currency": "GBP"}, "hot_water_cost_current": {"value": 148, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 79}], "co2_emissions_potential": 3.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 100, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3010, "impact_of_loft_insulation": -853, "space_heating_existing_dwelling": 23337}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 45, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 2465159581, "roofs": [{"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 27% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LE3 0BG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-07-26 23:08:24.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "14a, Upperton Road", "assessment_type": "RdSAP", "completion_date": "2017-07-26", "inspection_date": "2017-07-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 168, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-07-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": 78.08, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.91, "quantity": "metres"}, "total_floor_area": {"value": 89.94, "quantity": "square metres"}, "party_wall_length": {"value": 10.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1738, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.7, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 159, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 744, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 578, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "co2_emissions_potential": 4.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 94, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2264, "impact_of_loft_insulation": -848, "impact_of_solid_wall_insulation": -4519, "space_heating_existing_dwelling": 35583}, "energy_consumption_current": 327, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.11r11", "energy_consumption_potential": 144, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 45117988, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR5 5HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 1, "created_at": "2017-06-02 08:36:27.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "22, Rishton Square", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-05-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 8.6}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.0, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 408, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 308, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.5, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1530, "impact_of_cavity_insulation": -510, "space_heating_existing_dwelling": 5073}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 201, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100031556354, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG5 9NB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2017-06-20 17:58:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "9, Helmsdale Gardens", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-04-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.4, "quantity": "square metres"}, "party_wall_length": {"value": 13.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 292, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 259, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1707, "impact_of_loft_insulation": -393, "space_heating_existing_dwelling": 2909}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 153, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100046935, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM9 6AH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAGENHAM", "built_form": 4, "created_at": "2017-08-26 09:48:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, Polesworth Road", "assessment_type": "RdSAP", "completion_date": "2017-08-26", "inspection_date": "2017-08-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 32.5, "quantity": "square metres"}, "party_wall_length": {"value": 13.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 477, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 314, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1777, "impact_of_loft_insulation": -176, "impact_of_solid_wall_insulation": -2598, "space_heating_existing_dwelling": 7940}, "energy_consumption_current": 245, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 53, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100032003133, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE14 1TD", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BURTON-ON-TRENT", "built_form": 2, "created_at": "2017-09-28 16:59:11.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat B Trent Bridge House", "address_line_2": "14, Meadow Road", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 7.0}, "total_floor_area": 30, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 480, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 188, "currency": "GBP"}, "hot_water_cost_current": {"value": 309, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 197, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 176, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2307, "impact_of_solid_wall_insulation": -3603, "space_heating_existing_dwelling": 6908}, "energy_consumption_current": 959, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 405, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 162, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 3455153730, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST4 5AN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2017-04-06 12:50:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat A", "address_line_2": "375 London Road", "assessment_type": "RdSAP", "completion_date": "2017-04-06", "inspection_date": "2017-04-06", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.4, "quantity": "metres"}}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.02, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.84, "quantity": "square metres"}, "party_wall_length": {"value": 10.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.18, "quantity": "square metres"}, "party_wall_length": {"value": 5.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.46, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 515, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 375, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.9, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1541, "impact_of_loft_insulation": -863, "impact_of_cavity_insulation": -618, "impact_of_solid_wall_insulation": -1337, "space_heating_existing_dwelling": 8611}, "energy_consumption_current": 375, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 272, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 63140198, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WF3 4ND", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WAKEFIELD", "built_form": 1, "created_at": "2017-05-07 23:28:58.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 2040}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Clarke Hall Road", "address_line_2": "Stanley", "assessment_type": "RdSAP", "completion_date": "2017-05-07", "inspection_date": "2017-05-06", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 130, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-05-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 57.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 935, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 173, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 876, "currency": "GBP"}, "hot_water_cost_current": {"value": 230, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3200", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 87, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 95, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 325, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4023, "impact_of_loft_insulation": -379, "space_heating_existing_dwelling": 12268}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 141, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 40, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 33028476, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TW19 7NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "STAINES-UPON-THAMES", "built_form": 2, "created_at": "2017-07-06 18:18:02.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "87, Park Road", "address_line_2": "Stanwell", "assessment_type": "RdSAP", "completion_date": "2017-07-06", "inspection_date": "2017-07-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70, "quantity": "square metres"}, "party_wall_length": {"value": 8.51, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.29, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 391, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 270, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 164, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2575, "space_heating_existing_dwelling": 4335}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 134, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100006663, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM9 5UT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAGENHAM", "built_form": 4, "created_at": "2017-09-06 18:40:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "97, Connor Road", "assessment_type": "RdSAP", "completion_date": "2017-09-06", "inspection_date": "2017-09-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.5, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 38.5, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 601, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 353, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2081, "impact_of_loft_insulation": -743, "impact_of_solid_wall_insulation": -2613, "space_heating_existing_dwelling": 8909}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 64, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100080129212, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LU4 0SR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LUTON", "built_form": 3, "created_at": "2017-09-06 20:30:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 109, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Binder Close", "assessment_type": "RdSAP", "completion_date": "2017-09-06", "inspection_date": "2017-09-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.81, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 40.81, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 674, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 413, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a380", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 158, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2672, "space_heating_existing_dwelling": 8341}, "energy_consumption_current": 308, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100020445072, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE26 5HX", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-06-06 23:55:47.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 33 Servite House", "address_line_2": "171, Venner Road", "assessment_type": "RdSAP", "completion_date": "2017-06-06", "inspection_date": "2017-06-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 32, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 32.05, "quantity": "square metres"}, "party_wall_length": {"value": 10.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 180, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 25, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 180, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 25, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1767, "impact_of_loft_insulation": -205, "space_heating_existing_dwelling": 1485}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 198, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100010550754, "roofs": [{"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 12% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PR2 8PE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRESTON", "built_form": 1, "created_at": "2017-05-11 16:21:23.000000", "door_count": 3, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15701}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, Higher Bank Road", "address_line_2": "Fulwood", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 143, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, coal", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 44.59, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 29.55, "wall_dry_lined": "N", "wall_thickness": 340, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 44.59, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 3.74, "wall_dry_lined": "N", "wall_thickness": 340, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 12, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2328, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 15, "energy_rating_average": 60, "energy_rating_current": 31, "lighting_cost_current": {"value": 146, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1399, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 353, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 25}, {"sequence": 2, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 27}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 28}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 30}, {"sequence": 5, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 30}, {"sequence": 6, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 36}, {"sequence": 7, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 39}, {"sequence": 8, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 43}], "co2_emissions_potential": 8.0, "energy_rating_potential": 62, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 42, "environmental_impact_rating": 28}}], "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2314, "impact_of_loft_insulation": -828, "impact_of_cavity_insulation": -6020, "impact_of_solid_wall_insulation": -2219, "space_heating_existing_dwelling": 38400}, "energy_consumption_current": 479, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 252, "environmental_impact_current": 18, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 43, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 103, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 6041498, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E2 9JZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-09-06 18:29:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 11 Chesil Court", "address_line_2": "Bonner Road", "assessment_type": "RdSAP", "completion_date": "2017-09-06", "inspection_date": "2017-09-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.9, "quantity": "metres"}}, "total_floor_area": 48, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.456, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 47.61, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 149, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 130, "currency": "GBP"}, "hot_water_cost_current": {"value": 155, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 133, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1967, "space_heating_existing_dwelling": 1609}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 220, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 38011305, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L6 1JL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 1, "created_at": "2017-10-06 12:34:02.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10321}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "7, Baker Way", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 521, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}, {"sequence": 5, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 110, "environmental_impact_rating": 108}], "co2_emissions_potential": -0.8, "energy_rating_potential": 110, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2429, "impact_of_loft_insulation": -882, "space_heating_existing_dwelling": 7166}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": -83, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 108, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100050183092, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN18 5ET", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARTON-UPON-HUMBER", "built_form": 4, "created_at": "2017-04-06 21:28:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Priestgate", "assessment_type": "RdSAP", "completion_date": "2017-04-06", "inspection_date": "2017-04-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.25, "quantity": "square metres"}, "party_wall_length": {"value": 9.87, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 38.25, "quantity": "square metres"}, "party_wall_length": {"value": 15.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 888, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 341, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 7, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.8, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2076, "impact_of_solid_wall_insulation": -4671, "space_heating_existing_dwelling": 12154}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 59, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 32127476, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B67 6PS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SMETHWICK", "built_form": 4, "created_at": "2017-10-09 16:00:45.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10068}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "32, Awefields Crescent", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.54, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.38, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 282, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 255, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1661, "space_heating_existing_dwelling": 3643}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 163, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10093494708, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE1 2TZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PETERBOROUGH", "built_form": 5, "created_at": "2017-10-10 12:41:47.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "117, Park Road", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 12.1, "quantity": "metres"}}, "total_floor_area": 36, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 29.04, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.4, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 410, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 186, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 160, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 200, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 181, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 120, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1663, "space_heating_existing_dwelling": 2916}, "energy_consumption_current": 402, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 340, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 77055141, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "M22 1AE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 3, "created_at": "2017-10-09 12:08:03.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Summerfield Road", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.06, "quantity": "square metres"}, "party_wall_length": {"value": 6.23, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 37.06, "quantity": "square metres"}, "party_wall_length": {"value": 6.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.23, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 493, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 457, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2050, "space_heating_existing_dwelling": 6656}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 102, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100080953787, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WD17 1QS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WATFORD", "built_form": 4, "created_at": "2017-05-10 00:38:03.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9205}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Westland Road", "assessment_type": "RdSAP", "completion_date": "2017-05-09", "inspection_date": "2017-05-02", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 155, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-05-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 390, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 18.53, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "C"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.64, "quantity": "square metres"}, "party_wall_length": {"value": 22.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 62.64, "quantity": "square metres"}, "party_wall_length": {"value": 22.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.58, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.94, "quantity": "square metres"}, "party_wall_length": 1.9, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1515, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.5, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 878, "currency": "GBP"}, "hot_water_cost_current": {"value": 176, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 241, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 249, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 192, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3163, "impact_of_loft_insulation": -3921, "impact_of_solid_wall_insulation": -4628, "space_heating_existing_dwelling": 26463}, "energy_consumption_current": 308, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 135, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100080966513, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "AL10 8JX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HATFIELD", "built_form": 4, "created_at": "2017-06-21 06:51:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8407}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "32, The Downs", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.24, "quantity": "square metres"}, "party_wall_length": {"value": 5.41, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 37.24, "quantity": "square metres"}, "party_wall_length": {"value": 10.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 484, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 395, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2762, "impact_of_loft_insulation": -251, "space_heating_existing_dwelling": 6952}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 81, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100062110584, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN4 8DN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "TUNBRIDGE WELLS", "built_form": 4, "created_at": "2017-04-15 09:47:17.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "12, Molyneux Park Road", "assessment_type": "RdSAP", "completion_date": "2017-04-15", "inspection_date": "2017-04-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.69, "quantity": "metres"}}, "total_floor_area": 41, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-04-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.225, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 40.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 563, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 141, "currency": "GBP"}, "hot_water_cost_current": {"value": 190, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 343, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 165, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 152, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1720, "impact_of_solid_wall_insulation": -2520, "space_heating_existing_dwelling": 4103}, "energy_consumption_current": 461, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 268, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200000314623, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA1 2EX", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "HARROW", "built_form": 4, "created_at": "2017-06-14 16:05:57.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 515, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Warm air, Electricaire", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "324 Platinum House", "address_line_2": "Lyon Road", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 9.78}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 46.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 309, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 264, "currency": "GBP"}, "hot_water_cost_current": {"value": 260, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.8, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 228, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1674, "space_heating_existing_dwelling": 1924}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 227, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100090444519, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CO2 8DL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 2, "created_at": "2017-08-03 12:32:44.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "35a, Cheveling Road", "assessment_type": "RdSAP", "completion_date": "2017-08-03", "inspection_date": "2017-08-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-08-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.81, "quantity": "square metres"}, "party_wall_length": {"value": 10.79, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.49, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 296, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 255, "currency": "GBP"}, "hot_water_cost_current": {"value": 69, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1494, "space_heating_existing_dwelling": 4004}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 188, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100010751587, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 12% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BB2 1SP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKBURN", "built_form": 4, "created_at": "2017-04-03 16:34:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15710}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "4, Oakenhurst Road", "assessment_type": "RdSAP", "completion_date": "2017-04-03", "inspection_date": "2017-04-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.75, "quantity": "metres"}}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.98, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.432, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.202, "quantity": "square metres"}, "party_wall_length": {"value": 7.523, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.863, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 12, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 367, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 291, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1847, "impact_of_solid_wall_insulation": -524, "space_heating_existing_dwelling": 5328}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 152, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100090090017, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE19 5RD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ST. NEOTS", "built_form": 2, "created_at": "2017-08-03 17:36:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "10, Blenheim Grove", "address_line_2": "Offord D'Arcy", "assessment_type": "RdSAP", "completion_date": "2017-08-03", "inspection_date": "2017-08-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 617, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 385, "currency": "GBP"}, "hot_water_cost_current": {"value": 236, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 115, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3421, "space_heating_existing_dwelling": 6557}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 79, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100061607119, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU9 0QL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FARNHAM", "built_form": 2, "created_at": "2017-10-03 19:30:05.000000", "door_count": 2, "glazed_area": 4, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9970}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "true", "glazing_gap": 12, "orientation": 4, "window_area": {"value": 8.99, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0, "window_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 2, "window_area": {"value": 2.19, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0, "window_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 8, "window_area": {"value": 7.26, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0, "window_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 4, "window_area": {"value": 0.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 2, "window_area": {"value": 0.61, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 8, "window_area": {"value": 0.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Poplar Walk", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-10-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.15, "quantity": "square metres"}, "party_wall_length": {"value": 7.54, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 38.15, "quantity": "square metres"}, "party_wall_length": {"value": 7.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.66, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.84, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 577, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 470, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2815, "impact_of_loft_insulation": -400, "space_heating_existing_dwelling": 7499}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100050082898, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HU11 5SS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 3, "created_at": "2017-07-04 07:15:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17923}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, LPG", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1-2, Lawrence Avenue", "address_line_2": "Catfoss", "assessment_type": "RdSAP", "completion_date": "2017-07-04", "inspection_date": "2017-07-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 163, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 18.5, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "D", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 67.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2282, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.2, "energy_rating_average": 60, "energy_rating_current": 26, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1708, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 515, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 62}], "co2_emissions_potential": 5.7, "energy_rating_potential": 48, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2327, "impact_of_loft_insulation": -1189, "impact_of_solid_wall_insulation": -6935, "space_heating_existing_dwelling": 29023}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 154, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 41077531, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L23 9TB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 3, "created_at": "2017-10-03 20:34:22.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Redgate Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-10-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 437, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2117, "space_heating_existing_dwelling": 7835}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 86, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100120550649, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GL20 8QW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TEWKESBURY", "built_form": 3, "created_at": "2017-05-03 16:13:07.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Oak Drive", "assessment_type": "RdSAP", "completion_date": "2017-05-03", "inspection_date": "2017-05-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.52, "quantity": "square metres"}, "party_wall_length": {"value": 7.27, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 33.52, "quantity": "square metres"}, "party_wall_length": {"value": 7.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.49, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 408, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1963, "impact_of_loft_insulation": -343, "space_heating_existing_dwelling": 6377}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10000202198, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU6 7FE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HULL", "built_form": 1, "created_at": "2017-05-04 09:37:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, St. Anthony's Close", "assessment_type": "RdSAP", "completion_date": "2017-05-04", "inspection_date": "2017-05-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 38.4, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 25.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.86, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 549, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 451, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2785, "impact_of_loft_insulation": -249, "space_heating_existing_dwelling": 7261}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 98, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 50026347, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT20 3BT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FOLKESTONE", "built_form": 2, "created_at": "2017-07-03 13:27:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "21, Valley Road", "address_line_2": "Sandgate", "assessment_type": "RdSAP", "completion_date": "2017-07-03", "inspection_date": "2017-07-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.3, "quantity": "square metres"}, "party_wall_length": {"value": 9.25, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.99, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 359, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 322, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1808, "impact_of_loft_insulation": -326, "space_heating_existing_dwelling": 5202}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 51, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100061344397, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 9% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "KT13 8PR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WEYBRIDGE", "built_form": 2, "created_at": "2017-05-03 15:14:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "73, Greenlands Road", "assessment_type": "RdSAP", "completion_date": "2017-05-03", "inspection_date": "2017-05-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.15, "quantity": "square metres"}, "party_wall_length": {"value": 5.82, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 40.54, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 9, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 510, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 408, "currency": "GBP"}, "hot_water_cost_current": {"value": 186, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 89, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2818, "space_heating_existing_dwelling": 6443}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 80, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 200001391320, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG7 4DG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2017-05-03 21:39:25.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4 Seymour Court", "address_line_2": "Raleigh Street", "assessment_type": "RdSAP", "completion_date": "2017-05-03", "inspection_date": "2017-05-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 4, "heat_loss_corridor": 0}, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 56.94, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 320, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2033, "space_heating_existing_dwelling": 4331}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 176, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100080306077, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SL1 2NQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SLOUGH", "built_form": 4, "created_at": "2017-10-10 21:55:27.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16739}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Alexandra Road", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-03", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.73, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.73, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.26, "quantity": "square metres"}, "party_wall_length": 3.8, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 10.26, "quantity": "square metres"}, "party_wall_length": 3.8, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.57, "quantity": "square metres"}, "party_wall_length": 3.8, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 547, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 359, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2139, "impact_of_solid_wall_insulation": -2742, "space_heating_existing_dwelling": 8840}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 58, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 45110583, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR6 0AQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 4, "created_at": "2017-06-01 22:26:10.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Howick Park", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2016-12-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 15.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 15.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 733, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 470, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 237, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2135, "impact_of_loft_insulation": -4106, "space_heating_existing_dwelling": 10655}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 92, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100020264969, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA16 1EY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLING", "built_form": 1, "created_at": "2017-06-29 00:03:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16212}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 Burns House", "address_line_2": "Axminster Crescent", "assessment_type": "RdSAP", "completion_date": "2017-06-29", "inspection_date": "2017-06-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 4}, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.8, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 275, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 469, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1876, "impact_of_cavity_insulation": -2593, "space_heating_existing_dwelling": 7568}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 154, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090225330, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 63% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PE2 8HY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 3, "created_at": "2017-09-18 15:50:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10261}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "83, Thistle Drive", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.73, "quantity": "square metres"}, "party_wall_length": {"value": 5.31, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 34.73, "quantity": "square metres"}, "party_wall_length": {"value": 5.31, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 391, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 335, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2716, "space_heating_existing_dwelling": 6092}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 65, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050085080, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU12 8QZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HULL", "built_form": 2, "created_at": "2017-06-14 10:32:38.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Cloeberry Way", "address_line_2": "Hedon", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.13, "quantity": "square metres"}, "party_wall_length": {"value": 4.19, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 30.13, "quantity": "square metres"}, "party_wall_length": {"value": 4.19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.45, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 486, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 369, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 99, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2620, "space_heating_existing_dwelling": 5929}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100120038372, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS39 5PL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2017-10-12 09:41:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "16, Maynard Terrace", "address_line_2": "Clutton", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-09-04", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 184, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 24.96, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 44.55, "quantity": "square metres"}, "party_wall_length": {"value": 6.75, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 44.55, "quantity": "square metres"}, "party_wall_length": {"value": 6.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.98, "quantity": "square metres"}, "party_wall_length": {"value": 2.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 9.75, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 19.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 924, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 805, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2464, "impact_of_loft_insulation": -1858, "impact_of_solid_wall_insulation": -2557, "space_heating_existing_dwelling": 16689}, "energy_consumption_current": 157, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 107, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 35, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 35} +{"uprn": 100021868671, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW2 5PX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 6, "created_at": "2017-08-04 11:19:08.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "11, John Ashby Close", "assessment_type": "RdSAP", "completion_date": "2017-08-04", "inspection_date": "2017-07-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-08-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 43.24, "quantity": "square metres"}, "party_wall_length": {"value": 8.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 35.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 426, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 383, "currency": "GBP"}, "hot_water_cost_current": {"value": 205, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 44}], "co2_emissions_potential": 3.3, "energy_rating_potential": 61, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 205, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1531, "impact_of_loft_insulation": -524, "space_heating_existing_dwelling": 5151}, "energy_consumption_current": 490, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 452, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 44, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010897817, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BL3 6RH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 3, "created_at": "2017-06-22 12:30:28.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Lever Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.99, "quantity": "square metres"}, "party_wall_length": {"value": 5.39, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 38.99, "quantity": "square metres"}, "party_wall_length": {"value": 5.39, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 492, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 453, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 250, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1899, "impact_of_loft_insulation": -254, "space_heating_existing_dwelling": 8014}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100031044411, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NN9 5SW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLINGBOROUGH", "built_form": 1, "created_at": "2017-04-07 21:39:31.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16455}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Lakeside", "address_line_2": "Irthlingborough", "assessment_type": "RdSAP", "completion_date": "2017-04-07", "inspection_date": "2017-04-07", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 137, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-04-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.57, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 25.71, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 66.57, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 32.76, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.71, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 22.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 709, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 664, "currency": "GBP"}, "hot_water_cost_current": {"value": 155, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3151, "space_heating_existing_dwelling": 12622}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 22, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100100880100, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL14 2NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WREXHAM", "built_form": 2, "created_at": "2017-06-14 10:57:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15710}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "253, Ffordd Llanerch", "address_line_2": "Penycae", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.6, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.6, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 508, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 442, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2102, "space_heating_existing_dwelling": 7810}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 200002642484, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 84% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL65 3BE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOLYHEAD", "built_form": 1, "created_at": "2017-04-20 19:53:42.000000", "door_count": 4, "glazed_area": 2, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15935}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "131, Penrodyn", "address_line_2": "Valley", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 153, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 153.34, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 61.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 84, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 859, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 752, "currency": "GBP"}, "hot_water_cost_current": {"value": 160, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 160, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3370, "space_heating_existing_dwelling": 15541}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 10003307589, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "EX23 8RX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BUDE", "built_form": 3, "created_at": "2017-09-28 11:24:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "1, Binhamy Close", "assessment_type": "RdSAP", "completion_date": "2017-09-27", "inspection_date": "2017-09-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 46, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.86, "quantity": "square metres"}, "party_wall_length": {"value": 7.82, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 311, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 264, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1559, "space_heating_existing_dwelling": 3440}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.92, "energy_consumption_potential": 161, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10090321791, "roofs": [{"description": {"value": "Pitched, 400+ mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "B21 0UQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-05-26 09:33:00", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "92, Holliday Road", "address_line_2": "Handsworth", "assessment_type": "RdSAP", "completion_date": "2017-05-26", "inspection_date": "2017-05-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 1, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 390, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 26.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 38, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 323, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2041, "space_heating_existing_dwelling": 4436}, "energy_consumption_current": 79, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 62, "environmental_impact_current": 87, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 14, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 45112454, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR5 2RU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 4, "created_at": "2017-06-01 18:56:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "85, Edward Burdis Street", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-05-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.1, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 827, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 424, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 213, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1758, "impact_of_loft_insulation": -3682, "impact_of_cavity_insulation": -413, "impact_of_solid_wall_insulation": -639, "space_heating_existing_dwelling": 12275}, "energy_consumption_current": 427, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 105, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 44110764, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME4 4DE", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "CHATHAM", "built_form": 2, "created_at": "2017-09-28 16:56:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 10 Apni Haweli", "address_line_2": "2, Clover Street", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1, "unheated_corridor_length": 0}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 200, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38, "quantity": "square metres"}, "party_wall_length": {"value": 19, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 81, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 91, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 130, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1918, "space_heating_existing_dwelling": 838}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 218, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "B", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070189781, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV22 7HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUGBY", "built_form": 1, "created_at": "2017-08-09 09:14:47.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15705}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Lestock Close", "assessment_type": "RdSAP", "completion_date": "2017-08-09", "inspection_date": "2017-08-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 544, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 498, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2105, "impact_of_loft_insulation": -73, "space_heating_existing_dwelling": 9338}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100040692433, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BH24 2HG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RINGWOOD", "built_form": 1, "created_at": "2017-06-08 17:02:30.000000", "door_count": 4, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8874}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "16, Grosvenor Close", "address_line_2": "Ashley Heath", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-06-08", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 179, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 315, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.14, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 340, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 115.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 305, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 305, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 920, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 179, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 885, "currency": "GBP"}, "hot_water_cost_current": {"value": 148, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2993, "impact_of_cavity_insulation": -495, "space_heating_existing_dwelling": 15272}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 118, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100100578689, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF47 9HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MERTHYR TYDFIL", "built_form": 4, "created_at": "2017-06-08 20:57:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Church Street", "address_line_2": "Penydarren", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-06-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 560, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.61, "quantity": "square metres"}, "party_wall_length": {"value": 7.94, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.22, "quantity": "metres"}, "total_floor_area": {"value": 24.43, "quantity": "square metres"}, "party_wall_length": {"value": 7.88, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.16, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.22, "quantity": "metres"}, "total_floor_area": {"value": 15.33, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 719, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 182, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 189, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 161, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 175, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2665, "impact_of_solid_wall_insulation": -1091, "space_heating_existing_dwelling": 9591}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 100, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 26, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 3455041261, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ST4 7DS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2017-06-08 11:26:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 109, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Gerrard Street", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-06-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.759, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.03, "quantity": "square metres"}, "party_wall_length": {"value": 21.57, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.739, "quantity": "metres"}, "total_floor_area": {"value": 46.03, "quantity": "square metres"}, "party_wall_length": {"value": 21.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 978, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 502, "currency": "GBP"}, "hot_water_cost_current": {"value": 266, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 78, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 336, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 8, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 9, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 230, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3559, "impact_of_solid_wall_insulation": -4102, "space_heating_existing_dwelling": 10477}, "energy_consumption_current": 383, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 105, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW18 2DD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-06-13 20:32:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17645}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "32b Eglantine Road", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-06-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 67.25, "quantity": "square metres"}, "party_wall_length": {"value": 15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 10.15, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 708, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 301, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 7, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1813, "impact_of_loft_insulation": -615, "impact_of_solid_wall_insulation": -6313, "space_heating_existing_dwelling": 11883}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080891868, "roofs": [{"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SG2 8PS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STEVENAGE", "built_form": 2, "created_at": "2017-09-26 20:19:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "51, Park View", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 38.6, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.17, "quantity": "square metres"}, "party_wall_length": {"value": 7.43, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 43.17, "quantity": "square metres"}, "party_wall_length": {"value": 7.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.05, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 640, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 597, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2217, "impact_of_loft_insulation": -461, "space_heating_existing_dwelling": 11580}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 105, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 35, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 35} +{"uprn": 45131338, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SR3 3AX", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 07:47:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 20, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2306, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "55 Australia Tower", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-03-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 9, "heat_loss_corridor": 2, "unheated_corridor_length": 6.4}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.3, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 180, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63, "quantity": "square metres"}, "party_wall_length": {"value": 9.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 332, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Charging system linked to use of community heating, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 337, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 98}], "co2_emissions_potential": 2.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 126, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2232, "impact_of_solid_wall_insulation": -464, "space_heating_existing_dwelling": 4266}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 193, "environmental_impact_current": 96, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 98, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100100005652, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LL77 7TS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LLANGEFNI", "built_form": 4, "created_at": "2017-10-16 15:13:28.000000", "door_count": 0, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "28, Llawr y Dref", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-09-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.8}, "total_floor_area": 30, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.3, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 266, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 243, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 225, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 7, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.3, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2296, "impact_of_loft_insulation": -734, "impact_of_solid_wall_insulation": -394, "space_heating_existing_dwelling": 2156}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 244, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100061891980, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN12 4LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORTHING", "built_form": 1, "created_at": "2017-06-08 10:35:57.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8358}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "23a, Keymer Crescent", "address_line_2": "Goring-by-Sea", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-06-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 38.02, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 607, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 462, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2047, "space_heating_existing_dwelling": 8458}, "energy_consumption_current": 266, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 45048119, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE38 0NW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 2, "created_at": "2017-09-08 16:14:13.000000", "door_count": 0, "glazed_area": 4, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15705}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "false", "orientation": 1, "window_area": {"value": 1.44, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 1.44, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 0.4, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 0.72, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 1.44, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 3, "window_area": {"value": 0.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 1, "window_area": {"value": 4.2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 1, "window_area": {"value": 5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 3, "window_area": {"value": 4.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 1.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 3, "window_area": {"value": 0.32, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 1, "quantity": "square metres"}, "window_type": 2, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2.2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 1, "quantity": "square metres"}, "window_type": 2, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2.2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 5, "window_area": {"value": 1, "quantity": "square metres"}, "window_type": 2, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2.2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 5, "window_area": {"value": 2.34, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 0.98, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 1.56, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 0.91, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}}, {"orientation": 5, "window_area": {"value": 3, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Kielder", "assessment_type": "RdSAP", "completion_date": "2017-09-08", "inspection_date": "2017-09-08", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.65, "quantity": "square metres"}, "party_wall_length": {"value": 3.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.75, "quantity": "square metres"}, "party_wall_length": {"value": 3.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.5, "quantity": "square metres"}, "party_wall_length": {"value": 3.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 859, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 768, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2305, "impact_of_loft_insulation": -827, "space_heating_existing_dwelling": 13100}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 12111759, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "UB6 9TT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GREENFORD", "built_form": 2, "created_at": "2017-05-09 17:54:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16930}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "34a, Greenway Gardens", "assessment_type": "RdSAP", "completion_date": "2017-05-09", "inspection_date": "2017-05-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-05-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 46.9, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 474, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 270, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 178, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1651, "impact_of_loft_insulation": -425, "impact_of_solid_wall_insulation": -2985, "space_heating_existing_dwelling": 5881}, "energy_consumption_current": 279, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 163, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100051268417, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BD20 9PX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "KEIGHLEY", "built_form": 3, "created_at": "2017-05-08 16:53:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, The Maltings", "address_line_2": "Silsden", "assessment_type": "RdSAP", "completion_date": "2017-05-08", "inspection_date": "2017-05-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.19, "quantity": "square metres"}, "party_wall_length": {"value": 16.64, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 40.19, "quantity": "square metres"}, "party_wall_length": {"value": 16.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 589, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 452, "currency": "GBP"}, "hot_water_cost_current": {"value": 193, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2809, "space_heating_existing_dwelling": 7510}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10034816191, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR27 9RA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CROMER", "built_form": 4, "created_at": "2017-05-11 12:31:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3 Slade Court", "address_line_2": "Runton House Close", "address_line_3": "West Runton", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.5, "quantity": "metres"}}, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.145, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.42, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 380, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 345, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 79, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1954, "space_heating_existing_dwelling": 4586}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 157, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 32060972, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DY4 0RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TIPTON", "built_form": 4, "created_at": "2017-05-08 14:40:51.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "39, Highfield Road", "assessment_type": "RdSAP", "completion_date": "2017-05-08", "inspection_date": "2017-05-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.21, "quantity": "square metres"}, "party_wall_length": {"value": 6.43, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.67, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 36.86, "quantity": "square metres"}, "party_wall_length": {"value": 14.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 630, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 355, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 241, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 5, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1842, "impact_of_loft_insulation": -112, "impact_of_solid_wall_insulation": -5367, "space_heating_existing_dwelling": 11410}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 65, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10033397851, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B31 1RX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-06-09 15:42:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4032}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Walmesley Way", "assessment_type": "RdSAP", "completion_date": "2017-06-09", "inspection_date": "2017-06-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.51, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 19.73, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 41.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.73, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 502, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 163, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2821, "space_heating_existing_dwelling": 7122}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010089869, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CW1 4EX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CREWE", "built_form": 2, "created_at": "2017-06-08 21:51:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "34, Sorbus Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-06-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.5, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 37.3, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 740, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2174, "impact_of_solid_wall_insulation": -1921, "space_heating_existing_dwelling": 11857}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100061151062, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME20 7UF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AYLESFORD", "built_form": 3, "created_at": "2017-10-04 12:20:20.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Heathcote Close", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-05-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 352, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2503, "space_heating_existing_dwelling": 5237}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 61, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 5188852, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WC1H 8BA", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-09-11 15:40:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 950, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2704, "main_heating_category": 8, "main_heating_fraction": 1, "sap_main_heating_code": 424, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric underfloor heating", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "7, Birkenhead Street", "assessment_type": "RdSAP", "completion_date": "2017-09-11", "inspection_date": "2017-09-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.01, "quantity": "metres"}}, "total_floor_area": 20, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-09-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.01, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.147, "quantity": "square metres"}, "party_wall_length": {"value": 3.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 822, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 23, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 157, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 17, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 366, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 5, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 188, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 79}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 83}], "co2_emissions_potential": 0.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 19, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 209, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 193, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 117, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1623, "impact_of_solid_wall_insulation": -2334, "space_heating_existing_dwelling": 4951}, "energy_consumption_current": 917, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 210, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "F", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 156, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10007872375, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN15 6FB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KETTERING", "built_form": 3, "created_at": "2017-09-08 09:13:39.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8876}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Friston Close", "address_line_2": "Barton Seagrave", "assessment_type": "RdSAP", "completion_date": "2017-09-08", "inspection_date": "2017-09-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.71, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 34.71, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 370, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 370, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1994, "space_heating_existing_dwelling": 5420}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 38056913, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L14 9PY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2017-06-13 17:31:40.000000", "door_count": 4, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17216}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "155, Finch Lane", "address_line_2": "Knotty Ash", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-06-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.9, "quantity": "square metres"}, "party_wall_length": {"value": 4.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 20.21, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.46, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 517, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 369, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1783, "impact_of_cavity_insulation": -2042, "space_heating_existing_dwelling": 8593}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 81, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100040699311, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH21 3QD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIMBORNE", "built_form": 1, "created_at": "2017-08-17 07:16:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "31, Albert Road", "address_line_2": "Corfe Mullen", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 575, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 417, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2093, "impact_of_loft_insulation": -287, "impact_of_cavity_insulation": -2417, "space_heating_existing_dwelling": 10018}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 82, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10009715916, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TS24 0DW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARTLEPOOL", "built_form": 3, "created_at": "2017-07-04 15:08:33.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16144}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Earl Street", "assessment_type": "RdSAP", "completion_date": "2017-07-04", "inspection_date": "2017-07-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.86, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.89, "quantity": "square metres"}, "party_wall_length": {"value": 6.74, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 34.27, "quantity": "square metres"}, "party_wall_length": {"value": 6.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.83, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "150mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.88, "quantity": "square metres"}, "party_wall_length": {"value": 3.94, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 4.46, "quantity": "square metres"}, "party_wall_length": {"value": 2.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.23, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "150mm"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 816, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 789, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.9, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2105, "impact_of_loft_insulation": -3729, "space_heating_existing_dwelling": 12357}, "energy_consumption_current": 302, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 204, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45131184, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR3 3BA", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 08:19:40.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "32 Aldenham Tower", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-03-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 5, "heat_loss_corridor": 2, "unheated_corridor_length": 7.0}, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.0, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.4, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 230, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 160, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 98}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 98}], "co2_emissions_potential": 0.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1441, "impact_of_solid_wall_insulation": -629, "space_heating_existing_dwelling": 2326}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 120, "environmental_impact_current": 98, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "B", "environmental_impact_potential": 98, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10013572913, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH65 5FB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ELLESMERE PORT", "built_form": 3, "created_at": "2017-08-21 16:26:57.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Trinity Road", "assessment_type": "RdSAP", "completion_date": "2017-08-21", "inspection_date": "2017-08-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.09, "quantity": "square metres"}, "party_wall_length": {"value": 14.92, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 34.09, "quantity": "square metres"}, "party_wall_length": {"value": 14.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 251, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 251, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 93, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.4, "energy_rating_potential": 93, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1978, "space_heating_existing_dwelling": 2784}, "energy_consumption_current": 126, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 31, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100100110091, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CF3 5PJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2017-09-21 10:05:36", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17983}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "61, Bronte Crescent", "address_line_2": "Llanrumney", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 45}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.95, "quantity": "square metres"}, "party_wall_length": {"value": 5.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 41.95, "quantity": "square metres"}, "party_wall_length": {"value": 5.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 521, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 488, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2073, "impact_of_loft_insulation": -238, "space_heating_existing_dwelling": 7402}, "energy_consumption_current": 124, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061632955, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "KT14 7JE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEST BYFLEET", "built_form": 2, "created_at": "2017-08-23 13:19:46.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Dawson Road", "address_line_2": "Byfleet", "assessment_type": "RdSAP", "completion_date": "2017-08-23", "inspection_date": "2017-08-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.62, "quantity": "square metres"}, "party_wall_length": {"value": 6.84, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 33.62, "quantity": "square metres"}, "party_wall_length": {"value": 6.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.68, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.09, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.99, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 386, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 351, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2237, "impact_of_loft_insulation": -209, "space_heating_existing_dwelling": 5956}, "energy_consumption_current": 169, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 65, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100120811927, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "OX4 3SE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OXFORD", "built_form": 2, "created_at": "2017-07-21 15:18:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15101}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "34, Church Hill Road", "assessment_type": "RdSAP", "completion_date": "2017-07-21", "inspection_date": "2017-07-21", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 12.96, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.52, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 584, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 488, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2814, "impact_of_cavity_insulation": -2294, "space_heating_existing_dwelling": 10297}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10002930836, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 19% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BH24 2DS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "RINGWOOD", "built_form": 2, "created_at": "2017-04-18 13:31:15", "door_count": 6, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": 3, "main_heating_number": 1, "main_heating_control": 2205, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "true", "main_heating_data_source": 1, "main_heating_index_number": 102422}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, underfloor, electric", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "1 Cedar Gardens", "address_line_2": "110, Lions Lane", "address_line_3": "Ashley Heath", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-03-24", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.07, "quantity": "metres"}}, "total_floor_area": 75, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.9578, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.12, "quantity": "square metres"}, "party_wall_length": {"value": 5.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.88, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 19, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 149, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and at least two room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 155, "currency": "GBP"}, "hot_water_cost_current": {"value": 242, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 242, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2751, "space_heating_existing_dwelling": 3795}, "energy_consumption_current": 130, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010011388, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CH4 7QS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTER", "built_form": 1, "created_at": "2017-08-29 06:42:59.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1727}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Five Ashes Road", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-08-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.2, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 46.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 824, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 618, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 8, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 206, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2201, "impact_of_loft_insulation": -466, "space_heating_existing_dwelling": 10075}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 144, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100050070865, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU13 9DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "HESSLE", "built_form": 3, "created_at": "2017-07-05 06:38:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "30, Bedford Road", "assessment_type": "RdSAP", "completion_date": "2017-07-05", "inspection_date": "2017-07-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.05, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 30.7, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.5, "quantity": "square metres"}, "party_wall_length": {"value": 3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 751, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 491, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 193, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2331, "impact_of_loft_insulation": -283, "impact_of_cavity_insulation": -328, "impact_of_solid_wall_insulation": -4029, "space_heating_existing_dwelling": 12827}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 114, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100080500857, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HP7 0BP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AMERSHAM", "built_form": 4, "created_at": "2017-09-26 20:56:10.000000", "door_count": 4, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15106}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "47, Highover Park", "assessment_type": "RdSAP", "completion_date": "2017-09-26", "inspection_date": "2017-09-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 127, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 6, "registration_date": "2017-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 10.48, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 9.4, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.7, "quantity": "square metres"}, "party_wall_length": {"value": 9.63, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.09, "quantity": "metres"}, "total_floor_area": {"value": 27.7, "quantity": "square metres"}, "party_wall_length": {"value": 9.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 27.7, "quantity": "square metres"}, "party_wall_length": {"value": 9.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.09, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.48, "quantity": "square metres"}, "party_wall_length": 4.37, "floor_construction": 0, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 16.48, "quantity": "square metres"}, "party_wall_length": 4.37, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 929, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 688, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2954, "impact_of_loft_insulation": -900, "impact_of_cavity_insulation": -4547, "space_heating_existing_dwelling": 17828}, "energy_consumption_current": 245, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 125, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 4510128617, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE6 3DZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 3, "created_at": "2017-08-08 19:46:04.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "45, Proctor Court", "assessment_type": "RdSAP", "completion_date": "2017-08-08", "inspection_date": "2017-08-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 9, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.4, "quantity": "metres"}}, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.318, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 100, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 67.62, "quantity": "square metres"}, "party_wall_length": {"value": 14.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 454, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 353, "currency": "GBP"}, "hot_water_cost_current": {"value": 248, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 206, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 303, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 262, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1803, "space_heating_existing_dwelling": 5100}, "energy_consumption_current": 333, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 297, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100023052683, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 23% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "IG8 0PP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOODFORD GREEN", "built_form": 2, "created_at": "2017-08-01 16:20:59.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15106}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Barclay Oval", "assessment_type": "RdSAP", "completion_date": "2017-08-01", "inspection_date": "2017-08-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 180, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 43.59, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.871, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.297, "quantity": "square metres"}, "party_wall_length": {"value": 7.996, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.043, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.714, "quantity": "metres"}, "total_floor_area": {"value": 46.457, "quantity": "square metres"}, "party_wall_length": {"value": 7.996, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.043, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.302, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.501, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.682, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.599, "quantity": "metres"}, "total_floor_area": {"value": 20.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.501, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.682, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 23, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1443, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 158, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 627, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 21, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 332, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 333, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 75}, {"sequence": 8, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3176, "impact_of_loft_insulation": -199, "impact_of_solid_wall_insulation": -6526, "space_heating_existing_dwelling": 29093}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 25, "calculation_software_version": "1.0.x", "energy_consumption_potential": 80, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 42052576, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CH44 5UJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 3, "created_at": "2017-08-17 13:39:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8497}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Hartington Road", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.59, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 38.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.74, "quantity": "square metres"}, "party_wall_length": {"value": 3.18, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.56, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 10.74, "quantity": "square metres"}, "party_wall_length": {"value": 3.18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1051, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 430, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2230, "impact_of_loft_insulation": -252, "impact_of_solid_wall_insulation": -6850, "space_heating_existing_dwelling": 14752}, "energy_consumption_current": 314, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 81, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 83064171, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HD2 2JJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 1, "created_at": "2017-08-01 16:42:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15166}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "45, Cumberland Avenue", "assessment_type": "RdSAP", "completion_date": "2017-08-01", "inspection_date": "2017-08-01", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 168, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.62, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 73.64, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35.68, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1021, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 937, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 4.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 87, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2331, "impact_of_loft_insulation": -528, "space_heating_existing_dwelling": 17736}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 148, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100091436985, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM16 5DZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EPPING", "built_form": 2, "created_at": "2017-06-02 08:45:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8560}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "58a, Lincolns Field", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-06-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.528, "quantity": "metres"}, "total_floor_area": {"value": 66.247664, "quantity": "square metres"}, "party_wall_length": {"value": 7.148, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.684, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 321, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 290, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2669, "space_heating_existing_dwelling": 3856}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 152, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200023421, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "N2 0UY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-06-01 14:14:06.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Clare Close", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-06-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 13, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 523, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2091, "impact_of_loft_insulation": -435, "space_heating_existing_dwelling": 7175}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 39024450, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WA9 1LX", "hot_water": {"description": {"value": "Gas multipoint", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ST. HELENS", "built_form": 4, "created_at": "2017-09-05 10:58:09.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 612, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Graham Street", "assessment_type": "RdSAP", "completion_date": "2017-09-05", "inspection_date": "2017-09-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-09-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.35, "quantity": "square metres"}, "party_wall_length": {"value": 6.76, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 25.35, "quantity": "square metres"}, "party_wall_length": {"value": 6.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.12, "quantity": "square metres"}, "party_wall_length": {"value": 2.18, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 24, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 328, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 26}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 30}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 32}, {"sequence": 4, "typical_saving": {"value": 810, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 31, "environmental_impact_rating": 27}, {"sequence": 2, "typical_saving": {"value": 793, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 743, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 759, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1377, "impact_of_cavity_insulation": -858, "space_heating_existing_dwelling": 6999}, "energy_consumption_current": 708, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["A"], "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 21, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 125, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 60017629, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 39% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN43 6BG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "SHOREHAM-BY-SEA", "built_form": 2, "created_at": "2017-08-01 12:56:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "214, Upper Shoreham Road", "assessment_type": "RdSAP", "completion_date": "2017-08-01", "inspection_date": "2017-08-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.87, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 44.87, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.46, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.21, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 39, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 492, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 44, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1628, "impact_of_loft_insulation": -456, "space_heating_existing_dwelling": 8645}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 83, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200002868184, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV33 9LB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEAMINGTON SPA", "built_form": 1, "created_at": "2017-08-12 09:12:44", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 5, "rooms_with_mixer_shower_no_bath": 4, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9301}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Farmhouse Windmill Hill Farm", "address_line_2": "Windmill Hill Lane", "address_line_3": "Chesterton", "assessment_type": "RdSAP", "completion_date": "2017-08-12", "inspection_date": "2017-08-01", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 404, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "registration_date": "2017-08-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 53.64, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.04, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 73.11, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 32.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 43.69, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.14, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 60.99, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.99, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2386, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 17, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 177, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1719, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 583, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 602, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "co2_emissions_potential": 9.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 177, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 131, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3011, "impact_of_loft_insulation": -3949, "impact_of_solid_wall_insulation": -12617, "space_heating_existing_dwelling": 48790}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 91, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 74, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 65} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA1 2TY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 4, "created_at": "2017-07-05 10:23:06.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "71a Station Road", "assessment_type": "RdSAP", "completion_date": "2017-07-05", "inspection_date": "2017-07-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-07-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 45.22, "quantity": "square metres"}, "party_wall_length": {"value": 10.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 594, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 33, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 1, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 59}], "co2_emissions_potential": 2.5, "energy_rating_potential": 60, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1625, "impact_of_loft_insulation": -3708, "impact_of_solid_wall_insulation": -1199, "space_heating_existing_dwelling": 7080}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 316, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10070094108, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE4 2SD", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MATLOCK", "built_form": 2, "created_at": "2017-04-02 10:46:38.000000", "door_count": 0, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2304, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 31 Underhall", "address_line_2": "Chesterfield Road", "address_line_3": "Two Dales", "assessment_type": "RdSAP", "completion_date": "2017-04-02", "inspection_date": "2017-04-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-04-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 35.88, "quantity": "square metres"}, "party_wall_length": {"value": 17.17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 195, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 195, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1947, "space_heating_existing_dwelling": 1740}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 203, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 68119680, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH6 7LW", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "HORLEY", "built_form": 2, "created_at": "2017-08-02 14:44:54.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Crescent Way", "assessment_type": "RdSAP", "completion_date": "2017-08-02", "inspection_date": "2017-08-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-08-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.01, "quantity": "square metres"}, "party_wall_length": {"value": 6.47, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 41.52, "quantity": "square metres"}, "party_wall_length": {"value": 6.47, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1607, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 27, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 805, "currency": "GBP"}, "hot_water_cost_current": {"value": 298, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 91, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 390, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 24}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 27}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 27}, {"sequence": 4, "typical_saving": {"value": 422, "currency": "GBP"}, "indicative_cost": "\u00a32,000 - \u00a33,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 35}, {"sequence": 5, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 39}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a31,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 40}, {"sequence": 7, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 46}], "co2_emissions_potential": 4.9, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 41, "environmental_impact_rating": 26}, {"sequence": 2, "typical_saving": {"value": 486, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 88}, {"sequence": 3, "typical_saving": {"value": 491, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2148, "impact_of_loft_insulation": -4693, "impact_of_cavity_insulation": -4628, "space_heating_existing_dwelling": 18298}, "energy_consumption_current": 774, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 348, "environmental_impact_current": 15, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "F", "environmental_impact_potential": 46, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 131, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10090356691, "roofs": [{"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "MK2 2FE", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MILTON KEYNES", "built_form": 4, "created_at": "2017-09-01 18:28:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "26 Ambassador House", "address_line_2": "219, Queensway", "address_line_3": "Bletchley", "assessment_type": "RdSAP", "completion_date": "2017-09-01", "inspection_date": "2017-09-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 1, "unheated_corridor_length": {"value": 0, "quantity": "metres"}}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 58.46, "quantity": "square metres"}, "party_wall_length": {"value": 24.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 253, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 7, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1979, "space_heating_existing_dwelling": 2844}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 164, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100100223053, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CH5 2SN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DEESIDE", "built_form": 2, "created_at": "2017-06-15 18:10:08.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Claremont Avenue", "address_line_2": "Garden City", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.39, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 42.48, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.83, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 519, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 74, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 43, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1586, "space_heating_existing_dwelling": 8638}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 90, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100031062149, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NN15 6HS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KETTERING", "built_form": 2, "created_at": "2017-08-01 13:56:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "34, Highfield Road", "assessment_type": "RdSAP", "completion_date": "2017-08-01", "inspection_date": "2017-08-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.01, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 35.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.01, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 451, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 419, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2007, "impact_of_loft_insulation": -225, "space_heating_existing_dwelling": 7039}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 97, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 2465009785, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE3 1QX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 4, "created_at": "2017-08-31 14:44:46.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 914, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2100, "main_heating_category": 2, "main_heating_fraction": 0, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "40, Morcote Road", "assessment_type": "RdSAP", "completion_date": "2017-08-31", "inspection_date": "2017-08-31", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.68, "quantity": "square metres"}, "party_wall_length": {"value": 5.87, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 33.46, "quantity": "square metres"}, "party_wall_length": {"value": 9.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.71, "quantity": "square metres"}, "party_wall_length": {"value": 3.52, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 483, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 441, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2161, "impact_of_loft_insulation": -227, "space_heating_existing_dwelling": 7331}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 112, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10070101522, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DE4 3JG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MATLOCK", "built_form": 4, "created_at": "2017-04-11 17:21:35.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16919}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "105, Smedley Street", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 28.27, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "100mm"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.4, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.89, "quantity": "metres"}, "total_floor_area": {"value": 34.4, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 34.4, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1286, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 634, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 242, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 194, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2169, "impact_of_loft_insulation": -569, "impact_of_solid_wall_insulation": -3321, "space_heating_existing_dwelling": 22298}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 113, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100021001525, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SE18 5LF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-06-27 03:08:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "77, Samuel Street", "assessment_type": "RdSAP", "completion_date": "2017-06-27", "inspection_date": "2017-06-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 40.43, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 40.43, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 330, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 226, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}}], "hot_water_cost_potential": {"value": 107, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2118, "impact_of_cavity_insulation": -2280, "space_heating_existing_dwelling": 4574}, "energy_consumption_current": 140, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 98, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010566423, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PR2 1XA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRESTON", "built_form": 2, "created_at": "2017-09-08 17:46:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1711}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "138, Savick Way", "address_line_2": "Lea", "assessment_type": "RdSAP", "completion_date": "2017-09-08", "inspection_date": "2017-09-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.28, "quantity": "square metres"}, "party_wall_length": {"value": 6.67, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 28.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 456, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 377, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1808, "space_heating_existing_dwelling": 5990}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 99, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10006748929, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HX6 2BB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOWERBY BRIDGE", "built_form": 3, "created_at": "2017-05-02 18:01:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2, Norland View", "assessment_type": "RdSAP", "completion_date": "2017-05-02", "inspection_date": "2017-05-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.33, "quantity": "square metres"}, "party_wall_length": {"value": 8.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.83, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 43.33, "quantity": "square metres"}, "party_wall_length": {"value": 8.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.83, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 601, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 527, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2163, "space_heating_existing_dwelling": 8799}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 123, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 422000024483, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "OL2 7SG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OLDHAM", "built_form": 3, "created_at": "2017-07-04 19:01:32.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9569}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "112, Alfred Street", "address_line_2": "Shaw", "assessment_type": "RdSAP", "completion_date": "2017-07-04", "inspection_date": "2017-07-04", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-07-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.91, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.1, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.85, "quantity": "metres"}, "total_floor_area": {"value": 44.1, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1075, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 494, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 427, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 8, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2028, "impact_of_loft_insulation": -770, "impact_of_solid_wall_insulation": -6516, "space_heating_existing_dwelling": 14546}, "energy_consumption_current": 440, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100062034189, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "high_exposure": "true", "addendum_numbers": [6]}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SO16 4DU", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2017-07-20 14:59:52.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2306, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 42 Sturminster House", "address_line_2": "Irving Road", "assessment_type": "RdSAP", "completion_date": "2017-07-20", "inspection_date": "2017-07-04", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 7, "heat_loss_corridor": 2, "unheated_corridor_length": 3.42}, "total_floor_area": 72, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.9344, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 64.28, "quantity": "square metres"}, "party_wall_length": {"value": 26.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.31, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.25, "quantity": "square metres"}, "party_wall_length": {"value": 5.39, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.5, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "100mm", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 239, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Charging system linked to use of community heating, programmer and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 207, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 116, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2115, "space_heating_existing_dwelling": 2735}, "energy_consumption_current": 139, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 116, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10003503902, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "EX39 2DR", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BIDEFORD", "built_form": 4, "created_at": "2017-06-06 21:44:18.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "10 Market Place", "assessment_type": "RdSAP", "completion_date": "2017-06-06", "inspection_date": "2017-05-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.8, "quantity": "metres"}}, "total_floor_area": 27, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-06-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 480, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.88, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 27.14, "quantity": "square metres"}, "party_wall_length": {"value": 12.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 259, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 183, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.1, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 22, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2957, "impact_of_loft_insulation": -280, "impact_of_solid_wall_insulation": -482, "space_heating_existing_dwelling": 2729}, "energy_consumption_current": 384, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "9.0.0", "energy_consumption_potential": 230, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 5870081496, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 47% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SM6 7DD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLINGTON", "built_form": 2, "created_at": "2017-04-26 16:06:06.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16986}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "286, London Road", "assessment_type": "RdSAP", "completion_date": "2017-04-26", "inspection_date": "2017-04-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 105, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.08, "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 52.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 47, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 817, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 499, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2054, "impact_of_loft_insulation": -506, "impact_of_cavity_insulation": -2748, "impact_of_solid_wall_insulation": -1669, "space_heating_existing_dwelling": 12585}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100081145892, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WD17 4NW", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WATFORD", "built_form": 1, "created_at": "2017-04-03 13:23:31.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "31, Elton Park", "assessment_type": "RdSAP", "completion_date": "2017-04-03", "inspection_date": "2017-04-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 50, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-04-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 541, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 323, "currency": "GBP"}, "hot_water_cost_current": {"value": 155, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 54}], "co2_emissions_potential": 3.1, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 206, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "hot_water_cost_potential": {"value": 155, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1822, "space_heating_existing_dwelling": 6137}, "energy_consumption_current": 516, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 367, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 87, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100021254636, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 48% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HA3 8LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 2, "created_at": "2017-09-22 15:26:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "47, Brampton Grove", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 136, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 31.84, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.48, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 43.48, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.04, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.76, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 48, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1494, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 130, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1080, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 97, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 110, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 3, "typical_saving": {"value": 229, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 57}], "co2_emissions_potential": 5.1, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 297, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 50}}], "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2308, "impact_of_loft_insulation": -860, "impact_of_cavity_insulation": -1002, "impact_of_solid_wall_insulation": -3914, "space_heating_existing_dwelling": 24848}, "energy_consumption_current": 352, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 209, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 42, "current_energy_efficiency_band": "E", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100031844271, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST11 9PJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 1, "created_at": "2017-07-18 17:53:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17856}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "1, Barlstone Avenue", "address_line_2": "Blythe Bridge", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 49, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 476, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 365, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1826, "impact_of_loft_insulation": -1174, "space_heating_existing_dwelling": 7828}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 100, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 200000427177, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 81% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS21 1PW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKTON-ON-TEES", "built_form": 2, "created_at": "2017-07-05 07:46:51.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15981}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Hall Close", "address_line_2": "Carlton", "assessment_type": "RdSAP", "completion_date": "2017-07-05", "inspection_date": "2017-07-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 143, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.15, "quantity": "square metres"}, "party_wall_length": {"value": 8.44, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 10.99, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 45.15, "quantity": "square metres"}, "party_wall_length": {"value": 8.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.57, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.67, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 26.57, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 81, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 802, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 802, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2316, "impact_of_loft_insulation": -140, "space_heating_existing_dwelling": 13424}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 146, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100040891412, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 32% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TA7 9HF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "BRIDGWATER", "built_form": 1, "created_at": "2017-08-18 15:53:45", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16868}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "22, Manor Road", "address_line_2": "Catcott", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-18", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 178, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 57.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 21.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 32, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 2008, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 27, "lighting_cost_current": {"value": 151, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1019, "currency": "GBP"}, "hot_water_cost_current": {"value": 203, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 361, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 552, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3160", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.9, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 140, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2636, "impact_of_solid_wall_insulation": -6757, "space_heating_existing_dwelling": 25807}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 80, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 47, "current_energy_efficiency_band": "F", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 200000666912, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG18 2QU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANSFIELD", "built_form": 2, "created_at": "2017-09-23 11:46:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16919}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Linnet Drive", "assessment_type": "RdSAP", "completion_date": "2017-09-23", "inspection_date": "2017-09-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.71, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 28.71, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 412, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1776, "impact_of_loft_insulation": -309, "space_heating_existing_dwelling": 6953}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 108, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10002334909, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL3 8WF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SLOUGH", "built_form": 4, "created_at": "2017-10-27 17:07:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8575}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "109, Grasholm Way", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 1}, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 84.86, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 262, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 244, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2418, "space_heating_existing_dwelling": 2825}, "energy_consumption_current": 121, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 1775008929, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 14% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PO1 4EP", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PORTSMOUTH", "built_form": 5, "created_at": "2017-10-05 12:26:36.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 25", "address_line_2": "Barkis House", "address_line_3": "Brownlow Close", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": 1.22}, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 190, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.7938, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 80, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 81.65, "quantity": "square metres"}, "party_wall_length": {"value": 21.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 279, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, programmer and TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 287, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.0, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 127, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2198, "space_heating_existing_dwelling": 3296}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 138, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100050732505, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN3 2PQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DONCASTER", "built_form": 2, "created_at": "2017-08-14 22:30:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1994}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "55, Hartland Crescent", "address_line_2": "Edenthorpe", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.42, "quantity": "square metres"}, "party_wall_length": {"value": 6.96, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 38.42, "quantity": "square metres"}, "party_wall_length": {"value": 6.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 642, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 520, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2782, "impact_of_loft_insulation": -2346, "space_heating_existing_dwelling": 9901}, "energy_consumption_current": 288, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 139, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090379060, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SS8 7SJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CANVEY ISLAND", "built_form": 1, "created_at": "2017-08-14 21:32:25.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8440}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "21a, Oxford Road", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 473, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 281, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 8, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 9, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.3, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 41, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1631, "impact_of_loft_insulation": -467, "space_heating_existing_dwelling": 6400}, "energy_consumption_current": 326, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 31, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 45123216, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SR3 4BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-01 23:48:55.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "95, Torquay Road", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2017-03-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 49, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1001, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 638, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 115, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 8, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 253, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2228, "space_heating_existing_dwelling": 12609}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 125, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080203678, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 27% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG12 0UN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BRACKNELL", "built_form": 3, "created_at": "2017-07-16 17:51:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "23, Nuthurst", "assessment_type": "RdSAP", "completion_date": "2017-07-16", "inspection_date": "2017-07-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 43.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 597, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 391, "currency": "GBP"}, "hot_water_cost_current": {"value": 198, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 7, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 176, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 178, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3076, "space_heating_existing_dwelling": 6973}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 72, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090434591, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 26% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SS11 7NJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WICKFORD", "built_form": 2, "created_at": "2017-09-15 10:08:05.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9949}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "44, Brock Hill", "address_line_2": "Runwell", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 45.59, "insulation": 2, "roof_room_connected": "Y", "construction_age_band": "F", "roof_insulation_thickness": "300mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.53, "quantity": "square metres"}, "party_wall_length": {"value": 9.67, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.89, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 26, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 702, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 117, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 478, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 82, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 130, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2937, "impact_of_loft_insulation": -234, "impact_of_cavity_insulation": -914, "space_heating_existing_dwelling": 10716}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 84, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100040929009, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TA2 6HX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TAUNTON", "built_form": 4, "created_at": "2017-06-15 07:21:28.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1749}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "71, Greenway Avenue", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 120, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 15.06, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.71, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 34.96, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.91, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 8.91, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 7.56, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1468, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 746, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 60, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 339, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.9, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 169, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2289, "impact_of_loft_insulation": -2853, "impact_of_solid_wall_insulation": -5736, "space_heating_existing_dwelling": 23049}, "energy_consumption_current": 380, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 65, "calculation_software_version": "9.0.0", "energy_consumption_potential": 137, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090433550, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 65% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CM1 2AT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHELMSFORD", "built_form": 2, "created_at": "2017-10-14 12:36:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Woodland Road", "assessment_type": "RdSAP", "completion_date": "2017-10-14", "inspection_date": "2017-10-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 164, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 10, "pvc_window_frames": "true", "registration_date": "2017-10-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.98, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.62, "quantity": "metres"}, "total_floor_area": {"value": 42.98, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.62, "quantity": "metres"}, "total_floor_area": {"value": 25.36, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 65, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 996, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 863, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 138, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2451, "impact_of_loft_insulation": -3888, "impact_of_solid_wall_insulation": -3324, "space_heating_existing_dwelling": 19346}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 135, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 10012979045, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR33 7RS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LOWESTOFT", "built_form": 3, "created_at": "2017-08-14 16:38:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9725}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, High Path", "address_line_2": "Kessingland", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 11, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.7, "quantity": "square metres"}, "party_wall_length": {"value": 3.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 11.7, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 866, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 417, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 341, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2181, "impact_of_solid_wall_insulation": -6350, "space_heating_existing_dwelling": 13864}, "energy_consumption_current": 309, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 12081727, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W5 4EA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-08-14 19:36:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9571}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "44, Little Ealing Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "total_floor_area": {"value": 70.32, "quantity": "square metres"}, "party_wall_length": {"value": 15.18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 838, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 550, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.9, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 56}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2005, "impact_of_loft_insulation": -4898, "impact_of_solid_wall_insulation": -4353, "space_heating_existing_dwelling": 14071}, "energy_consumption_current": 377, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.12r11", "energy_consumption_potential": 236, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100030519990, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LE6 0DH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-08-14 13:22:03", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10337}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Jonathan Close", "address_line_2": "Groby", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 120, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 606, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 89, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 611, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2290, "space_heating_existing_dwelling": 10713}, "energy_consumption_current": 87, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 73, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "B", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 16, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100021260, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM8 2EA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAGENHAM", "built_form": 2, "created_at": "2017-09-14 17:39:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 3, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16211}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, Mayesbrook Road", "assessment_type": "RdSAP", "completion_date": "2017-09-14", "inspection_date": "2017-09-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 125, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 9, "registration_date": "2017-09-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.58, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.5, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 24.1, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 595, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 500, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 101, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2187, "impact_of_loft_insulation": -217, "impact_of_cavity_insulation": -2104, "space_heating_existing_dwelling": 10515}, "energy_consumption_current": 154, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 86, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 21, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 21} +{"uprn": 100100360254, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 46% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SA1 7BD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}, "post_town": "SWANSEA", "built_form": 3, "created_at": "2017-09-14 13:05:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 3, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 3, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "7, Seaview Terrace", "address_line_2": "Bonymaen", "assessment_type": "RdSAP", "completion_date": "2017-09-14", "inspection_date": "2017-09-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-09-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.21, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 39.21, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.09, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.31, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1206, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 774, "currency": "GBP"}, "hot_water_cost_current": {"value": 290, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 163, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 79}, {"sequence": 9, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 97}], "co2_emissions_potential": -0.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 38, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 181, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2202, "impact_of_cavity_insulation": -1247, "space_heating_existing_dwelling": 9209}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": -53, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "F", "environmental_impact_potential": 97, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040838280, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH15 4NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 3, "created_at": "2017-07-26 22:38:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 15690}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "93, Walcheren Place", "assessment_type": "RdSAP", "completion_date": "2017-07-26", "inspection_date": "2017-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.8, "quantity": "square metres"}, "party_wall_length": {"value": 5.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 42.8, "quantity": "square metres"}, "party_wall_length": {"value": 5.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.35, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "150mm"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 412, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 330, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 5, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2845, "space_heating_existing_dwelling": 5489}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 43, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100051206510, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD2 1PF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRADFORD", "built_form": 2, "created_at": "2017-06-19 22:07:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8357}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Plumpton Gardens", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.73, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 34.17, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 604, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 475, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2000, "space_heating_existing_dwelling": 7739}, "energy_consumption_current": 258, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": 9.92, "energy_consumption_potential": 114, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10013887101, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 45% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL7 6FQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "CIRENCESTER", "built_form": 1, "created_at": "2017-04-18 19:46:20", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 27, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15444}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and underfloor heating, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "20 Howells Mere", "address_line_2": "Lower Mill Estate", "address_line_3": "Sommerford Keynes", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-14", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 193, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 50.05, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 85.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 38.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 85.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 38.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 991, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1010, "currency": "GBP"}, "hot_water_cost_current": {"value": 201, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 95, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2539, "space_heating_existing_dwelling": 12141}, "energy_consumption_current": 111, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 70, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": null, "roofs": [{"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W10 6NB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-27 15:09:28.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "34a Kelfield Gardens", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-27", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.97, "quantity": "metres"}}, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.6793, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.48, "quantity": "square metres"}, "party_wall_length": {"value": 10.03, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 504, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 426, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 40, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1894, "impact_of_solid_wall_insulation": -1037, "space_heating_existing_dwelling": 8541}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 152, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 422000104402, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OL1 2NP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OLDHAM", "built_form": 4, "created_at": "2017-10-19 14:15:28.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16909}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "8, Yasmin Gardens", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2016-11-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.51, "quantity": "square metres"}, "party_wall_length": {"value": 8.94, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 31.51, "quantity": "square metres"}, "party_wall_length": {"value": 8.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 379, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 354, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 249, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 1.0, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1850, "impact_of_loft_insulation": -219, "space_heating_existing_dwelling": 5782}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 84, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 45126003, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DH4 6JQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-05-31 23:37:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Grange Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2016-12-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 602, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 501, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2127, "space_heating_existing_dwelling": 8404}, "energy_consumption_current": 214, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 45, "calculation_software_version": "1.0.x", "energy_consumption_potential": 104, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 47070414, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE29 8DN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NORTH SHIELDS", "built_form": 2, "created_at": "2017-10-05 08:19:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "7, Peebles Close", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 520, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 222, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 58}], "co2_emissions_potential": 3.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 218, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1631, "space_heating_existing_dwelling": 5854}, "energy_consumption_current": 468, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 348, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 58, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 6152821, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E1 4UN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-05 16:42:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16694}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "106a, Mile End Road", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-05", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 98, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.639, "quantity": "metres"}, "total_floor_area": {"value": 40.6, "quantity": "square metres"}, "party_wall_length": {"value": 15.906, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.868, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.368, "quantity": "metres"}, "total_floor_area": {"value": 40.6, "quantity": "square metres"}, "party_wall_length": {"value": 15.906, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 17.101, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 16.946, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 740, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No time or thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 486, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.8, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2244, "impact_of_loft_insulation": -3812, "impact_of_solid_wall_insulation": -2899, "space_heating_existing_dwelling": 12683}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 42, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 163, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 19, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK40 2RX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 2, "created_at": "2017-10-04 15:22:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "96 Tavistock Street", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-04", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 20.53, "quantity": "square metres"}, "party_wall_length": {"value": 5.43, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 9.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 18.63, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 453, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 288, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.5, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1534, "impact_of_solid_wall_insulation": -2366, "space_heating_existing_dwelling": 6538}, "energy_consumption_current": 344, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 221, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100485510, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF35 6HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIDGEND", "built_form": 2, "created_at": "2017-10-09 09:28:43.000000", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9209}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, High Street", "address_line_2": "Heol-y-Cyw", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 150, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.71, "quantity": "square metres"}, "party_wall_length": {"value": 7.11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 42.05, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.61, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 28.5, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 18.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 846, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 651, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 133, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2319, "impact_of_loft_insulation": -486, "impact_of_cavity_insulation": -1741, "space_heating_existing_dwelling": 13932}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 30, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 24} +{"uprn": 10008526621, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN36 5HP", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 4, "created_at": "2017-10-26 15:01:45.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "8, Sarge Close", "address_line_2": "Holton-le-Clay", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.21, "quantity": "square metres"}, "party_wall_length": {"value": 15.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 236, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.5, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1910, "impact_of_loft_insulation": -256, "space_heating_existing_dwelling": 2538}, "energy_consumption_current": 189, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 189, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090846066, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR29 4ES", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "GREAT YARMOUTH", "built_form": 2, "created_at": "2017-10-16 15:30:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15454}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "21, Lexington Close", "address_line_2": "Hemsby", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 588, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 541, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2051, "impact_of_loft_insulation": -236, "space_heating_existing_dwelling": 6675}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 62, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100011470887, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [11]}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SK2 6TJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 2, "created_at": "2017-10-20 14:35:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, College Close", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.43, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 34.43, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.67, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 410, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 375, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2161, "impact_of_loft_insulation": -374, "space_heating_existing_dwelling": 6467}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100120867971, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX33 1UP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "OXFORD", "built_form": 1, "created_at": "2017-10-20 11:39:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1845}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "25, Beech Road", "address_line_2": "Wheatley", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 77.27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 35.37, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 754, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 341, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 169, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5185, "impact_of_loft_insulation": -771, "space_heating_existing_dwelling": 10308}, "energy_consumption_current": 370, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 122, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100030579201, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DE12 7HR", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "SWADLINCOTE", "built_form": 4, "created_at": "2017-10-12 14:24:29.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "55a, High Street", "address_line_2": "Measham", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.8, "quantity": "metres"}}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.04, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 3, "wall_insulation_type": 5, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 51.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 995, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 679, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 26}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 26}, {"sequence": 3, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 35}], "co2_emissions_potential": 5.2, "energy_rating_potential": 57, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 435, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 318, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 139, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1627, "impact_of_loft_insulation": -713, "impact_of_solid_wall_insulation": -3446, "space_heating_existing_dwelling": 11294}, "energy_consumption_current": 792, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 599, "environmental_impact_current": 24, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 35, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 134, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 170324, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS14 0NN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 4, "created_at": "2017-10-16 13:16:21.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "37, Coulsons Road", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.83, "quantity": "square metres"}, "party_wall_length": {"value": 16.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 38.96, "quantity": "square metres"}, "party_wall_length": {"value": 16.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.56, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 369, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 346, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2108, "space_heating_existing_dwelling": 5571}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 58, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110659558, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE63 9TT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHINGTON", "built_form": 2, "created_at": "2017-10-17 11:02:43.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, Woodlands Road", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.92, "quantity": "square metres"}, "party_wall_length": {"value": 7.64, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.01, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37.72, "quantity": "square metres"}, "party_wall_length": {"value": 6.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.81, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.18, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 645, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 586, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2667, "space_heating_existing_dwelling": 9336}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 122, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 2630119554, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NR16 1JS", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "NORWICH", "built_form": 2, "created_at": "2017-10-10 18:14:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 633, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Portable electric heaters assumed for most rooms", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Spicers Lane", "address_line_2": "Forncett St. Mary", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.31, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.53, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 32.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.31, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.1, "quantity": "square metres"}, "party_wall_length": {"value": 1.86, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 2808, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.9, "energy_rating_average": 60, "energy_rating_current": 4, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 2022, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 647, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 17, "environmental_impact_rating": 29}, {"sequence": 2, "typical_saving": {"value": 167, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 20, "environmental_impact_rating": 32}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 21, "environmental_impact_rating": 33}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 22, "environmental_impact_rating": 35}, {"sequence": 5, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 41}], "co2_emissions_potential": 5.9, "energy_rating_potential": 29, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 19, "environmental_impact_rating": 31}}], "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2140, "impact_of_loft_insulation": -2780, "impact_of_cavity_insulation": -4136, "space_heating_existing_dwelling": 17203}, "energy_consumption_current": 677, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 85, "calculation_software_version": "1.0.x", "energy_consumption_potential": 400, "environmental_impact_current": 20, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "G", "environmental_impact_potential": 41, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "F", "co2_emissions_current_per_floor_area": 118, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 207082033, "roofs": [{"description": {"value": "Pitched, 0 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "N14 7DG", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-10-15 10:27:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 646}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "74, Selborne Road", "assessment_type": "RdSAP", "completion_date": "2017-10-15", "inspection_date": "2017-10-12", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 145, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, smokeless fuel", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.49, "quantity": "square metres"}, "party_wall_length": {"value": 10.05, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 65.49, "quantity": "square metres"}, "party_wall_length": {"value": 10.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.738, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.59, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.738, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.23, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 3.23, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 4.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 1, "roof_construction": 1, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 0.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 1.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2158, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 13.9, "energy_rating_average": 60, "energy_rating_current": 27, "lighting_cost_current": {"value": 131, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 705, "currency": "GBP"}, "hot_water_cost_current": {"value": 249, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 5, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 333, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 24}, {"sequence": 2, "typical_saving": {"value": 590, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 37}, {"sequence": 3, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 39}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 42}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 42}, {"sequence": 6, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 45}, {"sequence": 7, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 47}, {"sequence": 8, "typical_saving": {"value": 245, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 56}, {"sequence": 9, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 58}, {"sequence": 10, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 64}, {"sequence": 11, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 148, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 148, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 432, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3477, "impact_of_loft_insulation": -4826, "impact_of_solid_wall_insulation": -7838, "space_heating_existing_dwelling": 26723}, "energy_consumption_current": 473, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 5, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 105, "environmental_impact_current": 17, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "F", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 96, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100020187915, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DA17 5NG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BELVEDERE", "built_form": 2, "created_at": "2017-10-25 22:07:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Barnfield Road", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 39.84, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 898, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 392, "currency": "GBP"}, "hot_water_cost_current": {"value": 188, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 352, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 156, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2817, "impact_of_solid_wall_insulation": -5678, "space_heating_existing_dwelling": 12663}, "energy_consumption_current": 383, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 77, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 3455050720, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "ST6 5AY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2017-10-06 12:36:46.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Holland Street", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 29.52, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.73, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 936, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 465, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a385", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 6, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 10, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 182, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2587, "impact_of_loft_insulation": -78, "impact_of_cavity_insulation": -534, "impact_of_solid_wall_insulation": -2172, "space_heating_existing_dwelling": 12282}, "energy_consumption_current": 456, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 22108855, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN2 6SP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIGHTON", "built_form": 1, "created_at": "2017-10-17 22:11:01.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9157}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "15, Crescent Drive North", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.32, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 485, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2259, "impact_of_loft_insulation": -415, "space_heating_existing_dwelling": 8894}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 83, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061738818, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 59% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO19 3JF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHICHESTER", "built_form": 1, "created_at": "2017-10-11 15:22:31.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "17, Clay Lane", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-05", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 68.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.91, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.84, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 59, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 654, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 491, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2893, "impact_of_cavity_insulation": -894, "space_heating_existing_dwelling": 11365}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 95, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 45070542, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE37 3EN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 4, "created_at": "2017-10-07 09:02:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9158}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "130, Waterloo Walk", "assessment_type": "RdSAP", "completion_date": "2017-10-07", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 32, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-10-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 277, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 192, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 82}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 83}], "co2_emissions_potential": 0.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 25, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 10, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1442, "impact_of_cavity_insulation": -975, "space_heating_existing_dwelling": 2830}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 169, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100040345209, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ14 8BL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TEIGNMOUTH", "built_form": 2, "created_at": "2017-10-12 16:06:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17610}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "12, Powderham Terrace", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.39, "quantity": "metres"}}, "total_floor_area": 29, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 500, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.3574, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 28.69, "quantity": "square metres"}, "party_wall_length": {"value": 1.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 415, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 23, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 204, "currency": "GBP"}, "hot_water_cost_current": {"value": 66, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 23, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1389, "impact_of_loft_insulation": -2276, "impact_of_solid_wall_insulation": -2228, "space_heating_existing_dwelling": 6391}, "energy_consumption_current": 403, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 190, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10001026517, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK45 4FB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 4, "created_at": "2017-10-25 13:55:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1821}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Shortcroft Court", "address_line_2": "Barton-le-Clay", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.4, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 28.4, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 0.0126, "quantity": "square metres"}, "party_wall_length": {"value": 1.4, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 2.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 376, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 346, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1809, "impact_of_loft_insulation": -328, "space_heating_existing_dwelling": 5065}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 74, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 5870037885, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 8% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SM1 4DG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SUTTON", "built_form": 4, "created_at": "2017-10-26 15:06:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 260}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Flat 41 Homedale House", "address_line_2": "3, Brunswick Road", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-26", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 165, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.325, "quantity": "metres"}, "total_floor_area": {"value": 37.851, "quantity": "square metres"}, "party_wall_length": {"value": 19.694, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.07, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 29.838, "quantity": "square metres"}, "party_wall_length": {"value": 10.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 165, "floor_heat_loss": 1, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.325, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.486, "quantity": "square metres"}, "party_wall_length": {"value": 3.12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 8.486, "quantity": "square metres"}, "party_wall_length": {"value": 3.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 160, "floor_heat_loss": 1, "roof_construction": 1, "wall_construction": 8, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.08, "quantity": "square metres"}, "party_wall_length": {"value": 1.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 654, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 120, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 528, "currency": "GBP"}, "hot_water_cost_current": {"value": 192, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.1, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 228, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 118, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2863, "space_heating_existing_dwelling": 8786}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 197, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100110109129, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS1 5LN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLESBROUGH", "built_form": 2, "created_at": "2017-10-06 17:31:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "53, Eshwood Square", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 55.49, "quantity": "square metres"}, "party_wall_length": {"value": 4.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.94, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 456, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.1, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1788, "space_heating_existing_dwelling": 6136}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 213, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200001763075, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SE9 6TY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-10-15 20:06:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "391a, Well Hall Road", "assessment_type": "RdSAP", "completion_date": "2017-10-15", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 5, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 198, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 201, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1808, "space_heating_existing_dwelling": 1817}, "energy_consumption_current": 142, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 133, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100110036185, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TS26 8BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARTLEPOOL", "built_form": 2, "created_at": "2017-08-01 14:30:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Young Street", "assessment_type": "RdSAP", "completion_date": "2017-08-01", "inspection_date": "2017-06-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.4, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.4, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1, "quantity": "square metres"}, "party_wall_length": {"value": 1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 421, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 394, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1856, "impact_of_loft_insulation": -6, "space_heating_existing_dwelling": 6561}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 103, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200000638570, "roofs": [{"description": {"value": "Pitched, 400 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO42 4RW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 1, "created_at": "2017-04-18 08:25:07.000000", "door_count": 1, "glazed_area": 2, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Wensley House", "address_line_2": "Allerthorpe", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 160, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 37.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 75, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 40.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.22, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1078, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 989, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 84}], "co2_emissions_potential": 2.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 102, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3318, "impact_of_loft_insulation": -78, "space_heating_existing_dwelling": 18372}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 88, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 24, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 72312239, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS18 5LN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 2, "created_at": "2017-08-15 11:12:20.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Hall Park Avenue", "address_line_2": "Horsforth", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 36.5, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "250mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 631, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 180, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2200, "space_heating_existing_dwelling": 9100}, "energy_consumption_current": 253, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 86, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10003880596, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP3 8BW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IPSWICH", "built_form": 1, "created_at": "2017-08-15 15:14:14.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Foxley Close", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.13, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 57.12, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.03, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.71, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 503, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 510, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2556, "space_heating_existing_dwelling": 8890}, "energy_consumption_current": 137, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 78, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100031649676, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DE15 0LQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BURTON-ON-TRENT", "built_form": 1, "created_at": "2017-09-18 13:34:37.000000", "door_count": 2, "glazed_area": 4, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "sap_windows": [{"orientation": 1, "window_area": {"value": 6.08, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 3, "window_area": {"value": 3.49, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 7, "window_area": {"value": 2.16, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 2}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 5, "window_area": {"value": 6.07, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 5, "window_area": {"value": 0.81, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 2}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "137, Ashby Road", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-15", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.54, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.81, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1967, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12, "energy_rating_average": 60, "energy_rating_current": 25, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 751, "currency": "GBP"}, "hot_water_cost_current": {"value": 318, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 369, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 28}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 30}, {"sequence": 3, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 34}, {"sequence": 4, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 35}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 37}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 37}, {"sequence": 7, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 45}, {"sequence": 8, "typical_saving": {"value": 411, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 9, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 10, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 35, "environmental_impact_rating": 29}, {"sequence": 2, "typical_saving": {"value": 223, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 88}, {"sequence": 3, "typical_saving": {"value": 147, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 530, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3620, "impact_of_loft_insulation": -1268, "impact_of_cavity_insulation": -4658, "impact_of_solid_wall_insulation": -1656, "space_heating_existing_dwelling": 22406}, "energy_consumption_current": 628, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 164, "environmental_impact_current": 20, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "F", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 111, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080515066, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HP5 1PY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHESHAM", "built_form": 4, "created_at": "2017-05-16 08:18:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "286, Waterside", "assessment_type": "RdSAP", "completion_date": "2017-05-16", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2017-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.5, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 24.1, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 660, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 323, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 135, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2433, "impact_of_loft_insulation": -191, "impact_of_solid_wall_insulation": -3064, "space_heating_existing_dwelling": 7922}, "energy_consumption_current": 399, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 66, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040294324, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 11% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PL8 2AP", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PLYMOUTH", "built_form": 1, "created_at": "2017-08-16 09:19:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "7, The Crescent", "address_line_2": "Brixton", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 84.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 537, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 393, "currency": "GBP"}, "hot_water_cost_current": {"value": 381, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5111, "space_heating_existing_dwelling": 6382}, "energy_consumption_current": 357, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 77, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 72761153, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LS11 7EJ", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 4, "created_at": "2017-09-16 12:05:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "103 Wickham Street", "assessment_type": "RdSAP", "completion_date": "2017-09-16", "inspection_date": "2017-09-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.8, "quantity": "metres"}}, "total_floor_area": 32, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-09-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.5, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 31.5, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 299, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 223, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.3, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 25, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1691, "impact_of_solid_wall_insulation": -1158, "space_heating_existing_dwelling": 3101}, "energy_consumption_current": 310, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 233, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10002500663, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN37 7RX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. LEONARDS-ON-SEA", "built_form": 2, "created_at": "2017-09-28 17:21:34.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Knowsley Court", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 357, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 359, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2502, "space_heating_existing_dwelling": 5336}, "energy_consumption_current": 149, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 62, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 310006964, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG2 7UB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 4, "created_at": "2017-10-19 15:50:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15032}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "126 Denton Court", "address_line_2": "Hexham Road", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-19", "extensions_count": 3, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.79}, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 190, "floor_heat_loss": 6, "roof_construction": 7, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.3044, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 230, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 19.32, "quantity": "square metres"}, "party_wall_length": {"value": 8.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 50, "floor_heat_loss": 8, "roof_construction": 5, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 18.47, "quantity": "square metres"}, "party_wall_length": {"value": 7.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 50, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 8, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 20.61, "quantity": "square metres"}, "party_wall_length": {"value": 8.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 50, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 8, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.67, "quantity": "square metres"}, "party_wall_length": {"value": 3.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 525, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 528, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}], "co2_emissions_potential": 3.1, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2682, "impact_of_loft_insulation": -4153, "impact_of_solid_wall_insulation": -375, "space_heating_existing_dwelling": 9051}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 266, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 44059458, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ME5 8YX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHATHAM", "built_form": 1, "created_at": "2017-10-02 16:57:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "24, Merton Close", "assessment_type": "RdSAP", "completion_date": "2017-10-02", "inspection_date": "2017-10-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.95, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 32.95, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 764, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 527, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2776, "impact_of_loft_insulation": -2141, "impact_of_cavity_insulation": -4540, "space_heating_existing_dwelling": 14270}, "energy_consumption_current": 333, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 134, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100418641, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 27% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LL28 5YL", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "COLWYN BAY", "built_form": 1, "created_at": "2017-10-27 14:26:59.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "148, Llanrwst Road", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 183, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 95.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 40.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 8, "sap_room_in_roof": {"floor_area": 31.8, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 25.31, "wall_dry_lined": "N", "wall_thickness": 330, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 54.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 36.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1718, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 158, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1234, "currency": "GBP"}, "hot_water_cost_current": {"value": 265, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 80, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 526, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 65}], "co2_emissions_potential": 6.0, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 198, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 722, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 124, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3688, "impact_of_loft_insulation": -2013, "space_heating_existing_dwelling": 22684}, "energy_consumption_current": 324, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 184, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "E", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10000153284, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE26 2NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUNTINGDON", "built_form": 2, "created_at": "2017-05-15 10:38:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15170}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Hill Estate", "address_line_2": "Bury, Ramsey", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 9.07, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 8.45, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.01, "quantity": "square metres"}, "party_wall_length": {"value": 4.55, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 44.01, "quantity": "square metres"}, "party_wall_length": {"value": 4.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.65, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 962, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 564, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2239, "impact_of_loft_insulation": -263, "impact_of_solid_wall_insulation": -6814, "space_heating_existing_dwelling": 17687}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 114, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100110500804, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS21 2DY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKTON-ON-TEES", "built_form": 3, "created_at": "2017-07-15 08:37:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "9, Wykes Close", "address_line_2": "Sedgefield", "assessment_type": "RdSAP", "completion_date": "2017-07-15", "inspection_date": "2017-07-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 25.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 443, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2021, "space_heating_existing_dwelling": 7209}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10033392599, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B23 5GG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-08-22 13:18:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16892}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6 Wendover Road", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.37, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 32.37, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 394, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 401, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2365, "impact_of_loft_insulation": -224, "space_heating_existing_dwelling": 6092}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 108, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 36005792, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LA14 2QR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARROW-IN-FURNESS", "built_form": 3, "created_at": "2017-09-22 13:53:14.000000", "door_count": 2, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8463}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "39, Aberdeen Street", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.8, "quantity": "square metres"}, "party_wall_length": {"value": 10.99, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 28.8, "quantity": "square metres"}, "party_wall_length": {"value": 10.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 558, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 389, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 44, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1822, "impact_of_loft_insulation": -162, "impact_of_cavity_insulation": -2218, "space_heating_existing_dwelling": 8602}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 86, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031783926, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ST17 4DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 3, "created_at": "2017-06-15 15:17:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Talbot Road", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-15", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 139, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 30.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 34.98, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.43, "quantity": "square metres"}, "party_wall_length": 8.13, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1659, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.9, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 779, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 87, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 721, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1713, "impact_of_solid_wall_insulation": -13736, "space_heating_existing_dwelling": 29388}, "energy_consumption_current": 361, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 131, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100100991891, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SA12 9NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PORT TALBOT", "built_form": 2, "created_at": "2017-09-15 17:03:16.000000", "door_count": 4, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10122}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Heol Crwys", "address_line_2": "Cwmavon", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-15", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 152, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 316, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.75, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 35.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 7.56, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 322, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.97, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 32.97, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 17.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 752, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 716, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 94, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2320, "impact_of_loft_insulation": -248, "space_heating_existing_dwelling": 10994}, "energy_consumption_current": 155, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100110470322, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DL17 8AT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FERRYHILL", "built_form": 4, "created_at": "2017-04-18 07:32:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Conyers Terrace", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-15", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.2, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 32.2, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.81, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 908, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 807, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.9, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2008, "impact_of_loft_insulation": -3542, "impact_of_solid_wall_insulation": -1408, "space_heating_existing_dwelling": 13474}, "energy_consumption_current": 366, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 236, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100062120403, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "KT10 8BF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ESHER", "built_form": 2, "created_at": "2017-09-28 17:46:18.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "17a, Farm Road", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 4.0}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 254, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 248, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1546, "space_heating_existing_dwelling": 2472}, "energy_consumption_current": 196, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 182, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10013915366, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ME19 4GA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEST MALLING", "built_form": 2, "created_at": "2017-08-15 14:00:45.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15462}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "80, Discovery Drive", "address_line_2": "Kings Hill", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.83, "quantity": "square metres"}, "party_wall_length": {"value": 8.07, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 40.83, "quantity": "square metres"}, "party_wall_length": {"value": 8.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 329, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 337, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2356, "space_heating_existing_dwelling": 4677}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 52, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070957247, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B37 6JN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2017-08-15 17:49:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17430}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "54, Dunton Road", "address_line_2": "Kingshurst", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 105, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.58, "quantity": "square metres"}, "party_wall_length": {"value": 15, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 52.58, "quantity": "square metres"}, "party_wall_length": {"value": 15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.02, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 511, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 483, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1945, "space_heating_existing_dwelling": 8644}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 86, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100020485903, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 7% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BR4 9DF", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WEST WICKHAM", "built_form": 2, "created_at": "2017-06-16 15:21:29.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "107, Gates Green Road", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-15", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 141, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.62, "quantity": "square metres"}, "party_wall_length": {"value": 7.72, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 58.63, "quantity": "square metres"}, "party_wall_length": {"value": 7.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 7, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1461, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.1, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 151, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 730, "currency": "GBP"}, "hot_water_cost_current": {"value": 300, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 550, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 8, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 9, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5340, "impact_of_loft_insulation": -531, "impact_of_solid_wall_insulation": -9682, "space_heating_existing_dwelling": 23923}, "energy_consumption_current": 365, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.11r11", "energy_consumption_potential": 120, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 34040774, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW6 3UQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-05-15 14:55:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16841}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 51 Ranelagh Gardens Mansions", "address_line_2": "Ranelagh Gardens", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 62.48, "quantity": "square metres"}, "party_wall_length": {"value": 17.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 546, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": "Room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 474, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.5, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1676, "impact_of_loft_insulation": -5395, "impact_of_solid_wall_insulation": -1418, "space_heating_existing_dwelling": 9214}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["Y"], "calculation_software_version": "2.11r11", "energy_consumption_potential": 226, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200003709334, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 76% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME5 9JD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHATHAM", "built_form": 1, "created_at": "2017-10-21 16:07:05.000000", "door_count": 8, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Carne Brae", "address_line_2": "Boxley Road", "assessment_type": "RdSAP", "completion_date": "2017-10-21", "inspection_date": "2017-10-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 212, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-10-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 170, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 83.12, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 105.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 43.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.76, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 76, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1359, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1193, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 76}], "co2_emissions_potential": 4.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 122, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2879, "space_heating_existing_dwelling": 21580}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 98, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 71, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 54} +{"uprn": 10012066894, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT12 4BF", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALTON-ON-THAMES", "built_form": 4, "created_at": "2017-10-16 17:08:26.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2303, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 25 Huntley House", "address_line_2": "Octagon Road", "address_line_3": "Whiteley Village, Hersham", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.87, "quantity": "metres"}, "total_floor_area": {"value": 41.85, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 189, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 171, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1790, "impact_of_loft_insulation": -306, "space_heating_existing_dwelling": 1731}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 154, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100021232191, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "N8 9EY", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-10 22:40:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "18 Tregaron Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.97, "quantity": "metres"}}, "total_floor_area": 18, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.7587, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.9, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 308, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 137, "currency": "GBP"}, "hot_water_cost_current": {"value": 211, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 83}], "co2_emissions_potential": 0.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 18, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 171, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 165, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1342, "impact_of_solid_wall_insulation": -744, "space_heating_existing_dwelling": 1961}, "energy_consumption_current": 605, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 244, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 2, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 102, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 12070781, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W7 2JN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-12 14:33:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50, Elthorne Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 124, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 25, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.4, "quantity": "square metres"}, "party_wall_length": {"value": 18.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 49.4, "quantity": "square metres"}, "party_wall_length": {"value": 18.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1352, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 647, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 241, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 200, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2295, "impact_of_loft_insulation": -1758, "impact_of_solid_wall_insulation": -3926, "space_heating_existing_dwelling": 21547}, "energy_consumption_current": 349, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 119, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100031204052, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NN8 4EN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLINGBOROUGH", "built_form": 4, "created_at": "2017-10-18 08:12:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17548}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "16, Lister Road", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.24, "quantity": "square metres"}, "party_wall_length": {"value": 13.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 29.24, "quantity": "square metres"}, "party_wall_length": {"value": 13.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.14, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.6, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 9.6, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 651, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 446, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 212, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2796, "impact_of_solid_wall_insulation": -3760, "space_heating_existing_dwelling": 9440}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 90, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100031707316, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WS15 4HF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUGELEY", "built_form": 4, "created_at": "2017-10-15 09:01:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Harvey Road", "assessment_type": "RdSAP", "completion_date": "2017-10-15", "inspection_date": "2017-10-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.65, "quantity": "square metres"}, "party_wall_length": {"value": 12.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 43.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 864, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 503, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 187, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2174, "impact_of_loft_insulation": -776, "impact_of_cavity_insulation": -2997, "space_heating_existing_dwelling": 11919}, "energy_consumption_current": 287, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 101, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 452043366, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TF1 3QU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "TELFORD", "built_form": 4, "created_at": "2017-10-05 15:20:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16511}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Round Oak Drive", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 304, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.55, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 31.75, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 488, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 418, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2518, "impact_of_loft_insulation": -210, "space_heating_existing_dwelling": 6217}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100050466415, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "YO12 6EZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SCARBOROUGH", "built_form": 2, "created_at": "2017-10-05 21:02:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9897}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "183, Barrowcliff Road", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 34.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 7.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 624, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 602, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2836, "space_heating_existing_dwelling": 8962}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 136, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100050709757, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 13% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "DN5 9PG", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "DONCASTER", "built_form": 2, "created_at": "2017-10-11 19:48:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "5, Chiltern Road", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.11, "quantity": "square metres"}, "party_wall_length": {"value": 6.51, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 42.11, "quantity": "square metres"}, "party_wall_length": {"value": 6.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 888, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 489, "currency": "GBP"}, "hot_water_cost_current": {"value": 255, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 197, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3514, "impact_of_loft_insulation": -237, "impact_of_cavity_insulation": -3658, "space_heating_existing_dwelling": 11363}, "energy_consumption_current": 395, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 116, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10022962620, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CT9 4BP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARGATE", "built_form": 3, "created_at": "2017-08-17 02:11:28.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "60, Wherry Close", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 59.23, "quantity": "square metres"}, "party_wall_length": {"value": 8.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 254, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 257, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1882, "space_heating_existing_dwelling": 3045}, "energy_consumption_current": 145, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 139, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100091394258, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP17 2HD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "SAXMUNDHAM", "built_form": 1, "created_at": "2017-10-17 12:45:20.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2207, "main_heating_category": 4, "main_heating_fraction": 1, "sap_main_heating_code": 224, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Air source heat pump, underfloor, electric", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "The Cabin", "address_line_2": "Apple Tree Farm", "address_line_3": "Peasenhall", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 50, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 2, "peak_power": 4, "orientation": 5, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9, 11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 294, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": -0.3, "energy_rating_average": 60, "energy_rating_current": 101, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 295, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 104, "environmental_impact_rating": 104}, {"sequence": 2, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 133, "environmental_impact_rating": 130}], "co2_emissions_potential": -2.4, "energy_rating_potential": 133, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1936, "space_heating_existing_dwelling": 2980}, "energy_consumption_current": -39, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": -287, "environmental_impact_current": 101, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "A", "environmental_impact_potential": 130, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": -7, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 14053058, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RG40 1QW", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WOKINGHAM", "built_form": 3, "created_at": "2017-08-17 08:29:16.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 109, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "39, Longs Way", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 58, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 58.06, "quantity": "square metres"}, "party_wall_length": {"value": 7.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 275, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 252, "currency": "GBP"}, "hot_water_cost_current": {"value": 234, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 107, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3084, "space_heating_existing_dwelling": 2397}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 148, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10000802667, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SG5 4QB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HITCHIN", "built_form": 1, "created_at": "2017-10-16 14:19:41.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 2040}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Heron Way", "address_line_2": "Stotfold", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 39.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 7.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 539, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 474, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2734, "impact_of_loft_insulation": -325, "space_heating_existing_dwelling": 8382}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 99, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100081250814, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SG14 1RZ", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HERTFORD", "built_form": 4, "created_at": "2017-06-20 09:32:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15018}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "17, St. Johns Court", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-06-16", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 2.45}, "total_floor_area": 54, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 12.52, "quantity": "square metres"}, "party_wall_length": {"value": 11.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 170, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 5.733, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 170, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 34.74, "quantity": "square metres"}, "party_wall_length": {"value": 1.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 170, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 7.01, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 385, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 299, "currency": "GBP"}, "hot_water_cost_current": {"value": 172, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3230, "impact_of_loft_insulation": -726, "impact_of_solid_wall_insulation": -304, "space_heating_existing_dwelling": 5420}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.11r11", "energy_consumption_potential": 185, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 90055178, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DY1 4BS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "DUDLEY", "built_form": 2, "created_at": "2017-08-16 16:26:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Beech Road", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.47, "quantity": "square metres"}, "party_wall_length": {"value": 6.74, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 37.47, "quantity": "square metres"}, "party_wall_length": {"value": 6.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 967, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 416, "currency": "GBP"}, "hot_water_cost_current": {"value": 250, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 399, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 9, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3444, "impact_of_solid_wall_insulation": -5697, "space_heating_existing_dwelling": 12151}, "energy_consumption_current": 472, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 95, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060121782, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN27 3AZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HAILSHAM", "built_form": 2, "created_at": "2017-06-16 17:30:41.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5928}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "52, Stroma Gardens", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 33.33, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "100mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.47, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.65, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 523, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 310, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 6, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2734, "impact_of_loft_insulation": -44, "space_heating_existing_dwelling": 7476}, "energy_consumption_current": 256, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 43, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200001004849, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "GU17 0JQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBERLEY", "built_form": 3, "created_at": "2017-06-16 14:30:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10265}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Tichborne Close", "address_line_2": "Blackwater", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-16", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.18, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.18, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.32, "quantity": "square metres"}, "party_wall_length": 3.2, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 652, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 554, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2212, "space_heating_existing_dwelling": 10243}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 113, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 50040966, "roofs": [{"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CT20 1EW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FOLKESTONE", "built_form": 4, "created_at": "2017-05-16 19:25:28.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "15, Coolinge Road", "assessment_type": "RdSAP", "completion_date": "2017-05-16", "inspection_date": "2017-05-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 150, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 35.36, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.44, "quantity": "square metres"}, "party_wall_length": {"value": 15.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 37.01, "quantity": "square metres"}, "party_wall_length": {"value": 14.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.18, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 37.01, "quantity": "square metres"}, "party_wall_length": {"value": 14.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.5, "quantity": "square metres"}, "party_wall_length": {"value": 1.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 1.5, "quantity": "square metres"}, "party_wall_length": {"value": 1.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1510, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 723, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 377, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2319, "impact_of_loft_insulation": -164, "impact_of_solid_wall_insulation": -4554, "space_heating_existing_dwelling": 28038}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 113, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 77201855, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M8 5EA", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 2, "created_at": "2017-05-23 15:35:29.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 7", "address_line_2": "41 Rectory Road", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.52, "quantity": "square metres"}, "party_wall_length": {"value": 14.13, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 228, "currency": "GBP"}, "hot_water_cost_current": {"value": 318, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 206, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 251, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 234, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 83}, {"sequence": 3, "typical_saving": {"value": 154, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2045, "impact_of_solid_wall_insulation": -2416, "space_heating_existing_dwelling": 5716}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 152, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100051356686, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "OL14 6BA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TODMORDEN", "built_form": 1, "created_at": "2017-06-18 19:05:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "33, Dale Avenue", "assessment_type": "RdSAP", "completion_date": "2017-06-18", "inspection_date": "2017-06-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-06-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.73, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 50.73, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.81, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 877, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 141, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 814, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 246, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2286, "space_heating_existing_dwelling": 13726}, "energy_consumption_current": 245, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 167, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060734059, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO19 8FH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 2, "created_at": "2017-05-16 21:50:20.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, St. Monica Road", "assessment_type": "RdSAP", "completion_date": "2017-05-16", "inspection_date": "2017-05-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.61, "quantity": "square metres"}, "party_wall_length": {"value": 8.13, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 30.16, "quantity": "square metres"}, "party_wall_length": {"value": 8.13, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.88, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.89, "quantity": "square metres"}, "party_wall_length": {"value": 4.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 10.89, "quantity": "square metres"}, "party_wall_length": {"value": 4.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.75, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 443, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 416, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2091, "space_heating_existing_dwelling": 6832}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 74, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 338347, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS2 8DB", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2017-10-24 16:27:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "The Production House", "address_line_3": "147a St. Micheals Hill", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 9.76}, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 24.9856, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 260, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 85.41, "quantity": "square metres"}, "party_wall_length": {"value": 8.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 38.22, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 641, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 306, "currency": "GBP"}, "hot_water_cost_current": {"value": 412, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 407, "currency": "GBP"}, "indicative_cost": "4,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 64}], "co2_emissions_potential": 3.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 522, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 471, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 150, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2624, "impact_of_solid_wall_insulation": -672, "space_heating_existing_dwelling": 4082}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 211, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021571037, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TW7 6JF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ISLEWORTH", "built_form": 2, "created_at": "2017-10-23 11:57:08.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "84a, Morris Road", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 56, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 56.34, "quantity": "square metres"}, "party_wall_length": {"value": 6.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 234, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1905, "impact_of_loft_insulation": -517, "impact_of_solid_wall_insulation": -3613, "space_heating_existing_dwelling": 6630}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 136, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 74013029, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S41 0RX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTERFIELD", "built_form": 2, "created_at": "2017-07-13 15:03:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "11, Dickenson Road", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-13", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.09, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.55, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.1, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 467, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 388, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1832, "space_heating_existing_dwelling": 6209}, "energy_consumption_current": 338, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 127, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100110295495, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 77% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CA3 9HU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CARLISLE", "built_form": 4, "created_at": "2017-07-13 17:01:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 118, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 635, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Rosebery Road", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 114, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 22.3, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "H", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.7, "quantity": "square metres"}, "party_wall_length": {"value": 14.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.2, "quantity": "metres"}, "total_floor_area": {"value": 45.7, "quantity": "square metres"}, "party_wall_length": {"value": 14.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 77, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 774, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 423, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 238, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 145, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 311, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2278, "impact_of_loft_insulation": -1950, "impact_of_solid_wall_insulation": -6397, "space_heating_existing_dwelling": 20244}, "energy_consumption_current": 407, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 156, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100120754422, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DY10 1LN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "KIDDERMINSTER", "built_form": 5, "created_at": "2017-05-13 11:44:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 37 Courtney", "address_line_2": "St. Cecilia Close", "assessment_type": "RdSAP", "completion_date": "2017-05-13", "inspection_date": "2017-05-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 6, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-05-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 68.25, "quantity": "square metres"}, "party_wall_length": {"value": 15.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 177, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 145, "currency": "GBP"}, "hot_water_cost_current": {"value": 277, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 145, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 163, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 168, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2027, "space_heating_existing_dwelling": 1950}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 181, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100121142926, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN5 8HJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 2, "created_at": "2017-05-15 21:28:05.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8625}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, Luddesdown Road", "address_line_2": "Toothill", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-13", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 29.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 11.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 718, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 560, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2248, "impact_of_loft_insulation": -141, "space_heating_existing_dwelling": 10568}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 30, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100010714049, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PR3 1FS", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "PRESTON", "built_form": 2, "created_at": "2017-10-13 13:59:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "6, Beech Road", "address_line_2": "Garstang", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 313, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.3, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 26.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 784, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 419, "currency": "GBP"}, "hot_water_cost_current": {"value": 276, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 417, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 293, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 254, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 418, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2008, "space_heating_existing_dwelling": 9153}, "energy_consumption_current": 530, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 111, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 90, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100110142114, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS5 6DU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLESBROUGH", "built_form": 4, "created_at": "2017-10-13 18:16:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16145}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "20, Ventnor Road", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.84, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 44.84, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 796, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 613, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2231, "impact_of_cavity_insulation": -644, "impact_of_solid_wall_insulation": -2293, "space_heating_existing_dwelling": 13277}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 135, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 38146124, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L4 2QA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2017-10-16 08:18:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Stonehill Street", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.2, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 25.2, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 555, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 422, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1828, "impact_of_cavity_insulation": -600, "impact_of_solid_wall_insulation": -1478, "space_heating_existing_dwelling": 8513}, "energy_consumption_current": 297, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100100505552, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CF32 9PY", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BRIDGEND", "built_form": 4, "created_at": "2017-10-13 16:01:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 103}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, St. Brides Road", "address_line_2": "Aberkenfig", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 13, "conservatory_type": 4, "heated_room_count": 3, "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 6.15, "quantity": "square metres"}, "room_height": 1, "double_glazed": "N", "glazed_perimeter": {"value": 4.96, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.93, "quantity": "square metres"}, "party_wall_length": {"value": 13.24, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 33.89, "quantity": "square metres"}, "party_wall_length": {"value": 13.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.58, "quantity": "square metres"}, "party_wall_length": {"value": 1.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1077, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 605, "currency": "GBP"}, "hot_water_cost_current": {"value": 226, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 56, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 6, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 7, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 8, "typical_saving": {"value": 180, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 9, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 10, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 11, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 115, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 305, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3123, "impact_of_loft_insulation": -409, "impact_of_cavity_insulation": -590, "impact_of_solid_wall_insulation": -1973, "space_heating_existing_dwelling": 12719}, "energy_consumption_current": 417, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 62, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100110065315, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TS10 1PN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "REDCAR", "built_form": 2, "created_at": "2017-09-18 00:17:20.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "30, Forth Road", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-13", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.84, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 40.57, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 914, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 685, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2218, "impact_of_loft_insulation": -379, "impact_of_cavity_insulation": -3822, "space_heating_existing_dwelling": 15207}, "energy_consumption_current": 309, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 160, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 37027656, "roofs": [{"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO12 2RA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GOSPORT", "built_form": 2, "created_at": "2017-04-13 17:54:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8788}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, Oval Gardens", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-13", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 167, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 45.24, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.01, "quantity": "square metres"}, "party_wall_length": {"value": 8.91, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.07, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 57.91, "quantity": "square metres"}, "party_wall_length": {"value": 8.91, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.31, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1312, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 124, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 940, "currency": "GBP"}, "hot_water_cost_current": {"value": 158, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.6, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2856, "impact_of_loft_insulation": -568, "impact_of_cavity_insulation": -2788, "space_heating_existing_dwelling": 19013}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 91, "calculation_software_version": "2.11r09", "energy_consumption_potential": 120, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 45145237, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR3 4JZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 03:58:21.000000", "door_count": 3, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "33, Thanet Road", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-02-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 43, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 642, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 592, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2158, "space_heating_existing_dwelling": 9091}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 127, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 3040065866, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 18% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NG2 5HG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2017-10-13 14:16:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10316}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Apartment 6 Regency Point", "address_line_2": "Radcliffe Road", "address_line_3": "West Bridgford", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 4.8}, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.56, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 83.8, "quantity": "square metres"}, "party_wall_length": {"value": 15.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 404, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 1, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2142, "space_heating_existing_dwelling": 2450}, "energy_consumption_current": 151, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 142, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 83189492, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HD2 1NY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 2, "created_at": "2017-09-13 19:18:33.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Catherine Road", "assessment_type": "RdSAP", "completion_date": "2017-09-13", "inspection_date": "2017-09-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.6, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 43.4, "quantity": "square metres"}, "party_wall_length": {"value": 8.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.71, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 426, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 124, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 434, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "space_heating_existing_dwelling": 6813}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 41093828, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 87% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L31 3HD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2017-07-16 11:54:11.000000", "door_count": 0, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 16454}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Tailors Lane", "assessment_type": "RdSAP", "completion_date": "2017-07-16", "inspection_date": "2017-07-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-07-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.42, "quantity": "square metres"}, "party_wall_length": {"value": 7.64, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 46.65, "quantity": "square metres"}, "party_wall_length": {"value": 7.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.98, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 87, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 783, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 539, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 159, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2919, "impact_of_loft_insulation": -642, "impact_of_cavity_insulation": -3550, "impact_of_solid_wall_insulation": -1243, "space_heating_existing_dwelling": 14928}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 115, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 74041383, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S40 3LD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTERFIELD", "built_form": 1, "created_at": "2017-09-14 18:25:20.000000", "door_count": 4, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16138}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "45, Somersall Park Road", "assessment_type": "RdSAP", "completion_date": "2017-09-14", "inspection_date": "2017-09-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 177, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 10, "pvc_window_frames": "false", "registration_date": "2017-09-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 32.48, "quantity": "square metres"}, "insulation": 6, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "100mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.99, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 54.99, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 11, "heating_cost_current": {"value": 1378, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 140, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1143, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3100", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "co2_emissions_potential": 4.9, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2223, "impact_of_loft_insulation": -273, "space_heating_existing_dwelling": 22239}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 157, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 35, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100022549742, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E11 1EQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-05-15 10:52:46.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17732}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "54 Hainault Road", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1, "quantity": "metres"}}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.48, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 68.59, "quantity": "square metres"}, "party_wall_length": {"value": 16.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 489, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1588, "impact_of_loft_insulation": -617, "impact_of_solid_wall_insulation": -4322, "space_heating_existing_dwelling": 8019}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 113, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100000335983, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "High performance glazing", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE33 2ED", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTH SHIELDS", "built_form": 2, "created_at": "2017-04-04 14:25:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "34, Hedley Close", "assessment_type": "RdSAP", "completion_date": "2017-04-04", "inspection_date": "2017-03-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_u_value": 0.3, "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 45.51, "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.45, "quantity": "square metres"}, "party_wall_length": {"value": 9.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 41.94, "quantity": "square metres"}, "party_wall_length": {"value": 9.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 545, "currency": "GBP"}, "insulated_door_count": 2, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 7, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 511, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "insulated_door_u_value": 1.5, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2146, "impact_of_loft_insulation": -2603, "space_heating_existing_dwelling": 9181}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 114, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 1.5, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100061801892, "roofs": [{"description": {"value": "Pitched, 25 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BN5 9QB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HENFIELD", "built_form": 1, "created_at": "2017-07-13 14:01:20.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "2, Northcroft", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.6}, "total_floor_area": 62, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.28, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 61.66, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 34.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 770, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 273, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1884, "impact_of_loft_insulation": -2147, "impact_of_cavity_insulation": -3214, "impact_of_solid_wall_insulation": -414, "space_heating_existing_dwelling": 10937}, "energy_consumption_current": 405, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 143, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100022576777, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E17 9NQ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 6, "created_at": "2017-06-14 16:49:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 14 Hastingwood Court", "address_line_2": "Pembroke Road", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-05-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.5, "quantity": "metres"}}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.21, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 39.24, "quantity": "square metres"}, "party_wall_length": {"value": 9.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 358, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 101, "currency": "GBP"}, "hot_water_cost_current": {"value": 209, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 33, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 161, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 121, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1560, "impact_of_loft_insulation": -749, "impact_of_cavity_insulation": -251, "impact_of_solid_wall_insulation": -553, "space_heating_existing_dwelling": 4032}, "energy_consumption_current": 458, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 237, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100040280722, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL21 9LG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IVYBRIDGE", "built_form": 2, "created_at": "2017-04-13 12:33:15.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Longbrook Close", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-13", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.52, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 190, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.2, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 43.2, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.69, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 557, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 560, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2309, "impact_of_loft_insulation": -2207, "space_heating_existing_dwelling": 9467}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 123, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 41032389, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "L21 0HN", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2017-08-22 15:15:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "251, Ford Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-22", "inspection_date": "2017-08-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 302, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 254, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4812, "space_heating_existing_dwelling": 3874}, "energy_consumption_current": 316, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 63, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 45133829, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SR1 2LY", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "SUNDERLAND", "built_form": 6, "created_at": "2017-09-13 17:39:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230002, "number_of_heaters": 4, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "27, D'Arcy Court", "assessment_type": "RdSAP", "completion_date": "2017-09-13", "inspection_date": "2017-09-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.37, "quantity": "metres"}}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.614, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 59.12, "quantity": "square metres"}, "party_wall_length": {"value": 7.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.02, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 257, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Controls for high heat retention storage heaters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 149, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 65}], "co2_emissions_potential": 2.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 149, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1713, "space_heating_existing_dwelling": 3055}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 268, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10093587966, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LL18 1PW", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "RHYL", "built_form": 4, "created_at": "2017-07-13 19:03:11.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat B", "address_line_2": "6 John Street", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 51, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 50.9, "quantity": "square metres"}, "party_wall_length": {"value": 19.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 533, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 160, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 188, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 175, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 87}, {"sequence": 3, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1055, "impact_of_solid_wall_insulation": -1992, "space_heating_existing_dwelling": 3394}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100080042638, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK43 8NH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 2, "created_at": "2017-10-17 15:56:04.000000", "door_count": 4, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15020}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "18, Webbs Close", "address_line_2": "Bromham", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-16", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.78, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 39.58, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.76, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 520, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 488, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2750, "space_heating_existing_dwelling": 8857}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 102, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10010443892, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SP1 2EZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SALISBURY", "built_form": 4, "created_at": "2017-09-22 09:54:15.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1113}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "173, The Close", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.09, "quantity": "metres"}}, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.9014, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 330, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 76.21, "quantity": "square metres"}, "party_wall_length": {"value": 8.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 917, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 668, "currency": "GBP"}, "hot_water_cost_current": {"value": 231, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 3, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}], "co2_emissions_potential": 3.8, "energy_rating_potential": 62, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 52, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 331, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 54}], "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3461, "impact_of_loft_insulation": -7406, "impact_of_solid_wall_insulation": -633, "space_heating_existing_dwelling": 13025}, "energy_consumption_current": 425, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 27, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 281, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100062286532, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT14 8BW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DEAL", "built_form": 1, "created_at": "2017-08-18 16:52:05.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10267}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "7, Courtlands", "address_line_2": "Kingsdown Road", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 98.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 42.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 621, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 518, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2229, "space_heating_existing_dwelling": 8940}, "energy_consumption_current": 189, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 86, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 5870000487, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SM2 7NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUTTON", "built_form": 1, "created_at": "2017-07-18 16:00:41", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9909}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Glebe Road", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 150, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 25}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 71.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1619, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.1, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 920, "currency": "GBP"}, "hot_water_cost_current": {"value": 155, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 533, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 198, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2846, "impact_of_loft_insulation": -5864, "impact_of_solid_wall_insulation": -11135, "space_heating_existing_dwelling": 28975}, "energy_consumption_current": 304, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 145, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 22006185, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN41 2HH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIGHTON", "built_form": 2, "created_at": "2017-07-18 17:45:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "133, North Lane", "address_line_2": "Portslade", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 8.76, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 8.9, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 23.26, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.76, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.53, "quantity": "square metres"}, "party_wall_length": 2.93, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 556, "currency": "GBP"}, "insulated_door_count": 1, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 528, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "insulated_door_u_value": 1.8, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 43, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1615, "impact_of_loft_insulation": -264, "space_heating_existing_dwelling": 9045}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 92, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10000156121, "roofs": [{"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE19 5JZ", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ST. NEOTS", "built_form": 1, "created_at": "2017-10-19 09:37:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2031}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "5, Green Lane", "address_line_2": "Hail Weston", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 39.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 12.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 453, "currency": "GBP"}, "hot_water_cost_current": {"value": 323, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 96, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 96, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2055, "impact_of_loft_insulation": -54, "space_heating_existing_dwelling": 10809}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": -7, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100090439169, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO2 9QP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 4, "created_at": "2017-07-19 16:03:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Beechwood Close", "assessment_type": "RdSAP", "completion_date": "2017-07-19", "inspection_date": "2017-07-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 503, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 388, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "impact_of_cavity_insulation": -1628, "space_heating_existing_dwelling": 6838}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 70, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100100897382, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Sandstone or limestone, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 68% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF24 3PD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 3, "created_at": "2017-10-06 15:30:44.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17558}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "17, Wellfield Place", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 128, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.74, "quantity": "square metres"}, "party_wall_length": {"value": 6.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 36.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.48, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 20.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.13, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.14, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 68, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 679, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 642, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2125, "impact_of_loft_insulation": -307, "space_heating_existing_dwelling": 12376}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 114, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 5019301, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW3 2YE", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-23 08:26:39.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.8, "sap_main_heating_code": 408, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.2, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}, {"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Basement flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 Rose Bush Court", "address_line_2": "35, Parkhill Road", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 1}, "total_floor_area": 25, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.04, "quantity": "square metres"}, "party_wall_length": {"value": 15.09, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.93, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 151, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 24, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 137, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 146, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 846, "space_heating_existing_dwelling": 1455}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 282, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100022669957, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW17 0LF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-09-21 08:49:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 770}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "142, Maskell Road", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.82, "quantity": "metres"}}, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.82, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 74.19, "quantity": "square metres"}, "party_wall_length": {"value": 5.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.77, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 347, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 290, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2051, "impact_of_loft_insulation": -895, "space_heating_existing_dwelling": 4014}, "energy_consumption_current": 172, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 132, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 68158108, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "RH6 7JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORLEY", "built_form": 4, "created_at": "2017-09-19 07:16:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16982}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 26 The Quadrangle", "address_line_2": "Lumley Road", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-09-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.54, "quantity": "metres"}}, "total_floor_area": 65, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.3, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 310, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 65.01, "quantity": "square metres"}, "party_wall_length": {"value": 13.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 185, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 190, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1844, "space_heating_existing_dwelling": 1547}, "energy_consumption_current": 110, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 100, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 19, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 25049864, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "MK16 8RN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWPORT PAGNELL", "built_form": 2, "created_at": "2017-04-18 21:28:36.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 607, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "116, Wordsworth Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.05, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 47.69, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.91, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.26, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 717, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 648, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 90, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2261, "impact_of_loft_insulation": -288, "space_heating_existing_dwelling": 11417}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 129, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031856556, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ST11 9PZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2017-08-18 11:12:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "33, Mount Road", "address_line_2": "Blythe Bridge", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.32, "quantity": "square metres"}, "party_wall_length": {"value": 7.19, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 38.32, "quantity": "square metres"}, "party_wall_length": {"value": 7.19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 608, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 441, "currency": "GBP"}, "hot_water_cost_current": {"value": 204, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2780, "space_heating_existing_dwelling": 7383}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 103, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100020228894, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA8 3LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ERITH", "built_form": 2, "created_at": "2017-09-28 17:29:21.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "91, Frinsted Road", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 56, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 892, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 192, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2804, "impact_of_loft_insulation": -4283, "impact_of_cavity_insulation": -3952, "space_heating_existing_dwelling": 16301}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 82, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100022743013, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW1V 3LP", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-05-30 21:18:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2301, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 208 Grenville House", "address_line_2": "Dolphin Square", "assessment_type": "RdSAP", "completion_date": "2017-05-30", "inspection_date": "2017-04-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.86, "quantity": "metres"}}, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-05-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 267, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.465, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 53.12, "quantity": "square metres"}, "party_wall_length": {"value": 16.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 379, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, no thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 212, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 77}}], "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1541, "impact_of_cavity_insulation": -1174, "impact_of_solid_wall_insulation": -283, "space_heating_existing_dwelling": 4625}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 138, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100080772106, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "EN6 1AF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POTTERS BAR", "built_form": 4, "created_at": "2017-05-19 15:48:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "170, Darkes Lane", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-18", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 95, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": {"value": 36.48, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "C"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 56.84, "quantity": "square metres"}, "party_wall_length": {"value": 9.66, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 22.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.88, "quantity": "square metres"}, "party_wall_length": {"value": 9.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 959, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 490, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 373, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2215, "impact_of_cavity_insulation": -1753, "space_heating_existing_dwelling": 17528}, "energy_consumption_current": 321, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 167, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200003865470, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN35 5TA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HASTINGS", "built_form": 3, "created_at": "2017-09-28 17:21:40.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Deepdene Gardens", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 458, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 427, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2594, "impact_of_loft_insulation": -217, "space_heating_existing_dwelling": 7422}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 103, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 11066139, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DN34 4UG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 1, "created_at": "2017-10-18 18:04:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9897}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Augusta Oaks", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 148, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 73.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 36.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 730, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 133, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 744, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 3.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2990, "impact_of_loft_insulation": -480, "space_heating_existing_dwelling": 12928}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 119, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10034815105, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR23 1BL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLS-NEXT-THE-SEA", "built_form": 3, "created_at": "2017-08-18 15:43:04.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8182}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "9, Mindhams Yard", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 15.95, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.85, "quantity": "square metres"}, "party_wall_length": {"value": 3.19, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.23, "quantity": "metres"}, "total_floor_area": {"value": 15.85, "quantity": "square metres"}, "party_wall_length": {"value": 3.19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 888, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 639, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 6, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 8, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 45, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1897, "impact_of_solid_wall_insulation": -2255, "space_heating_existing_dwelling": 12762}, "energy_consumption_current": 444, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 196, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 48013170, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 58% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "KT3 6QQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEW MALDEN", "built_form": 2, "created_at": "2017-10-19 09:58:07", "door_count": 2, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17501}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "46, Cavendish Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 129, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 50}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"floor_area": 17.78, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 11.93}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.38, "quantity": "square metres"}, "party_wall_length": {"value": 8.99, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 53.87, "quantity": "square metres"}, "party_wall_length": {"value": 8.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1152, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 765, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2054, "impact_of_loft_insulation": -997, "impact_of_solid_wall_insulation": -4806, "space_heating_existing_dwelling": 16951}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 114, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 42038210, "roofs": [{"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 93% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH43 4UB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRENTON", "built_form": 3, "created_at": "2017-10-09 19:57:20.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "11, Enfield Terrace", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 158, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 480, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 38.81, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.08, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 39.82, "quantity": "square metres"}, "party_wall_length": {"value": 9.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.85, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.83, "quantity": "metres"}, "total_floor_area": {"value": 39.82, "quantity": "square metres"}, "party_wall_length": {"value": 9.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 93, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2052, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 754, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 354, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 633, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2324, "impact_of_loft_insulation": -68, "impact_of_solid_wall_insulation": -10285, "space_heating_existing_dwelling": 37203}, "energy_consumption_current": 399, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 15, "calculation_software_version": "2.13r09", "energy_consumption_potential": 120, "environmental_impact_current": 32, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100120966334, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX18 2NE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BAMPTON", "built_form": 1, "created_at": "2017-07-12 08:58:24.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 15032}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "The Wychwoods", "address_line_2": "Church View", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 121, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 52.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.39, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1093, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 726, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2819, "impact_of_loft_insulation": -4313, "impact_of_solid_wall_insulation": -6178, "space_heating_existing_dwelling": 21880}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 85, "calculation_software_version": "2.11r11", "energy_consumption_potential": 143, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100031666857, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DE14 3SA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "BURTON-ON-TRENT", "built_form": 2, "created_at": "2017-04-11 16:37:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "119, Ordish Street", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 1.61, "wall_dry_lined": "N", "wall_thickness": 70, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 50.68, "quantity": "square metres"}, "party_wall_length": {"value": 9.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 1.23, "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.6, "quantity": "metres"}, "total_floor_area": {"value": 4.08, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 298, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 304, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.7, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2110, "space_heating_existing_dwelling": 3859}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 174, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100091412609, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB10 2PH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SAFFRON WALDEN", "built_form": 4, "created_at": "2017-05-22 11:09:41", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4 Hills Cottages", "address_line_2": "Hill Road", "address_line_3": "Hempstead", "assessment_type": "RdSAP", "completion_date": "2017-05-22", "inspection_date": "2017-01-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.31, "quantity": "square metres"}, "party_wall_length": {"value": 12.02, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 33.51, "quantity": "square metres"}, "party_wall_length": {"value": 12.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 914, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 687, "currency": "GBP"}, "hot_water_cost_current": {"value": 258, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 597, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 101, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.4, "energy_rating_potential": 101, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 362, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 289, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1879, "impact_of_loft_insulation": -5355, "space_heating_existing_dwelling": 12764}, "energy_consumption_current": 573, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 210, "environmental_impact_current": 32, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 90, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090560509, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM9 4TY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MALDON", "built_form": 4, "created_at": "2017-08-11 14:33:06", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10122}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Hunt Avenue", "address_line_2": "Heybridge", "assessment_type": "RdSAP", "completion_date": "2017-08-11", "inspection_date": "2017-08-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-08-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.69, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.74, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 42.77, "quantity": "square metres"}, "party_wall_length": {"value": 15.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 42.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 910, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 592, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2155, "impact_of_cavity_insulation": -4895, "space_heating_existing_dwelling": 13239}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 132, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100040284302, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TQ7 2BP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "KINGSBRIDGE", "built_form": 1, "created_at": "2017-07-11 16:33:39.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1181}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Compton Road", "address_line_2": "West Charleton", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.1, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 836, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 35, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 282, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 37}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 7, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 8, "typical_saving": {"value": 179, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 9, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 10, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4133, "impact_of_loft_insulation": -1269, "space_heating_existing_dwelling": 12652}, "energy_consumption_current": 281, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 84, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "F", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 42086386, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 18% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CH44 9EB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 4, "created_at": "2017-10-04 16:54:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 107, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "67, Park Road", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.02, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.74, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.83, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.87, "quantity": "metres"}, "total_floor_area": {"value": 39.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.4, "quantity": "square metres"}, "party_wall_length": 4.23, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.18, "quantity": "metres"}, "total_floor_area": {"value": 13.4, "quantity": "square metres"}, "party_wall_length": 4.23, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1286, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 462, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 120, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 130, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 132, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2258, "impact_of_loft_insulation": -4598, "impact_of_solid_wall_insulation": -5175, "space_heating_existing_dwelling": 18481}, "energy_consumption_current": 394, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 81, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 963, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS10 6LD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2017-07-11 23:48:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8497}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Pensfield Park", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 8.12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 8.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 792, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 530, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 167, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.9, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2110, "impact_of_loft_insulation": -1910, "impact_of_cavity_insulation": -3219, "space_heating_existing_dwelling": 12122}, "energy_consumption_current": 314, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 130, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10033560456, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "W9 3BB", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-12 19:01:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 109, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "121c Portnall Road", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-11", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 38.96, "quantity": "square metres"}, "party_wall_length": {"value": 15.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 14.78, "quantity": "square metres"}, "party_wall_length": {"value": 4.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 554, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 244, "currency": "GBP"}, "hot_water_cost_current": {"value": 237, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 68, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3224, "impact_of_loft_insulation": -384, "impact_of_solid_wall_insulation": -2365, "space_heating_existing_dwelling": 6496}, "energy_consumption_current": 409, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 153, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100120626162, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B98 0NJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "REDDITCH", "built_form": 2, "created_at": "2017-04-13 11:43:24.000000", "door_count": 2, "glazed_area": 3, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15445}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "26, Leysters Close", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.42, "quantity": "metres"}}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.7576, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.96, "quantity": "square metres"}, "party_wall_length": {"value": 8.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.82, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 342, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "space_heating_existing_dwelling": 4817}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 138, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10070123218, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PE19 6AY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. NEOTS", "built_form": 1, "created_at": "2017-09-11 20:11:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15445}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "9, Briar Court", "assessment_type": "RdSAP", "completion_date": "2017-09-11", "inspection_date": "2017-09-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.2, "quantity": "metres"}}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.19, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 59.04, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 233, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 235, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1844, "space_heating_existing_dwelling": 2568}, "energy_consumption_current": 135, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 130, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100022598694, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "E17 5HB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-04-11 13:53:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "155, Winns Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 72, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 71.57, "quantity": "square metres"}, "party_wall_length": {"value": 23.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1004, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 719, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 10, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}], "co2_emissions_potential": 3.9, "energy_rating_potential": 56, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2021, "impact_of_loft_insulation": -5068, "impact_of_solid_wall_insulation": -4279, "space_heating_existing_dwelling": 14057}, "energy_consumption_current": 431, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "9.0.0", "energy_consumption_potential": 306, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 49, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100060823980, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT2 0ER", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CANTERBURY", "built_form": 2, "created_at": "2017-05-11 15:35:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "37, Staines Hill", "address_line_2": "Sturry", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 264, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.04, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 44.04, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 815, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 186, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 224, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 133, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 143, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2860, "impact_of_cavity_insulation": -3706, "space_heating_existing_dwelling": 11570}, "energy_consumption_current": 314, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 79, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100120528497, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL6 0RN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "STROUD", "built_form": 2, "created_at": "2017-10-11 21:06:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230001, "number_of_heaters": 2, "high_heat_retention": "true"}, {"index_number": 230002, "number_of_heaters": 1, "high_heat_retention": "true"}], "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "28, Hanover Gardens", "address_line_2": "Chestnut Hill", "address_line_3": "Nailsworth", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.4}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 50.32, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 282, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 158, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1998, "space_heating_existing_dwelling": 3358}, "energy_consumption_current": 348, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 317, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 83159101, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF4 4AB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "WAKEFIELD", "built_form": 4, "created_at": "2017-05-11 14:16:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "258, Barnsley Road", "address_line_2": "Flockton", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 111, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, smokeless fuel", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.5, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.4, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 740, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 594, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 69}], "co2_emissions_potential": 3.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 54}}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2501, "impact_of_cavity_insulation": -9785, "space_heating_existing_dwelling": 23226}, "energy_consumption_current": 397, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 146, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100062586631, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN40 1SB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BEXHILL-ON-SEA", "built_form": 1, "created_at": "2017-10-10 17:19:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1436}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 8 Magdalen Court", "address_line_2": "23, Magdalen Road", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.76, "quantity": "metres"}}, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 26.0392, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 87.43, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 50.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 359, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 295, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 159, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 109, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 108, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2856, "space_heating_existing_dwelling": 4038}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100020236997, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DA8 1HP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ERITH", "built_form": 2, "created_at": "2017-09-28 19:20:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "34, Stonecroft Road", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 308, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 252, "currency": "GBP"}, "hot_water_cost_current": {"value": 176, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 96, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2575, "space_heating_existing_dwelling": 3519}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 130, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 14028272, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG5 3PS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 2, "created_at": "2017-10-11 15:55:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "124, Drovers Way", "address_line_2": "Woodley", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.89, "quantity": "square metres"}, "party_wall_length": {"value": 6.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.14, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 327, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 284, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1857, "space_heating_existing_dwelling": 4514}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 153, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200002700113, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN13 3UU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 3}, "post_town": "WORTHING", "built_form": 1, "created_at": "2017-04-11 13:39:28", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 27, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, LPG", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Chestnut Tree House", "address_line_2": "The Street", "address_line_3": "Clapham", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-10", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 111, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.36, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 59.94, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 34.12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.05, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1356, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 34, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 896, "currency": "GBP"}, "hot_water_cost_current": {"value": 268, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 198, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.1, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 456, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 476, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2729, "impact_of_loft_insulation": -883, "space_heating_existing_dwelling": 12913}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 101, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100091405497, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NR33 0BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LOWESTOFT", "built_form": 4, "created_at": "2017-04-10 19:12:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 195, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "5, Kirkley Cliff", "assessment_type": "RdSAP", "completion_date": "2017-04-10", "inspection_date": "2017-04-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.72, "quantity": "metres"}}, "total_floor_area": 58, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 28.091, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.89, "quantity": "metres"}, "total_floor_area": {"value": 57.54, "quantity": "square metres"}, "party_wall_length": {"value": 15.73, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 493, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 148, "currency": "GBP"}, "hot_water_cost_current": {"value": 180, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 180, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2574, "impact_of_solid_wall_insulation": -3704, "space_heating_existing_dwelling": 6659}, "energy_consumption_current": 527, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 249, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 89, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45114826, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR3 3LA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 03:24:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Arbroath Road", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-01-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 30, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 449, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1859, "space_heating_existing_dwelling": 6463}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 108, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 72052414, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LS11 9LZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 5, "created_at": "2017-06-08 18:54:58.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10068}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Enclosed-end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Crosby Terrace", "assessment_type": "RdSAP", "completion_date": "2017-06-08", "inspection_date": "2017-05-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 17.04, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.08, "quantity": "square metres"}, "party_wall_length": {"value": 9.93, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.93, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 24.08, "quantity": "square metres"}, "party_wall_length": {"value": 9.93, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 829, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 413, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 228, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1936, "impact_of_solid_wall_insulation": -2681, "space_heating_existing_dwelling": 14261}, "energy_consumption_current": 387, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 102, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050586999, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 54% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO30 5TU", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "YORK", "built_form": 1, "created_at": "2017-10-10 16:13:29.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Staindale Close", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 49.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1093, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 489, "currency": "GBP"}, "hot_water_cost_current": {"value": 326, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 17, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 7, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 9, "typical_saving": {"value": 191, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 10, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 11, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 12, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 237, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4479, "impact_of_loft_insulation": -706, "impact_of_cavity_insulation": -3151, "space_heating_existing_dwelling": 14339}, "energy_consumption_current": 416, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "2.13r09", "energy_consumption_potential": 99, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100071079639, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WS2 9TH", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WALSALL", "built_form": 2, "created_at": "2017-07-11 10:32:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "No system present: electric heaters assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, Reservoir Close", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "true", "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.27, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.01, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 34.99, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.01, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1036, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "None", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 468, "currency": "GBP"}, "hot_water_cost_current": {"value": 315, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 611, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 738, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 679, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2007, "space_heating_existing_dwelling": 6601}, "energy_consumption_current": 422, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 240, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "F", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100040186902, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "EX11 1JH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OTTERY ST. MARY", "built_form": 1, "created_at": "2017-07-11 07:53:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1964}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "53, Chineway Gardens", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.77, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 30.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 49.89, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 615, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 444, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 119, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2779, "space_heating_existing_dwelling": 8163}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 76, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 63097011, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF10 3LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CASTLEFORD", "built_form": 3, "created_at": "2017-05-10 20:26:25.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Royds Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-10", "inspection_date": "2017-05-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 42.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 741, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 423, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2286, "impact_of_loft_insulation": -229, "impact_of_solid_wall_insulation": -5697, "space_heating_existing_dwelling": 12846}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 88, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 1775089927, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 91% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO4 9TX", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SOUTHSEA", "built_form": 4, "created_at": "2017-06-05 12:22:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Dunn Close", "assessment_type": "RdSAP", "completion_date": "2017-06-05", "inspection_date": "2017-02-10", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 95, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.35, "quantity": "square metres"}, "party_wall_length": {"value": 19.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 51.3, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 91, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 492, "currency": "GBP"}, "hot_water_cost_current": {"value": 193, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3383, "space_heating_existing_dwelling": 6382}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100090524217, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CM17 9PA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARLOW", "built_form": 2, "created_at": "2017-05-10 22:25:54.000000", "door_count": 2, "glazed_area": 2, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, Bentley Drive", "assessment_type": "RdSAP", "completion_date": "2017-05-10", "inspection_date": "2017-05-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.03, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 39.03, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2680, "impact_of_loft_insulation": -259, "space_heating_existing_dwelling": 7391}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 102, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100020940941, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SE3 9QA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-06 17:42:55.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10577}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "18, Birdbrook Road", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.72, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 31.72, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.24, "quantity": "square metres"}, "party_wall_length": {"value": 2.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 412, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 329, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1997, "impact_of_cavity_insulation": -1300, "space_heating_existing_dwelling": 5757}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 59, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10012775636, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD22 0JY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KEIGHLEY", "built_form": 4, "created_at": "2017-10-16 18:21:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8051}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "6, Lane Ends", "address_line_2": "Cowling", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.97, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.35, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.97, "quantity": "metres"}, "total_floor_area": {"value": 37.35, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.51, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 755, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 547, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2102, "impact_of_solid_wall_insulation": -2899, "space_heating_existing_dwelling": 11730}, "energy_consumption_current": 302, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 138, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 5300081143, "roofs": [{"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "N19 5DY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-10-26 07:58:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15021}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "233, Salisbury Walk", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 46.8, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 303, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 262, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2320, "impact_of_cavity_insulation": -953, "space_heating_existing_dwelling": 4110}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["O"], "calculation_software_version": "2.13r13", "energy_consumption_potential": 192, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100090794066, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP24 3BE", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "THETFORD", "built_form": 3, "created_at": "2017-07-24 08:09:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "7, Williamson Crescent", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.391, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.28, "quantity": "square metres"}, "party_wall_length": {"value": 6.223, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 558, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 368, "currency": "GBP"}, "hot_water_cost_current": {"value": 240, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 8, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 115, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3265, "impact_of_loft_insulation": -353, "space_heating_existing_dwelling": 6725}, "energy_consumption_current": 386, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200003691940, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ME15 6LU", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDSTONE", "built_form": 2, "created_at": "2017-09-24 11:50:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "18, Knightrider Street", "assessment_type": "RdSAP", "completion_date": "2017-09-24", "inspection_date": "2017-09-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.84, "wall_dry_lined": "N", "wall_thickness": 230, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.61, "quantity": "square metres"}, "party_wall_length": {"value": 16.99, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 567, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 324, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.0, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1935, "impact_of_cavity_insulation": -1549, "impact_of_solid_wall_insulation": -1615, "space_heating_existing_dwelling": 8284}, "energy_consumption_current": 358, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 212, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 22220458, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN2 9NE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIGHTON", "built_form": 4, "created_at": "2017-04-27 16:52:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17485}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Albion Street", "assessment_type": "RdSAP", "completion_date": "2017-04-27", "inspection_date": "2017-04-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-04-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 32.37, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.17, "quantity": "square metres"}, "party_wall_length": {"value": 17.62, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 14.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 47.21, "quantity": "square metres"}, "party_wall_length": {"value": 16.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 479, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.6, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2651, "space_heating_existing_dwelling": 7850}, "energy_consumption_current": 125, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 67, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100061815593, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH13 5JG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORSHAM", "built_form": 2, "created_at": "2017-04-19 19:37:40.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "45, Macleod Road", "assessment_type": "RdSAP", "completion_date": "2017-04-19", "inspection_date": "2017-04-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.19, "quantity": "square metres"}, "party_wall_length": {"value": 7.13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 44.19, "quantity": "square metres"}, "party_wall_length": {"value": 7.13, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 518, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 481, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2716, "space_heating_existing_dwelling": 8610}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100120941812, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "access_issues": "true"}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "OX18 3PF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARTERTON", "built_form": 4, "created_at": "2017-06-19 12:04:35.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 9777}], "immersion_heating_type": "NA", "secondary_heating_type": 604, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Lord Close", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.268, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.524, "quantity": "square metres"}, "party_wall_length": {"value": 16.428, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.302, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 50.524, "quantity": "square metres"}, "party_wall_length": {"value": 16.428, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.302, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 623, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 512, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2919, "space_heating_existing_dwelling": 9438}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 96, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050763151, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DN7 5QW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DONCASTER", "built_form": 2, "created_at": "2017-07-19 20:50:59.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10501}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "145, Princess Avenue", "address_line_2": "Stainforth", "assessment_type": "RdSAP", "completion_date": "2017-07-19", "inspection_date": "2017-07-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.25, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 37.92, "quantity": "square metres"}, "party_wall_length": {"value": 3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.32, "quantity": "square metres"}, "party_wall_length": {"value": 2.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 815, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 234, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2155, "impact_of_loft_insulation": -231, "impact_of_cavity_insulation": -4882, "space_heating_existing_dwelling": 14459}, "energy_consumption_current": 300, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 120, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100032175905, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PE9 2GA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "STAMFORD", "built_form": 4, "created_at": "2017-04-19 22:42:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Wothorpe Mews", "assessment_type": "RdSAP", "completion_date": "2017-04-19", "inspection_date": "2017-04-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 5.83, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 3.06, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.461, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.396, "quantity": "square metres"}, "party_wall_length": {"value": 15.578, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.921, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.461, "quantity": "metres"}, "total_floor_area": {"value": 29.396, "quantity": "square metres"}, "party_wall_length": {"value": 15.578, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.548, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 428, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 431, "currency": "GBP"}, "hot_water_cost_current": {"value": 64, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 37, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1396, "impact_of_loft_insulation": -305, "space_heating_existing_dwelling": 6365}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 89, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100081083079, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 53% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SL9 9ER", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GERRARDS CROSS", "built_form": 2, "created_at": "2017-04-20 08:41:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "St. Louis", "address_line_2": "Churchfield Road", "address_line_3": "Chalfont St. Peter", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 53.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 893, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 328, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2260, "impact_of_solid_wall_insulation": -5803, "space_heating_existing_dwelling": 13693}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 77, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100030244820, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DE12 6NW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWADLINCOTE", "built_form": 3, "created_at": "2017-05-19 14:11:11.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Bailey Avenue", "address_line_2": "Overseal", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.277, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.735, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.266, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.305, "quantity": "metres"}, "total_floor_area": {"value": 39.735, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 18.728, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.305, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.498, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 478, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1986, "space_heating_existing_dwelling": 8879}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.92, "energy_consumption_potential": 95, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100060518793, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO40 4SR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2017-05-19 12:29:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15101}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Shorefield Road", "address_line_2": "Marchwood", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.294, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.995, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.936, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.312, "quantity": "metres"}, "total_floor_area": {"value": 48.065, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.586, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 512, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 440, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2891, "impact_of_loft_insulation": -646, "space_heating_existing_dwelling": 8278}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 80, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100081046640, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 98% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL6 3RA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "MAIDENHEAD", "built_form": 2, "created_at": "2017-10-20 16:01:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1182}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Vine House", "address_line_2": "Coronation Road", "address_line_3": "Littlewick Green", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-19", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 178, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.57, "quantity": "square metres"}, "party_wall_length": {"value": 9.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 61.57, "quantity": "square metres"}, "party_wall_length": {"value": 9.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.04, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 6.36, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 5, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 98, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 850, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 687, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 191, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 68}], "co2_emissions_potential": 4.5, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3007, "impact_of_loft_insulation": -406, "space_heating_existing_dwelling": 12871}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 91, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 49, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 48} +{"uprn": 100121092932, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 18% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BA14 0BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TROWBRIDGE", "built_form": 4, "created_at": "2017-07-19 18:07:03", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Rock Road", "assessment_type": "RdSAP", "completion_date": "2017-07-19", "inspection_date": "2017-07-19", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 105, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 24.76, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.02, "quantity": "square metres"}, "party_wall_length": {"value": 16.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 32.88, "quantity": "square metres"}, "party_wall_length": {"value": 16.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.92, "quantity": "square metres"}, "party_wall_length": 3.67, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.67, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 8.92, "quantity": "square metres"}, "party_wall_length": 3.67, "heat_loss_perimeter": {"value": 6.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.35, "quantity": "square metres"}, "party_wall_length": 2.2, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 987, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 566, "currency": "GBP"}, "hot_water_cost_current": {"value": 76, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 159, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 44, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1662, "impact_of_loft_insulation": -890, "impact_of_solid_wall_insulation": -2893, "space_heating_existing_dwelling": 17890}, "energy_consumption_current": 285, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 88, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 97, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 23112116, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 8% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "OL11 5UT", "hot_water": {"description": {"value": "Oil range cooker, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "ROCHDALE", "built_form": 3, "created_at": "2017-05-19 15:09:52", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 927, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Higher Clough", "address_line_2": "Carr Wood", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 147, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.09, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.77, "quantity": "square metres"}, "party_wall_length": {"value": 5.03, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 76.96, "quantity": "square metres"}, "party_wall_length": {"value": 5.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 35.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 4281, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 15, "energy_rating_average": 60, "energy_rating_current": 3, "lighting_cost_current": {"value": 154, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 755, "currency": "GBP"}, "hot_water_cost_current": {"value": 261, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 961, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 14, "environmental_impact_rating": 29}, {"sequence": 2, "typical_saving": {"value": 1615, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 231, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 780, "currency": "GBP"}, "indicative_cost": "\u00a32,400 - \u00a33,600", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 65}], "co2_emissions_potential": 5.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 925, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 888, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3793, "impact_of_loft_insulation": -6872, "impact_of_solid_wall_insulation": -11552, "space_heating_existing_dwelling": 30621}, "energy_consumption_current": 653, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 212, "environmental_impact_current": 20, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "G", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 104, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10009565926, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 8% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HR3 5QX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HEREFORD", "built_form": 1, "created_at": "2017-05-23 20:25:33.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Rostrevor", "address_line_2": "Cusop, Hay-on-Wye", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.02, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.453, "quantity": "metres"}, "total_floor_area": {"value": 45.02, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1000, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 607, "currency": "GBP"}, "hot_water_cost_current": {"value": 172, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3294, "impact_of_loft_insulation": -747, "impact_of_cavity_insulation": -6455, "space_heating_existing_dwelling": 17736}, "energy_consumption_current": 338, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 130, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100031777835, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST16 3QJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 2, "created_at": "2017-06-19 14:13:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 914, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2100, "main_heating_category": 2, "main_heating_fraction": 0, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "48, Pike Close", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 40.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 40.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1885, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 24, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 555, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 400, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 440, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 501, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.8, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 379, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 90}, {"sequence": 3, "typical_saving": {"value": 406, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 574, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2120, "impact_of_cavity_insulation": -2828, "space_heating_existing_dwelling": 13136}, "energy_consumption_current": 559, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 195, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "F", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 95, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10023346436, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD1 4PB", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRADFORD", "built_form": 6, "created_at": "2017-04-25 13:51:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 16", "address_line_2": "Hennymoor House", "address_line_3": "7-11 Manor Row", "assessment_type": "RdSAP", "completion_date": "2017-04-25", "inspection_date": "2017-04-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.89, "quantity": "metres"}}, "total_floor_area": 31, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-04-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 640, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.8762, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 31.34, "quantity": "square metres"}, "party_wall_length": {"value": 14.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 112, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.9, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 112, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 883, "space_heating_existing_dwelling": 720}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 174, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "B", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 2630166864, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR9 3FF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORWICH", "built_form": 2, "created_at": "2017-06-19 18:21:02.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Campion Way", "address_line_2": "Hethersett", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 156, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 37.13, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "J", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.13, "quantity": "square metres"}, "party_wall_length": {"value": 7.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 37.13, "quantity": "square metres"}, "party_wall_length": {"value": 7.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 1, "sap_room_in_roof": {"floor_area": {"value": 22.12, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "J", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 13.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 616, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 120, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 624, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2669, "space_heating_existing_dwelling": 10800}, "energy_consumption_current": 136, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 88, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100021382541, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM5 3TD", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "ROMFORD", "built_form": 1, "created_at": "2017-10-20 10:40:00.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "67, Lawns Way", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.1, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 847, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 344, "currency": "GBP"}, "hot_water_cost_current": {"value": 226, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 10, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.8, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 110, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3285, "impact_of_solid_wall_insulation": -4261, "space_heating_existing_dwelling": 11543}, "energy_consumption_current": 520, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 75, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 92, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061402065, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GU2 9SW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GUILDFORD", "built_form": 1, "created_at": "2017-09-19 16:06:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8067}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "94, Shepherds Lane", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-09-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.509, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.466, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.061, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 45.158, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.316, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 726, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 570, "currency": "GBP"}, "hot_water_cost_current": {"value": 160, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2733, "space_heating_existing_dwelling": 9520}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 114, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100090397667, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 14% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CM2 6SX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "CHELMSFORD", "built_form": 2, "created_at": "2017-05-19 19:01:51.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "24, Earlsfield Drive", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.42, "quantity": "metres"}}, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.894, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 50.85, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 395, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 280, "currency": "GBP"}, "hot_water_cost_current": {"value": 218, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 58}], "co2_emissions_potential": 2.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 246, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 216, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1618, "impact_of_loft_insulation": -429, "space_heating_existing_dwelling": 4464}, "energy_consumption_current": 395, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 327, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 58, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 15048040, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NN2 6DR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 4, "created_at": "2017-05-19 20:45:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Essex Street", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.77, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 33.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.77, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 597, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 404, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2074, "impact_of_cavity_insulation": -764, "impact_of_solid_wall_insulation": -2758, "space_heating_existing_dwelling": 10299}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 207196768, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EN1 4EJ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "ENFIELD", "built_form": 2, "created_at": "2017-10-19 13:36:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "59, Maltby Drive", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 6.1}, "total_floor_area": 36, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.03, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 35.72, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 348, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 299, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 59}], "co2_emissions_potential": 2.2, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1671, "impact_of_loft_insulation": -448, "space_heating_existing_dwelling": 3329}, "energy_consumption_current": 453, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 367, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100070658216, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"access_issues": "true", "addendum_numbers": [9], "cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CV2 4JE", "hot_water": {"description": "Gas multipoint", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "COVENTRY", "built_form": 4, "created_at": "2017-10-28 13:00:06.000000", "door_count": 2, "glazed_area": 4, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.5, "sap_main_heating_code": 603, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.5, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 1.64, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"orientation": 5, "window_area": {"value": 1.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 2.49, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"orientation": 5, "window_area": {"value": 1.73, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 3, "window_area": {"value": 0.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"orientation": 5, "window_area": {"value": 0.68, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "130, Hastings Road", "assessment_type": "RdSAP", "completion_date": "2017-10-28", "inspection_date": "2017-10-27", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.6, "quantity": "square metres"}, "party_wall_length": {"value": 16.37, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.83, "quantity": "metres"}, "total_floor_area": {"value": 27.6, "quantity": "square metres"}, "party_wall_length": {"value": 16.37, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.02, "quantity": "square metres"}, "party_wall_length": {"value": 4.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.13, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1072, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 503, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 9, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1424, "impact_of_loft_insulation": -653, "impact_of_cavity_insulation": -450, "impact_of_solid_wall_insulation": -2816, "space_heating_existing_dwelling": 9260}, "energy_consumption_current": 421, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 105, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45119095, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR2 0JZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 4, "created_at": "2017-06-01 06:26:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "3, Wraith Terrace", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2016-12-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.2, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 533, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 5, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 394, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1694, "space_heating_existing_dwelling": 6857}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "1.0.x", "energy_consumption_potential": 88, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100010195086, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CW8 3HY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHWICH", "built_form": 2, "created_at": "2017-09-12 17:16:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Russet Road", "address_line_2": "Weaverham", "assessment_type": "RdSAP", "completion_date": "2017-09-12", "inspection_date": "2017-09-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.55, "quantity": "square metres"}, "party_wall_length": {"value": 5.66, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 20.54, "quantity": "square metres"}, "party_wall_length": {"value": 5.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.97, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.03, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 21.03, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.39, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 541, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 498, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1986, "space_heating_existing_dwelling": 8304}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 63004288, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF9 4RP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTEFRACT", "built_form": 2, "created_at": "2017-09-13 09:05:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "72, Ashfield Road", "address_line_2": "Hemsworth", "assessment_type": "RdSAP", "completion_date": "2017-09-13", "inspection_date": "2017-09-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 46.2, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 647, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 593, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2332, "space_heating_existing_dwelling": 9390}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 127, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100100477436, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF31 4DP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIDGEND", "built_form": 2, "created_at": "2017-07-13 15:43:38.000000", "door_count": 0, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Bryn Awelon", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.42, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2242, "impact_of_loft_insulation": -871, "space_heating_existing_dwelling": 7178}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 77, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 60012562, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN43 6HR", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SHOREHAM-BY-SEA", "built_form": 3, "created_at": "2017-04-29 13:42:26.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "65, Greenways Crescent", "assessment_type": "RdSAP", "completion_date": "2017-04-29", "inspection_date": "2017-04-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.504, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.77, "quantity": "square metres"}, "party_wall_length": {"value": 6.569, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.482, "quantity": "metres"}, "total_floor_area": {"value": 38.27, "quantity": "square metres"}, "party_wall_length": {"value": 6.569, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 995, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.8, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 453, "currency": "GBP"}, "hot_water_cost_current": {"value": 693, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 364, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 32}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 35}, {"sequence": 3, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 41}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 378, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 43, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 332, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 355, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 415, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5046, "impact_of_cavity_insulation": -4189, "space_heating_existing_dwelling": 11371}, "energy_consumption_current": 675, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 84, "environmental_impact_current": 20, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "F", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 114, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 310003811, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG30 2RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 3, "created_at": "2017-05-12 15:37:53.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10315}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "133, Beecham Road", "assessment_type": "RdSAP", "completion_date": "2017-05-12", "inspection_date": "2017-05-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.52, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 7.5, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 854, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 449, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 355, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2105, "impact_of_solid_wall_insulation": -6756, "space_heating_existing_dwelling": 13997}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 94, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 45005215, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DH5 8DP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-07-12 10:07:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15695}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, Kirklea Road", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 30.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 491, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1931, "space_heating_existing_dwelling": 8880}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 135, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10024429897, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PR7 3LY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHORLEY", "built_form": 3, "created_at": "2017-07-12 16:35:06.000000", "door_count": 3, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Silvester Road", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 33.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 305, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 305, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.7, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1811, "space_heating_existing_dwelling": 4190}, "energy_consumption_current": 145, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 56, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 42049382, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH44 1DN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 4, "created_at": "2017-07-12 21:04:27.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1730}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "38, Greenwood Lane", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.768, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.063, "quantity": "square metres"}, "party_wall_length": {"value": 13.576, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.681, "quantity": "metres"}, "total_floor_area": {"value": 32.155, "quantity": "square metres"}, "party_wall_length": {"value": 13.576, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.539, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.312, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.784, "quantity": "square metres"}, "party_wall_length": {"value": 2.552, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.587, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.214, "quantity": "metres"}, "total_floor_area": {"value": 7.784, "quantity": "square metres"}, "party_wall_length": {"value": 2.552, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.587, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 629, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 182, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2117, "impact_of_loft_insulation": -384, "impact_of_solid_wall_insulation": -3406, "space_heating_existing_dwelling": 9440}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10007866584, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN15 6GQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KETTERING", "built_form": 1, "created_at": "2017-10-14 22:54:59.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17982}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "46, The Fairway", "assessment_type": "RdSAP", "completion_date": "2017-10-14", "inspection_date": "2017-10-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 75.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 34.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 451, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 415, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2036, "space_heating_existing_dwelling": 7421}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 91, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100080507448, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HP8 4JZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHALFONT ST. GILES", "built_form": 1, "created_at": "2017-04-12 20:10:18.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17115}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "13, Tripps Hill Close", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 16.31, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "D"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1028, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 662, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 198, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1902, "impact_of_loft_insulation": -3666, "impact_of_cavity_insulation": -2524, "space_heating_existing_dwelling": 19701}, "energy_consumption_current": 381, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 161, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100090238566, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SS14 3PS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BASILDON", "built_form": 3, "created_at": "2017-09-12 15:22:32.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Chesterford Gardens", "assessment_type": "RdSAP", "completion_date": "2017-09-12", "inspection_date": "2017-09-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.67, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.67, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.39, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 420, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2041, "space_heating_existing_dwelling": 7935}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 91, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010928674, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 36% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BL1 7LQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 1, "created_at": "2017-09-13 11:50:05.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16922}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "11, Springfield Road", "assessment_type": "RdSAP", "completion_date": "2017-09-13", "inspection_date": "2017-09-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2017-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 55.53, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 774, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 680, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 252, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2138, "impact_of_loft_insulation": -408, "space_heating_existing_dwelling": 14456}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 137, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100060489332, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH25 7LW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEW MILTON", "built_form": 1, "created_at": "2017-06-12 16:38:39.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Heathwood Avenue", "address_line_2": "Barton on Sea", "assessment_type": "RdSAP", "completion_date": "2017-06-12", "inspection_date": "2017-06-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 174, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-06-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 48.36, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 94.49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 38.43, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1033, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 138, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 958, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2990, "impact_of_loft_insulation": -264, "space_heating_existing_dwelling": 15977}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 23, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100051127119, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD16 4EY", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BINGLEY", "built_form": 1, "created_at": "2017-06-13 02:31:05.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "75, Villa Road", "assessment_type": "RdSAP", "completion_date": "2017-06-13", "inspection_date": "2017-06-12", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.47, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 28.47, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.52, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.77, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 1, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1710, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.9, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1096, "currency": "GBP"}, "hot_water_cost_current": {"value": 252, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 212, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 37}, {"sequence": 3, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 41}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 43}, {"sequence": 5, "typical_saving": {"value": 341, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 7, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 63}], "co2_emissions_potential": 4.9, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 529, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 57}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3438, "impact_of_loft_insulation": -4726, "space_heating_existing_dwelling": 21998}, "energy_consumption_current": 500, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 245, "environmental_impact_current": 32, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 88, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100091157915, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 45% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP19 8TN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HALESWORTH", "built_form": 1, "created_at": "2017-04-12 11:45:55.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15017}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "4, Jermyn Way", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 89.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 44.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 669, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 558, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2865, "space_heating_existing_dwelling": 11316}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 124, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110300840, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CA2 4DA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARLISLE", "built_form": 2, "created_at": "2017-06-12 21:02:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "57, Webster Crescent", "assessment_type": "RdSAP", "completion_date": "2017-06-12", "inspection_date": "2017-06-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 30.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 539, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 488, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2133, "space_heating_existing_dwelling": 7350}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100080825905, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SG8 7EF", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ROYSTON", "built_form": 2, "created_at": "2017-09-12 18:39:14.000000", "door_count": 2, "glazed_area": 4, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 506, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "sap_windows": [{"orientation": 1, "window_area": {"value": 3.2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 7, "window_area": {"value": 1.14, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 5, "window_area": {"value": 1.73, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 1.76, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Warm air, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "72, King James Way", "assessment_type": "RdSAP", "completion_date": "2017-09-12", "inspection_date": "2017-09-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.52, "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.51, "quantity": "square metres"}, "party_wall_length": {"value": 9.18, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 516, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 399, "currency": "GBP"}, "hot_water_cost_current": {"value": 272, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a31,250 - \u00a32,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 247, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 240, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 243, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1732, "impact_of_cavity_insulation": -287, "space_heating_existing_dwelling": 6063}, "energy_consumption_current": 328, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 95595, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"addendum_numbers": [6]}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS2 8EB", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 4, "created_at": "2017-05-13 16:47:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "11 Bengoughs Almshouses", "address_line_2": "Horfield Road", "assessment_type": "RdSAP", "completion_date": "2017-05-13", "inspection_date": "2017-05-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5, "quantity": "metres"}}, "total_floor_area": 32, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-05-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 180, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 599, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 218, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 5, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.3, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 138, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 887, "impact_of_solid_wall_insulation": -1711, "space_heating_existing_dwelling": 3855}, "energy_consumption_current": 477, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 241, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090526594, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM20 1QG", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HARLOW", "built_form": 4, "created_at": "2017-05-12 14:54:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Canons Gate", "assessment_type": "RdSAP", "completion_date": "2017-05-12", "inspection_date": "2017-05-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.28, "quantity": "square metres"}, "party_wall_length": {"value": 13.44, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 35.28, "quantity": "square metres"}, "party_wall_length": {"value": 13.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 977, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 644, "currency": "GBP"}, "hot_water_cost_current": {"value": 252, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 5, "typical_saving": {"value": 187, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 330, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3381, "impact_of_loft_insulation": -3214, "impact_of_cavity_insulation": -1776, "space_heating_existing_dwelling": 10469}, "energy_consumption_current": 482, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 189, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 85, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 3455050121, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST6 2PG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2017-05-17 21:19:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16814}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Hillary Street", "assessment_type": "RdSAP", "completion_date": "2017-05-17", "inspection_date": "2017-05-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-05-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.98, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.83, "quantity": "square metres"}, "party_wall_length": {"value": 7.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 32.71, "quantity": "square metres"}, "party_wall_length": {"value": 7.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.26, "quantity": "square metres"}, "party_wall_length": {"value": 7.49, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 553, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 441, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 70, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1848, "impact_of_loft_insulation": -262, "impact_of_solid_wall_insulation": -1511, "space_heating_existing_dwelling": 8721}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "1.0.x", "energy_consumption_potential": 102, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100080011244, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 47% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "MK43 7RL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BEDFORD", "built_form": 1, "created_at": "2017-08-18 11:53:53.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1301}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Dewlands", "address_line_2": "Oakley", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-17", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 39, "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 43.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.1, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 8, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 12.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 47, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1143, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 750, "currency": "GBP"}, "hot_water_cost_current": {"value": 188, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 193, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 90}, {"sequence": 3, "typical_saving": {"value": 126, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 351, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2962, "impact_of_cavity_insulation": -2545, "space_heating_existing_dwelling": 14857}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 131, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100020606252, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR0 7XE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CROYDON", "built_form": 4, "created_at": "2017-05-18 07:45:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "58 Seymour Court", "address_line_2": "Kempton Walk", "assessment_type": "RdSAP", "completion_date": "2017-05-18", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50, "quantity": "square metres"}, "party_wall_length": {"value": 20, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 50, "quantity": "square metres"}, "party_wall_length": {"value": 20, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 525, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 45, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1644, "impact_of_cavity_insulation": -836, "space_heating_existing_dwelling": 8781}, "energy_consumption_current": 159, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 66, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 22024202, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN3 4FH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOVE", "built_form": 3, "created_at": "2017-05-17 20:48:05.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 9 Aymer House", "address_line_2": "10-12, New Church Road", "assessment_type": "RdSAP", "completion_date": "2017-05-17", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 58, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-05-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.11, "quantity": "square metres"}, "party_wall_length": {"value": 12.41, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 401, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 277, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1661, "space_heating_existing_dwelling": 6127}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 145, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100071183230, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WV10 6TJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 2, "created_at": "2017-05-17 20:02:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9505}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Oxley Links Road", "assessment_type": "RdSAP", "completion_date": "2017-05-17", "inspection_date": "2017-05-17", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 123, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2017-05-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.28, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 44.28, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.26, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.32, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1314, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 898, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 3.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2297, "impact_of_loft_insulation": -3676, "impact_of_solid_wall_insulation": -4879, "space_heating_existing_dwelling": 22105}, "energy_consumption_current": 335, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 173, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100100285815, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA61 1EG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HAVERFORDWEST", "built_form": 4, "created_at": "2017-05-22 13:51:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Portfield Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-22", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.206, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 36.206, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.84, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 334, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 334, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2194, "space_heating_existing_dwelling": 4496}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 53, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 21003856, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU3 1DX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 4, "created_at": "2017-07-17 19:49:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10233}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "90, Alexandra Street", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 65.64, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.67, "quantity": "square metres"}, "party_wall_length": {"value": 9.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 41.67, "quantity": "square metres"}, "party_wall_length": {"value": 9.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.36, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 709, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 672, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2138, "impact_of_loft_insulation": -2270, "space_heating_existing_dwelling": 10246}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 159, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100050498912, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO21 3RT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WHITBY", "built_form": 4, "created_at": "2017-04-10 18:16:51.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17520}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Topcliffe House", "address_line_2": "High Street", "address_line_3": "Lythe", "assessment_type": "RdSAP", "completion_date": "2017-04-10", "inspection_date": "2017-03-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 524, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 374, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 126, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3318, "space_heating_existing_dwelling": 10680}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100110379694, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DH8 8HT", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "CONSETT", "built_form": 2, "created_at": "2017-05-18 23:28:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "71, Surrey Crescent", "assessment_type": "RdSAP", "completion_date": "2017-05-18", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 70, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 903, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 642, "currency": "GBP"}, "hot_water_cost_current": {"value": 382, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 400, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 273, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 178, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 497, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5079, "impact_of_loft_insulation": -3574, "space_heating_existing_dwelling": 11489}, "energy_consumption_current": 510, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "9.0.0", "energy_consumption_potential": 196, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 90, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 45106048, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DH5 8EH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-05-31 20:19:09.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Seaton Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2017-01-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.5, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.5, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 573, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 530, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2060, "space_heating_existing_dwelling": 7930}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 121, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100091314047, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR9 5BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NORWICH", "built_form": 1, "created_at": "2017-06-15 05:33:57.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 125, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Conifers", "address_line_2": "Colton Road", "address_line_3": "Honingham", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 122, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 31.96, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 954, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 470, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2966, "impact_of_loft_insulation": -836, "space_heating_existing_dwelling": 13546}, "energy_consumption_current": 250, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100031252920, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG17 5EB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUTTON-IN-ASHFIELD", "built_form": 2, "created_at": "2017-08-16 09:26:19.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "22, Limb Crescent", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.25, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 369, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 325, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1580, "space_heating_existing_dwelling": 5414}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 80, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100022528090, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 55% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E17 4AR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-08-17 16:28:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "65, Castleton Road", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, coal", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 235, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.53, "quantity": "square metres"}, "party_wall_length": {"value": 7.47, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 44.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.47, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 235, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1282, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 35, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 3, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 706, "currency": "GBP"}, "hot_water_cost_current": {"value": 169, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 390, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 39}, {"sequence": 4, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 45}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 47}, {"sequence": 6, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 49}, {"sequence": 7, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 57}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 290, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 56}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2889, "impact_of_loft_insulation": -3665, "impact_of_solid_wall_insulation": -6378, "space_heating_existing_dwelling": 18597}, "energy_consumption_current": 434, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 31, "calculation_software_version": "2.12r11", "energy_consumption_potential": 161, "environmental_impact_current": 23, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 90, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 21123681, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HU3 2SE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 3, "created_at": "2017-09-15 16:52:17.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16645}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "267 Anlaby Road", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3.43}, "total_floor_area": 25, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.8151, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.3, "quantity": "square metres"}, "party_wall_length": {"value": 10, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 372, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 214, "currency": "GBP"}, "hot_water_cost_current": {"value": 66, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.0, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1376, "impact_of_solid_wall_insulation": -2512, "space_heating_existing_dwelling": 5198}, "energy_consumption_current": 420, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 236, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100091061898, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP3 8QN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IPSWICH", "built_form": 2, "created_at": "2017-08-14 13:18:10.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "9, Melplash Close", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78.79, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.39, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 590, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 477, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2137, "space_heating_existing_dwelling": 9256}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 93, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100030198090, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S45 9NH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "CHESTERFIELD", "built_form": 4, "created_at": "2017-09-15 10:00:24.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "46, Brassington Street", "address_line_2": "Clay Cross", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.4, "quantity": "square metres"}, "party_wall_length": {"value": 13.86, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 27.4, "quantity": "square metres"}, "party_wall_length": {"value": 13.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.77, "quantity": "square metres"}, "party_wall_length": {"value": 2.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 587, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2199, "impact_of_loft_insulation": -278, "impact_of_cavity_insulation": -905, "impact_of_solid_wall_insulation": -1435, "space_heating_existing_dwelling": 10364}, "energy_consumption_current": 300, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "2.12r11", "energy_consumption_potential": 123, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200003822974, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B93 8SN", "hot_water": {"description": "Community scheme, no cylinder thermostat", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOLIHULL", "built_form": 6, "created_at": "2017-07-19 16:15:10.000000", "door_count": 0, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 14 Blanning Court", "address_line_2": "2, Michael Blanning Gardens", "address_line_3": "Dorridge", "assessment_type": "RdSAP", "completion_date": "2017-07-19", "inspection_date": "2017-07-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 42, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-07-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 18.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 198, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 198, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 125, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2168, "impact_of_loft_insulation": -327, "space_heating_existing_dwelling": 1614}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 182, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10000047993, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PE34 4QL", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "KING'S LYNN", "built_form": 1, "created_at": "2017-10-17 10:18:26", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 694, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Annex", "address_line_2": "18 St. Johns Road", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 25, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 50}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.46, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.46, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 277, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.9, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 164, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 83}, {"sequence": 4, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 96, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.5, "energy_rating_potential": 96, "lighting_cost_potential": {"value": 26, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 176, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 96, "environmental_impact_rating": 108}, {"sequence": 2, "typical_saving": {"value": 150, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 94, "environmental_impact_rating": 96}], "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 848, "impact_of_loft_insulation": -170, "space_heating_existing_dwelling": 1952}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 119, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "B", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060556231, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SP10 2HE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ANDOVER", "built_form": 1, "created_at": "2017-10-18 20:42:33", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5929}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, Chestnut Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-18", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 42.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.99, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 4.18, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "D"}, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.76, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.11, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 845, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 621, "currency": "GBP"}, "hot_water_cost_current": {"value": 158, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 157, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2815, "impact_of_loft_insulation": -246, "space_heating_existing_dwelling": 13205}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 108, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 45117891, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE38 7PW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WASHINGTON", "built_form": 4, "created_at": "2017-06-01 07:46:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "126, Roche Court", "assessment_type": "RdSAP", "completion_date": "2017-06-01", "inspection_date": "2016-12-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.2, "quantity": "square metres"}, "party_wall_length": {"value": 16.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.7, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "100mm", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 516, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2094, "space_heating_existing_dwelling": 8492}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 83, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 63079089, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF10 5QW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CASTLEFORD", "built_form": 2, "created_at": "2017-10-05 09:06:47.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "33, Netherfield Close", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.7, "quantity": "square metres"}, "party_wall_length": {"value": 9.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 473, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 423, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2072, "space_heating_existing_dwelling": 6323}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 104, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200002845946, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA4 6DH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MORECAMBE", "built_form": 2, "created_at": "2017-10-24 10:12:46.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4033}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 11 Kensington Court", "address_line_2": "Bare Lane", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.47, "quantity": "square metres"}, "party_wall_length": {"value": 8.25, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 291, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2544, "impact_of_cavity_insulation": -2688, "space_heating_existing_dwelling": 7872}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 158, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10001300587, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF43 3LE", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "FERNDALE", "built_form": 4, "created_at": "2017-10-09 16:21:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "21, Llewellyn Street", "address_line_2": "Pontygwaith", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-09", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.02, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1000, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 434, "currency": "GBP"}, "hot_water_cost_current": {"value": 437, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 57}], "co2_emissions_potential": 3.8, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 363, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 325, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 139, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3197, "impact_of_cavity_insulation": -3086, "impact_of_solid_wall_insulation": -795, "space_heating_existing_dwelling": 11354}, "energy_consumption_current": 796, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 397, "environmental_impact_current": 27, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 135, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 21101322, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU6 7EA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 4, "created_at": "2017-10-04 07:32:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "74, Welwyn Park Road", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.45, "quantity": "square metres"}, "party_wall_length": {"value": 13.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 34.45, "quantity": "square metres"}, "party_wall_length": {"value": 13.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.7, "quantity": "square metres"}, "party_wall_length": {"value": 4.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 550, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 421, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2365, "impact_of_cavity_insulation": -375, "impact_of_solid_wall_insulation": -2244, "space_heating_existing_dwelling": 9542}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 90, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200003852575, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "AL6 9BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WELWYN", "built_form": 1, "created_at": "2017-10-12 15:48:55", "door_count": 4, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 125, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Harepark House", "address_line_2": "Bibbs Hall Lane", "address_line_3": "Ayot St. Lawrence", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 224, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "false", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 4, "peak_power": {"value": 1.7, "quantity": "kW"}, "orientation": 5, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 96.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 38.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 96.72, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 36.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 13.96, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.62, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1281, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 131, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1025, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}], "co2_emissions_potential": 5.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 131, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3016, "space_heating_existing_dwelling": 19670}, "energy_consumption_current": 168, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 74, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100100078643, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF11 6JE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2017-10-09 10:45:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10108}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "122b Ninian Park Road", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-06", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 56, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 33.81, "quantity": "square metres"}, "party_wall_length": {"value": 13.72, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 21.79, "quantity": "square metres"}, "party_wall_length": {"value": 7.28, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.29, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 469, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 321, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.9, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2196, "impact_of_loft_insulation": -2225, "impact_of_solid_wall_insulation": -2446, "space_heating_existing_dwelling": 6986}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 193, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 200004247191, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG23 6PF", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NEWARK", "built_form": 1, "created_at": "2017-10-04 18:54:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 633, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Portable electric heaters assumed for most rooms", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "13, Main Street", "address_line_2": "Sutton-on-Trent", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 232, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 40, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 73.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 35.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 21.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 7911, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 26, "energy_rating_average": 60, "energy_rating_current": 1, "lighting_cost_current": {"value": 175, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 3909, "currency": "GBP"}, "hot_water_cost_current": {"value": 227, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 1283, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 1, "environmental_impact_rating": 19}, {"sequence": 2, "typical_saving": {"value": 1699, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 15, "environmental_impact_rating": 30}, {"sequence": 3, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 17, "environmental_impact_rating": 32}, {"sequence": 4, "typical_saving": {"value": 240, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 20, "environmental_impact_rating": 34}, {"sequence": 5, "typical_saving": {"value": 523, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 26, "environmental_impact_rating": 38}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 41}], "co2_emissions_potential": 13, "energy_rating_potential": 29, "lighting_cost_potential": {"value": 179, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 227, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2247, "impact_of_loft_insulation": -2987, "impact_of_solid_wall_insulation": -10055, "space_heating_existing_dwelling": 48557}, "energy_consumption_current": 630, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.13r09", "energy_consumption_potential": 309, "environmental_impact_current": 12, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "G", "environmental_impact_potential": 41, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "F", "co2_emissions_current_per_floor_area": 110, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100120617617, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 8% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B98 0HL", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "REDDITCH", "built_form": 3, "created_at": "2017-10-10 22:05:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 280}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "156, Eathorpe Close", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.28, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 913, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 631, "currency": "GBP"}, "hot_water_cost_current": {"value": 244, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 213, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 279, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3367, "impact_of_loft_insulation": -2909, "space_heating_existing_dwelling": 11722}, "energy_consumption_current": 370, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 151, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100060834173, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 26% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CT6 6UD", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HERNE BAY", "built_form": 1, "created_at": "2017-10-05 13:57:47.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1967}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Highfields View", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 55.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.98, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 11.11, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "E"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.53, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 26, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1016, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 132, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 649, "currency": "GBP"}, "hot_water_cost_current": {"value": 228, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 100, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 9, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 234, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3656, "impact_of_loft_insulation": -543, "space_heating_existing_dwelling": 13540}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 100, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 27, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100110090909, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS1 5LL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLESBROUGH", "built_form": 4, "created_at": "2017-10-24 12:28:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "19, Ammerston Road", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 354, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 317, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1712, "space_heating_existing_dwelling": 4230}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 147, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 200195749, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N11 1LH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-10-11 18:18:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 69 The Homestead", "address_line_2": "Waterfall Road", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 10.58}, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 75.02, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 820, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 653, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}], "co2_emissions_potential": 3.5, "energy_rating_potential": 63, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 182, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 54}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2060, "space_heating_existing_dwelling": 11776}, "energy_consumption_current": 347, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 263, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 766263285, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HP20 1JQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "AYLESBURY", "built_form": 4, "created_at": "2017-10-16 16:43:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16497}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "14, Shaw Close", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.21, "quantity": "square metres"}, "party_wall_length": {"value": 14.34, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 39.21, "quantity": "square metres"}, "party_wall_length": {"value": 14.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 468, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 349, "currency": "GBP"}, "hot_water_cost_current": {"value": 216, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 7, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 126, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3183, "impact_of_loft_insulation": -481, "space_heating_existing_dwelling": 5621}, "energy_consumption_current": 251, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 63, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061929964, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN7 2RF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEWES", "built_form": 3, "created_at": "2017-10-13 18:33:48.000000", "door_count": 0, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16453}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6 Greyfriars Court", "address_line_2": "Court Road", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.5, "quantity": "square metres"}, "party_wall_length": {"value": 16.85, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 290, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 262, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2696, "space_heating_existing_dwelling": 3854}, "energy_consumption_current": 159, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 147, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100091129917, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP5 1AN", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "IPSWICH", "built_form": 2, "created_at": "2017-10-10 16:40:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "21, Beech Road", "address_line_2": "Rushmere St. Andrew", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.46, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.15, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 763, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 484, "currency": "GBP"}, "hot_water_cost_current": {"value": 199, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 42}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 160, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 65}], "co2_emissions_potential": 2.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 272, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 280, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1148, "space_heating_existing_dwelling": 8640}, "energy_consumption_current": 517, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 237, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 87, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 41118974, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PR9 9LS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHPORT", "built_form": 5, "created_at": "2017-10-19 14:20:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 11 Berkley Court", "address_line_2": "Park Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.8, "quantity": "metres"}}, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.138, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 90.8, "quantity": "square metres"}, "party_wall_length": {"value": 13, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 240, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 244, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2326, "space_heating_existing_dwelling": 2747}, "energy_consumption_current": 102, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "B", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 18, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100080339341, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SL1 2TB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SLOUGH", "built_form": 4, "created_at": "2017-10-05 12:33:46.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "52, Tintern Close", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.3, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 46, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1089, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 611, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 130, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 186, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2257, "impact_of_loft_insulation": -487, "impact_of_solid_wall_insulation": -2099, "space_heating_existing_dwelling": 15704}, "energy_consumption_current": 334, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 123, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021373226, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM2 5UX", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ROMFORD", "built_form": 2, "created_at": "2017-10-16 23:15:36.000000", "door_count": 1, "glazed_area": 4, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8558}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "false", "orientation": 1, "window_area": {"value": 3.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "false", "orientation": 8, "window_area": {"value": 6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "false", "orientation": 7, "window_area": {"value": 3.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 6.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 4.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "false", "orientation": 8, "window_area": {"value": 1.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 1.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2}, {"pvc_frame": "false", "orientation": 8, "window_area": {"value": 1.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 3}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 1.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 3}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "86, Fairholme Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-12", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.74, "quantity": "square metres"}, "party_wall_length": {"value": 7.34, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 43.74, "quantity": "square metres"}, "party_wall_length": {"value": 7.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.13, "quantity": "square metres"}, "party_wall_length": 0.93, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 9.15, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 2.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.83, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1158, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 767, "currency": "GBP"}, "hot_water_cost_current": {"value": 213, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 181, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 301, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3640, "impact_of_loft_insulation": -4129, "impact_of_solid_wall_insulation": -4672, "space_heating_existing_dwelling": 17277}, "energy_consumption_current": 330, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 151, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 45129108, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR3 1ER", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 4, "created_at": "2017-10-25 16:26:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "1, Wynyard Street", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 68.05, "quantity": "square metres"}, "party_wall_length": {"value": 16.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 511, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "No time or thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 302, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1976, "impact_of_solid_wall_insulation": -2308, "space_heating_existing_dwelling": 7829}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 147, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200000481491, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW9 9AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-10-20 22:59:05.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 18 Morant House", "address_line_2": "Stockwell Gardens Estate", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 51.8, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 327, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 189, "currency": "GBP"}, "hot_water_cost_current": {"value": 57, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1252, "impact_of_solid_wall_insulation": -3074, "space_heating_existing_dwelling": 4665}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 99, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10024231892, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK40 4GZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 2, "created_at": "2017-10-27 15:55:20.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16400}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "true", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "1, Gleneagles Close", "address_line_2": "Great Denham", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.78, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 32.95, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.12, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 32.95, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 403, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 409, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2373, "space_heating_existing_dwelling": 6344}, "energy_consumption_current": 134, "has_fixed_air_conditioning": "true", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 64, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100090212915, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 30% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PE2 9DQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 4, "created_at": "2017-10-18 17:45:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8788}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "61, Palmerston Road", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-17", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.17, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.53, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 20.17, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2, "quantity": "metres"}, "total_floor_area": {"value": 22.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6, "quantity": "square metres"}, "party_wall_length": {"value": 3.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 811, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2729, "impact_of_loft_insulation": -208, "impact_of_cavity_insulation": -242, "impact_of_solid_wall_insulation": -4593, "space_heating_existing_dwelling": 12592}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.13r12", "energy_consumption_potential": 96, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100070340749, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B31 3RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2017-10-17 18:24:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2053}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "52, Cropredy Road", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.53, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 39.53, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 533, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 448, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2101, "space_heating_existing_dwelling": 8123}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 103, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10093382095, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG45 7AH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CROWTHORNE", "built_form": 4, "created_at": "2017-10-11 12:43:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17843}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "2 Richmond House", "address_line_2": "281 High Street", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.68, "quantity": "square metres"}, "party_wall_length": {"value": 4.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 264, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 264, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 92, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.3, "energy_rating_potential": 92, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1711, "space_heating_existing_dwelling": 3264}, "energy_consumption_current": 162, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 29, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100120644747, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WR2 5ED", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORCESTER", "built_form": 2, "created_at": "2017-10-25 22:55:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15029}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11a, Boughton Close", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.43, "quantity": "square metres"}, "party_wall_length": {"value": 4.88, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.43, "quantity": "square metres"}, "party_wall_length": {"value": 4.88, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.22, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 723, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 534, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2211, "impact_of_loft_insulation": -843, "impact_of_cavity_insulation": -3493, "space_heating_existing_dwelling": 13268}, "energy_consumption_current": 256, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 113, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061429726, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "KT23 4QP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEATHERHEAD", "built_form": 4, "created_at": "2017-06-19 12:08:32.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Ashdale", "address_line_2": "Bookham", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 16.66, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 10.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 16.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 396, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 327, "currency": "GBP"}, "hot_water_cost_current": {"value": 230, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3015, "impact_of_loft_insulation": -200, "space_heating_existing_dwelling": 4086}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 54, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10033533864, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW1W 9DE", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 5, "created_at": "2017-06-15 21:52:29.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2302, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "22, Eaton Square", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": 4.2}, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.08, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 87.21, "quantity": "square metres"}, "party_wall_length": {"value": 16.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1009, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 573, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 447, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.5, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2234, "space_heating_existing_dwelling": 14803}, "energy_consumption_current": 393, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 227, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "E", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 202203391, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA9 0BU", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEMBLEY", "built_form": 4, "created_at": "2017-06-27 10:11:25.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 806 North Block Raffles House", "address_line_2": "6, Lakeside Way", "assessment_type": "RdSAP", "completion_date": "2017-06-27", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 8, "heat_loss_corridor": 1}, "total_floor_area": 17, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2017-06-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 17.38, "quantity": "square metres"}, "party_wall_length": {"value": 8.61, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 109, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.7, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 109, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 19, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1615, "space_heating_existing_dwelling": 287}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 218, "environmental_impact_current": 85, "fixed_lighting_outlets_count": 3, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100121117593, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SN4 0QL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 1, "created_at": "2017-06-15 13:27:15.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10388}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Beranburh Field", "address_line_2": "Wroughton", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 235, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 10, "pvc_window_frames": "true", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 152.76, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 60.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 113.43, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 46.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 2117, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 141, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1367, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 622, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "co2_emissions_potential": 6.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 104, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 124, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 157, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3205, "impact_of_cavity_insulation": -10818, "space_heating_existing_dwelling": 34784}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 147, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100021409020, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly multiple glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 23% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "RM14 3JU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UPMINSTER", "built_form": 2, "created_at": "2017-06-17 14:59:27.000000", "door_count": 2, "glazed_area": 4, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16683}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "false", "orientation": 6, "window_area": {"value": 0.75, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 0.75, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 2.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 1, "window_area": {"value": 4.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 7, "window_area": {"value": 2.75, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 5, "window_area": {"value": 4.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 7, "window_area": {"value": 0.25, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 0.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2}, {"pvc_frame": "false", "orientation": 7, "window_area": {"value": 1.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Lichfield Terrace", "assessment_type": "RdSAP", "completion_date": "2017-06-17", "inspection_date": "2017-06-15", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 30.11, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.91, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.61, "quantity": "square metres"}, "party_wall_length": 3.1, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 23, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1037, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 626, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 331, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1928, "impact_of_loft_insulation": -1316, "impact_of_cavity_insulation": -203, "impact_of_solid_wall_insulation": -6137, "space_heating_existing_dwelling": 16007}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 110, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120790406, "roofs": [{"description": "Pitched, 350 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX5 2DY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KIDLINGTON", "built_form": 2, "created_at": "2017-09-18 16:24:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, Exeter Road", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.98, "quantity": "square metres"}, "party_wall_length": {"value": 7.29, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 37.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 751, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 422, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "impact_of_loft_insulation": -285, "impact_of_solid_wall_insulation": -6040, "space_heating_existing_dwelling": 13032}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 88, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100040679999, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BH22 0LL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FERNDOWN", "built_form": 4, "created_at": "2017-09-24 15:22:49.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 15755}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Bond Avenue", "address_line_2": "West Moors", "assessment_type": "RdSAP", "completion_date": "2017-09-24", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.04, "quantity": "square metres"}, "party_wall_length": {"value": 11.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 41.04, "quantity": "square metres"}, "party_wall_length": {"value": 11.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 397, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 335, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 5, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2821, "space_heating_existing_dwelling": 5220}, "energy_consumption_current": 169, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 47, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010752376, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 18% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BB1 8RG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKBURN", "built_form": 2, "created_at": "2017-10-17 15:45:39.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Ottershaw Gardens", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.91, "quantity": "square metres"}, "party_wall_length": {"value": 7.87, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.91, "quantity": "square metres"}, "party_wall_length": {"value": 7.87, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 551, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 510, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2047, "space_heating_existing_dwelling": 7427}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 126, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100012487269, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "M34 6DR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2017-10-24 15:32:36.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15068}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 7 Holford Court", "address_line_2": "Bentley Road", "address_line_3": "Denton", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.88, "quantity": "square metres"}, "party_wall_length": {"value": 11.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.43, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 299, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 258, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1873, "space_heating_existing_dwelling": 4038}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 137, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 83027611, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HD4 7DS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 1, "created_at": "2017-10-16 19:25:11.000000", "door_count": 3, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "20, Hill Top Bank", "address_line_2": "Netherton", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 96.81, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 51.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 997, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 577, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2164, "impact_of_loft_insulation": -525, "impact_of_cavity_insulation": -6072, "space_heating_existing_dwelling": 18147}, "energy_consumption_current": 325, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 127, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100031202947, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NN8 3TJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLINGBOROUGH", "built_form": 4, "created_at": "2017-10-13 14:10:45.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17663}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "80, Kiln Way", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 46.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 417, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 360, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 5, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.9, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2017, "space_heating_existing_dwelling": 6534}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 59, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10012006170, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE65 5NP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "DERBY", "built_form": 4, "created_at": "2017-09-15 22:10:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 192, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 24 Lynmouth House", "address_line_2": "Welland Road", "address_line_3": "Hilton", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.05, "quantity": "metres"}}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.52, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 62.28, "quantity": "square metres"}, "party_wall_length": {"value": 14.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 259, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 198, "currency": "GBP"}, "hot_water_cost_current": {"value": 272, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 272, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2697, "impact_of_loft_insulation": -462, "space_heating_existing_dwelling": 2307}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 241, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100012485043, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "OL6 6TH", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHTON-UNDER-LYNE", "built_form": 3, "created_at": "2017-09-15 13:33:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2310, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 4 Holly Bank", "address_line_2": "Currier Lane", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 35, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.38, "quantity": "square metres"}, "party_wall_length": {"value": 11.93, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 313, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": "Charging system linked to use of community heating, TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 207, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1725, "impact_of_solid_wall_insulation": -1406, "space_heating_existing_dwelling": 4069}, "energy_consumption_current": 301, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 202, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100040655793, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DT5 1JY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "PORTLAND", "built_form": 3, "created_at": "2017-09-15 22:44:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "4, St. Martins Road", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.7, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 35.7, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.55, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 5.55, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 502, "currency": "GBP"}, "hot_water_cost_current": {"value": 189, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 332, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 222, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2824, "space_heating_existing_dwelling": 8520}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 106, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10008315239, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E9 6AE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 6, "created_at": "2017-06-15 12:01:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "18-20, Sedgwick Street", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4, "quantity": "metres"}}, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.08, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 84, "quantity": "square metres"}, "party_wall_length": {"value": 24.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 161, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 161, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2143, "space_heating_existing_dwelling": 916}, "energy_consumption_current": 77, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 77, "environmental_impact_current": 87, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "B", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 13, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200004460785, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NR7 0WY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORWICH", "built_form": 1, "created_at": "2017-06-22 10:23:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0.8, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8575}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 0.2, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "10, Lynn Close", "address_line_2": "Thorpe St. Andrew", "assessment_type": "RdSAP", "completion_date": "2017-06-22", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 149, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 25.9, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.87, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 56.76, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1029, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 168, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 898, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": 65, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2773, "impact_of_loft_insulation": -179, "space_heating_existing_dwelling": 12434}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 125, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031520772, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG8 4DW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2017-10-16 10:35:36.000000", "door_count": 3, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "56, Bilborough Road", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 49.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 613, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 558, "currency": "GBP"}, "hot_water_cost_current": {"value": 149, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2881, "space_heating_existing_dwelling": 8356}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 119, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100110353927, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA23 3DT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WINDERMERE", "built_form": 4, "created_at": "2017-08-16 06:59:18.000000", "door_count": 1, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2706, "main_heating_category": 8, "main_heating_fraction": 1, "sap_main_heating_code": 422, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric underfloor heating", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "40a, Quarry Rigg", "address_line_2": "Bowness-on-Windermere", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 44, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 43.56, "quantity": "square metres"}, "party_wall_length": {"value": 11.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 443, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 56}], "co2_emissions_potential": 3.2, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1444, "space_heating_existing_dwelling": 4668}, "energy_consumption_current": 445, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 430, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100100580479, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CF47 9RU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MERTHYR TYDFIL", "built_form": 3, "created_at": "2017-06-15 14:45:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16212}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "33, Sycamore Road", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.14, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 39.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.61, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.51, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 559, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.6, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2100, "space_heating_existing_dwelling": 9100}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 104, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100061191747, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN12 6UD", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "TONBRIDGE", "built_form": 2, "created_at": "2017-09-28 17:32:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "69, Cogate Road", "address_line_2": "Paddock Wood", "assessment_type": "RdSAP", "completion_date": "2017-09-28", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 0, "unheated_corridor_length": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-09-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 551, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 350, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}], "co2_emissions_potential": 3.1, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 176, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 150, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 146, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1703, "space_heating_existing_dwelling": 5684}, "energy_consumption_current": 472, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 351, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100120551560, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 11% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "GL20 5DB", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "TEWKESBURY", "built_form": 2, "created_at": "2017-09-17 14:00:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 610, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "2, Station Lane", "assessment_type": "RdSAP", "completion_date": "2017-09-17", "inspection_date": "2017-09-15", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.1, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 47.66, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 527, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 328, "currency": "GBP"}, "hot_water_cost_current": {"value": 334, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 7, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 302, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 239, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 290, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2130, "space_heating_existing_dwelling": 6547}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 85, "calculation_software_version": "2.12r11", "energy_consumption_potential": 56, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10002652695, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN35 4QP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HASTINGS", "built_form": 2, "created_at": "2017-10-04 11:16:21.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, New Moorsite", "address_line_2": "Westfield", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 38, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 447, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 412, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2637, "impact_of_loft_insulation": -234, "space_heating_existing_dwelling": 7191}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 93, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10012046916, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE29 6JW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUNTINGDON", "built_form": 3, "created_at": "2017-10-10 15:03:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "9, The Shrubbery", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 76.38, "quantity": "square metres"}, "party_wall_length": {"value": 5.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 420, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 362, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1843, "space_heating_existing_dwelling": 6717}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 151, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100060416665, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "GU17 9BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBERLEY", "built_form": 4, "created_at": "2017-10-13 07:57:50.000000", "door_count": 3, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17546}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, The Glebe", "address_line_2": "Blackwater", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-09", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 10.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.2, "quantity": "square metres"}, "party_wall_length": {"value": 13.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.3, "quantity": "square metres"}, "party_wall_length": {"value": 9.82, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 3.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 608, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 484, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2685, "impact_of_loft_insulation": -461, "impact_of_cavity_insulation": -2309, "space_heating_existing_dwelling": 10537}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010714327, "roofs": [{"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PR3 1EH", "hot_water": {"description": "From main system, plus solar", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "PRESTON", "built_form": 2, "created_at": "2017-10-10 09:33:13", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8410}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "solar_water_heating_details": {"shower_types": 2, "solar_water_pump": 1, "store_volume_details_known": "N", "solar_panel_collector_pitch": 3, "solar_panel_collector_data_source": 1, "solar_panel_collector_orientation": 2, "solar_panel_collector_overshading": 1}, "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "5, Cambridge Drive", "address_line_2": "Garstang", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-09", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 35.34, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "300mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.92, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.73, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.17, "quantity": "square metres"}, "party_wall_length": {"value": 2.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.55, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 71, "solar_water_heating": "Y", "habitable_room_count": 3, "heating_cost_current": {"value": 730, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 93, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3005, "impact_of_loft_insulation": -496, "space_heating_existing_dwelling": 11253}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 112, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10002525966, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF5 3BN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2017-10-20 10:15:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "3, Lougher Close", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.77, "quantity": "square metres"}, "party_wall_length": {"value": 15.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 236, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1558, "space_heating_existing_dwelling": 2217}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 174, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 15044803, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN2 6JZ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NORTHAMPTON", "built_form": 4, "created_at": "2017-10-04 13:52:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 605, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Portable electric heaters assumed for most rooms", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "62, Balmoral Road", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-04", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 95, "transaction_type": 2, "conservatory_type": 2, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 16.06, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 37.85, "quantity": "square metres"}, "party_wall_length": {"value": 15.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.88, "quantity": "square metres"}, "party_wall_length": 4.6, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 12.88, "quantity": "square metres"}, "party_wall_length": 4.6, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 2206, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.9, "energy_rating_average": 60, "energy_rating_current": 16, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 470, "currency": "GBP"}, "hot_water_cost_current": {"value": 314, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 609, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 1192, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 1119, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 1039, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 1194, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2002, "impact_of_loft_insulation": -1075, "impact_of_solid_wall_insulation": -4294, "space_heating_existing_dwelling": 14492}, "energy_consumption_current": 547, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 98, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "G", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 93, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200000959576, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Some secondary glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 36% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TN12 5NA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "TONBRIDGE", "built_form": 2, "created_at": "2017-10-18 18:33:27.000000", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 938}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "162, Bells Farm Road", "address_line_2": "East Peckham", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-18", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.62, "quantity": "square metres"}, "party_wall_length": {"value": 3.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.84, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 23.99, "wall_dry_lined": "N", "wall_thickness": 190, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 17.27, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 8, "roof_construction": 4, "wall_construction": 5, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 21.12, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 8, "roof_construction": 4, "wall_construction": 5, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 20.7, "quantity": "square metres"}, "party_wall_length": {"value": 3.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 917, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 582, "currency": "GBP"}, "hot_water_cost_current": {"value": 184, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 54, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 36}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 37}, {"sequence": 4, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 37}, {"sequence": 5, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 38}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 38}, {"sequence": 7, "typical_saving": {"value": 193, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 48}, {"sequence": 8, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 9, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 10, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 62}, {"sequence": 11, "typical_saving": {"value": 602, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 43, "environmental_impact_rating": 37}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3111, "impact_of_loft_insulation": -537, "impact_of_cavity_insulation": -1518, "space_heating_existing_dwelling": 15476}, "energy_consumption_current": 296, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "2.13r12", "energy_consumption_potential": 19, "environmental_impact_current": 32, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100021874461, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW16 5DX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-23 16:22:37.000000", "door_count": 2, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17760}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "20, Nettlewood Road", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.62, "quantity": "square metres"}, "party_wall_length": {"value": 15.27, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 41.62, "quantity": "square metres"}, "party_wall_length": {"value": 15.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 570, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 359, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 145, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2158, "impact_of_loft_insulation": -811, "impact_of_solid_wall_insulation": -2844, "space_heating_existing_dwelling": 8882}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 64, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100120679488, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WR9 8HP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "DROITWICH", "built_form": 2, "created_at": "2017-10-03 11:59:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "44, Albert Street", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-10-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.02, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 35.02, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 876, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 412, "currency": "GBP"}, "hot_water_cost_current": {"value": 186, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 350, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 134, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 160, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2721, "impact_of_solid_wall_insulation": -4846, "space_heating_existing_dwelling": 10542}, "energy_consumption_current": 395, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100021151812, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N22 7AH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-03 10:05:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15841}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "58, Albert Road", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-10-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 5.13, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 6.8}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.22, "quantity": "square metres"}, "party_wall_length": {"value": 21.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 362, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.1, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 101, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2006, "impact_of_solid_wall_insulation": -1976, "space_heating_existing_dwelling": 7796}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 168, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090477734, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO2 8SQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 2, "created_at": "2017-10-28 15:07:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4059}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "11a, Stalin Road", "assessment_type": "RdSAP", "completion_date": "2017-10-28", "inspection_date": "2017-10-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.96, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 301, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 243, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1518, "space_heating_existing_dwelling": 3582}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 187, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100062177723, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO21 2SJ", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BOGNOR REGIS", "built_form": 2, "created_at": "2017-10-16 15:22:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "39, Nyewood Lane", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 0.95}, "total_floor_area": 21, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.413, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 260, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "total_floor_area": {"value": 21.01, "quantity": "square metres"}, "party_wall_length": {"value": 11.23, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 252, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 82, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 115, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 112, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 144, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 829, "impact_of_cavity_insulation": -534, "space_heating_existing_dwelling": 1607}, "energy_consumption_current": 374, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "2.13r12", "energy_consumption_potential": 272, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100030335190, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE73 6RD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 4, "created_at": "2017-05-16 14:19:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "43a, Maple Drive", "address_line_2": "Chellaston", "assessment_type": "RdSAP", "completion_date": "2017-05-16", "inspection_date": "2017-05-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.86, "quantity": "square metres"}, "party_wall_length": {"value": 15.13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.45, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 250, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 225, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1635, "space_heating_existing_dwelling": 2871}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 151, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE7 7AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-06-21 10:11:29.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "121c Charlton Church Lane", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1, "quantity": "metres"}}, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": {"value": 38.82, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.57, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 3, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 52.36, "quantity": "square metres"}, "party_wall_length": {"value": 8.67, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.75, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 507, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 507, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 1, "percent_draughtproofed": 100, "co2_emissions_potential": 2.5, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2137, "impact_of_loft_insulation": -156, "space_heating_existing_dwelling": 3845}, "energy_consumption_current": 156, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 156, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 32133774, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B70 6TY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEST BROMWICH", "built_form": 2, "created_at": "2017-09-17 10:46:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "47, St. Christopher Close", "assessment_type": "RdSAP", "completion_date": "2017-09-17", "inspection_date": "2017-09-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.56, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 34.56, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 499, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 444, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1990, "space_heating_existing_dwelling": 7748}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 115, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10002501076, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN38 0FL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. LEONARDS-ON-SEA", "built_form": 2, "created_at": "2017-06-20 17:52:25.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 Heather Court", "address_line_2": "Arbourvale", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-03-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 1, "unheated_corridor_length": 0}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 59, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 222, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 224, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1844, "space_heating_existing_dwelling": 2118}, "energy_consumption_current": 130, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 126, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 25083916, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "MK46 4BL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OLNEY", "built_form": 4, "created_at": "2017-06-16 16:53:30", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8643}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "45, Midland Road", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-16", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 94, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.1, "quantity": "square metres"}, "party_wall_length": {"value": 17, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 45.77, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.56, "quantity": "square metres"}, "party_wall_length": {"value": 3.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 907, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 584, "currency": "GBP"}, "hot_water_cost_current": {"value": 201, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 159, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3574, "impact_of_loft_insulation": -1363, "impact_of_solid_wall_insulation": -4657, "space_heating_existing_dwelling": 12746}, "energy_consumption_current": 319, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 117, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 25025921, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "MK3 5LH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MILTON KEYNES", "built_form": 1, "created_at": "2017-05-17 23:49:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1139}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Thirsk Gardens", "address_line_2": "Bletchley", "assessment_type": "RdSAP", "completion_date": "2017-05-17", "inspection_date": "2017-05-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2017-05-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.88, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 52.88, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 31.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 889, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 608, "currency": "GBP"}, "hot_water_cost_current": {"value": 200, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 235, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 264, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2934, "impact_of_loft_insulation": -576, "space_heating_existing_dwelling": 12225}, "energy_consumption_current": 290, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061728731, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN16 3NG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LITTLEHAMPTON", "built_form": 4, "created_at": "2017-08-16 20:22:30.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15100}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Wakehurst Place", "address_line_2": "Rustington", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.85, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 35.82, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 311, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2737, "space_heating_existing_dwelling": 4295}, "energy_consumption_current": 168, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 49, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100120941863, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "access_issues": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX18 3UQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARTERTON", "built_form": 4, "created_at": "2017-06-19 12:02:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 16455}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Lyneham Close", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.304, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.953, "quantity": "square metres"}, "party_wall_length": {"value": 13.348, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.872, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.296, "quantity": "metres"}, "total_floor_area": {"value": 42.953, "quantity": "square metres"}, "party_wall_length": {"value": 13.348, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.872, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 599, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 533, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2846, "space_heating_existing_dwelling": 8394}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10093028110, "roofs": [{"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 59% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SS16 4TG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BASILDON", "built_form": 2, "created_at": "2017-09-16 13:47:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17836}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 10 Miriam Court", "address_line_2": "High Road", "address_line_3": "Vange", "assessment_type": "RdSAP", "completion_date": "2017-09-16", "inspection_date": "2017-09-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2, "quantity": "metres"}}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-09-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.4, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 330, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 41.45, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 59, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 178, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.9, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 179, "currency": "GBP"}, "hot_water_cost_current": {"value": 65, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1405, "space_heating_existing_dwelling": 1382}, "energy_consumption_current": 127, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 85, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100040770619, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH6 5DS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOURNEMOUTH", "built_form": 1, "created_at": "2017-08-16 12:26:27.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31, Stamford Road", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 44.1, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1016, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 973, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 6, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 56}], "co2_emissions_potential": 4.2, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3624, "impact_of_loft_insulation": -3446, "space_heating_existing_dwelling": 13987}, "energy_consumption_current": 325, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 219, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120798412, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"access_issues": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX16 9NZ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BANBURY", "built_form": 3, "created_at": "2017-10-23 11:37:31.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "6 Leighsanne Court", "address_line_2": "Mewburn Road", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-16", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.23}, "total_floor_area": 35, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.7736, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 31.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.47, "quantity": "square metres"}, "party_wall_length": {"value": 1.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 470, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 189, "currency": "GBP"}, "hot_water_cost_current": {"value": 316, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 251, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 201, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 179, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2352, "impact_of_cavity_insulation": -2874, "space_heating_existing_dwelling": 5289}, "energy_consumption_current": 682, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 355, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 115, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 2465063712, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LE4 2DT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2017-06-16 16:36:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "145, Halifax Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 8, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 6.8, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 5.26, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.11, "quantity": "square metres"}, "party_wall_length": {"value": 7.53, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 42.11, "quantity": "square metres"}, "party_wall_length": {"value": 7.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 829, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 130, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 592, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2275, "impact_of_loft_insulation": -401, "impact_of_cavity_insulation": -3395, "space_heating_existing_dwelling": 13545}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 133, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200003333586, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "YO21 1TY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "WHITBY", "built_form": 4, "created_at": "2017-06-17 08:15:52.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 4, "main_heating_number": 1, "main_heating_control": 2205, "main_heating_category": 4, "main_heating_fraction": 1, "sap_main_heating_code": 211, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Ground source heat pump, radiators, electric", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Bartons Row", "address_line_2": "Egton", "assessment_type": "RdSAP", "completion_date": "2017-06-17", "inspection_date": "2017-06-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4, 7], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.22, "quantity": "square metres"}, "party_wall_length": {"value": 14.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 29.22, "quantity": "square metres"}, "party_wall_length": {"value": 14.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 15.12, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 932, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 117, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and at least two room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 584, "currency": "GBP"}, "hot_water_cost_current": {"value": 242, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 80}, {"sequence": 6, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 89}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 152, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2645, "impact_of_loft_insulation": -204, "impact_of_solid_wall_insulation": -3731, "space_heating_existing_dwelling": 12130}, "energy_consumption_current": 293, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 120, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45131306, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR3 3AY", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-06-02 07:52:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 20, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "28 Australia Tower", "assessment_type": "RdSAP", "completion_date": "2017-06-02", "inspection_date": "2017-02-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 5, "heat_loss_corridor": 2, "unheated_corridor_length": 6.4}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-06-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.3, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 180, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.2, "quantity": "square metres"}, "party_wall_length": {"value": 9.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 409, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 333, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 96}], "co2_emissions_potential": 2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2234, "impact_of_solid_wall_insulation": -507, "space_heating_existing_dwelling": 4609}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 185, "environmental_impact_current": 95, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 96, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 42048545, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH45 5AJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 4, "created_at": "2017-09-18 10:52:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Greenbank Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 30.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 595, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 409, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1874, "impact_of_solid_wall_insulation": -2017, "space_heating_existing_dwelling": 7437}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 1775079938, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PO1 2JR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PORTSMOUTH", "built_form": 1, "created_at": "2017-09-16 14:46:40.000000", "door_count": 1, "glazed_area": 2, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8422}], "immersion_heating_type": "NA", "secondary_heating_type": 613, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "1 Capstan House", "address_line_2": "Tower Street", "assessment_type": "RdSAP", "completion_date": "2017-09-16", "inspection_date": "2017-09-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 126, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2017-09-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 75.41, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 41.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 50.51, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.72, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 577, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 158, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 513, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a385", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2298, "space_heating_existing_dwelling": 9503}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 136, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 46070208, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E16 4PR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-06-16 15:19:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "114, Star Lane", "assessment_type": "RdSAP", "completion_date": "2017-06-16", "inspection_date": "2017-06-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 33.1, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 33.1, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 351, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 351, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.9, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1951, "impact_of_loft_insulation": -208, "space_heating_existing_dwelling": 5027}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 167, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 90061682, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DY8 5YW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOURBRIDGE", "built_form": 4, "created_at": "2017-08-17 21:11:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5929}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Brook Street", "address_line_2": "Wordsley", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 241, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.81, "quantity": "square metres"}, "party_wall_length": {"value": 8.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 36.95, "quantity": "square metres"}, "party_wall_length": {"value": 18.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.56, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 25.38, "quantity": "square metres"}, "party_wall_length": {"value": 16.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 749, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 426, "currency": "GBP"}, "hot_water_cost_current": {"value": 201, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3571, "impact_of_loft_insulation": -219, "impact_of_solid_wall_insulation": -4948, "space_heating_existing_dwelling": 11732}, "energy_consumption_current": 285, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100010019601, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CH2 1RQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTER", "built_form": 4, "created_at": "2017-10-13 08:48:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "4, Marl Heys", "address_line_2": "Upton", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 43, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.49, "quantity": "square metres"}, "party_wall_length": {"value": 11.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.92, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 380, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 0.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1598, "impact_of_loft_insulation": -461, "space_heating_existing_dwelling": 5891}, "energy_consumption_current": 296, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 106, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090372274, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SS8 7QS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CANVEY ISLAND", "built_form": 1, "created_at": "2017-04-13 18:31:02.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16327}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "26, Chapman Road", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.23, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 32.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 398, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 75, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 0.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1730, "impact_of_cavity_insulation": -1363, "space_heating_existing_dwelling": 7875}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "1.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100023279872, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE7 8EP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-16 21:16:54.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "28 Heathwood Gardens", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 68.35, "quantity": "square metres"}, "party_wall_length": {"value": 22.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 676, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 542, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.0, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 101, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1980, "impact_of_loft_insulation": -5540, "impact_of_solid_wall_insulation": -3016, "space_heating_existing_dwelling": 11632}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 253, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100070137045, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CV12 8HG", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BEDWORTH", "built_form": 2, "created_at": "2017-08-13 09:14:21.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Barton Road", "assessment_type": "RdSAP", "completion_date": "2017-08-13", "inspection_date": "2017-08-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-08-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.41, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 636, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 466, "currency": "GBP"}, "hot_water_cost_current": {"value": 325, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 91, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 192, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4391, "space_heating_existing_dwelling": 7857}, "energy_consumption_current": 337, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "1.0.x", "energy_consumption_potential": 105, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 5103392, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NW3 2BE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2017-07-15 17:34:12.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17644}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "70 Haverstock Hill", "assessment_type": "RdSAP", "completion_date": "2017-07-15", "inspection_date": "2017-07-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 11.92, "quantity": "metres"}}, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 28.608, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.93, "quantity": "square metres"}, "party_wall_length": {"value": 16.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 5.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 570, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 30, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 218, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1838, "impact_of_solid_wall_insulation": -4521, "space_heating_existing_dwelling": 9311}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 20, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 32112006, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B70 8NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEST BROMWICH", "built_form": 3, "created_at": "2017-10-13 19:52:41.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 5, "rooms_with_mixer_shower_no_bath": 5, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17814}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "119 Edward Street", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 129, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 19.38, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "L", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.54, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 36.54, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.9, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.06, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 5.5, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 650, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 655, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2960, "impact_of_loft_insulation": -1688, "space_heating_existing_dwelling": 11723}, "energy_consumption_current": 172, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 27, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 27} +{"uprn": 33039221, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TW15 2TS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHFORD", "built_form": 2, "created_at": "2017-07-17 22:42:05.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16616}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "62b, Church Road", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-13", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.991, "quantity": "metres"}}, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.498, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 15.32, "quantity": "square metres"}, "party_wall_length": {"value": 4.715, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.991, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 410, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 37.8, "quantity": "square metres"}, "party_wall_length": 2.118, "heat_loss_perimeter": {"value": 16.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 373, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 310, "currency": "GBP"}, "hot_water_cost_current": {"value": 63, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1378, "impact_of_loft_insulation": -1453, "space_heating_existing_dwelling": 5693}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 170, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 11002281, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN35 7AB", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "CLEETHORPES", "built_form": 2, "created_at": "2017-04-14 17:10:28.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Savings Advice Ltd", "address_line_2": "44 Grimsby Road", "assessment_type": "RdSAP", "completion_date": "2017-04-14", "inspection_date": "2017-04-13", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 162, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.04, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.75, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 40.55, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 20.27, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.67, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 2086, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1212, "currency": "GBP"}, "hot_water_cost_current": {"value": 346, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 372, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 435, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 63}], "co2_emissions_potential": 5.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 52, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 99, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 93}, {"sequence": 3, "typical_saving": {"value": 525, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 55}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5353, "impact_of_loft_insulation": -8049, "impact_of_cavity_insulation": -2651, "impact_of_solid_wall_insulation": -6827, "space_heating_existing_dwelling": 32481}, "energy_consumption_current": 430, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 189, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100031431751, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NG21 9BD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANSFIELD", "built_form": 2, "created_at": "2017-06-15 15:20:41.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16400}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Greendale Crescent", "address_line_2": "Clipstone Village", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.21, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 37.21, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 620, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 598, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2761, "space_heating_existing_dwelling": 10838}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 168, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10013699876, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH7 4HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MOLD", "built_form": 1, "created_at": "2017-06-14 15:26:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17187}], "immersion_heating_type": "NA", "secondary_heating_type": 694, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "The Lodge", "address_line_2": "Corwen Road", "address_line_3": "Pontblyddyn", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.25, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 620, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 280, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 82}, {"sequence": 6, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 115, "environmental_impact_rating": 107}], "co2_emissions_potential": -0.5, "energy_rating_potential": 115, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2390, "impact_of_solid_wall_insulation": -4697, "space_heating_existing_dwelling": 10490}, "energy_consumption_current": 358, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": -131, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 107, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 88, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W2 1BS", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-06-14 08:56:46.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat BA", "address_line_2": "349a Edgware Road", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-13", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 31.04, "quantity": "square metres"}, "party_wall_length": {"value": 17.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.81, "quantity": "metres"}, "total_floor_area": {"value": 11.34, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 335, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.9, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1419, "impact_of_solid_wall_insulation": -2306, "space_heating_existing_dwelling": 6419}, "energy_consumption_current": 347, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 249, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100021395388, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 5% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM7 0NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROMFORD", "built_form": 2, "created_at": "2017-04-19 23:38:17.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "481, Rush Green Road", "assessment_type": "RdSAP", "completion_date": "2017-04-19", "inspection_date": "2017-04-13", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.65, "quantity": "square metres"}, "party_wall_length": {"value": 4.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 25.65, "quantity": "square metres"}, "party_wall_length": {"value": 4.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.52, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.81, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 13.81, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 5, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 982, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 723, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.5, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1993, "impact_of_loft_insulation": -2449, "impact_of_cavity_insulation": -3065, "impact_of_solid_wall_insulation": -1954, "space_heating_existing_dwelling": 15073}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 143, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 38096226, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L25 3RA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2017-07-17 12:13:59.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10577}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Lulworth Road", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 8, "conservatory_type": 4, "heated_room_count": 5, "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 9.66, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 9.15, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 45.1, "quantity": "square metres"}, "party_wall_length": {"value": 7.07, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 45.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "150mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 703, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 562, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2236, "impact_of_cavity_insulation": -3065, "space_heating_existing_dwelling": 12803}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 117, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100022016089, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SE26 5EQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-04-18 14:22:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "9a, Venner Road", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 135, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.84, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.27, "quantity": "square metres"}, "party_wall_length": {"value": 22.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.91, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.84, "quantity": "metres"}, "total_floor_area": {"value": 67.27, "quantity": "square metres"}, "party_wall_length": {"value": 22.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 595, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 164, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 391, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2047, "impact_of_solid_wall_insulation": -4635, "space_heating_existing_dwelling": 10290}, "energy_consumption_current": 152, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 96, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 41231310, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PR8 5NA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "SOUTHPORT", "built_form": 2, "created_at": "2017-10-13 13:13:26.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "19, Upper Aughton Road", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.5, "quantity": "metres"}}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.225, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 5, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.8, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 284, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 249, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1941, "space_heating_existing_dwelling": 3714}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 193, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100021820110, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 27% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SW16 2XU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-10-16 10:08:21.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "30, Caroline Close", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 26.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.65, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 370, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 348, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1758, "impact_of_loft_insulation": -250, "space_heating_existing_dwelling": 5228}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 80, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100110779288, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS17 6LJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKTON-ON-TEES", "built_form": 4, "created_at": "2017-10-19 16:35:16.000000", "door_count": 1, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "19, Oxford Road", "address_line_2": "Thornaby", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 51.88, "quantity": "square metres"}, "party_wall_length": {"value": 20.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 516, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.8, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1731, "impact_of_loft_insulation": -5246, "impact_of_solid_wall_insulation": -2525, "space_heating_existing_dwelling": 10603}, "energy_consumption_current": 364, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 309, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 200002698733, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE13 1PT", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MELTON MOWBRAY", "built_form": 2, "created_at": "2017-10-09 12:21:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "Flat 31 Beck Mill Court", "address_line_2": "Beck Mill Street", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-03", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 38.04, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 38.04, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 4.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.96, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 606, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 444, "currency": "GBP"}, "hot_water_cost_current": {"value": 265, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 239, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 57}], "co2_emissions_potential": 4.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 292, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 305, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 158, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1916, "impact_of_loft_insulation": -505, "space_heating_existing_dwelling": 6846}, "energy_consumption_current": 348, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 298, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10002679624, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU19 5AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BAGSHOT", "built_form": 2, "created_at": "2017-10-14 11:47:47.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17119}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Flat", "address_line_2": "28, High Street", "assessment_type": "RdSAP", "completion_date": "2017-10-14", "inspection_date": "2017-10-13", "extensions_count": 3, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 174, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": {"value": 26.4, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 90.4, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 22.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 3, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 3.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 3.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 23.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 8, "roof_construction": 1, "wall_construction": 5, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 30.1, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 2013, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1838, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 39}], "co2_emissions_potential": 10, "energy_rating_potential": 49, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 138, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2894, "impact_of_loft_insulation": -5105, "impact_of_solid_wall_insulation": -2999, "space_heating_existing_dwelling": 30861}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 332, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 39, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100000031558, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE11 9TT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GATESHEAD", "built_form": 1, "created_at": "2017-04-18 18:41:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15169}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Festival Park Drive", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.06, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 46.06, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 538, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 479, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2198, "space_heating_existing_dwelling": 9079}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100050070650, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HU13 9HF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HESSLE", "built_form": 2, "created_at": "2017-10-19 12:28:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8643}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "36, Barnetby Road", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 531, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 437, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2645, "impact_of_loft_insulation": -252, "space_heating_existing_dwelling": 8059}, "energy_consumption_current": 242, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 98, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100020254302, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 53% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA15 8RR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SIDCUP", "built_form": 2, "created_at": "2017-07-18 11:32:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2041}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "17, Leechcroft Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.77, "quantity": "square metres"}, "party_wall_length": {"value": 9.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 29.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 679, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 349, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 210, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2601, "impact_of_loft_insulation": -620, "impact_of_solid_wall_insulation": -4055, "space_heating_existing_dwelling": 10851}, "energy_consumption_current": 316, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 67, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10002239945, "roofs": [{"description": {"value": "Pitched, 400 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CW3 9BW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CREWE", "built_form": 1, "created_at": "2017-09-18 12:59:23.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9897}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Old Road", "address_line_2": "Wrinehill", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 155, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 77.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 35.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 77.28, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 568, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 571, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 84}], "co2_emissions_potential": 2.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2668, "space_heating_existing_dwelling": 9917}, "energy_consumption_current": 126, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 81, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 29, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 29} +{"uprn": 100060043147, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TN38 0RT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. LEONARDS-ON-SEA", "built_form": 2, "created_at": "2017-10-18 18:43:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17013}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Charles Road West", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 122, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.67, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 26.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 62.03, "quantity": "square metres"}, "party_wall_length": {"value": 8.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1010, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 145, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 968, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 93, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": 80, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 61}], "co2_emissions_potential": 4.1, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2141, "impact_of_loft_insulation": -5172, "space_heating_existing_dwelling": 16237}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 177, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 3455086922, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST6 7NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 1, "created_at": "2017-10-18 17:45:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Sherratt Street", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-18", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.28, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.29, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.02, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.71, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1094, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 578, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2199, "impact_of_loft_insulation": -3185, "impact_of_cavity_insulation": -5484, "space_heating_existing_dwelling": 20812}, "energy_consumption_current": 368, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 132, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200002586864, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 10% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "HR1 2QU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HEREFORD", "built_form": 4, "created_at": "2017-10-19 13:32:09.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16212}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "51, Harold Street", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-18", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.71, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 19.71, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.04, "quantity": "square metres"}, "party_wall_length": {"value": 3.08, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 14.31, "quantity": "square metres"}, "party_wall_length": {"value": 3.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.51, "quantity": "square metres"}, "party_wall_length": {"value": 1.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 622, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 415, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 92, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2082, "impact_of_solid_wall_insulation": -3422, "space_heating_existing_dwelling": 9895}, "energy_consumption_current": 256, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.13r13", "energy_consumption_potential": 84, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 64039981, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF63 1JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARRY", "built_form": 4, "created_at": "2017-06-19 10:47:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Church Road", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.03, "quantity": "square metres"}, "party_wall_length": {"value": 15.66, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 34.03, "quantity": "square metres"}, "party_wall_length": {"value": 15.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 566, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 376, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1977, "impact_of_loft_insulation": -307, "impact_of_solid_wall_insulation": -3209, "space_heating_existing_dwelling": 8372}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 70, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 20, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100120906574, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX13 6BL", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ABINGDON", "built_form": 1, "created_at": "2017-09-19 08:20:58.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1852}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "27, Long Furlong Road", "address_line_2": "Sunningwell", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-09-18", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.41, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 25.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 10.11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 5.03, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 690, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 446, "currency": "GBP"}, "hot_water_cost_current": {"value": 207, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3195, "impact_of_loft_insulation": -260, "space_heating_existing_dwelling": 9642}, "energy_consumption_current": 315, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 98, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 12076634, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W5 1LZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-08-31 08:42:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "54, Harrow View Road", "assessment_type": "RdSAP", "completion_date": "2017-08-31", "inspection_date": "2017-08-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 33.64, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.74, "quantity": "square metres"}, "party_wall_length": {"value": 7.99, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 48.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1190, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 521, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2977, "impact_of_loft_insulation": -263, "impact_of_solid_wall_insulation": -5643, "space_heating_existing_dwelling": 22224}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "1.0.x", "energy_consumption_potential": 86, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100120530832, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 35% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "GL5 2DN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STROUD", "built_form": 3, "created_at": "2017-08-21 19:53:43", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1 Glyn Terrace", "address_line_2": "Middle Road", "address_line_3": "Thrupp", "assessment_type": "RdSAP", "completion_date": "2017-08-21", "inspection_date": "2017-08-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.14, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.27, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.93, "quantity": "metres"}, "total_floor_area": {"value": 26.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 15.92, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.92, "quantity": "square metres"}, "party_wall_length": {"value": 3.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.93, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.21, "quantity": "metres"}, "total_floor_area": {"value": 15.92, "quantity": "square metres"}, "party_wall_length": {"value": 3.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 35, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1383, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 614, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 336, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 168, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2236, "impact_of_loft_insulation": -2153, "impact_of_solid_wall_insulation": -5273, "space_heating_existing_dwelling": 20616}, "energy_consumption_current": 429, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 125, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 20, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100071545006, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 68% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TF9 2JA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARKET DRAYTON", "built_form": 1, "created_at": "2017-07-18 16:12:34", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0.8, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0.2, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16454}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Warrant Bungalow", "address_line_2": "Warrant Road", "address_line_3": "Tern Hill", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 189, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 144.59, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 46.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.09, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 68, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1162, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1039, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 87}], "co2_emissions_potential": 2.3, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 93, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2170, "impact_of_loft_insulation": -484, "space_heating_existing_dwelling": 21024}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 80, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100040824463, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH17 7DW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 2, "created_at": "2017-04-18 14:18:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "secondary_heating_type": 613, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "81, Petersham Road", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.38, "quantity": "square metres"}, "party_wall_length": {"value": 8.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 39.14, "quantity": "square metres"}, "party_wall_length": {"value": 7.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.66, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.07, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 538, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2193, "impact_of_loft_insulation": -815, "space_heating_existing_dwelling": 9021}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 87, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10096902803, "roofs": [{"description": "Pitched, limited insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Pitched, insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Granite or whinstone, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 42% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PL27 7UL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WADEBRIDGE", "built_form": 1, "created_at": "2017-05-23 19:29:21", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15012}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "The Linhay", "address_line_2": "Engollan, St. Eval", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 135, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.02, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 99.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 53.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "50mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "50mm"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1182, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.5, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 609, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 419, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2966, "impact_of_solid_wall_insulation": -8735, "space_heating_existing_dwelling": 24353}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 17, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "F", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100121040172, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SP2 8AQ", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SALISBURY", "built_form": 3, "created_at": "2017-05-18 19:44:35.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.7, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.3, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "64, Chichester Close", "assessment_type": "RdSAP", "completion_date": "2017-05-18", "inspection_date": "2017-05-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.05, "quantity": "square metres"}, "party_wall_length": {"value": 4.81, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 38.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.82, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 5.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.9, "quantity": "square metres"}, "party_wall_length": 1.68, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1026, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 501, "currency": "GBP"}, "hot_water_cost_current": {"value": 260, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 6, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 8, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 251, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 208, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 243, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3465, "impact_of_cavity_insulation": -3291, "space_heating_existing_dwelling": 11265}, "energy_consumption_current": 478, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 140, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100051186399, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 35% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BD13 5HF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRADFORD", "built_form": 1, "created_at": "2017-10-18 20:20:24.000000", "door_count": 4, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15426}], "immersion_heating_type": "NA", "secondary_heating_type": 613, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "12, Lees Close", "address_line_2": "Cullingworth", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 218, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 9, "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 112.52, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 46.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 105.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 46.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "150mm"}], "low_energy_lighting": 35, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1067, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 168, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1019, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 170, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 4.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 101, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3028, "impact_of_loft_insulation": -1426, "space_heating_existing_dwelling": 20876}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 123, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 52, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100011708887, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WN7 5LR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEIGH", "built_form": 2, "created_at": "2017-09-21 11:18:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Glover Street", "assessment_type": "RdSAP", "completion_date": "2017-09-21", "inspection_date": "2017-09-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 6.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.73, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 6.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.73, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 815, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 779, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.3, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2173, "impact_of_loft_insulation": -3982, "space_heating_existing_dwelling": 12072}, "energy_consumption_current": 288, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 198, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 77094952, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M16 8HP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 2, "created_at": "2017-08-21 22:03:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "58 Manley Road", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.31, "quantity": "metres"}}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 32.2703, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.13, "quantity": "metres"}, "total_floor_area": {"value": 49.3, "quantity": "square metres"}, "party_wall_length": {"value": 4.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 489, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 228, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 220, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1766, "impact_of_solid_wall_insulation": -4828, "space_heating_existing_dwelling": 8203}, "energy_consumption_current": 302, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 15, "calculation_software_version": 9.92, "energy_consumption_potential": 145, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 46019787, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "E13 8LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-09-18 18:18:27.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9896}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "86, Cumberland Road", "assessment_type": "RdSAP", "completion_date": "2017-09-18", "inspection_date": "2017-09-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.649, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.791, "quantity": "square metres"}, "party_wall_length": {"value": 15.748, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.549, "quantity": "metres"}, "total_floor_area": {"value": 43.882, "quantity": "square metres"}, "party_wall_length": {"value": 15.748, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.146, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 140, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.592, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.814, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 602, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 126, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 412, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2760, "impact_of_solid_wall_insulation": -3695, "space_heating_existing_dwelling": 10750}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 76, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 5075503, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "System built, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NW3 2JE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-08-21 08:24:58.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "65b, Mansfield Road", "assessment_type": "RdSAP", "completion_date": "2017-08-21", "inspection_date": "2017-08-18", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.58, "quantity": "square metres"}, "party_wall_length": {"value": 18.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.82, "quantity": "square metres"}, "party_wall_length": {"value": 3.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 305, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 290, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1871, "space_heating_existing_dwelling": 4158}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "9.0.0", "energy_consumption_potential": 172, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100040890958, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true", "narrow_cavities": "true"}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TA6 5BH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIDGWATER", "built_form": 4, "created_at": "2017-04-18 15:54:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Loxleigh Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-18", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 33.8, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.4, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 17.4, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 904, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 708, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 45, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1681, "impact_of_loft_insulation": -4165, "impact_of_solid_wall_insulation": -3610, "space_heating_existing_dwelling": 16004}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 129, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100000013773, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Some double glazing", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE9 7AF", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "GATESHEAD", "built_form": 4, "created_at": "2017-10-24 14:17:52.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "52, Acomb Court", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 5, "heat_loss_corridor": 2, "unheated_corridor_length": 6.4}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.72, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 47.04, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "150mm"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 291, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 103, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1574, "impact_of_solid_wall_insulation": -743, "space_heating_existing_dwelling": 3233}, "energy_consumption_current": 340, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "2.13r13", "energy_consumption_potential": 193, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100031512176, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG8 5QZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2017-06-20 18:20:48.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Ambleside Road", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-01-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 438, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 397, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2681, "space_heating_existing_dwelling": 5556}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 93, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100062038627, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To external air, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO19 6NX", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2017-07-17 16:08:08.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2703, "main_heating_category": 8, "main_heating_fraction": 0.7, "sap_main_heating_code": 424, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.3, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric underfloor heating", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 Meredith Towers", "address_line_2": "Tunstall Road", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-11", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 10.68}, "total_floor_area": 45, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 25.9524, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 180, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.33, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 1, "roof_construction": 3, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.76, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.88, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 768, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 768, "currency": "GBP"}, "hot_water_cost_current": {"value": 219, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 3.7, "energy_rating_potential": 36, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 219, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1620, "space_heating_existing_dwelling": 5183}, "energy_consumption_current": 487, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 487, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "F", "environmental_impact_potential": 41, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "F", "co2_emissions_current_per_floor_area": 82, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 48027438, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW19 8TL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-12 08:14:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15020}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "157, Florence Road", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 492, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 275, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 30, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 7, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 8, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2721, "impact_of_loft_insulation": -433, "impact_of_solid_wall_insulation": -2825, "space_heating_existing_dwelling": 8250}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 30, "calculation_software_version": "2.13r09", "energy_consumption_potential": 41, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100071000016, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B92 7BU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOLIHULL", "built_form": 4, "created_at": "2017-10-11 16:49:25.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "18, Marsland Road", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.18, "quantity": "square metres"}, "party_wall_length": {"value": 15.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 45.18, "quantity": "square metres"}, "party_wall_length": {"value": 15.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 588, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 597, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2188, "impact_of_loft_insulation": -2868, "space_heating_existing_dwelling": 9694}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 142, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 5008002, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Full secondary glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 8% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "EC1R 4PT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-05-12 14:18:22.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 51 Rosebery Square West", "address_line_2": "Rosebery Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-12", "inspection_date": "2017-05-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 5, "heat_loss_corridor": 2, "unheated_corridor_length": 6.63}, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.8955, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 120, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "total_floor_area": {"value": 81.53, "quantity": "square metres"}, "party_wall_length": {"value": 8.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 817, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 615, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}], "co2_emissions_potential": 3.4, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2146, "impact_of_loft_insulation": -5913, "impact_of_solid_wall_insulation": -5318, "space_heating_existing_dwelling": 14989}, "energy_consumption_current": 321, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 236, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 58, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100060460973, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO7 5TS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WATERLOOVILLE", "built_form": 3, "created_at": "2017-05-11 15:57:22.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Mountbatten Drive", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.04, "quantity": "square metres"}, "party_wall_length": {"value": 3.38, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 39.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.97, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 479, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1984, "impact_of_loft_insulation": -544, "space_heating_existing_dwelling": 6309}, "energy_consumption_current": 204, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 72, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100065038, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM7 0UL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROMFORD", "built_form": 3, "created_at": "2017-08-11 20:48:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Legon Avenue", "assessment_type": "RdSAP", "completion_date": "2017-08-11", "inspection_date": "2017-08-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.92, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.92, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 698, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 539, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1885, "impact_of_loft_insulation": -3120, "impact_of_cavity_insulation": -3337, "space_heating_existing_dwelling": 12835}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 124, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100021764291, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT2 5AX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KINGSTON UPON THAMES", "built_form": 4, "created_at": "2017-10-12 14:32:56.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1821}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 15 Canbury Court", "address_line_2": "Lower Ham Road", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 45.19, "quantity": "square metres"}, "party_wall_length": {"value": 15.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 257, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 33, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 166, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1625, "impact_of_solid_wall_insulation": -1581, "space_heating_existing_dwelling": 2745}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 112, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100061827245, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RH20 3BD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "PULBOROUGH", "built_form": 1, "created_at": "2017-09-22 14:22:55.000000", "door_count": 5, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 655}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Farthings", "address_line_2": "6, Brookside", "address_line_3": "Ashington", "assessment_type": "RdSAP", "completion_date": "2017-09-22", "inspection_date": "2017-09-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 128, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 7, "registration_date": "2017-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 59.01, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 31.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 912, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 612, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 232, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2829, "impact_of_loft_insulation": -741, "space_heating_existing_dwelling": 13422}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 101, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10033356911, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NP25 4SP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MONMOUTH", "built_form": 1, "created_at": "2017-05-23 06:42:41", "door_count": 1, "glazed_area": 2, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10170}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Whispers", "address_line_2": "Pentwyn Park", "address_line_3": "Penallt", "assessment_type": "RdSAP", "completion_date": "2017-05-23", "inspection_date": "2017-05-11", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 200, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-05-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 75.07, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.01, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.52, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 98.37, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 880, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 803, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "co2_emissions_potential": 4.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 101, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3003, "space_heating_existing_dwelling": 17733}, "energy_consumption_current": 142, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 96, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 31, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 28} +{"uprn": 100040831010, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH15 3EB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 1, "created_at": "2017-04-13 09:02:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17037}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "63, Simmonds Close", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-11", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.46, "quantity": "metres"}}, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.78, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 75.95, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 33.67, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 1, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 2.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 411, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 387, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.2, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1796, "impact_of_loft_insulation": -1781, "impact_of_cavity_insulation": -190, "space_heating_existing_dwelling": 5869}, "energy_consumption_current": 172, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["G"], "calculation_software_version": "9.0.0", "energy_consumption_potential": 163, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100070503229, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B28 0UN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2017-05-11 13:25:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Sandgate Road", "assessment_type": "RdSAP", "completion_date": "2017-05-11", "inspection_date": "2017-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.64, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 50.48, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1002, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 759, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 161, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 207, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2241, "impact_of_loft_insulation": -4675, "space_heating_existing_dwelling": 14474}, "energy_consumption_current": 323, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 173, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 310041133, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG4 8DL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 4, "created_at": "2017-04-11 13:48:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "54, Queens Road", "address_line_2": "Caversham", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.11, "quantity": "square metres"}, "party_wall_length": {"value": 17.83, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 35.81, "quantity": "square metres"}, "party_wall_length": {"value": 18.39, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 535, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 376, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2739, "impact_of_loft_insulation": -340, "impact_of_solid_wall_insulation": -3079, "space_heating_existing_dwelling": 9060}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 77, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100090052935, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB7 5DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}, "post_town": "ELY", "built_form": 2, "created_at": "2017-04-11 10:45:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 126, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Qua Fen Common", "address_line_2": "Soham", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 25.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 588, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 288, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 79}, {"sequence": 7, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 108, "environmental_impact_rating": 100}], "co2_emissions_potential": -0.2, "energy_rating_potential": 108, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2543, "impact_of_solid_wall_insulation": -3482, "space_heating_existing_dwelling": 9866}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": -87, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 100, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090252000, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 10% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SS15 5BA", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BASILDON", "built_form": 4, "created_at": "2017-04-12 08:45:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 604, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "92, Long Lynderswood", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 41.25, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 41.18, "quantity": "square metres"}, "party_wall_length": {"value": 14.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 895, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 581, "currency": "GBP"}, "hot_water_cost_current": {"value": 239, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 202, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 90}, {"sequence": 3, "typical_saving": {"value": 237, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3219, "impact_of_loft_insulation": -3795, "impact_of_cavity_insulation": -1912, "space_heating_existing_dwelling": 11457}, "energy_consumption_current": 391, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 139, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100060412932, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 77% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU17 9EY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBERLEY", "built_form": 2, "created_at": "2017-07-11 12:07:46.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "34, Thornfield Green", "address_line_2": "Blackwater", "assessment_type": "RdSAP", "completion_date": "2017-07-11", "inspection_date": "2017-07-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.74, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 44.39, "quantity": "square metres"}, "party_wall_length": {"value": 8.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 77, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 471, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2718, "space_heating_existing_dwelling": 7789}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 91, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 11017131, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DN32 9NT", "hot_water": {"description": "Gas multipoint", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "GRIMSBY", "built_form": 4, "created_at": "2017-10-11 16:57:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15770}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "69, Patrick Street", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.81, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.86, "quantity": "square metres"}, "party_wall_length": {"value": 18.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 44.38, "quantity": "square metres"}, "party_wall_length": {"value": 19.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.18, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.38, "quantity": "square metres"}, "party_wall_length": {"value": 3.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1193, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 909, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 91, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1650, "impact_of_loft_insulation": -4670, "impact_of_solid_wall_insulation": -5035, "space_heating_existing_dwelling": 18973}, "energy_consumption_current": 340, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 89, "calculation_software_version": "2.13r09", "energy_consumption_potential": 188, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100081072970, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SL0 0EB", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "IVER", "built_form": 1, "created_at": "2017-04-11 16:43:18.000000", "door_count": 5, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 126, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Mansfield Farm", "address_line_2": "Slough Road", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 254, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "false", "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 124.06, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 48.91, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 125.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 52.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.76, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2231, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 17, "energy_rating_average": 60, "energy_rating_current": 32, "lighting_cost_current": {"value": 210, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 5, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1034, "currency": "GBP"}, "hot_water_cost_current": {"value": 310, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 801, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": 90, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 346, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 597, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 71}], "co2_emissions_potential": 5.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 120, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 90}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2224, "impact_of_solid_wall_insulation": -14849, "space_heating_existing_dwelling": 40486}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "2.11r09", "energy_consumption_potential": 56, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 23, "current_energy_efficiency_band": "F", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 5140262, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW6 4AA", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-04-12 13:08:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "197 Belsize Road", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.3, "quantity": "metres"}}, "total_floor_area": 21, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.52, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 21.32, "quantity": "square metres"}, "party_wall_length": {"value": 4.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 114, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.7, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 21, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 114, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1699, "space_heating_existing_dwelling": 375}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 194, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 766040008, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 82% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HP22 4HS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "AYLESBURY", "built_form": 1, "created_at": "2017-10-13 15:29:50.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 125, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "12, The Pightle", "address_line_2": "Oving", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 137, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 37.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 66.17, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 714, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 496, "currency": "GBP"}, "hot_water_cost_current": {"value": 177, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2983, "impact_of_loft_insulation": -463, "space_heating_existing_dwelling": 11960}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 83, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 200001577831, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST9 0JR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2017-10-09 06:59:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "362, Ash Bank Road", "address_line_2": "Werrington", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-07", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 430, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 34.69, "quantity": "square metres"}, "party_wall_length": {"value": 7.76, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 34.69, "quantity": "square metres"}, "party_wall_length": {"value": 7.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "100mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.71, "quantity": "square metres"}, "party_wall_length": {"value": 6.44, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 545, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 390, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1950, "impact_of_solid_wall_insulation": -3383, "space_heating_existing_dwelling": 9366}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 91, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100010209171, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CW7 1QQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WINSFORD", "built_form": 4, "created_at": "2017-10-26 09:33:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "65, Grampian Way", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.9, "quantity": "square metres"}, "party_wall_length": {"value": 11.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 40.3, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 515, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 494, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2236, "space_heating_existing_dwelling": 8779}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 124, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 148006083, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EN8 8RJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WALTHAM CROSS", "built_form": 2, "created_at": "2017-07-12 06:20:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 613, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "49, Dudley Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.519, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.221282, "quantity": "square metres"}, "party_wall_length": {"value": 9.551, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.091, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 434, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 318, "currency": "GBP"}, "hot_water_cost_current": {"value": 223, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3274, "space_heating_existing_dwelling": 5386}, "energy_consumption_current": 301, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 63, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10070707892, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TW9 4AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RICHMOND", "built_form": 2, "created_at": "2017-04-11 14:15:05.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "75, Mortlake Road", "assessment_type": "RdSAP", "completion_date": "2017-04-11", "inspection_date": "2017-04-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4, "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 597, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 570, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}], "co2_emissions_potential": 3.0, "energy_rating_potential": 59, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1976, "impact_of_loft_insulation": -4393, "impact_of_solid_wall_insulation": -309, "space_heating_existing_dwelling": 9636}, "energy_consumption_current": 355, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 326, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010492841, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LA3 1LX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MORECAMBE", "built_form": 1, "created_at": "2017-07-10 18:20:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8108}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "72, Oxcliffe Road", "address_line_2": "Heysham", "assessment_type": "RdSAP", "completion_date": "2017-07-10", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 33.56, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 555, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 454, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 48, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1906, "space_heating_existing_dwelling": 7851}, "energy_consumption_current": 285, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "9.0.0", "energy_consumption_potential": 117, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100070413222, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B32 4LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2017-10-11 14:47:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16986}], "immersion_heating_type": "NA", "secondary_heating_type": 607, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Hunnington Close", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 741, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 513, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1964, "impact_of_loft_insulation": -841, "impact_of_cavity_insulation": -3066, "space_heating_existing_dwelling": 12581}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF24 4RR", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2017-04-12 16:10:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat B", "address_line_2": "88 Mackintosh Place", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-10", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2, "quantity": "metres"}}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.2, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 2, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.71, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.34, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 474, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 192, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.7, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 232, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 217, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 158, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 918, "impact_of_solid_wall_insulation": -652, "space_heating_existing_dwelling": 3050}, "energy_consumption_current": 353, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 286, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10013441584, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH1 3RY", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BOURNEMOUTH", "built_form": 2, "created_at": "2017-05-10 13:58:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4a", "address_line_2": "17 Frances Road", "assessment_type": "RdSAP", "completion_date": "2017-05-10", "inspection_date": "2017-05-10", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.19, "quantity": "metres"}}, "total_floor_area": 61, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-05-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 32.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 17.022, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 29.08, "quantity": "square metres"}, "party_wall_length": 4.15, "heat_loss_perimeter": {"value": 14.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 275, "currency": "GBP"}, "hot_water_cost_current": {"value": 246, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 189, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 59}], "co2_emissions_potential": 2.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 258, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1809, "space_heating_existing_dwelling": 7651}, "energy_consumption_current": 498, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 276, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100100038082, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF14 3JR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2017-07-10 18:07:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "213, Whitchurch Road", "assessment_type": "RdSAP", "completion_date": "2017-07-10", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 71.73, "quantity": "square metres"}, "party_wall_length": {"value": 25.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 778, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 239, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 337, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2023, "impact_of_loft_insulation": -6099, "impact_of_solid_wall_insulation": -3155, "space_heating_existing_dwelling": 11964}, "energy_consumption_current": 345, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 114, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 64003939, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF62 5TR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARRY", "built_form": 2, "created_at": "2017-07-13 12:56:03.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17039}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "20, Friars Road", "assessment_type": "RdSAP", "completion_date": "2017-07-13", "inspection_date": "2017-07-10", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 145, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": {"value": 55.59, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 82.62, "quantity": "square metres"}, "party_wall_length": {"value": 8.67, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 6.29, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1337, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 126, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 683, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 443, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.8, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1995, "impact_of_loft_insulation": -2036, "impact_of_cavity_insulation": -2793, "impact_of_solid_wall_insulation": -1226, "space_heating_existing_dwelling": 26205}, "energy_consumption_current": 285, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 148, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 45107472, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SR5 5RA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2017-04-10 13:41:33", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Raleigh Square", "assessment_type": "RdSAP", "completion_date": "2017-04-10", "inspection_date": "2017-04-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 30}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.31, "quantity": "square metres"}, "party_wall_length": {"value": 5.84, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 29.31, "quantity": "square metres"}, "party_wall_length": {"value": 5.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.88, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 438, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1838, "space_heating_existing_dwelling": 6157}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010610566, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BB4 8HN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROSSENDALE", "built_form": 4, "created_at": "2017-08-10 20:45:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Hobson Street", "assessment_type": "RdSAP", "completion_date": "2017-08-10", "inspection_date": "2017-08-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 26.25, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.58, "quantity": "square metres"}, "party_wall_length": {"value": 17.76, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 36.58, "quantity": "square metres"}, "party_wall_length": {"value": 17.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.22, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1162, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 644, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2189, "impact_of_loft_insulation": -354, "impact_of_cavity_insulation": -1121, "impact_of_solid_wall_insulation": -1595, "space_heating_existing_dwelling": 21482}, "energy_consumption_current": 340, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 138, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 41071858, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "L20 9HZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOOTLE", "built_form": 4, "created_at": "2017-07-10 16:21:03.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Partington Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-10", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.25, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 39.85, "quantity": "square metres"}, "party_wall_length": {"value": 14.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.64, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 572, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 492, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2215, "impact_of_loft_insulation": -3372, "impact_of_solid_wall_insulation": -1511, "space_heating_existing_dwelling": 10032}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100110425522, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DH1 1PR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DURHAM", "built_form": 4, "created_at": "2017-07-10 14:45:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Roosevelt Road", "assessment_type": "RdSAP", "completion_date": "2017-07-10", "inspection_date": "2017-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.55, "quantity": "square metres"}, "party_wall_length": {"value": 5.17, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 42.75, "quantity": "square metres"}, "party_wall_length": {"value": 5.17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 504, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 464, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2130, "space_heating_existing_dwelling": 8319}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 107, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10034867435, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO14 3JW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2017-10-11 14:53:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 191, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 55 Sapphire Court", "address_line_2": "Ocean Way", "assessment_type": "RdSAP", "completion_date": "2017-10-11", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 5, "heat_loss_corridor": 2, "unheated_corridor_length": 1.2}, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.76, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 73.07, "quantity": "square metres"}, "party_wall_length": {"value": 20.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 131, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 131, "currency": "GBP"}, "hot_water_cost_current": {"value": 199, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1855, "space_heating_existing_dwelling": 756}, "energy_consumption_current": 130, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 117, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "B", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010178376, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 18% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CW8 1LY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHWICH", "built_form": 1, "created_at": "2017-10-10 20:06:18.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15445}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "6, Abbey Way", "address_line_2": "Hartford", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-10", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 972, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 880, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 61}], "co2_emissions_potential": 3.8, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2217, "impact_of_loft_insulation": -5808, "space_heating_existing_dwelling": 17569}, "energy_consumption_current": 319, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 99, "calculation_software_version": 9.92, "energy_consumption_potential": 214, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 11014952, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DN32 9PU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 4, "created_at": "2017-07-14 13:32:15.000000", "door_count": 2, "glazed_area": 5, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"orientation": 3, "window_area": {"value": 1.63, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"orientation": 3, "window_area": {"value": 0.571, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 7, "window_area": {"value": 1.482, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 7, "window_area": {"value": 1.467, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 3, "window_area": {"value": 1.768, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 7, "window_area": {"value": 1.666, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"orientation": 1, "window_area": {"value": 0.522, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 7, "window_area": {"value": 1.06, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "130, Willingham Street", "assessment_type": "RdSAP", "completion_date": "2017-07-14", "inspection_date": "2017-07-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.777, "sheltered_wall": "N", "wall_dry_lined": "Y", "wall_thickness": 280, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.686, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.718, "quantity": "square metres"}, "party_wall_length": {"value": 16.488, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.922, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.545, "quantity": "metres"}, "total_floor_area": {"value": 33.718, "quantity": "square metres"}, "party_wall_length": {"value": 16.488, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.922, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.223, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.445, "quantity": "square metres"}, "party_wall_length": {"value": 4.183, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.441, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.231, "quantity": "metres"}, "total_floor_area": {"value": 9.445, "quantity": "square metres"}, "party_wall_length": {"value": 4.183, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.441, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 721, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 409, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2161, "impact_of_solid_wall_insulation": -3725, "space_heating_existing_dwelling": 10442}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 77, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050073861, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HU13 9LR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "HESSLE", "built_form": 2, "created_at": "2017-07-10 15:14:23.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Kingston Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-10", "inspection_date": "2017-07-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.67, "quantity": "square metres"}, "party_wall_length": {"value": 6.75, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 31.19, "quantity": "square metres"}, "party_wall_length": {"value": 6.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.13, "quantity": "square metres"}, "party_wall_length": {"value": 3.43, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 872, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 546, "currency": "GBP"}, "hot_water_cost_current": {"value": 68, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 229, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 40, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1520, "impact_of_cavity_insulation": -715, "impact_of_solid_wall_insulation": -4330, "space_heating_existing_dwelling": 14773}, "energy_consumption_current": 348, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 128, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100091096226, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP14 1QY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOWMARKET", "built_form": 2, "created_at": "2017-10-13 06:37:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 1, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "34, Underhill", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 29.12, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "E"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64, "quantity": "square metres"}, "party_wall_length": {"value": 10, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 899, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 582, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2096, "impact_of_loft_insulation": -336, "space_heating_existing_dwelling": 13195}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080171019, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LU3 3HH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LUTON", "built_form": 2, "created_at": "2017-10-08 15:49:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10476}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Rossfold Road", "assessment_type": "RdSAP", "completion_date": "2017-10-08", "inspection_date": "2017-10-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 5, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 12.24, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "H", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.94, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 38.94, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 595, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 472, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2200, "impact_of_loft_insulation": -17, "space_heating_existing_dwelling": 9867}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200000698345, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SP11 0QA", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "ANDOVER", "built_form": 3, "created_at": "2017-10-25 16:37:23.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230001, "number_of_heaters": 1, "high_heat_retention": "true"}, {"index_number": 230002, "number_of_heaters": 1, "high_heat_retention": "true"}, {"index_number": 230004, "number_of_heaters": 1, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "2, Rectory Place Flats", "address_line_2": "Weyhill", "assessment_type": "RdSAP", "completion_date": "2017-10-25", "inspection_date": "2017-10-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 54, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.87, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.22, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 349, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": "Controls for high heat retention storage heaters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 269, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 147, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1852, "space_heating_existing_dwelling": 4178}, "energy_consumption_current": 358, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 302, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100010895302, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BL1 6HN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 4, "created_at": "2017-05-19 17:09:36.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "37, Knowsley Road", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.01, "quantity": "square metres"}, "party_wall_length": {"value": 22.14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 45.6, "quantity": "square metres"}, "party_wall_length": {"value": 20.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 772, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 591, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 249, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2217, "impact_of_loft_insulation": -529, "impact_of_cavity_insulation": -2901, "space_heating_existing_dwelling": 12458}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 133, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 45102800, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DH4 4TP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HOUGHTON LE SPRING", "built_form": 2, "created_at": "2017-06-01 00:03:32", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "22, Aster Terrace", "assessment_type": "RdSAP", "completion_date": "2017-05-31", "inspection_date": "2016-12-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 30}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 554, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 337, "currency": "GBP"}, "hot_water_cost_current": {"value": 238, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}, {"sequence": 6, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 83}, {"sequence": 7, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 103}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 128, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3158, "space_heating_existing_dwelling": 6483}, "energy_consumption_current": 351, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "1.0.x", "energy_consumption_potential": 103, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100080812145, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 31% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SG6 2SY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LETCHWORTH GARDEN CITY", "built_form": 1, "created_at": "2017-09-19 20:28:55.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8873}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Blackmore", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-09-19", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 127, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 48.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 10.79, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "I"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.19, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.57, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.61, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 31, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 660, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 138, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 627, "currency": "GBP"}, "hot_water_cost_current": {"value": 177, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3657, "space_heating_existing_dwelling": 11862}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 110, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100031028078, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NN10 0DU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "RUSHDEN", "built_form": 4, "created_at": "2017-07-20 07:51:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1311}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "38, Allen Road", "assessment_type": "RdSAP", "completion_date": "2017-07-20", "inspection_date": "2017-07-19", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 3.87, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 4.16, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 18.1, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.97, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.3, "quantity": "square metres"}, "party_wall_length": {"value": 15.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.16, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1719, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 30, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No time or thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 984, "currency": "GBP"}, "hot_water_cost_current": {"value": 258, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 240, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 30}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 30}, {"sequence": 3, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 34}, {"sequence": 4, "typical_saving": {"value": 475, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 59}], "co2_emissions_potential": 4.3, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 188, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 45, "environmental_impact_rating": 87}, {"sequence": 2, "typical_saving": {"value": 592, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 51}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3606, "impact_of_loft_insulation": -2197, "impact_of_solid_wall_insulation": -3815, "space_heating_existing_dwelling": 23969}, "energy_consumption_current": 556, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 231, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 98, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100011704935, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WN7 3QS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEIGH", "built_form": 2, "created_at": "2017-05-19 16:57:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10122}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Canaan", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.01, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.99, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 39.1, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.99, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 570, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 484, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2082, "impact_of_loft_insulation": -412, "space_heating_existing_dwelling": 7950}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 119, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040067518, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 45% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TR13 8LU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HELSTON", "built_form": 2, "created_at": "2017-04-19 21:17:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Trenethick Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-19", "inspection_date": "2017-04-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 12.1, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 9.99}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.72, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 37.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.46, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.05, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 543, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 513, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1934, "impact_of_loft_insulation": -294, "impact_of_cavity_insulation": -309, "space_heating_existing_dwelling": 9181}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r09", "energy_consumption_potential": 96, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100071058147, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"narrow_cavities": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WS4 2DN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALSALL", "built_form": 1, "created_at": "2017-09-19 19:29:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Harpur Road", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-09-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1230, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 831, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.5, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2262, "impact_of_loft_insulation": -3935, "impact_of_cavity_insulation": -5997, "space_heating_existing_dwelling": 21733}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 185, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10070493714, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE12 0HW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2017-04-20 01:47:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8440}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 11 Ash House", "address_line_2": "Burnt Ash Hill", "assessment_type": "RdSAP", "completion_date": "2017-04-20", "inspection_date": "2017-04-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.6, "quantity": "metres"}}, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.24, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 77.76, "quantity": "square metres"}, "party_wall_length": {"value": 15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 241, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 226, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2088, "space_heating_existing_dwelling": 2369}, "energy_consumption_current": 115, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 104, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 20, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10010609396, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 46% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WA7 1JS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUNCORN", "built_form": 4, "created_at": "2017-09-20 15:54:32.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9901}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "25, Waterloo Road", "assessment_type": "RdSAP", "completion_date": "2017-09-20", "inspection_date": "2017-09-19", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.96, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.4, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3, "quantity": "metres"}, "total_floor_area": {"value": 36.4, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.88, "quantity": "square metres"}, "party_wall_length": {"value": 5.51, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 14.88, "quantity": "square metres"}, "party_wall_length": {"value": 5.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.18, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.64, "quantity": "square metres"}, "party_wall_length": {"value": 2.73, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.53, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1283, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 859, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 250, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.7, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2266, "impact_of_loft_insulation": -4602, "impact_of_solid_wall_insulation": -5052, "space_heating_existing_dwelling": 22706}, "energy_consumption_current": 372, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.12r11", "energy_consumption_potential": 191, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 1775087991, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 76% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO1 2TG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PORTSMOUTH", "built_form": 3, "created_at": "2017-08-29 17:08:31.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 16455}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "90, Woodville Drive", "assessment_type": "RdSAP", "completion_date": "2017-08-29", "inspection_date": "2017-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 133, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.72, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 47.52, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.6, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 47.52, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 76, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 745, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 653, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 33, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 95, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2868, "space_heating_existing_dwelling": 11314}, "energy_consumption_current": 181, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 101, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100090923232, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR1 3RS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORWICH", "built_form": 4, "created_at": "2017-09-19 19:12:56.000000", "door_count": 3, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18090}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "127, Southwell Road", "assessment_type": "RdSAP", "completion_date": "2017-09-19", "inspection_date": "2017-09-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.75, "quantity": "square metres"}, "party_wall_length": {"value": 18.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 42.09, "quantity": "square metres"}, "party_wall_length": {"value": 18.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 440, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1830, "impact_of_loft_insulation": -477, "space_heating_existing_dwelling": 7090}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050203670, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DN15 7RJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SCUNTHORPE", "built_form": 2, "created_at": "2017-06-19 20:56:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17956}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Donnington Gardens", "assessment_type": "RdSAP", "completion_date": "2017-06-19", "inspection_date": "2017-06-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.74, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 43.14, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.62, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 929, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 596, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1841, "impact_of_solid_wall_insulation": -6329, "space_heating_existing_dwelling": 17080}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100120698668, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WR11 4AP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EVESHAM", "built_form": 4, "created_at": "2017-06-20 15:13:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "25, West Street", "assessment_type": "RdSAP", "completion_date": "2017-06-20", "inspection_date": "2017-06-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.96, "quantity": "square metres"}, "party_wall_length": {"value": 12.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 28.96, "quantity": "square metres"}, "party_wall_length": {"value": 12.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.08, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.54, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 431, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 438, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2145, "space_heating_existing_dwelling": 5473}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 95, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 44033473, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ME5 0TJ", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHATHAM", "built_form": 3, "created_at": "2017-07-19 15:28:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Meadside Walk", "assessment_type": "RdSAP", "completion_date": "2017-07-19", "inspection_date": "2017-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.85, "quantity": "square metres"}, "party_wall_length": {"value": 8.17, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 44.85, "quantity": "square metres"}, "party_wall_length": {"value": 8.17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.15, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 601, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 587, "currency": "GBP"}, "hot_water_cost_current": {"value": 270, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5223, "impact_of_loft_insulation": -4023, "space_heating_existing_dwelling": 10045}, "energy_consumption_current": 275, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 136, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060914251, "roofs": [{"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT15 6DD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DOVER", "built_form": 1, "created_at": "2017-07-20 08:34:41.000000", "door_count": 7, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15440}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "64, The Droveway", "address_line_2": "St. Margarets Bay", "assessment_type": "RdSAP", "completion_date": "2017-07-20", "inspection_date": "2017-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 144, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 69.12, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 39.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 580, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 584, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 101, "environmental_impact_rating": 97}], "co2_emissions_potential": 0.3, "energy_rating_potential": 101, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2512, "space_heating_existing_dwelling": 9846}, "energy_consumption_current": 133, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 4, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "C", "environmental_impact_potential": 97, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 25} +{"uprn": 23009449, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "M24 5UF", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2017-04-13 15:27:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.8, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 0.2, "sap_main_heating_code": 603, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Grey Street", "address_line_2": "Middleton", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.05, "quantity": "square metres"}, "party_wall_length": {"value": 8.58, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 19.05, "quantity": "square metres"}, "party_wall_length": {"value": 8.58, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.96, "quantity": "square metres"}, "party_wall_length": 8.54, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 18.96, "quantity": "square metres"}, "party_wall_length": 8.54, "heat_loss_perimeter": {"value": 4.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.51, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1645, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10.4, "energy_rating_average": 60, "energy_rating_current": 23, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 988, "currency": "GBP"}, "hot_water_cost_current": {"value": 348, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 66, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 24, "environmental_impact_rating": 18}, {"sequence": 2, "typical_saving": {"value": 134, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 28, "environmental_impact_rating": 22}, {"sequence": 3, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 26}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 26}, {"sequence": 5, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 27}, {"sequence": 6, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 28}, {"sequence": 7, "typical_saving": {"value": 419, "currency": "GBP"}, "indicative_cost": "\u00a31,600 - \u00a32,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 35}, {"sequence": 8, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 38}, {"sequence": 9, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 39}, {"sequence": 10, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 45}], "co2_emissions_potential": 5.3, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 28, "environmental_impact_rating": 22}, {"sequence": 2, "typical_saving": {"value": 466, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 49, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 508, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 52, "environmental_impact_rating": 58}], "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2530, "impact_of_loft_insulation": -4149, "impact_of_cavity_insulation": -1580, "impact_of_solid_wall_insulation": -1851, "space_heating_existing_dwelling": 17929}, "energy_consumption_current": 754, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 71, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 384, "environmental_impact_current": 17, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "F", "environmental_impact_potential": 45, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 128, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 72529049, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS9 6RW", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LEEDS", "built_form": 2, "created_at": "2017-07-12 15:55:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "12, Brecon Court", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.9, "quantity": "metres"}}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.81, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 230, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 69.78, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 607, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 497, "currency": "GBP"}, "hot_water_cost_current": {"value": 214, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 130, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 50}], "co2_emissions_potential": 4.3, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 284, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 212, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 167, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2431, "space_heating_existing_dwelling": 6857}, "energy_consumption_current": 426, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 365, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 50, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100000330461, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE33 3PN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTH SHIELDS", "built_form": 3, "created_at": "2017-07-24 11:04:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "143, East Stevenson Street", "assessment_type": "RdSAP", "completion_date": "2017-07-24", "inspection_date": "2017-07-12", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.33, "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 55.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.2, "quantity": "square metres"}, "party_wall_length": {"value": 2.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 1.2, "quantity": "square metres"}, "party_wall_length": {"value": 1.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 2.53, "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 6.33, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 682, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 434, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.2, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1918, "impact_of_loft_insulation": -325, "impact_of_cavity_insulation": -915, "impact_of_solid_wall_insulation": -3092, "space_heating_existing_dwelling": 10001}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 199, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100062096168, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT9 4AE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARGATE", "built_form": 4, "created_at": "2017-04-12 20:04:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 Lister House", "address_line_2": "Lister Road", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 34, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.97, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 270, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 237, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1465, "space_heating_existing_dwelling": 3093}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 200, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100040142141, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 85% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL25 3DL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. AUSTELL", "built_form": 1, "created_at": "2017-04-12 18:44:19.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15705}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "71, Killyvarder Way", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-12", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 133.38, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 52.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 670, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 538, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2286, "impact_of_loft_insulation": -1087, "space_heating_existing_dwelling": 11857}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 89, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 100022984445, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E17 8QT", "hot_water": {"description": {"value": "Gas multipoint", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-04-12 13:55:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 605, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Lansdowne Road", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.8, "quantity": "square metres"}, "party_wall_length": {"value": 17.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 41.8, "quantity": "square metres"}, "party_wall_length": {"value": 17.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1878, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.6, "energy_rating_average": 60, "energy_rating_current": 20, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 407, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 346, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 25}, {"sequence": 2, "typical_saving": {"value": 462, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 42}, {"sequence": 6, "typical_saving": {"value": 542, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 496, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 420, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 524, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1604, "impact_of_loft_insulation": -3142, "impact_of_solid_wall_insulation": -4198, "space_heating_existing_dwelling": 16252}, "energy_consumption_current": 598, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 30, "calculation_software_version": "1.0.x", "energy_consumption_potential": 79, "environmental_impact_current": 18, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "G", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 42131678, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CH61 3XU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIRRAL", "built_form": 1, "created_at": "2017-04-18 16:19:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Marlston Avenue", "assessment_type": "RdSAP", "completion_date": "2017-04-18", "inspection_date": "2017-04-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.324, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.468, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.379, "quantity": "metres"}, "total_floor_area": {"value": 35.468, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.31, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 506, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 460, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2059, "space_heating_existing_dwelling": 6974}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100080253979, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG18 4GE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "THATCHAM", "built_form": 4, "created_at": "2017-09-12 15:20:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "19, London Road", "assessment_type": "RdSAP", "completion_date": "2017-09-12", "inspection_date": "2017-09-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.25, "quantity": "square metres"}, "party_wall_length": {"value": 6.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 27.25, "quantity": "square metres"}, "party_wall_length": {"value": 13.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.53, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 589, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 352, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1918, "impact_of_loft_insulation": -1132, "impact_of_solid_wall_insulation": -3963, "space_heating_existing_dwelling": 10397}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 68, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 83031239, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 13% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "HD4 5RT", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "HUDDERSFIELD", "built_form": 2, "created_at": "2017-04-12 16:22:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 603, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 609, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, William Street", "address_line_2": "Crosland Moor", "assessment_type": "RdSAP", "completion_date": "2017-04-12", "inspection_date": "2017-04-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 39.85, "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.61, "quantity": "square metres"}, "party_wall_length": {"value": 7.42, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 31.61, "quantity": "square metres"}, "party_wall_length": {"value": 7.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 832, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 374, "currency": "GBP"}, "hot_water_cost_current": {"value": 307, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 351, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 8, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 178, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 343, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1975, "impact_of_solid_wall_insulation": -2470, "space_heating_existing_dwelling": 11029}, "energy_consumption_current": 463, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100051030759, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S9 1NB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 3, "created_at": "2017-10-16 13:50:39.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 602, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Merton Lane", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.95, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 120, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.71, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 36.86, "quantity": "square metres"}, "party_wall_length": {"value": 6.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.71, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 445, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2084, "space_heating_existing_dwelling": 7353}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 112, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100071533286, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY11 2YN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "OSWESTRY", "built_form": 1, "created_at": "2017-06-12 13:20:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16515}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "28, Longueville Drive", "assessment_type": "RdSAP", "completion_date": "2017-06-12", "inspection_date": "2017-06-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2017-06-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.39, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 50.39, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.69, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 6.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 917, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 704, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 145, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 305, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2738, "space_heating_existing_dwelling": 11397}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 125, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100120723783, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 54% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DY10 3NE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KIDDERMINSTER", "built_form": 1, "created_at": "2017-07-14 10:21:09", "door_count": 0, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15935}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "19, Brookside Way", "address_line_2": "Blakedown", "assessment_type": "RdSAP", "completion_date": "2017-07-14", "inspection_date": "2017-07-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 170, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-07-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 82.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 42.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 12.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1074, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 808, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 203, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 156, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3379, "impact_of_loft_insulation": -53, "impact_of_cavity_insulation": -4173, "space_heating_existing_dwelling": 19667}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 125, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100110476030, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DL5 7HJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWTON AYCLIFFE", "built_form": 1, "created_at": "2017-07-12 19:55:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "223, Angram Place", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.8, "quantity": "metres"}}, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 22.44, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 37.6, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 37.6, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 392, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 400, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1879, "space_heating_existing_dwelling": 6093}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 168, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100021340842, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM11 1LY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORNCHURCH", "built_form": 4, "created_at": "2017-07-16 11:02:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15752}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Southdown Road", "assessment_type": "RdSAP", "completion_date": "2017-07-16", "inspection_date": "2017-07-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-07-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.89, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 42.89, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1167, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 853, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 213, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.0, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2247, "impact_of_loft_insulation": -3426, "impact_of_solid_wall_insulation": -3771, "space_heating_existing_dwelling": 15743}, "energy_consumption_current": 327, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 167, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100030993175, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN14 1BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KETTERING", "built_form": 1, "created_at": "2017-06-12 13:45:04.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17503}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "44, Cardigan Road", "address_line_2": "Stanion", "assessment_type": "RdSAP", "completion_date": "2017-06-12", "inspection_date": "2017-06-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-06-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 75.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 180, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.06, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.25, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 90, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.05, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.88, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 845, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 679, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2006, "impact_of_solid_wall_insulation": -1016, "space_heating_existing_dwelling": 13042}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 134, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100120651694, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WR2 6EG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORCESTER", "built_form": 2, "created_at": "2017-10-12 09:48:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9192}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Ellison Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.23, "quantity": "square metres"}, "party_wall_length": {"value": 4.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 716, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 577, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2200, "impact_of_loft_insulation": -1888, "impact_of_cavity_insulation": -752, "space_heating_existing_dwelling": 11515}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 134, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100070690529, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CV6 7EN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 2, "created_at": "2017-06-12 10:43:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8182}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "70, Proffitt Avenue", "assessment_type": "RdSAP", "completion_date": "2017-06-12", "inspection_date": "2017-06-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.51, "quantity": "square metres"}, "party_wall_length": {"value": 8.11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 45.51, "quantity": "square metres"}, "party_wall_length": {"value": 8.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.31, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 590, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 505, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2192, "space_heating_existing_dwelling": 8701}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 106, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100030295334, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DE21 2DP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "DERBY", "built_form": 3, "created_at": "2017-05-12 13:35:58", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Bryony Close", "address_line_2": "Oakwood", "assessment_type": "RdSAP", "completion_date": "2017-05-12", "inspection_date": "2017-05-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 2, "peak_power": {"value": 2.25, "quantity": "kW"}, "orientation": 5, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 31.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 397, "currency": "GBP"}, "hot_water_cost_current": {"value": 221, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 33, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}, {"sequence": 7, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 107}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 86}, {"sequence": 3, "typical_saving": {"value": 101, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3148, "impact_of_loft_insulation": -328, "space_heating_existing_dwelling": 6442}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 85, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10000225166, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV10 9RW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NUNEATON", "built_form": 1, "created_at": "2017-07-12 20:01:42.000000", "door_count": 0, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18042}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Wells Close", "address_line_2": "Galley Common", "assessment_type": "RdSAP", "completion_date": "2017-07-12", "inspection_date": "2017-07-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.47, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 56.09, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 643, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 587, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2960, "impact_of_loft_insulation": -692, "space_heating_existing_dwelling": 11370}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 10023639791, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [6]}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PO7 7FF", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WATERLOOVILLE", "built_form": 3, "created_at": "2017-05-12 13:25:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4 Diamond Court", "address_line_2": "Coronation Road", "assessment_type": "RdSAP", "completion_date": "2017-05-12", "inspection_date": "2017-05-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7, "quantity": "metres"}}, "total_floor_area": 45, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-05-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.84, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.263, "quantity": "metres"}, "total_floor_area": {"value": 45.15, "quantity": "square metres"}, "party_wall_length": {"value": 1.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 154, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 130, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 130, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1659, "space_heating_existing_dwelling": 1684}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 231, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100040562756, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH23 2RZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHRISTCHURCH", "built_form": 1, "created_at": "2017-09-12 18:34:45.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "3, Ambleside", "assessment_type": "RdSAP", "completion_date": "2017-09-12", "inspection_date": "2017-09-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 84.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 40.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 878, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 647, "currency": "GBP"}, "hot_water_cost_current": {"value": 205, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 191, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 82}, {"sequence": 2, "typical_saving": {"value": 90, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 347, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3065, "space_heating_existing_dwelling": 10073}, "energy_consumption_current": 368, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 156, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100070459952, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B7 5PG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2017-04-13 11:39:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8227}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "162, Nechells Park Road", "assessment_type": "RdSAP", "completion_date": "2017-04-13", "inspection_date": "2017-04-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.96, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.04, "quantity": "square metres"}, "party_wall_length": {"value": 14.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.07, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 31.32, "quantity": "square metres"}, "party_wall_length": {"value": 14.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.34, "quantity": "square metres"}, "party_wall_length": {"value": 3.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 8.34, "quantity": "square metres"}, "party_wall_length": {"value": 3.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.84, "quantity": "square metres"}, "party_wall_length": {"value": 1.2, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 3.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 815, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 557, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 212, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 93, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2135, "impact_of_loft_insulation": -938, "impact_of_solid_wall_insulation": -4012, "space_heating_existing_dwelling": 12817}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 129, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100120926836, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX12 7AG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WANTAGE", "built_form": 4, "created_at": "2017-10-04 21:47:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17756}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "33, Grove Street", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 16.57, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.21, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.14, "quantity": "metres"}, "total_floor_area": {"value": 23.21, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 140, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.31, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 678, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 625, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2023, "impact_of_loft_insulation": -547, "impact_of_solid_wall_insulation": -1164, "space_heating_existing_dwelling": 12376}, "energy_consumption_current": 313, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 189, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100110035773, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TS25 5NG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARTLEPOOL", "built_form": 3, "created_at": "2017-09-04 20:18:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17044}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Wordsworth Avenue", "assessment_type": "RdSAP", "completion_date": "2017-09-04", "inspection_date": "2017-08-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.86, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 32.86, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 793, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 590, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 49, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1694, "impact_of_cavity_insulation": -2978, "space_heating_existing_dwelling": 10791}, "energy_consumption_current": 335, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 147, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100051349112, "roofs": [{"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HX7 7DL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HEBDEN BRIDGE", "built_form": 4, "created_at": "2017-05-18 06:19:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "26, Oak Street", "assessment_type": "RdSAP", "completion_date": "2017-05-18", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 390, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 26.63, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.91, "quantity": "square metres"}, "party_wall_length": {"value": 13.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 26.91, "quantity": "square metres"}, "party_wall_length": {"value": 13.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1325, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.2, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 584, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 458, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 2.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 130, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "impact_of_loft_insulation": -28, "impact_of_solid_wall_insulation": -2277, "space_heating_existing_dwelling": 19323}, "energy_consumption_current": 496, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 147, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 89, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 47054027, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE29 8DH", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NORTH SHIELDS", "built_form": 2, "created_at": "2017-08-20 09:46:18.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "23, Langholm Avenue", "assessment_type": "RdSAP", "completion_date": "2017-08-20", "inspection_date": "2017-08-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.2, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 51.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 438, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 285, "currency": "GBP"}, "hot_water_cost_current": {"value": 282, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 184, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 210, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 222, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2072, "impact_of_solid_wall_insulation": -983, "space_heating_existing_dwelling": 4919}, "energy_consumption_current": 436, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 323, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100080006363, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK40 3UA", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BEDFORD", "built_form": 2, "created_at": "2017-10-19 13:49:58.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1852}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "228, Castle Road", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.51, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 37.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 705, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 283, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 188, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 109, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4332, "impact_of_loft_insulation": -203, "impact_of_cavity_insulation": -3181, "space_heating_existing_dwelling": 9884}, "energy_consumption_current": 371, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 91, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 3040018909, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG12 4BE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2017-10-17 16:14:05", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "34, Greenacre", "address_line_2": "Edwalton", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 50}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 43.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 466, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 86, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 429, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2165, "impact_of_loft_insulation": -278, "space_heating_existing_dwelling": 7668}, "energy_consumption_current": 96, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 71, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "B", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 17, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 200002836918, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CW10 9ES", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MIDDLEWICH", "built_form": 1, "created_at": "2017-10-18 08:51:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "15, Shropshire Close", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 667, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 453, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 156, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2571, "impact_of_loft_insulation": -429, "space_heating_existing_dwelling": 8662}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 118, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100031376907, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true"}, "lighting": {"description": {"value": "Low energy lighting in 42% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG4 3LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2017-05-17 16:12:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15032}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Priory Road", "address_line_2": "Gedling", "assessment_type": "RdSAP", "completion_date": "2017-05-17", "inspection_date": "2017-05-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 148, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2017-05-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.83, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 42.83, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 19.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 31.27, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 15.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 915, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 653, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2990, "impact_of_loft_insulation": -1050, "impact_of_cavity_insulation": -3643, "space_heating_existing_dwelling": 16496}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 100, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100090713084, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SS0 0PD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WESTCLIFF-ON-SEA", "built_form": 2, "created_at": "2017-10-17 17:37:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16454}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "40, Richmond Drive", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 2236, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 6, "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 2147, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 5.69}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.25, "quantity": "square metres"}, "party_wall_length": {"value": 8.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 41.99, "quantity": "square metres"}, "party_wall_length": {"value": 7.37, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.76, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 9650, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 53, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 491, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 8996, "currency": "GBP"}, "hot_water_cost_current": {"value": 193, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 654, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 65}], "co2_emissions_potential": 50, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 491, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 193, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4059, "impact_of_loft_insulation": -207, "space_heating_existing_dwelling": 208602}, "energy_consumption_current": 134, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 125, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 48081745, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR4 1SA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "MITCHAM", "built_form": 3, "created_at": "2017-07-18 08:39:36.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat B Block 4 Maytree Court", "address_line_2": "50, Grove Road", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 4.22}, "total_floor_area": 46, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.9592, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.86, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 277, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": "No time or thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 224, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2010, "space_heating_existing_dwelling": 3244}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 155, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080101506, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LU5 5AL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DUNSTABLE", "built_form": 4, "created_at": "2017-05-18 10:01:54.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15464}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Northfields", "assessment_type": "RdSAP", "completion_date": "2017-05-18", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.57, "quantity": "square metres"}, "party_wall_length": {"value": 12.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 32.57, "quantity": "square metres"}, "party_wall_length": {"value": 12.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 458, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 357, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3061, "impact_of_loft_insulation": -348, "impact_of_cavity_insulation": -2006, "space_heating_existing_dwelling": 7301}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100051256659, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BD20 9LH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KEIGHLEY", "built_form": 4, "created_at": "2017-08-17 14:23:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Clifford Street", "address_line_2": "Silsden", "assessment_type": "RdSAP", "completion_date": "2017-08-17", "inspection_date": "2017-08-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.59, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 19.59, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 19.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 844, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 507, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2094, "impact_of_loft_insulation": -256, "impact_of_solid_wall_insulation": -3755, "space_heating_existing_dwelling": 10384}, "energy_consumption_current": 328, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 113, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100100625807, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA8 3HL", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SWANSEA", "built_form": 1, "created_at": "2017-05-18 22:25:01.000000", "door_count": 0, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "33, Ashwood Drive", "address_line_2": "Gellinudd, Pontardawe", "assessment_type": "RdSAP", "completion_date": "2017-05-18", "inspection_date": "2017-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2017-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 25.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 782, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 423, "currency": "GBP"}, "hot_water_cost_current": {"value": 328, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 8, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 93, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4374, "impact_of_cavity_insulation": -2890, "space_heating_existing_dwelling": 9694}, "energy_consumption_current": 381, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 86, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10092967314, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Sandstone or limestone, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA19 9DY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LLANGADOG", "built_form": 1, "created_at": "2017-10-18 13:07:42.000000", "door_count": 4, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 10500}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 160}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Dau Cae", "assessment_type": "RdSAP", "completion_date": "2017-10-18", "inspection_date": "2017-10-17", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 125, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.03, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 24.643, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.141, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.114, "quantity": "metres"}, "total_floor_area": {"value": 24.643, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 12.211, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.03, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.903, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.983, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.114, "quantity": "metres"}, "total_floor_area": {"value": 15.903, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.983, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.03, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.687, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.328, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.114, "quantity": "metres"}, "total_floor_area": {"value": 18.687, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.328, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.03, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.666, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.834, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 400, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 376, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 101, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.8, "energy_rating_potential": 101, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2695, "space_heating_existing_dwelling": 9157}, "energy_consumption_current": 128, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": -20, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 202051931, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW2 4PH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-24 15:32:43.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10324}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "44, Riffel Road", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-24", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 206, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 47.08, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.05, "quantity": "square metres"}, "party_wall_length": {"value": 14.54, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 39.05, "quantity": "square metres"}, "party_wall_length": {"value": 14.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.78, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.42, "quantity": "square metres"}, "party_wall_length": {"value": 8.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 29.42, "quantity": "square metres"}, "party_wall_length": {"value": 8.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.92, "quantity": "square metres"}, "party_wall_length": {"value": 3.17, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1512, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 912, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 406, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 4.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 139, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2910, "impact_of_loft_insulation": -2270, "impact_of_solid_wall_insulation": -2688, "space_heating_existing_dwelling": 30677}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 120, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 40, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 28} +{"uprn": 10012968568, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR13 0ET", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HELSTON", "built_form": 1, "created_at": "2017-10-03 10:34:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8895}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Higher Trenear Farm", "address_line_2": "Trenear", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-10-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 189, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 650, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 82, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "250mm"}, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 107.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 48.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 859, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 551, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 183, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 556, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.1, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 146, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3544, "impact_of_solid_wall_insulation": -3551, "space_heating_existing_dwelling": 15989}, "energy_consumption_current": 152, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 14, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 21} +{"uprn": 41089088, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L30 2RL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOOTLE", "built_form": 2, "created_at": "2017-10-16 21:24:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17761}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, St. Augustines Way", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 63, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 702, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 483, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 177, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2279, "impact_of_loft_insulation": -321, "impact_of_cavity_insulation": -3940, "space_heating_existing_dwelling": 12904}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 86, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100040097286, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [9]}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PL28 8DL", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PADSTOW", "built_form": 1, "created_at": "2017-09-14 16:29:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 0.7, "sap_main_heating_code": 506, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.3, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 694, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Warm air, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "28, Egerton Road", "assessment_type": "RdSAP", "completion_date": "2017-09-14", "inspection_date": "2017-09-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-09-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 33.18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 511, "currency": "GBP"}, "hot_water_cost_current": {"value": 211, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "2,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 145, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 188, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 216, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3347, "impact_of_loft_insulation": -596, "space_heating_existing_dwelling": 7517}, "energy_consumption_current": 381, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 147, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 207124152, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EN2 7LN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ENFIELD", "built_form": 2, "created_at": "2017-07-17 19:26:57.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10167}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "46, Curthwaite Gardens", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-14", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.04, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 39.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.94, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 5.94, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 6.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.68, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 592, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 566, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2943, "impact_of_loft_insulation": -532, "space_heating_existing_dwelling": 10070}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 22020064, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN3 8ET", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOVE", "built_form": 2, "created_at": "2017-07-18 12:15:38.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Chichester Close", "assessment_type": "RdSAP", "completion_date": "2017-07-18", "inspection_date": "2017-07-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.44, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.44, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 642, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 437, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 167, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2099, "impact_of_loft_insulation": -209, "impact_of_cavity_insulation": -3461, "space_heating_existing_dwelling": 10797}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 90, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100050023032, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO15 2DS", "hot_water": {"description": {"value": "Gas multipoint", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BRIDLINGTON", "built_form": 2, "created_at": "2017-05-02 22:55:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "50, Marshall Avenue", "assessment_type": "RdSAP", "completion_date": "2017-05-02", "inspection_date": "2017-04-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.3, "quantity": "metres"}}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-05-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.656, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 36.1, "quantity": "square metres"}, "party_wall_length": {"value": 10.94, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 967, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 227, "currency": "GBP"}, "hot_water_cost_current": {"value": 70, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 417, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 165, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 151, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 82}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1081, "impact_of_cavity_insulation": -1561, "impact_of_solid_wall_insulation": -315, "space_heating_existing_dwelling": 10015}, "energy_consumption_current": 923, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 182, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 156, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 46020963, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E12 5QG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-07-16 18:39:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15701}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "112, Dersingham Avenue", "assessment_type": "RdSAP", "completion_date": "2017-07-16", "inspection_date": "2017-07-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-07-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.39, "quantity": "square metres"}, "party_wall_length": {"value": 13.16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 31.9, "quantity": "square metres"}, "party_wall_length": {"value": 13.77, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.79, "quantity": "square metres"}, "party_wall_length": {"value": 5.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.34, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 15.78, "quantity": "square metres"}, "party_wall_length": {"value": 5.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 659, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 467, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 92, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 192, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "impact_of_loft_insulation": -1174, "impact_of_solid_wall_insulation": -4414, "space_heating_existing_dwelling": 11933}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "9.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100080714310, "roofs": [{"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HP23 6AU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TRING", "built_form": 2, "created_at": "2017-08-15 00:28:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10337}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Albert Street", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 5, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 11.78, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "H"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 25.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.1, "quantity": "square metres"}, "party_wall_length": {"value": 4.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 8.1, "quantity": "square metres"}, "party_wall_length": {"value": 4.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 694, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 559, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2150, "impact_of_loft_insulation": -1166, "impact_of_solid_wall_insulation": -3120, "space_heating_existing_dwelling": 12704}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 132, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 200003003161, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S5 8RU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 2, "created_at": "2017-09-15 18:14:41.000000", "door_count": 1, "glazed_area": 5, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 15019}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 1.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 0.48, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 2}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 0.28, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 2}, {"orientation": 8, "window_area": {"value": 1.56, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"orientation": 4, "window_area": {"value": 0.76, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 2.85, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 1.33, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 1.33, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 0.69, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"orientation": 8, "window_area": {"value": 1.33, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"orientation": 6, "window_area": {"value": 0.55, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"orientation": 4, "window_area": {"value": 0.55, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 0.55, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 1.33, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Moonshine Way", "assessment_type": "RdSAP", "completion_date": "2017-09-15", "inspection_date": "2017-09-14", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2017-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.62, "quantity": "square metres"}, "party_wall_length": {"value": 7.43, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 32.62, "quantity": "square metres"}, "party_wall_length": {"value": 7.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.12, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 11.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 14.12, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 550, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 564, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2898, "impact_of_loft_insulation": -324, "space_heating_existing_dwelling": 7637}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 118, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010902011, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BL4 9RE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 2, "created_at": "2017-08-15 11:57:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 607, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "52, MacDonald Avenue", "address_line_2": "Farnworth", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.79, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 41.79, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.69, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 819, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 784, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 250, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.3, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2140, "impact_of_loft_insulation": -3742, "space_heating_existing_dwelling": 13074}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 219, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090362608, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SS7 2DN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BENFLEET", "built_form": 1, "created_at": "2017-07-17 11:12:14.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8440}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "42, Meadow Road", "assessment_type": "RdSAP", "completion_date": "2017-07-17", "inspection_date": "2017-07-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 180, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 35.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 763, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 633, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.1, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 53}}], "hot_water_cost_potential": {"value": 42, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1771, "space_heating_existing_dwelling": 11562}, "energy_consumption_current": 436, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 213, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200001540196, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RM15 5BA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTH OCKENDON", "built_form": 4, "created_at": "2017-10-14 16:46:14.000000", "door_count": 0, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "56, Arisdale Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-14", "inspection_date": "2017-10-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2017-10-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.33, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 36.69, "quantity": "square metres"}, "party_wall_length": {"value": 12.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 814, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "No time or thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 671, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2212, "impact_of_loft_insulation": -3100, "space_heating_existing_dwelling": 14380}, "energy_consumption_current": 346, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 194, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10011958029, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR20 3SU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DEREHAM", "built_form": 1, "created_at": "2017-08-14 20:47:10.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1848}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Teasel Close", "assessment_type": "RdSAP", "completion_date": "2017-08-14", "inspection_date": "2017-08-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "registration_date": "2017-08-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.01, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 59.01, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 769, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 642, "currency": "GBP"}, "hot_water_cost_current": {"value": 158, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 207, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2815, "space_heating_existing_dwelling": 10346}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 110, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 36000355, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA14 3LR", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BARROW-IN-FURNESS", "built_form": 2, "created_at": "2017-06-15 07:19:22.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Maryport Avenue", "address_line_2": "Walney", "assessment_type": "RdSAP", "completion_date": "2017-06-15", "inspection_date": "2017-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.44, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 35.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.87, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 893, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 496, "currency": "GBP"}, "hot_water_cost_current": {"value": 384, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 244, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 250, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 207, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 397, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5096, "impact_of_cavity_insulation": -3523, "space_heating_existing_dwelling": 11145}, "energy_consumption_current": 489, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 86, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100030337335, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE21 6PW", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "DERBY", "built_form": 2, "created_at": "2017-06-14 20:14:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 633, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Meadow Lane", "address_line_2": "Chaddesden", "assessment_type": "RdSAP", "completion_date": "2017-06-14", "inspection_date": "2017-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-06-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.1, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1209, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.3, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 554, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 578, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2030, "impact_of_solid_wall_insulation": -7705, "space_heating_existing_dwelling": 16020}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 135, "environmental_impact_current": 32, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100071518103, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV6 6FN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 1, "created_at": "2017-06-21 11:55:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "37a, Lythalls Lane", "assessment_type": "RdSAP", "completion_date": "2017-06-21", "inspection_date": "2017-06-14", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.96, "quantity": "metres"}}, "total_floor_area": 29, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.96, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.54, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 509, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 23, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 259, "currency": "GBP"}, "hot_water_cost_current": {"value": 69, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.3, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 23, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1408, "impact_of_solid_wall_insulation": -3691, "space_heating_existing_dwelling": 8411}, "energy_consumption_current": 499, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "9.0.0", "energy_consumption_potential": 248, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 88, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100121151895, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN5 5FL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 4, "created_at": "2017-10-21 20:01:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1821}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "15, Rannoch Close", "address_line_2": "Sparcells", "assessment_type": "RdSAP", "completion_date": "2017-10-21", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 56, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.43, "quantity": "square metres"}, "party_wall_length": {"value": 13.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 32.43, "quantity": "square metres"}, "party_wall_length": {"value": 13.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 410, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 331, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 45, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1792, "impact_of_loft_insulation": -301, "space_heating_existing_dwelling": 5245}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["W2", "X"], "calculation_software_version": "2.13r13", "energy_consumption_potential": 60, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 37000794, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 54% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO13 8HH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEE-ON-THE-SOLENT", "built_form": 4, "created_at": "2017-10-12 14:51:58.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8441}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Sea Crest Road", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.302, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.189, "quantity": "square metres"}, "party_wall_length": {"value": 14.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.361, "quantity": "metres"}, "total_floor_area": {"value": 36.189, "quantity": "square metres"}, "party_wall_length": {"value": 14.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.188, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.933, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.145, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.302, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.986, "quantity": "square metres"}, "party_wall_length": {"value": 5.155, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 589, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 464, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 112, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2181, "impact_of_loft_insulation": -789, "impact_of_cavity_insulation": -351, "space_heating_existing_dwelling": 7142}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 78, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100010059014, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CW11 4PF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SANDBACH", "built_form": 1, "created_at": "2017-10-04 13:44:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10126}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "16, Third Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.52, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 741, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2020, "impact_of_loft_insulation": -691, "impact_of_cavity_insulation": -2949, "space_heating_existing_dwelling": 11919}, "energy_consumption_current": 330, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 123, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10070396365, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M4 2BJ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 6, "created_at": "2017-10-19 15:47:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2605, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 102", "address_line_2": "33, Withy Grove", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.22, "quantity": "metres"}}, "total_floor_area": 28, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.6958, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 27.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 86, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 25, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 49, "currency": "GBP"}, "hot_water_cost_current": {"value": 218, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 138, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 132, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 88}], "hot_water_cost_potential": {"value": 114, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1387, "space_heating_existing_dwelling": 546}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 251, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 90012817, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "DY5 1UQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIERLEY HILL", "built_form": 2, "created_at": "2017-10-09 19:24:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Sheriff Drive", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 7.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 458, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 395, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "impact_of_loft_insulation": -219, "space_heating_existing_dwelling": 6741}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 90, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 148042841, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EN8 7FB", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WALTHAM CROSS", "built_form": 4, "created_at": "2017-10-24 16:07:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2605, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "56 Gwendoline Court", "address_line_2": "Bryanstone Road", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.9, "quantity": "metres"}}, "total_floor_area": 43, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.801, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 42.53, "quantity": "square metres"}, "party_wall_length": {"value": 16.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 103, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 66, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 97, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 88}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1630, "space_heating_existing_dwelling": 697}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 187, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "B", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100062573024, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN34 3RS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "HASTINGS", "built_form": 4, "created_at": "2017-10-14 12:54:13.000000", "door_count": 1, "glazed_area": 4, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 4, "window_area": {"value": 1.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 3, "window_area": {"value": 1.13, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 1.13, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 1.61, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 7, "window_area": {"value": 0.85, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 0.85, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 2.24, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 4, "window_area": {"value": 2.47, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "false", "orientation": 8, "window_area": {"value": 2.39, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}], "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Upper Floor Maisonette", "address_line_2": "75 Milward Road", "assessment_type": "RdSAP", "completion_date": "2017-10-14", "inspection_date": "2017-10-12", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 0.82, "quantity": "metres"}}, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "sap_room_in_roof": {"floor_area": 30.77, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.132, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 100, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 45.06, "quantity": "square metres"}, "party_wall_length": {"value": 16.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2, "quantity": "square metres"}, "party_wall_length": 5.7, "floor_construction": 2, "heat_loss_perimeter": {"value": 0.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 934, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 436, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 58, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 396, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.5, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2343, "impact_of_loft_insulation": -1165, "impact_of_solid_wall_insulation": -1139, "space_heating_existing_dwelling": 14145}, "energy_consumption_current": 359, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 175, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100090769532, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR19 1LU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DEREHAM", "built_form": 1, "created_at": "2017-10-27 15:06:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1966}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "37, Boyd Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-27", "inspection_date": "2017-10-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.46, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 551, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 424, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2534, "space_heating_existing_dwelling": 6972}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100110597774, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE24 1JL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLYTH", "built_form": 4, "created_at": "2017-10-05 13:33:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "68, Salisbury Street", "assessment_type": "RdSAP", "completion_date": "2017-10-05", "inspection_date": "2017-10-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.9, "quantity": "square metres"}, "party_wall_length": {"value": 16.92, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 54.9, "quantity": "square metres"}, "party_wall_length": {"value": 16.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 677, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 525, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 2.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2269, "impact_of_solid_wall_insulation": -3114, "space_heating_existing_dwelling": 11525}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 99, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100090320551, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO9 1EE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HALSTEAD", "built_form": 2, "created_at": "2017-10-17 09:09:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "2, Upper Trinity Road", "assessment_type": "RdSAP", "completion_date": "2017-10-17", "inspection_date": "2017-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.18, "quantity": "square metres"}, "party_wall_length": {"value": 8.11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.34, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 343, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 306, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2470, "impact_of_loft_insulation": -306, "space_heating_existing_dwelling": 5298}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 70, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10001310626, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO19 6RR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2017-10-23 17:26:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1758}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "32, Mosaic Close", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.19, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.85, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.19, "quantity": "metres"}, "total_floor_area": {"value": 45.17, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 438, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 355, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2127, "space_heating_existing_dwelling": 6293}, "energy_consumption_current": 181, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 60, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100090873789, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NR28 0SY", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NORTH WALSHAM", "built_form": 2, "created_at": "2017-10-19 17:06:21.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1386}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Juler Close", "assessment_type": "RdSAP", "completion_date": "2017-10-19", "inspection_date": "2017-10-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 32.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 592, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 427, "currency": "GBP"}, "hot_water_cost_current": {"value": 233, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 8, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 133, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 138, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 185, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3162, "impact_of_loft_insulation": -333, "space_heating_existing_dwelling": 6279}, "energy_consumption_current": 338, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 90, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010808267, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "FY3 7NY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKPOOL", "built_form": 3, "created_at": "2017-10-12 20:52:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 10068}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Hockley Place", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.66, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 43.66, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 794, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 602, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2168, "impact_of_loft_insulation": -3625, "impact_of_cavity_insulation": -3818, "space_heating_existing_dwelling": 15249}, "energy_consumption_current": 290, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 149, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100050095283, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HU10 6PJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 1, "created_at": "2017-10-03 07:47:22.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 607, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "65, Prunus Avenue", "address_line_2": "Willerby", "assessment_type": "RdSAP", "completion_date": "2017-10-03", "inspection_date": "2017-10-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2017-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.65, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.45, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 593, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 527, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2386, "space_heating_existing_dwelling": 9534}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 126, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 45143599, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SR2 8JP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 4, "created_at": "2017-10-06 17:08:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Apartment 2 Stanfield House", "address_line_2": "Gray Road", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 8.76}, "total_floor_area": 55, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.148, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 360, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.76, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 236, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1779, "space_heating_existing_dwelling": 2649}, "energy_consumption_current": 140, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 140, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10093494715, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE1 2TZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PETERBOROUGH", "built_form": 5, "created_at": "2017-10-10 12:39:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 8", "address_line_2": "117, Park Road", "assessment_type": "RdSAP", "completion_date": "2017-10-10", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.3, "quantity": "metres"}}, "total_floor_area": 37, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.12, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.9, "quantity": "square metres"}, "party_wall_length": {"value": 3.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 473, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 221, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 181, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 229, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 208, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 120, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1668, "space_heating_existing_dwelling": 3371}, "energy_consumption_current": 434, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 371, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100021969463, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 10% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SE26 4TH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-26 14:38:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "15, Holmshaw Close", "assessment_type": "RdSAP", "completion_date": "2017-10-26", "inspection_date": "2017-10-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.15, "quantity": "square metres"}, "party_wall_length": {"value": 16.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 37.99, "quantity": "square metres"}, "party_wall_length": {"value": 14.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 473, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 303, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 7, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2068, "impact_of_loft_insulation": -557, "impact_of_cavity_insulation": -1552, "space_heating_existing_dwelling": 7860}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.13r13", "energy_consumption_potential": 44, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100021326969, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM12 6UA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORNCHURCH", "built_form": 2, "created_at": "2017-10-13 20:35:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5928}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Crawford Compton Close", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.96, "quantity": "square metres"}, "party_wall_length": {"value": 8.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 30.96, "quantity": "square metres"}, "party_wall_length": {"value": 8.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 369, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 308, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2420, "impact_of_loft_insulation": -321, "space_heating_existing_dwelling": 4773}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 55, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010284905, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 21% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "WA4 3BE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WARRINGTON", "built_form": 2, "created_at": "2017-10-24 22:47:14.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16810}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Greenfields Avenue", "address_line_2": "Appleton", "assessment_type": "RdSAP", "completion_date": "2017-10-24", "inspection_date": "2017-10-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.33, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.45, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.35, "quantity": "square metres"}, "party_wall_length": {"value": 2.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 21, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 766, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 746, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "co2_emissions_potential": 3.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "impact_of_loft_insulation": -3811, "space_heating_existing_dwelling": 12638}, "energy_consumption_current": 261, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r13", "energy_consumption_potential": 180, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100040961023, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in 74% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TA24 8DU", "hot_water": {"description": {"value": "From main system, plus solar", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "MINEHEAD", "built_form": 1, "created_at": "2017-10-23 10:57:38.000000", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5933}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "White Lodge", "address_line_2": "Periton Road", "assessment_type": "RdSAP", "completion_date": "2017-10-23", "inspection_date": "2017-10-20", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 255, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2017-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 3, "peak_power": {"value": 3.185, "quantity": "kW"}, "orientation": 5, "overshading": 2, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10, 11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 107.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 43.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 105.38, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 39.62, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "50mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 16.85, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 1, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 3.04, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 74, "solar_water_heating": "Y", "habitable_room_count": 7, "heating_cost_current": {"value": 1482, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1325, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 178, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}], "co2_emissions_potential": 6.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 139, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 316, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3031, "impact_of_loft_insulation": -282, "space_heating_existing_dwelling": 24724}, "energy_consumption_current": 149, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 129, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 19, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100060334164, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PO14 4JB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FAREHAM", "built_form": 2, "created_at": "2017-10-16 03:16:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "88, Bellfield", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.07, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 44.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.69, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 546, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 504, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2061, "space_heating_existing_dwelling": 7595}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 90, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 21077072, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HU4 6HD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 2, "created_at": "2017-10-04 21:18:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "21, Rawcliffe Grove", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 652, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 623, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2050, "space_heating_existing_dwelling": 11767}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 166, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100121157586, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN3 2DW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 1, "created_at": "2017-10-06 17:45:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16841}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "23, Studland Close", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 348, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 304, "currency": "GBP"}, "hot_water_cost_current": {"value": 65, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.3, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 40, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1410, "space_heating_existing_dwelling": 4114}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 40, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100070617674, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CV6 2HJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 4, "created_at": "2017-10-16 10:44:47.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8108}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "308, Beake Avenue", "assessment_type": "RdSAP", "completion_date": "2017-10-16", "inspection_date": "2017-10-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.64, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 40.19, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.99, "quantity": "square metres"}, "party_wall_length": {"value": 10, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 696, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 641, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2257, "impact_of_loft_insulation": -4013, "space_heating_existing_dwelling": 11400}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r12", "energy_consumption_potential": 134, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200002698749, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE13 1PT", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "MELTON MOWBRAY", "built_form": 1, "created_at": "2017-10-09 10:51:30.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 47 Beck Mill Court", "address_line_2": "Beck Mill Street", "assessment_type": "RdSAP", "completion_date": "2017-10-09", "inspection_date": "2017-10-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2017-10-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 466, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 298, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 47}], "co2_emissions_potential": 3.8, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 225, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 298, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4099, "space_heating_existing_dwelling": 5238}, "energy_consumption_current": 621, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 477, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 47, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 23002632, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "M24 4NA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2017-05-19 17:24:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Gatesgarth Road", "address_line_2": "Middleton", "assessment_type": "RdSAP", "completion_date": "2017-05-19", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2017-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.052, "quantity": "square metres"}, "party_wall_length": {"value": 5.65, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.412, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 42.923, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.194, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 455, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 425, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1864, "space_heating_existing_dwelling": 7291}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010061672, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 7% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "ST7 2YJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2017-08-15 17:30:14.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Cranford Mews", "address_line_2": "Alsager", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.98, "quantity": "square metres"}, "party_wall_length": {"value": 8.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 30.9, "quantity": "square metres"}, "party_wall_length": {"value": 8.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 7, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 402, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 332, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 65, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2237, "space_heating_existing_dwelling": 4902}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 70, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 63123861, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WF1 3RU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "WAKEFIELD", "built_form": 4, "created_at": "2017-08-15 17:58:15.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Westfield View", "assessment_type": "RdSAP", "completion_date": "2017-08-15", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 114, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "sap_room_in_roof": {"floor_area": {"value": 27.17, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.04, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.19, "quantity": "square metres"}, "party_wall_length": {"value": 18.219999, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.86, "quantity": "metres"}, "total_floor_area": {"value": 44.08, "quantity": "square metres"}, "party_wall_length": {"value": 18.219999, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1094, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 140, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 738, "currency": "GBP"}, "hot_water_cost_current": {"value": 76, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1683, "impact_of_loft_insulation": -1353, "impact_of_cavity_insulation": -1512, "space_heating_existing_dwelling": 20605}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 152, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100040624667, "roofs": [{"description": "Pitched, 350 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "DT6 4PW", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BRIDPORT", "built_form": 1, "created_at": "2017-08-16 08:15:40", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1994}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Boundary Cottage", "address_line_2": "Icen Lane", "address_line_3": "Shipton Gorge", "assessment_type": "RdSAP", "completion_date": "2017-08-16", "inspection_date": "2017-08-15", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 174, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-08-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 1, "percent_roof_area": 45}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 58.04, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.81, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 1, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.19, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.91, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1615, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 162, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 849, "currency": "GBP"}, "hot_water_cost_current": {"value": 208, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 533, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a395", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 79}, {"sequence": 6, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 84}, {"sequence": 7, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 50, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 108}, {"sequence": 3, "typical_saving": {"value": 238, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3494, "impact_of_loft_insulation": -2680, "impact_of_cavity_insulation": -742, "impact_of_solid_wall_insulation": -9684, "space_heating_existing_dwelling": 25725}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.12r11", "energy_consumption_potential": 38, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 23, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100120496204, "roofs": [{"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "GL4 0JE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GLOUCESTER", "built_form": 2, "created_at": "2017-10-20 14:41:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10265}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "8, Winchester Drive", "address_line_2": "Tuffley", "assessment_type": "RdSAP", "completion_date": "2017-10-20", "inspection_date": "2017-10-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2017-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 27.53, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "D"}, "roof_construction": 8, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.73, "quantity": "square metres"}, "party_wall_length": {"value": 7.52, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.66, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1163, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 512, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 220, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 362, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2229, "space_heating_existing_dwelling": 18522}, "energy_consumption_current": 345, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 90, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 33026620, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TW15 1TW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHFORD", "built_form": 3, "created_at": "2017-10-04 18:08:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15751}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "79, Alexandra Road", "assessment_type": "RdSAP", "completion_date": "2017-10-04", "inspection_date": "2017-10-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2017-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.98, "quantity": "square metres"}, "party_wall_length": {"value": 8.28, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 29.81, "quantity": "square metres"}, "party_wall_length": {"value": 8.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 782, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 395, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 197, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2080, "impact_of_loft_insulation": -2381, "impact_of_solid_wall_insulation": -3960, "space_heating_existing_dwelling": 13244}, "energy_consumption_current": 323, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 80, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 202130079, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 42% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NW9 9DG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2017-10-12 23:01:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 107, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "78, Berkeley Road", "assessment_type": "RdSAP", "completion_date": "2017-10-12", "inspection_date": "2017-10-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 127, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 23.1, "quantity": "square metres"}, "insulation": 3, "roof_room_connected": "N", "construction_age_band": "C", "roof_insulation_thickness": "100mm"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.14, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 42.14, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "NI"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 853, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 520, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 93, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 163, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2299, "impact_of_loft_insulation": -203, "impact_of_solid_wall_insulation": -2256, "space_heating_existing_dwelling": 12609}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 84, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100030073011, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S80 4QT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORKSOP", "built_form": 2, "created_at": "2017-10-06 09:52:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "3, Longcroft View", "address_line_2": "Whitwell", "assessment_type": "RdSAP", "completion_date": "2017-10-06", "inspection_date": "2017-10-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2017-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.66, "quantity": "square metres"}, "party_wall_length": {"value": 7.47, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.71, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 414, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 363, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2072, "space_heating_existing_dwelling": 6571}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.13r09", "energy_consumption_potential": 90, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200002598670, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HR2 7UB", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "HEREFORD", "built_form": 4, "created_at": "2017-10-15 17:30:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 613, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Yarlington Mill", "address_line_2": "Belmont", "assessment_type": "RdSAP", "completion_date": "2017-10-15", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2017-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.39, "quantity": "square metres"}, "party_wall_length": {"value": 15.86, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 28.39, "quantity": "square metres"}, "party_wall_length": {"value": 15.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.16, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 371, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 297, "currency": "GBP"}, "hot_water_cost_current": {"value": 279, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 243, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 252, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 210, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 178, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1793, "impact_of_loft_insulation": -142, "space_heating_existing_dwelling": 4880}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 52, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100031515450, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 85% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG11 9FX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2017-10-13 16:54:28.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Avebury Close", "assessment_type": "RdSAP", "completion_date": "2017-10-13", "inspection_date": "2017-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2017-10-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.7, "quantity": "square metres"}, "party_wall_length": {"value": 14.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 39.3, "quantity": "square metres"}, "party_wall_length": {"value": 14.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 490, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2100, "impact_of_loft_insulation": -943, "space_heating_existing_dwelling": 6809}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v92.0.1.1", "energy_consumption_potential": 110, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10003980266, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N8 7RZ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 5, "created_at": "2017-08-18 07:01:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2605, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 12 Fyfe House", "address_line_2": "Chadwell Lane", "assessment_type": "RdSAP", "completion_date": "2017-08-18", "inspection_date": "2017-08-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10, "quantity": "metres"}}, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2017-08-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.5, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 59.28, "quantity": "square metres"}, "party_wall_length": {"value": 5.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 188, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 107, "currency": "GBP"}, "hot_water_cost_current": {"value": 301, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 237, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 278, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 253, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 141, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1917, "space_heating_existing_dwelling": 1200}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["W2"], "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 178, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100081024478, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG30 4JN", "hot_water": {"description": "From main system, plus solar", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "READING", "built_form": 1, "created_at": "2017-05-16 10:38:33", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10312}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and underfloor heating, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Tattra", "address_line_2": "New Lane Hill", "address_line_3": "Tilehurst", "assessment_type": "RdSAP", "completion_date": "2017-05-16", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 250, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "false", "registration_date": "2017-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 38.84, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "J", "roof_insulation_thickness": "100mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 112.41, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 48.87, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 99.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 41.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "Y", "habitable_room_count": 8, "heating_cost_current": {"value": 934, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 934, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 78}], "co2_emissions_potential": 4.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 109, "currency": "GBP"}, "schema_version_original": "LIG-17.1", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2718, "space_heating_existing_dwelling": 16966}, "energy_consumption_current": 111, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.11r11", "energy_consumption_potential": 89, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 36, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 20, "low_energy_fixed_lighting_outlets_count": 36} +{"uprn": 100071221037, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 95% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY1 4TP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHREWSBURY", "built_form": 1, "created_at": "2017-07-15 13:23:48.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8873}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Old Farm House", "address_line_2": "Goldcrest Drive", "assessment_type": "RdSAP", "completion_date": "2017-07-15", "inspection_date": "2017-07-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 222, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 8, "pvc_window_frames": "false", "registration_date": "2017-07-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 265, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 121.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 49.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.21, "quantity": "metres"}, "total_floor_area": {"value": 100.86, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 49.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 95, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1894, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.6, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1051, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 651, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 4.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 107, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "hot_water_cost_potential": {"value": 140, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2919, "impact_of_solid_wall_insulation": -11467, "space_heating_existing_dwelling": 31307}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 10033043472, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PR26 7SH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEYLAND", "built_form": 1, "created_at": "2017-05-15 13:20:59.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16511}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.92, "schema_type": "RdSAP-Schema-17.1", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "143, Slater Lane", "assessment_type": "RdSAP", "completion_date": "2017-05-15", "inspection_date": "2017-05-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 154, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2017-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 77.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 76.3, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 36.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1201, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 867, "currency": "GBP"}, "hot_water_cost_current": {"value": 211, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 225, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-17.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 136, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 129, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 393, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2994, "impact_of_loft_insulation": -482, "space_heating_existing_dwelling": 14766}, "energy_consumption_current": 250, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "1.0.x", "energy_consumption_potential": 129, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 10} diff --git a/backend/epc_api/json_samples/RdSAP-Schema-18.0/corpus.jsonl b/backend/epc_api/json_samples/RdSAP-Schema-18.0/corpus.jsonl new file mode 100644 index 00000000..df51a9af --- /dev/null +++ b/backend/epc_api/json_samples/RdSAP-Schema-18.0/corpus.jsonl @@ -0,0 +1,1000 @@ +{"uprn": 100060708104, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO19 5EW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 2, "created_at": "2018-09-20 10:23:17.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15689}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "56, Keynsham Road", "assessment_type": "RdSAP", "completion_date": "2018-09-20", "inspection_date": "2018-09-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.5, "quantity": "metres"}}, "total_floor_area": 45, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 44.72, "quantity": "square metres"}, "party_wall_length": {"value": 8.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 188, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 188, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2296, "space_heating_existing_dwelling": 1678}, "energy_consumption_current": 155, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 155, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100120866927, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG9 1US", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "HENLEY-ON-THAMES", "built_form": 3, "created_at": "2018-07-17 08:17:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "4, Tilebarn Close", "assessment_type": "RdSAP", "completion_date": "2018-07-17", "inspection_date": "2018-07-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.74}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.9568, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 340, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 57.63, "quantity": "square metres"}, "party_wall_length": {"value": 5.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 391, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 321, "currency": "GBP"}, "hot_water_cost_current": {"value": 149, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 125, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1606, "impact_of_loft_insulation": -841, "space_heating_existing_dwelling": 4360}, "energy_consumption_current": 337, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 276, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100100689872, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NP20 5HP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWPORT", "built_form": 4, "created_at": "2018-05-23 07:45:09.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "43, Tewkesbury Walk", "assessment_type": "RdSAP", "completion_date": "2018-05-23", "inspection_date": "2018-05-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 56, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.8, "quantity": "square metres"}, "party_wall_length": {"value": 12.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 286, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 255, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1726, "space_heating_existing_dwelling": 3822}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 142, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100031770697, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST17 9NN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 2, "created_at": "2018-08-13 18:34:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "67, John Amery Drive", "assessment_type": "RdSAP", "completion_date": "2018-08-13", "inspection_date": "2018-07-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-08-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.02, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 35.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 502, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2178, "space_heating_existing_dwelling": 6936}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10002205518, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY1 2RG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHREWSBURY", "built_form": 3, "created_at": "2018-08-13 12:17:51.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10552}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "35, Glendower Court", "address_line_2": "Falstaff Street", "assessment_type": "RdSAP", "completion_date": "2018-08-13", "inspection_date": "2018-07-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-08-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 458, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 421, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2219, "space_heating_existing_dwelling": 5988}, "energy_consumption_current": 151, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 71, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200004771890, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO10 4BZ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "YORK", "built_form": 4, "created_at": "2018-10-30 09:35:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 13 Paragon House", "address_line_2": "Fawcett Street", "assessment_type": "RdSAP", "completion_date": "2018-10-30", "inspection_date": "2018-10-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 2.24}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-30", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.2192, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 340, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 62.68, "quantity": "square metres"}, "party_wall_length": {"value": 14.21, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 276, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 219, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 160, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 103, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1859, "space_heating_existing_dwelling": 2852}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 211, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100061801383, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN5 9JA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HENFIELD", "built_form": 1, "created_at": "2018-09-10 14:24:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17079}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "35, Furners Mead", "assessment_type": "RdSAP", "completion_date": "2018-09-10", "inspection_date": "2018-09-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15, "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 102.59, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 43.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 800, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 687, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2246, "space_heating_existing_dwelling": 11381}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "2.0.x", "energy_consumption_potential": 149, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100100073752, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF5 1AN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2018-07-10 15:10:44.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "40, Mayfield Avenue", "assessment_type": "RdSAP", "completion_date": "2018-07-10", "inspection_date": "2018-07-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.34, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.61, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 41.34, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.55, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.29, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 563, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2328, "impact_of_loft_insulation": -945, "impact_of_cavity_insulation": -1059, "impact_of_solid_wall_insulation": -825, "space_heating_existing_dwelling": 10256}, "energy_consumption_current": 212, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "3.05r03", "energy_consumption_potential": 93, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 72032731, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS6 2LN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 3, "created_at": "2018-06-25 20:06:51.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Burchett Place", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 157, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 31.2, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.68, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.71, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.78, "quantity": "metres"}, "total_floor_area": {"value": 41.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.71, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.78, "quantity": "metres"}, "total_floor_area": {"value": 39.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 1.78, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 4.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1209, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 750, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 350, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 109, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2447, "impact_of_loft_insulation": -855, "impact_of_solid_wall_insulation": -7550, "space_heating_existing_dwelling": 23097}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 125, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 10002422867, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU22 7UJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOKING", "built_form": 5, "created_at": "2018-11-15 14:27:13.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15689}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6 Tetten Hall", "address_line_2": "West Hill Road", "assessment_type": "RdSAP", "completion_date": "2018-11-15", "inspection_date": "2018-11-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-11-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 71.19, "quantity": "square metres"}, "party_wall_length": {"value": 10.77, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 164, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 83, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 164, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2170, "space_heating_existing_dwelling": 1128}, "energy_consumption_current": 89, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 89, "environmental_impact_current": 86, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "B", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 16, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100040003285, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL18 9EX", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "GUNNISLAKE", "built_form": 2, "created_at": "2018-02-13 16:30:31", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 3, "main_heating_number": 1, "main_heating_control": 2206, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 100882}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, radiators, electric", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Moorland Way", "assessment_type": "RdSAP", "completion_date": "2018-02-13", "inspection_date": "2018-02-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.92, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.26, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 306, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 416, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a39,000 - \u00a314,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 223, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3454, "space_heating_existing_dwelling": 7976}, "energy_consumption_current": 212, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 73, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 6098809, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [1]}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E14 8NG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2018-05-18 00:38:10.000000", "door_count": 1, "glazed_area": 2, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8267}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 246, Waterman Building", "address_line_2": "14, Westferry Road", "assessment_type": "RdSAP", "completion_date": "2018-05-18", "inspection_date": "2018-05-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 7, "heat_loss_corridor": 2, "unheated_corridor_length": 10.78}, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 25.333, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 88.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 35.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 206, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 199, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 82}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2535, "space_heating_existing_dwelling": 1840}, "energy_consumption_current": 106, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 91, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 19, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100040503499, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PL3 4NP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 2, "created_at": "2018-03-13 12:31:55.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "108, Weston Park Road", "assessment_type": "RdSAP", "completion_date": "2018-03-13", "inspection_date": "2018-03-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.88, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.73, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 743, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 138, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2272, "impact_of_loft_insulation": -1249, "impact_of_cavity_insulation": -1730, "space_heating_existing_dwelling": 11201}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100120388419, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GL51 3BP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "CHELTENHAM", "built_form": 4, "created_at": "2018-10-22 18:10:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Lilac Close", "address_line_2": "Up Hatherley", "assessment_type": "RdSAP", "completion_date": "2018-10-22", "inspection_date": "2018-10-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27, "quantity": "square metres"}, "party_wall_length": {"value": 7.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 27, "quantity": "square metres"}, "party_wall_length": {"value": 7.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.32, "quantity": "square metres"}, "party_wall_length": 3.59, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 372, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2258, "impact_of_loft_insulation": -438, "space_heating_existing_dwelling": 5896}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 62, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100062108870, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN1 2LU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TUNBRIDGE WELLS", "built_form": 4, "created_at": "2018-09-26 16:50:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8440}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "15, Crescent Road", "assessment_type": "RdSAP", "completion_date": "2018-09-26", "inspection_date": "2018-09-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.2}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.584, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 45.15, "quantity": "square metres"}, "party_wall_length": {"value": 15.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 454, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 311, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1624, "impact_of_solid_wall_insulation": -1391, "space_heating_existing_dwelling": 6308}, "energy_consumption_current": 323, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "3.07r02", "energy_consumption_potential": 201, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031434272, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG21 0JD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANSFIELD", "built_form": 2, "created_at": "2018-06-25 13:05:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16732}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Python Hill Road", "address_line_2": "Rainworth", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 36.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 538, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 464, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2085, "space_heating_existing_dwelling": 8848}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 123, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100040026083, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TR11 5NF", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "FALMOUTH", "built_form": 2, "created_at": "2018-08-09 15:01:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "13, Bonython Close", "address_line_2": "Mylor Bridge", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-08-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 683, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 268, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 115, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 371, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 60}, {"sequence": 7, "typical_saving": {"value": 349, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.2, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 480, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 427, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1618, "space_heating_existing_dwelling": 4127}, "energy_consumption_current": 447, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 168, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10003183412, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CB24 6DS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 2, "created_at": "2018-09-19 18:33:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17384}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "18, Woodman Way", "address_line_2": "Milton", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.05, "quantity": "square metres"}, "party_wall_length": {"value": 7.33, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.53, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 30.05, "quantity": "square metres"}, "party_wall_length": {"value": 7.33, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 364, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 340, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1731, "impact_of_loft_insulation": -317, "space_heating_existing_dwelling": 5628}, "energy_consumption_current": 196, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 67, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100100859727, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL13 9PE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WREXHAM", "built_form": 3, "created_at": "2018-07-30 16:45:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15462}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "29, Glan Gors", "assessment_type": "RdSAP", "completion_date": "2018-07-30", "inspection_date": "2018-07-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 30.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.09, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 376, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 351, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2407, "space_heating_existing_dwelling": 5957}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 91, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021456493, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA4 6LQ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "RUISLIP", "built_form": 3, "created_at": "2018-05-22 21:45:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 402, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 0.5, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "60, Carmichael Close", "assessment_type": "RdSAP", "completion_date": "2018-05-22", "inspection_date": "2018-05-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 12.33}, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 28.9755, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 70.44, "quantity": "square metres"}, "party_wall_length": {"value": 4.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 180, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 180, "currency": "GBP"}, "hot_water_cost_current": {"value": 163, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1831, "space_heating_existing_dwelling": 1236}, "energy_consumption_current": 149, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 136, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "B", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 4510067998, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE4 5PD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 4, "created_at": "2018-10-26 11:40:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "49, Sidney Grove", "assessment_type": "RdSAP", "completion_date": "2018-10-26", "inspection_date": "2018-10-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 123, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-10-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.99, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.56, "quantity": "square metres"}, "party_wall_length": {"value": 21.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.82, "quantity": "metres"}, "total_floor_area": {"value": 59.15, "quantity": "square metres"}, "party_wall_length": {"value": 21.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 787, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 145, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 515, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 249, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 83}], "co2_emissions_potential": 2.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2294, "impact_of_solid_wall_insulation": -5311, "space_heating_existing_dwelling": 14348}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 93, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 4510082152, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE5 2AR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 2, "created_at": "2018-07-24 18:27:19.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Mill Hill Road", "assessment_type": "RdSAP", "completion_date": "2018-07-24", "inspection_date": "2018-07-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 8.64, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 553, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 479, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1840, "impact_of_loft_insulation": -586, "space_heating_existing_dwelling": 9998}, "energy_consumption_current": 298, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 155, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100081073449, "roofs": [{"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly secondary glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL6 0AX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 1, "created_at": "2018-05-12 14:39:01.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Acacias", "address_line_2": "Ellington Road", "address_line_3": "Taplow", "assessment_type": "RdSAP", "completion_date": "2018-05-12", "inspection_date": "2018-04-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 196, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 32.21, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.156, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.218, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 79.648, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 38.076, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.377, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.319, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 2407, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 14.0, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1658, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 402, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 42}, {"sequence": 3, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 45}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 49}], "co2_emissions_potential": 8.2, "energy_rating_potential": 62, "lighting_cost_potential": {"value": 97, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2871, "impact_of_solid_wall_insulation": -7271, "space_heating_existing_dwelling": 36387}, "energy_consumption_current": 389, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "2.0.x", "energy_consumption_potential": 236, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "E", "environmental_impact_potential": 49, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100061638736, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "GU21 3JU", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WOKING", "built_form": 5, "created_at": "2018-03-23 15:45:36.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "26, Bitterne Drive", "assessment_type": "RdSAP", "completion_date": "2018-03-23", "inspection_date": "2018-03-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 41, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-03-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.7, "quantity": "square metres"}, "party_wall_length": {"value": 9.11, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 20.7, "quantity": "square metres"}, "party_wall_length": {"value": 9.11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 559, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 216, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}, {"sequence": 8, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 95, "environmental_impact_rating": 81}], "co2_emissions_potential": 0.9, "energy_rating_potential": 95, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 240, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 195, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1729, "impact_of_loft_insulation": -299, "impact_of_cavity_insulation": -876, "space_heating_existing_dwelling": 3902}, "energy_consumption_current": 441, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 124, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200004674347, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX1 2JN", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "OXFORD", "built_form": 4, "created_at": "2018-08-07 10:46:04.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2706, "main_heating_category": 8, "main_heating_fraction": 1, "sap_main_heating_code": 421, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric underfloor heating", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "Maisonette 1", "address_line_2": "28, Walton Lane", "assessment_type": "RdSAP", "completion_date": "2018-08-07", "inspection_date": "2018-08-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-08-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 33.41, "wall_dry_lined": "N", "wall_thickness": 370, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.45, "quantity": "square metres"}, "party_wall_length": {"value": 5.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 20.44, "quantity": "square metres"}, "party_wall_length": {"value": 5.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 225, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 225, "currency": "GBP"}, "hot_water_cost_current": {"value": 158, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1612, "space_heating_existing_dwelling": 2469}, "energy_consumption_current": 323, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 305, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100071314435, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 45% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CV1 5GJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 6, "created_at": "2018-04-02 15:55:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Flat 10 Douglas House", "address_line_2": "Adelaide Street", "assessment_type": "RdSAP", "completion_date": "2018-04-02", "inspection_date": "2018-03-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.9, "quantity": "metres"}}, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.36, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 8, "wall_insulation_type": 5, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 21.48, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45.63, "quantity": "square metres"}, "party_wall_length": {"value": 11.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 484, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 487, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.7, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1809, "space_heating_existing_dwelling": 8355}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 228, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100021980438, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SE8 4JE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-11-01 14:06:48.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "9a Lind Street", "assessment_type": "RdSAP", "completion_date": "2018-11-01", "inspection_date": "2018-10-25", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3}, "total_floor_area": 49, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-11-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.1, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.4, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.38, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 417, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2041, "impact_of_solid_wall_insulation": -2385, "space_heating_existing_dwelling": 6917}, "energy_consumption_current": 284, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.08r07", "energy_consumption_potential": 157, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 72192399, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LS6 3NY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 2, "created_at": "2018-10-30 18:48:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "63, St. Annes Road", "assessment_type": "RdSAP", "completion_date": "2018-10-30", "inspection_date": "2018-10-30", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 119, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 32.34, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "C"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.45, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 26.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 49.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1216, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 708, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2028, "impact_of_loft_insulation": -969, "impact_of_cavity_insulation": -2926, "space_heating_existing_dwelling": 23686}, "energy_consumption_current": 332, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 142, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100110199211, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 58% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TS20 2EU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKTON-ON-TEES", "built_form": 2, "created_at": "2018-07-21 16:27:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, Southfield Road", "assessment_type": "RdSAP", "completion_date": "2018-07-21", "inspection_date": "2018-07-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 15.63, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.29, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 40.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1255, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.2, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 972, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 191, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 60}], "co2_emissions_potential": 4.5, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2245, "impact_of_loft_insulation": -1997, "impact_of_cavity_insulation": -310, "impact_of_solid_wall_insulation": -4098, "space_heating_existing_dwelling": 22602}, "energy_consumption_current": 400, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 246, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200004827727, "roofs": [{"description": {"value": "Thatched", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cob, as built", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DT2 8LF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DORCHESTER", "built_form": 2, "created_at": "2018-09-04 13:33:42", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17117}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "75", "address_line_2": "East Knighton", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 6, "wall_construction": 9, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.904, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.991, "quantity": "square metres"}, "party_wall_length": {"value": 4.285, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.919, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 1.987, "quantity": "metres"}, "total_floor_area": {"value": 39.832, "quantity": "square metres"}, "party_wall_length": {"value": 4.545, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.073, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.202, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.292, "quantity": "square metres"}, "party_wall_length": {"value": 2.787, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.919, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 768, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 576, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.2, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2103, "impact_of_cavity_insulation": -690, "space_heating_existing_dwelling": 12143}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "2.0.x", "energy_consumption_potential": 184, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": null, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN37 6HU", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ST. LEONARDS-ON-SEA", "built_form": 2, "created_at": "2018-10-31 19:33:08.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Basement flat", "language_code": 1, "property_type": 2, "address_line_1": "Basement Flat 3", "address_line_2": "30 Chapel Park Road", "assessment_type": "RdSAP", "completion_date": "2018-10-31", "inspection_date": "2018-10-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 2, "unheated_corridor_length": 1.2}, "total_floor_area": 23, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-10-31", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.86, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 643, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 21, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 145, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 193, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 162, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 153, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 836, "impact_of_solid_wall_insulation": -1754, "space_heating_existing_dwelling": 3882}, "energy_consumption_current": 651, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 338, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 110, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100040804281, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH15 3SE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 1, "created_at": "2018-09-06 18:12:37.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "132, Dorchester Road", "address_line_2": "Oakdale", "assessment_type": "RdSAP", "completion_date": "2018-09-06", "inspection_date": "2018-09-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 324, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.49, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 656, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 440, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a31,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 7, "typical_saving": {"value": 334, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2051, "impact_of_loft_insulation": -544, "impact_of_cavity_insulation": -1901, "space_heating_existing_dwelling": 9689}, "energy_consumption_current": 308, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 93, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 41035311, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L22 7SA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-02-05 21:41:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230001, "number_of_heaters": 1, "high_heat_retention": "true"}, {"index_number": 230003, "number_of_heaters": 1, "high_heat_retention": "true"}, {"index_number": 230004, "number_of_heaters": 2, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 0.7, "sap_main_heating_code": 409, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.3, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Gordon Avenue", "address_line_2": "Waterloo", "assessment_type": "RdSAP", "completion_date": "2018-02-05", "inspection_date": "2018-02-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 41.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 917, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.2, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Controls for high heat retention storage heaters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 665, "currency": "GBP"}, "hot_water_cost_current": {"value": 312, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 35}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 37}, {"sequence": 3, "typical_saving": {"value": 176, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 145, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 198, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 159, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 336, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2190, "impact_of_cavity_insulation": -558, "impact_of_solid_wall_insulation": -2353, "space_heating_existing_dwelling": 11175}, "energy_consumption_current": 472, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 131, "environmental_impact_current": 33, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100061148735, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 54% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CT8 8EL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WESTGATE-ON-SEA", "built_form": 2, "created_at": "2018-07-12 13:33:00.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "20, St. Lukes Close", "assessment_type": "RdSAP", "completion_date": "2018-07-12", "inspection_date": "2018-07-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 43.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 750, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 628, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 330, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2162, "impact_of_loft_insulation": -3477, "impact_of_cavity_insulation": -2217, "space_heating_existing_dwelling": 13561}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 156, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100070419251, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B23 7PR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2018-07-11 15:29:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "12, Kegworth Road", "assessment_type": "RdSAP", "completion_date": "2018-07-11", "inspection_date": "2018-07-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.34, "quantity": "square metres"}, "party_wall_length": {"value": 7.17, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 39.34, "quantity": "square metres"}, "party_wall_length": {"value": 7.17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.13, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 790, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 487, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1990, "impact_of_loft_insulation": -416, "impact_of_solid_wall_insulation": -5605, "space_heating_existing_dwelling": 14364}, "energy_consumption_current": 305, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 114, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100061426566, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 93% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH4 2PA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DORKING", "built_form": 2, "created_at": "2018-05-19 17:40:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "81, Rough Rew", "assessment_type": "RdSAP", "completion_date": "2018-05-19", "inspection_date": "2018-05-19", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 8}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": "NR", "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.96, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 245, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 20.93, "quantity": "square metres"}, "party_wall_length": {"value": 1.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 3.62, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 20.93, "quantity": "square metres"}, "party_wall_length": {"value": 1.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 8.79, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 400, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 20.92, "quantity": "square metres"}, "party_wall_length": {"value": 1.51, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 93, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 344, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 304, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1976, "impact_of_cavity_insulation": -346, "impact_of_solid_wall_insulation": -899, "space_heating_existing_dwelling": 5143}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 161, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 14, "multiple_glazed_proportion_nr": "NR", "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100021292934, "roofs": [{"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 30% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HA2 8LN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 4, "created_at": "2018-10-27 17:55:17.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "40, Wargrave Road", "assessment_type": "RdSAP", "completion_date": "2018-10-27", "inspection_date": "2018-10-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.74, "quantity": "square metres"}, "party_wall_length": {"value": 14.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 38.74, "quantity": "square metres"}, "party_wall_length": {"value": 14.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 596, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 324, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2085, "impact_of_loft_insulation": -3355, "impact_of_solid_wall_insulation": -2265, "space_heating_existing_dwelling": 10987}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 56, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100011601649, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M34 6AR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-04-12 08:52:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "16, Mount Pleasant Road", "address_line_2": "Denton", "assessment_type": "RdSAP", "completion_date": "2018-04-12", "inspection_date": "2018-04-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.71, "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.63, "quantity": "square metres"}, "party_wall_length": {"value": 6.28, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 26.63, "quantity": "square metres"}, "party_wall_length": {"value": 6.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 563, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 500, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1753, "impact_of_loft_insulation": -2292, "space_heating_existing_dwelling": 8737}, "energy_consumption_current": 329, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 182, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100050984205, "roofs": [{"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 31% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S11 7JQ", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SHEFFIELD", "built_form": 2, "created_at": "2018-04-06 14:17:28", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8511}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "41, Greystones Drive", "assessment_type": "RdSAP", "completion_date": "2018-04-06", "inspection_date": "2018-04-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.73, "quantity": "square metres"}, "party_wall_length": {"value": 6.35, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 47.86, "quantity": "square metres"}, "party_wall_length": {"value": 6.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}], "low_energy_lighting": 31, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 867, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 606, "currency": "GBP"}, "hot_water_cost_current": {"value": 301, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 172, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 128, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5252, "impact_of_cavity_insulation": -3106, "space_heating_existing_dwelling": 13403}, "energy_consumption_current": 353, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 138, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10003954810, "roofs": [{"description": "Pitched, 400+ mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA5 0AP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARNFORTH", "built_form": 1, "created_at": "2018-04-04 17:42:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "28, Inglemere Close", "address_line_2": "Arnside", "assessment_type": "RdSAP", "completion_date": "2018-04-04", "inspection_date": "2018-04-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 90.37, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 706, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 601, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "space_heating_existing_dwelling": 10029}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 124, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100061560369, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 14% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "GU18 5LF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIGHTWATER", "built_form": 3, "created_at": "2018-04-03 14:23:08.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1964}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Alsford Close", "assessment_type": "RdSAP", "completion_date": "2018-04-03", "inspection_date": "2018-04-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-04-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 30.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 373, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2608, "space_heating_existing_dwelling": 4711}, "energy_consumption_current": 242, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 49, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100050422351, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 27% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HG5 0JL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KNARESBOROUGH", "built_form": 1, "created_at": "2018-03-15 16:33:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "17, Whincup Grove", "assessment_type": "RdSAP", "completion_date": "2018-03-15", "inspection_date": "2018-03-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 39.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.32, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.88, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 804, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 678, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2297, "impact_of_loft_insulation": -468, "space_heating_existing_dwelling": 12099}, "energy_consumption_current": 293, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 170, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100030941246, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 82% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE9 1HH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAMFORD", "built_form": 4, "created_at": "2018-10-22 15:22:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "36, Edinburgh Road", "assessment_type": "RdSAP", "completion_date": "2018-10-22", "inspection_date": "2018-10-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.13, "quantity": "square metres"}, "party_wall_length": {"value": 11.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 42.13, "quantity": "square metres"}, "party_wall_length": {"value": 11.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 423, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 366, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1902, "space_heating_existing_dwelling": 7075}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 65, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100060777542, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN23 5PD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHFORD", "built_form": 4, "created_at": "2018-02-17 21:39:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "179, Beaver Lane", "assessment_type": "RdSAP", "completion_date": "2018-02-17", "inspection_date": "2018-02-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.77, "quantity": "square metres"}, "party_wall_length": {"value": 6.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 420, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 335, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.9, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1748, "impact_of_loft_insulation": -908, "space_heating_existing_dwelling": 6910}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 182, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100010642251, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 45% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PR25 3EE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEYLAND", "built_form": 2, "created_at": "2018-07-26 17:59:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "23, Nelson Avenue", "assessment_type": "RdSAP", "completion_date": "2018-07-26", "inspection_date": "2018-07-26", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-07-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.54, "quantity": "square metres"}, "party_wall_length": {"value": 3.71, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 22.52, "quantity": "square metres"}, "party_wall_length": {"value": 3.71, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.21, "quantity": "square metres"}, "party_wall_length": {"value": 2.67, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 16.21, "quantity": "square metres"}, "party_wall_length": {"value": 2.67, "quantity": "metres"}, "heat_loss_perimeter": {"value": 0.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 10.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.03, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.52, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 2.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 678, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 584, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2386, "impact_of_loft_insulation": -240, "impact_of_cavity_insulation": -1376, "space_heating_existing_dwelling": 11439}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 127, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100070299531, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B9 5PG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-07-21 10:26:03.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8789}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "644, Bordesley Green", "assessment_type": "RdSAP", "completion_date": "2018-07-21", "inspection_date": "2018-07-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-07-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.23, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.9, "quantity": "metres"}, "total_floor_area": {"value": 37.23, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 907, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 419, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2544, "impact_of_loft_insulation": -3086, "impact_of_solid_wall_insulation": -5316, "space_heating_existing_dwelling": 16033}, "energy_consumption_current": 405, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010854223, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BL2 4ND", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BOLTON", "built_form": 1, "created_at": "2018-08-18 16:17:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9510}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "178, Bradshaw Meadows", "assessment_type": "RdSAP", "completion_date": "2018-08-18", "inspection_date": "2018-08-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 151, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-08-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 80.37, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 46.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 70.68, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 37.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1099, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 140, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 809, "currency": "GBP"}, "hot_water_cost_current": {"value": 207, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 189, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 377, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3671, "impact_of_loft_insulation": -1045, "space_heating_existing_dwelling": 17082}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 139, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100100055858, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 69% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF23 5AE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2018-11-15 09:51:52.000000", "door_count": 2, "glazed_area": 4, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "sap_windows": [{"orientation": 6, "window_area": {"value": 0.95, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"orientation": 6, "window_area": {"value": 2.51, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"orientation": 6, "window_area": {"value": 2.39, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 2.16, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 0.89, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "false", "orientation": 2, "window_area": {"value": 7.1, "quantity": "square metres"}, "window_type": 2, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "false", "orientation": 2, "window_area": {"value": 0.82, "quantity": "square metres"}, "window_type": 2, "glazing_type": 3, "window_location": 2}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 1.52, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 2}, {"pvc_frame": "false", "orientation": 2, "window_area": {"value": 0.91, "quantity": "square metres"}, "window_type": 2, "glazing_type": 3, "window_location": 3}, {"pvc_frame": "false", "orientation": 2, "window_area": {"value": 0.38, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 3}, {"orientation": 6, "window_area": {"value": 2.02, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"orientation": 6, "window_area": {"value": 4.9, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 1.57, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 2}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 1.52, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 4}, {"orientation": 2, "window_area": {"value": 0.29, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 4}, {"orientation": 8, "window_area": {"value": 0.52, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 4}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "26, Waterloo Road", "assessment_type": "RdSAP", "completion_date": "2018-11-15", "inspection_date": "2018-11-14", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 163, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-11-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.06, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.51, "quantity": "square metres"}, "party_wall_length": {"value": 17.09, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 62.51, "quantity": "square metres"}, "party_wall_length": {"value": 17.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.22, "quantity": "square metres"}, "party_wall_length": {"value": 2.23, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.73, "quantity": "square metres"}, "party_wall_length": {"value": 3.07, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.16, "quantity": "square metres"}, "party_wall_length": {"value": 2.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 9.16, "quantity": "square metres"}, "party_wall_length": {"value": 2.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1178, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 854, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 69, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2261, "impact_of_loft_insulation": -2054, "impact_of_solid_wall_insulation": -4346, "space_heating_existing_dwelling": 19853}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 55, "calculation_software_version": "3.08r07", "energy_consumption_potential": 126, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10002639999, "roofs": [{"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DT9 6SN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SHERBORNE", "built_form": 2, "created_at": "2018-02-10 15:03:59", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15096}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "299", "address_line_2": "Silverlake", "assessment_type": "RdSAP", "completion_date": "2018-02-10", "inspection_date": "2018-02-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 193, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 58.1, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.23, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 67.23, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1391, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 687, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 357, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 79}], "co2_emissions_potential": 3.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 97, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3508, "impact_of_loft_insulation": -773, "impact_of_solid_wall_insulation": -6417, "space_heating_existing_dwelling": 26826}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 38, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100020982563, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SE18 1SZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-02-21 23:02:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1750}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Leghorn Road", "assessment_type": "RdSAP", "completion_date": "2018-02-21", "inspection_date": "2018-02-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.4, "quantity": "square metres"}, "party_wall_length": {"value": 13.54, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 30.79, "quantity": "square metres"}, "party_wall_length": {"value": 14.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.77, "quantity": "square metres"}, "party_wall_length": {"value": 4.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 10.77, "quantity": "square metres"}, "party_wall_length": {"value": 4.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 708, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2133, "impact_of_loft_insulation": -1127, "impact_of_solid_wall_insulation": -2646, "space_heating_existing_dwelling": 10345}, "energy_consumption_current": 284, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 93, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100021517739, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TW13 6RF", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FELTHAM", "built_form": 4, "created_at": "2018-07-25 14:07:58.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2304, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "85, Bear Road", "assessment_type": "RdSAP", "completion_date": "2018-07-25", "inspection_date": "2018-07-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 76, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37.8, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37.8, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 331, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 331, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.3, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2223, "space_heating_existing_dwelling": 4409}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 173, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100050351029, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BD23 2SA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SKIPTON", "built_form": 3, "created_at": "2018-06-06 17:43:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16931}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "16, Crag View Road", "assessment_type": "RdSAP", "completion_date": "2018-06-06", "inspection_date": "2018-06-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-06-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.92, "quantity": "square metres"}, "party_wall_length": {"value": 5.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 35.92, "quantity": "square metres"}, "party_wall_length": {"value": 5.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 777, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 711, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2024, "space_heating_existing_dwelling": 12478}, "energy_consumption_current": 351, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 229, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 38267609, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L8 5RX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2018-06-06 18:34:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 414", "address_line_2": "14, Plaza Boulevard", "assessment_type": "RdSAP", "completion_date": "2018-06-06", "inspection_date": "2018-06-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.6, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 63, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 183, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 112, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 162, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 88}], "hot_water_cost_potential": {"value": 151, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1862, "space_heating_existing_dwelling": 1247}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 168, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10093143505, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 77% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ2 5NU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TORQUAY", "built_form": 1, "created_at": "2018-11-19 20:07:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 8, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2109, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Waverley House", "address_line_2": "St. Lukes Road", "assessment_type": "RdSAP", "completion_date": "2018-11-19", "inspection_date": "2018-11-16", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 578, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 18, "pvc_window_frames": "true", "registration_date": "2018-11-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 440, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.92, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 52.8, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 20.6, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 52.8, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 20.6, "quantity": "metres"}}, {"floor": 3, "room_height": {"value": 2.1, "quantity": "metres"}, "total_floor_area": {"value": 51.45, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 700, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.7, "quantity": "metres"}, "total_floor_area": {"value": 75.7, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 18.43, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 3.55, "quantity": "metres"}, "total_floor_area": {"value": 67.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.7, "quantity": "metres"}, "total_floor_area": {"value": 60.64, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 1, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.36, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 4", "wall_dry_lined": "Y", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.67, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 77, "solar_water_heating": "N", "habitable_room_count": 18, "heating_cost_current": {"value": 4031, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 23, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 226, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and boiler energy manager", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 2116, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 65, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 1152, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 486, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 72}], "co2_emissions_potential": 11, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 229, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 136, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3197, "impact_of_loft_insulation": -604, "impact_of_solid_wall_insulation": -21344, "space_heating_existing_dwelling": 73564}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 63, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 56, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 43} +{"uprn": 100030069984, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NG16 6LZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-09-25 20:44:04.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8872}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "1, Lime Close", "address_line_2": "Pinxton", "assessment_type": "RdSAP", "completion_date": "2018-09-25", "inspection_date": "2018-09-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.6, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.29, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 372, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 334, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2410, "space_heating_existing_dwelling": 5868}, "energy_consumption_current": 245, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 90, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100120397367, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly secondary glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [10]}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL51 3QF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHELTENHAM", "built_form": 1, "created_at": "2018-02-23 18:09:03.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Sefton Walk", "address_line_2": "Up Hatherley", "assessment_type": "RdSAP", "completion_date": "2018-02-23", "inspection_date": "2018-02-23", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 129, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-02-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 26.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 69.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.89, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 846, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 655, "currency": "GBP"}, "hot_water_cost_current": {"value": 196, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 188, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 295, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3144, "impact_of_loft_insulation": -426, "space_heating_existing_dwelling": 11711}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 92, "calculation_software_version": "3.04r01", "energy_consumption_potential": 116, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 6069606, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E14 2DT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-02-25 18:06:15.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8867}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 18 Keel Court", "address_line_2": "11, Newport Avenue", "assessment_type": "RdSAP", "completion_date": "2018-02-25", "inspection_date": "2018-02-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 8.08}, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-02-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.7152, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 73.85, "quantity": "square metres"}, "party_wall_length": {"value": 8.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 254, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 256, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 121, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2538, "space_heating_existing_dwelling": 3167}, "energy_consumption_current": 135, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 131, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10093567926, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO16 7FY", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 2, "created_at": "2018-04-22 13:05:09", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "16 Bassett Heath Avenue", "assessment_type": "RdSAP", "completion_date": "2018-04-22", "inspection_date": "2018-04-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 34, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-04-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 3, "peak_power": {"value": 0.57, "quantity": "kW"}, "orientation": 4, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.98, "quantity": "square metres"}, "party_wall_length": {"value": 6.13, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 233, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 195, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1914, "space_heating_existing_dwelling": 2582}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 173, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090098395, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PE28 2TN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUNTINGDON", "built_form": 3, "created_at": "2018-06-10 18:17:43.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "17, Forge Way", "address_line_2": "Warboys", "assessment_type": "RdSAP", "completion_date": "2018-06-10", "inspection_date": "2018-06-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.88, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 352, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 299, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1764, "space_heating_existing_dwelling": 4927}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 64, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 72653415, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS10 4GH", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LEEDS", "built_form": 5, "created_at": "2018-06-07 20:47:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "6, New Forest Way", "assessment_type": "RdSAP", "completion_date": "2018-06-07", "inspection_date": "2018-06-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.02, "quantity": "metres"}}, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.3766, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.56, "quantity": "square metres"}, "party_wall_length": {"value": 13.72, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 275, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 152, "currency": "GBP"}, "hot_water_cost_current": {"value": 295, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 343, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1829, "space_heating_existing_dwelling": 1707}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 228, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 250018747, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BA4 5GB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SHEPTON MALLET", "built_form": 2, "created_at": "2018-03-06 09:41:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Misburg Close", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-03-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.88, "quantity": "square metres"}, "party_wall_length": {"value": 7.75, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 34.88, "quantity": "square metres"}, "party_wall_length": {"value": 7.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.75, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 509, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 301, "currency": "GBP"}, "hot_water_cost_current": {"value": 225, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 30, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 145, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 8, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 9, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 132, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3403, "space_heating_existing_dwelling": 6633}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 48, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 2827, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS10 7JB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2018-11-22 12:37:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9569}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "253, Passage Road", "assessment_type": "RdSAP", "completion_date": "2018-11-22", "inspection_date": "2018-11-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 294, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.83, "quantity": "square metres"}, "party_wall_length": {"value": 10.52, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 508, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 354, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1973, "impact_of_loft_insulation": -657, "space_heating_existing_dwelling": 7269}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 71, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100040533210, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TQ4 7DB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PAIGNTON", "built_form": 2, "created_at": "2018-10-02 14:03:11.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "14, St. Marys Park", "assessment_type": "RdSAP", "completion_date": "2018-10-02", "inspection_date": "2018-10-02", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 35, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-10-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.1, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 367, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 247, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}, {"sequence": 5, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 92, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.1, "energy_rating_potential": 92, "lighting_cost_potential": {"value": 28, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 46, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1483, "impact_of_solid_wall_insulation": -1795, "space_heating_existing_dwelling": 5521}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 8, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10023726590, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CW5 8DX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "NANTWICH", "built_form": 1, "created_at": "2018-09-25 16:23:40.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 130, "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Flag Lane", "address_line_2": "Aston", "assessment_type": "RdSAP", "completion_date": "2018-09-25", "inspection_date": "2018-09-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.93, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33.3, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 23.7, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "50mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 425, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 378, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 98, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 98, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2105, "space_heating_existing_dwelling": 9041}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": -29, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 202064815, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW10 2UN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-04-24 15:44:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "28, Neasden Lane", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-18", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.52, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 360, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.12, "quantity": "square metres"}, "party_wall_length": {"value": 19.25, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.52, "quantity": "square metres"}, "party_wall_length": {"value": 0.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 299, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 299, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1773, "impact_of_solid_wall_insulation": -317, "space_heating_existing_dwelling": 4182}, "energy_consumption_current": 149, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 39075257, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WA9 4AQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. HELENS", "built_form": 2, "created_at": "2018-06-18 16:43:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 5, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15701}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "305, Walkers Lane", "address_line_2": "Sutton Manor", "assessment_type": "RdSAP", "completion_date": "2018-06-18", "inspection_date": "2018-06-14", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, anthracite", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.2, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 37.2, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.8, "quantity": "square metres"}, "party_wall_length": 3.92, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.01, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 9.8, "quantity": "square metres"}, "party_wall_length": 3.92, "heat_loss_perimeter": {"value": 6.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.43, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.83, "quantity": "square metres"}, "party_wall_length": 4.33, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 946, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 651, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 251, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2277, "impact_of_loft_insulation": -2408, "impact_of_solid_wall_insulation": -5686, "space_heating_existing_dwelling": 17636}, "energy_consumption_current": 263, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 130, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100050551455, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "YO32 5UL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 1, "created_at": "2018-06-14 11:52:27.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "1 The Mews", "address_line_2": "Flaxton Road", "address_line_3": "Strensall", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 245, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 10, "pvc_window_frames": "false", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 120.31, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 56.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 124.73, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 57.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 1930, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 195, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1412, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": 210, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 76}], "co2_emissions_potential": 5.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 110, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 87}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 639, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 131, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3026, "space_heating_existing_dwelling": 27665}, "energy_consumption_current": 253, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 111, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 54, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 40066968, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 64% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "L36 2QB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-03-01 22:00:14.000000", "door_count": 2, "glazed_area": 4, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1821}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 4.6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 6, "window_area": {"value": 5.1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 2, "window_area": {"value": 1.22, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "4a, Gentwood Parade", "assessment_type": "RdSAP", "completion_date": "2018-03-01", "inspection_date": "2018-03-01", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-03-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 235, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.43, "quantity": "square metres"}, "party_wall_length": {"value": 11.88, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 42.43, "quantity": "square metres"}, "party_wall_length": {"value": 11.88, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 235, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.15, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.09, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 2.31, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 0.89, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 2.31, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 0.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 833, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 624, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}], "co2_emissions_potential": 3.5, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 135, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2197, "impact_of_solid_wall_insulation": -2972, "space_heating_existing_dwelling": 13746}, "energy_consumption_current": 302, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 215, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10009430000, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "To external air, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DA11 9AH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRAVESEND", "built_form": 3, "created_at": "2018-12-19 23:10:16.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 7 Griffin Court", "address_line_2": "Black Eagle Drive", "address_line_3": "Northfleet", "assessment_type": "RdSAP", "completion_date": "2018-12-19", "inspection_date": "2018-12-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.06, "quantity": "metres"}}, "total_floor_area": 44, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-12-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 1, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.37, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 330, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.27, "quantity": "square metres"}, "party_wall_length": {"value": 6.43, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 22.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 201, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 201, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1610, "space_heating_existing_dwelling": 1948}, "energy_consumption_current": 141, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 141, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061162114, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN15 0QH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SEVENOAKS", "built_form": 1, "created_at": "2018-12-06 09:10:58.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2705, "main_heating_category": 11, "main_heating_fraction": 1, "sap_main_heating_code": 701, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric ceiling heating", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Newlands", "address_line_2": "The Street", "address_line_3": "Plaxtol", "assessment_type": "RdSAP", "completion_date": "2018-12-06", "inspection_date": "2018-12-04", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 183, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-12-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.27, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 74.27, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 7.07, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "G"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 4.91, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.32, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 5, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 1.58, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 3365, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12.6, "energy_rating_average": 60, "energy_rating_current": 27, "lighting_cost_current": {"value": 142, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Temperature zone control", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1745, "currency": "GBP"}, "hot_water_cost_current": {"value": 272, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 134, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 36}, {"sequence": 2, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 1207, "currency": "GBP"}, "indicative_cost": "\u00a33,200 - \u00a34,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 42}, {"sequence": 4, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 44}, {"sequence": 5, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 48}], "co2_emissions_potential": 8.9, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 142, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 1882, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 87}, {"sequence": 2, "typical_saving": {"value": 1807, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 131, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2653, "impact_of_loft_insulation": -339, "space_heating_existing_dwelling": 20079}, "energy_consumption_current": 396, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 277, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "F", "environmental_impact_potential": 48, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100020573894, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR5 2LF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COULSDON", "built_form": 1, "created_at": "2018-07-07 10:03:28", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16454}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "176, Coulsdon Road", "assessment_type": "RdSAP", "completion_date": "2018-07-07", "inspection_date": "2018-07-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 569, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 464, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2694, "impact_of_loft_insulation": -424, "space_heating_existing_dwelling": 8410}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 32131230, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B67 7BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SMETHWICK", "built_form": 4, "created_at": "2018-05-24 18:47:03.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17117}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "4, The Oaks", "address_line_2": "South Road", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.3, "quantity": "metres"}}, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.18, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 71.49, "quantity": "square metres"}, "party_wall_length": {"value": 9.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 429, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 277, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1938, "impact_of_loft_insulation": -825, "impact_of_solid_wall_insulation": -2584, "space_heating_existing_dwelling": 6835}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 127, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100060236532, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG21 5QL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BASINGSTOKE", "built_form": 6, "created_at": "2018-08-11 10:10:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9569}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "133, Normanton Road", "assessment_type": "RdSAP", "completion_date": "2018-08-11", "inspection_date": "2018-08-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.37, "quantity": "square metres"}, "party_wall_length": {"value": 13.43, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 27.37, "quantity": "square metres"}, "party_wall_length": {"value": 15.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.53, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 432, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 307, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1810, "space_heating_existing_dwelling": 6365}, "energy_consumption_current": 258, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 54, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100051283405, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD17 5SB", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SHIPLEY", "built_form": 4, "created_at": "2018-10-08 15:52:38.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "122, Glenwood Avenue", "address_line_2": "Baildon", "assessment_type": "RdSAP", "completion_date": "2018-10-08", "inspection_date": "2018-08-29", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.2, "quantity": "metres"}}, "total_floor_area": 50, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-10-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.496, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 58.37, "quantity": "square metres"}, "party_wall_length": {"value": 8.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 691, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 330, "currency": "GBP"}, "hot_water_cost_current": {"value": 361, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 285, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 270, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2506, "impact_of_loft_insulation": -784, "impact_of_cavity_insulation": -1654, "impact_of_solid_wall_insulation": -780, "space_heating_existing_dwelling": 7283}, "energy_consumption_current": 624, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 352, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010052389, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CW10 9PF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLEWICH", "built_form": 1, "created_at": "2018-10-12 09:44:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16397}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Stallard Way", "assessment_type": "RdSAP", "completion_date": "2018-10-12", "inspection_date": "2018-10-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 42.84, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.19, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.09, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 704, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 646, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2754, "impact_of_loft_insulation": -356, "space_heating_existing_dwelling": 10941}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 145, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B70 6NZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEST BROMWICH", "built_form": 4, "created_at": "2018-02-26 22:43:32.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17816}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat Over", "address_line_2": "95-97 High Street", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 130, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 64.77, "quantity": "square metres"}, "party_wall_length": {"value": 16.48, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 15.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.65, "quantity": "metres"}, "total_floor_area": {"value": 64.77, "quantity": "square metres"}, "party_wall_length": {"value": 8.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.96, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 576, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 576, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 3.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2302, "space_heating_existing_dwelling": 10336}, "energy_consumption_current": 150, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 150, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200002615915, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HR6 8PZ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LEOMINSTER", "built_form": 5, "created_at": "2018-05-05 12:50:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "18, Kenelm Court", "assessment_type": "RdSAP", "completion_date": "2018-05-05", "inspection_date": "2018-05-05", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 63.99, "quantity": "square metres"}, "party_wall_length": {"value": 5.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 1.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 675, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 53}], "co2_emissions_potential": 3.8, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 215, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 193, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1872, "impact_of_loft_insulation": -1346, "space_heating_existing_dwelling": 7535}, "energy_consumption_current": 452, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 337, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 53, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100110276533, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CA2 7NZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "CARLISLE", "built_form": 2, "created_at": "2018-06-18 18:00:12.000000", "door_count": 1, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "40, Coledale Meadows", "assessment_type": "RdSAP", "completion_date": "2018-06-18", "inspection_date": "2018-06-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2018-06-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.5, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 23.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 361, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 287, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 94, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 94, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 171, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 109, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1840, "space_heating_existing_dwelling": 3990}, "energy_consumption_current": 356, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 170, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 64014343, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF62 4JT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARRY", "built_form": 2, "created_at": "2018-06-24 21:39:06.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16093}], "immersion_heating_type": "NA", "secondary_heating_type": 613, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Cedar Road", "address_line_2": "St. Athan", "assessment_type": "RdSAP", "completion_date": "2018-06-24", "inspection_date": "2018-06-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.63, "quantity": "square metres"}, "party_wall_length": {"value": 6.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.61, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 34.92, "quantity": "square metres"}, "party_wall_length": {"value": 8.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.83, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.42, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 624, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 501, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2452, "impact_of_loft_insulation": -764, "impact_of_cavity_insulation": -1975, "space_heating_existing_dwelling": 11433}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100070442492, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B11 2HU", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-06-22 15:12:51.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 603, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "56, Manor Farm Road", "assessment_type": "RdSAP", "completion_date": "2018-06-22", "inspection_date": "2018-06-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.1, "quantity": "square metres"}, "party_wall_length": {"value": 10.43, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 34.1, "quantity": "square metres"}, "party_wall_length": {"value": 10.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1312, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 596, "currency": "GBP"}, "hot_water_cost_current": {"value": 335, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 30}, {"sequence": 2, "typical_saving": {"value": 342, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 43}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 44}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 44}, {"sequence": 6, "typical_saving": {"value": 406, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 8, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 9, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 317, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 275, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 560, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2077, "impact_of_loft_insulation": -2962, "impact_of_solid_wall_insulation": -4781, "space_heating_existing_dwelling": 16692}, "energy_consumption_current": 576, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r03", "energy_consumption_potential": 156, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "F", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 100, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10091741468, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TA1 4DQ", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}, "post_town": "TAUNTON", "built_form": 4, "created_at": "2018-03-16 08:37:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 914, "water_heating_fuel": 29, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0.5, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9897}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Basement flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "17, Park Street", "assessment_type": "RdSAP", "completion_date": "2018-03-16", "inspection_date": "2018-03-14", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.1, "quantity": "metres"}}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-03-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.766, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.382, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.75, "quantity": "square metres"}, "party_wall_length": {"value": 16.11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 8.03, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.382, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.78, "quantity": "square metres"}, "party_wall_length": 5.76, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 265, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 246, "currency": "GBP"}, "hot_water_cost_current": {"value": 214, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.2, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3025, "impact_of_solid_wall_insulation": -386, "space_heating_existing_dwelling": 2444}, "energy_consumption_current": 456, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 370, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10002274031, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LU7 4RX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEIGHTON BUZZARD", "built_form": 3, "created_at": "2018-03-14 10:57:40.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "24, Reeve Close", "assessment_type": "RdSAP", "completion_date": "2018-03-14", "inspection_date": "2018-03-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 0.89, "quantity": "metres"}}, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-03-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.092, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.66, "quantity": "square metres"}, "party_wall_length": {"value": 16.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 204, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 204, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1929, "space_heating_existing_dwelling": 2010}, "energy_consumption_current": 109, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 109, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "B", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 19, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10011761917, "roofs": [{"description": "Pitched, 350 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SY21 8LH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WELSHPOOL", "built_form": 1, "created_at": "2018-03-12 20:05:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 127, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "9, Heritage Green", "address_line_2": "Forden", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-12", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 16.52, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 11.5}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.1, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 37.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 469, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 447, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 63}], "co2_emissions_potential": 3.1, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2556, "space_heating_existing_dwelling": 9272}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 151, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 250036973, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BA11 2EE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FROME", "built_form": 1, "created_at": "2018-01-19 10:42:45.000000", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8138}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Elmleigh", "address_line_2": "Berkley Road", "assessment_type": "RdSAP", "completion_date": "2018-01-19", "inspection_date": "2018-01-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "registration_date": "2018-01-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.66, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 35.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 65.66, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 35.82, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 809, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 683, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2304, "space_heating_existing_dwelling": 13219}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100031830478, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WV4 4TP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 1, "created_at": "2018-01-16 18:04:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "60, Springhill Park", "assessment_type": "RdSAP", "completion_date": "2018-01-16", "inspection_date": "2018-01-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.48, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.48, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 625, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 572, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2074, "space_heating_existing_dwelling": 10156}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 134, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100040542326, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ2 6JL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TORQUAY", "built_form": 2, "created_at": "2018-10-20 09:48:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17511}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "13, Drake Avenue", "assessment_type": "RdSAP", "completion_date": "2018-10-20", "inspection_date": "2018-10-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.66, "quantity": "square metres"}, "party_wall_length": {"value": 9.51, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 399, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1787, "impact_of_cavity_insulation": -1522, "space_heating_existing_dwelling": 8990}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 81, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": null, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW1 7RS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-12-24 09:38:04.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16643}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Second Floor Flat", "address_line_2": "29 Mornington Terrace", "assessment_type": "RdSAP", "completion_date": "2018-12-24", "inspection_date": "2018-12-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 5.89}, "total_floor_area": 28, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "false", "registration_date": "2018-12-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.6072, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 27.73, "quantity": "square metres"}, "party_wall_length": {"value": 12.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.78, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 206, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 24, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 166, "currency": "GBP"}, "hot_water_cost_current": {"value": 66, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 82}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 84}], "co2_emissions_potential": 0.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1397, "impact_of_solid_wall_insulation": -498, "space_heating_existing_dwelling": 1841}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 166, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100090365454, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SS7 4BU", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BENFLEET", "built_form": 1, "created_at": "2018-03-17 18:06:45.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "35, Rushbottom Lane", "assessment_type": "RdSAP", "completion_date": "2018-03-17", "inspection_date": "2018-03-17", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 93, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 54.09, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1075, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 231, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 36}, {"sequence": 2, "typical_saving": {"value": 420, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 9, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 159, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3283, "impact_of_loft_insulation": -407, "impact_of_solid_wall_insulation": -6436, "space_heating_existing_dwelling": 14728}, "energy_consumption_current": 414, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 89, "calculation_software_version": "3.04r01", "energy_consumption_potential": 75, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010862963, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BL6 5QE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 4, "created_at": "2018-08-31 05:42:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15200}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "145a, Chorley New Road", "address_line_2": "Horwich", "assessment_type": "RdSAP", "completion_date": "2018-08-31", "inspection_date": "2018-08-30", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 5.23}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 450, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 24.2, "quantity": "square metres"}, "party_wall_length": {"value": 9.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 12.9181, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 120, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 22.33, "quantity": "square metres"}, "party_wall_length": {"value": 6.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 512, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 453, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.5, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1645, "impact_of_loft_insulation": -4487, "impact_of_cavity_insulation": -322, "impact_of_solid_wall_insulation": -929, "space_heating_existing_dwelling": 8185}, "energy_consumption_current": 350, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 303, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100050025835, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 69% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO16 7LX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIDLINGTON", "built_form": 2, "created_at": "2018-01-24 09:29:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15695}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Queensgate", "assessment_type": "RdSAP", "completion_date": "2018-01-24", "inspection_date": "2018-01-23", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-01-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.87, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 51.87, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 599, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2181, "space_heating_existing_dwelling": 9916}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 124, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10002603927, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CB6 3FQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ELY", "built_form": 2, "created_at": "2018-01-22 09:05:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10261}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Morley Drive", "assessment_type": "RdSAP", "completion_date": "2018-01-22", "inspection_date": "2018-01-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-01-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 26.1, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "K", "roof_insulation_thickness": "100mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 8.25, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 17.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 8.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 370, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 376, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.1, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2353, "space_heating_existing_dwelling": 5783}, "energy_consumption_current": 134, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 61, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 77120985, "roofs": [{"description": "Flat, insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "M1 7AS", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-01-31 17:06:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 808 Orient House", "address_line_2": "Granby Row", "assessment_type": "RdSAP", "completion_date": "2018-01-31", "inspection_date": "2017-08-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 8, "heat_loss_corridor": 2, "unheated_corridor_length": 7.22}, "total_floor_area": 65, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-01-31", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "roof_u_value": 0.21, "wall_dry_lined": "N", "wall_thickness": 650, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.606, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 650, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 64.64, "quantity": "square metres"}, "party_wall_length": {"value": 15.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 912, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 553, "currency": "GBP"}, "hot_water_cost_current": {"value": 189, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 381, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 43}], "co2_emissions_potential": 4.6, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 564, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 471, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 153, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1880, "space_heating_existing_dwelling": 6399}, "energy_consumption_current": 416, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "sap_deselected_improvements": ["O", "P"], "calculation_software_version": "3.03r05", "energy_consumption_potential": 417, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 43, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 45123940, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SR4 0HH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2018-01-03 15:10:43", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10068}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "87, Padgate Road", "assessment_type": "RdSAP", "completion_date": "2018-01-03", "inspection_date": "2017-12-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-01-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 590, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 510, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2184, "space_heating_existing_dwelling": 10218}, "energy_consumption_current": 157, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "2.0.x", "energy_consumption_potential": 112, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100022805948, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW8 7HJ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-08-09 19:53:13.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5 Lords View", "address_line_2": "St. Johns Wood Road", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1, "quantity": "metres"}}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.5, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 130, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43, "quantity": "square metres"}, "party_wall_length": {"value": 11.1, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 497, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 196, "currency": "GBP"}, "hot_water_cost_current": {"value": 265, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 120, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.6, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 265, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1601, "impact_of_cavity_insulation": -997, "space_heating_existing_dwelling": 3004}, "energy_consumption_current": 343, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 214, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 6211415, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [6]}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "E1 1AB", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-10-17 15:59:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 12 Wool House", "address_line_2": "74, Back Church Lane", "assessment_type": "RdSAP", "completion_date": "2018-10-17", "inspection_date": "2018-10-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 6.99}, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-10-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 560, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.3623, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 89.26, "quantity": "square metres"}, "party_wall_length": {"value": 25.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 197, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 120, "currency": "GBP"}, "hot_water_cost_current": {"value": 344, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 242, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 333, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 280, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 88}], "hot_water_cost_potential": {"value": 154, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2079, "space_heating_existing_dwelling": 1189}, "energy_consumption_current": 134, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 118, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100061913946, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BN20 7EG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EASTBOURNE", "built_form": 2, "created_at": "2018-10-16 16:35:31.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "7 Granville Road", "assessment_type": "RdSAP", "completion_date": "2018-10-16", "inspection_date": "2018-10-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.18, "quantity": "metres"}}, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 30.031, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.95, "quantity": "metres"}, "total_floor_area": {"value": 98.71, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 43.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 712, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 321, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2362, "impact_of_solid_wall_insulation": -6164, "space_heating_existing_dwelling": 12128}, "energy_consumption_current": 251, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100030895941, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE11 4DB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SPALDING", "built_form": 1, "created_at": "2018-05-03 15:54:43", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17678}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "39, Station Road", "address_line_2": "Surfleet", "address_line_3": "Donington", "assessment_type": "RdSAP", "completion_date": "2018-05-03", "inspection_date": "2018-04-30", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 198, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "registration_date": "2018-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 44.86, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "D"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 170.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 62.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1731, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.5, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 944, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 423, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 198, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 618, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 87}], "co2_emissions_potential": 2.1, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 108, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 131, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2800, "impact_of_loft_insulation": -984, "impact_of_cavity_insulation": -3665, "space_heating_existing_dwelling": 33805}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 69, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": null, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N14 4XA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-03-23 07:00:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17816}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Top Floor Flat", "address_line_2": "173A Bramley Road", "assessment_type": "RdSAP", "completion_date": "2018-03-23", "inspection_date": "2018-03-22", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-03-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 42.26, "quantity": "square metres"}, "party_wall_length": {"value": 15.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 3, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 2.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.34, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 0.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 476, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 208, "currency": "GBP"}, "hot_water_cost_current": {"value": 76, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 204, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 81}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1616, "impact_of_cavity_insulation": -635, "space_heating_existing_dwelling": 7514}, "energy_consumption_current": 328, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 143, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200003645347, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DL5 4QG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWTON AYCLIFFE", "built_form": 2, "created_at": "2018-11-05 21:11:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "243, Aldfrid Place", "assessment_type": "RdSAP", "completion_date": "2018-11-05", "inspection_date": "2018-11-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.33, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 43.33, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 626, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "No time or thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 498, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1958, "space_heating_existing_dwelling": 10854}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 116, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 4510089407, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE6 5XY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 4, "created_at": "2018-10-23 07:44:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16797}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "58, King John Terrace", "assessment_type": "RdSAP", "completion_date": "2018-10-23", "inspection_date": "2018-10-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.91, "quantity": "metres"}, "total_floor_area": {"value": 69.48, "quantity": "square metres"}, "party_wall_length": {"value": 22.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 670, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 591, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}], "co2_emissions_potential": 3.4, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1995, "impact_of_loft_insulation": -6341, "impact_of_solid_wall_insulation": -2297, "space_heating_existing_dwelling": 12620}, "energy_consumption_current": 309, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 273, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100060315663, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO31 5GP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-09-04 17:08:24.000000", "door_count": 3, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "19, Bowcombe", "address_line_2": "Netley Abbey", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.32, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 37.32, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.02, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.76, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 424, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2459, "space_heating_existing_dwelling": 8314}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 81, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 45, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 35} +{"uprn": 200000560381, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE13 7TR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-02-07 20:49:54.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Basement flat", "language_code": 1, "property_type": 2, "address_line_1": "Basement Flat", "address_line_2": "8, Sandrock Road", "assessment_type": "RdSAP", "completion_date": "2018-02-07", "inspection_date": "2018-02-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 0}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": "NR", "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NI", "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 277, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 212, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1546, "impact_of_solid_wall_insulation": -787, "space_heating_existing_dwelling": 3151}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["W1", "T2", "Y", "X"], "calculation_software_version": "3.03r05", "energy_consumption_potential": 159, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "multiple_glazed_proportion_nr": "NR", "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 90125342, "roofs": [{"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DY6 8PF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KINGSWINFORD", "built_form": 4, "created_at": "2018-04-04 19:19:29.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat", "address_line_2": "36a, Madeley Road", "assessment_type": "RdSAP", "completion_date": "2018-04-04", "inspection_date": "2018-04-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 33, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-04-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 33.44, "quantity": "square metres"}, "party_wall_length": {"value": 12.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 481, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 311, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.5, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1459, "impact_of_cavity_insulation": -488, "space_heating_existing_dwelling": 6222}, "energy_consumption_current": 403, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 50, "calculation_software_version": "3.05r02", "energy_consumption_potential": 259, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 5300033264, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N5 2JH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-04-29 08:25:41.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17681}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "64b, Ferntower Road", "assessment_type": "RdSAP", "completion_date": "2018-04-29", "inspection_date": "2018-04-27", "extensions_count": 3, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-04-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 7, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.98, "quantity": "metres"}, "total_floor_area": {"value": 2.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 26.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.98, "quantity": "metres"}, "total_floor_area": {"value": 2.98, "quantity": "square metres"}, "party_wall_length": {"value": 5.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.58, "quantity": "metres"}, "total_floor_area": {"value": 13.78, "quantity": "square metres"}, "party_wall_length": {"value": 5.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 10.38, "quantity": "square metres"}, "party_wall_length": {"value": 3.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 8, "roof_construction": 1, "wall_construction": 5, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 25.27, "quantity": "square metres"}, "party_wall_length": {"value": 5.18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 314, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 89, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1920, "impact_of_solid_wall_insulation": -2050, "space_heating_existing_dwelling": 9189}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 128, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 100120893987, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 45% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG4 9EX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 2, "created_at": "2018-08-31 22:36:48.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1 Dysons Farm Cottages", "address_line_2": "Dysons Wood", "address_line_3": "Kidmore End", "assessment_type": "RdSAP", "completion_date": "2018-08-31", "inspection_date": "2018-08-31", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 4, "registration_date": "2018-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.21, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 28.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.21, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.86, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 1, "quantity": "metres"}, "total_floor_area": {"value": 0.01, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 824, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 372, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 241, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a31,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 88}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 156, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2656, "impact_of_loft_insulation": -292, "impact_of_solid_wall_insulation": -3915, "space_heating_existing_dwelling": 11295}, "energy_consumption_current": 422, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 77, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 3040018150, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NG2 6AJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2018-04-30 18:25:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10565}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 The Covers", "address_line_2": "Fox Road", "address_line_3": "West Bridgford", "assessment_type": "RdSAP", "completion_date": "2018-04-30", "inspection_date": "2018-04-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-04-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.54, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 415, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 305, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1677, "space_heating_existing_dwelling": 6062}, "energy_consumption_current": 279, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 197, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100091604122, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SS9 2BE", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LEIGH ON SEA", "built_form": 1, "created_at": "2018-03-08 09:58:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2 Glenmar Court", "address_line_2": "125 Glendale Gardens", "assessment_type": "RdSAP", "completion_date": "2018-03-08", "inspection_date": "2018-03-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 6.38}, "total_floor_area": 37, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-03-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.2482, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 240, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 25.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 470, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 279, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 54}], "co2_emissions_potential": 2.6, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 116, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 78}], "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1570, "space_heating_existing_dwelling": 5220}, "energy_consumption_current": 598, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 421, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 101, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100021228472, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N8 0EU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-07-27 20:27:11.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 17 Wordsworth", "address_line_2": "Sydney Road", "assessment_type": "RdSAP", "completion_date": "2018-07-27", "inspection_date": "2018-07-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 7.4}, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.02, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 60.68, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 477, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 477, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.7, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2075, "impact_of_loft_insulation": -5824, "space_heating_existing_dwelling": 8216}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 252, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200003343848, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO22 5AU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WHITBY", "built_form": 1, "created_at": "2018-10-11 19:37:49", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17192}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "High Burrows", "address_line_2": "Egton Grange", "assessment_type": "RdSAP", "completion_date": "2018-10-11", "inspection_date": "2018-10-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 276, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-10-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 53.53, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "50mm"}, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 111, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 42.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 111, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 42.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2495, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 18, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 153, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1115, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 664, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 179, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 9, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 5.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 157, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3057, "impact_of_loft_insulation": -1159, "impact_of_solid_wall_insulation": -14099, "space_heating_existing_dwelling": 55118}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 71, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10000271841, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 98% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX11 1NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "OTTERY ST. MARY", "built_form": 1, "created_at": "2018-08-23 08:49:34", "door_count": 3, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 3, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15231}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Woodhayes", "address_line_2": "Brackendown", "address_line_3": "West Hill", "assessment_type": "RdSAP", "completion_date": "2018-08-23", "inspection_date": "2018-08-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 360, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "false", "registration_date": "2018-08-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 148.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 43.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 154.8, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 50.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 98, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1332, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 138, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1247, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "co2_emissions_potential": 8.3, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 138, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3085, "space_heating_existing_dwelling": 29988}, "energy_consumption_current": 123, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 95, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 49, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 48} +{"uprn": 21116086, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU1 2QX", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HULL", "built_form": 3, "created_at": "2018-12-13 07:11:56.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "11 Merchants Warehouse", "address_line_2": "Robinson Row", "assessment_type": "RdSAP", "completion_date": "2018-12-13", "inspection_date": "2018-12-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-12-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 540, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 58.6, "quantity": "square metres"}, "party_wall_length": {"value": 8.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 82, "currency": "GBP"}, "hot_water_cost_current": {"value": 196, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 178, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 227, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 175, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 164, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1906, "impact_of_solid_wall_insulation": -1231, "space_heating_existing_dwelling": 3332}, "energy_consumption_current": 289, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.08r07", "energy_consumption_potential": 159, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100091077500, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP1 5DG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "IPSWICH", "built_form": 4, "created_at": "2018-06-22 13:31:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "160, Waveney Road", "assessment_type": "RdSAP", "completion_date": "2018-06-22", "inspection_date": "2018-06-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.74, "quantity": "square metres"}, "party_wall_length": {"value": 9.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 19.74, "quantity": "square metres"}, "party_wall_length": {"value": 9.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.1, "quantity": "square metres"}, "party_wall_length": {"value": 11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.6, "quantity": "metres"}, "total_floor_area": {"value": 23.1, "quantity": "square metres"}, "party_wall_length": {"value": 11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 675, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 425, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2156, "impact_of_loft_insulation": -1716, "impact_of_cavity_insulation": -852, "space_heating_existing_dwelling": 11109}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100061105199, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT7 9TG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRCHINGTON", "built_form": 1, "created_at": "2018-08-10 16:23:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16376}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "10, Dorset Gardens", "assessment_type": "RdSAP", "completion_date": "2018-08-10", "inspection_date": "2018-08-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 105, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 317, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.35, "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 82.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 38.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 291, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 588, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 526, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 330, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2146, "impact_of_cavity_insulation": -243, "space_heating_existing_dwelling": 10804}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 98, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100071358113, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WV10 9TL", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WOLVERHAMPTON", "built_form": 4, "created_at": "2018-12-10 23:07:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "22, Malvern Court", "address_line_2": "Whetstone Grove", "assessment_type": "RdSAP", "completion_date": "2018-12-10", "inspection_date": "2018-11-30", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_u_value": 1.27, "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.64, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 15.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_u_value": 1.27, "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.06, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 803, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 351, "currency": "GBP"}, "hot_water_cost_current": {"value": 250, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 245, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 60}], "co2_emissions_potential": 3.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 264, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 190, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 186, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2665, "impact_of_cavity_insulation": -2607, "space_heating_existing_dwelling": 8475}, "energy_consumption_current": 555, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 302, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 94, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100050181448, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN18 6ER", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARTON-UPON-HUMBER", "built_form": 3, "created_at": "2018-10-22 12:39:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "18, Fairfield Drive", "assessment_type": "RdSAP", "completion_date": "2018-10-22", "inspection_date": "2018-10-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.47, "quantity": "square metres"}, "party_wall_length": {"value": 8.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 43.47, "quantity": "square metres"}, "party_wall_length": {"value": 8.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 538, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2165, "space_heating_existing_dwelling": 8476}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 114, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050563875, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO10 3LL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 4, "created_at": "2018-09-27 10:34:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16637}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "4, Lamel Street", "assessment_type": "RdSAP", "completion_date": "2018-09-27", "inspection_date": "2018-09-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 18.36, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.43, "quantity": "square metres"}, "party_wall_length": {"value": 15.19, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 23.94, "quantity": "square metres"}, "party_wall_length": {"value": 14.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.66, "quantity": "square metres"}, "party_wall_length": {"value": 3.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 719, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 211, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1922, "impact_of_loft_insulation": -585, "impact_of_solid_wall_insulation": -910, "space_heating_existing_dwelling": 13789}, "energy_consumption_current": 312, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 108, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021551428, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 92% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TW3 1TA", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "HOUNSLOW", "built_form": 4, "created_at": "2018-12-24 09:44:43.000000", "door_count": 3, "glazed_area": 3, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 24 Madison Heights", "address_line_2": "17-27, High Street", "assessment_type": "RdSAP", "completion_date": "2018-12-24", "inspection_date": "2018-12-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 6, "heat_loss_corridor": 2, "unheated_corridor_length": 10.28}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 25.2888, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 60.34, "quantity": "square metres"}, "party_wall_length": {"value": 11.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 239, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 142, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 136, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1726, "space_heating_existing_dwelling": 2467}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 170, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 42146675, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH45 7QG", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WALLASEY", "built_form": 3, "created_at": "2018-05-24 13:56:44.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 19 Nicola Court", "address_line_2": "Penkett Road", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.13, "quantity": "metres"}}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.8268, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 60.01, "quantity": "square metres"}, "party_wall_length": {"value": 3.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.56, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1103, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 30, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 572, "currency": "GBP"}, "hot_water_cost_current": {"value": 313, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 636, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 40}], "co2_emissions_potential": 4.7, "energy_rating_potential": 62, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 804, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 689, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1940, "impact_of_solid_wall_insulation": -375, "space_heating_existing_dwelling": 6842}, "energy_consumption_current": 463, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 463, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 40, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10001149720, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BA2 2TS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BATH", "built_form": 2, "created_at": "2018-03-23 15:02:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10071}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Orchid Drive", "assessment_type": "RdSAP", "completion_date": "2018-03-23", "inspection_date": "2018-03-23", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-03-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.84, "quantity": "square metres"}, "party_wall_length": {"value": 6.29, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 23.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 52.84, "quantity": "square metres"}, "party_wall_length": {"value": 6.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 362, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 366, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2445, "space_heating_existing_dwelling": 5559}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 65, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 263354, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS8 2DJ", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-02-23 13:41:26.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "62 Alma Road", "address_line_3": "Clifton", "assessment_type": "RdSAP", "completion_date": "2018-02-23", "inspection_date": "2018-02-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.5, "quantity": "metres"}}, "total_floor_area": 22, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-02-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 22.49, "quantity": "square metres"}, "party_wall_length": {"value": 4.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 467, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 21, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 141, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 25, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 5, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 834, "impact_of_solid_wall_insulation": -1215, "space_heating_existing_dwelling": 2900}, "energy_consumption_current": 527, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 251, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 89, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10024134892, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN18 4FE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CRANBROOK", "built_form": 4, "created_at": "2018-10-25 14:40:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Gunther Close", "address_line_2": "Hawkhurst", "assessment_type": "RdSAP", "completion_date": "2018-10-25", "inspection_date": "2018-07-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.8, "quantity": "square metres"}, "party_wall_length": {"value": 17, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.8, "quantity": "square metres"}, "party_wall_length": {"value": 17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 333, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 335, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2087, "space_heating_existing_dwelling": 3711}, "energy_consumption_current": 143, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 50, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100062154842, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly secondary glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GU16 6ET", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBERLEY", "built_form": 2, "created_at": "2018-11-06 15:26:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10267}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "110 Mytchett Road", "assessment_type": "RdSAP", "completion_date": "2018-11-06", "inspection_date": "2018-11-06", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 5.15}, "total_floor_area": 37, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.4715, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.81, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.99, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.81, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.78, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 395, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 279, "currency": "GBP"}, "hot_water_cost_current": {"value": 69, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.5, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1501, "impact_of_loft_insulation": -154, "impact_of_cavity_insulation": -1326, "impact_of_solid_wall_insulation": -424, "space_heating_existing_dwelling": 6424}, "energy_consumption_current": 329, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "3.08r07", "energy_consumption_potential": 226, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200004817359, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BH20 6JU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WAREHAM", "built_form": 2, "created_at": "2018-10-27 18:38:32.000000", "door_count": 3, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16394}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Sewell Road", "address_line_2": "Bovington", "assessment_type": "RdSAP", "completion_date": "2018-10-27", "inspection_date": "2018-10-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.58, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 53.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.81, "quantity": "square metres"}, "party_wall_length": {"value": 4.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 592, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 455, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 336, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2948, "impact_of_cavity_insulation": -2560, "space_heating_existing_dwelling": 10974}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 77, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100050354973, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD23 5HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SKIPTON", "built_form": 3, "created_at": "2018-12-21 18:02:16.000000", "door_count": 2, "glazed_area": 2, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Piece Fields", "address_line_2": "Threshfield", "assessment_type": "RdSAP", "completion_date": "2018-12-21", "inspection_date": "2018-12-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-12-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.96, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 42.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 536, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2074, "space_heating_existing_dwelling": 9687}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100050964666, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S5 7SY", "hot_water": {"description": "No system present: electric immersion assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2018-12-20 16:39:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 999, "water_heating_fuel": 0, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 601, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "155, Emerson Crescent", "assessment_type": "RdSAP", "completion_date": "2018-12-20", "inspection_date": "2018-12-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-12-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.24, "quantity": "square metres"}, "party_wall_length": {"value": 10.79, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.23, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 374, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 234, "currency": "GBP"}, "hot_water_cost_current": {"value": 494, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 501, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 512, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 459, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 447, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2985, "space_heating_existing_dwelling": 3284}, "energy_consumption_current": 478, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 187, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 82, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100032039036, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LE11 1JY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LOUGHBOROUGH", "built_form": 3, "created_at": "2018-04-28 08:38:56.000000", "door_count": 4, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16903}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Meadow Lane", "assessment_type": "RdSAP", "completion_date": "2018-04-28", "inspection_date": "2018-04-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 33.6, "quantity": "square metres"}, "party_wall_length": {"value": 0.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 33.6, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 17.2, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 20.4, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 502, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 507, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1831, "impact_of_loft_insulation": -608, "space_heating_existing_dwelling": 8690}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100060439593, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO9 4DX", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HAVANT", "built_form": 2, "created_at": "2018-08-29 21:53:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "40, Shawford Grove", "assessment_type": "RdSAP", "completion_date": "2018-08-29", "inspection_date": "2018-08-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-08-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.94, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 33.99, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 838, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 485, "currency": "GBP"}, "hot_water_cost_current": {"value": 243, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 333, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 353, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 428, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 393, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2034, "space_heating_existing_dwelling": 5738}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 212, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 2465170706, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LE3 9EB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2018-01-31 10:27:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "194 Roberta Court", "address_line_2": "Groby Road", "assessment_type": "RdSAP", "completion_date": "2018-01-31", "inspection_date": "2018-01-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-01-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 1.7, "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.12, "quantity": "square metres"}, "party_wall_length": {"value": 9.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 255, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 258, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1593, "space_heating_existing_dwelling": 3181}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 183, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100100855103, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LL11 6RE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WREXHAM", "built_form": 2, "created_at": "2018-10-28 22:45:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Cynlas", "address_line_2": "Southsea", "assessment_type": "RdSAP", "completion_date": "2018-10-28", "inspection_date": "2018-10-26", "extensions_count": 2, "measurement_type": 2, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 10.8, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 744, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 600, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2775, "impact_of_loft_insulation": -227, "impact_of_cavity_insulation": -1775, "space_heating_existing_dwelling": 10647}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 179, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100060809987, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT2 9HE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CANTERBURY", "built_form": 1, "created_at": "2018-10-30 20:11:31", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31c, Chapel Lane", "address_line_2": "Blean", "assessment_type": "RdSAP", "completion_date": "2018-10-30", "inspection_date": "2018-10-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 152, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-10-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 68.84, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 68.84, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.86, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 812, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 686, "currency": "GBP"}, "hot_water_cost_current": {"value": 163, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 226, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2882, "impact_of_loft_insulation": -361, "space_heating_existing_dwelling": 12658}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 102, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 217109252, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW7 4XN", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 5, "created_at": "2018-09-04 19:30:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2706, "main_heating_category": 8, "main_heating_fraction": 1, "sap_main_heating_code": 422, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric underfloor heating", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1005 Point West", "address_line_2": "116, Cromwell Road", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 10, "heat_loss_corridor": 2, "unheated_corridor_length": 8.42}, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.5344, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 85.21, "quantity": "square metres"}, "party_wall_length": {"value": 10.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 159, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 83, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 159, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 173, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2151, "space_heating_existing_dwelling": 1518}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 147, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "B", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100011399592, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M6 6HP", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SALFORD", "built_form": 4, "created_at": "2018-07-22 14:54:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "78, Auckland Drive", "assessment_type": "RdSAP", "completion_date": "2018-07-22", "inspection_date": "2018-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.6, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.6, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 405, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 386, "currency": "GBP"}, "hot_water_cost_current": {"value": 186, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3479, "space_heating_existing_dwelling": 5835}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 97, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10007368437, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 24% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "HR4 7QT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HEREFORD", "built_form": 1, "created_at": "2018-06-01 14:36:44", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8641}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "1 South Cottages", "address_line_2": "Jasmine Lane", "address_line_3": "Burghill", "assessment_type": "RdSAP", "completion_date": "2018-06-01", "inspection_date": "2018-05-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 24, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 844, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 668, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 14, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 190, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2708, "space_heating_existing_dwelling": 13705}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 141, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10093038970, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG2 7PL", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "ILFORD", "built_form": 1, "created_at": "2018-05-22 11:27:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "31 Oaks Lane", "assessment_type": "RdSAP", "completion_date": "2018-05-22", "inspection_date": "2018-05-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 37, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-05-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "total_floor_area": {"value": 36.73, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 155, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 118, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 88, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1463, "space_heating_existing_dwelling": 1660}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 232, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10009157931, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG3 6BR", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-05-22 09:51:14.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 7 Jenner House", "address_line_2": "Ockbrook Drive", "assessment_type": "RdSAP", "completion_date": "2018-05-22", "inspection_date": "2018-05-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.09, "quantity": "metres"}}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 390, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.202, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 68.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 214, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 134, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 142, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 136, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1812, "space_heating_existing_dwelling": 1462}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 152, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100050461697, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO14 0NQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FILEY", "built_form": 1, "created_at": "2018-03-30 12:50:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16399}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "32, Percy Road", "address_line_2": "Hunmanby", "assessment_type": "RdSAP", "completion_date": "2018-03-30", "inspection_date": "2018-03-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-03-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 58.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 849, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 786, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2813, "space_heating_existing_dwelling": 14703}, "energy_consumption_current": 244, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 165, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100061910441, "roofs": [{"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN21 2EW", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "EASTBOURNE", "built_form": 2, "created_at": "2018-11-08 10:05:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 16 Arundel Keep", "address_line_2": "14, Arundel Road", "assessment_type": "RdSAP", "completion_date": "2018-11-08", "inspection_date": "2018-11-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 3.03}, "total_floor_area": 32, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-11-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": "NR", "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.1508, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 260, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 31.99, "quantity": "square metres"}, "party_wall_length": {"value": 6.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.58, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 510, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 170, "currency": "GBP"}, "hot_water_cost_current": {"value": 212, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 83, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 221, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 63}], "co2_emissions_potential": 1.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 229, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 176, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 126, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1492, "impact_of_solid_wall_insulation": -217, "space_heating_existing_dwelling": 5348}, "energy_consumption_current": 672, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 348, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 4, "multiple_glazed_proportion_nr": "NR", "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 114, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100030959877, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DN41 8HU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "GRIMSBY", "built_form": 2, "created_at": "2018-09-12 10:40:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Cissplatt Lane", "address_line_2": "Keelby", "assessment_type": "RdSAP", "completion_date": "2018-09-12", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.28, "quantity": "square metres"}, "party_wall_length": {"value": 8.04, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 47.28, "quantity": "square metres"}, "party_wall_length": {"value": 8.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 718, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 534, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 162, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2815, "space_heating_existing_dwelling": 8511}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 123, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 1775027908, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO4 9LX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHSEA", "built_form": 4, "created_at": "2018-07-25 13:49:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18037}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "39, Ferry Road", "assessment_type": "RdSAP", "completion_date": "2018-07-25", "inspection_date": "2018-07-13", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 39.29, "quantity": "square metres"}, "party_wall_length": {"value": 16.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 39.29, "quantity": "square metres"}, "party_wall_length": {"value": 16.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 3.15, "quantity": "square metres"}, "party_wall_length": {"value": 1.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 390, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 390, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.5, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 130, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2819, "space_heating_existing_dwelling": 6330}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 174, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 1775059352, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PO5 4DR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHSEA", "built_form": 2, "created_at": "2018-07-23 19:54:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17644}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "39, Norfolk Street", "assessment_type": "RdSAP", "completion_date": "2018-07-23", "inspection_date": "2018-07-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.2, "quantity": "metres"}}, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 75.46, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 343, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 300, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1802, "impact_of_loft_insulation": -436, "impact_of_cavity_insulation": -182, "space_heating_existing_dwelling": 4744}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 129, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100050575517, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "YO23 1DU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 2, "created_at": "2018-04-10 06:19:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Nunthorpe Crescent", "assessment_type": "RdSAP", "completion_date": "2018-04-10", "inspection_date": "2018-04-07", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 139, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 287, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 16.26, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.81, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 43.16, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 289, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.31, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 6.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 288, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1170, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 135, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1016, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 4.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2311, "impact_of_loft_insulation": -2446, "impact_of_cavity_insulation": -1947, "space_heating_existing_dwelling": 18523}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 178, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090555824, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM3 6JE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHELMSFORD", "built_form": 1, "created_at": "2018-04-05 18:12:31.000000", "door_count": 3, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8893}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "33, St. Stephens Road", "address_line_2": "Cold Norton", "assessment_type": "RdSAP", "completion_date": "2018-04-05", "inspection_date": "2018-04-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-04-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 656, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 392, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3459, "impact_of_loft_insulation": -586, "impact_of_solid_wall_insulation": -1855, "space_heating_existing_dwelling": 14142}, "energy_consumption_current": 244, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 103, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100091448240, "roofs": [{"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 10% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CM5 0QS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "ONGAR", "built_form": 1, "created_at": "2018-05-24 21:48:42.000000", "door_count": 4, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 27, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 17563}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Keepers Cottage", "address_line_2": "Wood Lane", "address_line_3": "Willingale", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 151, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 44.89, "insulation": 2, "roof_room_connected": "Y", "construction_age_band": "A", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.71, "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.04, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.69, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 27.88, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "H"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.15, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.08, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 5.18, "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1683, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 29, "lighting_cost_current": {"value": 177, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1147, "currency": "GBP"}, "hot_water_cost_current": {"value": 304, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": 180, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "2,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 65}, {"sequence": 8, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.9, "energy_rating_potential": 60, "lighting_cost_potential": {"value": 93, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4040, "impact_of_loft_insulation": -406, "impact_of_solid_wall_insulation": -1557, "space_heating_existing_dwelling": 22004}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 111, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 40, "current_energy_efficiency_band": "F", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100120861589, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [10]}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX11 7PT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "DIDCOT", "built_form": 5, "created_at": "2018-04-02 12:57:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "27, Venners Water", "assessment_type": "RdSAP", "completion_date": "2018-04-02", "inspection_date": "2018-03-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.5, "quantity": "metres"}}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-04-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.585, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60, "quantity": "square metres"}, "party_wall_length": {"value": 15.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 302, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 65}], "co2_emissions_potential": 2.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1922, "space_heating_existing_dwelling": 3569}, "energy_consumption_current": 296, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 252, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100050898801, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S25 4GZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 1, "created_at": "2018-11-05 14:53:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17038}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Winberry Avenue", "address_line_2": "North Anston", "assessment_type": "RdSAP", "completion_date": "2018-11-05", "inspection_date": "2018-11-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 125, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-11-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.89, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 30, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 55.89, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 25.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.98, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.22, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 974, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 855, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}], "co2_emissions_potential": 3.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1992, "space_heating_existing_dwelling": 15325}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 158, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100031179943, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NN7 2NR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 2, "created_at": "2018-09-19 07:39:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, The Leys", "address_line_2": "Roade", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 33.11, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "150mm"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.11, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 33.11, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1036, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 556, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 192, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2217, "impact_of_loft_insulation": -300, "impact_of_cavity_insulation": -774, "impact_of_solid_wall_insulation": -3820, "space_heating_existing_dwelling": 21023}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 104, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100031725571, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "ST5 2BH", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NEWCASTLE", "built_form": 2, "created_at": "2018-02-02 16:51:28.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 605, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "49, Florence Street", "assessment_type": "RdSAP", "completion_date": "2018-02-02", "inspection_date": "2018-02-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 41, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-02-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.3, "quantity": "square metres"}, "party_wall_length": {"value": 10.33, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 734, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 37, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 242, "currency": "GBP"}, "hot_water_cost_current": {"value": 279, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 241, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 333, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 366, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 352, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 83}, {"sequence": 3, "typical_saving": {"value": 316, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1728, "impact_of_solid_wall_insulation": -2263, "space_heating_existing_dwelling": 6083}, "energy_consumption_current": 605, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 184, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100040546361, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "TQ1 2NQ", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "TORQUAY", "built_form": 5, "created_at": "2018-02-13 14:12:30.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6 West Lodge", "address_line_2": "Higher Erith Road", "assessment_type": "RdSAP", "completion_date": "2018-02-13", "inspection_date": "2018-02-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 640, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.56, "quantity": "square metres"}, "party_wall_length": {"value": 20.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 628, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 275, "currency": "GBP"}, "hot_water_cost_current": {"value": 209, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 237, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.4, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 206, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 191, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 209, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1177, "impact_of_solid_wall_insulation": -2684, "space_heating_existing_dwelling": 7003}, "energy_consumption_current": 421, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 227, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100061358103, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT19 8ST", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "EPSOM", "built_form": 4, "created_at": "2018-02-16 18:54:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "134, Horton Hill", "assessment_type": "RdSAP", "completion_date": "2018-02-16", "inspection_date": "2018-02-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.148, "quantity": "square metres"}, "party_wall_length": {"value": 13.34, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 30.148, "quantity": "square metres"}, "party_wall_length": {"value": 13.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.04, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 473, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 374, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 10, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 5, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2174, "space_heating_existing_dwelling": 7426}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "2.0.x", "energy_consumption_potential": 92, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10032958267, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ13 0LN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWTON ABBOT", "built_form": 3, "created_at": "2018-07-23 08:38:55.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "29, Haldon View", "address_line_2": "Chudleigh", "assessment_type": "RdSAP", "completion_date": "2018-07-23", "inspection_date": "2018-07-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.51, "quantity": "square metres"}, "party_wall_length": {"value": 6.63, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.58, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 404, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 358, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1630, "impact_of_loft_insulation": -267, "space_heating_existing_dwelling": 6411}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 90, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100021236956, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N15 3PA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-07-24 20:07:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17857}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Second Floor Flat", "address_line_2": "311 West Green Road", "assessment_type": "RdSAP", "completion_date": "2018-07-24", "inspection_date": "2018-07-24", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 97, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": {"value": 35.29, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 35.29, "quantity": "square metres"}, "party_wall_length": {"value": 14.798, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 6.655, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 13.15, "quantity": "square metres"}, "party_wall_length": {"value": 4.558, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 7.443, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 13.15, "quantity": "square metres"}, "party_wall_length": {"value": 4.558, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.443, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 989, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 699, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 88, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}], "co2_emissions_potential": 4.1, "energy_rating_potential": 63, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "impact_of_solid_wall_insulation": -2246, "space_heating_existing_dwelling": 18508}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 237, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 47027112, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE12 6SZ", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 2, "created_at": "2018-04-10 07:36:18.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1554}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "28, Crumstone Court", "address_line_2": "Garth Twentyone", "assessment_type": "RdSAP", "completion_date": "2018-04-10", "inspection_date": "2018-04-09", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 104, "transaction_type": 2, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.4, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.56, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 49.14, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 3.64, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1314, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 733, "currency": "GBP"}, "hot_water_cost_current": {"value": 276, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 4, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 47}, {"sequence": 6, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 47}, {"sequence": 7, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 8, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 9, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 10, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 11, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 387, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3897, "impact_of_cavity_insulation": -1823, "impact_of_solid_wall_insulation": -545, "space_heating_existing_dwelling": 15249}, "energy_consumption_current": 456, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 169, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10008059156, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE2 9SE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 1, "created_at": "2018-05-31 15:38:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10261}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Bailey Way", "assessment_type": "RdSAP", "completion_date": "2018-05-31", "inspection_date": "2018-05-31", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 527, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 537, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 85, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2686, "space_heating_existing_dwelling": 7384}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 95, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200000801316, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL7 1PG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARLOW", "built_form": 4, "created_at": "2018-06-03 13:37:38.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17558}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "72a, Dedmere Road", "assessment_type": "RdSAP", "completion_date": "2018-06-03", "inspection_date": "2018-06-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 14.9, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "I"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.82, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 32.82, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 369, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 369, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1960, "impact_of_loft_insulation": -86, "space_heating_existing_dwelling": 5725}, "energy_consumption_current": 150, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 67, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 10013945266, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL20 7PE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "TEWKESBURY", "built_form": 1, "created_at": "2018-09-13 12:37:01.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8759}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Woodlands", "address_line_2": "Overbury", "assessment_type": "RdSAP", "completion_date": "2018-09-13", "inspection_date": "2018-08-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 244, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-09-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 21.9, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 103.98, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 42.68, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 103.98, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 39.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.67, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2352, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 18, "energy_rating_average": 60, "energy_rating_current": 29, "lighting_cost_current": {"value": 146, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1554, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 33, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 531, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 35}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 36}, {"sequence": 4, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 40}, {"sequence": 6, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 42}, {"sequence": 7, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 45}], "co2_emissions_potential": 11, "energy_rating_potential": 55, "lighting_cost_potential": {"value": 148, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3026, "impact_of_loft_insulation": -6184, "impact_of_solid_wall_insulation": -10490, "space_heating_existing_dwelling": 43073}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 33, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 170, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 45, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100050532520, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO24 2RZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 2, "created_at": "2018-11-09 15:31:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17503}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "32, Arundel Grove", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-11-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 532, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 436, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 48, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1642, "impact_of_loft_insulation": -558, "space_heating_existing_dwelling": 7077}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100100802604, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 8% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NP4 0DG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTYPOOL", "built_form": 1, "created_at": "2018-11-08 13:57:25.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 16453}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "12, Oak Tree Close", "address_line_2": "New Inn", "assessment_type": "RdSAP", "completion_date": "2018-11-08", "inspection_date": "2018-11-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-11-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.87, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 56.78, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 723, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 140, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 657, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2839, "impact_of_loft_insulation": -387, "space_heating_existing_dwelling": 10914}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 120, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10024180863, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BB10 2RB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURNLEY", "built_form": 1, "created_at": "2018-02-19 17:19:51.000000", "door_count": 3, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 3, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Reedley Farm Close", "assessment_type": "RdSAP", "completion_date": "2018-02-19", "inspection_date": "2018-02-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 220, "transaction_type": 11, "conservatory_type": 3, "heated_room_count": 8, "registration_date": "2018-02-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 85, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 25.13, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 15.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 967, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 967, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 78}], "co2_emissions_potential": 4.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 106, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2358, "space_heating_existing_dwelling": 17016}, "energy_consumption_current": 145, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 24, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 24} +{"uprn": 38139526, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L6 4EA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2018-02-20 16:59:58.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "1, Simms Road", "assessment_type": "RdSAP", "completion_date": "2018-02-20", "inspection_date": "2018-02-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.22, "quantity": "square metres"}, "party_wall_length": {"value": 7.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.01, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 323, "currency": "GBP"}, "insulated_door_count": 1, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "insulated_door_u_value": 0.91, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.4, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1743, "impact_of_loft_insulation": -457, "space_heating_existing_dwelling": 4685}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 46, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040940286, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TA1 2XD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TAUNTON", "built_form": 2, "created_at": "2018-07-30 13:00:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18119}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "1a, Russett Road", "assessment_type": "RdSAP", "completion_date": "2018-07-30", "inspection_date": "2018-07-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 7.2}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.344, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 309, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 62, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1399, "impact_of_cavity_insulation": -258, "space_heating_existing_dwelling": 4452}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 169, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200004791588, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 91% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH13 9GL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORSHAM", "built_form": 2, "created_at": "2018-07-29 15:43:44.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5928}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "17, Warren Drive", "address_line_2": "Southwater", "assessment_type": "RdSAP", "completion_date": "2018-07-29", "inspection_date": "2018-07-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.34, "quantity": "square metres"}, "party_wall_length": {"value": 8.06, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 40.36, "quantity": "square metres"}, "party_wall_length": {"value": 8.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 91, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 557, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 448, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2680, "impact_of_loft_insulation": -448, "space_heating_existing_dwelling": 7934}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 101, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100080022771, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly multiple glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "MK41 9SX", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BEDFORD", "built_form": 4, "created_at": "2018-06-07 16:53:47.000000", "door_count": 1, "glazed_area": 4, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1842}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "sap_windows": [{"pvc_frame": "false", "orientation": 7, "window_area": {"value": 9.42, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 3, "window_area": {"value": 6.87, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"orientation": 7, "window_area": {"value": 1.85, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"orientation": 3, "window_area": {"value": 0.6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Kimble Drive", "assessment_type": "RdSAP", "completion_date": "2018-06-07", "inspection_date": "2018-06-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.19, "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.83, "quantity": "square metres"}, "party_wall_length": {"value": 13.82, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 38.83, "quantity": "square metres"}, "party_wall_length": {"value": 13.82, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 862, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 590, "currency": "GBP"}, "hot_water_cost_current": {"value": 203, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 78, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 5, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 6, "typical_saving": {"value": 167, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 224, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3467, "impact_of_loft_insulation": -3595, "impact_of_cavity_insulation": -791, "space_heating_existing_dwelling": 13390}, "energy_consumption_current": 402, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 87, "calculation_software_version": "2.0.x", "energy_consumption_potential": 157, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 3455085553, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST4 2ET", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2018-09-10 15:44:36.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "94, Seaford Street", "assessment_type": "RdSAP", "completion_date": "2018-09-10", "inspection_date": "2018-08-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 146, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-09-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 26.06, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.69, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 43.13, "quantity": "square metres"}, "party_wall_length": {"value": 11.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.92, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.83, "quantity": "metres"}, "total_floor_area": {"value": 43.13, "quantity": "square metres"}, "party_wall_length": {"value": 11.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.84, "quantity": "square metres"}, "party_wall_length": {"value": 3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.86, "quantity": "square metres"}, "party_wall_length": {"value": 8.17, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1373, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1115, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 62}], "co2_emissions_potential": 5.3, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2316, "impact_of_loft_insulation": -1733, "impact_of_solid_wall_insulation": -4685, "space_heating_existing_dwelling": 26826}, "energy_consumption_current": 306, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 205, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100060743199, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO19 8SL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-11-13 23:16:30.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1369}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "25, Willow Tree Walk", "assessment_type": "RdSAP", "completion_date": "2018-11-13", "inspection_date": "2018-11-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.47, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 728, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 406, "currency": "GBP"}, "hot_water_cost_current": {"value": 188, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 130, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 7, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 8, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 9, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 90}, {"sequence": 3, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2914, "impact_of_cavity_insulation": -2032, "space_heating_existing_dwelling": 9775}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 97, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10090335147, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX34 8PF", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ILFRACOMBE", "built_form": 4, "created_at": "2018-02-26 19:15:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "23G Green Parks Holidays Ilfracombe", "address_line_2": "Marlborough Road", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.53, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 294, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 275, "currency": "GBP"}, "hot_water_cost_current": {"value": 160, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a3500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.5, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 160, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 993, "space_heating_existing_dwelling": 1821}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 202, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100061175904, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 13% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "TN10 4EY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TONBRIDGE", "built_form": 1, "created_at": "2018-04-20 15:21:38.000000", "door_count": 3, "glazed_area": 2, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17568}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "42, Old Hadlow Road", "assessment_type": "RdSAP", "completion_date": "2018-04-20", "inspection_date": "2018-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 142, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 35.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 70.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 35.08, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 855, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 163, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 677, "currency": "GBP"}, "hot_water_cost_current": {"value": 155, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": 100, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 87, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3306, "impact_of_loft_insulation": -1505, "space_heating_existing_dwelling": 15544}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 106, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 23, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010995341, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "M45 7QN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 1, "created_at": "2018-01-31 08:09:16.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17825}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "48, Hillingdon Road", "address_line_2": "Whitefield", "assessment_type": "RdSAP", "completion_date": "2018-01-31", "inspection_date": "2018-01-30", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 171, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-01-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.26, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 66.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 3.96, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.77, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1123, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 831, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 181, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 258, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2858, "impact_of_loft_insulation": -209, "impact_of_cavity_insulation": -3746, "impact_of_solid_wall_insulation": -1036, "space_heating_existing_dwelling": 22706}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 127, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 200001144130, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LN12 1HA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MABLETHORPE", "built_form": 2, "created_at": "2018-11-23 15:11:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Station Road", "assessment_type": "RdSAP", "completion_date": "2018-11-23", "inspection_date": "2018-11-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 459, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 345, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1836, "space_heating_existing_dwelling": 6465}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 71, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100081047342, "roofs": [{"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL6 2NN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 1, "created_at": "2018-11-24 20:13:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15451}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Old Beams", "address_line_2": "Forest Green Road", "address_line_3": "Holyport", "assessment_type": "RdSAP", "completion_date": "2018-11-24", "inspection_date": "2018-11-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 124, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-11-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 45.21, "quantity": "square metres"}, "insulation": 6, "roof_room_connected": "N", "construction_age_band": "C", "roof_insulation_thickness": "100mm"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.06, "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.66, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.51, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.98, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1241, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 727, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 85, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}, {"sequence": 8, "typical_saving": {"value": 618, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 95, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 95, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2954, "impact_of_loft_insulation": -1449, "impact_of_cavity_insulation": -408, "impact_of_solid_wall_insulation": -1480, "space_heating_existing_dwelling": 20740}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 30, "calculation_software_version": "2.0.x", "energy_consumption_potential": 41, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 33, "current_energy_efficiency_band": "E", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 33} +{"uprn": 42048133, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CH49 3NG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIRRAL", "built_form": 3, "created_at": "2018-10-04 16:39:18.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "108, Greasby Road", "address_line_2": "Greasby", "assessment_type": "RdSAP", "completion_date": "2018-10-04", "inspection_date": "2018-10-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.12, "quantity": "square metres"}, "party_wall_length": {"value": 7.11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 22.86, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.38, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 528, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 331, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 47, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1646, "impact_of_cavity_insulation": -358, "impact_of_solid_wall_insulation": -2987, "space_heating_existing_dwelling": 8736}, "energy_consumption_current": 322, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 75, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200003776236, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF72 8SG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTYCLUN", "built_form": 1, "created_at": "2018-07-04 08:33:03.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8575}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Georgian Way", "address_line_2": "Miskin", "assessment_type": "RdSAP", "completion_date": "2018-07-04", "inspection_date": "2018-07-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-07-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.71, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 41.71, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 23.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.88, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 529, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 466, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2992, "impact_of_loft_insulation": -232, "space_heating_existing_dwelling": 8175}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 94, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100031392991, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG18 2PS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANSFIELD", "built_form": 2, "created_at": "2018-04-25 09:26:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9571}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "11, Bolsover Street", "assessment_type": "RdSAP", "completion_date": "2018-04-25", "inspection_date": "2018-04-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 11.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.54, "quantity": "metres"}, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 11.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 779, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 436, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 10, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2127, "impact_of_solid_wall_insulation": -5137, "space_heating_existing_dwelling": 13243}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 102, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 83028255, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HD4 7JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 2, "created_at": "2018-04-24 11:26:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16632}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "10, Marten Drive", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.7028, "quantity": "square metres"}, "party_wall_length": {"value": 9.07, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 470, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 395, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1874, "space_heating_existing_dwelling": 7178}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 12069821, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W13 9TF", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-03-05 21:55:10.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 604, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Belsize Avenue", "assessment_type": "RdSAP", "completion_date": "2018-03-05", "inspection_date": "2018-03-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-03-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.28, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 34.08, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.36, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 664, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 370, "currency": "GBP"}, "hot_water_cost_current": {"value": 249, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 70, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 7, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 8, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 10, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 138, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3475, "impact_of_solid_wall_insulation": -1670, "space_heating_existing_dwelling": 8422}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 75, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 63155832, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF2 8WA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WAKEFIELD", "built_form": 4, "created_at": "2018-01-05 09:38:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "21, Brackendale Road", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.22, "quantity": "square metres"}, "party_wall_length": {"value": 11.71, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 27.27, "quantity": "square metres"}, "party_wall_length": {"value": 12.71, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.49, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 27.27, "quantity": "square metres"}, "party_wall_length": {"value": 12.71, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.53, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 13.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.39, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 13.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 790, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 575, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 89, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 245, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2745, "impact_of_loft_insulation": -191, "space_heating_existing_dwelling": 9992}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 97, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 77177975, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "M11 1AZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 2, "created_at": "2018-01-05 12:25:06.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "24, High Legh Road", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 4.2}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.626, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 39.74, "quantity": "square metres"}, "party_wall_length": {"value": 4.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.42, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 260, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 264, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1832, "impact_of_solid_wall_insulation": -312, "space_heating_existing_dwelling": 3289}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 206, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100040776453, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BH1 3TA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BOURNEMOUTH", "built_form": 6, "created_at": "2018-11-28 21:20:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 15 Grosvenor Court", "address_line_2": "Vale Road", "assessment_type": "RdSAP", "completion_date": "2018-11-28", "inspection_date": "2018-11-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.44, "quantity": "metres"}}, "total_floor_area": 46, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.656, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45.59, "quantity": "square metres"}, "party_wall_length": {"value": 7.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1015, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 689, "currency": "GBP"}, "hot_water_cost_current": {"value": 246, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 17}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 17}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 17}, {"sequence": 4, "typical_saving": {"value": 394, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 27}], "co2_emissions_potential": 5.3, "energy_rating_potential": 50, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 567, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 415, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 57}], "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1775, "impact_of_loft_insulation": -4988, "impact_of_solid_wall_insulation": -335, "space_heating_existing_dwelling": 11380}, "energy_consumption_current": 907, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 689, "environmental_impact_current": 16, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "F", "environmental_impact_potential": 27, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 153, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 452037891, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TF2 8LE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TELFORD", "built_form": 4, "created_at": "2018-11-26 17:07:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 8788}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "7, Donnington Way", "address_line_2": "Donnington", "assessment_type": "RdSAP", "completion_date": "2018-11-26", "inspection_date": "2018-11-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.87, "quantity": "square metres"}, "party_wall_length": {"value": 10.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33.12, "quantity": "square metres"}, "party_wall_length": {"value": 10.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 463, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 413, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2546, "impact_of_loft_insulation": -227, "space_heating_existing_dwelling": 6426}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 107, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021592770, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "UB2 5RS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHALL", "built_form": 4, "created_at": "2018-10-08 19:06:59.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15426}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, The Glen", "assessment_type": "RdSAP", "completion_date": "2018-10-08", "inspection_date": "2018-10-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 167, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 35.05, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "L", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 49.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.32, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 674, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 643, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2986, "impact_of_loft_insulation": -1399, "impact_of_cavity_insulation": -838, "space_heating_existing_dwelling": 12769}, "energy_consumption_current": 142, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 39, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 39} +{"uprn": 100031787871, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST17 9TU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 2, "created_at": "2018-04-19 17:03:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10126}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Wordsworth Avenue", "assessment_type": "RdSAP", "completion_date": "2018-04-19", "inspection_date": "2018-04-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.05, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 39.05, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 772, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 701, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.9, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2092, "space_heating_existing_dwelling": 12121}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 91, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 207, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100121333496, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SP2 8DT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SALISBURY", "built_form": 1, "created_at": "2018-04-27 12:30:27.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 0, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "34, Bouverie Avenue", "assessment_type": "RdSAP", "completion_date": "2018-04-27", "inspection_date": "2018-04-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.44, "quantity": "metres"}}, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.484, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 931, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 347, "currency": "GBP"}, "hot_water_cost_current": {"value": 283, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 205, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 160, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 228, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 57}], "co2_emissions_potential": 3.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 281, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 92}, {"sequence": 3, "typical_saving": {"value": 265, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 78}], "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2013, "impact_of_cavity_insulation": -2316, "impact_of_solid_wall_insulation": -668, "space_heating_existing_dwelling": 10430}, "energy_consumption_current": 589, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 298, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 100, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100060440853, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PO9 4DJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HAVANT", "built_form": 2, "created_at": "2018-05-10 13:48:31.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16739}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Sunwood Road", "assessment_type": "RdSAP", "completion_date": "2018-05-10", "inspection_date": "2018-05-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-05-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 279, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.18, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 51.18, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 631, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 444, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2201, "impact_of_loft_insulation": -675, "impact_of_cavity_insulation": -2862, "space_heating_existing_dwelling": 11610}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 74, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 646715, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS15 9RA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 4, "created_at": "2018-06-25 16:58:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "51, Springly Court", "address_line_2": "Grimsbury Road", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.79, "quantity": "metres"}}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.54, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 38.3, "quantity": "square metres"}, "party_wall_length": {"value": 11.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 275, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 227, "currency": "GBP"}, "hot_water_cost_current": {"value": 213, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.0, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 213, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1551, "impact_of_loft_insulation": -216, "space_heating_existing_dwelling": 2567}, "energy_consumption_current": 346, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 309, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100021292023, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA1 4DP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 2, "created_at": "2018-03-29 11:19:36.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16930}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "21a, Vaughan Road", "assessment_type": "RdSAP", "completion_date": "2018-03-29", "inspection_date": "2018-03-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.629, "quantity": "metres"}, "total_floor_area": {"value": 87.64, "quantity": "square metres"}, "party_wall_length": {"value": 15.497, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 474, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 302, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2170, "impact_of_solid_wall_insulation": -3855, "space_heating_existing_dwelling": 8074}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 121, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100100654517, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NP19 7FE", "hot_water": {"description": {"value": "No system present: electric immersion assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NEWPORT", "built_form": 4, "created_at": "2018-10-15 14:12:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 999, "water_heating_fuel": 0, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "No system present: electric heaters assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Canon Street", "assessment_type": "RdSAP", "completion_date": "2018-10-15", "inspection_date": "2018-10-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 0, "registration_date": "2018-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.3, "quantity": "square metres"}, "party_wall_length": {"value": 13.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 30.3, "quantity": "square metres"}, "party_wall_length": {"value": 13.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.64, "quantity": "square metres"}, "party_wall_length": {"value": 3.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1615, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 14, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 290, "currency": "GBP"}, "hot_water_cost_current": {"value": 560, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 16, "environmental_impact_rating": 28}, {"sequence": 2, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 21, "environmental_impact_rating": 33}, {"sequence": 3, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 24, "environmental_impact_rating": 34}, {"sequence": 4, "typical_saving": {"value": 226, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 40}, {"sequence": 5, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 41}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 43}, {"sequence": 7, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 43}, {"sequence": 8, "typical_saving": {"value": 1036, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 9, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 10, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 11, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 25, "environmental_impact_rating": 35}, {"sequence": 2, "typical_saving": {"value": 1006, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 903, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 1032, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3381, "impact_of_loft_insulation": -411, "impact_of_cavity_insulation": -517, "impact_of_solid_wall_insulation": -1314, "space_heating_existing_dwelling": 9761}, "energy_consumption_current": 562, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 42, "environmental_impact_current": 27, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "G", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 95, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100040832633, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH15 2LH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 4, "created_at": "2018-12-11 15:43:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17511}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, St. Marys Road", "assessment_type": "RdSAP", "completion_date": "2018-12-11", "inspection_date": "2018-12-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-12-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.58, "quantity": "square metres"}, "party_wall_length": {"value": 10, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.56, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.54, "quantity": "metres"}, "total_floor_area": {"value": 38.58, "quantity": "square metres"}, "party_wall_length": {"value": 10, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 120, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.05, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 596, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 491, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1914, "impact_of_loft_insulation": -665, "impact_of_solid_wall_insulation": -894, "space_heating_existing_dwelling": 10901}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 100, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100100976438, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NP23 5PT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EBBW VALE", "built_form": 2, "created_at": "2018-05-08 16:00:29.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1839}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "13, Heol Waen", "address_line_2": "Rassau", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 970, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 879, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2149, "impact_of_loft_insulation": -4333, "space_heating_existing_dwelling": 15035}, "energy_consumption_current": 334, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 226, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10011838361, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SY3 7EU", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "SHREWSBURY", "built_form": 4, "created_at": "2018-06-27 08:44:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "20, Carline Crescent", "assessment_type": "RdSAP", "completion_date": "2018-06-27", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 55, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.93, "quantity": "square metres"}, "party_wall_length": {"value": 15.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 329, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 223, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 107, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 145, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1665, "space_heating_existing_dwelling": 3631}, "energy_consumption_current": 327, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 254, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050900589, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S81 8SF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORKSOP", "built_form": 1, "created_at": "2018-03-16 09:36:18.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "80, Scholey Avenue", "address_line_2": "Woodsetts", "assessment_type": "RdSAP", "completion_date": "2018-03-16", "inspection_date": "2018-03-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.484, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 81.8358, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 38.574, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 694, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 545, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 270, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1977, "impact_of_loft_insulation": -513, "space_heating_existing_dwelling": 11639}, "energy_consumption_current": 269, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 138, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100031769082, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 14% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "ST16 1RS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 2, "created_at": "2018-01-24 12:45:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8794}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Hazel Grove", "assessment_type": "RdSAP", "completion_date": "2018-01-24", "inspection_date": "2018-01-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.47, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 605, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 517, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 125, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2826, "impact_of_loft_insulation": -477, "space_heating_existing_dwelling": 8888}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 127, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10002629250, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [6]}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DN15 6BJ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SCUNTHORPE", "built_form": 4, "created_at": "2018-11-20 16:44:51.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Ground Floor Flat", "address_line_2": "53 Berkeley Street", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-10-11", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.96, "quantity": "square metres"}, "party_wall_length": {"value": 16.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.86, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 180, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.44, "quantity": "square metres"}, "party_wall_length": {"value": 4.41, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.41, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.71, "quantity": "square metres"}, "party_wall_length": {"value": 2.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.34, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 444, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 251, "currency": "GBP"}, "hot_water_cost_current": {"value": 259, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 224, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 202, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 141, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1804, "space_heating_existing_dwelling": 4644}, "energy_consumption_current": 437, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 305, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100070456178, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B24 9DH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-09-10 17:19:07.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9569}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "27, Moor End Lane", "assessment_type": "RdSAP", "completion_date": "2018-09-10", "inspection_date": "2018-09-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.59, "quantity": "square metres"}, "party_wall_length": {"value": 18.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 44.59, "quantity": "square metres"}, "party_wall_length": {"value": 18.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 483, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 128, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2180, "impact_of_loft_insulation": -333, "space_heating_existing_dwelling": 5994}, "energy_consumption_current": 181, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 80, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 90098896, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DY2 0BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DUDLEY", "built_form": 2, "created_at": "2018-02-05 19:44:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9222}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Lawnwood Road", "assessment_type": "RdSAP", "completion_date": "2018-02-05", "inspection_date": "2018-02-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 37.82, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "H", "roof_insulation_thickness": "250mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.82, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 535, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2067, "space_heating_existing_dwelling": 7332}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 103, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10022776696, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true"}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HR9 7JZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 3}, "post_town": "ROSS-ON-WYE", "built_form": 2, "created_at": "2018-07-11 16:11:14.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, LPG", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Barn 1 Crown Barns", "address_line_2": "Lea", "assessment_type": "RdSAP", "completion_date": "2018-07-11", "inspection_date": "2018-07-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-07-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.65, "quantity": "square metres"}, "party_wall_length": {"value": 5.58, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 47.14, "quantity": "square metres"}, "party_wall_length": {"value": 5.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.35, "quantity": "square metres"}, "party_wall_length": {"value": 1.75, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 888, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 743, "currency": "GBP"}, "hot_water_cost_current": {"value": 213, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.1, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 414, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 321, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2287, "space_heating_existing_dwelling": 8965}, "energy_consumption_current": 160, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 74, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100090303703, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CM7 2RS", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRAINTREE", "built_form": 2, "created_at": "2018-09-07 10:45:02.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "50, Peel Crescent", "assessment_type": "RdSAP", "completion_date": "2018-09-07", "inspection_date": "2018-05-03", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.27, "quantity": "metres"}}, "total_floor_area": 52, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.5953, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 59.13, "quantity": "square metres"}, "party_wall_length": {"value": 5.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 507, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 260, "currency": "GBP"}, "hot_water_cost_current": {"value": 311, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 178, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 265, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 211, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2236, "impact_of_cavity_insulation": -2269, "space_heating_existing_dwelling": 5645}, "energy_consumption_current": 495, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 303, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100021178650, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N17 7JN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-03-20 10:29:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "53, Fenton Road", "assessment_type": "RdSAP", "completion_date": "2018-03-20", "inspection_date": "2018-03-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 37.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.32, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 433, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 407, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2094, "impact_of_loft_insulation": -203, "space_heating_existing_dwelling": 7092}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 90, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100021911990, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW9 9NE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-08-24 16:33:01.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "74, Willington Road", "assessment_type": "RdSAP", "completion_date": "2018-08-24", "inspection_date": "2018-08-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.65, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 42.36, "quantity": "square metres"}, "party_wall_length": {"value": 8.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 460, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 327, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 77}}], "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2038, "impact_of_cavity_insulation": -2444, "space_heating_existing_dwelling": 7936}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 139, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 217067588, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 48% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW7 5PU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-01-26 14:37:13.000000", "door_count": 2, "glazed_area": 5, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10324}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "sap_windows": [{"orientation": 1, "window_area": {"value": 3.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 8.1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"orientation": 5, "window_area": {"value": 1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "false", "orientation": 9, "window_area": {"value": 4, "quantity": "square metres"}, "window_type": 2, "glazing_type": 1, "window_location": 0}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "22, Petersham Place", "assessment_type": "RdSAP", "completion_date": "2018-01-26", "inspection_date": "2018-01-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 193, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-01-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 8, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.59, "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 50.52, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.92, "quantity": "metres"}, "total_floor_area": {"value": 50.52, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.84, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.18, "quantity": "metres"}, "total_floor_area": {"value": 43.49, "quantity": "square metres"}, "party_wall_length": {"value": 12.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.88, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.18, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 48, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1061, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 165, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 687, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 73, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 163, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 108, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3000, "impact_of_solid_wall_insulation": -4601, "space_heating_existing_dwelling": 21274}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 73, "calculation_software_version": "3.03r05", "energy_consumption_potential": 89, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 46, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 5300096629, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "N19 4RU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-10-02 00:40:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1727}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "7, Wedmore Street", "assessment_type": "RdSAP", "completion_date": "2018-10-01", "inspection_date": "2018-10-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.11, "quantity": "metres"}}, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.8507, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 260, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 66.98, "quantity": "square metres"}, "party_wall_length": {"value": 6.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 191, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 179, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1962, "space_heating_existing_dwelling": 1327}, "energy_consumption_current": 121, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 96, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100100777725, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 14% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CF72 9SZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTYCLUN", "built_form": 2, "created_at": "2018-11-07 10:52:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "11, Trenos Gardens", "address_line_2": "Bryncae, Llanharan", "assessment_type": "RdSAP", "completion_date": "2018-11-07", "inspection_date": "2018-11-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-11-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.35, "quantity": "square metres"}, "party_wall_length": {"value": 8.18, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 377, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 307, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2856, "impact_of_cavity_insulation": -941, "space_heating_existing_dwelling": 5700}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 55, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100081142023, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WD25 9NF", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WATFORD", "built_form": 4, "created_at": "2018-10-11 14:43:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 8 Parkview", "address_line_2": "Bucknalls Close", "assessment_type": "RdSAP", "completion_date": "2018-10-11", "inspection_date": "2018-10-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 2.9}, "total_floor_area": 37, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-10-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.699, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 245, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.11, "quantity": "square metres"}, "party_wall_length": {"value": 21.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 242, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 157, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1467, "space_heating_existing_dwelling": 2491}, "energy_consumption_current": 343, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 277, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W14 9JS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-10-30 09:00:21.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Top Floor Flat", "address_line_2": "20 Vereker Road", "assessment_type": "RdSAP", "completion_date": "2018-10-30", "inspection_date": "2018-10-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 0.9, "quantity": "metres"}}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-10-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.205, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 46.909, "quantity": "square metres"}, "party_wall_length": {"value": 8.695, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.485, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 481, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 392, "currency": "GBP"}, "hot_water_cost_current": {"value": 70, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}], "co2_emissions_potential": 2.1, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1583, "impact_of_loft_insulation": -3914, "impact_of_solid_wall_insulation": -1709, "space_heating_existing_dwelling": 8424}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 255, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100110021495, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TS25 3QW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARTLEPOOL", "built_form": 4, "created_at": "2018-11-05 15:23:23.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9897}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "7, Monach Road", "assessment_type": "RdSAP", "completion_date": "2018-11-05", "inspection_date": "2018-10-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-11-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.428, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.21, "quantity": "square metres"}, "party_wall_length": {"value": 9.278, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.267, "quantity": "metres"}, "total_floor_area": {"value": 35.21, "quantity": "square metres"}, "party_wall_length": {"value": 9.278, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 411, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 394, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2725, "impact_of_loft_insulation": -378, "space_heating_existing_dwelling": 6771}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 98, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010489494, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA4 4RL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MORECAMBE", "built_form": 2, "created_at": "2018-11-09 21:10:01", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "19, Leamington Road", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-11-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 28.8, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "E"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.9, "quantity": "square metres"}, "party_wall_length": {"value": 9.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 895, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 516, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 243, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 143, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2164, "impact_of_loft_insulation": -1529, "space_heating_existing_dwelling": 13103}, "energy_consumption_current": 334, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 116, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 64014210, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF62 4JP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARRY", "built_form": 2, "created_at": "2018-12-17 13:50:30.000000", "door_count": 2, "glazed_area": 4, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "sap_windows": [{"orientation": 3, "window_area": {"value": 0.4, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0}, {"orientation": 1, "window_area": {"value": 0.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 7, "window_area": {"value": 0.9, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 3, "window_area": {"value": 1.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 7, "window_area": {"value": 1.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 5, "window_area": {"value": 1.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 7, "window_area": {"value": 1.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 3, "window_area": {"value": 2.1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 7, "window_area": {"value": 2.1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 3, "window_area": {"value": 1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 7, "window_area": {"value": 3.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 6, "orientation": 3, "window_area": {"value": 1.6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Chestnut Avenue", "address_line_2": "St. Athan", "assessment_type": "RdSAP", "completion_date": "2018-12-17", "inspection_date": "2018-11-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-12-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 26.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.72, "quantity": "square metres"}, "party_wall_length": {"value": 3.74, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 21.72, "quantity": "square metres"}, "party_wall_length": {"value": 3.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 778, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2011, "impact_of_solid_wall_insulation": -6724, "space_heating_existing_dwelling": 15066}, "energy_consumption_current": 266, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 82, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10010146391, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LE18 1PA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WIGSTON", "built_form": 2, "created_at": "2018-10-23 17:55:32.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4 Redwood Court", "address_line_2": "Bull Head Street", "assessment_type": "RdSAP", "completion_date": "2018-10-23", "inspection_date": "2018-10-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.36, "quantity": "metres"}}, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-10-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.032, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 65.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 207, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 173, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 89, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 168, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1784, "space_heating_existing_dwelling": 2117}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 186, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100030596124, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 73% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE18 4XS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIGSTON", "built_form": 2, "created_at": "2018-11-09 08:09:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50, Kenilworth Road", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-10-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 35.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 471, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2187, "impact_of_loft_insulation": -224, "space_heating_existing_dwelling": 8142}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10002326418, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD22 7BQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KEIGHLEY", "built_form": 2, "created_at": "2018-11-22 20:19:53.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8215}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Majestic Way", "assessment_type": "RdSAP", "completion_date": "2018-11-22", "inspection_date": "2018-11-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-11-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 500, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2016, "space_heating_existing_dwelling": 7194}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 133, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200001428073, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E17 4JN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-12-19 16:52:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "256, St. John's Road", "assessment_type": "RdSAP", "completion_date": "2018-12-19", "inspection_date": "2018-12-19", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.11, "quantity": "metres"}}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.148, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.27, "quantity": "square metres"}, "party_wall_length": {"value": 14.65, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 351, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 33, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 235, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1570, "impact_of_solid_wall_insulation": -845, "space_heating_existing_dwelling": 4586}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 171, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100031435751, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG21 0AH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANSFIELD", "built_form": 2, "created_at": "2018-11-28 15:59:59.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "75, Station Road", "address_line_2": "Rainworth", "assessment_type": "RdSAP", "completion_date": "2018-11-28", "inspection_date": "2018-11-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-11-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.84, "quantity": "square metres"}, "party_wall_length": {"value": 5.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.84, "quantity": "square metres"}, "party_wall_length": {"value": 5.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.86, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 475, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 435, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2092, "space_heating_existing_dwelling": 8230}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 12013672, "roofs": [{"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "UB5 6HU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "NORTHOLT", "built_form": 3, "created_at": "2018-12-24 17:13:58.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "183 Woburn Tower", "address_line_2": "Broomcroft Avenue", "assessment_type": "RdSAP", "completion_date": "2018-12-24", "inspection_date": "2018-12-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 9, "heat_loss_corridor": 2, "unheated_corridor_length": 16.73}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 39.1482, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 260, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 69.99, "quantity": "square metres"}, "party_wall_length": {"value": 6.47, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 521, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 365, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.2, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2275, "space_heating_existing_dwelling": 9286}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 176, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031604109, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG6 0BA", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-11-23 21:48:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1296}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "540, Vernon Road", "assessment_type": "RdSAP", "completion_date": "2018-11-23", "inspection_date": "2018-11-23", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.31, "quantity": "square metres"}, "party_wall_length": {"value": 14.66, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.88, "quantity": "metres"}, "total_floor_area": {"value": 29.83, "quantity": "square metres"}, "party_wall_length": {"value": 14.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 9.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.92, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 810, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 346, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 71, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 208, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 256, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 154, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 306, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5178, "impact_of_loft_insulation": -258, "impact_of_cavity_insulation": -240, "impact_of_solid_wall_insulation": -3499, "space_heating_existing_dwelling": 11203}, "energy_consumption_current": 412, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 71, "calculation_software_version": "3.08r07", "energy_consumption_potential": 94, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100051282616, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BD18 2NF", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SHIPLEY", "built_form": 4, "created_at": "2018-01-23 16:37:56.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "13, Fountain Way", "assessment_type": "RdSAP", "completion_date": "2018-01-23", "inspection_date": "2017-11-08", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.2, "quantity": "metres"}}, "total_floor_area": 54, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-01-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.376, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 62.87, "quantity": "square metres"}, "party_wall_length": {"value": 9.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 512, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 260, "currency": "GBP"}, "hot_water_cost_current": {"value": 349, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 187, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 232, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 229, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 136, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2560, "impact_of_cavity_insulation": -1802, "impact_of_solid_wall_insulation": -708, "space_heating_existing_dwelling": 5764}, "energy_consumption_current": 499, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 294, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 40009497, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L36 2PZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-07-23 11:06:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Coral Avenue", "assessment_type": "RdSAP", "completion_date": "2018-07-23", "inspection_date": "2018-07-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.83, "quantity": "square metres"}, "party_wall_length": {"value": 6.86, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.34, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 34.99, "quantity": "square metres"}, "party_wall_length": {"value": 13.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 637, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 59}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2034, "impact_of_loft_insulation": -469, "impact_of_cavity_insulation": -522, "impact_of_solid_wall_insulation": -2657, "space_heating_existing_dwelling": 10607}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 111, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100010207384, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CW7 1ED", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WINSFORD", "built_form": 3, "created_at": "2018-10-24 18:58:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 571}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Chestnut Grove", "assessment_type": "RdSAP", "completion_date": "2018-10-24", "inspection_date": "2018-10-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 43.8, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 935, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 452, "currency": "GBP"}, "hot_water_cost_current": {"value": 266, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 188, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 265, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3827, "impact_of_loft_insulation": -685, "impact_of_cavity_insulation": -2978, "space_heating_existing_dwelling": 12730}, "energy_consumption_current": 408, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 102, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 72, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090770600, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR20 3RA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DEREHAM", "built_form": 2, "created_at": "2018-05-23 17:51:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "32, Crosskeys Way", "address_line_2": "Mattishall", "assessment_type": "RdSAP", "completion_date": "2018-05-23", "inspection_date": "2018-05-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 3, "registration_date": "2018-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 8.16, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 8.7, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.97, "quantity": "square metres"}, "party_wall_length": {"value": 8.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.72, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 467, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1789, "space_heating_existing_dwelling": 9010}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 124, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100020226283, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DA8 1JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ERITH", "built_form": 4, "created_at": "2018-07-25 08:44:16.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Brook Vale", "assessment_type": "RdSAP", "completion_date": "2018-07-25", "inspection_date": "2018-07-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-07-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.7, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.7, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 422, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 312, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2122, "impact_of_loft_insulation": -242, "impact_of_solid_wall_insulation": -2361, "space_heating_existing_dwelling": 6551}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 51, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10013328811, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR32 2LX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LOWESTOFT", "built_form": 3, "created_at": "2018-01-28 17:12:59.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 16682}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "174, St. Peters Street", "assessment_type": "RdSAP", "completion_date": "2018-01-28", "inspection_date": "2018-01-23", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-01-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 53.18, "quantity": "square metres"}, "party_wall_length": {"value": 9.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.68, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "50mm"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.17, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 251, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1591, "space_heating_existing_dwelling": 3412}, "energy_consumption_current": 144, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 139, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100021463957, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HA4 9BY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUISLIP", "built_form": 2, "created_at": "2018-10-24 08:37:57.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "79, Lynmouth Drive", "assessment_type": "RdSAP", "completion_date": "2018-10-24", "inspection_date": "2018-10-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-10-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.17, "quantity": "square metres"}, "party_wall_length": {"value": 6.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 36.17, "quantity": "square metres"}, "party_wall_length": {"value": 6.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.53, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 556, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 562, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2220, "impact_of_loft_insulation": -214, "space_heating_existing_dwelling": 7450}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 128, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050496854, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO21 3EG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WHITBY", "built_form": 4, "created_at": "2018-06-03 22:58:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "5 Church square", "assessment_type": "RdSAP", "completion_date": "2018-06-03", "inspection_date": "2018-05-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.28, "quantity": "metres"}}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 30.84, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "total_floor_area": {"value": 49.69, "quantity": "square metres"}, "party_wall_length": {"value": 9.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 497, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 293, "currency": "GBP"}, "hot_water_cost_current": {"value": 71, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 204, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1563, "impact_of_solid_wall_insulation": -3631, "space_heating_existing_dwelling": 6829}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 169, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10024331167, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully triple glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 92% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B2 4PA", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-10-02 13:07:29.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Apartment 200", "address_line_2": "The Rotunda", "address_line_3": "150 New Street", "assessment_type": "RdSAP", "completion_date": "2018-10-02", "inspection_date": "2018-09-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 15.6}, "total_floor_area": 105, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 37.44, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 52.65, "quantity": "square metres"}, "party_wall_length": {"value": 13.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 52.65, "quantity": "square metres"}, "party_wall_length": {"value": 13.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 509, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 6, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 283, "currency": "GBP"}, "hot_water_cost_current": {"value": 234, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 192, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 94, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 426, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 364, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 258, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1412, "space_heating_existing_dwelling": 3074}, "energy_consumption_current": 146, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 147, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100062513536, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO17 3ST", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2018-05-06 15:43:03.000000", "door_count": 0, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "719, Portswood Road", "assessment_type": "RdSAP", "completion_date": "2018-05-06", "inspection_date": "2018-04-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 19, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-05-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 278, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 19.34, "quantity": "square metres"}, "party_wall_length": {"value": 8.21, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 388, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 100, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 6, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 210, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 147, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 824, "impact_of_cavity_insulation": -596, "space_heating_existing_dwelling": 2407}, "energy_consumption_current": 532, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r04", "energy_consumption_potential": 326, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 1, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 90, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100091021124, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP27 9RQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}, "post_town": "BRANDON", "built_form": 3, "created_at": "2018-04-03 16:51:55", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2204, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 102750}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, radiators, electric", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17 Spruce Close", "address_line_2": "RAF Lakenheath", "assessment_type": "RdSAP", "completion_date": "2018-04-03", "inspection_date": "2018-03-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.44, "quantity": "square metres"}, "party_wall_length": {"value": 3.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 54.28, "quantity": "square metres"}, "party_wall_length": {"value": 3.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 736, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 572, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2825, "space_heating_existing_dwelling": 11903}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 78, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 207041211, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N9 8NW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-30 11:38:50.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Emsworth Close", "address_line_2": "St. Mary's Road", "assessment_type": "RdSAP", "completion_date": "2018-11-30", "inspection_date": "2018-11-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-11-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.96, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 36.96, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 758, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 569, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2048, "impact_of_loft_insulation": -2502, "impact_of_cavity_insulation": -3109, "space_heating_existing_dwelling": 13729}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 162, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100030299544, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE22 1JG", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 4, "created_at": "2018-11-28 17:20:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 10 Dayton Court", "address_line_2": "Cedar Street", "assessment_type": "RdSAP", "completion_date": "2018-11-28", "inspection_date": "2018-11-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-11-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 35.77, "quantity": "square metres"}, "party_wall_length": {"value": 16.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 140, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 140, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1728, "space_heating_existing_dwelling": 951}, "energy_consumption_current": 153, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 153, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060904791, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CT16 2QL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DOVER", "built_form": 4, "created_at": "2018-09-28 13:39:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Evison Close", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.9, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 35.9, "quantity": "square metres"}, "party_wall_length": {"value": 16.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 375, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 393, "currency": "GBP"}, "hot_water_cost_current": {"value": 175, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3422, "impact_of_loft_insulation": -401, "space_heating_existing_dwelling": 5485}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 88, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100090206698, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE3 9YU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 3, "created_at": "2018-08-30 10:54:33.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4033}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "74, Manton", "address_line_2": "Bretton", "assessment_type": "RdSAP", "completion_date": "2018-08-30", "inspection_date": "2018-08-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-08-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.44, "quantity": "square metres"}, "party_wall_length": {"value": 8.14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 44.44, "quantity": "square metres"}, "party_wall_length": {"value": 8.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.73, "quantity": "square metres"}, "party_wall_length": {"value": 2.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 576, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 440, "currency": "GBP"}, "hot_water_cost_current": {"value": 154, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2879, "impact_of_loft_insulation": -683, "space_heating_existing_dwelling": 9098}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 89, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100022526429, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "E11 3NL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-10-03 13:33:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "307, Cann Hall Road", "assessment_type": "RdSAP", "completion_date": "2018-10-03", "inspection_date": "2018-09-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.65, "quantity": "square metres"}, "party_wall_length": {"value": 19.97, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.56, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 51.65, "quantity": "square metres"}, "party_wall_length": {"value": 19.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 726, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 7, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2270, "impact_of_loft_insulation": -1192, "impact_of_solid_wall_insulation": -3529, "space_heating_existing_dwelling": 13018}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 67, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 15059139, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN5 7ND", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 2, "created_at": "2018-09-01 21:32:20.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17955}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Welland Way", "assessment_type": "RdSAP", "completion_date": "2018-09-01", "inspection_date": "2018-08-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 42.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 436, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 400, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 48, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1765, "space_heating_existing_dwelling": 7392}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 76, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 3040010885, "roofs": [{"description": {"value": "Flat, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG2 7JL", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-07-03 15:16:25.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "5, Springfields", "address_line_2": "Loughborough Road", "assessment_type": "RdSAP", "completion_date": "2018-07-03", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.35, "quantity": "metres"}}, "total_floor_area": 51, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.84, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 51.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "50mm"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 549, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 337, "currency": "GBP"}, "hot_water_cost_current": {"value": 205, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a31,600 - \u00a32,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 56}], "co2_emissions_potential": 2.9, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 177, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 93}, {"sequence": 3, "typical_saving": {"value": 147, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 156, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2231, "impact_of_cavity_insulation": -225, "space_heating_existing_dwelling": 5771}, "energy_consumption_current": 497, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 339, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 84, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 83171779, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF12 0HQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DEWSBURY", "built_form": 2, "created_at": "2018-06-29 11:43:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "49, Smithy Parade", "assessment_type": "RdSAP", "completion_date": "2018-06-29", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.17, "quantity": "square metres"}, "party_wall_length": {"value": 5.99, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.07, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 39.17, "quantity": "square metres"}, "party_wall_length": {"value": 5.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.07, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 663, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 626, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2094, "impact_of_loft_insulation": -3677, "space_heating_existing_dwelling": 10879}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 175, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100030399227, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE9 4JL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 3}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2018-11-28 10:43:34", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2204, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "true", "main_heating_data_source": 1, "main_heating_index_number": 100063}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Air source heat pump, radiators, electric", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "24, Pougher Close", "address_line_2": "Sapcote", "assessment_type": "RdSAP", "completion_date": "2018-11-28", "inspection_date": "2018-11-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.59, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 41.41, "quantity": "square metres"}, "party_wall_length": {"value": 6.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 487, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 385, "currency": "GBP"}, "hot_water_cost_current": {"value": 377, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 250, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2722, "space_heating_existing_dwelling": 11559}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 90, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 422000091784, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OL4 3EZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OLDHAM", "built_form": 3, "created_at": "2018-05-12 12:17:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "47, Lynwood Drive", "assessment_type": "RdSAP", "completion_date": "2018-05-12", "inspection_date": "2018-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.16, "quantity": "square metres"}, "party_wall_length": {"value": 6.96, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.16, "quantity": "square metres"}, "party_wall_length": {"value": 6.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 558, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 451, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2053, "impact_of_loft_insulation": -245, "space_heating_existing_dwelling": 8333}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 122, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100071146402, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WV3 8AE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 2, "created_at": "2018-07-12 17:30:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10265}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "24, Chestnut Way", "assessment_type": "RdSAP", "completion_date": "2018-07-12", "inspection_date": "2018-07-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 107, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 790, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 662, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2260, "impact_of_loft_insulation": -247, "impact_of_cavity_insulation": -1967, "space_heating_existing_dwelling": 13749}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 144, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 43085381, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NP11 4NG", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NEWPORT", "built_form": 4, "created_at": "2018-08-12 13:40:24.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 633, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 120}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4 Bryngwyn Cottages", "address_line_2": "Newbridge", "assessment_type": "RdSAP", "completion_date": "2018-08-12", "inspection_date": "2018-08-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-08-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 510, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.44, "quantity": "square metres"}, "party_wall_length": {"value": 10.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 37.44, "quantity": "square metres"}, "party_wall_length": {"value": 10.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1169, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 810, "currency": "GBP"}, "hot_water_cost_current": {"value": 341, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 182, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2063, "impact_of_loft_insulation": -227, "impact_of_solid_wall_insulation": -3563, "space_heating_existing_dwelling": 13861}, "energy_consumption_current": 359, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 181, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200001376566, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG7 7GU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-06-11 16:08:41.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Chard Street", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.6, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 34.6, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 946, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 264, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 229, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 5, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 6, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 7, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 8, "typical_saving": {"value": 163, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 9, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 10, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 11, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 201, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3716, "impact_of_solid_wall_insulation": -3434, "space_heating_existing_dwelling": 12495}, "energy_consumption_current": 486, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 99, "environmental_impact_current": 33, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 86, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100061721794, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BN16 2DD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LITTLEHAMPTON", "built_form": 1, "created_at": "2018-06-11 14:14:05.000000", "door_count": 2, "glazed_area": 2, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15935}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "14, Meadway", "address_line_2": "Rustington", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 205, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 58.96, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "I"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 96.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 38, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1049, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 192, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 966, "currency": "GBP"}, "hot_water_cost_current": {"value": 154, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": 75, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 330, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 4.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 96, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 154, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3397, "impact_of_loft_insulation": -220, "space_heating_existing_dwelling": 16632}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 117, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100110334032, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LA11 7JG", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "GRANGE-OVER-SANDS", "built_form": 2, "created_at": "2018-05-14 18:45:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 601, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Portable electric heaters assumed for most rooms", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Fell Close", "assessment_type": "RdSAP", "completion_date": "2018-05-14", "inspection_date": "2018-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-05-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.96, "quantity": "square metres"}, "party_wall_length": {"value": 6.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.68, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 42.96, "quantity": "square metres"}, "party_wall_length": {"value": 6.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 2077, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.5, "energy_rating_average": 60, "energy_rating_current": 16, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 431, "currency": "GBP"}, "hot_water_cost_current": {"value": 386, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 17, "environmental_impact_rating": 30}, {"sequence": 2, "typical_saving": {"value": 417, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 27, "environmental_impact_rating": 38}, {"sequence": 3, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 30, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 42}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 43}, {"sequence": 7, "typical_saving": {"value": 1181, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 8, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 9, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 10, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 221, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 32, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 1110, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 992, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 1199, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2395, "impact_of_loft_insulation": -442, "impact_of_cavity_insulation": -2875, "space_heating_existing_dwelling": 13723}, "energy_consumption_current": 580, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "2.0.x", "energy_consumption_potential": 94, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "G", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 99, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100012378213, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 42% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WA7 3BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUNCORN", "built_form": 1, "created_at": "2018-09-11 18:56:37", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17503}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "A M & J K Currie", "address_line_2": "Rossbottom Farm, Chester Road", "address_line_3": "Preston Brook", "assessment_type": "RdSAP", "completion_date": "2018-09-11", "inspection_date": "2018-09-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-09-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.13, "quantity": "metres"}, "total_floor_area": {"value": 53.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 949, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 519, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}, {"sequence": 7, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 102, "environmental_impact_rating": 101}], "co2_emissions_potential": -0.2, "energy_rating_potential": 102, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2055, "impact_of_loft_insulation": -483, "impact_of_solid_wall_insulation": -6858, "space_heating_existing_dwelling": 17808}, "energy_consumption_current": 258, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": -6, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 101, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 11026663, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DN37 0DU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GRIMSBY", "built_form": 2, "created_at": "2018-09-13 15:39:52.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "23, Westfield Road", "address_line_2": "Waltham", "assessment_type": "RdSAP", "completion_date": "2018-09-13", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 45, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 470, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 347, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 39, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1626, "space_heating_existing_dwelling": 6548}, "energy_consumption_current": 346, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200000641093, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU11 4LL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 1, "created_at": "2018-12-11 20:58:55", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2204, "main_heating_category": 4, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 103158}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Air source heat pump, radiators, electric", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Grange Cottage", "address_line_2": "Thirtleby", "assessment_type": "RdSAP", "completion_date": "2018-12-11", "inspection_date": "2018-12-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 194, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-12-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [9], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 59.24, "quantity": "square metres"}, "insulation": 3, "roof_room_connected": "N", "construction_age_band": "F", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 91.66, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 32.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 17.59, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "L", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1092, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 811, "currency": "GBP"}, "hot_water_cost_current": {"value": 290, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 5, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "co2_emissions_potential": 2.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 198, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3000, "space_heating_existing_dwelling": 20388}, "energy_consumption_current": 141, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 22, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100030499124, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LE10 2DB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HINCKLEY", "built_form": 4, "created_at": "2018-05-11 13:11:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8442}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "115, Church Street", "address_line_2": "Burbage", "assessment_type": "RdSAP", "completion_date": "2018-05-11", "inspection_date": "2018-05-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.11, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.19, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.11, "quantity": "metres"}, "total_floor_area": {"value": 24.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.11, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.53, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.11, "quantity": "metres"}, "total_floor_area": {"value": 8.53, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 821, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 161, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 8, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 9, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 10, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 11, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1954, "impact_of_loft_insulation": -2179, "impact_of_solid_wall_insulation": -2867, "space_heating_existing_dwelling": 11884}, "energy_consumption_current": 405, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 97, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW17 8RB", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-16 10:34:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8574}], "immersion_heating_type": "NA", "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "36c Huron Road", "assessment_type": "RdSAP", "completion_date": "2018-06-16", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 0.9, "quantity": "metres"}}, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.07, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 62.38, "quantity": "square metres"}, "party_wall_length": {"value": 16.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 205, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 208, "currency": "GBP"}, "hot_water_cost_current": {"value": 516, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 8446, "impact_of_loft_insulation": -797, "impact_of_solid_wall_insulation": -3, "space_heating_existing_dwelling": 1688}, "energy_consumption_current": 324, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 124, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050448159, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 36% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "YO17 6SR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "MALTON", "built_form": 2, "created_at": "2018-09-11 23:33:49.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16844}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Sandy Lee", "address_line_2": "Middle Street", "address_line_3": "Swinton", "assessment_type": "RdSAP", "completion_date": "2018-09-11", "inspection_date": "2018-09-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.37, "quantity": "square metres"}, "party_wall_length": {"value": 7.61, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37.37, "quantity": "square metres"}, "party_wall_length": {"value": 7.61, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 8.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1023, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 906, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "2,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.7, "energy_rating_potential": 63, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2233, "impact_of_loft_insulation": -485, "space_heating_existing_dwelling": 11520}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 126, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100100073373, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF11 8AP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 2, "created_at": "2018-06-11 11:20:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "68, Leckwith Road", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 80, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 80, "quantity": "square metres"}, "party_wall_length": {"value": 9.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 400, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 360, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2110, "impact_of_loft_insulation": -855, "space_heating_existing_dwelling": 6161}, "energy_consumption_current": 171, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 156, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 30509490, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TA13 5LB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SOUTH PETHERTON", "built_form": 2, "created_at": "2018-06-12 07:26:36.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1187}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Springers Barn", "address_line_2": "Over Stratton", "assessment_type": "RdSAP", "completion_date": "2018-06-12", "inspection_date": "2018-06-11", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-06-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.5, "quantity": "square metres"}, "party_wall_length": {"value": 6.87, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.88, "quantity": "square metres"}, "party_wall_length": {"value": 6.87, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 9.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.42, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 835, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.1, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 528, "currency": "GBP"}, "hot_water_cost_current": {"value": 191, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 6, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 7, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 49, "environmental_impact_rating": 42}}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3419, "impact_of_loft_insulation": -286, "impact_of_cavity_insulation": -2297, "space_heating_existing_dwelling": 13226}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 100, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100020388436, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BR3 6SL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BECKENHAM", "built_form": 1, "created_at": "2018-10-16 16:55:03", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "30, Woodmere Way", "assessment_type": "RdSAP", "completion_date": "2018-10-16", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 194, "transaction_type": 11, "conservatory_type": 4, "heated_room_count": 8, "pvc_window_frames": "false", "registration_date": "2018-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 2, "peak_power": {"value": 5.6, "quantity": "kW"}, "orientation": 4, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"floor_area": {"value": 30, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 16, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 18, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.74, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 93, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 38.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1178, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 865, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 96, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3406, "impact_of_solid_wall_insulation": -5673, "space_heating_existing_dwelling": 22844}, "energy_consumption_current": 131, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 67, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 200000885270, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DN15 8YL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SCUNTHORPE", "built_form": 1, "created_at": "2018-04-13 11:15:08.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5922}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "11, Pippin Court", "assessment_type": "RdSAP", "completion_date": "2018-04-13", "inspection_date": "2018-04-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-04-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 53.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.49, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 737, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 631, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 87, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 221, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3128, "space_heating_existing_dwelling": 10624}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 125, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100061831483, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH20 3LP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PULBOROUGH", "built_form": 1, "created_at": "2018-09-18 08:01:09.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 4084}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Rectory Close", "address_line_2": "Ashington", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.41, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 24.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 3.37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 493, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 427, "currency": "GBP"}, "hot_water_cost_current": {"value": 165, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2834, "impact_of_loft_insulation": -189, "space_heating_existing_dwelling": 6611}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 90, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10094401316, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Granite or whinstone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PL11 2AB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "TORPOINT", "built_form": 3, "created_at": "2018-07-14 01:17:53.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 191, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat B", "address_line_2": "9 Fore Street", "assessment_type": "RdSAP", "completion_date": "2018-07-14", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.27, "quantity": "metres"}}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 720, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.65, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 130, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.69, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 152, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 164, "currency": "GBP"}, "hot_water_cost_current": {"value": 239, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 202, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1445, "space_heating_existing_dwelling": 798}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 192, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100000007892, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE39 2DD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROWLANDS GILL", "built_form": 2, "created_at": "2018-12-11 13:53:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "3, William Morris Avenue", "assessment_type": "RdSAP", "completion_date": "2018-12-11", "inspection_date": "2018-12-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 46, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-12-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.5, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 425, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1629, "space_heating_existing_dwelling": 7279}, "energy_consumption_current": 327, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 132, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100091541656, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR1 2AW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORWICH", "built_form": 2, "created_at": "2018-04-11 09:53:51.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1695}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "5, Abbey Court", "address_line_2": "Bracondale", "assessment_type": "RdSAP", "completion_date": "2018-04-11", "inspection_date": "2018-04-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.39, "quantity": "metres"}}, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.8843, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 66.76, "quantity": "square metres"}, "party_wall_length": {"value": 7.31, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 393, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 79}}], "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1959, "impact_of_cavity_insulation": -1313, "impact_of_solid_wall_insulation": -696, "space_heating_existing_dwelling": 5065}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 134, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100051211889, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BD15 9JD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRADFORD", "built_form": 2, "created_at": "2018-05-12 10:52:17.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16976}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "19, Rosedale Avenue", "address_line_2": "Allerton", "assessment_type": "RdSAP", "completion_date": "2018-05-12", "inspection_date": "2018-05-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.79, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.79, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.2, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 16.2, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 851, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 662, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 88, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 159, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1843, "impact_of_loft_insulation": -1575, "impact_of_cavity_insulation": -3211, "space_heating_existing_dwelling": 14703}, "energy_consumption_current": 403, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 86, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 221, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100062093757, "roofs": [{"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CT10 1RY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BROADSTAIRS", "built_form": 4, "created_at": "2018-01-13 10:36:41.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1830}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 11 Charleston Court", "address_line_2": "61, West Cliff Road", "assessment_type": "RdSAP", "completion_date": "2018-01-13", "inspection_date": "2017-08-11", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.4, "quantity": "metres"}}, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-01-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.656, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 87.5, "quantity": "square metres"}, "party_wall_length": {"value": 16.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 4.95, "quantity": "square metres"}, "party_wall_length": {"value": 1.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 235, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 223, "currency": "GBP"}, "hot_water_cost_current": {"value": 170, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 98, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 86}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2883, "space_heating_existing_dwelling": 2242}, "energy_consumption_current": 123, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 80, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100023055321, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IG8 9QN", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WOODFORD GREEN", "built_form": 5, "created_at": "2018-09-11 18:53:53.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 601, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "10, Payzes Gardens", "address_line_2": "Chingford Lane", "assessment_type": "RdSAP", "completion_date": "2018-09-11", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 5.01}, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-09-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.1743, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 61.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 465, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 157, "currency": "GBP"}, "hot_water_cost_current": {"value": 340, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 235, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 286, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 237, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 87}, {"sequence": 3, "typical_saving": {"value": 206, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2340, "impact_of_solid_wall_insulation": -2728, "space_heating_existing_dwelling": 4093}, "energy_consumption_current": 306, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 100, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 40784, "roofs": [{"description": "Pitched, 12 mm loft insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 10% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BS9 4HU", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2018-04-11 15:00:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 506, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Warm air, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "18, Farne Close", "assessment_type": "RdSAP", "completion_date": "2018-04-11", "inspection_date": "2018-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.6, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.7, "quantity": "square metres"}, "party_wall_length": {"value": 7.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 44.4, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "12mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 844, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 322, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "2,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 237, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5220, "impact_of_loft_insulation": -2319, "impact_of_cavity_insulation": -2428, "impact_of_solid_wall_insulation": -225, "space_heating_existing_dwelling": 11941}, "energy_consumption_current": 390, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 108, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 12092955, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W5 3BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2018-09-11 16:12:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1966}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Heathcroft", "assessment_type": "RdSAP", "completion_date": "2018-09-11", "inspection_date": "2018-09-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-09-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.62, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 52.62, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1161, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 762, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 60, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 177, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.3, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 223, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 55}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2803, "impact_of_loft_insulation": -3492, "impact_of_cavity_insulation": -3994, "space_heating_existing_dwelling": 20195}, "energy_consumption_current": 355, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 166, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060932858, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DA12 1HQ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "GRAVESEND", "built_form": 6, "created_at": "2018-06-11 18:20:36.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "98 Homemead", "address_line_2": "Homemead Close", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 8, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 10.4, "quantity": "metres"}}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 24.44, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 47.8, "quantity": "square metres"}, "party_wall_length": {"value": 9.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 748, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 42}], "co2_emissions_potential": 4.0, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 313, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 223, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1689, "impact_of_cavity_insulation": -1179, "space_heating_existing_dwelling": 8360}, "energy_consumption_current": 660, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 492, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 42, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 112, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10007948625, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 30% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SK9 1AW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WILMSLOW", "built_form": 1, "created_at": "2018-09-12 10:32:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Apartment 18 Carrs Court", "address_line_2": "Church Street", "assessment_type": "RdSAP", "completion_date": "2018-09-12", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 12.5}, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 28.25, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 295, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 78.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 38.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 317, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 325, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2250, "space_heating_existing_dwelling": 3379}, "energy_consumption_current": 140, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 132, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100021055945, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N16 0JH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-07-29 23:19:31.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 83 Denman House", "address_line_2": "Lordship Terrace", "assessment_type": "RdSAP", "completion_date": "2018-07-29", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 44.48, "quantity": "square metres"}, "party_wall_length": {"value": 6.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 302, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 164, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2294, "impact_of_solid_wall_insulation": -2297, "space_heating_existing_dwelling": 3313}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 128, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100030454518, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE7 7PW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 1, "created_at": "2018-05-11 19:49:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15169}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "196, Mountsorrel Lane", "address_line_2": "Rothley", "assessment_type": "RdSAP", "completion_date": "2018-05-11", "inspection_date": "2018-05-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 136, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "registration_date": "2018-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.31, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 64.63, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 32.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 8, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 5.12, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 9.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1519, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 596, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 427, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 94, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2309, "impact_of_solid_wall_insulation": -8488, "space_heating_existing_dwelling": 29604}, "energy_consumption_current": 342, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 97, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200004723661, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG8 9NJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "READING", "built_form": 2, "created_at": "2018-04-11 11:25:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17619}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "1 Church Farm Cottages", "address_line_2": "Lower Basildon", "assessment_type": "RdSAP", "completion_date": "2018-04-11", "inspection_date": "2018-04-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 35.68, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "300mm"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.46, "quantity": "square metres"}, "party_wall_length": {"value": 3.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.17, "quantity": "square metres"}, "party_wall_length": {"value": 2.11, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 641, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 176, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2697, "impact_of_loft_insulation": -184, "impact_of_solid_wall_insulation": -2635, "space_heating_existing_dwelling": 15200}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 72, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 163872, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS13 8PJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 4, "created_at": "2018-07-19 16:17:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "9, Lakemead Gardens", "assessment_type": "RdSAP", "completion_date": "2018-07-19", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.42, "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 43.71, "quantity": "square metres"}, "party_wall_length": {"value": 14.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 277, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 241, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}}], "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1760, "impact_of_cavity_insulation": -129, "space_heating_existing_dwelling": 3712}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "3.05r03", "energy_consumption_potential": 174, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100012389271, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "FY8 1LZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LYTHAM ST. ANNES", "built_form": 2, "created_at": "2018-06-14 15:25:12.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17759}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "2 The Annexe Devere Gardens", "address_line_2": "49, South Promenade", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "total_floor_area": {"value": 113.3, "quantity": "square metres"}, "party_wall_length": {"value": 22.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 34.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 504, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 386, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 87, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 80}}], "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2281, "impact_of_cavity_insulation": -2503, "space_heating_existing_dwelling": 8155}, "energy_consumption_current": 152, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 24, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 10003952992, "roofs": [{"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA17 7TF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KIRKBY-IN-FURNESS", "built_form": 1, "created_at": "2018-04-12 07:59:53", "door_count": 2, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 17503}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Stone Arthur", "address_line_2": "School Road", "assessment_type": "RdSAP", "completion_date": "2018-04-12", "inspection_date": "2018-04-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 204, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "registration_date": "2018-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 42.4, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "L", "roof_insulation_thickness": "100mm"}, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.11, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 56.06, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.96, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1014, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1014, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}], "co2_emissions_potential": 4.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 110, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2117, "impact_of_loft_insulation": -160, "space_heating_existing_dwelling": 19239}, "energy_consumption_current": 156, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 129, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 100010899724, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BL1 4HT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 4, "created_at": "2018-12-20 11:57:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Longden Street", "assessment_type": "RdSAP", "completion_date": "2018-12-20", "inspection_date": "2018-12-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-12-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.92, "quantity": "square metres"}, "party_wall_length": {"value": 16.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.86, "quantity": "metres"}, "total_floor_area": {"value": 32.92, "quantity": "square metres"}, "party_wall_length": {"value": 16.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 632, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 634, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1946, "impact_of_loft_insulation": -3154, "space_heating_existing_dwelling": 10164}, "energy_consumption_current": 310, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 216, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10000228906, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CV12 9HG", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BEDWORTH", "built_form": 6, "created_at": "2018-11-26 13:10:04.000000", "door_count": 1, "glazed_area": 3, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "15, Sadler Gardens", "assessment_type": "RdSAP", "completion_date": "2018-11-26", "inspection_date": "2018-11-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 41, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_u_value": 1.43, "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 40.83, "quantity": "square metres"}, "party_wall_length": {"value": 15.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 510, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 202, "currency": "GBP"}, "hot_water_cost_current": {"value": 270, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 220, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 184, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 65}], "co2_emissions_potential": 2.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 272, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 222, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2631, "impact_of_loft_insulation": -219, "impact_of_cavity_insulation": -1532, "space_heating_existing_dwelling": 3476}, "energy_consumption_current": 493, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 320, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050859851, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S61 3DA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROTHERHAM", "built_form": 2, "created_at": "2018-12-10 15:57:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "30, Pepper Close", "assessment_type": "RdSAP", "completion_date": "2018-12-10", "inspection_date": "2018-12-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.33, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 32.33, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 511, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 451, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2118, "impact_of_loft_insulation": -483, "space_heating_existing_dwelling": 7920}, "energy_consumption_current": 253, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 134, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100030753377, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PE22 0SR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOSTON", "built_form": 2, "created_at": "2018-11-07 09:03:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18118}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "13, Frithville Road", "address_line_2": "Sibsey", "assessment_type": "RdSAP", "completion_date": "2018-11-07", "inspection_date": "2018-11-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 68, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.447, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.561, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.734, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.0, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1712, "space_heating_existing_dwelling": 6028}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 171, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10010686654, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Full secondary glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE1 1DS", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "DERBY", "built_form": 6, "created_at": "2018-11-18 18:10:02.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "Flat 5", "address_line_2": "16a South Street", "assessment_type": "RdSAP", "completion_date": "2018-11-18", "inspection_date": "2018-11-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3.14}, "total_floor_area": 49, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.635, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 3, "wall_insulation_type": 3, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 24.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 24.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.49, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 594, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 334, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 238, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.6, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 438, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 376, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 189, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1033, "space_heating_existing_dwelling": 3589}, "energy_consumption_current": 306, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 314, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 83037083, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HD9 3BN", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HOLMFIRTH", "built_form": 1, "created_at": "2018-07-08 11:57:04.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8066}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "17, Hill", "assessment_type": "RdSAP", "completion_date": "2018-07-08", "inspection_date": "2018-07-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 156, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-07-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 77.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 36.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 77.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 36.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1773, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 132, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 772, "currency": "GBP"}, "hot_water_cost_current": {"value": 257, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 781, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 249, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 274, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 3.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 349, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4179, "impact_of_solid_wall_insulation": -13424, "space_heating_existing_dwelling": 28426}, "energy_consumption_current": 399, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "3.05r03", "energy_consumption_potential": 126, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100080025928, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK42 7AA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 3, "created_at": "2018-04-26 17:10:20", "door_count": 2, "glazed_area": 2, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Manor Close", "address_line_2": "Kempston", "assessment_type": "RdSAP", "completion_date": "2018-04-26", "inspection_date": "2018-04-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 50}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.3, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.3, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.93, "quantity": "square metres"}, "party_wall_length": 2.7, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 519, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 88, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 519, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2230, "impact_of_loft_insulation": -255, "space_heating_existing_dwelling": 9040}, "energy_consumption_current": 77, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 66, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "B", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 14, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 200219836, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW9 5HD", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-08-29 07:12:40.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "2 Patton Studios", "address_line_2": "126 Colindale Avenue", "assessment_type": "RdSAP", "completion_date": "2018-08-29", "inspection_date": "2018-08-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 21, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-08-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 20.7, "quantity": "square metres"}, "party_wall_length": {"value": 16.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 104, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.7, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 22, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 104, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 22, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1625, "space_heating_existing_dwelling": 303}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 187, "environmental_impact_current": 85, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 42014596, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 15% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CH45 1HT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 2, "created_at": "2018-02-28 13:53:03.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Brackenhurst Drive", "assessment_type": "RdSAP", "completion_date": "2018-02-28", "inspection_date": "2018-02-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 123, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-02-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.52, "quantity": "square metres"}, "party_wall_length": {"value": 9.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 61.52, "quantity": "square metres"}, "party_wall_length": {"value": 9.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 15, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 933, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 507, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2294, "impact_of_solid_wall_insulation": -5657, "space_heating_existing_dwelling": 15109}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100110597937, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE24 2SG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLYTH", "built_form": 4, "created_at": "2018-06-01 16:29:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "35, Second Avenue", "assessment_type": "RdSAP", "completion_date": "2018-06-01", "inspection_date": "2018-05-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.33, "quantity": "square metres"}, "party_wall_length": {"value": 16.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 266, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 240, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1737, "space_heating_existing_dwelling": 3408}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 158, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200003981331, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W4 1QG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-02-22 15:03:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Ground Floor Flat", "address_line_2": "26 Thornton Avenue", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-22", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.9, "quantity": "metres"}}, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 24.92, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.75, "quantity": "square metres"}, "party_wall_length": {"value": 4.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 29.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.85, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 562, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 299, "currency": "GBP"}, "hot_water_cost_current": {"value": 74, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 5, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1650, "impact_of_solid_wall_insulation": -3699, "space_heating_existing_dwelling": 9714}, "energy_consumption_current": 288, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 152, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100021497861, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 46% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "UB10 0BE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UXBRIDGE", "built_form": 1, "created_at": "2018-03-12 10:30:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 15028}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "86, Vine Lane", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-10", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 165, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 32.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 27.95, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.95, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 21.82, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "C"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1309, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 136, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 839, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2985, "impact_of_cavity_insulation": -2574, "space_heating_existing_dwelling": 27143}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 130, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070253640, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"access_issues": "true"}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CV31 1EZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEAMINGTON SPA", "built_form": 4, "created_at": "2018-01-15 12:22:57", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15022}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Russell Terrace", "assessment_type": "RdSAP", "completion_date": "2018-01-15", "inspection_date": "2018-01-15", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 201, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-01-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 38, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.98, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.19, "quantity": "square metres"}, "party_wall_length": {"value": 18.860001, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 57.22, "quantity": "square metres"}, "party_wall_length": {"value": 18.860001, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.1, "quantity": "square metres"}, "party_wall_length": {"value": 5.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.83, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 17.92, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2008, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.0, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 169, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1264, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 40, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 419, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}], "co2_emissions_potential": 4.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 109, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3004, "impact_of_loft_insulation": -3023, "impact_of_cavity_insulation": -601, "impact_of_solid_wall_insulation": -3849, "space_heating_existing_dwelling": 34562}, "energy_consumption_current": 304, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "2.0.x", "energy_consumption_potential": 158, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 150052, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS4 1SW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2018-02-26 16:53:42.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16848}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "123, Wallingford Road", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.97, "quantity": "square metres"}, "party_wall_length": {"value": 7.08, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 43.97, "quantity": "square metres"}, "party_wall_length": {"value": 7.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 434, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 375, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2096, "impact_of_loft_insulation": -215, "space_heating_existing_dwelling": 6653}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 75, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100051340030, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HX1 2TN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HALIFAX", "built_form": 6, "created_at": "2018-06-21 11:21:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "storage_heaters": [{"index_number": 230002, "number_of_heaters": 1, "high_heat_retention": "true"}], "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 113, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Enclosed-mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "33, Stirling Street", "assessment_type": "RdSAP", "completion_date": "2018-06-21", "inspection_date": "2018-06-21", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 56, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 35, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 366, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 366, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "insulated_door_u_value": 3, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1800, "impact_of_solid_wall_insulation": -300, "space_heating_existing_dwelling": 5288}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 100, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 235044280, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LN2 4WJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LINCOLN", "built_form": 4, "created_at": "2018-02-28 11:50:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16138}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "118, Carlton Boulevard", "assessment_type": "RdSAP", "completion_date": "2018-02-28", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 130, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-02-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.35, "quantity": "square metres"}, "party_wall_length": {"value": 15.88, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 43.35, "quantity": "square metres"}, "party_wall_length": {"value": 15.88, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.92, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 43.35, "quantity": "square metres"}, "party_wall_length": {"value": 15.88, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 554, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 554, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 2.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2192, "impact_of_loft_insulation": -309, "space_heating_existing_dwelling": 9861}, "energy_consumption_current": 142, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 99, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 10014335399, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BA14 8GD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "TROWBRIDGE", "built_form": 3, "created_at": "2018-07-17 19:57:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 191, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "5 Beaufort Mansions", "address_line_2": "55-57, Stallard Street", "assessment_type": "RdSAP", "completion_date": "2018-07-17", "inspection_date": "2018-07-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.32, "quantity": "metres"}}, "total_floor_area": 24, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-07-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 700, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.4596, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 23.53, "quantity": "square metres"}, "party_wall_length": {"value": 6.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 120, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 124, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 124, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1326, "space_heating_existing_dwelling": 641}, "energy_consumption_current": 300, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 272, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100091589913, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SS15 6SB", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BASILDON", "built_form": 4, "created_at": "2018-07-11 23:38:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "65, Helmore Court", "address_line_2": "Helmores", "assessment_type": "RdSAP", "completion_date": "2018-07-11", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51, "quantity": "square metres"}, "party_wall_length": {"value": 18.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 301, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 243, "currency": "GBP"}, "hot_water_cost_current": {"value": 296, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 83}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 85}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.8, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 83}}], "hot_water_cost_potential": {"value": 261, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1837, "impact_of_cavity_insulation": -722, "space_heating_existing_dwelling": 3782}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 209, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100100375706, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA5 9BJ", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "SWANSEA", "built_form": 2, "created_at": "2018-06-22 10:21:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2303, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "54, St. Clears Place", "address_line_2": "Penlan", "assessment_type": "RdSAP", "completion_date": "2018-06-22", "inspection_date": "2018-04-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.4, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 264, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 264, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 118, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2095, "space_heating_existing_dwelling": 3128}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 166, "environmental_impact_current": 98, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 98, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10070602735, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN34 1SG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HASTINGS", "built_form": 2, "created_at": "2018-12-21 11:50:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 10", "address_line_2": "43 Earl Street", "assessment_type": "RdSAP", "completion_date": "2018-12-21", "inspection_date": "2018-09-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.0, "quantity": "metres"}}, "total_floor_area": 79, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-12-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 1.0, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78.5, "quantity": "square metres"}, "party_wall_length": {"value": 16.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 194, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 83, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 194, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2095, "space_heating_existing_dwelling": 1679}, "energy_consumption_current": 94, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 94, "environmental_impact_current": 86, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "B", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 17, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10034805694, "roofs": [{"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NR11 7AA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "NORWICH", "built_form": 1, "created_at": "2018-09-03 18:46:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15926}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "The Hoppits", "address_line_2": "The Green", "address_line_3": "Aldborough", "assessment_type": "RdSAP", "completion_date": "2018-09-03", "inspection_date": "2018-09-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-09-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 35.8, "insulation": 6, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "ND"}, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 696, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 124, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 423, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 204, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 98, "environmental_impact_rating": 89}], "co2_emissions_potential": 1.1, "energy_rating_potential": 98, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2740, "space_heating_existing_dwelling": 16272}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": -10, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010111710, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CH64 0XQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NESTON", "built_form": 1, "created_at": "2018-06-14 13:39:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Foxglove Way", "address_line_2": "Little Neston", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 128, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 6, "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 11.76, "quantity": "square metres"}, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": {"value": 9.86, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.98, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 53.98, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 762, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 723, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2974, "impact_of_loft_insulation": -79, "space_heating_existing_dwelling": 12920}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 137, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100865231, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL11 3PJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WREXHAM", "built_form": 1, "created_at": "2018-07-24 16:14:23.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15451}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Fferm Llidiart Werdd", "address_line_2": "Coedpoeth", "assessment_type": "RdSAP", "completion_date": "2018-07-24", "inspection_date": "2018-07-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 43.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.13, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 527, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 490, "currency": "GBP"}, "hot_water_cost_current": {"value": 149, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3220, "impact_of_loft_insulation": -75, "space_heating_existing_dwelling": 9424}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 125, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10010171124, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HX3 9HX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "HALIFAX", "built_form": 4, "created_at": "2018-02-27 22:55:15.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Jubilee Terrace", "assessment_type": "RdSAP", "completion_date": "2018-02-27", "inspection_date": "2018-02-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-02-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 17.92, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.33, "quantity": "square metres"}, "party_wall_length": {"value": 13.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 26.33, "quantity": "square metres"}, "party_wall_length": {"value": 13.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.29, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 802, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2336, "impact_of_loft_insulation": -771, "impact_of_solid_wall_insulation": -1115, "space_heating_existing_dwelling": 13730}, "energy_consumption_current": 337, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 125, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 14048010, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG40 1TY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOKINGHAM", "built_form": 2, "created_at": "2018-05-08 11:54:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15023}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "1, Coronation Square", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 5.97, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.37, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 348, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.4, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 47, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1546, "space_heating_existing_dwelling": 5227}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 55, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 200001785462, "roofs": [{"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, with additional insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP31 2QY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BURY ST. EDMUNDS", "built_form": 1, "created_at": "2018-05-14 12:02:08", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15930}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Shrub Wood Cottage", "address_line_2": "East Barton, Great Barton", "assessment_type": "RdSAP", "completion_date": "2018-05-14", "inspection_date": "2018-05-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 223, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-05-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 51.4, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "Y", "construction_age_band": "A", "roof_insulation_thickness": "250mm"}, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.97, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 28.23, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "Y", "construction_age_band": "E", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.14, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.95, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 28.41, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "Y", "construction_age_band": "E", "roof_insulation_thickness": "150mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 28.83, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 793, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.6, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 742, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}], "co2_emissions_potential": 4.9, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 105, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2919, "impact_of_loft_insulation": -546, "space_heating_existing_dwelling": 17354}, "energy_consumption_current": 126, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 34, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 34} +{"uprn": 200004179386, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 27% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CB5 8LF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 4, "created_at": "2018-01-30 22:20:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 17511}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "145, Stanley Road", "assessment_type": "RdSAP", "completion_date": "2018-01-30", "inspection_date": "2018-01-30", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.99, "quantity": "square metres"}, "party_wall_length": {"value": 6.81, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 26.99, "quantity": "square metres"}, "party_wall_length": {"value": 6.81, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.46, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.84, "quantity": "square metres"}, "party_wall_length": 6.81, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 364, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1776, "impact_of_loft_insulation": -1012, "impact_of_solid_wall_insulation": -2437, "space_heating_existing_dwelling": 8943}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 74, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 207178296, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "N9 9AL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-03-27 13:43:19.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "305, Haselbury Road", "assessment_type": "RdSAP", "completion_date": "2018-03-27", "inspection_date": "2018-03-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6.07, "quantity": "metres"}}, "total_floor_area": 74, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-03-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.8108, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 73.57, "quantity": "square metres"}, "party_wall_length": {"value": 11.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 318, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 187, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 144, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2754, "impact_of_solid_wall_insulation": -2816, "space_heating_existing_dwelling": 4272}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 111, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10002660604, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN5 7QY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WADHURST", "built_form": 2, "created_at": "2018-01-25 07:41:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15016}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "13, The Warren", "address_line_2": "Ticehurst", "assessment_type": "RdSAP", "completion_date": "2018-01-25", "inspection_date": "2018-01-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 50, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.53, "quantity": "square metres"}, "party_wall_length": {"value": 7.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.91, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 24.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 339, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 321, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2357, "impact_of_loft_insulation": -116, "space_heating_existing_dwelling": 5035}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 78, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10000065587, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [9]}, "lighting": {"description": "Low energy lighting in 46% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TN17 4BG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CRANBROOK", "built_form": 1, "created_at": "2018-05-28 07:09:53", "door_count": 3, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 645}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.5, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Windmill Cottage", "address_line_2": "Goddards Green Road", "address_line_3": "Benenden", "assessment_type": "RdSAP", "completion_date": "2018-05-28", "inspection_date": "2018-05-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 149, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-05-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.75, "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.04, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.39, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 63.39, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 10.34, "insulation": 0, "roof_room_connected": "Y", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.04, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1571, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 964, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 394, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 201, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.3, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 82}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 393, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2991, "impact_of_loft_insulation": -164, "impact_of_solid_wall_insulation": -6417, "space_heating_existing_dwelling": 23222}, "energy_consumption_current": 337, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 76, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 24, "current_energy_efficiency_band": "E", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100060516397, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, with internal insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 26% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SO40 7PS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-09-25 09:03:04.000000", "door_count": 4, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16397}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "26, Reynolds Dale", "address_line_2": "Ashurst", "assessment_type": "RdSAP", "completion_date": "2018-09-25", "inspection_date": "2018-09-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 120, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-09-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 10.65, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 9.69}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 47.07, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.24, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 26, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 809, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 772, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.3, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2963, "impact_of_loft_insulation": -31, "space_heating_existing_dwelling": 11809}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "3.07r02", "energy_consumption_potential": 156, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 503144, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS34 5EH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2018-06-12 13:43:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "15, Lee Close", "address_line_2": "Patchway", "assessment_type": "RdSAP", "completion_date": "2018-06-12", "inspection_date": "2018-06-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 46, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 354, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 284, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.4, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1640, "space_heating_existing_dwelling": 5392}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 46, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110217678, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CA13 0TE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COCKERMOUTH", "built_form": 2, "created_at": "2018-03-15 11:09:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, High Brigham", "address_line_2": "Brigham", "assessment_type": "RdSAP", "completion_date": "2018-03-15", "inspection_date": "2018-03-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 317, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.33, "quantity": "square metres"}, "party_wall_length": {"value": 7.25, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 46.33, "quantity": "square metres"}, "party_wall_length": {"value": 7.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 828, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 628, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2335, "impact_of_cavity_insulation": -2862, "space_heating_existing_dwelling": 14252}, "energy_consumption_current": 293, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 152, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100020229327, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DA8 1AP", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ERITH", "built_form": 2, "created_at": "2018-08-07 10:56:39.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "92, Galleon Close", "assessment_type": "RdSAP", "completion_date": "2018-08-07", "inspection_date": "2018-06-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "Y", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.0, "quantity": "metres"}}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-08-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.0, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 695, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 407, "currency": "GBP"}, "hot_water_cost_current": {"value": 246, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 176, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 218, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 46}], "co2_emissions_potential": 3.4, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 305, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 233, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1780, "space_heating_existing_dwelling": 7303}, "energy_consumption_current": 654, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 440, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 46, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 111, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100022291418, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW13 0AJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-13 15:35:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8788}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "63, Cleveland Gardens", "assessment_type": "RdSAP", "completion_date": "2018-09-13", "inspection_date": "2018-09-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 143, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 3, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 3}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 210, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.1, "quantity": "square metres"}, "party_wall_length": {"value": 24.29, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 69.51, "quantity": "square metres"}, "party_wall_length": {"value": 24.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1108, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 163, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 637, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 286, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3211, "impact_of_solid_wall_insulation": -4008, "space_heating_existing_dwelling": 15487}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "3.07r02", "energy_consumption_potential": 105, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 23027251, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "OL10 3EW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HEYWOOD", "built_form": 3, "created_at": "2018-01-05 13:37:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10047}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "85, Wilton Street", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 35.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 669, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 417, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 218, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 255, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2017, "impact_of_solid_wall_insulation": -4725, "space_heating_existing_dwelling": 12002}, "energy_consumption_current": 305, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 110, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200001329802, "roofs": [{"description": {"value": "Pitched, 400 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST18 0RA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "STAFFORD", "built_form": 1, "created_at": "2018-02-12 12:12:31.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17137}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Toll House", "address_line_2": "Tolldish Lane", "address_line_3": "Great Haywood", "assessment_type": "RdSAP", "completion_date": "2018-02-12", "inspection_date": "2018-02-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 165, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-02-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, smokeless fuel", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.23, "quantity": "metres"}, "total_floor_area": {"value": 55.08, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 23.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.07, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 24.07, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.05, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.85, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1262, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 766, "currency": "GBP"}, "hot_water_cost_current": {"value": 148, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 59}], "co2_emissions_potential": 6.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 39}}], "hot_water_cost_potential": {"value": 120, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3508, "impact_of_loft_insulation": -1348, "impact_of_cavity_insulation": -1679, "impact_of_solid_wall_insulation": -6262, "space_heating_existing_dwelling": 23120}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 126, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "E", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 26} +{"uprn": 100030531697, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV13 0AG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, "post_town": "NUNEATON", "built_form": 2, "created_at": "2018-09-28 12:38:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 33, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 33, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 633, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, coal", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Main Street", "address_line_2": "Sutton Cheney", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-07-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.1, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 41.1, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 716, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.9, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 595, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 29}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 32}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 36}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 41}], "co2_emissions_potential": 6.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2822, "space_heating_existing_dwelling": 10374}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 158, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 41, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 108, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200004752617, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO30 1YG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 4, "created_at": "2018-01-05 10:08:58.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17983}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "124, Brecksfield", "address_line_2": "Skelton", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.42, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 39.12, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.42, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 467, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 434, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2018, "space_heating_existing_dwelling": 7969}, "energy_consumption_current": 202, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 102, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10008037107, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 81% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE13 8BH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BURTON-ON-TRENT", "built_form": 1, "created_at": "2018-04-27 17:41:40.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17107}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Kennels", "address_line_2": "Smiths Hills", "address_line_3": "Dunstall", "assessment_type": "RdSAP", "completion_date": "2018-04-27", "inspection_date": "2018-04-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 149, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-04-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.37, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 49.87, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.71, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 81, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1008, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.8, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 643, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 100, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 49}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2976, "impact_of_cavity_insulation": -2787, "impact_of_solid_wall_insulation": -2336, "space_heating_existing_dwelling": 22442}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 40, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 200002836545, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CW10 0RA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MIDDLEWICH", "built_form": 2, "created_at": "2018-09-19 13:45:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16520}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1a, Steele Road", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.7, "quantity": "square metres"}, "party_wall_length": {"value": 4.76, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 41.7, "quantity": "square metres"}, "party_wall_length": {"value": 4.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.97, "quantity": "square metres"}, "party_wall_length": {"value": 3.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 664, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 131, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 185, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 182, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 204, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2882, "impact_of_loft_insulation": -335, "space_heating_existing_dwelling": 9329}, "energy_consumption_current": 279, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100070688453, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV2 1EU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 2, "created_at": "2018-05-14 16:22:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17663}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "76, Petitor Crescent", "assessment_type": "RdSAP", "completion_date": "2018-05-14", "inspection_date": "2018-05-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-05-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.66, "quantity": "square metres"}, "party_wall_length": {"value": 5.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.66, "quantity": "square metres"}, "party_wall_length": {"value": 5.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.2, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.28, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.8, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 497, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 449, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2086, "impact_of_loft_insulation": -574, "space_heating_existing_dwelling": 8484}, "energy_consumption_current": 171, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 87, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 6004138, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E2 7HJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-04 17:17:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15755}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 27", "address_line_2": "Abingdon House", "address_line_3": "Boundary Street", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.89}, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.8338, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 92.28, "quantity": "square metres"}, "party_wall_length": {"value": 17.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 176, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 168, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2736, "impact_of_solid_wall_insulation": -3678, "space_heating_existing_dwelling": 6907}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.06r03", "energy_consumption_potential": 84, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 30, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 30} +{"uprn": 10032961019, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ9 6BP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "TOTNES", "built_form": 2, "created_at": "2018-02-27 07:36:39.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 139, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Eastview", "address_line_2": "Broadhempston", "assessment_type": "RdSAP", "completion_date": "2018-02-27", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-02-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 5, "room_height": 1, "double_glazed": "N", "glazed_perimeter": 5}, {"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.58, "quantity": "square metres"}, "party_wall_length": {"value": 4.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.13, "quantity": "metres"}, "total_floor_area": {"value": 56.58, "quantity": "square metres"}, "party_wall_length": {"value": 4.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1190, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 21, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 391, "currency": "GBP"}, "hot_water_cost_current": {"value": 213, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 386, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 32}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 35}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 35}, {"sequence": 4, "typical_saving": {"value": 186, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 5, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 37}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 94}}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2961, "impact_of_solid_wall_insulation": -5936, "space_heating_existing_dwelling": 17507}, "energy_consumption_current": 367, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 76, "environmental_impact_current": 19, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "F", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 97, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 41123628, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "L31 2PL", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-01-30 17:31:14.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "47 Cornmill Lodge", "address_line_2": "Liverpool Road North", "assessment_type": "RdSAP", "completion_date": "2018-01-30", "inspection_date": "2018-01-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 42, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-01-30", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 41.63, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 152, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 135, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 101, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1423, "space_heating_existing_dwelling": 1633}, "energy_consumption_current": 258, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 217, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050538888, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO31 9EL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 2, "created_at": "2018-02-06 13:34:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "47, Brockfield Park Drive", "assessment_type": "RdSAP", "completion_date": "2018-02-06", "inspection_date": "2018-02-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.28, "quantity": "square metres"}, "party_wall_length": {"value": 8.66, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.46, "quantity": "square metres"}, "party_wall_length": {"value": 5.94, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 524, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 475, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2318, "space_heating_existing_dwelling": 8189}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 125, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100120587682, "roofs": [{"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B60 1NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BROMSGROVE", "built_form": 2, "created_at": "2018-05-17 10:31:35.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8204}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Finstall House", "address_line_2": "Alcester Road", "address_line_3": "Tutnall", "assessment_type": "RdSAP", "completion_date": "2018-05-17", "inspection_date": "2018-05-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 365, "transaction_type": 11, "conservatory_type": 2, "heated_room_count": 12, "pvc_window_frames": "false", "registration_date": "2018-05-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 110.84, "quantity": "square metres"}, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.03, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 32.35, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 110.84, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 46.08, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.19, "quantity": "metres"}, "total_floor_area": {"value": 110.84, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 53.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 12, "heating_cost_current": {"value": 1824, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 16, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 138, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1279, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 478, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 72}], "co2_emissions_potential": 8.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 138, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3088, "impact_of_solid_wall_insulation": -11329, "space_heating_existing_dwelling": 42371}, "energy_consumption_current": 168, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 73, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 100, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 100} +{"uprn": 100061382805, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "GU4 7YT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "GUILDFORD", "built_form": 4, "created_at": "2018-08-09 19:19:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2704, "main_heating_category": 11, "main_heating_fraction": 1, "sap_main_heating_code": 701, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric ceiling heating", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "26, Bradfield Close", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 36, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.71, "quantity": "square metres"}, "party_wall_length": {"value": 19.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 131, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 244, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.7, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 321, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 281, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1526, "space_heating_existing_dwelling": 2837}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 274, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100012774627, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SK12 1TE", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "STOCKPORT", "built_form": 1, "created_at": "2018-03-12 16:44:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "18, Shrigley Road North", "address_line_2": "Poynton", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 90.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 39.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1218, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 123, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 697, "currency": "GBP"}, "hot_water_cost_current": {"value": 219, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 191, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 200, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 8, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 89}, {"sequence": 3, "typical_saving": {"value": 101, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 354, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3550, "impact_of_loft_insulation": -1899, "impact_of_cavity_insulation": -2799, "space_heating_existing_dwelling": 16155}, "energy_consumption_current": 445, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "3.04r01", "energy_consumption_potential": 161, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 48041450, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW20 8TP", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-04-24 22:50:16.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6, Burvill Court", "address_line_2": "21, Langham Road", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 14, "quantity": "metres"}}, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 33.6, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 51.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 207, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 152, "currency": "GBP"}, "hot_water_cost_current": {"value": 546, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 48}}], "hot_water_cost_potential": {"value": 190, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5787, "impact_of_cavity_insulation": -972, "space_heating_existing_dwelling": 2112}, "energy_consumption_current": 484, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "2.0.x", "energy_consumption_potential": 225, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 82, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 90088379, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 10% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "DY2 8BH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DUDLEY", "built_form": 4, "created_at": "2018-01-10 12:42:25.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "20, Heathcliff Road", "assessment_type": "RdSAP", "completion_date": "2018-01-10", "inspection_date": "2018-01-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-01-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.06, "quantity": "square metres"}, "party_wall_length": {"value": 11.56, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.34, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 40.06, "quantity": "square metres"}, "party_wall_length": {"value": 11.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.34, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 432, "currency": "GBP"}, "insulated_door_count": 3, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 410, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "insulated_door_u_value": 1.6, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2067, "space_heating_existing_dwelling": 7142}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 88, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100100848028, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 7% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CF64 5SZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PENARTH", "built_form": 1, "created_at": "2018-03-26 14:08:12.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15935}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "14, Somerset View", "address_line_2": "Sully", "assessment_type": "RdSAP", "completion_date": "2018-03-26", "inspection_date": "2018-03-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 152, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-03-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 134.04, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 46.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 7, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1074, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 162, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 776, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 142, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": 65, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 153, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3369, "impact_of_loft_insulation": -689, "impact_of_cavity_insulation": -2536, "space_heating_existing_dwelling": 17077}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "3.04r01", "energy_consumption_potential": 123, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10008637718, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU7 3GR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 3, "created_at": "2018-08-23 09:46:58.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10071}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23 Markeaton Park", "address_line_2": "Kingswood", "assessment_type": "RdSAP", "completion_date": "2018-08-23", "inspection_date": "2018-08-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 29.88, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 317, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 291, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.5, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1971, "space_heating_existing_dwelling": 4612}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 47, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100040651261, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DT3 4EQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEYMOUTH", "built_form": 4, "created_at": "2018-05-30 10:42:48.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9222}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "14, Higher End", "address_line_2": "Chickerell", "assessment_type": "RdSAP", "completion_date": "2018-05-30", "inspection_date": "2018-05-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.85, "quantity": "square metres"}, "party_wall_length": {"value": 15.64, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 268, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 202, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1651, "impact_of_cavity_insulation": -577, "space_heating_existing_dwelling": 3043}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 137, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL4 6HL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 4, "created_at": "2018-06-18 11:15:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17943}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Basement flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Basement Flat", "address_line_2": "6 Evelyn Place", "assessment_type": "RdSAP", "completion_date": "2018-06-18", "inspection_date": "2018-06-13", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.36, "quantity": "square metres"}, "party_wall_length": {"value": 15.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23, "quantity": "square metres"}, "party_wall_length": 5.9, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 140, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.92, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 479, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 288, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1973, "impact_of_solid_wall_insulation": -2695, "space_heating_existing_dwelling": 8203}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 119, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100010361043, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BB12 0RE", "hot_water": {"description": "No system present: electric immersion assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BURNLEY", "built_form": 4, "created_at": "2018-08-09 23:15:27.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 999, "water_heating_fuel": 0, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "No system present: electric heaters assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "11, Willow Street", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-08-09", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 126, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "true", "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 20.33, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.51, "quantity": "square metres"}, "party_wall_length": {"value": 19.24, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.97, "quantity": "metres"}, "total_floor_area": {"value": 46.46, "quantity": "square metres"}, "party_wall_length": {"value": 19.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.47, "quantity": "square metres"}, "party_wall_length": {"value": 3.89, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 4197, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 16, "energy_rating_average": 60, "energy_rating_current": 1, "lighting_cost_current": {"value": 156, "currency": "GBP"}, "main_heating_controls": [{"description": "None", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1840, "currency": "GBP"}, "hot_water_cost_current": {"value": 593, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 1, "environmental_impact_rating": 16}, {"sequence": 2, "typical_saving": {"value": 406, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 4, "environmental_impact_rating": 19}, {"sequence": 3, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 6, "environmental_impact_rating": 20}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 6, "environmental_impact_rating": 21}, {"sequence": 5, "typical_saving": {"value": 2190, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 25}, {"sequence": 6, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 27}, {"sequence": 7, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 30}], "co2_emissions_potential": 11, "energy_rating_potential": 57, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 1, "environmental_impact_rating": 16}, {"sequence": 2, "typical_saving": {"value": 2763, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 93}, {"sequence": 3, "typical_saving": {"value": 2418, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 50, "environmental_impact_rating": 55}], "hot_water_cost_potential": {"value": 118, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3584, "impact_of_loft_insulation": -3577, "impact_of_cavity_insulation": -654, "impact_of_solid_wall_insulation": -2557, "space_heating_existing_dwelling": 25357}, "energy_consumption_current": 729, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 511, "environmental_impact_current": 15, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "G", "environmental_impact_potential": 30, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 123, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060599630, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO23 9LH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WINCHESTER", "built_form": 4, "created_at": "2018-03-11 23:06:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Colebrook Street", "assessment_type": "RdSAP", "completion_date": "2018-03-11", "inspection_date": "2018-03-09", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.87, "quantity": "square metres"}, "party_wall_length": {"value": 14.66, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 33.87, "quantity": "square metres"}, "party_wall_length": {"value": 14.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.58, "quantity": "square metres"}, "party_wall_length": {"value": 2.85, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.86, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 8.58, "quantity": "square metres"}, "party_wall_length": {"value": 2.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1340, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 31, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 307, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 70, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 383, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 25}, {"sequence": 2, "typical_saving": {"value": 234, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 34}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 36}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 37}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 37}, {"sequence": 6, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 38}, {"sequence": 7, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 8, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a31,600 - \u00a32,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 45}, {"sequence": 9, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 49}, {"sequence": 10, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 53}, {"sequence": 11, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 333, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 287, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2163, "impact_of_loft_insulation": -4724, "impact_of_solid_wall_insulation": -2884, "space_heating_existing_dwelling": 16412}, "energy_consumption_current": 693, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 57, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 193, "environmental_impact_current": 14, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 122, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200001474945, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN7 3JF", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NORTHAMPTON", "built_form": 2, "created_at": "2018-07-19 20:12:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Fogg Cottage", "address_line_2": "Banbury Lane", "address_line_3": "Rothersthorpe", "assessment_type": "RdSAP", "completion_date": "2018-07-19", "inspection_date": "2018-07-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-07-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.32, "quantity": "square metres"}, "party_wall_length": {"value": 8.31, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.93, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 27.51, "quantity": "square metres"}, "party_wall_length": {"value": 4.71, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 603, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 338, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 241, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 635, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 121, "environmental_impact_rating": 105}], "co2_emissions_potential": -0.5, "energy_rating_potential": 121, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 451, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 388, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1074, "space_heating_existing_dwelling": 3643}, "energy_consumption_current": 289, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": -54, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 105, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100031514887, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG3 4PF", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-07-12 10:54:08.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 30, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 30, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2306, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Aster Road", "assessment_type": "RdSAP", "completion_date": "2018-07-12", "inspection_date": "2018-03-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-07-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Charging system linked to use of community heating, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 420, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 107}], "co2_emissions_potential": 2.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2440, "impact_of_loft_insulation": -316, "space_heating_existing_dwelling": 6147}, "energy_consumption_current": 169, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 91, "environmental_impact_current": 98, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 107, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100062500461, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SM7 3DL", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BANSTEAD", "built_form": 3, "created_at": "2018-09-30 14:06:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Flat 7 The Mews Parkside Nursing Home", "address_line_2": "Park Road", "assessment_type": "RdSAP", "completion_date": "2018-09-30", "inspection_date": "2018-09-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 33, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 11.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 340, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 27, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 250, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.4, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1703, "impact_of_loft_insulation": -193, "impact_of_solid_wall_insulation": -1188, "space_heating_existing_dwelling": 4571}, "energy_consumption_current": 357, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 70, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100630170, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SA12 7TA", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "PORT TALBOT", "built_form": 2, "created_at": "2018-05-02 09:08:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1843}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Handel Avenue", "assessment_type": "RdSAP", "completion_date": "2018-05-02", "inspection_date": "2018-05-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.04, "quantity": "square metres"}, "party_wall_length": {"value": 5.85, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 44.54, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.16, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 662, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 484, "currency": "GBP"}, "hot_water_cost_current": {"value": 256, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 210, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4052, "space_heating_existing_dwelling": 8785}, "energy_consumption_current": 300, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 102, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 22112335, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BN2 8EZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "BRIGHTON", "built_form": 5, "created_at": "2018-07-04 08:49:05.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "10, Westbrook", "address_line_2": "Lustrells Vale", "assessment_type": "RdSAP", "completion_date": "2018-07-04", "inspection_date": "2018-07-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.95, "quantity": "metres"}}, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 78.48, "quantity": "square metres"}, "party_wall_length": {"value": 17.93, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 375, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 206, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 88, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 157, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2103, "impact_of_cavity_insulation": -1592, "space_heating_existing_dwelling": 4146}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 190, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 90057748, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DY6 0LA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KINGSWINFORD", "built_form": 4, "created_at": "2018-07-06 20:19:30.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "20, Blaze Hill Road", "assessment_type": "RdSAP", "completion_date": "2018-07-06", "inspection_date": "2018-07-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.63, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.96, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 29.63, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.96, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.61, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 12.61, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 524, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 467, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "2,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2166, "space_heating_existing_dwelling": 7313}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 93, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100060330563, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 55% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO30 4AE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-09-29 23:42:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "17, Waters Edge", "address_line_2": "Hedge End", "assessment_type": "RdSAP", "completion_date": "2018-09-29", "inspection_date": "2018-09-05", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7, "wall_dry_lined": "N", "wall_thickness": 235, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.37, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 21.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.18, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 18.18, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.82, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 615, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 579, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2706, "impact_of_loft_insulation": -1394, "impact_of_solid_wall_insulation": -360, "space_heating_existing_dwelling": 10954}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 143, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100091182162, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR33 9LW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LOWESTOFT", "built_form": 4, "created_at": "2018-09-28 12:03:08.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "49, Victoria Road", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-09-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.08, "quantity": "square metres"}, "party_wall_length": {"value": 14.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 36.96, "quantity": "square metres"}, "party_wall_length": {"value": 14.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 409, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 306, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 81}, {"sequence": 4, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2026, "impact_of_solid_wall_insulation": -1518, "space_heating_existing_dwelling": 6715}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 43, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100091365258, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP9 1LG", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "IPSWICH", "built_form": 1, "created_at": "2018-05-22 15:15:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 633, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Conifers", "address_line_2": "Shotley", "assessment_type": "RdSAP", "completion_date": "2018-05-22", "inspection_date": "2018-05-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 214, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-05-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 47.85, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "Y", "construction_age_band": "D", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 89, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 40.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 29.37, "quantity": "square metres"}, "insulation": 5, "roof_room_connected": "Y", "construction_age_band": "E", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 2017, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 16.0, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1366, "currency": "GBP"}, "hot_water_cost_current": {"value": 283, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 134, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 29}, {"sequence": 2, "typical_saving": {"value": 233, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 34}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 35}, {"sequence": 4, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "4,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 42}, {"sequence": 5, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 44}, {"sequence": 6, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 47}], "co2_emissions_potential": 9.7, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 113, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 181, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 514, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 310, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 130, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3722, "impact_of_loft_insulation": -1883, "impact_of_cavity_insulation": -1902, "space_heating_existing_dwelling": 28178}, "energy_consumption_current": 440, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 264, "environmental_impact_current": 27, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "E", "environmental_impact_potential": 47, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100010132824, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 12% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "WA16 7HD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KNUTSFORD", "built_form": 1, "created_at": "2018-06-14 06:19:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17115}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "17, Carlisle Close", "address_line_2": "Mobberley", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-13", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 147, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 25.17, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.47, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 12, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 927, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 155, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 860, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}], "co2_emissions_potential": 4.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2062, "impact_of_loft_insulation": -804, "space_heating_existing_dwelling": 18403}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 153, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 36007446, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 54% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LA14 1NG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARROW-IN-FURNESS", "built_form": 4, "created_at": "2018-03-12 22:19:37.000000", "door_count": 2, "glazed_area": 1, "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Nelson Street", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 160, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.99, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.63, "quantity": "square metres"}, "party_wall_length": {"value": 16.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 43.63, "quantity": "square metres"}, "party_wall_length": {"value": 16.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.08, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 43.63, "quantity": "square metres"}, "party_wall_length": {"value": 16.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.78, "quantity": "square metres"}, "party_wall_length": {"value": 4.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 14.78, "quantity": "square metres"}, "party_wall_length": {"value": 4.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1117, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 880, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 75, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 3.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 87, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 109, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2325, "impact_of_cavity_insulation": -1247, "impact_of_solid_wall_insulation": -2910, "space_heating_existing_dwelling": 16972}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 129, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090626424, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CO7 8AJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "COLCHESTER", "built_form": 1, "created_at": "2018-01-18 22:41:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15342}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "231, Wivenhoe Road", "address_line_2": "Alresford", "assessment_type": "RdSAP", "completion_date": "2018-01-18", "inspection_date": "2018-01-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-01-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.35, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.05, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.15, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 604, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 420, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2967, "space_heating_existing_dwelling": 12970}, "energy_consumption_current": 242, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 108, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 207009655, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "N18 1HR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 5, "created_at": "2018-02-15 14:49:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17644}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 13 Dover House", "address_line_2": "Bolton Road", "assessment_type": "RdSAP", "completion_date": "2018-02-15", "inspection_date": "2018-02-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 5.26}, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.7298, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 240, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "total_floor_area": {"value": 71.13, "quantity": "square metres"}, "party_wall_length": {"value": 9.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 420, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 424, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.4, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1764, "space_heating_existing_dwelling": 6874}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 188, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100062462499, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 37% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG25 2BL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BASINGSTOKE", "built_form": 1, "created_at": "2018-06-20 14:37:20.000000", "door_count": 4, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17541}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Grayshott", "address_line_2": "Church Road", "address_line_3": "North Waltham", "assessment_type": "RdSAP", "completion_date": "2018-06-20", "inspection_date": "2018-06-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 275, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-06-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 111.63, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 39.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 103.54, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 44.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 323, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 37, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1795, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 17.0, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 190, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1082, "currency": "GBP"}, "hot_water_cost_current": {"value": 296, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 61, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 462, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 9, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 10, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}, {"sequence": 11, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 74}], "co2_emissions_potential": 6.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 118, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 47, "environmental_impact_rating": 40}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 6999, "impact_of_cavity_insulation": -1595, "impact_of_solid_wall_insulation": -10645, "space_heating_existing_dwelling": 40461}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "2.0.x", "energy_consumption_potential": 67, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10003000506, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA4 6LG", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "RUISLIP", "built_form": 2, "created_at": "2018-07-23 20:56:52.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "86, Carmichael Close", "assessment_type": "RdSAP", "completion_date": "2018-07-23", "inspection_date": "2018-07-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.382, "quantity": "metres"}, "total_floor_area": {"value": 86.96, "quantity": "square metres"}, "party_wall_length": {"value": 11.535, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 337, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 212, "currency": "GBP"}, "hot_water_cost_current": {"value": 225, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 278, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 216, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 195, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2031, "space_heating_existing_dwelling": 2276}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 168, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100030550574, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG13 0AY", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2018-09-13 07:58:02.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "30, Walnut Road", "address_line_2": "Bottesford", "assessment_type": "RdSAP", "completion_date": "2018-09-13", "inspection_date": "2018-09-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2018-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.38, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 567, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 505, "currency": "GBP"}, "hot_water_cost_current": {"value": 330, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 137, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2233, "space_heating_existing_dwelling": 9413}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 110, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100120381066, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"narrow_cavities": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL53 7PB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHELTENHAM", "built_form": 2, "created_at": "2018-06-16 15:58:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Ewlyn Road", "assessment_type": "RdSAP", "completion_date": "2018-06-16", "inspection_date": "2018-06-15", "extensions_count": 3, "measurement_type": 2, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 7.97, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 40.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18, "quantity": "square metres"}, "party_wall_length": {"value": 5.75, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 18, "quantity": "square metres"}, "party_wall_length": {"value": 5.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.12, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.11, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1427, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.8, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 782, "currency": "GBP"}, "hot_water_cost_current": {"value": 235, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 70, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 236, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 47}, {"sequence": 6, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 50}, {"sequence": 7, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 9, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 124, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 130, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 376, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3336, "impact_of_loft_insulation": -1712, "impact_of_cavity_insulation": -3710, "space_heating_existing_dwelling": 20007}, "energy_consumption_current": 434, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 70, "calculation_software_version": "3.05r03", "energy_consumption_potential": 164, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 77164485, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "M12 4PB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-03-12 19:02:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17991}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50, Stainer Street", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-08", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.803, "wall_dry_lined": "Y", "wall_thickness": 270, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.815, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.172, "quantity": "square metres"}, "party_wall_length": {"value": 14.099, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.719, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.753, "quantity": "metres"}, "total_floor_area": {"value": 26.015, "quantity": "square metres"}, "party_wall_length": {"value": 13.476, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.723, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.107, "quantity": "square metres"}, "party_wall_length": {"value": 2.25, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.897, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.008, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.007, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 488, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 415, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a385", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1895, "impact_of_loft_insulation": -435, "impact_of_cavity_insulation": -835, "impact_of_solid_wall_insulation": -517, "space_heating_existing_dwelling": 8461}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 118, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100100317629, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LD3 8DB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRECON", "built_form": 2, "created_at": "2018-06-21 14:21:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "27, Penyfan Road", "assessment_type": "RdSAP", "completion_date": "2018-06-21", "inspection_date": "2018-06-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 5.29, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": 2.3}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.15, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 43, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 988, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 718, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 69, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 8, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 9, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.0, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2222, "impact_of_cavity_insulation": -2310, "impact_of_solid_wall_insulation": -522, "space_heating_existing_dwelling": 16496}, "energy_consumption_current": 334, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 67, "calculation_software_version": "3.05r03", "energy_consumption_potential": 173, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061141428, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 55% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CT11 7QW", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "RAMSGATE", "built_form": 4, "created_at": "2018-05-08 20:32:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "42, Park Road", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.54, "quantity": "square metres"}, "party_wall_length": {"value": 30.11, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 14.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 45.24, "quantity": "square metres"}, "party_wall_length": {"value": 30.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.65, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 477, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 472, "currency": "GBP"}, "hot_water_cost_current": {"value": 263, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 163, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5224, "impact_of_loft_insulation": -608, "space_heating_existing_dwelling": 7757}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 97, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200082113, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW7 4AU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 1, "created_at": "2018-11-21 19:30:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 657}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Milton Road", "assessment_type": "RdSAP", "completion_date": "2018-11-21", "inspection_date": "2017-09-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 988, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 529, "currency": "GBP"}, "hot_water_cost_current": {"value": 225, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 37}, {"sequence": 2, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 139, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 97, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 90}, {"sequence": 3, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 255, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3229, "impact_of_loft_insulation": -321, "impact_of_cavity_insulation": -3477, "space_heating_existing_dwelling": 11713}, "energy_consumption_current": 460, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 129, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100110099086, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TS3 9LF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLESBROUGH", "built_form": 2, "created_at": "2018-07-13 07:26:52.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Carisbrooke Avenue", "assessment_type": "RdSAP", "completion_date": "2018-07-13", "inspection_date": "2018-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.76, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 41.76, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 616, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 573, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2140, "space_heating_existing_dwelling": 8936}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 129, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100030983825, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To external air, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 64% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NN17 2EW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CORBY", "built_form": 4, "created_at": "2018-05-01 22:09:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16400}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "4, Iona Road", "assessment_type": "RdSAP", "completion_date": "2018-05-01", "inspection_date": "2018-04-30", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-05-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.28, "quantity": "square metres"}, "party_wall_length": {"value": 6.47, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 41.28, "quantity": "square metres"}, "party_wall_length": {"value": 6.47, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.93, "quantity": "square metres"}, "party_wall_length": {"value": 6.47, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 2.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 64, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 692, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 597, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2732, "space_heating_existing_dwelling": 13021}, "energy_consumption_current": 258, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 144, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 207035916, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "N9 0PA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-26 19:40:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15247}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Shrubbery Road", "assessment_type": "RdSAP", "completion_date": "2018-06-26", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.08, "quantity": "square metres"}, "party_wall_length": {"value": 16.9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 32.33, "quantity": "square metres"}, "party_wall_length": {"value": 16.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 439, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 306, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1939, "impact_of_loft_insulation": -187, "impact_of_solid_wall_insulation": -2331, "space_heating_existing_dwelling": 7053}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 53, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100080349780, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SL6 2TE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 2, "created_at": "2018-03-12 18:57:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "88, Badger Close", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-12", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.372, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.263, "quantity": "square metres"}, "party_wall_length": {"value": 5.907, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.757, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 39.263, "quantity": "square metres"}, "party_wall_length": {"value": 5.907, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.201, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.455, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.444, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.118, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.996, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.59, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 708, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 671, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2201, "impact_of_loft_insulation": -3356, "space_heating_existing_dwelling": 12479}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 154, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100050555525, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 79% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO32 2SD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 1, "created_at": "2018-09-07 20:29:28.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17039}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "183, Greenshaw Drive", "address_line_2": "Wigginton", "assessment_type": "RdSAP", "completion_date": "2018-09-07", "inspection_date": "2018-09-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-09-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 44.24, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 79, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 767, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 698, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.9, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1892, "space_heating_existing_dwelling": 11051}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 174, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100050460457, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "YO14 0QR", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "FILEY", "built_form": 2, "created_at": "2018-04-16 18:11:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 605, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Hamerton Close", "address_line_2": "Hunmanby", "assessment_type": "RdSAP", "completion_date": "2018-04-16", "inspection_date": "2018-04-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-04-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.45, "quantity": "square metres"}, "party_wall_length": {"value": 6.14, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 766, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 313, "currency": "GBP"}, "hot_water_cost_current": {"value": 292, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 48}, {"sequence": 5, "typical_saving": {"value": 467, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 7, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.7, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 447, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 382, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 431, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2914, "impact_of_loft_insulation": -349, "space_heating_existing_dwelling": 6382}, "energy_consumption_current": 575, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 69, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 101, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100071130518, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WV13 3JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WILLENHALL", "built_form": 2, "created_at": "2018-09-19 10:46:33.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "127, Dilloways Lane", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.347, "quantity": "metres"}, "total_floor_area": {"value": 52.7, "quantity": "square metres"}, "party_wall_length": {"value": 6.947, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.119, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 618, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1650, "impact_of_loft_insulation": -5319, "space_heating_existing_dwelling": 9045}, "energy_consumption_current": 336, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 176, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10009307329, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS17 8GH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKTON-ON-TEES", "built_form": 3, "created_at": "2018-09-05 14:10:03.000000", "door_count": 1, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9900}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Harris Court", "address_line_2": "Thornaby", "assessment_type": "RdSAP", "completion_date": "2018-09-05", "inspection_date": "2018-08-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.42, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 33.16, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 288, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 288, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}, {"sequence": 2, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1970, "impact_of_loft_insulation": -263, "space_heating_existing_dwelling": 3950}, "energy_consumption_current": 144, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 50, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100090441510, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CO4 0AN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 1, "created_at": "2018-04-18 21:08:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16931}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "32, Broadlands Way", "assessment_type": "RdSAP", "completion_date": "2018-04-18", "inspection_date": "2018-04-18", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 16.44, "quantity": "square metres"}, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": {"value": 12.14, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.82, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 48.67, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 840, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 808, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 64}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2227, "impact_of_loft_insulation": -2052, "space_heating_existing_dwelling": 15565}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 195, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090076931, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PE7 1AT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 3, "created_at": "2018-02-22 12:03:26.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15269}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "24, Syers Lane", "address_line_2": "Whittlesey", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 151, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 19.99, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.81, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 40.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 64.45, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1349, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1080, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 71, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 62}], "co2_emissions_potential": 5.2, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2320, "impact_of_loft_insulation": -3687, "impact_of_solid_wall_insulation": -4895, "space_heating_existing_dwelling": 27752}, "energy_consumption_current": 288, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 71, "calculation_software_version": "3.04r01", "energy_consumption_potential": 193, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 235025323, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LN5 7TU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LINCOLN", "built_form": 3, "created_at": "2018-01-15 14:45:10.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10552}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2, Kirkby Street", "assessment_type": "RdSAP", "completion_date": "2018-01-15", "inspection_date": "2018-01-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.22, "quantity": "square metres"}, "party_wall_length": {"value": 7.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 26.74, "quantity": "square metres"}, "party_wall_length": {"value": 7.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.94, "quantity": "square metres"}, "party_wall_length": {"value": 5.33, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 855, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 515, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 208, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1903, "impact_of_loft_insulation": -3053, "impact_of_solid_wall_insulation": -4925, "space_heating_existing_dwelling": 15022}, "energy_consumption_current": 430, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 155, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10012109269, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX37 9LE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "UMBERLEIGH", "built_form": 1, "created_at": "2018-02-06 14:25:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2105, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9733}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and underfloor heating, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Bedport Byre", "address_line_2": "Burrington", "assessment_type": "RdSAP", "completion_date": "2018-02-06", "inspection_date": "2018-02-06", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 179, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-02-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.45, "quantity": "metres"}, "total_floor_area": {"value": 36.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.51, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 726, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and at least two room thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 688, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "co2_emissions_potential": 4.9, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 95, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2586, "space_heating_existing_dwelling": 16374}, "energy_consumption_current": 142, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 97, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100021364406, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RM2 5AX", "hot_water": {"description": {"value": "From main system, plus solar", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "ROMFORD", "built_form": 4, "created_at": "2018-09-18 12:51:19", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "207, Carlton Road", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.97, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.97, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "Y", "habitable_room_count": 5, "heating_cost_current": {"value": 657, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 438, "currency": "GBP"}, "hot_water_cost_current": {"value": 70, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "impact_of_cavity_insulation": -811, "impact_of_solid_wall_insulation": -1665, "space_heating_existing_dwelling": 12169}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100071157373, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 90% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WV11 2JU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WOLVERHAMPTON", "built_form": 4, "created_at": "2018-09-19 09:34:24.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 105, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "23, Ferguson Street", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 12.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 229, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 899, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 608, "currency": "GBP"}, "hot_water_cost_current": {"value": 186, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 6, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 8, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 248, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 59}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3094, "impact_of_loft_insulation": -3098, "impact_of_cavity_insulation": -1675, "impact_of_solid_wall_insulation": -702, "space_heating_existing_dwelling": 12976}, "energy_consumption_current": 462, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 195, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 82, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200004071293, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PR6 7TH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHORLEY", "built_form": 4, "created_at": "2018-04-23 17:24:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "94, The Martindales", "address_line_2": "Clayton-le-Woods", "assessment_type": "RdSAP", "completion_date": "2018-04-23", "inspection_date": "2018-04-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 42.86, "quantity": "square metres"}, "party_wall_length": {"value": 13.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.94, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 309, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 313, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1750, "impact_of_loft_insulation": -1224, "space_heating_existing_dwelling": 3463}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 212, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100110601290, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 31% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE23 2UH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CRAMLINGTON", "built_form": 4, "created_at": "2018-07-11 15:46:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "16, Abingdon Square", "assessment_type": "RdSAP", "completion_date": "2018-07-11", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.22, "quantity": "square metres"}, "party_wall_length": {"value": 9.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 46.2, "quantity": "square metres"}, "party_wall_length": {"value": 11.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 31, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 554, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 486, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2188, "impact_of_loft_insulation": -336, "space_heating_existing_dwelling": 9752}, "energy_consumption_current": 214, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 110, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200000203127, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU21 6NF", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WOKING", "built_form": 2, "created_at": "2018-02-01 12:55:22.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "170a, Goldsworth Road", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-01-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 44.73, "quantity": "square metres"}, "party_wall_length": {"value": 6.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 609, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 174, "currency": "GBP"}, "hot_water_cost_current": {"value": 172, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 172, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 139, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1620, "impact_of_solid_wall_insulation": -2296, "space_heating_existing_dwelling": 4260}, "energy_consumption_current": 422, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 268, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200003171621, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LL57 1BQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BANGOR", "built_form": 4, "created_at": "2018-02-22 13:52:28.000000", "door_count": 2, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "73, Mount Street", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.88, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.35, "quantity": "square metres"}, "party_wall_length": {"value": 13.74, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 26.42, "quantity": "square metres"}, "party_wall_length": {"value": 14.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.38, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 26.42, "quantity": "square metres"}, "party_wall_length": {"value": 14.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.38, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 502, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 345, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.9, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2092, "space_heating_existing_dwelling": 6423}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 63, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10013284769, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Some secondary glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DT10 2BX", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "STURMINSTER NEWTON", "built_form": 1, "created_at": "2018-05-28 09:29:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Piglet Cottage", "address_line_2": "Fiddleford", "assessment_type": "RdSAP", "completion_date": "2018-05-28", "inspection_date": "2018-05-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 24.81, "insulation": 5, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "150mm"}, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.08, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 842, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 306, "currency": "GBP"}, "hot_water_cost_current": {"value": 247, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 200, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 72}], "co2_emissions_potential": 1.8, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 255, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1771, "impact_of_solid_wall_insulation": -4252, "space_heating_existing_dwelling": 11697}, "energy_consumption_current": 687, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 25, "calculation_software_version": "3.05r04", "energy_consumption_potential": 175, "environmental_impact_current": 24, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 119, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100060592880, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO32 1RL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-01-05 10:19:47.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17553}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "8, Princes Close", "address_line_2": "Bishops Waltham", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 51.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.48, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2710, "space_heating_existing_dwelling": 8314}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 88, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100040944113, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TA1 3RX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "TAUNTON", "built_form": 2, "created_at": "2018-06-14 16:19:31.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "20 St. Georges Square", "address_line_2": "The Mount", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-14", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 42.66, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 21.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.07, "quantity": "square metres"}, "party_wall_length": {"value": 5.28, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 408, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 319, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.9, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 107, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2450, "impact_of_loft_insulation": -411, "space_heating_existing_dwelling": 4722}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 169, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 250033693, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 77% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BA11 2LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FROME", "built_form": 1, "created_at": "2018-04-18 08:18:48.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 779}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "63, Park Hill Drive", "assessment_type": "RdSAP", "completion_date": "2018-04-18", "inspection_date": "2018-04-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.03, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 41.03, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 22.94, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.44, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 24.58, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 77, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 690, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 553, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 180, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3126, "space_heating_existing_dwelling": 10489}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100010106371, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH65 4AE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ELLESMERE PORT", "built_form": 3, "created_at": "2018-05-18 14:00:39.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16388}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Cambridge Road", "assessment_type": "RdSAP", "completion_date": "2018-05-18", "inspection_date": "2018-05-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.96, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.38, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 45.38, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 646, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 427, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 190, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2203, "impact_of_solid_wall_insulation": -3379, "space_heating_existing_dwelling": 9434}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 76, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 200003169482, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL57 2UY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BANGOR", "built_form": 3, "created_at": "2018-04-26 18:23:02.000000", "door_count": 2, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1758}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31, Penchwintan Road", "assessment_type": "RdSAP", "completion_date": "2018-04-26", "inspection_date": "2018-04-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.91, "quantity": "square metres"}, "party_wall_length": {"value": 8.03, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 27.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.48, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 27.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.93, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.21, "quantity": "square metres"}, "party_wall_length": {"value": 3.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 8.21, "quantity": "square metres"}, "party_wall_length": {"value": 3.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.74, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.08, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.14, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.56, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 703, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 570, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2263, "impact_of_loft_insulation": -1635, "space_heating_existing_dwelling": 10888}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 113, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100071024110, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 21% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B43 7JY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2018-08-30 10:03:38.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "28, Horsley Road", "assessment_type": "RdSAP", "completion_date": "2018-08-30", "inspection_date": "2018-08-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.98, "quantity": "square metres"}, "party_wall_length": {"value": 6.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 45.74, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 21, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 897, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 644, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 227, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 320, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 56}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3043, "impact_of_loft_insulation": -3891, "space_heating_existing_dwelling": 13176}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 16, "calculation_software_version": "3.06r03", "energy_consumption_potential": 181, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10007807703, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "addendum_numbers": [1], "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 65% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TR11 5LG", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "FALMOUTH", "built_form": 1, "created_at": "2018-09-25 08:08:46.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15225}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Westholme", "address_line_2": "Budock Vean Lane", "address_line_3": "Mawnan Smith", "assessment_type": "RdSAP", "completion_date": "2018-09-25", "inspection_date": "2018-09-24", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 222, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-09-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 88.83, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 42.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 88.83, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 4.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.04, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 8, "wall_construction": 5, "building_part_number": 4, "sap_alternative_wall": {"wall_area": 3.2, "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 65, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1395, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 160, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 899, "currency": "GBP"}, "hot_water_cost_current": {"value": 180, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 3, "typical_saving": {"value": 255, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 7, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 8, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 9, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 10, "typical_saving": {"value": 349, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 62}], "co2_emissions_potential": 6.4, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 118, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 137, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 53}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4000, "impact_of_loft_insulation": -908, "impact_of_cavity_insulation": -5461, "space_heating_existing_dwelling": 29396}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 103, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 31, "current_energy_efficiency_band": "E", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100061002950, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN8 5JQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EDENBRIDGE", "built_form": 4, "created_at": "2018-09-24 17:14:33.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15189}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Stanbridge Road", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.6, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 38.1, "quantity": "square metres"}, "party_wall_length": {"value": 13.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.6, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 9.6, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 511, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 449, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2208, "impact_of_loft_insulation": -447, "impact_of_cavity_insulation": -1472, "space_heating_existing_dwelling": 8977}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 90, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200003967801, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "UB2 5NT", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SOUTHALL", "built_form": 4, "created_at": "2018-09-29 02:33:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "107, Burket Close", "assessment_type": "RdSAP", "completion_date": "2018-09-29", "inspection_date": "2018-09-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 0.98}, "total_floor_area": 32, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-09-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.3618, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.93, "quantity": "square metres"}, "party_wall_length": {"value": 10.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 287, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 140, "currency": "GBP"}, "hot_water_cost_current": {"value": 247, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 228, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 294, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 256, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 126, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1492, "space_heating_existing_dwelling": 1736}, "energy_consumption_current": 327, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 317, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100061488810, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 65% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "KT15 1NF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ADDLESTONE", "built_form": 1, "created_at": "2018-01-12 12:44:24.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15697}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, Rowhurst Avenue", "assessment_type": "RdSAP", "completion_date": "2018-01-12", "inspection_date": "2018-01-12", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-01-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 55.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 160, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 65, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 701, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 618, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2264, "impact_of_loft_insulation": -476, "space_heating_existing_dwelling": 9883}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 105, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 10012209337, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M14 5LY", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 3, "created_at": "2018-07-30 20:00:30.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "120, Hadfield Close", "assessment_type": "RdSAP", "completion_date": "2018-07-30", "inspection_date": "2018-07-27", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 2.9}, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-07-30", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.815, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 72, "quantity": "square metres"}, "party_wall_length": {"value": 14.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 2.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 297, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 191, "currency": "GBP"}, "hot_water_cost_current": {"value": 213, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 245, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 190, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2070, "space_heating_existing_dwelling": 2001}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 186, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100041195113, "roofs": [{"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ2 5QS", "hot_water": {"description": "Community scheme, no cylinder thermostat", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TORQUAY", "built_form": 5, "created_at": "2018-05-08 09:59:27.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "226 Union Street", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-04", "extensions_count": 3, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 16.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 8.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 27.88, "quantity": "square metres"}, "party_wall_length": {"value": 7.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.92, "quantity": "metres"}, "total_floor_area": {"value": 4.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 576, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, programmer and TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 340, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.3, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2863, "impact_of_loft_insulation": -1779, "impact_of_cavity_insulation": -788, "impact_of_solid_wall_insulation": -803, "space_heating_existing_dwelling": 8662}, "energy_consumption_current": 373, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "3.05r04", "energy_consumption_potential": 222, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 38077122, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L25 0NR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2018-06-25 19:54:54.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17985}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Hillfoot Avenue", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.99, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 41.55, "quantity": "square metres"}, "party_wall_length": {"value": 7.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.39, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.24, "quantity": "square metres"}, "party_wall_length": {"value": 4.12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 580, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 580, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2142, "impact_of_loft_insulation": -743, "space_heating_existing_dwelling": 10524}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["W2"], "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 135, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10009195637, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RG7 3BZ", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 5, "created_at": "2018-02-22 07:59:09.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "12 Blands Court", "address_line_2": "Reading Road", "address_line_3": "Burghfield Common", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 43.2, "quantity": "square metres"}, "party_wall_length": {"value": 13.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 232, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 204, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}}], "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1805, "space_heating_existing_dwelling": 2563}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 177, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080243256, "roofs": [{"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG7 5DE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 2, "created_at": "2018-03-14 09:56:53.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "115, Meadow Way", "address_line_2": "Theale", "assessment_type": "RdSAP", "completion_date": "2018-03-14", "inspection_date": "2018-03-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-03-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 45.06, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.32, "quantity": "square metres"}, "party_wall_length": {"value": 9.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.98, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 802, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 558, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 188, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2920, "impact_of_loft_insulation": -612, "space_heating_existing_dwelling": 12233}, "energy_consumption_current": 252, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 103, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10003332412, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO41 0YP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YARMOUTH", "built_form": 2, "created_at": "2018-01-14 21:47:30", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10453}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Seahaven", "address_line_2": "Port la Salle", "address_line_3": "Bouldnor", "assessment_type": "RdSAP", "completion_date": "2018-01-14", "inspection_date": "2018-01-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 283, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 7, "registration_date": "2018-01-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 3, "peak_power": 4, "orientation": 5, "overshading": 1, "pv_connection": 1}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 135.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 135.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 42.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.1, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1551, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 144, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1309, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 77}], "co2_emissions_potential": 4.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 146, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 111, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2390, "impact_of_loft_insulation": -773, "space_heating_existing_dwelling": 25622}, "energy_consumption_current": 117, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 46, "calculation_software_version": "3.03r04", "energy_consumption_potential": 94, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 200003259123, "roofs": [{"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA43 2PG", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "post_town": "CARDIGAN", "built_form": 1, "created_at": "2018-09-24 14:49:36.000000", "door_count": 0, "glazed_area": 2, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 9, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 158, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, dual fuel (mineral and wood)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Maes y Dderwen", "address_line_2": "Pontrhydyceirt", "address_line_3": "Cilgerran", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 122, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 56.95, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "350mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.32, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 979, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": "TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 709, "currency": "GBP"}, "hot_water_cost_current": {"value": 699, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}], "co2_emissions_potential": 3.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 130, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 7296, "impact_of_loft_insulation": -523, "space_heating_existing_dwelling": 13709}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 118, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 310074261, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG2 0FY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "READING", "built_form": 2, "created_at": "2018-02-01 22:46:28.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10071}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "47 Havergate Way", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-02-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 182, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 185, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1821, "space_heating_existing_dwelling": 1521}, "energy_consumption_current": 136, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 127, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100101008620, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SA31 2LF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARMARTHEN", "built_form": 2, "created_at": "2018-07-18 15:31:59.000000", "door_count": 3, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "5, Heol Blaengwastod", "assessment_type": "RdSAP", "completion_date": "2018-07-18", "inspection_date": "2018-07-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2018-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.91, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 42.99, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.02, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.09, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 687, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 611, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2165, "space_heating_existing_dwelling": 10230}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 120, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100721756, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CF42 5RH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TREORCHY", "built_form": 4, "created_at": "2018-09-27 15:37:05.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17983}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "57, Mount Libanus Street", "address_line_2": "Treherbert", "assessment_type": "RdSAP", "completion_date": "2018-09-27", "inspection_date": "2018-09-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.6, "quantity": "square metres"}, "party_wall_length": {"value": 13.28, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.65, "quantity": "metres"}, "total_floor_area": {"value": 32.6, "quantity": "square metres"}, "party_wall_length": {"value": 13.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.79, "quantity": "square metres"}, "party_wall_length": {"value": 3.33, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 722, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 462, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 159, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 6, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 1.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2005, "impact_of_cavity_insulation": -404, "impact_of_solid_wall_insulation": -3639, "space_heating_existing_dwelling": 13733}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 112, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060014850, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 35% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN21 1PU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EASTBOURNE", "built_form": 4, "created_at": "2018-05-12 07:10:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10504}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Motcombe Road", "assessment_type": "RdSAP", "completion_date": "2018-05-12", "inspection_date": "2018-05-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 149, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.5, "quantity": "square metres"}, "party_wall_length": {"value": 22.41, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.65, "quantity": "metres"}, "total_floor_area": {"value": 75.42, "quantity": "square metres"}, "party_wall_length": {"value": 22.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 35, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 750, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 138, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 594, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2991, "impact_of_loft_insulation": -717, "impact_of_cavity_insulation": -2585, "space_heating_existing_dwelling": 14177}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 87, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 17, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100090850449, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR31 7LN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GREAT YARMOUTH", "built_form": 2, "created_at": "2018-04-17 09:53:36.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17511}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "53, Nuffield Close", "address_line_2": "Gorleston", "assessment_type": "RdSAP", "completion_date": "2018-04-17", "inspection_date": "2018-04-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3.4}, "total_floor_area": 46, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-04-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.99, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.89, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 310, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 266, "currency": "GBP"}, "hot_water_cost_current": {"value": 69, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1526, "space_heating_existing_dwelling": 4377}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 170, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10023918169, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CA7 9HW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIGTON", "built_form": 4, "created_at": "2018-06-24 14:17:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10468}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "3 The Old Tannery", "address_line_2": "Reeds Lane", "assessment_type": "RdSAP", "completion_date": "2018-06-24", "inspection_date": "2018-06-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.9, "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 19.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2, "quantity": "metres"}, "total_floor_area": {"value": 19.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 312, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 318, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.8, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2170, "space_heating_existing_dwelling": 4459}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 72, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100071168404, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "WV2 2DQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 4, "created_at": "2018-05-22 15:49:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Joan Street", "assessment_type": "RdSAP", "completion_date": "2018-05-22", "inspection_date": "2018-05-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 22.357, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 1, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.403, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.02, "quantity": "square metres"}, "party_wall_length": {"value": 6.086, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.277, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.428, "quantity": "metres"}, "total_floor_area": {"value": 28.02, "quantity": "square metres"}, "party_wall_length": {"value": 6.086, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.208, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.428, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.901, "quantity": "square metres"}, "party_wall_length": 2.02, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.951, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 403, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 383, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2067, "impact_of_loft_insulation": -178, "impact_of_solid_wall_insulation": -558, "space_heating_existing_dwelling": 6495}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 100, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100120805078, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "OX4 4RN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OXFORD", "built_form": 3, "created_at": "2018-03-13 18:20:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17073}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "53, Asquith Road", "assessment_type": "RdSAP", "completion_date": "2018-03-13", "inspection_date": "2018-03-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-03-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15, "quantity": "square metres"}, "party_wall_length": {"value": 2.52, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.93, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 13.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.26, "quantity": "square metres"}, "party_wall_length": {"value": 3.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 15.26, "quantity": "square metres"}, "party_wall_length": {"value": 3.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.13, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 408, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 410, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1846, "space_heating_existing_dwelling": 6604}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 106, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100020701264, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR7 7QD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "THORNTON HEATH", "built_form": 4, "created_at": "2018-08-08 15:17:51.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8077}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "68, Richmond Road", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-08-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.2, "quantity": "square metres"}, "party_wall_length": {"value": 18.85, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 48.2, "quantity": "square metres"}, "party_wall_length": {"value": 18.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.14, "quantity": "square metres"}, "party_wall_length": {"value": 1.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.42, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 676, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 426, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2238, "impact_of_loft_insulation": -762, "impact_of_solid_wall_insulation": -2771, "space_heating_existing_dwelling": 10430}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 80, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 21, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 74040599, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S40 1EP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTERFIELD", "built_form": 2, "created_at": "2018-09-03 15:03:52.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "60, Vernon Road", "assessment_type": "RdSAP", "completion_date": "2018-09-03", "inspection_date": "2018-09-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.81, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 40.81, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 649, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 590, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1975, "space_heating_existing_dwelling": 9600}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 136, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100110102266, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 58% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TS5 7DD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLESBROUGH", "built_form": 2, "created_at": "2018-09-19 08:25:29.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17216}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "54, Coniston Grove", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.49, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 37.82, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.97, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 7.97, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 58, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 728, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 579, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2038, "impact_of_loft_insulation": -471, "space_heating_existing_dwelling": 11776}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 137, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100040259147, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX33 1AH", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRAUNTON", "built_form": 6, "created_at": "2018-03-11 16:23:27.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2303, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 Caen House", "address_line_2": "Caen Street", "assessment_type": "RdSAP", "completion_date": "2018-03-11", "inspection_date": "2018-03-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 56, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-03-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 650, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.31, "quantity": "square metres"}, "party_wall_length": {"value": 10.96, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 333, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 199, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1955, "impact_of_solid_wall_insulation": -1911, "space_heating_existing_dwelling": 4360}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 140, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100031645680, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WS15 2JR", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "RUGELEY", "built_form": 2, "created_at": "2018-07-05 17:02:51.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "115, Queen Street", "assessment_type": "RdSAP", "completion_date": "2018-07-05", "inspection_date": "2018-07-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-07-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 45.66, "quantity": "square metres"}, "party_wall_length": {"value": 8.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 435, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 283, "currency": "GBP"}, "hot_water_cost_current": {"value": 165, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 193, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 141, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1944, "impact_of_loft_insulation": -1048, "space_heating_existing_dwelling": 4549}, "energy_consumption_current": 467, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 338, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050663182, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 23% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "S73 8QB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNSLEY", "built_form": 2, "created_at": "2018-05-08 13:47:50.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9209}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "255, Summer Lane", "address_line_2": "Wombwell", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.25, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 23, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 749, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 612, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 127, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2041, "impact_of_loft_insulation": -3298, "space_heating_existing_dwelling": 11413}, "energy_consumption_current": 340, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 178, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 257260, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 36% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BS9 1HA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2018-01-26 11:26:13", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15748}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Kewstoke Road", "assessment_type": "RdSAP", "completion_date": "2018-01-26", "inspection_date": "2018-01-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 158, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-01-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5, "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 32.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 58.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.54, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 7.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.17, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 8.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1074, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 142, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 788, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2851, "impact_of_loft_insulation": -218, "impact_of_cavity_insulation": -4531, "space_heating_existing_dwelling": 20019}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "3.03r05", "energy_consumption_potential": 117, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 28, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": null, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B14 7AP", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 1}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-08-28 13:11:25.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 950, "water_heating_fuel": 25, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 11", "address_line_2": "Robins View", "address_line_3": "4 Ashfield Avenue", "assessment_type": "RdSAP", "completion_date": "2018-08-28", "inspection_date": "2018-08-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 43, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-08-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 43.43, "quantity": "square metres"}, "party_wall_length": {"value": 18.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 580, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 302, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 55}], "co2_emissions_potential": 3.0, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 309, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 256, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1807, "impact_of_loft_insulation": -1164, "impact_of_cavity_insulation": -502, "space_heating_existing_dwelling": 3248}, "energy_consumption_current": 431, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 403, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 55, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 25110211, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK5 6FT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MILTON KEYNES", "built_form": 1, "created_at": "2018-05-26 17:34:27.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17955}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "14, Downhill Close", "address_line_2": "Shenley Church End", "assessment_type": "RdSAP", "completion_date": "2018-05-26", "inspection_date": "2018-05-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 5.9}, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.747, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 57.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 239, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 239, "currency": "GBP"}, "hot_water_cost_current": {"value": 68, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1503, "space_heating_existing_dwelling": 2840}, "energy_consumption_current": 129, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 129, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100110413108, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DH7 7LE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DURHAM", "built_form": 2, "created_at": "2018-05-26 16:01:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15695}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Flass Avenue", "address_line_2": "Ushaw Moor", "assessment_type": "RdSAP", "completion_date": "2018-05-26", "inspection_date": "2018-05-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 744, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 553, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2026, "impact_of_cavity_insulation": -2503, "space_heating_existing_dwelling": 11212}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 142, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10023541518, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF15 8GJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 2, "created_at": "2018-09-29 07:40:09.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10071}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, Maes y Llech", "address_line_2": "Radyr", "assessment_type": "RdSAP", "completion_date": "2018-09-29", "inspection_date": "2018-09-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.9, "quantity": "square metres"}, "party_wall_length": {"value": 8.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 37.9, "quantity": "square metres"}, "party_wall_length": {"value": 8.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 336, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 316, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2447, "space_heating_existing_dwelling": 5046}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 52, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10093995419, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW9 5HD", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-25 07:38:38.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 950, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "22 Patton Studios", "address_line_2": "126 Colindale Avenue", "assessment_type": "RdSAP", "completion_date": "2018-09-25", "inspection_date": "2018-09-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 32, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-09-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 325, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 20.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 163, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 115, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1695, "space_heating_existing_dwelling": 724}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 182, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10002474596, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 18% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PO18 9EN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHICHESTER", "built_form": 1, "created_at": "2018-08-09 00:51:38.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 914, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 0.9, "sap_main_heating_code": 191, "central_heating_pump_age": 0, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 0.1, "sap_main_heating_code": 140, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Court Cottage", "address_line_2": "West Marden", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-07-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 121, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 1.99, "quantity": "metres"}, "total_floor_area": {"value": 30.96, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 15.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.03, "quantity": "metres"}, "total_floor_area": {"value": 23.49, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.17, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2, "quantity": "metres"}, "total_floor_area": {"value": 6.17, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 2431, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 19, "lighting_cost_current": {"value": 141, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1212, "currency": "GBP"}, "hot_water_cost_current": {"value": 147, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 20, "environmental_impact_rating": 23}, {"sequence": 2, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 26, "environmental_impact_rating": 28}, {"sequence": 3, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 33}, {"sequence": 4, "typical_saving": {"value": 178, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 36}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 38}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 38}, {"sequence": 7, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 40}, {"sequence": 8, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 43}, {"sequence": 9, "typical_saving": {"value": 225, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 48}, {"sequence": 10, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 49}, {"sequence": 11, "typical_saving": {"value": 342, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}], "co2_emissions_potential": 4.4, "energy_rating_potential": 60, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 156, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 29, "environmental_impact_rating": 30}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2951, "impact_of_loft_insulation": -813, "impact_of_cavity_insulation": -2194, "impact_of_solid_wall_insulation": -2288, "space_heating_existing_dwelling": 17240}, "energy_consumption_current": 487, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 15, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 193, "environmental_impact_current": 22, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "G", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 91, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100011494655, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SK6 6HS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKPORT", "built_form": 1, "created_at": "2018-03-10 16:52:13.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Kingsbridge Close", "address_line_2": "Marple", "assessment_type": "RdSAP", "completion_date": "2018-03-10", "inspection_date": "2018-03-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-03-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 52.5, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 662, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 607, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2410, "space_heating_existing_dwelling": 12013}, "energy_consumption_current": 189, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10035304954, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 92% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL16 5RU", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "DENBIGH", "built_form": 1, "created_at": "2018-08-28 13:20:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 800031}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Henfryn Farm", "address_line_2": "Groes", "assessment_type": "RdSAP", "completion_date": "2018-08-28", "inspection_date": "2018-08-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 125, "transaction_type": 2, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-08-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 58.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1104, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.5, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 669, "currency": "GBP"}, "hot_water_cost_current": {"value": 182, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 35}, {"sequence": 3, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 5, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 48}, {"sequence": 6, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 37}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 7, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 8, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 63}, {"sequence": 9, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.6, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 143, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 51}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3649, "impact_of_loft_insulation": -534, "impact_of_cavity_insulation": -4611, "space_heating_existing_dwelling": 18750}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 41, "environmental_impact_current": 33, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100061776673, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH10 1QE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CRAWLEY", "built_form": 1, "created_at": "2018-03-06 16:51:21.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1758}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "94, Gales Drive", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-03-06", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 145, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.92, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 46.92, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.96, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.49, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 976, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 880, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 4.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2315, "impact_of_loft_insulation": -4340, "space_heating_existing_dwelling": 17154}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 159, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100012609564, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "FY1 5LA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKPOOL", "built_form": 3, "created_at": "2018-03-12 07:15:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "16, Levens Grove", "assessment_type": "RdSAP", "completion_date": "2018-03-12", "inspection_date": "2018-03-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 11.4, "quantity": "metres"}}, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 28.842, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 95.16, "quantity": "square metres"}, "party_wall_length": {"value": 9.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 43.24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 417, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 368, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2053, "impact_of_solid_wall_insulation": -1027, "space_heating_existing_dwelling": 6236}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 131, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100070278972, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B21 9HY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-03-10 22:28:28.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16694}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "12, Arthur Road", "address_line_2": "Handsworth", "assessment_type": "RdSAP", "completion_date": "2018-03-10", "inspection_date": "2018-03-09", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.87, "quantity": "square metres"}, "party_wall_length": {"value": 11.82, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 38.03, "quantity": "square metres"}, "party_wall_length": {"value": 19.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 898, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 587, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 164, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 110, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2140, "impact_of_loft_insulation": -3282, "impact_of_solid_wall_insulation": -3940, "space_heating_existing_dwelling": 16293}, "energy_consumption_current": 368, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 159, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060475647, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 10% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SO41 0LG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LYMINGTON", "built_form": 1, "created_at": "2018-05-27 10:34:00.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8193}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Downton Lane", "address_line_2": "Downton", "assessment_type": "RdSAP", "completion_date": "2018-05-27", "inspection_date": "2018-05-25", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 140, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "registration_date": "2018-05-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 21.3, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 85.58, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.35, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.92, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 10, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 870, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 154, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 681, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": 90, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 331, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}], "co2_emissions_potential": 4.2, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2312, "impact_of_loft_insulation": -1276, "space_heating_existing_dwelling": 15202}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 109, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100050647493, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S70 5AL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNSLEY", "built_form": 4, "created_at": "2018-02-02 14:39:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "39, Park Road", "address_line_2": "Worsbrough", "assessment_type": "RdSAP", "completion_date": "2018-02-02", "inspection_date": "2018-02-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.02, "wall_dry_lined": "N", "wall_construction": 2, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.42, "quantity": "square metres"}, "party_wall_length": {"value": 20.58, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 39.06, "quantity": "square metres"}, "party_wall_length": {"value": 17.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 802, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 623, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2131, "impact_of_loft_insulation": -3811, "impact_of_solid_wall_insulation": -2496, "space_heating_existing_dwelling": 14007}, "energy_consumption_current": 312, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 173, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10034633294, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR7 1AT", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NEWQUAY", "built_form": 4, "created_at": "2018-08-30 08:22:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "6 Berry Road", "assessment_type": "RdSAP", "completion_date": "2018-08-30", "inspection_date": "2018-08-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.86}, "total_floor_area": 43, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-30", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 700, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 10.692, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 100, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 42.96, "quantity": "square metres"}, "party_wall_length": {"value": 13.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 441, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 138, "currency": "GBP"}, "hot_water_cost_current": {"value": 271, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 238, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 68}], "co2_emissions_potential": 1.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 302, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 265, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1635, "impact_of_loft_insulation": -419, "impact_of_solid_wall_insulation": -766, "space_heating_existing_dwelling": 2665}, "energy_consumption_current": 322, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 244, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10000032961, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PE34 4QX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "KING'S LYNN", "built_form": 1, "created_at": "2018-04-10 17:14:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15875}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, LPG", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "12, Magdalen Road", "address_line_2": "Tilney St. Lawrence", "assessment_type": "RdSAP", "completion_date": "2018-04-10", "inspection_date": "2018-04-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-04-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 102.23, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 42.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1011, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 785, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2245, "space_heating_existing_dwelling": 11422}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 94, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10009556254, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HR2 0ES", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "HEREFORD", "built_form": 1, "created_at": "2018-05-01 14:48:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Bridge Cottage", "address_line_2": "Ewyas Harold", "assessment_type": "RdSAP", "completion_date": "2018-05-01", "inspection_date": "2018-04-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 580, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 1.97, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.87, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 1.9, "quantity": "metres"}, "total_floor_area": {"value": 37.37, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1141, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.1, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 480, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 512, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 618, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 107, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 107, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 182, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 95, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1959, "impact_of_solid_wall_insulation": -7180, "space_heating_existing_dwelling": 15897}, "energy_consumption_current": 607, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 86, "environmental_impact_current": 23, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100020227770, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 88% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DA8 2HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ERITH", "built_form": 4, "created_at": "2018-10-25 12:59:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Craydene Road", "assessment_type": "RdSAP", "completion_date": "2018-10-25", "inspection_date": "2018-07-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.54, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.5, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "200mm"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 404, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 334, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2136, "space_heating_existing_dwelling": 5616}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 59, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10070039788, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SG3 6PR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KNEBWORTH", "built_form": 3, "created_at": "2018-06-29 15:34:22.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8867}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "172, Park Lane", "address_line_2": "Old Knebworth", "assessment_type": "RdSAP", "completion_date": "2018-06-29", "inspection_date": "2018-06-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.5, "quantity": "square metres"}, "party_wall_length": {"value": 4.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 47.5, "quantity": "square metres"}, "party_wall_length": {"value": 4.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 810, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 778, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.3, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2749, "impact_of_loft_insulation": -437, "space_heating_existing_dwelling": 15689}, "energy_consumption_current": 288, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 196, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110372953, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DH8 7QU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CONSETT", "built_form": 4, "created_at": "2018-04-06 09:22:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "75, Dunelm Walk", "assessment_type": "RdSAP", "completion_date": "2018-04-06", "inspection_date": "2018-04-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.85, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 38.85, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 450, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 457, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.6, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2137, "space_heating_existing_dwelling": 7516}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 113, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031532131, "roofs": [{"description": {"value": "Pitched, *** INVALID INPUT Code : 57 *** loft insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NG5 5TH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-06-26 18:15:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "84, Cherry Orchard Mount", "assessment_type": "RdSAP", "completion_date": "2018-06-26", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.8, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.8, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 851, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 646, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2222, "impact_of_cavity_insulation": -2238, "space_heating_existing_dwelling": 11706}, "energy_consumption_current": 362, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 191, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10008536848, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DY4 7RD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TIPTON", "built_form": 4, "created_at": "2018-08-21 17:16:51.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8703}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "58, Anchor Drive", "assessment_type": "RdSAP", "completion_date": "2018-08-21", "inspection_date": "2018-08-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 15.1, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.38, "quantity": "square metres"}, "party_wall_length": {"value": 15.58, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 30.38, "quantity": "square metres"}, "party_wall_length": {"value": 15.58, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 322, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 322, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2795, "space_heating_existing_dwelling": 4763}, "energy_consumption_current": 159, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 76, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10008231176, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "E8 1LW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2018-07-16 11:18:34.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 66 Marcon Court", "address_line_2": "Amhurst Road", "assessment_type": "RdSAP", "completion_date": "2018-07-16", "inspection_date": "2018-05-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.4, "quantity": "metres"}}, "total_floor_area": 61, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.664, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 414, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 234, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2186, "impact_of_solid_wall_insulation": -2979, "space_heating_existing_dwelling": 6732}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 129, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100012346527, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH1 4HF", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CHESTER", "built_form": 4, "created_at": "2018-08-21 21:26:52.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16179}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "31, Bouverie Street", "assessment_type": "RdSAP", "completion_date": "2018-08-21", "inspection_date": "2018-08-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 137, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.75, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 42.75, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.5, "quantity": "square metres"}, "party_wall_length": 6.5, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 19.5, "quantity": "square metres"}, "party_wall_length": 6.5, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12, "quantity": "square metres"}, "party_wall_length": 5, "floor_construction": 1, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 883, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 582, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3660, "impact_of_loft_insulation": -826, "impact_of_solid_wall_insulation": -4818, "space_heating_existing_dwelling": 16555}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 100, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 10093039186, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG1 1TZ", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-01-16 16:56:20.000000", "door_count": 0, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "553e High Road", "assessment_type": "RdSAP", "completion_date": "2018-01-16", "inspection_date": "2018-01-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1, "quantity": "metres"}}, "total_floor_area": 11, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-01-16", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.4, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 160, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 10.6, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 22, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.5, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 15, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 22, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 15, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 816, "space_heating_existing_dwelling": 138}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 303, "environmental_impact_current": 86, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "B", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100022230308, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 27% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "IG2 7PL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-02-22 07:55:53.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 6, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9899}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "34, Oaks Lane", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.66, "quantity": "square metres"}, "party_wall_length": {"value": 15.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.66, "quantity": "square metres"}, "party_wall_length": {"value": 15.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 27, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 487, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 362, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2181, "impact_of_loft_insulation": -420, "impact_of_solid_wall_insulation": -2237, "space_heating_existing_dwelling": 8348}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 63, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100031220599, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG17 8BE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2018-04-12 09:40:03.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4016}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "28, Birch Tree Crescent", "address_line_2": "Kirkby-in-Ashfield", "assessment_type": "RdSAP", "completion_date": "2018-04-12", "inspection_date": "2018-04-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 96.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 37.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1449, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1112, "currency": "GBP"}, "hot_water_cost_current": {"value": 215, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}], "co2_emissions_potential": 4.6, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 84, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 520, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 56}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3629, "impact_of_loft_insulation": -5691, "space_heating_existing_dwelling": 20244}, "energy_consumption_current": 415, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 238, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100022744157, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W10 4EH", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-14 16:17:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 7 Fir House", "address_line_2": "7, Droop Street", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-01", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 39.1, "quantity": "square metres"}, "party_wall_length": {"value": 11.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 7.4, "quantity": "square metres"}, "party_wall_length": {"value": 1.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 164, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 171, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2284, "space_heating_existing_dwelling": 1364}, "energy_consumption_current": 161, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 147, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10009195413, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 6% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RG14 1TB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWBURY", "built_form": 4, "created_at": "2018-06-26 20:47:06.000000", "door_count": 3, "glazed_area": 2, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "27, Old College Road", "assessment_type": "RdSAP", "completion_date": "2018-06-26", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.12, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 37.12, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 6, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 399, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 105, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 352, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 155, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2402, "space_heating_existing_dwelling": 5729}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 68, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 33, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100030748301, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 63% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PE21 0NT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOSTON", "built_form": 2, "created_at": "2018-06-24 16:56:29.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "55, Wing Drive", "address_line_2": "Fishtoft", "assessment_type": "RdSAP", "completion_date": "2018-06-24", "inspection_date": "2018-06-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.42, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.61, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 30.42, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 345, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 309, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2269, "impact_of_loft_insulation": -215, "space_heating_existing_dwelling": 4219}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 55, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100011393497, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "M30 8ND", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-02-07 18:35:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "5, Wain Close", "address_line_2": "Eccles", "assessment_type": "RdSAP", "completion_date": "2018-02-07", "inspection_date": "2018-02-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 5.3}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.455, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.02, "quantity": "square metres"}, "party_wall_length": {"value": 14.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 252, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 225, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1797, "impact_of_solid_wall_insulation": -238, "space_heating_existing_dwelling": 3092}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 154, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10090960004, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN4 8QR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 3, "created_at": "2018-06-15 21:59:17", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2207, "main_heating_category": 4, "main_heating_fraction": 1, "sap_main_heating_code": 221, "mcs_installed_heat_pump": "true", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Ground source heat pump, underfloor, electric", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "Stable 1 Wickfield Farm", "address_line_2": "Royal Wootton Bassett", "assessment_type": "RdSAP", "completion_date": "2018-06-15", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 30, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-06-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": "NR", "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [7], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.1, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 207, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 28, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 207, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.0, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 28, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1029, "space_heating_existing_dwelling": 2708}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["W2", "X"], "calculation_software_version": "3.05r03", "energy_consumption_potential": 199, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 5, "multiple_glazed_proportion_nr": "NR", "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100030909188, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NG33 4NR", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "GRANTHAM", "built_form": 2, "created_at": "2018-08-10 15:57:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "25, Bourne Road", "address_line_2": "Corby Glen", "assessment_type": "RdSAP", "completion_date": "2018-08-10", "inspection_date": "2018-08-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 430, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.1, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.16, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.59, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1132, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 38, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 674, "currency": "GBP"}, "hot_water_cost_current": {"value": 258, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 28}, {"sequence": 2, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 33}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 33}, {"sequence": 4, "typical_saving": {"value": 344, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 45}, {"sequence": 6, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 54}], "co2_emissions_potential": 3.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 47, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 566, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 420, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1780, "impact_of_loft_insulation": -957, "impact_of_cavity_insulation": -899, "space_heating_existing_dwelling": 11977}, "energy_consumption_current": 748, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 367, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 126, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100070014735, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 42% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TF9 1LP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARKET DRAYTON", "built_form": 1, "created_at": "2018-06-11 20:01:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17663}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "57, Buntingsdale Road", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-11", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 118, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.98, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 20.97, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 16.89, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.68, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.01, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 14.08, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1476, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.3, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 926, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 465, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 6, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "co2_emissions_potential": 4.1, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2153, "impact_of_loft_insulation": -4289, "impact_of_solid_wall_insulation": -9634, "space_heating_existing_dwelling": 27030}, "energy_consumption_current": 401, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 65, "calculation_software_version": "2.0.x", "energy_consumption_potential": 196, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100023056639, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "KT1 2LL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KINGSTON UPON THAMES", "built_form": 1, "created_at": "2018-06-26 17:23:02.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1849}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 7", "address_line_2": "37, Uxbridge Road", "assessment_type": "RdSAP", "completion_date": "2018-06-26", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 4.7}, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.408, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 91.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 42.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 640, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 319, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 75, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 126, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2975, "impact_of_solid_wall_insulation": -5683, "space_heating_existing_dwelling": 10330}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "3.05r03", "energy_consumption_potential": 129, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 63073700, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF1 3TD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WAKEFIELD", "built_form": 2, "created_at": "2018-06-07 09:18:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17477}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, Meadow Vale", "address_line_2": "Outwood", "assessment_type": "RdSAP", "completion_date": "2018-06-07", "inspection_date": "2018-06-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.17, "quantity": "square metres"}, "party_wall_length": {"value": 8.69, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 30.38, "quantity": "square metres"}, "party_wall_length": {"value": 7.89, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 516, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1963, "impact_of_loft_insulation": -190, "space_heating_existing_dwelling": 8019}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 125, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100120617060, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "B97 5RT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "REDDITCH", "built_form": 1, "created_at": "2018-08-29 12:54:49.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10068}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Downsell Road", "assessment_type": "RdSAP", "completion_date": "2018-08-29", "inspection_date": "2018-08-29", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-08-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.74, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 38.74, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 20.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.06, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.55, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 772, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 573, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 84, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2198, "impact_of_loft_insulation": -574, "impact_of_cavity_insulation": -3443, "space_heating_existing_dwelling": 14964}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 136, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 20694, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true", "narrow_cavities": "true"}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS9 2PS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-07-18 12:34:14.000000", "door_count": 0, "glazed_area": 2, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "55, Westbury Lane", "assessment_type": "RdSAP", "completion_date": "2018-07-18", "inspection_date": "2018-07-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.25, "quantity": "square metres"}, "party_wall_length": {"value": 2.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 22.25, "quantity": "square metres"}, "party_wall_length": {"value": 2.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.25, "quantity": "square metres"}, "party_wall_length": {"value": 2.44, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 22.25, "quantity": "square metres"}, "party_wall_length": {"value": 2.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 730, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 240, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 197, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 226, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3543, "impact_of_loft_insulation": -490, "space_heating_existing_dwelling": 9851}, "energy_consumption_current": 315, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.0.x", "energy_consumption_potential": 95, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10002568780, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CB4 3QF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 1, "created_at": "2018-06-16 12:16:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 27, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18220}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, LPG", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50a, Canterbury Street", "assessment_type": "RdSAP", "completion_date": "2018-06-16", "inspection_date": "2018-06-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 25, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.59, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 439, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 307, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 22, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1371, "impact_of_loft_insulation": -254, "space_heating_existing_dwelling": 4845}, "energy_consumption_current": 357, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": -6, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10000853262, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8], "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WR1 2AG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "WORCESTER", "built_form": 2, "created_at": "2018-03-06 11:38:01", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "9, Nashs & Wyatts Almshouses", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-01-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 9.55}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 2, "peak_power": 1.47, "orientation": 5, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 23.3975, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.54, "quantity": "square metres"}, "party_wall_length": {"value": 6.48, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 356, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 243, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 92, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 88}, {"sequence": 4, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.6, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 82}}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1938, "impact_of_cavity_insulation": -709, "impact_of_solid_wall_insulation": -734, "space_heating_existing_dwelling": 5032}, "energy_consumption_current": 181, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 89, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 47056243, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 94% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE26 2EG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WHITLEY BAY", "built_form": 4, "created_at": "2018-06-10 20:17:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15697}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Lish Avenue", "assessment_type": "RdSAP", "completion_date": "2018-06-10", "inspection_date": "2018-06-08", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 180, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-06-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 400, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 39.47, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.2, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 47.2, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 2.3, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.61, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 19.61, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "Y", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.6, "quantity": "square metres"}, "party_wall_length": {"value": 1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 94, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1736, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.6, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1077, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 383, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 162, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}], "co2_emissions_potential": 5.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 109, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2336, "impact_of_loft_insulation": -1814, "impact_of_solid_wall_insulation": -3095, "space_heating_existing_dwelling": 34003}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 157, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 10033879677, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HD6 3DY", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRIGHOUSE", "built_form": 4, "created_at": "2018-09-18 19:36:16.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 13 The Old Chapel", "address_line_2": "Bridge End", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 38.68, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 38.68, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 300, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 176, "currency": "GBP"}, "hot_water_cost_current": {"value": 331, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 392, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 86, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 338, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 87}], "hot_water_cost_potential": {"value": 168, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1998, "space_heating_existing_dwelling": 1810}, "energy_consumption_current": 175, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 174, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100022688245, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW11 5LU", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-05-24 09:24:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10504}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "121, Sabine Road", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, smokeless fuel", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.09, "quantity": "square metres"}, "party_wall_length": {"value": 16.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 37.32, "quantity": "square metres"}, "party_wall_length": {"value": 16.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 604, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 344, "currency": "GBP"}, "hot_water_cost_current": {"value": 174, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 37, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 8, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3439, "impact_of_loft_insulation": -185, "impact_of_solid_wall_insulation": -2624, "space_heating_existing_dwelling": 9527}, "energy_consumption_current": 289, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r04", "energy_consumption_potential": 68, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040069666, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR20 9RE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "PENZANCE", "built_form": 3, "created_at": "2018-11-11 12:39:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17519}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "end-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "40, Pengersick Estate", "address_line_2": "Praa Sands", "assessment_type": "RdSAP", "completion_date": "2018-11-11", "inspection_date": "2018-11-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.87, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.18, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "150mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 193, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 154, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 337, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 80}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2914, "space_heating_existing_dwelling": 3750}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 32, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100031610953, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG3 4JJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-12-06 10:12:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "341, Woodborough Road", "assessment_type": "RdSAP", "completion_date": "2018-12-06", "inspection_date": "2018-12-05", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.9, "quantity": "metres"}}, "total_floor_area": 111, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-12-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.07, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 160, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "total_floor_area": {"value": 45.86, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 44.06, "quantity": "square metres"}, "party_wall_length": {"value": 8.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 21.37, "quantity": "square metres"}, "party_wall_length": {"value": 5.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 614, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 390, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 224, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2209, "impact_of_loft_insulation": -412, "impact_of_solid_wall_insulation": -5190, "space_heating_existing_dwelling": 11412}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 34063891, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 14% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SW6 3ET", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-11 18:53:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "43, Dymock Street", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-08", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3.21}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.5065, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.66, "quantity": "square metres"}, "party_wall_length": {"value": 10.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.68, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 382, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 251, "currency": "GBP"}, "hot_water_cost_current": {"value": 70, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1551, "impact_of_solid_wall_insulation": -1361, "space_heating_existing_dwelling": 6022}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r03", "energy_consumption_potential": 146, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100010982206, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BL9 5HQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURY", "built_form": 3, "created_at": "2018-09-18 21:07:57.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15206}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Woodman Drive", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.52, "quantity": "square metres"}, "party_wall_length": {"value": 6.12, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 34.52, "quantity": "square metres"}, "party_wall_length": {"value": 6.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 488, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1989, "impact_of_loft_insulation": -384, "space_heating_existing_dwelling": 8286}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 132, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 48103559, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW19 1JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-03-23 11:03:48.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9227}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Top Floor Flat", "address_line_2": "3 Kingston Road", "assessment_type": "RdSAP", "completion_date": "2018-03-23", "inspection_date": "2018-03-22", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.0, "quantity": "metres"}}, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-03-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 40.11, "quantity": "square metres"}, "party_wall_length": {"value": 15.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 27.79, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 577, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 502, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.9, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1974, "impact_of_loft_insulation": -5593, "impact_of_solid_wall_insulation": -2126, "space_heating_existing_dwelling": 10083}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 239, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200003640033, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "AL5 4AQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARPENDEN", "built_form": 2, "created_at": "2018-10-05 15:21:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "1 Maple Flats", "address_line_2": "Clarence Road", "assessment_type": "RdSAP", "completion_date": "2018-10-05", "inspection_date": "2018-10-04", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 4.72}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.216, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.77, "quantity": "square metres"}, "party_wall_length": {"value": 1.87, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.18, "quantity": "square metres"}, "party_wall_length": {"value": 2.96, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 255, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1771, "impact_of_solid_wall_insulation": -3184, "space_heating_existing_dwelling": 8236}, "energy_consumption_current": 389, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.08r07", "energy_consumption_potential": 201, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10003601075, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HG3 5EB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROGATE", "built_form": 1, "created_at": "2018-09-10 20:17:59.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16408}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Mistal Mayfield Farm", "address_line_2": "Wilsill", "assessment_type": "RdSAP", "completion_date": "2018-09-10", "inspection_date": "2018-09-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-09-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 33.33, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.02, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1030, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 586, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 161, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 219, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2661, "impact_of_loft_insulation": -152, "impact_of_solid_wall_insulation": -4586, "space_heating_existing_dwelling": 20099}, "energy_consumption_current": 375, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 147, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 4510080714, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE2 3HP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 4, "created_at": "2018-07-24 18:42:33.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17145}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "98, Bayswater Road", "assessment_type": "RdSAP", "completion_date": "2018-07-24", "inspection_date": "2018-07-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 79, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "total_floor_area": {"value": 79.15, "quantity": "square metres"}, "party_wall_length": {"value": 24.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 465, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 315, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1793, "impact_of_solid_wall_insulation": -2200, "space_heating_existing_dwelling": 7426}, "energy_consumption_current": 188, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 130, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100100509941, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CF35 6JB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIDGEND", "built_form": 2, "created_at": "2018-05-08 19:30:08", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "3, Greenacre Drive", "address_line_2": "Pencoed", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.78, "quantity": "square metres"}, "party_wall_length": {"value": 9.28, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.38, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 438, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 361, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1871, "impact_of_loft_insulation": -664, "space_heating_existing_dwelling": 6543}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 73, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 42148768, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH41 2YQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRKENHEAD", "built_form": 4, "created_at": "2018-08-10 09:06:25.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "9 Hollybank Court", "address_line_2": "4, Hollybank Road", "assessment_type": "RdSAP", "completion_date": "2018-08-10", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.7}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.71, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 58.29, "quantity": "square metres"}, "party_wall_length": {"value": 13.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 215, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 215, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2048, "impact_of_cavity_insulation": -292, "space_heating_existing_dwelling": 1797}, "energy_consumption_current": 118, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 118, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 4510032748, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE6 5XP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 4, "created_at": "2018-11-03 14:38:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10554}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "20, Meldon Terrace", "assessment_type": "RdSAP", "completion_date": "2018-11-03", "inspection_date": "2018-11-03", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "total_floor_area": {"value": 4.59, "quantity": "square metres"}, "party_wall_length": {"value": 11.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 0.84, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 62.55, "quantity": "square metres"}, "party_wall_length": {"value": 16.56, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.71, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 14.17, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 15.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 392, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 347, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 102, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2122, "impact_of_solid_wall_insulation": -1097, "space_heating_existing_dwelling": 6136}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 148, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100071177475, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WV3 0UU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 4, "created_at": "2018-10-09 22:57:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8575}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Merridale Gardens", "assessment_type": "RdSAP", "completion_date": "2018-10-09", "inspection_date": "2018-10-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 242, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.42, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 39.42, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 734, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 386, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 239, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 7, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2659, "impact_of_loft_insulation": -548, "impact_of_solid_wall_insulation": -4700, "space_heating_existing_dwelling": 12108}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 82, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200105791, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA8 8SH", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "EDGWARE", "built_form": 1, "created_at": "2018-09-27 09:04:46.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "169, Springwood Crescent", "assessment_type": "RdSAP", "completion_date": "2018-09-27", "inspection_date": "2018-09-26", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 5.6}, "total_floor_area": 28, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-09-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.992, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 494, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 25, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 229, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 57}], "co2_emissions_potential": 2.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 27, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 261, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 209, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 124, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1390, "space_heating_existing_dwelling": 3362}, "energy_consumption_current": 536, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 465, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 91, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 72533506, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "LS1 3LA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LEEDS", "built_form": 6, "created_at": "2018-04-30 03:48:57.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 28 Centaur House", "address_line_2": "91, Great George Street", "assessment_type": "RdSAP", "completion_date": "2018-04-30", "inspection_date": "2018-04-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-04-30", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "total_floor_area": {"value": 59, "quantity": "square metres"}, "party_wall_length": {"value": 26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 226, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 120, "currency": "GBP"}, "hot_water_cost_current": {"value": 193, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 152, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 88, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 122, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 89}], "hot_water_cost_potential": {"value": 163, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1914, "impact_of_solid_wall_insulation": -581, "space_heating_existing_dwelling": 1551}, "energy_consumption_current": 209, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 155, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060768063, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO33 2SG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RYDE", "built_form": 1, "created_at": "2018-08-22 07:31:50", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, Well Street", "assessment_type": "RdSAP", "completion_date": "2018-08-22", "inspection_date": "2018-08-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.66, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.62, "quantity": "metres"}, "total_floor_area": {"value": 57.66, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 36.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1138, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 854, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 339, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.0, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2044, "impact_of_loft_insulation": -4048, "impact_of_cavity_insulation": -4657, "space_heating_existing_dwelling": 21742}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 166, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 90019542, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "B63 4DW", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "HALESOWEN", "built_form": 2, "created_at": "2018-01-25 17:30:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "52, Witley Avenue", "assessment_type": "RdSAP", "completion_date": "2018-01-25", "inspection_date": "2018-01-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.08, "quantity": "square metres"}, "party_wall_length": {"value": 8.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 31.08, "quantity": "square metres"}, "party_wall_length": {"value": 8.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.25, "quantity": "square metres"}, "party_wall_length": 3.85, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 937, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 44, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 514, "currency": "GBP"}, "hot_water_cost_current": {"value": 267, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 7, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 8, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 9, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 10, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 90}, {"sequence": 3, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3748, "impact_of_cavity_insulation": -482, "impact_of_solid_wall_insulation": -3149, "space_heating_existing_dwelling": 11926}, "energy_consumption_current": 461, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 137, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10000824084, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT21 1SJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHTEAD", "built_form": 2, "created_at": "2018-11-20 17:34:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16284}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Old Stede Close", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-11-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 17.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 378, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 348, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2737, "impact_of_loft_insulation": -399, "space_heating_existing_dwelling": 6002}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 74, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10008791219, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SW4 7SF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-21 12:19:09.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "24 Ferndale Road", "assessment_type": "RdSAP", "completion_date": "2018-11-21", "inspection_date": "2018-11-08", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.15, "quantity": "metres"}}, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-11-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.2935, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 40.67, "quantity": "square metres"}, "party_wall_length": {"value": 9.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.08, "quantity": "metres"}}], "wall_insulation_type": 5, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 16.25, "quantity": "square metres"}, "party_wall_length": {"value": 5.81, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 279, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 217, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 88, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1811, "impact_of_solid_wall_insulation": -934, "space_heating_existing_dwelling": 3179}, "energy_consumption_current": 172, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 83, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 128, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100000058321, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE9 6LZ", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GATESHEAD", "built_form": 2, "created_at": "2018-12-21 11:15:19.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2308, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "72, Stretford Court", "assessment_type": "RdSAP", "completion_date": "2018-12-21", "inspection_date": "2018-11-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 7, "heat_loss_corridor": 2, "unheated_corridor_length": 6.4}, "total_floor_area": 47, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 46.72, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 231, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Charging system linked to use of community heating, room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 189, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 83}}], "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1844, "impact_of_cavity_insulation": -824, "space_heating_existing_dwelling": 2597}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 153, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100040049515, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TR1 1PA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TRURO", "built_form": 3, "created_at": "2018-02-19 15:47:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16922}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "29, St. Clements Close", "assessment_type": "RdSAP", "completion_date": "2018-02-19", "inspection_date": "2018-02-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.97, "quantity": "square metres"}, "party_wall_length": {"value": 4.75, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 28.97, "quantity": "square metres"}, "party_wall_length": {"value": 4.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.47, "quantity": "square metres"}, "party_wall_length": {"value": 3.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 20.47, "quantity": "square metres"}, "party_wall_length": {"value": 3.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 692, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 527, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2094, "impact_of_loft_insulation": -443, "impact_of_cavity_insulation": -1449, "space_heating_existing_dwelling": 10284}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 88, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 217004141, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW3 1PU", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-27 17:10:05.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 950, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "6 Beaufort Gardens", "assessment_type": "RdSAP", "completion_date": "2018-09-27", "inspection_date": "2018-09-24", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 1}, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "total_floor_area": {"value": 54.28, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 7.22, "quantity": "square metres"}, "party_wall_length": {"value": 2.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 553, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 122, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 195, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 207, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 156, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2013, "impact_of_solid_wall_insulation": -1178, "space_heating_existing_dwelling": 3084}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.07r02", "energy_consumption_potential": 113, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 47092395, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE29 9NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTH SHIELDS", "built_form": 3, "created_at": "2018-03-11 17:56:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16931}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Walton Avenue", "assessment_type": "RdSAP", "completion_date": "2018-03-11", "inspection_date": "2018-03-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 124, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-03-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 390, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.01, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.78, "quantity": "metres"}, "total_floor_area": {"value": 44.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.07, "quantity": "square metres"}, "party_wall_length": 5.67, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.68, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 17.07, "quantity": "square metres"}, "party_wall_length": 5.67, "heat_loss_perimeter": {"value": 8.68, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1114, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 808, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 243, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.5, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2296, "impact_of_solid_wall_insulation": -4477, "space_heating_existing_dwelling": 18400}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 148, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10006919898, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 63% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CO9 1TL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HALSTEAD", "built_form": 1, "created_at": "2018-08-11 23:09:03.000000", "door_count": 3, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 1, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17299}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Kingsmead", "address_line_2": "Church Road", "address_line_3": "Gosfield", "assessment_type": "RdSAP", "completion_date": "2018-08-11", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 127, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-08-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 37.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 54.57, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 37.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 784, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 639, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2827, "impact_of_loft_insulation": -1118, "space_heating_existing_dwelling": 15334}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100120483233, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL4 6TY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GLOUCESTER", "built_form": 2, "created_at": "2018-11-22 15:23:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15100}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "11, Northfield Road", "assessment_type": "RdSAP", "completion_date": "2018-11-22", "inspection_date": "2018-11-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 26.6, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 276, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 281, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2394, "space_heating_existing_dwelling": 3686}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 54, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 15010388, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN3 8UW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 3, "created_at": "2018-11-14 12:35:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8517}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Farmbrook Court", "assessment_type": "RdSAP", "completion_date": "2018-11-14", "inspection_date": "2018-11-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.92, "quantity": "square metres"}, "party_wall_length": {"value": 6.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 40.91, "quantity": "square metres"}, "party_wall_length": {"value": 6.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 581, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 436, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2126, "space_heating_existing_dwelling": 8572}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 94, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 4510718968, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE1 2EQ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 4, "created_at": "2018-08-24 11:13:45.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "20 Manor Chare Apartments", "address_line_2": "Manor Chare", "assessment_type": "RdSAP", "completion_date": "2018-08-24", "inspection_date": "2018-07-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-08-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 74, "quantity": "square metres"}, "party_wall_length": {"value": 17.79, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 197, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 81, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 125, "currency": "GBP"}, "hot_water_cost_current": {"value": 206, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 88, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 139, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 88}], "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1863, "space_heating_existing_dwelling": 1312}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 135, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "B", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100061820560, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RH12 4LS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORSHAM", "built_form": 2, "created_at": "2018-06-29 20:21:03.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "4, Shepherds Way", "assessment_type": "RdSAP", "completion_date": "2018-06-29", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.6, "quantity": "square metres"}, "party_wall_length": {"value": 10.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 346, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.8, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2601, "space_heating_existing_dwelling": 6149}, "energy_consumption_current": 286, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 77, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 12012878, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W3 9SD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 5, "created_at": "2018-08-31 15:08:40.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "17, West Lodge Court", "address_line_2": "Uxbridge Road", "assessment_type": "RdSAP", "completion_date": "2018-08-31", "inspection_date": "2018-08-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-08-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 44.83, "quantity": "square metres"}, "party_wall_length": {"value": 1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 457, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 385, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.1, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1619, "impact_of_solid_wall_insulation": -1540, "space_heating_existing_dwelling": 7314}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 268, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100120784561, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX25 5TS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BICESTER", "built_form": 2, "created_at": "2018-11-20 14:55:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 506, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Warm air, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "14, Roper Road", "address_line_2": "Upper Heyford", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-11-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 86.06, "quantity": "square metres"}, "party_wall_length": {"value": 8.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.16, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 613, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 465, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a31,250 - \u00a32,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 131, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 179, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2630, "space_heating_existing_dwelling": 8838}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10010506350, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV22 7EL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUGBY", "built_form": 3, "created_at": "2018-05-16 12:11:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "56, Farnborough Avenue", "assessment_type": "RdSAP", "completion_date": "2018-05-16", "inspection_date": "2018-02-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.8, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 46.8, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 351, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 351, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.1, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2206, "space_heating_existing_dwelling": 5379}, "energy_consumption_current": 135, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 62, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10023288188, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG10 1EH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 3, "created_at": "2018-12-24 11:41:46.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "1a, Oxford Street", "address_line_3": "Long Eaton", "assessment_type": "RdSAP", "completion_date": "2018-12-24", "inspection_date": "2018-12-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-12-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 4, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.26, "quantity": "square metres"}, "party_wall_length": {"value": 5.27, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 16.16, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 187, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 144, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 170, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1798, "space_heating_existing_dwelling": 1619}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 187, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 83122233, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD11 2NL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRADFORD", "built_form": 2, "created_at": "2018-07-10 10:39:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17145}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Kingsley Crescent", "address_line_2": "Birkenshaw", "assessment_type": "RdSAP", "completion_date": "2018-07-10", "inspection_date": "2018-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.53, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.56, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 37.53, "quantity": "square metres"}, "party_wall_length": {"value": 7.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.56, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 498, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 451, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1760, "space_heating_existing_dwelling": 8756}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 110, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 43021255, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 36% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CF82 8AH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HENGOED", "built_form": 2, "created_at": "2018-07-03 13:48:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "24, Woodfield Terrace", "address_line_2": "Tir-y-Berth", "assessment_type": "RdSAP", "completion_date": "2018-07-03", "inspection_date": "2018-07-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.55, "quantity": "square metres"}, "party_wall_length": {"value": 5.72, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 38.55, "quantity": "square metres"}, "party_wall_length": {"value": 5.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 913, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 633, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1891, "impact_of_loft_insulation": -3578, "impact_of_cavity_insulation": -3343, "space_heating_existing_dwelling": 17001}, "energy_consumption_current": 382, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 176, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200002627908, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HR9 7AN", "hot_water": {"description": "Gas multipoint", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ROSS-ON-WYE", "built_form": 2, "created_at": "2018-05-16 16:26:24.000000", "door_count": 0, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 402, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.5, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 4 Rose Bank", "address_line_2": "2, Cantilupe Road", "assessment_type": "RdSAP", "completion_date": "2018-05-16", "inspection_date": "2018-05-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.26}, "total_floor_area": 39, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.354, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 260, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "total_floor_area": {"value": 39.2, "quantity": "square metres"}, "party_wall_length": {"value": 3.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 1073, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 29, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 285, "currency": "GBP"}, "hot_water_cost_current": {"value": 69, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 536, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.2, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 196, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 136, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1111, "impact_of_solid_wall_insulation": -3854, "space_heating_existing_dwelling": 7030}, "energy_consumption_current": 621, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r04", "energy_consumption_potential": 181, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100012718183, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [11]}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M6 5NL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SALFORD", "built_form": 3, "created_at": "2018-01-27 16:38:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10036}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Wall Street", "assessment_type": "RdSAP", "completion_date": "2018-01-27", "inspection_date": "2018-01-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 121, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-01-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.94, "quantity": "square metres"}, "party_wall_length": {"value": 8.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.83, "quantity": "metres"}, "total_floor_area": {"value": 50.59, "quantity": "square metres"}, "party_wall_length": {"value": 13.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 543, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 543, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2290, "space_heating_existing_dwelling": 9659}, "energy_consumption_current": 152, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 102, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100070581191, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B75 7QT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUTTON COLDFIELD", "built_form": 4, "created_at": "2018-09-05 09:30:42.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "7, Chadwick Road", "assessment_type": "RdSAP", "completion_date": "2018-09-05", "inspection_date": "2018-09-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.72, "quantity": "square metres"}, "party_wall_length": {"value": 6.41, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 46.12, "quantity": "square metres"}, "party_wall_length": {"value": 14.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 830, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 713, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1946, "impact_of_loft_insulation": -3995, "impact_of_solid_wall_insulation": -1137, "space_heating_existing_dwelling": 15708}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 183, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100061349647, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "KT17 2PS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "EPSOM", "built_form": 2, "created_at": "2018-09-06 21:09:11.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "15, Beaufort Way", "assessment_type": "RdSAP", "completion_date": "2018-09-06", "inspection_date": "2018-09-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.31, "quantity": "square metres"}, "party_wall_length": {"value": 9.29, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 22.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 469, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 247, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4919, "impact_of_solid_wall_insulation": -2349, "space_heating_existing_dwelling": 6863}, "energy_consumption_current": 370, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 78, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100021268236, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HA2 6HG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 2, "created_at": "2018-02-02 08:18:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17805}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Headstone Lane", "assessment_type": "RdSAP", "completion_date": "2018-02-02", "inspection_date": "2018-02-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-02-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.54, "quantity": "square metres"}, "party_wall_length": {"value": 7.91, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 50.54, "quantity": "square metres"}, "party_wall_length": {"value": 7.91, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.81, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 6.81, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 745, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 144, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 493, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 174, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2940, "impact_of_loft_insulation": -575, "impact_of_cavity_insulation": -832, "impact_of_solid_wall_insulation": -3987, "space_heating_existing_dwelling": 14134}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 90, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031517988, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG7 5NT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-02-06 11:56:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15834}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "25a, Beckenham Road", "assessment_type": "RdSAP", "completion_date": "2018-02-06", "inspection_date": "2018-02-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 31.75, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 28.5, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 291, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 207, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1863, "impact_of_solid_wall_insulation": -1879, "space_heating_existing_dwelling": 3817}, "energy_consumption_current": 168, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 117, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100050386067, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HG1 4PZ", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROGATE", "built_form": 5, "created_at": "2018-07-10 23:51:38.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "2 Camwal Terrace", "assessment_type": "RdSAP", "completion_date": "2018-07-10", "inspection_date": "2018-07-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 27, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-07-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 27.18, "quantity": "square metres"}, "party_wall_length": {"value": 11.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 261, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 24, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 261, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.6, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1659, "space_heating_existing_dwelling": 3143}, "energy_consumption_current": 334, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 334, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10034139661, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH10 1AQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CRAWLEY", "built_form": 4, "created_at": "2018-07-13 07:55:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Flat 104 Rampling Court", "address_line_2": "Commonwealth Drive", "assessment_type": "RdSAP", "completion_date": "2018-07-13", "inspection_date": "2018-07-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 94, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-07-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.05, "quantity": "square metres"}, "party_wall_length": {"value": 17.62, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 10.68, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 47.05, "quantity": "square metres"}, "party_wall_length": {"value": 17.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 249, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 82, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 249, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2209, "space_heating_existing_dwelling": 3018}, "energy_consumption_current": 100, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 100, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "B", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 18, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 40013854, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "L35 5AJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRESCOT", "built_form": 3, "created_at": "2018-05-14 16:35:48.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8587}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Edward Road", "address_line_2": "Whiston", "assessment_type": "RdSAP", "completion_date": "2018-05-14", "inspection_date": "2018-05-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.92, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 27.18, "quantity": "square metres"}, "party_wall_length": {"value": 6.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.77, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 578, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 404, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 9, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 49, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1993, "impact_of_loft_insulation": -584, "impact_of_cavity_insulation": -627, "space_heating_existing_dwelling": 8492}, "energy_consumption_current": 284, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 91, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100020952415, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE3 7PX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-06-20 23:06:15.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "88, Combe Avenue", "assessment_type": "RdSAP", "completion_date": "2018-06-20", "inspection_date": "2018-06-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.83, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.83, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 643, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 316, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2101, "impact_of_solid_wall_insulation": -3497, "space_heating_existing_dwelling": 11859}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 57, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100011393123, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M28 1HY", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-03-27 16:51:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "122, Vicars Hall Lane", "address_line_2": "Worsley", "assessment_type": "RdSAP", "completion_date": "2018-03-27", "inspection_date": "2018-03-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.9, "wall_dry_lined": "N", "wall_thickness": 240, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.92, "quantity": "square metres"}, "party_wall_length": {"value": 16.14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 32.92, "quantity": "square metres"}, "party_wall_length": {"value": 16.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.89, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 823, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 295, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 6, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 7, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 8, "typical_saving": {"value": 249, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 10, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 215, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 130, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 245, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3406, "impact_of_loft_insulation": -793, "impact_of_cavity_insulation": -1015, "impact_of_solid_wall_insulation": -914, "space_heating_existing_dwelling": 9115}, "energy_consumption_current": 457, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 107, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10090616108, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S7 2AB", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 6, "created_at": "2018-03-28 13:55:06.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 15", "address_line_2": "451 Abbey Lane", "assessment_type": "RdSAP", "completion_date": "2018-03-28", "inspection_date": "2018-03-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-03-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 46.77, "quantity": "square metres"}, "party_wall_length": {"value": 18.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 429, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, programmer and TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 401, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.5, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1845, "impact_of_loft_insulation": -3178, "impact_of_cavity_insulation": -555, "space_heating_existing_dwelling": 6051}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 299, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100110693481, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CA11 7QY", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PENRITH", "built_form": 3, "created_at": "2018-03-31 14:30:48.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 9, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "57 Wordsworth Street", "assessment_type": "RdSAP", "completion_date": "2018-03-31", "inspection_date": "2018-03-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-03-31", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 510, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 48.75, "quantity": "square metres"}, "party_wall_length": {"value": 6.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 935, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 279, "currency": "GBP"}, "hot_water_cost_current": {"value": 207, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 477, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 236, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 325, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 275, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1811, "impact_of_solid_wall_insulation": -3375, "space_heating_existing_dwelling": 6559}, "energy_consumption_current": 544, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 337, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 92, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200002614678, "roofs": [{"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HR6 8HS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEOMINSTER", "built_form": 3, "created_at": "2018-04-01 09:59:48.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17125}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2, Sandpits", "assessment_type": "RdSAP", "completion_date": "2018-04-01", "inspection_date": "2018-03-30", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.28, "quantity": "square metres"}, "party_wall_length": {"value": 5.78, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 37.28, "quantity": "square metres"}, "party_wall_length": {"value": 5.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 10.43, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 830, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 548, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2751, "impact_of_loft_insulation": -4320, "space_heating_existing_dwelling": 14217}, "energy_consumption_current": 290, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 117, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100081010466, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LU3 2RB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LUTON", "built_form": 1, "created_at": "2018-09-07 17:57:11.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "21 Anvil Court", "address_line_2": "Marsh Road", "assessment_type": "RdSAP", "completion_date": "2018-09-07", "inspection_date": "2018-09-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 9.52}, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 22.848, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 56.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.94, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 317, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 287, "currency": "GBP"}, "hot_water_cost_current": {"value": 71, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1605, "impact_of_loft_insulation": -681, "impact_of_cavity_insulation": -400, "space_heating_existing_dwelling": 4637}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 160, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100021386603, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM7 8DS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "ROMFORD", "built_form": 4, "created_at": "2018-09-18 17:27:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "265, Mawney Road", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 48, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 24, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 47, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 311, "currency": "GBP"}, "hot_water_cost_current": {"value": 293, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 8, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.6, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 90, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4015, "space_heating_existing_dwelling": 4993}, "energy_consumption_current": 422, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 70, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100081196801, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 35% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LU6 3QE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DUNSTABLE", "built_form": 2, "created_at": "2018-02-10 14:59:36.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15458}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Ulverston Road", "assessment_type": "RdSAP", "completion_date": "2018-02-10", "inspection_date": "2018-02-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.809, "quantity": "square metres"}, "party_wall_length": {"value": 6.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.709, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.318, "quantity": "metres"}, "total_floor_area": {"value": 33.809, "quantity": "square metres"}, "party_wall_length": {"value": 6.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.992, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.283, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.949, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.333, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 35, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 844, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 616, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 93, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 120, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 7, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2686, "impact_of_loft_insulation": -1836, "impact_of_cavity_insulation": -2196, "space_heating_existing_dwelling": 12951}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 143, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100091388955, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 72% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IP24 2NF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "THETFORD", "built_form": 1, "created_at": "2018-02-09 14:20:52", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1874}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Yew Tree House", "address_line_2": "The Street", "address_line_3": "Barnham", "assessment_type": "RdSAP", "completion_date": "2018-02-09", "inspection_date": "2018-02-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 191, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 10, "pvc_window_frames": "false", "registration_date": "2018-02-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 10.9, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 88.72, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 49.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 91.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 42.94, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 72, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 937, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 135, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 781, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}], "co2_emissions_potential": 6.3, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 105, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 109, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2868, "impact_of_loft_insulation": -850, "space_heating_existing_dwelling": 18843}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["N", "U"], "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 142, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100080969306, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 9% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "EN6 1JA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POTTERS BAR", "built_form": 2, "created_at": "2018-07-17 16:46:03.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 17823}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "8, Heronfield", "assessment_type": "RdSAP", "completion_date": "2018-07-17", "inspection_date": "2018-07-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 27.17, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "D"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.58, "quantity": "square metres"}, "party_wall_length": {"value": 9.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 9, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1086, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.5, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 590, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 373, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 63}}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2902, "impact_of_loft_insulation": -391, "impact_of_cavity_insulation": -1215, "space_heating_existing_dwelling": 16484}, "energy_consumption_current": 383, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 137, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100100611267, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 77% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA10 6NB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEATH", "built_form": 4, "created_at": "2018-07-17 19:20:21.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, High Street", "address_line_2": "Skewen", "assessment_type": "RdSAP", "completion_date": "2018-07-17", "inspection_date": "2018-07-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.66, "quantity": "square metres"}, "party_wall_length": {"value": 14.08, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.11, "quantity": "metres"}, "total_floor_area": {"value": 32.66, "quantity": "square metres"}, "party_wall_length": {"value": 14.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.73, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 11.73, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 77, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 647, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 472, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2178, "impact_of_cavity_insulation": -1175, "impact_of_solid_wall_insulation": -873, "space_heating_existing_dwelling": 8699}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100060597855, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 36% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SO22 5NL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WINCHESTER", "built_form": 2, "created_at": "2018-04-05 11:51:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Bradley Peak", "assessment_type": "RdSAP", "completion_date": "2018-04-05", "inspection_date": "2018-04-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.27, "quantity": "square metres"}, "party_wall_length": {"value": 5.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 43.78, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26.48, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 604, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 541, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2871, "impact_of_loft_insulation": -455, "space_heating_existing_dwelling": 8711}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10013308581, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT9 2BA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARGATE", "built_form": 2, "created_at": "2018-05-24 00:31:27.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15274}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 10", "address_line_2": "22, Athelstan Road", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-16", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.7, "quantity": "metres"}}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 440, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.326, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 190, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 33.83, "quantity": "square metres"}, "party_wall_length": {"value": 3.96, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 440, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 9.32, "quantity": "square metres"}, "party_wall_length": {"value": 3.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 595, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 538, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 51}], "co2_emissions_potential": 2.9, "energy_rating_potential": 56, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1593, "impact_of_loft_insulation": -3387, "impact_of_solid_wall_insulation": -497, "space_heating_existing_dwelling": 9657}, "energy_consumption_current": 423, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 384, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 51, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090080865, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PE13 1QA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WISBECH", "built_form": 4, "created_at": "2018-08-24 18:01:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Horseshoe Terrace", "assessment_type": "RdSAP", "completion_date": "2018-08-24", "inspection_date": "2018-08-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.314, "quantity": "square metres"}, "party_wall_length": {"value": 7.651, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.329, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.323, "quantity": "metres"}, "total_floor_area": {"value": 24.314, "quantity": "square metres"}, "party_wall_length": {"value": 7.651, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.329, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.227, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.86, "quantity": "square metres"}, "party_wall_length": {"value": 2.896, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.896, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 4.86, "quantity": "square metres"}, "party_wall_length": {"value": 2.896, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.574, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 170, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.227, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.86, "quantity": "square metres"}, "party_wall_length": {"value": 2.896, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.574, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1573, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 23, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 580, "currency": "GBP"}, "hot_water_cost_current": {"value": 213, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 25, "environmental_impact_rating": 28}, {"sequence": 2, "typical_saving": {"value": 477, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 44}, {"sequence": 5, "typical_saving": {"value": 422, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 42}, {"sequence": 6, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 46}, {"sequence": 7, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 56}], "co2_emissions_potential": 3.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 582, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 458, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1830, "impact_of_loft_insulation": -1684, "impact_of_solid_wall_insulation": -3503, "space_heating_existing_dwelling": 11073}, "energy_consumption_current": 654, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 85, "calculation_software_version": "2.0.x", "energy_consumption_potential": 308, "environmental_impact_current": 26, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "F", "environmental_impact_potential": 56, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 111, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45012245, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SR1 1LN", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2018-08-28 10:55:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "32 Frederick Street", "assessment_type": "RdSAP", "completion_date": "2018-08-28", "inspection_date": "2018-08-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.3, "quantity": "metres"}}, "total_floor_area": 18, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.04, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 18.06, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 90, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 120, "currency": "GBP"}, "hot_water_cost_current": {"value": 256, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 20, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 195, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1546, "space_heating_existing_dwelling": 544}, "energy_consumption_current": 395, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 215, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100070012725, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WV7 3DH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 2, "created_at": "2018-11-06 14:26:43.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "40, Weston Road", "address_line_2": "Albrighton", "assessment_type": "RdSAP", "completion_date": "2018-11-06", "inspection_date": "2018-11-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-11-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.4, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36.4, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1054, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 860, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.3, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 56}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2313, "impact_of_loft_insulation": -3056, "impact_of_cavity_insulation": -2248, "space_heating_existing_dwelling": 16793}, "energy_consumption_current": 348, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 211, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 200003681836, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME15 6TJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDSTONE", "built_form": 2, "created_at": "2018-11-02 15:54:27.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "62, Sheals Crescent", "assessment_type": "RdSAP", "completion_date": "2018-11-02", "inspection_date": "2018-11-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-11-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.15, "quantity": "square metres"}, "party_wall_length": {"value": 12.36, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.28, "quantity": "square metres"}, "party_wall_length": {"value": 11.21, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 821, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 568, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2619, "impact_of_loft_insulation": -3697, "impact_of_solid_wall_insulation": -4900, "space_heating_existing_dwelling": 15072}, "energy_consumption_current": 326, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 146, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200106882, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N3 1SH", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-07 08:37:28.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 506, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Warm air, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "19, St. Michael's Close", "assessment_type": "RdSAP", "completion_date": "2018-11-07", "inspection_date": "2018-11-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 7.56}, "total_floor_area": 47, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-11-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.388, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.57, "quantity": "square metres"}, "party_wall_length": {"value": 12.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 273, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 201, "currency": "GBP"}, "hot_water_cost_current": {"value": 190, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "2,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3141, "impact_of_solid_wall_insulation": -565, "space_heating_existing_dwelling": 3108}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 165, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10013790229, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BN18 9FF", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "ARUNDEL", "built_form": 4, "created_at": "2018-06-26 16:51:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230001, "number_of_heaters": 5, "high_heat_retention": "false"}, {"index_number": 230002, "number_of_heaters": 3, "high_heat_retention": "false"}, {"index_number": 230003, "number_of_heaters": 1, "high_heat_retention": "false"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Newland Gardens", "address_line_2": "Amberley", "assessment_type": "RdSAP", "completion_date": "2018-06-26", "inspection_date": "2018-02-06", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 108, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.42, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 61.42, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 676, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 154, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 568, "currency": "GBP"}, "hot_water_cost_current": {"value": 160, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a380", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 347, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 64}], "co2_emissions_potential": 3.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2109, "space_heating_existing_dwelling": 8091}, "energy_consumption_current": 315, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 177, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100080858711, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "AL1 1TH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. ALBANS", "built_form": 1, "created_at": "2018-09-19 19:10:05", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10114}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "3, Mile House Lane", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-19", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 229, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 10, "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.68, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 45.67, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 20.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.98, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 38.98, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 22.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.99, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.51, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.26, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 16.92, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 1379, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 213, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1274, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a3100", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "co2_emissions_potential": 5.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 106, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 145, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3018, "impact_of_loft_insulation": -5158, "impact_of_cavity_insulation": -2711, "space_heating_existing_dwelling": 25810}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 153, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10023043830, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M14 7BA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "MANCHESTER", "built_form": 3, "created_at": "2018-07-23 10:52:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 34 Parkside", "address_line_2": "193, Hart Road", "assessment_type": "RdSAP", "completion_date": "2018-07-23", "inspection_date": "2018-07-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.8, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.58, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 63.45, "quantity": "square metres"}, "party_wall_length": {"value": 11.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 211, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 172, "currency": "GBP"}, "hot_water_cost_current": {"value": 156, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 156, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1963, "space_heating_existing_dwelling": 2306}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 203, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100030032489, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE7 6BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILKESTON", "built_form": 1, "created_at": "2018-04-05 13:03:14.000000", "door_count": 1, "glazed_area": 4, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 17553}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 7.2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 1.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 7, "window_area": {"value": 0.9, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 7, "window_area": {"value": 0.8, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 5.6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 2.7, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 2.4, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "53, Church Lane", "address_line_2": "Horsley Woodhouse", "assessment_type": "RdSAP", "completion_date": "2018-04-05", "inspection_date": "2018-04-05", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 96, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-04-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 55.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 683, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 566, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2901, "impact_of_loft_insulation": -718, "impact_of_cavity_insulation": -225, "space_heating_existing_dwelling": 12129}, "energy_consumption_current": 242, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 133, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100061827218, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RH20 1LT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "PULBOROUGH", "built_form": 2, "created_at": "2018-04-13 14:27:45.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "2, Brookland Way", "address_line_2": "Coldwaltham", "assessment_type": "RdSAP", "completion_date": "2018-04-13", "inspection_date": "2018-04-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 44, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-04-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 734, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 331, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 30}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 39}, {"sequence": 4, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 45}, {"sequence": 5, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 45}, {"sequence": 6, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 51}, {"sequence": 7, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 57}, {"sequence": 8, "typical_saving": {"value": 330, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 207, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 141, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1642, "impact_of_loft_insulation": -603, "impact_of_cavity_insulation": -1624, "space_heating_existing_dwelling": 8210}, "energy_consumption_current": 715, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 209, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 121, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100050550437, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "YO10 3BY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 4, "created_at": "2018-04-18 07:14:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8587}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "63, Farrar Street", "assessment_type": "RdSAP", "completion_date": "2018-04-18", "inspection_date": "2018-04-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.99, "quantity": "square metres"}, "party_wall_length": {"value": 16.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 31.99, "quantity": "square metres"}, "party_wall_length": {"value": 16.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.78, "quantity": "square metres"}, "party_wall_length": {"value": 2.98, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.92, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 532, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1998, "impact_of_solid_wall_insulation": -1023, "space_heating_existing_dwelling": 6364}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 83, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10070085212, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE45 1BB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BAKEWELL", "built_form": 2, "created_at": "2018-04-09 15:04:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8109}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Cramond", "address_line_2": "Wyedale Drive", "assessment_type": "RdSAP", "completion_date": "2018-04-09", "inspection_date": "2018-04-04", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.575, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.685, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 780, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 519, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 117, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1895, "impact_of_loft_insulation": -384, "impact_of_cavity_insulation": -2040, "space_heating_existing_dwelling": 10941}, "energy_consumption_current": 366, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 145, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110211336, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "TS15 9RN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YARM", "built_form": 1, "created_at": "2018-05-24 08:47:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 4046}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Glaisdale Road", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-23", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.1, "wall_dry_lined": "N", "wall_thickness": 370, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.06, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 27.41, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 50.06, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 31.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.91, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.01, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 873, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 699, "currency": "GBP"}, "hot_water_cost_current": {"value": 235, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 8, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 253, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4239, "impact_of_loft_insulation": -768, "impact_of_cavity_insulation": -554, "space_heating_existing_dwelling": 12082}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 131, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10022882927, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S70 2DG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNSLEY", "built_form": 3, "created_at": "2018-07-24 11:52:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "3, Sackville Heights", "assessment_type": "RdSAP", "completion_date": "2018-07-24", "inspection_date": "2018-07-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 450, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.338, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.575, "quantity": "square metres"}, "party_wall_length": {"value": 10.403, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.639, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 409, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 262, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1803, "impact_of_solid_wall_insulation": -2320, "space_heating_existing_dwelling": 6208}, "energy_consumption_current": 275, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 175, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100020953749, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SE9 5NP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 1, "created_at": "2018-09-23 12:37:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 15426}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50, Court Road", "assessment_type": "RdSAP", "completion_date": "2018-09-23", "inspection_date": "2018-09-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 336, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 10, "pvc_window_frames": "false", "registration_date": "2018-09-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 65.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 56.7, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 54.9, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 19, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 3052, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 17.5, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 238, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1853, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 183, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 678, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3100", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 60}], "co2_emissions_potential": 9.6, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 136, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1817, "impact_of_loft_insulation": -5924, "impact_of_solid_wall_insulation": -14725, "space_heating_existing_dwelling": 63722}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 162, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "E", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 72249421, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LS15 7UD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 3, "created_at": "2018-06-04 20:31:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Long Field Drive", "address_line_2": "Halton", "assessment_type": "RdSAP", "completion_date": "2018-06-04", "inspection_date": "2018-06-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.05, "quantity": "square metres"}, "party_wall_length": {"value": 7.17, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 29.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.17, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 441, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 409, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1936, "space_heating_existing_dwelling": 6522}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 118, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 12028011, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "UB2 5PA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHALL", "built_form": 4, "created_at": "2018-06-25 10:25:02.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17816}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "6, Montague Waye", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.87, "quantity": "square metres"}, "party_wall_length": {"value": 18.89, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 46.78, "quantity": "square metres"}, "party_wall_length": {"value": 19.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.09, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.68, "quantity": "square metres"}, "party_wall_length": {"value": 1.61, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 4.52, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 726, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 601, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2229, "impact_of_loft_insulation": -3654, "impact_of_solid_wall_insulation": -1998, "space_heating_existing_dwelling": 13689}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "3.05r03", "energy_consumption_potential": 133, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100070119490, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true"}, "lighting": {"description": {"value": "Low energy lighting in 9% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "B46 1PE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-03-06 15:03:55.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8844}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "64, George Road", "address_line_2": "Water Orton", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-03-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.262, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.33, "quantity": "square metres"}, "party_wall_length": {"value": 6.02, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.42, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.349, "quantity": "metres"}, "total_floor_area": {"value": 40.33, "quantity": "square metres"}, "party_wall_length": {"value": 6.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.83, "quantity": "square metres"}, "party_wall_length": {"value": 6.02, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 9, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 505, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 467, "currency": "GBP"}, "hot_water_cost_current": {"value": 184, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3485, "space_heating_existing_dwelling": 7789}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 102, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10090431928, "roofs": [{"description": "Pitched, 25 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B44 8HX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2018-09-24 17:46:59.000000", "door_count": 2, "glazed_area": 3, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18250}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "103a, Burnham Road", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-24", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.73, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 15.73, "quantity": "square metres"}, "party_wall_length": {"value": 4.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 50.38, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 648, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 404, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1747, "impact_of_loft_insulation": -2262, "impact_of_solid_wall_insulation": -3420, "space_heating_existing_dwelling": 12178}, "energy_consumption_current": 261, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 160, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 148035579, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EN7 5AP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALTHAM CROSS", "built_form": 4, "created_at": "2018-10-18 10:20:57.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Temple Close", "address_line_2": "Cheshunt", "assessment_type": "RdSAP", "completion_date": "2018-10-18", "inspection_date": "2018-10-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.65, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.53, "quantity": "square metres"}, "party_wall_length": {"value": 7.58, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.43, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 51.37, "quantity": "square metres"}, "party_wall_length": {"value": 7.58, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.43, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.33, "quantity": "square metres"}, "party_wall_length": {"value": 7.58, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.63, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 607, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 439, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2100, "impact_of_solid_wall_insulation": -1110, "space_heating_existing_dwelling": 11144}, "energy_consumption_current": 181, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 73, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100031827992, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WV5 7HA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOLVERHAMPTON", "built_form": 4, "created_at": "2018-02-26 21:07:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17550}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2 John Rudge Court", "address_line_2": "Post Office Road", "address_line_3": "Seisdon", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.14, "quantity": "square metres"}, "party_wall_length": {"value": 9.29, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 33.14, "quantity": "square metres"}, "party_wall_length": {"value": 9.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 420, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 317, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2684, "impact_of_loft_insulation": -505, "impact_of_cavity_insulation": -1398, "space_heating_existing_dwelling": 6855}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 66, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090157381, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Full secondary glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CB1 9YS", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "CAMBRIDGE", "built_form": 4, "created_at": "2018-07-31 16:46:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "5, Speedwell Close", "assessment_type": "RdSAP", "completion_date": "2018-07-31", "inspection_date": "2018-07-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 6.62}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-31", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.888, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.76, "quantity": "square metres"}, "party_wall_length": {"value": 8.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 510, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 76, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 316, "currency": "GBP"}, "hot_water_cost_current": {"value": 185, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 229, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 156, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 138, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1970, "space_heating_existing_dwelling": 5353}, "energy_consumption_current": 379, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r05", "energy_consumption_potential": 259, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 64, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10006525612, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 85% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LN4 4HD", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LINCOLN", "built_form": 1, "created_at": "2018-04-25 10:40:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8924}], "immersion_heating_type": 2, "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "5, Carr Gate", "address_line_2": "Billinghay", "assessment_type": "RdSAP", "completion_date": "2018-04-25", "inspection_date": "2018-04-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 7, "registration_date": "2018-04-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, coal", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 56.31, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.61, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 514, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 485, "currency": "GBP"}, "hot_water_cost_current": {"value": 333, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 256, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 85}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2068, "space_heating_existing_dwelling": 9363}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 97, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10003758691, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BB11 4HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURNLEY", "built_form": 3, "created_at": "2018-06-14 12:05:04.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Second Floor Flat", "address_line_2": "175, Manchester Road", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 96, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 26.02, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 96.37, "quantity": "square metres"}, "party_wall_length": {"value": 5.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 48.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1288, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 46, "lighting_cost_current": {"value": 137, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 896, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 400, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}], "co2_emissions_potential": 5.0, "energy_rating_potential": 62, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2110, "impact_of_loft_insulation": -8727, "impact_of_solid_wall_insulation": -9982, "space_heating_existing_dwelling": 26366}, "energy_consumption_current": 433, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 296, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010799737, "roofs": [{"description": {"value": "Pitched, 400 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 7% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "FY2 0UU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BLACKPOOL", "built_form": 3, "created_at": "2018-03-26 13:56:52.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2502, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 506, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Warm air, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "71, Edmonton Place", "assessment_type": "RdSAP", "completion_date": "2018-03-26", "inspection_date": "2018-03-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-03-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48.8, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 7, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 329, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 260, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a31,250 - \u00a32,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.7, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 85, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2884, "space_heating_existing_dwelling": 3299}, "energy_consumption_current": 273, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 195, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100040393944, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in 53% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EX20 1EA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OKEHAMPTON", "built_form": 4, "created_at": "2018-10-01 17:31:44.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5931}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "33, Station Road", "assessment_type": "RdSAP", "completion_date": "2018-10-01", "inspection_date": "2018-10-01", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 169, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-10-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 455, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 30.18, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.88, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.29, "quantity": "square metres"}, "party_wall_length": {"value": 17.48, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 47.29, "quantity": "square metres"}, "party_wall_length": {"value": 17.48, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 440, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.62, "quantity": "metres"}, "total_floor_area": {"value": 20.22, "quantity": "square metres"}, "party_wall_length": {"value": 5.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 140, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.54, "quantity": "square metres"}, "party_wall_length": {"value": 1.33, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1870, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 47, "lighting_cost_current": {"value": 135, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 3, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1076, "currency": "GBP"}, "hot_water_cost_current": {"value": 180, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 253, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 5.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 402, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3171, "impact_of_loft_insulation": -1581, "impact_of_solid_wall_insulation": -4831, "space_heating_existing_dwelling": 27929}, "energy_consumption_current": 353, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "3.07r02", "energy_consumption_potential": 157, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100030144897, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG10 4JB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-09-30 14:38:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "323, Bennett Street", "address_line_2": "Long Eaton", "assessment_type": "RdSAP", "completion_date": "2018-09-30", "inspection_date": "2018-09-27", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.97, "wall_dry_lined": "Y", "wall_thickness": 270, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.25, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 0.89, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 1.9, "quantity": "metres"}, "total_floor_area": {"value": 0.89, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.83, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 0.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 726, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 486, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 197, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2100, "impact_of_cavity_insulation": -456, "impact_of_solid_wall_insulation": -4072, "space_heating_existing_dwelling": 12422}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 108, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10093594003, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N15 3HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-04-30 12:33:15.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "42b Park Road", "assessment_type": "RdSAP", "completion_date": "2018-04-30", "inspection_date": "2018-04-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 50, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-04-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 245, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 245, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 92, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.3, "energy_rating_potential": 92, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1740, "space_heating_existing_dwelling": 2969}, "energy_consumption_current": 153, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 25, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": null, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CO14 8EQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALTON ON THE NAZE", "built_form": 4, "created_at": "2018-04-24 17:16:17.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16632}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "11 Crescent Road", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-23", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 6.62}, "total_floor_area": 44, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.3374, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 180, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 34.55, "quantity": "square metres"}, "party_wall_length": {"value": 11.73, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.87, "quantity": "metres"}, "total_floor_area": {"value": 9.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 407, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 216, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 67, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 105, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1766, "impact_of_solid_wall_insulation": -2607, "space_heating_existing_dwelling": 6083}, "energy_consumption_current": 297, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 153, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050043182, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Roof room(s), insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU16 5RN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COTTINGHAM", "built_form": 4, "created_at": "2018-04-24 06:32:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "258, Northgate", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 17.8, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "250mm"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 29.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 749, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 599, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2165, "impact_of_loft_insulation": -1038, "impact_of_cavity_insulation": -713, "impact_of_solid_wall_insulation": -1202, "space_heating_existing_dwelling": 12662}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 138, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 41007116, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L21 8JY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-05-26 16:14:21.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16930}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "3, Beechwood Road", "address_line_2": "Litherland", "assessment_type": "RdSAP", "completion_date": "2018-05-26", "inspection_date": "2018-05-24", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.67, "quantity": "metres"}, "total_floor_area": {"value": 32, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6, "quantity": "square metres"}, "party_wall_length": {"value": 3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 409, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1873, "impact_of_loft_insulation": -2412, "impact_of_solid_wall_insulation": -1522, "space_heating_existing_dwelling": 8438}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 105, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100050383287, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HG2 7PF", "hot_water": {"description": "Gas multipoint", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HARROGATE", "built_form": 4, "created_at": "2018-06-13 18:59:52.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "23, Avenue Street", "assessment_type": "RdSAP", "completion_date": "2018-06-13", "inspection_date": "2018-06-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 9.77, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.92, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.62, "quantity": "metres"}, "total_floor_area": {"value": 21.92, "quantity": "square metres"}, "party_wall_length": {"value": 15.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.38, "quantity": "square metres"}, "party_wall_length": {"value": 2.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1118, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 396, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 363, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 238, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 115, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 239, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1335, "impact_of_loft_insulation": -178, "impact_of_solid_wall_insulation": -1085, "space_heating_existing_dwelling": 13638}, "energy_consumption_current": 772, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 112, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 132, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 25037933, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK3 7DZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MILTON KEYNES", "built_form": 2, "created_at": "2018-01-05 08:25:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "205, Whaddon Way", "address_line_2": "Bletchley", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.19, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 43.69, "quantity": "square metres"}, "party_wall_length": {"value": 6.58, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 703, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 489, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2805, "impact_of_loft_insulation": -584, "impact_of_cavity_insulation": -2866, "space_heating_existing_dwelling": 11624}, "energy_consumption_current": 292, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 116, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200001214691, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE25 6UX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-10-06 18:46:05.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8214}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Ground Floor Flat", "address_line_2": "208 Whitehorse Lane", "assessment_type": "RdSAP", "completion_date": "2018-10-06", "inspection_date": "2018-10-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.31, "quantity": "square metres"}, "party_wall_length": {"value": 19.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 394, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 205, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1658, "impact_of_solid_wall_insulation": -2068, "space_heating_existing_dwelling": 5297}, "energy_consumption_current": 263, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 136, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10002481918, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, with internal insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO18 0RX", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}, "post_town": "CHICHESTER", "built_form": 2, "created_at": "2018-09-24 21:37:43", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 31, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 31, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2306, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "131", "address_line_2": "West Dean", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [2], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.85, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.07, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 44.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.07, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 469, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Charging system linked to use of community heating, programmer and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 353, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 93}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 93}, {"sequence": 4, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 94}, {"sequence": 5, "typical_saving": {"value": 337, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 103}], "co2_emissions_potential": -0.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2239, "impact_of_loft_insulation": -224, "space_heating_existing_dwelling": 7228}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.07r02", "energy_consumption_potential": 46, "environmental_impact_current": 93, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 103, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 7, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100011406318, "roofs": [{"description": "Pitched, 350 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 91% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M6 8DA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SALFORD", "built_form": 2, "created_at": "2018-05-25 07:45:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "59, Edward Avenue", "assessment_type": "RdSAP", "completion_date": "2018-05-25", "inspection_date": "2018-02-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.04, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 41.04, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 91, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 495, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 451, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 261, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2128, "space_heating_existing_dwelling": 8543}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 109, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100091459281, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 93% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO10 9HA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUDBURY", "built_form": 2, "created_at": "2018-12-05 13:45:58.000000", "door_count": 3, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Old Court", "address_line_2": "Long Melford", "assessment_type": "RdSAP", "completion_date": "2018-12-05", "inspection_date": "2018-12-05", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 79, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-12-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.87, "quantity": "square metres"}, "party_wall_length": {"value": 4.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 44.25, "quantity": "square metres"}, "party_wall_length": {"value": 4.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 3, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 93, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 505, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 461, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1953, "space_heating_existing_dwelling": 8832}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 103, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 100050961098, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "S20 8JL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 2, "created_at": "2018-04-28 09:34:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Eastcroft Close", "address_line_2": "Westfield", "assessment_type": "RdSAP", "completion_date": "2018-04-28", "inspection_date": "2018-04-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.15, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.15, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 521, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2112, "impact_of_loft_insulation": -242, "impact_of_cavity_insulation": -1965, "space_heating_existing_dwelling": 9464}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100022213354, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 52% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IG2 6TT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-05-31 21:37:01.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17679}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "62, Gantshill Crescent", "assessment_type": "RdSAP", "completion_date": "2018-05-31", "inspection_date": "2018-05-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 131, "transaction_type": 8, "conservatory_type": 4, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 11.63, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 4.14, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 31.46, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.71, "quantity": "square metres"}, "party_wall_length": {"value": 17.79, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 42.34, "quantity": "square metres"}, "party_wall_length": {"value": 14.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 52, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 705, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 597, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2065, "impact_of_loft_insulation": -1204, "impact_of_solid_wall_insulation": -1654, "space_heating_existing_dwelling": 13294}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 23, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100120001600, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BA2 8DH", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BATH", "built_form": 2, "created_at": "2018-05-01 12:23:04.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "No system present: electric heaters assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "19a, Bath Road", "address_line_2": "Peasedown St. John", "assessment_type": "RdSAP", "completion_date": "2018-05-01", "inspection_date": "2018-05-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 61, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "true", "registration_date": "2018-05-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 460, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 60.79, "quantity": "square metres"}, "party_wall_length": {"value": 8.66, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1401, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 19, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 846, "currency": "GBP"}, "hot_water_cost_current": {"value": 424, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 544, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 47}, {"sequence": 4, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 49}], "co2_emissions_potential": 3.9, "energy_rating_potential": 42, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 769, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 680, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 312, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2633, "impact_of_solid_wall_insulation": -3372, "space_heating_existing_dwelling": 8692}, "energy_consumption_current": 593, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 377, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "G", "environmental_impact_potential": 49, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "E", "co2_emissions_current_per_floor_area": 100, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10010749427, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SK22 4AA", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "HIGH PEAK", "built_form": 3, "created_at": "2018-06-19 21:01:12.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "56a, Market Street", "address_line_2": "New Mills", "assessment_type": "RdSAP", "completion_date": "2018-06-19", "inspection_date": "2018-06-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-06-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 420, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "total_floor_area": {"value": 45.24, "quantity": "square metres"}, "party_wall_length": {"value": 8.44, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 1010, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 464, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 26}, {"sequence": 2, "typical_saving": {"value": 340, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 41}, {"sequence": 4, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 48}], "co2_emissions_potential": 3.9, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 281, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1867, "impact_of_loft_insulation": -758, "impact_of_solid_wall_insulation": -3840, "space_heating_existing_dwelling": 11330}, "energy_consumption_current": 916, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 509, "environmental_impact_current": 23, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 48, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 155, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10007904673, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 19% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "RG17 8XN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUNGERFORD", "built_form": 1, "created_at": "2018-06-21 16:00:20.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 511}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, High Street", "address_line_2": "Lambourn", "assessment_type": "RdSAP", "completion_date": "2018-06-21", "inspection_date": "2018-06-21", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 136, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-06-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 52.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 19, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1152, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 144, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 854, "currency": "GBP"}, "hot_water_cost_current": {"value": 174, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 87}, {"sequence": 2, "typical_saving": {"value": 359, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2981, "impact_of_loft_insulation": -857, "space_heating_existing_dwelling": 16339}, "energy_consumption_current": 282, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 144, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10090399339, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL11 2NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WREXHAM", "built_form": 4, "created_at": "2018-03-09 13:44:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16812}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "66, Rhosddu Road", "assessment_type": "RdSAP", "completion_date": "2018-03-09", "inspection_date": "2018-03-09", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-03-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.96, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 345, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 28, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 270, "currency": "GBP"}, "hot_water_cost_current": {"value": 66, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.4, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 28, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1458, "impact_of_loft_insulation": -526, "impact_of_solid_wall_insulation": -1223, "space_heating_existing_dwelling": 4747}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 214, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070476772, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 90% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B26 2DA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2018-08-15 20:28:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "18, Partridge Road", "assessment_type": "RdSAP", "completion_date": "2018-08-15", "inspection_date": "2018-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 4, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 6.45, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 7.59}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 225, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.34, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.99, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 37.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 840, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 468, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 118, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2123, "impact_of_solid_wall_insulation": -3764, "space_heating_existing_dwelling": 12609}, "energy_consumption_current": 341, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 108, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 217070627, "roofs": [{"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W11 4NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-01-10 15:42:22.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2105, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17690}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "98, Princedale Road", "assessment_type": "RdSAP", "completion_date": "2018-01-10", "inspection_date": "2018-01-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "roof_u_value": 0.13, "wall_u_value": 0.28, "wall_dry_lined": "N", "wall_thickness": 410, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 29.33, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 29.33, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 29.33, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}, {"floor": 3, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 29.33, "quantity": "square metres"}, "party_wall_length": {"value": 13.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.78, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "floor_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and at least two room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 445, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2945, "space_heating_existing_dwelling": 7613}, "energy_consumption_current": 137, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 76, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 49, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 49} +{"uprn": 100071063810, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "WS9 8RU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALSALL", "built_form": 1, "created_at": "2018-11-29 21:16:07.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "14, Kingshayes Road", "address_line_2": "Aldridge", "assessment_type": "RdSAP", "completion_date": "2018-11-29", "inspection_date": "2018-11-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.02, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.19, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.29, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 547, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 466, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1886, "impact_of_loft_insulation": -361, "space_heating_existing_dwelling": 8770}, "energy_consumption_current": 294, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 88, "calculation_software_version": "3.08r07", "energy_consumption_potential": 139, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100061154404, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 46% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ME20 6UZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AYLESFORD", "built_form": 3, "created_at": "2018-10-16 21:52:39.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2, Sassoon Close", "address_line_2": "Larkfield", "assessment_type": "RdSAP", "completion_date": "2018-10-16", "inspection_date": "2018-10-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 19.69, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.83, "quantity": "square metres"}, "party_wall_length": {"value": 8.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 29.61, "quantity": "square metres"}, "party_wall_length": {"value": 8.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 475, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 378, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 71}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2129, "impact_of_loft_insulation": -235, "impact_of_cavity_insulation": -1644, "space_heating_existing_dwelling": 8229}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 73, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040342902, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TQ14 8RF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TEIGNMOUTH", "built_form": 1, "created_at": "2018-07-20 17:22:24.000000", "door_count": 4, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16375}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "1, Higher Holcombe Drive", "assessment_type": "RdSAP", "completion_date": "2018-07-20", "inspection_date": "2018-07-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-07-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 80.55, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.19, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.45, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 633, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 472, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2125, "impact_of_loft_insulation": -680, "space_heating_existing_dwelling": 9942}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 96, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 39040781, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WA10 2EX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ST. HELENS", "built_form": 2, "created_at": "2018-06-25 18:30:46.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "23, Napier Street", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 383, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 271, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.5, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1645, "space_heating_existing_dwelling": 4529}, "energy_consumption_current": 265, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 182, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 37027082, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "PO12 2NZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "GOSPORT", "built_form": 4, "created_at": "2018-01-05 16:56:03.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 23 Pilbrow Court", "address_line_2": "Canberra Close", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 45, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 45.12, "quantity": "square metres"}, "party_wall_length": {"value": 20.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 51, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 57, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 79}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 120, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1624, "space_heating_existing_dwelling": 523}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 150, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "B", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100000060765, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"access_issues": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 14% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NE8 2PL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GATESHEAD", "built_form": 2, "created_at": "2018-08-21 15:00:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "57, Upton Street", "assessment_type": "RdSAP", "completion_date": "2018-08-21", "inspection_date": "2018-08-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 51, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.7, "quantity": "square metres"}, "party_wall_length": {"value": 17.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 305, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1956, "impact_of_cavity_insulation": -1218, "space_heating_existing_dwelling": 5428}, "energy_consumption_current": 253, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 180, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 77031138, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "M40 9JD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-10-17 18:33:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "18, Bluestone Road", "assessment_type": "RdSAP", "completion_date": "2018-10-17", "inspection_date": "2018-10-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.62, "quantity": "square metres"}, "party_wall_length": {"value": 15.04, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 36.62, "quantity": "square metres"}, "party_wall_length": {"value": 15.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.53, "quantity": "square metres"}, "party_wall_length": {"value": 3.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 9.53, "quantity": "square metres"}, "party_wall_length": {"value": 3.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 740, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 634, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2334, "impact_of_loft_insulation": -3939, "impact_of_solid_wall_insulation": -2918, "space_heating_existing_dwelling": 14304}, "energy_consumption_current": 275, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 163, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100022216439, "roofs": [{"description": "Pitched, 25 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG1 1PS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-12-15 13:12:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "6a, Hampton Road", "assessment_type": "RdSAP", "completion_date": "2018-12-15", "inspection_date": "2018-12-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 62.01, "quantity": "square metres"}, "party_wall_length": {"value": 29.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 524, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": "Room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 217, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 86, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1890, "impact_of_loft_insulation": -2155, "impact_of_solid_wall_insulation": -2571, "space_heating_existing_dwelling": 7694}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "3.08r08", "energy_consumption_potential": 118, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100011763563, "roofs": [{"description": "Flat, insulated", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WN3 5UU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIGAN", "built_form": 2, "created_at": "2018-05-15 10:19:11.000000", "door_count": 2, "glazed_area": 3, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8100}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "22, Cheetham Grove", "assessment_type": "RdSAP", "completion_date": "2018-05-15", "inspection_date": "2018-04-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.09, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 467, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 344, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 41, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1670, "space_heating_existing_dwelling": 6837}, "energy_consumption_current": 307, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 88, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100060355127, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO16 9HL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FAREHAM", "built_form": 2, "created_at": "2018-05-10 08:39:28.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "33, Seaway Grove", "assessment_type": "RdSAP", "completion_date": "2018-05-10", "inspection_date": "2018-05-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 64.22, "quantity": "square metres"}, "party_wall_length": {"value": 10.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.52, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 315, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 317, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1922, "space_heating_existing_dwelling": 4508}, "energy_consumption_current": 167, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 162, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060825115, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT1 1EW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CANTERBURY", "built_form": 4, "created_at": "2018-05-09 11:25:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "86, Tennyson Avenue", "assessment_type": "RdSAP", "completion_date": "2018-05-09", "inspection_date": "2018-05-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-05-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 294, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.68, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 39.68, "quantity": "square metres"}, "party_wall_length": {"value": 12.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 503, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2274, "impact_of_loft_insulation": -2466, "space_heating_existing_dwelling": 8749}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 107, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021914141, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW2 3TP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-07-01 13:06:29.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "First Floor Flat", "address_line_2": "64 Wyatt Park Road", "assessment_type": "RdSAP", "completion_date": "2018-07-01", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 73.25, "quantity": "square metres"}, "party_wall_length": {"value": 19.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 285, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2041, "impact_of_loft_insulation": -672, "impact_of_solid_wall_insulation": -3615, "space_heating_existing_dwelling": 7876}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "3.05r03", "energy_consumption_potential": 135, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10008544979, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN3 2DU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 4, "created_at": "2018-08-23 21:49:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 5929}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Loxley Walk", "assessment_type": "RdSAP", "completion_date": "2018-08-23", "inspection_date": "2018-08-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.43, "quantity": "square metres"}, "party_wall_length": {"value": 11.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 43.43, "quantity": "square metres"}, "party_wall_length": {"value": 11.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 541, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 426, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 89, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2707, "impact_of_loft_insulation": -278, "space_heating_existing_dwelling": 8409}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 88, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100030859303, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LN4 1DJ", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LINCOLN", "built_form": 2, "created_at": "2018-01-23 05:44:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 502, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Warm air, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "36, Winchester Drive", "address_line_2": "Washingborough", "assessment_type": "RdSAP", "completion_date": "2018-01-23", "inspection_date": "2018-01-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.61, "quantity": "square metres"}, "party_wall_length": {"value": 7.67, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 542, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 478, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 1, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a31,250 - \u00a32,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3033, "space_heating_existing_dwelling": 6087}, "energy_consumption_current": 338, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 147, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100062012633, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO32 1DS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 2, "created_at": "2018-01-26 09:10:37.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15107}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "The Pines", "address_line_2": "Hoe Road", "address_line_3": "Bishops Waltham", "assessment_type": "RdSAP", "completion_date": "2018-01-26", "inspection_date": "2018-01-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 195, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 7, "registration_date": "2018-01-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.79, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 97.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.42, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 97.66, "quantity": "square metres"}, "party_wall_length": {"value": 4.42, "quantity": "metres"}, "heat_loss_perimeter": {"value": 36.47, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1387, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.1, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1120, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "co2_emissions_potential": 5.3, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 111, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3016, "space_heating_existing_dwelling": 21195}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.03r05", "energy_consumption_potential": 153, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 28, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 24} +{"uprn": 83082145, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HD2 1QD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HUDDERSFIELD", "built_form": 2, "created_at": "2018-02-16 14:19:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "224, Bradley Road", "address_line_2": "Bradley", "assessment_type": "RdSAP", "completion_date": "2018-02-16", "inspection_date": "2018-02-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 153, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-02-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 30.14, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.21, "quantity": "square metres"}, "party_wall_length": {"value": 7.41, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 17.2, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1094, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 985, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "co2_emissions_potential": 4.9, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 102, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 116, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2321, "impact_of_loft_insulation": -4538, "impact_of_cavity_insulation": -1186, "space_heating_existing_dwelling": 20547}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 178, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100010322974, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WA1 3AQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WARRINGTON", "built_form": 4, "created_at": "2018-02-17 20:02:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Whalley Street", "assessment_type": "RdSAP", "completion_date": "2018-02-17", "inspection_date": "2018-02-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-02-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.83, "quantity": "square metres"}, "party_wall_length": {"value": 16.15, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 31.54, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.01, "quantity": "square metres"}, "party_wall_length": {"value": 2.89, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 6.01, "quantity": "square metres"}, "party_wall_length": {"value": 2.89, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 667, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 470, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2074, "impact_of_loft_insulation": -1021, "impact_of_solid_wall_insulation": -2496, "space_heating_existing_dwelling": 9129}, "energy_consumption_current": 263, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100011555857, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OL7 9RJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHTON-UNDER-LYNE", "built_form": 4, "created_at": "2018-08-15 14:26:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "39, Tiverton Place", "assessment_type": "RdSAP", "completion_date": "2018-08-15", "inspection_date": "2018-08-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 48.67, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.56, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 216, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 216, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1679, "space_heating_existing_dwelling": 2171}, "energy_consumption_current": 146, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 146, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 42133763, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 45% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CH49 2QR", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WIRRAL", "built_form": 1, "created_at": "2018-05-17 11:32:58.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 260}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "6, Droitwich Avenue", "assessment_type": "RdSAP", "completion_date": "2018-05-17", "inspection_date": "2018-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 35.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 595, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 396, "currency": "GBP"}, "hot_water_cost_current": {"value": 242, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 160, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3372, "impact_of_loft_insulation": -376, "space_heating_existing_dwelling": 7457}, "energy_consumption_current": 357, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 70, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 22003347, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN41 1TD", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "BRIGHTON", "built_form": 3, "created_at": "2018-05-10 17:18:30.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 3 York House", "address_line_2": "90, Crown Road", "address_line_3": "Portslade", "assessment_type": "RdSAP", "completion_date": "2018-05-10", "inspection_date": "2018-05-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3.45}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-05-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.418, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 442, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 265, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 59}], "co2_emissions_potential": 2.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 131, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 142, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1649, "space_heating_existing_dwelling": 4909}, "energy_consumption_current": 444, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 327, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 75, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 202037881, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA3 0HS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROW", "built_form": 2, "created_at": "2018-09-29 00:22:43.000000", "door_count": 1, "glazed_area": 2, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Totternhoe Close", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-09-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 144, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.21, "quantity": "square metres"}, "party_wall_length": {"value": 8.19, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 50.21, "quantity": "square metres"}, "party_wall_length": {"value": 8.19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.58, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 706, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 566, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 100, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2315, "impact_of_solid_wall_insulation": -2294, "space_heating_existing_dwelling": 12413}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 90, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100121072346, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BA15 1JJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRADFORD-ON-AVON", "built_form": 2, "created_at": "2018-06-16 15:17:05.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "27, Avon Close", "assessment_type": "RdSAP", "completion_date": "2018-06-16", "inspection_date": "2018-06-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-06-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.8, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.8, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 100, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.32, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 720, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 448, "currency": "GBP"}, "hot_water_cost_current": {"value": 180, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 122, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2890, "impact_of_solid_wall_insulation": -990, "space_heating_existing_dwelling": 10332}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 88, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100022602574, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IG8 9PA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOODFORD GREEN", "built_form": 4, "created_at": "2018-05-09 18:43:09.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15700}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "45, Oak Hill", "assessment_type": "RdSAP", "completion_date": "2018-05-09", "inspection_date": "2018-05-09", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-05-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.48, "quantity": "square metres"}, "party_wall_length": {"value": 15.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 51.48, "quantity": "square metres"}, "party_wall_length": {"value": 15.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 538, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 345, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 156, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2200, "impact_of_solid_wall_insulation": -3245, "space_heating_existing_dwelling": 8789}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 94, "calculation_software_version": "3.05r04", "energy_consumption_potential": 56, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 49042608, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SA48 8NE", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LAMPETER", "built_form": 1, "created_at": "2018-02-05 21:13:10", "door_count": 2, "glazed_area": 1, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 127, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Vaelog Villa", "address_line_2": "Llanfair Clydogau", "assessment_type": "RdSAP", "completion_date": "2018-02-05", "inspection_date": "2018-02-05", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-02-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.87, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 35.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.27, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 932, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 34, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 188, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 375, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 6, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 9, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}, {"sequence": 10, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 99, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.7, "energy_rating_potential": 99, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3809, "impact_of_loft_insulation": -522, "impact_of_solid_wall_insulation": -7630, "space_heating_existing_dwelling": 17926}, "energy_consumption_current": 345, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": -16, "environmental_impact_current": 33, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "F", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100023433214, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W10 4LG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-07 16:04:57.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17501}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "62, Beethoven Street", "assessment_type": "RdSAP", "completion_date": "2018-09-07", "inspection_date": "2018-09-06", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-09-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.2, "quantity": "square metres"}, "party_wall_length": {"value": 18.47, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.7, "quantity": "square metres"}, "party_wall_length": {"value": 2.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 341, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 234, "currency": "GBP"}, "hot_water_cost_current": {"value": 71, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 14, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1602, "impact_of_solid_wall_insulation": -977, "space_heating_existing_dwelling": 5215}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.07r02", "energy_consumption_potential": 138, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 217037097, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 69% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W10 5FS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-08-01 11:57:02.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8109}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 328 Holmefield House", "address_line_2": "Hazlewood Crescent", "assessment_type": "RdSAP", "completion_date": "2018-08-01", "inspection_date": "2018-07-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 0}, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 65.76, "quantity": "square metres"}, "party_wall_length": {"value": 2.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 36.78, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 69, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 333, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.9, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1944, "space_heating_existing_dwelling": 8340}, "energy_consumption_current": 266, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 168, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 13, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10094526720, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TQ1 4UT", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "TORQUAY", "built_form": 3, "created_at": "2018-01-08 16:22:16.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Managers Apartment Homepalms House", "address_line_2": "Brunswick Square", "assessment_type": "RdSAP", "completion_date": "2018-01-08", "inspection_date": "2018-01-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 55, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.33, "quantity": "square metres"}, "party_wall_length": {"value": 10.48, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 384, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 245, "currency": "GBP"}, "hot_water_cost_current": {"value": 165, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.5, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 160, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 146, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1887, "space_heating_existing_dwelling": 4247}, "energy_consumption_current": 364, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 267, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 235038954, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LN2 5NL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LINCOLN", "built_form": 2, "created_at": "2018-02-14 00:50:58.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16375}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "42, Frederick Street", "assessment_type": "RdSAP", "completion_date": "2018-02-14", "inspection_date": "2018-02-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 13.48, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.65, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 30.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.65, "quantity": "square metres"}, "party_wall_length": {"value": 4.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 782, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 442, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 175, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2085, "impact_of_loft_insulation": -147, "impact_of_solid_wall_insulation": -2581, "space_heating_existing_dwelling": 14981}, "energy_consumption_current": 300, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 95, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100070240580, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV31 2EQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEAMINGTON SPA", "built_form": 2, "created_at": "2018-06-08 10:17:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10565}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "84, Brunswick Street", "assessment_type": "RdSAP", "completion_date": "2018-06-08", "inspection_date": "2018-05-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 139, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-06-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.2, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 45.2, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 768, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 613, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2311, "impact_of_solid_wall_insulation": -3375, "space_heating_existing_dwelling": 14245}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 100, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100110332692, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LA6 2AS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARNFORTH", "built_form": 4, "created_at": "2018-03-15 17:39:58.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2, Horse Market", "address_line_2": "Kirkby Lonsdale", "assessment_type": "RdSAP", "completion_date": "2018-03-15", "inspection_date": "2018-03-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 44, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-03-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 560, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.39, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 13.39, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 560, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.46, "quantity": "square metres"}, "party_wall_length": {"value": 3.6, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.2, "quantity": "metres"}, "total_floor_area": {"value": 8.46, "quantity": "square metres"}, "party_wall_length": {"value": 3.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 520, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 247, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 83}, {"sequence": 7, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 94, "environmental_impact_rating": 96}], "co2_emissions_potential": 0.3, "energy_rating_potential": 94, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 49, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1602, "impact_of_solid_wall_insulation": -2618, "space_heating_existing_dwelling": 7189}, "energy_consumption_current": 383, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.04r01", "energy_consumption_potential": 30, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 96, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10010509203, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV21 2NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RUGBY", "built_form": 2, "created_at": "2018-06-13 17:46:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, The Sidings", "assessment_type": "RdSAP", "completion_date": "2018-06-13", "inspection_date": "2018-03-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 52, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 494, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 494, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2251, "space_heating_existing_dwelling": 7975}, "energy_consumption_current": 162, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 97, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100090637156, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CO12 4LA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARWICH", "built_form": 2, "created_at": "2018-02-11 15:35:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "7, The Haven", "assessment_type": "RdSAP", "completion_date": "2018-02-11", "inspection_date": "2018-02-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.02, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 365, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 330, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.7, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2468, "space_heating_existing_dwelling": 5271}, "energy_consumption_current": 278, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 82, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100021048712, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 86% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E9 5QE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-01 18:11:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 4 Edgar House", "address_line_2": "Homerton Road", "assessment_type": "RdSAP", "completion_date": "2018-06-01", "inspection_date": "2018-06-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 51, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.6, "quantity": "square metres"}, "party_wall_length": {"value": 15.3, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 312, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1625, "impact_of_solid_wall_insulation": -1296, "space_heating_existing_dwelling": 4475}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 155, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100050642699, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "S70 4DW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNSLEY", "built_form": 1, "created_at": "2018-08-03 19:44:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8638}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "54, Mount Vernon Road", "assessment_type": "RdSAP", "completion_date": "2018-08-03", "inspection_date": "2018-08-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 130, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-08-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.92, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 41.67, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 22.89, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.71, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 23.29, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 14.11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1106, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 146, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 902, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 4.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 264, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2976, "impact_of_loft_insulation": -242, "space_heating_existing_dwelling": 18898}, "energy_consumption_current": 289, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 173, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120650974, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WR3 7LG", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WORCESTER", "built_form": 2, "created_at": "2018-09-25 18:52:35.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 7, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230001, "number_of_heaters": 7, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, Droitwich Road", "assessment_type": "RdSAP", "completion_date": "2018-09-25", "inspection_date": "2018-07-17", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 222, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 10, "registration_date": "2018-09-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 36.84, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "300mm"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 76.38, "quantity": "square metres"}, "party_wall_length": {"value": 15.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 76.38, "quantity": "square metres"}, "party_wall_length": {"value": 15.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.55, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 245, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 2967, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 19, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": "Controls for high heat retention storage heaters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1731, "currency": "GBP"}, "hot_water_cost_current": {"value": 329, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 332, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 25}, {"sequence": 2, "typical_saving": {"value": 750, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 3, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 41}, {"sequence": 4, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 42}, {"sequence": 5, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 45}], "co2_emissions_potential": 10, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 118, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 187, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2207, "impact_of_loft_insulation": -3348, "impact_of_solid_wall_insulation": -8460, "space_heating_existing_dwelling": 33671}, "energy_consumption_current": 506, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 273, "environmental_impact_current": 21, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "E", "environmental_impact_potential": 45, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 86, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100110543785, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DL1 2SE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DARLINGTON", "built_form": 1, "created_at": "2018-07-09 20:50:11.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17038}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Exeter Drive", "assessment_type": "RdSAP", "completion_date": "2018-07-09", "inspection_date": "2018-07-05", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-07-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 39.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.82, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.28, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 8, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 4.01, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.44, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 703, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 640, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1924, "space_heating_existing_dwelling": 10544}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 129, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200000756632, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DT2 8TS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DORCHESTER", "built_form": 1, "created_at": "2018-09-30 12:10:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16841}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "12, Heathlands Close", "address_line_2": "Crossways", "assessment_type": "RdSAP", "completion_date": "2018-09-30", "inspection_date": "2018-09-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 7.3}, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.79, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 65.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.46, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 312, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 312, "currency": "GBP"}, "hot_water_cost_current": {"value": 76, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1710, "impact_of_cavity_insulation": -279, "space_heating_existing_dwelling": 4511}, "energy_consumption_current": 151, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 151, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 38194673, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L3 4DX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LIVERPOOL", "built_form": 6, "created_at": "2018-05-01 19:13:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "103, The Anchorage", "assessment_type": "RdSAP", "completion_date": "2018-05-01", "inspection_date": "2018-04-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-05-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 42.01, "quantity": "square metres"}, "party_wall_length": {"value": 15.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 281, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 209, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 128, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 80, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1832, "space_heating_existing_dwelling": 3081}, "energy_consumption_current": 374, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 176, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100022752785, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W10 4QX", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-20 09:22:00.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2303, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 24 Juniper House", "address_line_2": "3, Fourth Avenue", "assessment_type": "RdSAP", "completion_date": "2018-06-20", "inspection_date": "2018-05-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 31, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-06-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 30.5, "quantity": "square metres"}, "party_wall_length": {"value": 20.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 166, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 25, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 124, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 84}], "co2_emissions_potential": 0.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 25, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1683, "space_heating_existing_dwelling": 1398}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 153, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10024632074, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV37 9JU", "hot_water": {"description": {"value": "From main system, flue gas heat recovery", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "STRATFORD-UPON-AVON", "built_form": 2, "created_at": "2018-06-13 17:51:04", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "Y", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "fghrs_index_number": 60039, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "48b, Glebe Road", "assessment_type": "RdSAP", "completion_date": "2018-06-13", "inspection_date": "2018-04-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 20}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.5, "quantity": "square metres"}, "party_wall_length": {"value": 9.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 46.5, "quantity": "square metres"}, "party_wall_length": {"value": 9.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 7, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 352, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 352, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2203, "space_heating_existing_dwelling": 4996}, "energy_consumption_current": 96, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 85, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "B", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 17, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100060690463, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO18 2AP", "hot_water": {"description": {"value": "From main system, plus solar", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-09-04 16:53:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Cleveland Road", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4, 10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 34.7, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 24.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "Y", "habitable_room_count": 5, "heating_cost_current": {"value": 704, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 466, "currency": "GBP"}, "hot_water_cost_current": {"value": 67, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2040, "impact_of_cavity_insulation": -3103, "space_heating_existing_dwelling": 11783}, "energy_consumption_current": 284, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 108, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10002096939, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SK6 3BF", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "STOCKPORT", "built_form": 6, "created_at": "2018-09-03 19:41:27.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "45 Metcalfe Court", "address_line_2": "Metcalfe Drive", "address_line_3": "Romiley", "assessment_type": "RdSAP", "completion_date": "2018-09-03", "inspection_date": "2018-09-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-03", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 62, "quantity": "square metres"}, "party_wall_length": {"value": 13.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 362, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 254, "currency": "GBP"}, "hot_water_cost_current": {"value": 163, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 12, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 125, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1744, "space_heating_existing_dwelling": 3773}, "energy_consumption_current": 304, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 225, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100022690442, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To external air, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW15 4PA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-28 12:06:24.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "85, Sherfield Gardens", "assessment_type": "RdSAP", "completion_date": "2018-06-28", "inspection_date": "2018-06-27", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 75, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 140, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 35.23, "quantity": "square metres"}, "party_wall_length": {"value": 14.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 35.23, "quantity": "square metres"}, "party_wall_length": {"value": 14.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 140, "floor_heat_loss": 1, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.32, "quantity": "square metres"}, "party_wall_length": {"value": 1.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 506, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 360, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.1, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2093, "space_heating_existing_dwelling": 8773}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 163, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 90% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N4 3BW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-01 09:28:36.000000", "door_count": 1, "glazed_area": 3, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15883}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "88b Thorpedale Road", "assessment_type": "RdSAP", "completion_date": "2018-06-01", "inspection_date": "2018-05-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 35, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 34.9, "quantity": "square metres"}, "party_wall_length": {"value": 14.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 252, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 177, "currency": "GBP"}, "hot_water_cost_current": {"value": 70, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 83}], "co2_emissions_potential": 0.9, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1477, "impact_of_loft_insulation": -213, "impact_of_solid_wall_insulation": -1036, "space_heating_existing_dwelling": 3105}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10003234640, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL9 7PD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GERRARDS CROSS", "built_form": 1, "created_at": "2018-03-15 20:22:36.000000", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17317}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "64, Camp Road", "assessment_type": "RdSAP", "completion_date": "2018-03-15", "inspection_date": "2018-03-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 220, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-03-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 96.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 61.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 94.04, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 51.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.66, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1849, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 131, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1083, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 369, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 9, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 71}], "co2_emissions_potential": 5.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 104, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 199, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3125, "impact_of_loft_insulation": -2313, "impact_of_cavity_insulation": -8312, "space_heating_existing_dwelling": 39043}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 131, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 24, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 47058716, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE30 4PA", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "NORTH SHIELDS", "built_form": 6, "created_at": "2018-08-21 15:50:04.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "39 Bede Court", "address_line_2": "Marden Avenue", "assessment_type": "RdSAP", "completion_date": "2018-08-21", "inspection_date": "2018-08-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 62, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 62.35, "quantity": "square metres"}, "party_wall_length": {"value": 21.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 427, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 270, "currency": "GBP"}, "hot_water_cost_current": {"value": 170, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 154, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 138, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 144, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1820, "space_heating_existing_dwelling": 4470}, "energy_consumption_current": 329, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 238, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100081096408, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HP12 3AA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HIGH WYCOMBE", "built_form": 2, "created_at": "2018-05-26 15:31:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17929}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "134, West Wycombe Road", "assessment_type": "RdSAP", "completion_date": "2018-05-26", "inspection_date": "2018-05-25", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.77, "quantity": "square metres"}, "party_wall_length": {"value": 11.27, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.71, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 461, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 340, "currency": "GBP"}, "hot_water_cost_current": {"value": 64, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1415, "impact_of_loft_insulation": -784, "impact_of_cavity_insulation": -866, "impact_of_solid_wall_insulation": -1215, "space_heating_existing_dwelling": 7842}, "energy_consumption_current": 266, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 195, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100061353574, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT19 9HS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EPSOM", "built_form": 2, "created_at": "2018-04-24 17:03:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1758}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Devon Way", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.31, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 37.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.31, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.23, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 696, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 421, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2175, "impact_of_loft_insulation": -721, "impact_of_solid_wall_insulation": -3371, "space_heating_existing_dwelling": 11599}, "energy_consumption_current": 259, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 83, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 28, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 28} +{"uprn": 100080361621, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SL6 3DE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 2, "created_at": "2018-01-22 16:44:46.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "62, Northumbria Road", "assessment_type": "RdSAP", "completion_date": "2018-01-22", "inspection_date": "2018-01-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 9.4}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 22.56, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 360, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 312, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1999, "space_heating_existing_dwelling": 5437}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 148, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100041210904, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Granite or whinstone, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, with external insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR16 6DF", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "REDRUTH", "built_form": 1, "created_at": "2018-07-25 06:03:49.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Hewkins", "address_line_2": "Lanner Green", "address_line_3": "Lanner", "assessment_type": "RdSAP", "completion_date": "2018-07-25", "inspection_date": "2018-07-24", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 137, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-07-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 700, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.36, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 40.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.36, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 700, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.68, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.67, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 14.68, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.67, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 420, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.45, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 13.45, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "150mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1194, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.0, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 847, "currency": "GBP"}, "hot_water_cost_current": {"value": 342, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 422, "currency": "GBP"}, "indicative_cost": "4,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 51}, {"sequence": 4, "typical_saving": {"value": 345, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 57}], "co2_emissions_potential": 4.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 569, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 555, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2306, "impact_of_loft_insulation": -367, "space_heating_existing_dwelling": 12641}, "energy_consumption_current": 347, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 207, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 57, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 48115665, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW19 2RX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-29 13:53:56.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 14", "address_line_2": "6, Chapter Way", "assessment_type": "RdSAP", "completion_date": "2018-09-29", "inspection_date": "2018-09-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 14.5, "quantity": "metres"}}, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-09-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 34.8, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 70.98, "quantity": "square metres"}, "party_wall_length": {"value": 15.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 326, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 206, "currency": "GBP"}, "hot_water_cost_current": {"value": 209, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 163, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 257, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 199, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 163, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2039, "space_heating_existing_dwelling": 2203}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 200, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100011794096, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WN3 6EG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIGAN", "built_form": 1, "created_at": "2018-05-08 14:05:11.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "88, Melrose Drive", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 14, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 42.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.47, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 599, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 550, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2159, "impact_of_loft_insulation": -117, "space_heating_existing_dwelling": 10889}, "energy_consumption_current": 212, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 123, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10002317903, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 92% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO17 8DU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MALTON", "built_form": 1, "created_at": "2018-04-05 11:57:44.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15791}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "The Lime Tree", "address_line_2": "Scagglethorpe", "assessment_type": "RdSAP", "completion_date": "2018-04-05", "inspection_date": "2018-04-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 505, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 330, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 88, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 57}}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2742, "impact_of_loft_insulation": -684, "impact_of_cavity_insulation": -2193, "space_heating_existing_dwelling": 11656}, "energy_consumption_current": 290, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 118, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 77066288, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "M22 9XU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 4, "created_at": "2018-08-08 16:41:18.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "34, Solway Road", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-08-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.13, "quantity": "square metres"}, "party_wall_length": {"value": 6.01, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 42.13, "quantity": "square metres"}, "party_wall_length": {"value": 12.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.02, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 462, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 421, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2145, "space_heating_existing_dwelling": 7938}, "energy_consumption_current": 193, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 96, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 1775006184, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO2 7PH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PORTSMOUTH", "built_form": 4, "created_at": "2018-01-02 15:16:17.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 4, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Binsteed Road", "assessment_type": "RdSAP", "completion_date": "2018-01-02", "inspection_date": "2018-01-02", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-01-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.04, "quantity": "square metres"}, "party_wall_length": {"value": 13.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.67, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.12, "quantity": "metres"}, "total_floor_area": {"value": 19.78, "quantity": "square metres"}, "party_wall_length": {"value": 14.18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.24, "quantity": "square metres"}, "party_wall_length": {"value": 6.21, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 13.31, "quantity": "square metres"}, "party_wall_length": {"value": 5.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 421, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1910, "impact_of_loft_insulation": -236, "impact_of_cavity_insulation": -1226, "space_heating_existing_dwelling": 8085}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10090335147, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX34 8PF", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ILFRACOMBE", "built_form": 4, "created_at": "2018-03-06 19:15:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "37 Green Parks Holidays Ilfracombe", "address_line_2": "Marlborough Road", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-03-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.64, "quantity": "square metres"}, "party_wall_length": {"value": 13.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 577, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 493, "currency": "GBP"}, "hot_water_cost_current": {"value": 168, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a3500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 0.9, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1043, "space_heating_existing_dwelling": 3578}, "energy_consumption_current": 300, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 106, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10093017920, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO15 2ED", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2018-03-14 09:50:48.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 14 Fairchild House", "address_line_2": "21, Southampton Street", "assessment_type": "RdSAP", "completion_date": "2018-03-14", "inspection_date": "2017-12-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 4.68}, "total_floor_area": 16, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-03-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.9684, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.13, "quantity": "metres"}, "total_floor_area": {"value": 16.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 36, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.6, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 18, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 36, "currency": "GBP"}, "hot_water_cost_current": {"value": 132, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 0.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 18, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 818, "space_heating_existing_dwelling": 220}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 218, "environmental_impact_current": 85, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "B", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050854349, "roofs": [{"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "S60 3BX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROTHERHAM", "built_form": 1, "created_at": "2018-01-08 17:46:41.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15752}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "2, Mortain Road", "assessment_type": "RdSAP", "completion_date": "2018-01-08", "inspection_date": "2017-10-27", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 131, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-01-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 38.8, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "D"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 35.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1707, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.7, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 744, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 185, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 426, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 158, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 7, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 9, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 65}}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2304, "impact_of_loft_insulation": -3290, "impact_of_cavity_insulation": -2485, "space_heating_existing_dwelling": 28317}, "energy_consumption_current": 378, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 124, "environmental_impact_current": 37, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200001526105, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WN7 4EH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEIGH", "built_form": 3, "created_at": "2018-11-01 21:12:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "263a, Twist Lane", "assessment_type": "RdSAP", "completion_date": "2018-11-01", "inspection_date": "2018-10-04", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.65, "quantity": "metres"}}, "total_floor_area": 42, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-11-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.4245, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.04, "quantity": "square metres"}, "party_wall_length": {"value": 4.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 22.41, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 5, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.48, "quantity": "square metres"}, "party_wall_length": {"value": 3.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.48, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.53, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.95, "quantity": "square metres"}, "party_wall_length": {"value": 3.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 465, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 360, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.0, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1583, "impact_of_cavity_insulation": -238, "impact_of_solid_wall_insulation": -1253, "space_heating_existing_dwelling": 7483}, "energy_consumption_current": 342, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 266, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10012793844, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "N5 1DS", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-01 14:02:10.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 23", "address_line_2": "71f, Drayton Park", "assessment_type": "RdSAP", "completion_date": "2018-09-01", "inspection_date": "2018-09-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 0}, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 96.97, "quantity": "square metres"}, "party_wall_length": {"value": 33.15, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 177, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 108, "currency": "GBP"}, "hot_water_cost_current": {"value": 253, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 153, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 231, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 88, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 172, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 89}], "hot_water_cost_potential": {"value": 179, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2081, "space_heating_existing_dwelling": 1177}, "energy_consumption_current": 126, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 120, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100121000295, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN11 0HB", "hot_water": {"description": {"value": "Gas multipoint", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CALNE", "built_form": 4, "created_at": "2018-12-07 08:33:31.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 908, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 609, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "1, Station Road", "assessment_type": "RdSAP", "completion_date": "2018-12-07", "inspection_date": "2018-12-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.21, "quantity": "metres"}}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-12-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.296, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46, "quantity": "square metres"}, "party_wall_length": {"value": 8.71, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.99, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 299, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 209, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "S", "improvement_details": {"improvement_number": 40}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1185, "space_heating_existing_dwelling": 3186}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 150, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100100931985, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CH6 5XW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FLINT", "built_form": 1, "created_at": "2018-12-02 17:18:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Bro Deg", "assessment_type": "RdSAP", "completion_date": "2018-12-02", "inspection_date": "2018-07-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-12-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.93, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.04, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 49.99, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.42, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 623, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 567, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2403, "impact_of_loft_insulation": -120, "space_heating_existing_dwelling": 11439}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 111, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100051037814, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S11 8QJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2018-01-22 17:40:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15520}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "151, Neill Road", "assessment_type": "RdSAP", "completion_date": "2018-01-22", "inspection_date": "2018-01-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 15.66, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "H"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 26.38, "quantity": "square metres"}, "party_wall_length": {"value": 12.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 19.37, "quantity": "square metres"}, "party_wall_length": {"value": 9.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.44, "quantity": "square metres"}, "party_wall_length": {"value": 7.78, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.59, "quantity": "metres"}, "total_floor_area": {"value": 14.89, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 695, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 544, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 15}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.1, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2196, "impact_of_loft_insulation": -2587, "impact_of_solid_wall_insulation": -2280, "space_heating_existing_dwelling": 12962}, "energy_consumption_current": 247, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 130, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 43086937, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF83 8GX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAERPHILLY", "built_form": 2, "created_at": "2018-04-23 13:20:24", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "99, Llanfabon Drive", "address_line_2": "Trethomas", "assessment_type": "RdSAP", "completion_date": "2018-04-23", "inspection_date": "2018-04-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 20}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 39.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.05, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.05, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 688, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 557, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.5, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 98}, {"sequence": 2, "typical_saving": {"value": 141, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2097, "impact_of_loft_insulation": -3772, "space_heating_existing_dwelling": 10602}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 179, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100052176002, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "YO8 4YX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SELBY", "built_form": 4, "created_at": "2018-04-20 11:25:05.000000", "door_count": 3, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Bishop Court", "assessment_type": "RdSAP", "completion_date": "2018-04-20", "inspection_date": "2018-04-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.86, "quantity": "square metres"}, "party_wall_length": {"value": 9.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 41.86, "quantity": "square metres"}, "party_wall_length": {"value": 9.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.44, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 529, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2141, "space_heating_existing_dwelling": 7724}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 92, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010095272, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CW5 5TT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NANTWICH", "built_form": 4, "created_at": "2018-10-30 21:02:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Alvaston Road", "assessment_type": "RdSAP", "completion_date": "2018-10-30", "inspection_date": "2018-10-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.7, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 31.7, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 450, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 357, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2050, "impact_of_cavity_insulation": -903, "space_heating_existing_dwelling": 6704}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 83, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100091597288, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SS4 3HH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROCHFORD", "built_form": 1, "created_at": "2018-09-27 16:11:25.000000", "door_count": 2, "glazed_area": 4, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "sap_windows": [{"pvc_frame": "false", "orientation": 1, "window_area": {"value": 5.02, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 1, "window_area": {"value": 3.66, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 3, "window_area": {"value": 0.41, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 7, "window_area": {"value": 1.85, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 4.5, "quantity": "square metres"}, "window_type": 1, "glazing_type": 1, "window_location": 0}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "5, Clifton Road", "assessment_type": "RdSAP", "completion_date": "2018-09-27", "inspection_date": "2018-09-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 600, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 364, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1967, "impact_of_solid_wall_insulation": -3954, "space_heating_existing_dwelling": 11075}, "energy_consumption_current": 293, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 74, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100080967890, "roofs": [{"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 62% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "AL10 8TX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HATFIELD", "built_form": 4, "created_at": "2018-12-14 18:31:54.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "66, Wood Close", "assessment_type": "RdSAP", "completion_date": "2018-12-14", "inspection_date": "2018-12-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 137, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-12-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 150, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.73, "quantity": "square metres"}, "party_wall_length": {"value": 16.02, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 43.73, "quantity": "square metres"}, "party_wall_length": {"value": 16.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.92, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 43.73, "quantity": "square metres"}, "party_wall_length": {"value": 16.02, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.19, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 633, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 113, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 506, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 2.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2837, "space_heating_existing_dwelling": 11877}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 80, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 25077482, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 30% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "MK46 5HT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OLNEY", "built_form": 1, "created_at": "2018-11-23 18:13:14", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16211}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "11, Spring Lane", "assessment_type": "RdSAP", "completion_date": "2018-11-23", "inspection_date": "2018-11-23", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 111, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"floor_area": 11.25, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 8.05}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 75.91, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.9, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 815, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 645, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2164, "impact_of_solid_wall_insulation": -2485, "space_heating_existing_dwelling": 14765}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 123, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100060845898, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT5 2PY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WHITSTABLE", "built_form": 1, "created_at": "2018-10-08 21:50:47.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "47, Kemp Road", "assessment_type": "RdSAP", "completion_date": "2018-10-08", "inspection_date": "2018-10-08", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 64, "transaction_type": 5, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.21, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 616, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2110, "impact_of_cavity_insulation": -1928, "space_heating_existing_dwelling": 8962}, "energy_consumption_current": 281, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200002791782, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "E8 3LQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-15 16:44:06.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "373, Queensbridge Road", "assessment_type": "RdSAP", "completion_date": "2018-06-15", "inspection_date": "2018-06-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 8}, "total_floor_area": 46, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 18.8, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.35, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 284, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 221, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1643, "space_heating_existing_dwelling": 3152}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 148, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10013890806, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU9 8SX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FARNHAM", "built_form": 1, "created_at": "2018-04-08 16:46:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Basement flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6, Farnham Cloisters", "address_line_2": "41, Shortheath Road", "assessment_type": "RdSAP", "completion_date": "2018-04-08", "inspection_date": "2018-04-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 1}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.89, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 207, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 207, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 121, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2323, "space_heating_existing_dwelling": 1957}, "energy_consumption_current": 129, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 129, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021971978, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SE12 9NF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-10-10 11:19:29.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "33, Jevington Way", "assessment_type": "RdSAP", "completion_date": "2018-10-10", "inspection_date": "2018-10-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-10-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 235, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.66, "quantity": "square metres"}, "party_wall_length": {"value": 6.39, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 34.17, "quantity": "square metres"}, "party_wall_length": {"value": 6.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 500, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 312, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.7, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2243, "impact_of_loft_insulation": -166, "impact_of_solid_wall_insulation": -3542, "space_heating_existing_dwelling": 8664}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 59, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 235017719, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [6, 10]}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LN5 8JS", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LINCOLN", "built_form": 3, "created_at": "2018-10-02 15:25:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "54, Shakespeare Street", "assessment_type": "RdSAP", "completion_date": "2018-10-02", "inspection_date": "2018-10-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 21, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-10-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.77, "quantity": "square metres"}, "party_wall_length": {"value": 10.72, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 117, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 24, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Controls for high heat retention storage heaters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 117, "currency": "GBP"}, "hot_water_cost_current": {"value": 191, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 168, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1351, "space_heating_existing_dwelling": 1243}, "energy_consumption_current": 403, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 379, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 4, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090221774, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE1 3BB", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "PETERBOROUGH", "built_form": 2, "created_at": "2018-10-29 12:54:12.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "59, St. Martins Street", "assessment_type": "RdSAP", "completion_date": "2018-10-29", "inspection_date": "2018-10-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 5.11}, "total_floor_area": 34, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-10-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.3662, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 33.56, "quantity": "square metres"}, "party_wall_length": {"value": 2.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 631, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 34, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 201, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 232, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 329, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 269, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 127, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1506, "impact_of_cavity_insulation": -1192, "space_heating_existing_dwelling": 4307}, "energy_consumption_current": 550, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.08r07", "energy_consumption_potential": 369, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 93, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 42125553, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 18% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CH44 3DY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 2, "created_at": "2018-03-27 18:57:06.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "38, Willoughby Road", "assessment_type": "RdSAP", "completion_date": "2018-03-27", "inspection_date": "2018-03-27", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.05, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 52.05, "quantity": "square metres"}, "party_wall_length": {"value": 8.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.29, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.27, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.67, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 18, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 791, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 473, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2396, "impact_of_loft_insulation": -827, "impact_of_solid_wall_insulation": -5633, "space_heating_existing_dwelling": 14233}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 85, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100061614181, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GU7 3AP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GODALMING", "built_form": 1, "created_at": "2018-09-24 08:24:02", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17055}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Chalk Road", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 15.76, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 30.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 37.51, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1304, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 797, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 228, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.5, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1975, "impact_of_loft_insulation": -1962, "impact_of_cavity_insulation": -3973, "space_heating_existing_dwelling": 22018}, "energy_consumption_current": 419, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 189, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10070725465, "roofs": [{"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TW11 8JD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TEDDINGTON", "built_form": 4, "created_at": "2018-08-08 14:06:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "Flat", "address_line_2": "106, High Street", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-08-07", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 253, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": 130.75, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "C", "roof_insulation_thickness": "100mm"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 130.75, "quantity": "square metres"}, "party_wall_length": {"value": 26.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1265, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 188, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 811, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 89, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 392, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 74}], "co2_emissions_potential": 5.1, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 125, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 141, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3046, "impact_of_solid_wall_insulation": -1353, "space_heating_existing_dwelling": 26218}, "energy_consumption_current": 173, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 93, "calculation_software_version": "3.06r03", "energy_consumption_potential": 113, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "TW16 5HT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNBURY-ON-THAMES", "built_form": 4, "created_at": "2018-08-15 18:20:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8574}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "Top Floor Flat", "address_line_2": "7 The Avenue", "assessment_type": "RdSAP", "completion_date": "2018-08-15", "inspection_date": "2018-08-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.16, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.16, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 425, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 340, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.1, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2632, "impact_of_loft_insulation": -381, "impact_of_cavity_insulation": -1335, "space_heating_existing_dwelling": 6271}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 157, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100070685202, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CV6 5FD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 4, "created_at": "2018-11-22 08:48:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "117, Oliver Street", "assessment_type": "RdSAP", "completion_date": "2018-11-22", "inspection_date": "2018-11-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.33, "quantity": "square metres"}, "party_wall_length": {"value": 16.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.81, "quantity": "metres"}, "total_floor_area": {"value": 28.33, "quantity": "square metres"}, "party_wall_length": {"value": 16.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.98, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.35, "quantity": "square metres"}, "party_wall_length": {"value": 5.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 428, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1919, "impact_of_loft_insulation": -374, "impact_of_cavity_insulation": -376, "space_heating_existing_dwelling": 7165}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 118, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100050471448, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "YO11 1NJ", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SCABOROUGH", "built_form": 4, "created_at": "2018-10-10 11:56:59.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "38 Eastborough", "assessment_type": "RdSAP", "completion_date": "2018-10-10", "inspection_date": "2018-10-08", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.09, "quantity": "metres"}}, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-10-10", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.3, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.613, "quantity": "metres"}, "total_floor_area": {"value": 42.0828, "quantity": "square metres"}, "party_wall_length": {"value": 11.568, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.702, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 526, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 319, "currency": "GBP"}, "hot_water_cost_current": {"value": 263, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 43, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.9, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 263, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1591, "impact_of_solid_wall_insulation": -415, "space_heating_existing_dwelling": 3177}, "energy_consumption_current": 371, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 271, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100020651502, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SE19 3DX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-10-27 23:04:00.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "121, Menlo Gardens", "assessment_type": "RdSAP", "completion_date": "2018-10-27", "inspection_date": "2018-10-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.94, "quantity": "square metres"}, "party_wall_length": {"value": 8.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 37.94, "quantity": "square metres"}, "party_wall_length": {"value": 8.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 471, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 338, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 75}}], "hot_water_cost_potential": {"value": 100, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2328, "impact_of_cavity_insulation": -2265, "space_heating_existing_dwelling": 7559}, "energy_consumption_current": 214, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 151, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050381513, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO61 3NR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "YORK", "built_form": 1, "created_at": "2018-09-04 10:51:38.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "24, Stonefield Avenue", "address_line_2": "Easingwold", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 315, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 40.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 315, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.51, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 871, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 83, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 633, "currency": "GBP"}, "hot_water_cost_current": {"value": 170, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 174, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 314, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2653, "space_heating_existing_dwelling": 10868}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 142, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 25108018, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "MK4 4HD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MILTON KEYNES", "built_form": 1, "created_at": "2018-12-21 17:14:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8140}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Clitheroe Croft", "address_line_2": "Kingsmead", "assessment_type": "RdSAP", "completion_date": "2018-12-21", "inspection_date": "2018-12-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 135, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-12-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 37.26, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.09, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 45.98, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 27.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 597, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 138, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 36}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 148, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 113, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2283, "space_heating_existing_dwelling": 8073}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 79, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 45038130, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 15% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SR3 1RL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 2, "created_at": "2018-07-05 13:04:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Princetown Terrace", "assessment_type": "RdSAP", "completion_date": "2018-07-05", "inspection_date": "2018-07-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 115, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-07-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 57.3, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 15, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1012, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 137, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 739, "currency": "GBP"}, "hot_water_cost_current": {"value": 112, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 109, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 130, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2280, "impact_of_loft_insulation": -726, "space_heating_existing_dwelling": 14635}, "energy_consumption_current": 273, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 139, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100050841033, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "S65 1RE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROTHERHAM", "built_form": 4, "created_at": "2018-05-16 14:19:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16814}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Hardwicke Road", "assessment_type": "RdSAP", "completion_date": "2018-05-16", "inspection_date": "2018-05-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.4, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 32.4, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.58, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.62, "quantity": "metres"}, "total_floor_area": {"value": 6.38, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 723, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No time or thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 444, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 8, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.5, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 66}}], "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1914, "impact_of_cavity_insulation": -1855, "impact_of_solid_wall_insulation": -785, "space_heating_existing_dwelling": 12778}, "energy_consumption_current": 298, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 24044766, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 63% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS49 4RA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2018-05-15 14:55:50.000000", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "28, Jones Close", "address_line_2": "Yatton", "assessment_type": "RdSAP", "completion_date": "2018-05-15", "inspection_date": "2018-05-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.36, "quantity": "square metres"}, "party_wall_length": {"value": 3.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 30.36, "quantity": "square metres"}, "party_wall_length": {"value": 3.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.4, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 575, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 511, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2051, "impact_of_loft_insulation": -363, "space_heating_existing_dwelling": 8189}, "energy_consumption_current": 246, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 117, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 207182389, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EN3 4AY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ENFIELD", "built_form": 4, "created_at": "2018-10-29 15:56:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1821}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Suffolk Road", "assessment_type": "RdSAP", "completion_date": "2018-10-29", "inspection_date": "2018-10-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.83, "quantity": "square metres"}, "party_wall_length": {"value": 15.99, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 35.92, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.91, "quantity": "square metres"}, "party_wall_length": {"value": 1.63, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 645, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 447, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2177, "impact_of_loft_insulation": -1268, "impact_of_cavity_insulation": -574, "impact_of_solid_wall_insulation": -1417, "space_heating_existing_dwelling": 9903}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 95, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 22, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100021916664, "roofs": [{"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 4% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BR1 4JG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BROMLEY", "built_form": 2, "created_at": "2018-02-06 15:01:05.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17825}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Coniston Road", "assessment_type": "RdSAP", "completion_date": "2018-02-06", "inspection_date": "2018-02-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 168, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2018-02-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 19.74, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "C"}, "roof_construction": 7, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.89, "quantity": "square metres"}, "party_wall_length": {"value": 7.52, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.63, "quantity": "metres"}, "total_floor_area": {"value": 61.89, "quantity": "square metres"}, "party_wall_length": {"value": 7.52, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.86, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 4, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1143, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.9, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 174, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 676, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 233, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": 215, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3002, "impact_of_solid_wall_insulation": -4567, "space_heating_existing_dwelling": 22192}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 81, "calculation_software_version": "3.03r05", "energy_consumption_potential": 97, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 45, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10007371063, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 42% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "HR6 0RF", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LEOMINSTER", "built_form": 1, "created_at": "2018-02-06 16:49:22.000000", "door_count": 4, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Farthing Dingle", "address_line_2": "Pudleston", "assessment_type": "RdSAP", "completion_date": "2018-02-06", "inspection_date": "2018-02-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 104, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.414, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 24.992, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 46.414, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.15, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 9.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 42, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1629, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12.8, "energy_rating_average": 60, "energy_rating_current": 37, "lighting_cost_current": {"value": 119, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 914, "currency": "GBP"}, "hot_water_cost_current": {"value": 194, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 433, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 26}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 26}, {"sequence": 3, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a32,000 - \u00a33,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 34}, {"sequence": 4, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 37}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 38}, {"sequence": 6, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 43}], "co2_emissions_potential": 6.3, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 224, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 407, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 89}, {"sequence": 3, "typical_saving": {"value": 191, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 109, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2107, "impact_of_loft_insulation": -1322, "impact_of_cavity_insulation": -6115, "space_heating_existing_dwelling": 22738}, "energy_consumption_current": 707, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 351, "environmental_impact_current": 15, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "F", "environmental_impact_potential": 43, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 122, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100030418491, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LE4 4LG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2018-04-03 12:12:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Hollytree Avenue", "address_line_2": "Birstall", "assessment_type": "RdSAP", "completion_date": "2018-04-03", "inspection_date": "2018-04-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.62, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 37.23, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 481, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 453, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2000, "space_heating_existing_dwelling": 8301}, "energy_consumption_current": 214, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 111, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 32117001, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WS10 0EB", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WEDNESBURY", "built_form": 4, "created_at": "2018-06-25 00:04:32.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "176, Crankhall Lane", "assessment_type": "RdSAP", "completion_date": "2018-06-25", "inspection_date": "2018-06-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-06-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.64, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 35.64, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 985, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 489, "currency": "GBP"}, "hot_water_cost_current": {"value": 189, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 431, "currency": "GBP"}, "indicative_cost": "\u00a31,600 - \u00a32,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 65}], "co2_emissions_potential": 2.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 591, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 487, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1748, "space_heating_existing_dwelling": 6916}, "energy_consumption_current": 387, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 232, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 63017435, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF8 2QR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTEFRACT", "built_form": 2, "created_at": "2018-03-30 11:05:13.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "53, Carleton Crest", "assessment_type": "RdSAP", "completion_date": "2018-03-30", "inspection_date": "2018-03-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 85, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.43, "quantity": "square metres"}, "party_wall_length": {"value": 6.98, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 41.25, "quantity": "square metres"}, "party_wall_length": {"value": 6.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.12, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 719, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1961, "impact_of_loft_insulation": -561, "impact_of_cavity_insulation": -2939, "space_heating_existing_dwelling": 13687}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 126, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100050216976, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 13% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "DN15 9UE", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SCUNTHORPE", "built_form": 2, "created_at": "2018-02-02 07:46:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Parkhill Rise", "address_line_2": "Winterton", "assessment_type": "RdSAP", "completion_date": "2018-02-02", "inspection_date": "2018-01-31", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "registration_date": "2018-02-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.57, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 40.88, "quantity": "square metres"}, "party_wall_length": {"value": 7.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.19, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.45, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 642, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 255, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 5, "typical_saving": {"value": 226, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 98, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 271, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3552, "space_heating_existing_dwelling": 7651}, "energy_consumption_current": 293, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10013310697, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Timber frame, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CT9 1NX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MARGATE", "built_form": 3, "created_at": "2018-02-02 16:57:24.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16637}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat C", "address_line_2": "4 Cecil Street", "assessment_type": "RdSAP", "completion_date": "2018-02-02", "inspection_date": "2018-01-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 5.7}, "total_floor_area": 86, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-02-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.97, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 130, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "total_floor_area": {"value": 86.27, "quantity": "square metres"}, "party_wall_length": {"value": 4.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 860, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 101, "currency": "GBP"}, "main_heating_controls": [{"description": "No time or thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 283, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 371, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2010, "impact_of_solid_wall_insulation": -1513, "space_heating_existing_dwelling": 15610}, "energy_consumption_current": 319, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.03r05", "energy_consumption_potential": 111, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010065889, "roofs": [{"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Roof room(s), insulated", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"narrow_cavities": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ST7 3LF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2018-09-12 17:08:44.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "61a, The Bank", "address_line_2": "Scholar Green", "assessment_type": "RdSAP", "completion_date": "2018-09-12", "inspection_date": "2018-09-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 36, "insulation": 3, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.61, "quantity": "square metres"}, "party_wall_length": {"value": 7.47, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.41, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "50mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 800, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 571, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2307, "impact_of_cavity_insulation": -505, "space_heating_existing_dwelling": 12264}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 125, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10090797067, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DA17 6JT", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BELVEDERE", "built_form": 4, "created_at": "2018-09-19 09:15:39.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17814}, {"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 2, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 0, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17814}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Caldy Road", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.92, "quantity": "square metres"}, "party_wall_length": {"value": 13.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 34.91, "quantity": "square metres"}, "party_wall_length": {"value": 13.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 34.84, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.36, "quantity": "square metres"}, "party_wall_length": {"value": 2.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 386, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 379, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.2, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2640, "space_heating_existing_dwelling": 5678}, "energy_consumption_current": 128, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 57, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 25, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 25} +{"uprn": 10012060678, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL5 3UQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 1, "created_at": "2018-07-14 09:15:30.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "15, Echo Crescent", "assessment_type": "RdSAP", "completion_date": "2018-07-14", "inspection_date": "2018-07-13", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 60.97, "quantity": "square metres"}, "party_wall_length": {"value": 6.11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 232, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 232, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1693, "space_heating_existing_dwelling": 2686}, "energy_consumption_current": 122, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 122, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100040049706, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR3 7QA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "TRURO", "built_form": 1, "created_at": "2018-04-07 23:22:40.000000", "door_count": 0, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16497}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Ka-Jora", "address_line_2": "St. Pirans Hill", "address_line_3": "Perranwell Station", "assessment_type": "RdSAP", "completion_date": "2018-04-07", "inspection_date": "2018-04-07", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 82.44, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 39.49, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 640, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 430, "currency": "GBP"}, "hot_water_cost_current": {"value": 229, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 168, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3190, "space_heating_existing_dwelling": 8052}, "energy_consumption_current": 343, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 98, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100010789815, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, limited insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "FY4 4AF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKPOOL", "built_form": 2, "created_at": "2018-11-09 08:55:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Burnside Avenue", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-11-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 29.99, "quantity": "square metres"}, "party_wall_length": {"value": 5.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.46, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 526, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 395, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1964, "impact_of_solid_wall_insulation": -532, "space_heating_existing_dwelling": 8615}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 92, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 207122351, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "EN1 2QR", "hot_water": {"description": {"value": "No system present: electric immersion assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ENFIELD", "built_form": 2, "created_at": "2018-09-20 11:18:06.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 999, "water_heating_fuel": 0, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "No system present: electric heaters assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "5 Rowley Court", "address_line_2": "32, Wellington Road", "assessment_type": "RdSAP", "completion_date": "2018-09-20", "inspection_date": "2018-09-19", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.24, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 0, "registration_date": "2018-09-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.1568, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 35.66, "quantity": "square metres"}, "party_wall_length": {"value": 1.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.72, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 8.02, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 27.04, "quantity": "square metres"}, "party_wall_length": {"value": 3.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1829, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 4, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1504, "currency": "GBP"}, "hot_water_cost_current": {"value": 539, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 191, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 9, "environmental_impact_rating": 23}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 9, "environmental_impact_rating": 23}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 10, "environmental_impact_rating": 24}, {"sequence": 4, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 13, "environmental_impact_rating": 26}], "co2_emissions_potential": 6.6, "energy_rating_potential": 13, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 11, "environmental_impact_rating": 25}}], "hot_water_cost_potential": {"value": 539, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3259, "impact_of_loft_insulation": -5241, "impact_of_cavity_insulation": -1324, "space_heating_existing_dwelling": 11051}, "energy_consumption_current": 729, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 619, "environmental_impact_current": 19, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "G", "environmental_impact_potential": 26, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "G", "co2_emissions_current_per_floor_area": 123, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 5020495, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WC1H 9QW", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-05-30 08:33:59.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2301, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 58 Clare Court", "address_line_2": "Judd Street", "assessment_type": "RdSAP", "completion_date": "2018-05-30", "inspection_date": "2018-05-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 46, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-05-30", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 330, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 45.9, "quantity": "square metres"}, "party_wall_length": {"value": 8.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 276, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, no thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 136, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1835, "impact_of_solid_wall_insulation": -1414, "space_heating_existing_dwelling": 3187}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r04", "energy_consumption_potential": 120, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10000272704, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 6% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "EX10 0TA", "hot_water": {"description": "From main system, plus solar", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SIDMOUTH", "built_form": 1, "created_at": "2018-11-09 09:16:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 111, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Hayne Park", "address_line_2": "Tipton St. John", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-11-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 182, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4, 10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.17, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 79.17, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 37.56, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.15, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.83, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 6, "solar_water_heating": "Y", "habitable_room_count": 7, "heating_cost_current": {"value": 922, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 193, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 776, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": 80, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 193, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 331, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 99, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 313, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2994, "impact_of_loft_insulation": -102, "space_heating_existing_dwelling": 13549}, "energy_consumption_current": 172, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 99, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100060544188, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GU14 0AX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FARNBOROUGH", "built_form": 3, "created_at": "2018-11-08 16:59:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8793}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "43, Hunter Road", "assessment_type": "RdSAP", "completion_date": "2018-11-08", "inspection_date": "2018-11-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 32.5, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.2, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 649, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 534, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2716, "space_heating_existing_dwelling": 10802}, "energy_consumption_current": 261, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 124, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100060064327, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 92% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN7 3DA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEWES", "built_form": 2, "created_at": "2018-02-20 10:36:55.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15924}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "17, Wells Close", "address_line_2": "Plumpton Green", "assessment_type": "RdSAP", "completion_date": "2018-02-20", "inspection_date": "2018-02-20", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-02-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.89, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 44.89, "quantity": "square metres"}, "party_wall_length": {"value": 7.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.41, "quantity": "square metres"}, "party_wall_length": {"value": 2.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.21, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 92, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 574, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 506, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 67}], "co2_emissions_potential": 3.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2798, "impact_of_loft_insulation": -451, "space_heating_existing_dwelling": 10856}, "energy_consumption_current": 189, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 104, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 25006463, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 85% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK8 8BZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MILTON KEYNES", "built_form": 1, "created_at": "2018-02-21 19:46:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Cambron", "address_line_2": "Two Mile Ash", "assessment_type": "RdSAP", "completion_date": "2018-02-21", "inspection_date": "2018-02-20", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 150, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2018-02-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 9.07, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 8.75}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 51.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 11.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.94, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1047, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 988, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "co2_emissions_potential": 4.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 103, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2846, "impact_of_loft_insulation": -67, "space_heating_existing_dwelling": 15456}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 171, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 100110122334, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 25% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "TS8 9NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MIDDLESBROUGH", "built_form": 4, "created_at": "2018-06-06 08:38:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "61, Lynmouth Close", "address_line_2": "Hemlington", "assessment_type": "RdSAP", "completion_date": "2018-06-06", "inspection_date": "2018-06-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.4, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 27.4, "quantity": "square metres"}, "party_wall_length": {"value": 12.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 302, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 286, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 4, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 92, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.5, "energy_rating_potential": 92, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1777, "impact_of_loft_insulation": -336, "space_heating_existing_dwelling": 4223}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 51, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200000716588, "roofs": [{"description": {"value": "Flat, insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SP10 2JF", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ANDOVER", "built_form": 4, "created_at": "2018-06-05 21:08:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "No system present: electric heaters assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "3, The Broadway", "assessment_type": "RdSAP", "completion_date": "2018-06-05", "inspection_date": "2018-06-05", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.2, "quantity": "metres"}}, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "true", "registration_date": "2018-06-05", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 47.45, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 3, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 2.7, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 20.1, "quantity": "square metres"}, "party_wall_length": {"value": 9.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1551, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.5, "energy_rating_average": 60, "energy_rating_current": 19, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1497, "currency": "GBP"}, "hot_water_cost_current": {"value": 411, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 23, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 161, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 27, "environmental_impact_rating": 39}], "co2_emissions_potential": 5.3, "energy_rating_potential": 27, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 25, "environmental_impact_rating": 35}, {"sequence": 2, "typical_saving": {"value": 1169, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 1037, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 149, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2551, "impact_of_loft_insulation": -1869, "impact_of_cavity_insulation": -983, "space_heating_existing_dwelling": 9620}, "energy_consumption_current": 571, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 466, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "G", "environmental_impact_potential": 39, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "F", "co2_emissions_current_per_floor_area": 97, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10034793780, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some secondary glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 82% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR23 1HP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLS-NEXT-THE-SEA", "built_form": 1, "created_at": "2018-09-29 18:28:11.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17570}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Ostrich House", "address_line_2": "Burnt Street", "assessment_type": "RdSAP", "completion_date": "2018-09-29", "inspection_date": "2018-09-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 321, "transaction_type": 8, "conservatory_type": 3, "heated_room_count": 9, "registration_date": "2018-09-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 58.43, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "ND"}, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 24, "wall_dry_lined": "N", "wall_thickness": 420, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 102.89, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.79, "quantity": "metres"}, "total_floor_area": {"value": 102.89, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 34.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 28.2, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 82, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2859, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 16, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 153, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Time and temperature zone control", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 4, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 2071, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 17, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 570, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 98, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 60}], "co2_emissions_potential": 11, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 156, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 135, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2969, "impact_of_loft_insulation": -304, "impact_of_solid_wall_insulation": -10682, "space_heating_existing_dwelling": 51354}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 17, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 180, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 63051801, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF10 3JF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CASTLEFORD", "built_form": 2, "created_at": "2018-02-28 10:31:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "64a, Henson Grove", "assessment_type": "RdSAP", "completion_date": "2018-02-28", "inspection_date": "2018-02-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 47, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 455, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 35, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 377, "currency": "GBP"}, "hot_water_cost_current": {"value": 73, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 35, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 48, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1623, "impact_of_loft_insulation": -521, "space_heating_existing_dwelling": 6097}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 94, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100051053285, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S2 5GD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2018-02-26 16:21:23.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "12, Plover Court", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.77, "quantity": "square metres"}, "party_wall_length": {"value": 10.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.72, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 384, "currency": "GBP"}, "insulated_door_count": 1, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 349, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "insulated_door_u_value": 1.2, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1863, "impact_of_loft_insulation": -348, "space_heating_existing_dwelling": 6054}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 97, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 24040361, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BS21 5EX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CLEVEDON", "built_form": 2, "created_at": "2018-04-23 15:45:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9632}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "10, Stickland", "assessment_type": "RdSAP", "completion_date": "2018-04-23", "inspection_date": "2018-04-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.5, "quantity": "square metres"}, "party_wall_length": {"value": 1.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 423, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 360, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 310, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "impact_of_loft_insulation": -283, "space_heating_existing_dwelling": 6118}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 64, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 207138701, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EN3 5HT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ENFIELD", "built_form": 4, "created_at": "2018-06-15 11:26:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "9, Croft Road", "assessment_type": "RdSAP", "completion_date": "2018-06-15", "inspection_date": "2018-06-15", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 26.8, "quantity": "square metres"}, "party_wall_length": {"value": 9.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 1, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.3, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 585, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2086, "impact_of_loft_insulation": -2384, "impact_of_solid_wall_insulation": -1803, "space_heating_existing_dwelling": 10555}, "energy_consumption_current": 260, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 120, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100062054121, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CT6 5RL", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "HERNE BAY", "built_form": 6, "created_at": "2018-06-12 16:41:35.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "5, Oakland Court", "address_line_2": "Kings Road", "assessment_type": "RdSAP", "completion_date": "2018-06-12", "inspection_date": "2018-06-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 40, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.07, "quantity": "square metres"}, "party_wall_length": {"value": 19.55, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 148, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 117, "currency": "GBP"}, "hot_water_cost_current": {"value": 236, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 157, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 125, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 124, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1715, "space_heating_existing_dwelling": 1577}, "energy_consumption_current": 270, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 250, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100090225476, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 46% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PE4 7ZD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PETERBOROUGH", "built_form": 1, "created_at": "2018-06-11 20:33:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10323}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "26, Thornemead", "assessment_type": "RdSAP", "completion_date": "2018-06-11", "inspection_date": "2018-06-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 25.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 47.46, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 608, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 561, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2917, "impact_of_loft_insulation": -343, "space_heating_existing_dwelling": 10629}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 120, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100010858128, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BL2 5NH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 4, "created_at": "2018-11-22 07:28:52.000000", "door_count": 4, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "45, Burnmoor Road", "assessment_type": "RdSAP", "completion_date": "2018-11-22", "inspection_date": "2018-11-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.85, "quantity": "square metres"}, "party_wall_length": {"value": 11.15, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 14.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 11.27, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 503, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 398, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a360", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a32,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 6, "typical_saving": {"value": 265, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.3, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1855, "impact_of_loft_insulation": -387, "impact_of_cavity_insulation": -1346, "space_heating_existing_dwelling": 8935}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10007365038, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WR6 5RN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WORCESTER", "built_form": 1, "created_at": "2018-10-04 13:51:48", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1739}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1 Blacksmiths Cottages", "address_line_2": "Meadow Green", "address_line_3": "Whitbourne", "assessment_type": "RdSAP", "completion_date": "2018-10-04", "inspection_date": "2018-10-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 96, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 357, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 325, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 100, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.5, "energy_rating_potential": 100, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3429, "space_heating_existing_dwelling": 6712}, "energy_consumption_current": 163, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": -28, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100100161436, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SA15 2NT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LLANELLI", "built_form": 4, "created_at": "2018-02-22 00:08:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17741}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "9, Burry Street", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 530, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.53, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 27.53, "quantity": "square metres"}, "party_wall_length": {"value": 12.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.23, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.07, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.93, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 587, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 51, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1755, "impact_of_solid_wall_insulation": -2048, "space_heating_existing_dwelling": 8406}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 84, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100090360575, "roofs": [{"description": "Roof room(s), insulated", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SS7 1TA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BENFLEET", "built_form": 1, "created_at": "2018-02-11 10:29:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Kiln Road", "assessment_type": "RdSAP", "completion_date": "2018-02-11", "inspection_date": "2018-02-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 142, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 42.77, "insulation": "NI", "roof_room_connected": "Y", "construction_age_band": "B", "roof_insulation_thickness": "100mm"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.21, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 28.98, "insulation": "NI", "roof_room_connected": "Y", "construction_age_band": "B", "roof_insulation_thickness": "200mm"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1139, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 163, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 900, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 151, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 66}], "co2_emissions_potential": 4.2, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2313, "impact_of_solid_wall_insulation": -3360, "space_heating_existing_dwelling": 22859}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 165, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100090357478, "roofs": [{"description": "Pitched, no insulation", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SS7 3UU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BENFLEET", "built_form": 4, "created_at": "2018-04-26 21:15:28.000000", "door_count": 0, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 15017}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "26, Firfield Road", "assessment_type": "RdSAP", "completion_date": "2018-04-26", "inspection_date": "2018-04-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.05, "quantity": "square metres"}, "party_wall_length": {"value": 15.69, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 45.16, "quantity": "square metres"}, "party_wall_length": {"value": 13.69, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.3, "quantity": "square metres"}, "party_wall_length": {"value": 1.93, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 596, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 128, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 357, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 174, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": 65, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 76}}], "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2901, "impact_of_loft_insulation": -3916, "impact_of_cavity_insulation": -1702, "space_heating_existing_dwelling": 11093}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 61, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 45129606, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SR2 0NZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUNDERLAND", "built_form": 1, "created_at": "2018-11-25 12:49:46.000000", "door_count": 1, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "70, Beechbrooke", "address_line_2": "Ryhope", "assessment_type": "RdSAP", "completion_date": "2018-11-25", "inspection_date": "2018-11-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 9.78}, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-11-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 22.5918, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 340, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 60.45, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 212, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 216, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1728, "space_heating_existing_dwelling": 2223}, "energy_consumption_current": 122, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 115, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010778874, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BB3 2HJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DARWEN", "built_form": 3, "created_at": "2018-01-16 18:46:35.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8597}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "30, Spring Vale Garden Village", "assessment_type": "RdSAP", "completion_date": "2018-01-16", "inspection_date": "2018-01-06", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 21.12, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.63, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.63, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 6.96, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.75, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1667, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.5, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 826, "currency": "GBP"}, "hot_water_cost_current": {"value": 120, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 357, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 350, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2283, "impact_of_loft_insulation": -2593, "impact_of_cavity_insulation": -1601, "space_heating_existing_dwelling": 24113}, "energy_consumption_current": 416, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 179, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100120001994, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 76% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BA2 7BA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BATH", "built_form": 1, "created_at": "2018-11-26 07:39:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10356}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19b, Beech Avenue", "assessment_type": "RdSAP", "completion_date": "2018-11-26", "inspection_date": "2018-11-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-11-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 319, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 30.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 64.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.18, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.74, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.44, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 76, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 835, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 769, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3147, "space_heating_existing_dwelling": 12233}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 118, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 19} +{"uprn": 100061166563, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN10 3RL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "TONBRIDGE", "built_form": 2, "created_at": "2018-10-02 18:56:05.000000", "door_count": 3, "glazed_area": 2, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "22, Ashden Walk", "assessment_type": "RdSAP", "completion_date": "2018-10-02", "inspection_date": "2018-10-02", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 114, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-10-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.63, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 43.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.63, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.62, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.87, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 10.92, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.73, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 688, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 607, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2953, "impact_of_loft_insulation": -658, "space_heating_existing_dwelling": 11621}, "energy_consumption_current": 212, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "3.07r02", "energy_consumption_potential": 121, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 83118280, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF15 7JJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERSEDGE", "built_form": 3, "created_at": "2018-04-29 09:08:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8360}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "9, Melbourne Street", "assessment_type": "RdSAP", "completion_date": "2018-04-29", "inspection_date": "2018-04-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 56, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-04-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 24.33, "wall_dry_lined": "N", "wall_thickness": 330, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.73, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.93, "quantity": "square metres"}, "party_wall_length": {"value": 11.59, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.92, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.73, "quantity": "metres"}, "total_floor_area": {"value": 26.93, "quantity": "square metres"}, "party_wall_length": {"value": 10.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 440, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 5.84, "wall_dry_lined": "N", "wall_thickness": 330, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.46, "quantity": "square metres"}, "party_wall_length": {"value": 1.21, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 685, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 447, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 7, "typical_saving": {"value": 271, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1802, "impact_of_loft_insulation": -803, "impact_of_cavity_insulation": -1039, "impact_of_solid_wall_insulation": -1242, "space_heating_existing_dwelling": 8764}, "energy_consumption_current": 354, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 121, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010795376, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "FY2 9LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BLACKPOOL", "built_form": 2, "created_at": "2018-06-28 15:23:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Countess Crescent", "assessment_type": "RdSAP", "completion_date": "2018-06-28", "inspection_date": "2018-06-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 121, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.75, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 55.75, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 841, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 780, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2293, "space_heating_existing_dwelling": 14468}, "energy_consumption_current": 230, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 156, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100081252152, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SG17 5DG", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SHEFFORD", "built_form": 4, "created_at": "2018-03-27 14:15:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "44a, High Street", "assessment_type": "RdSAP", "completion_date": "2018-03-27", "inspection_date": "2018-03-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 2.6, "quantity": "metres"}}, "total_floor_area": 63, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-03-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 3, "sap_room_in_roof": {"floor_area": {"value": 22.08, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.85, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 41.38, "quantity": "square metres"}, "party_wall_length": {"value": 13.2, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 10.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 988, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.6, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 495, "currency": "GBP"}, "hot_water_cost_current": {"value": 277, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 445, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 52}, {"sequence": 6, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 53}], "co2_emissions_potential": 3.6, "energy_rating_potential": 65, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 208, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1978, "impact_of_solid_wall_insulation": -439, "space_heating_existing_dwelling": 10377}, "energy_consumption_current": 618, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 336, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 53, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 104, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100030510998, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LE10 0EB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HINCKLEY", "built_form": 2, "created_at": "2018-01-13 12:58:18", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Teign Bank Close", "assessment_type": "RdSAP", "completion_date": "2018-01-13", "inspection_date": "2018-01-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.65, "quantity": "square metres"}, "party_wall_length": {"value": 3.68, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 19.65, "quantity": "square metres"}, "party_wall_length": {"value": 3.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.49, "quantity": "square metres"}, "party_wall_length": {"value": 2.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 15.49, "quantity": "square metres"}, "party_wall_length": {"value": 2.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 641, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 385, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 198, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 6, "typical_saving": {"value": 248, "currency": "GBP"}, "indicative_cost": "\u00a39,000 - \u00a314,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2053, "impact_of_solid_wall_insulation": -4298, "space_heating_existing_dwelling": 10834}, "energy_consumption_current": 289, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 76, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100070965415, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 17% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B36 9SG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BIRMINGHAM", "built_form": 1, "created_at": "2018-01-12 18:35:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 113}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "53, Park Hall Crescent", "assessment_type": "RdSAP", "completion_date": "2018-01-12", "inspection_date": "2018-01-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.38, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 31.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 58.38, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.46, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 902, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 133, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 606, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 280, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 122, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 264, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2741, "space_heating_existing_dwelling": 13099}, "energy_consumption_current": 279, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 118, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100012435720, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BL9 7HJ", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURY", "built_form": 6, "created_at": "2018-12-01 10:32:29.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2301, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 Holly Court", "address_line_2": "2, Pimhole Road", "assessment_type": "RdSAP", "completion_date": "2018-12-01", "inspection_date": "2018-11-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 31, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-12-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.6, "quantity": "square metres"}, "party_wall_length": {"value": 16.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 175, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 26, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, no thermostatic control of room temperature", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 175, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 26, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1683, "space_heating_existing_dwelling": 1509}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 208, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100020635876, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CR8 5NG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KENLEY", "built_form": 2, "created_at": "2018-10-15 13:55:16.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "42, Little Roke Avenue", "assessment_type": "RdSAP", "completion_date": "2018-10-15", "inspection_date": "2018-10-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 90, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.05, "quantity": "square metres"}, "party_wall_length": {"value": 11.22, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 41.05, "quantity": "square metres"}, "party_wall_length": {"value": 11.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.58, "quantity": "square metres"}, "party_wall_length": {"value": 3.28, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 612, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 396, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 182, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2129, "impact_of_solid_wall_insulation": -4155, "space_heating_existing_dwelling": 11356}, "energy_consumption_current": 231, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 73, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 32115132, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 73% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B71 1EE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WEST BROMWICH", "built_form": 2, "created_at": "2018-10-14 11:22:05.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, Nelson Street", "assessment_type": "RdSAP", "completion_date": "2018-10-14", "inspection_date": "2018-10-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 3, "registration_date": "2018-10-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 28.8, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 73, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 418, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 387, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1924, "space_heating_existing_dwelling": 6473}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 99, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 38043032, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "L19 3RD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2018-12-10 19:41:52.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17796}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Desford Road", "assessment_type": "RdSAP", "completion_date": "2018-12-10", "inspection_date": "2018-12-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-12-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 43.3, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 835, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 118, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 395, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 18, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 251, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 8, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2180, "impact_of_solid_wall_insulation": -4795, "space_heating_existing_dwelling": 13646}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "2.0.x", "energy_consumption_potential": 78, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 90089755, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 46% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DY5 4RP", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BRIERLEY HILL", "built_form": 1, "created_at": "2018-07-11 17:20:15.000000", "door_count": 3, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 645}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "55, High Street", "address_line_2": "Pensnett", "assessment_type": "RdSAP", "completion_date": "2018-07-11", "inspection_date": "2018-07-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-07-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4, "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 5, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.23, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 43.23, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 22.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.04, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 1, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 46, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1829, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11.0, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 969, "currency": "GBP"}, "hot_water_cost_current": {"value": 319, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 411, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 115, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 36}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 37}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 38}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 39}, {"sequence": 6, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 42}, {"sequence": 7, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 45}, {"sequence": 8, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 56}, {"sequence": 9, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 58}, {"sequence": 10, "typical_saving": {"value": 282, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.9, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 87}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 532, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 59}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4516, "impact_of_loft_insulation": -3100, "impact_of_cavity_insulation": -437, "impact_of_solid_wall_insulation": -6275, "space_heating_existing_dwelling": 22888}, "energy_consumption_current": 541, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 197, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "F", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 95, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100110656679, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE63 9DU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHINGTON", "built_form": 4, "created_at": "2018-05-03 17:22:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15706}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "67, Portia Street", "assessment_type": "RdSAP", "completion_date": "2018-05-03", "inspection_date": "2018-05-02", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.87, "quantity": "square metres"}, "party_wall_length": {"value": 8.18, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 46.87, "quantity": "square metres"}, "party_wall_length": {"value": 8.18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 677, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 560, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2105, "impact_of_loft_insulation": -445, "space_heating_existing_dwelling": 10007}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 128, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100060399126, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "GU52 6AZ", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "FLEET", "built_form": 2, "created_at": "2018-03-14 10:42:59.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8571}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "42, Beaufort Road", "address_line_2": "Church Crookham", "assessment_type": "RdSAP", "completion_date": "2018-03-14", "inspection_date": "2018-03-13", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-03-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.68, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 42.68, "quantity": "square metres"}, "party_wall_length": {"value": 7.57, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.85, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.19, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.73, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.87, "quantity": "square metres"}, "party_wall_length": {"value": 1.22, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 562, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 485, "currency": "GBP"}, "hot_water_cost_current": {"value": 241, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 103, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4127, "impact_of_loft_insulation": -473, "space_heating_existing_dwelling": 8269}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 87, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100100686212, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NP20 5EQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWPORT", "built_form": 4, "created_at": "2018-03-16 11:19:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8407}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Sedgemoor Court", "assessment_type": "RdSAP", "completion_date": "2018-03-16", "inspection_date": "2018-03-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 43.7, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 530, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 486, "currency": "GBP"}, "hot_water_cost_current": {"value": 142, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 10, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 65}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2638, "impact_of_loft_insulation": -2474, "space_heating_existing_dwelling": 8233}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100021403529, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM14 1HS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UPMINSTER", "built_form": 1, "created_at": "2018-03-13 21:51:24.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17700}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Acacia Gardens", "assessment_type": "RdSAP", "completion_date": "2018-03-13", "inspection_date": "2018-03-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 186, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-03-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 98.32, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 42.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 87.56, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 37.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 748, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 195, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 766, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3150", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2996, "impact_of_loft_insulation": -611, "space_heating_existing_dwelling": 14180}, "energy_consumption_current": 150, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 103, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 30, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 400 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N22 5AG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 6, "created_at": "2018-10-29 22:44:44.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17991}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat A", "address_line_2": "57 Arcadian Gardens", "assessment_type": "RdSAP", "completion_date": "2018-10-29", "inspection_date": "2018-10-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 31, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-10-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.805, "quantity": "metres"}, "total_floor_area": {"value": 30.946, "quantity": "square metres"}, "party_wall_length": {"value": 10.869, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.193, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 195, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 166, "currency": "GBP"}, "hot_water_cost_current": {"value": 70, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 84}], "co2_emissions_potential": 0.8, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1569, "impact_of_solid_wall_insulation": -663, "space_heating_existing_dwelling": 1792}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 151, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100020205867, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 59% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DA7 5EN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEXLEYHEATH", "built_form": 2, "created_at": "2018-05-12 12:25:21.000000", "door_count": 2, "glazed_area": 2, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17998}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "77, Dunwich Road", "assessment_type": "RdSAP", "completion_date": "2018-05-12", "inspection_date": "2018-05-11", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 7, "registration_date": "2018-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": 11.44, "room_height": 1.5, "double_glazed": "Y", "glazed_perimeter": 11.4}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.46, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 37.1, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 8, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 14.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 59, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 884, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 731, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 3.0, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2197, "impact_of_loft_insulation": -2905, "impact_of_solid_wall_insulation": -2067, "space_heating_existing_dwelling": 17384}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 146, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 10003515183, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "FY6 7DT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POULTON-LE-FYLDE", "built_form": 2, "created_at": "2018-07-02 10:27:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10126}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "24, Bleasdale Avenue", "assessment_type": "RdSAP", "completion_date": "2018-07-02", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 32.55, "quantity": "square metres"}, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "D", "roof_insulation_thickness": "200mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.44, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 617, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 530, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a380", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2179, "space_heating_existing_dwelling": 9240}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 122, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 28, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 200004628095, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 54% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CM2 7BL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHELMSFORD", "built_form": 4, "created_at": "2018-09-08 23:31:03", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Ebenezer Terrace", "address_line_2": "Tabors Hill", "assessment_type": "RdSAP", "completion_date": "2018-09-08", "inspection_date": "2018-08-29", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.08, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.93, "quantity": "square metres"}, "party_wall_length": {"value": 12.46, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 21.93, "quantity": "square metres"}, "party_wall_length": {"value": 12.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.04, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.62, "quantity": "square metres"}, "party_wall_length": 5.78, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 503, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 400, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1851, "impact_of_loft_insulation": -222, "impact_of_cavity_insulation": -348, "impact_of_solid_wall_insulation": -749, "space_heating_existing_dwelling": 8207}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 97, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100023364271, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW4 7BX", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-08-24 19:26:23.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2605, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 23", "address_line_2": "88 Clapham Park Road", "assessment_type": "RdSAP", "completion_date": "2018-08-24", "inspection_date": "2018-08-22", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 25, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-08-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 295, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 22, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 128, "currency": "GBP"}, "hot_water_cost_current": {"value": 226, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 204, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 65}], "co2_emissions_potential": 1.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 25, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 262, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 226, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1368, "space_heating_existing_dwelling": 1783}, "energy_consumption_current": 412, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 384, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 3, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 70, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 72536491, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LS15 8HZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 4, "created_at": "2018-01-21 20:41:12.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "16 Manston Lane", "assessment_type": "RdSAP", "completion_date": "2018-01-21", "inspection_date": "2018-01-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-01-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53, "quantity": "square metres"}, "party_wall_length": {"value": 22, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 357, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 249, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1810, "impact_of_solid_wall_insulation": -876, "space_heating_existing_dwelling": 4849}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 33, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100091069812, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "IP1 6AP", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "IPSWICH", "built_form": 2, "created_at": "2018-01-26 09:11:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "59, Rosecroft Road", "assessment_type": "RdSAP", "completion_date": "2018-01-26", "inspection_date": "2018-01-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-01-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 6.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 33.6, "quantity": "square metres"}, "party_wall_length": {"value": 6.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.3, "quantity": "square metres"}, "party_wall_length": {"value": 0.84, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1070, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.6, "energy_rating_average": 60, "energy_rating_current": 38, "lighting_cost_current": {"value": 112, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 560, "currency": "GBP"}, "hot_water_cost_current": {"value": 289, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 35}, {"sequence": 2, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 38}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 38}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 39}, {"sequence": 5, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 46}, {"sequence": 6, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 50}, {"sequence": 7, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 139, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 457, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 344, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2053, "impact_of_loft_insulation": -752, "impact_of_cavity_insulation": -3073, "space_heating_existing_dwelling": 12002}, "energy_consumption_current": 636, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 266, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 107, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200003459117, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SE5 7TW", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-01-23 14:06:46.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "No system present: electric heaters assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 18 St. Georges Church", "address_line_2": "55, Wells Way", "assessment_type": "RdSAP", "completion_date": "2018-01-23", "inspection_date": "2018-01-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.67}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "false", "registration_date": "2018-01-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 8, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.142, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 45.16, "quantity": "square metres"}, "party_wall_length": {"value": 4.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 707, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "None", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 301, "currency": "GBP"}, "hot_water_cost_current": {"value": 128, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 49}, {"sequence": 2, "typical_saving": {"value": 419, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 51}], "co2_emissions_potential": 2.9, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 513, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 450, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1755, "space_heating_existing_dwelling": 3687}, "energy_consumption_current": 396, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r04", "energy_consumption_potential": 376, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 51, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100091274197, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [10]}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CO11 2RJ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MANNINGTREE", "built_form": 1, "created_at": "2018-01-23 17:33:24.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Rosemary Cottage", "address_line_2": "Cansey Lane", "address_line_3": "Wix", "assessment_type": "RdSAP", "completion_date": "2018-01-23", "inspection_date": "2018-01-23", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-01-23", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.19, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.13, "quantity": "metres"}, "total_floor_area": {"value": 32.3, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 21.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 6.81, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "E"}, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.56, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1796, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 12.0, "energy_rating_average": 60, "energy_rating_current": 20, "lighting_cost_current": {"value": 126, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 955, "currency": "GBP"}, "hot_water_cost_current": {"value": 358, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 21, "environmental_impact_rating": 10}, {"sequence": 2, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 27, "environmental_impact_rating": 16}, {"sequence": 3, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 18}, {"sequence": 4, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 21}, {"sequence": 5, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 21}, {"sequence": 6, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 22}, {"sequence": 7, "typical_saving": {"value": 506, "currency": "GBP"}, "indicative_cost": "\u00a32,000 - \u00a33,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 31}, {"sequence": 8, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 34}, {"sequence": 9, "typical_saving": {"value": 328, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 39}], "co2_emissions_potential": 5.7, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 31, "environmental_impact_rating": 20}, {"sequence": 2, "typical_saving": {"value": 749, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 94}, {"sequence": 3, "typical_saving": {"value": 551, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 61}], "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2527, "impact_of_loft_insulation": -3930, "impact_of_cavity_insulation": -3004, "impact_of_solid_wall_insulation": -769, "space_heating_existing_dwelling": 20216}, "energy_consumption_current": 877, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 410, "environmental_impact_current": 9, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "G", "environmental_impact_potential": 39, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 148, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100091064720, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP4 2DX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "IPSWICH", "built_form": 2, "created_at": "2018-03-22 21:17:12.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor maisonette", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "118, Old Foundry Road", "assessment_type": "RdSAP", "completion_date": "2018-03-22", "inspection_date": "2017-11-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.0, "quantity": "metres"}}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-03-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 500, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 4.0, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 30, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 20, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 696, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 280, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 61}], "co2_emissions_potential": 2.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 189, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 130, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 139, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1608, "impact_of_solid_wall_insulation": -3716, "space_heating_existing_dwelling": 7779}, "energy_consumption_current": 596, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 315, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 101, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": null, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HA8 7JG", "hot_water": {"description": "Community scheme, no cylinder thermostat", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 1}, "post_town": "EDGWARE", "built_form": 6, "created_at": "2018-04-18 16:23:19.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 950, "water_heating_fuel": 25, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "99a Station Road", "assessment_type": "RdSAP", "completion_date": "2018-04-18", "inspection_date": "2017-09-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 6.17}, "total_floor_area": 29, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-04-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.7952, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 380, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 28.5, "quantity": "square metres"}, "party_wall_length": {"value": 12.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 518, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 25, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 125, "currency": "GBP"}, "hot_water_cost_current": {"value": 211, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 225, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 36}, {"sequence": 2, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 36}, {"sequence": 3, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 41}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 26, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 252, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 209, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "hot_water_cost_potential": {"value": 211, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3740, "impact_of_solid_wall_insulation": -1589, "space_heating_existing_dwelling": 3310}, "energy_consumption_current": 959, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r02", "energy_consumption_potential": 699, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "E", "environmental_impact_potential": 41, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 162, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100010496644, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA4 5TF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MORECAMBE", "built_form": 2, "created_at": "2018-02-21 17:38:09.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16136}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "16, Thomas Grove", "assessment_type": "RdSAP", "completion_date": "2018-02-21", "inspection_date": "2018-02-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 236, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 31, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 215, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1653, "space_heating_existing_dwelling": 2751}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 165, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 766273435, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 53% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "LU7 9DN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEIGHTON BUZZARD", "built_form": 1, "created_at": "2018-03-01 22:58:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 130, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Swan Close", "address_line_2": "Ivinghoe Aston", "assessment_type": "RdSAP", "completion_date": "2018-03-01", "inspection_date": "2018-03-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 117, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-03-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 275, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 66.64, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 34.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 49.95, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 635, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 546, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 75, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 56}, {"sequence": 5, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 64}], "co2_emissions_potential": 4.1, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2284, "impact_of_loft_insulation": -686, "space_heating_existing_dwelling": 13433}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 119, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 32, "current_energy_efficiency_band": "D", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 100090607790, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO16 8AP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CLACTON-ON-SEA", "built_form": 2, "created_at": "2018-09-19 13:41:43.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16374}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Kersey Drive", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.57, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 39.16, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 537, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 75}}], "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2080, "impact_of_loft_insulation": -403, "impact_of_cavity_insulation": -2375, "space_heating_existing_dwelling": 9648}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 82, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100120006732, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BA2 2JN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BATH", "built_form": 4, "created_at": "2018-12-10 13:43:10.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8517}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Coronation Avenue", "assessment_type": "RdSAP", "completion_date": "2018-12-10", "inspection_date": "2018-12-10", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 121, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-12-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 13.62, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "K"}, "roof_construction": 5, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.89, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 22.59, "quantity": "square metres"}, "party_wall_length": {"value": 10.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1.95, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 22.59, "quantity": "square metres"}, "party_wall_length": {"value": 10.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 1.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.63, "quantity": "square metres"}, "party_wall_length": 4.46, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 9.63, "quantity": "square metres"}, "party_wall_length": 4.46, "heat_loss_perimeter": {"value": 4.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 2, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.01, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.37, "quantity": "square metres"}, "party_wall_length": 3.14, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.49, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 7.37, "quantity": "square metres"}, "party_wall_length": 3.14, "heat_loss_perimeter": {"value": 5.49, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 7.37, "quantity": "square metres"}, "party_wall_length": {"value": 3.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1345, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 758, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 441, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 7, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 76, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 263, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2290, "impact_of_loft_insulation": -2058, "impact_of_solid_wall_insulation": -7262, "space_heating_existing_dwelling": 19097}, "energy_consumption_current": 335, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 132, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100031545729, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG8 6FY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-04-07 09:10:39", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Fenwick Road", "assessment_type": "RdSAP", "completion_date": "2018-04-07", "inspection_date": "2018-03-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 486, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 422, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2681, "impact_of_loft_insulation": -507, "space_heating_existing_dwelling": 5963}, "energy_consumption_current": 168, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 116, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 200003372071, "roofs": [{"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE1 5TY", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-06 10:02:28.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat L", "address_line_2": "204, Old Kent Road", "assessment_type": "RdSAP", "completion_date": "2018-11-06", "inspection_date": "2018-11-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 38.61, "quantity": "square metres"}, "party_wall_length": {"value": 18.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 691, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 146, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 453, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.8, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 196, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 131, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1482, "space_heating_existing_dwelling": 4720}, "energy_consumption_current": 508, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 274, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 86, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090803262, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NR6 7JP", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "NORWICH", "built_form": 4, "created_at": "2018-03-22 20:01:39.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "15, Desmond Drive", "assessment_type": "RdSAP", "completion_date": "2018-03-22", "inspection_date": "2018-01-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 44.6, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 44.6, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 737, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 511, "currency": "GBP"}, "hot_water_cost_current": {"value": 262, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 43}, {"sequence": 2, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "\u00a32,000 - \u00a33,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 402, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 295, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2874, "space_heating_existing_dwelling": 8240}, "energy_consumption_current": 396, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 198, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10002660608, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN5 7QY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WADHURST", "built_form": 2, "created_at": "2018-10-29 21:03:54.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15016}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "21, The Warren", "address_line_2": "Ticehurst", "assessment_type": "RdSAP", "completion_date": "2018-10-29", "inspection_date": "2018-10-29", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 74, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-10-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 18.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 43.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 401, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 372, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2755, "space_heating_existing_dwelling": 6509}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 82, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10003305189, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL15 8EA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LAUNCESTON", "built_form": 3, "created_at": "2018-05-04 12:01:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10558}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Dutson Terrace", "assessment_type": "RdSAP", "completion_date": "2018-05-04", "inspection_date": "2018-04-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.55, "quantity": "square metres"}, "party_wall_length": {"value": 6.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.82, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 36.68, "quantity": "square metres"}, "party_wall_length": {"value": 6.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.98, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 508, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 424, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2093, "space_heating_existing_dwelling": 6983}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 83, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 38180062, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L12 5HW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 2, "created_at": "2018-05-21 21:21:50.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 112, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, West Derby Village", "assessment_type": "RdSAP", "completion_date": "2018-05-21", "inspection_date": "2018-05-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-05-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.23, "quantity": "square metres"}, "party_wall_length": {"value": 4.62, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.77, "quantity": "metres"}, "total_floor_area": {"value": 34.23, "quantity": "square metres"}, "party_wall_length": {"value": 4.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.88, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.18, "quantity": "square metres"}, "party_wall_length": {"value": 3.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.98, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1139, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 394, "currency": "GBP"}, "hot_water_cost_current": {"value": 126, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 9, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 10, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 11, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 127, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2116, "impact_of_loft_insulation": -2678, "impact_of_cavity_insulation": -471, "impact_of_solid_wall_insulation": -3893, "space_heating_existing_dwelling": 16509}, "energy_consumption_current": 442, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 78, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 68161034, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH1 6TE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "REDHILL", "built_form": 6, "created_at": "2018-06-29 09:43:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1707}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 22", "address_line_2": "Victoria Court", "address_line_3": "Royal Earlswood Park", "assessment_type": "RdSAP", "completion_date": "2018-06-29", "inspection_date": "2018-06-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 101, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-06-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 730, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 101.34, "quantity": "square metres"}, "party_wall_length": {"value": 42.119999, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 351, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 294, "currency": "GBP"}, "hot_water_cost_current": {"value": 158, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 25, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2702, "space_heating_existing_dwelling": 4290}, "energy_consumption_current": 139, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 111, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 38087906, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "L15 2HS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-08-30 17:01:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17325}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "19, Langton Road", "address_line_2": "Wavertree", "assessment_type": "RdSAP", "completion_date": "2018-08-30", "inspection_date": "2018-08-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-08-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.7, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.9, "quantity": "metres"}, "total_floor_area": {"value": 37.7, "quantity": "square metres"}, "party_wall_length": {"value": 17.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 334, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 5, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.9, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2064, "impact_of_loft_insulation": -501, "impact_of_solid_wall_insulation": -2808, "space_heating_existing_dwelling": 9137}, "energy_consumption_current": 223, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 63, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100110681329, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS20 2EL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOCKTON-ON-TEES", "built_form": 4, "created_at": "2018-10-08 15:54:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17702}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "100, Belle Vue Court", "assessment_type": "RdSAP", "completion_date": "2018-10-08", "inspection_date": "2018-10-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 47.2, "quantity": "square metres"}, "party_wall_length": {"value": 16.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 227, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.2, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 227, "currency": "GBP"}, "hot_water_cost_current": {"value": 71, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1574, "space_heating_existing_dwelling": 2279}, "energy_consumption_current": 147, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 147, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 5072241, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "access_issues": "true", "addendum_numbers": [1]}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NW1 2JL", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-09-30 22:14:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2306, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 14 Dalehead", "address_line_2": "Harrington Square", "assessment_type": "RdSAP", "completion_date": "2018-09-30", "inspection_date": "2018-09-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": 8.3}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.335, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 64.26, "quantity": "square metres"}, "party_wall_length": {"value": 9.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 364, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Charging system linked to use of community heating, programmer and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 368, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.4, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2043, "space_heating_existing_dwelling": 5252}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 210, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10022893007, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME14 2LG", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "MAIDSTONE", "built_form": 5, "created_at": "2018-04-04 14:15:01.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 36", "address_line_2": "Lee Heights", "address_line_3": "Bambridge Court", "assessment_type": "RdSAP", "completion_date": "2018-04-04", "inspection_date": "2018-04-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.93, "quantity": "metres"}}, "total_floor_area": 79, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-04-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.32468, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.276, "quantity": "metres"}, "total_floor_area": {"value": 79.339, "quantity": "square metres"}, "party_wall_length": {"value": 12.746, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.293, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 209, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 113, "currency": "GBP"}, "hot_water_cost_current": {"value": 319, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 251, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 310, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 267, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 87, "environmental_impact_rating": 88}], "hot_water_cost_potential": {"value": 158, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1979, "space_heating_existing_dwelling": 1298}, "energy_consumption_current": 142, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 146, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 200002815677, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "UB8 1LL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UXBRIDGE", "built_form": 4, "created_at": "2018-04-17 20:01:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 3", "address_line_2": "184a, High Street", "assessment_type": "RdSAP", "completion_date": "2018-04-17", "inspection_date": "2018-04-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-04-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.8, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 48.51, "quantity": "square metres"}, "party_wall_length": {"value": 15.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 323, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 295, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1878, "impact_of_cavity_insulation": -359, "impact_of_solid_wall_insulation": -640, "space_heating_existing_dwelling": 4704}, "energy_consumption_current": 213, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 195, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100051229371, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD12 0HU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRADFORD", "built_form": 3, "created_at": "2018-03-20 18:06:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8348}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "17, Tordoff Road", "address_line_2": "Low Moor", "assessment_type": "RdSAP", "completion_date": "2018-03-20", "inspection_date": "2018-03-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.156, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.998, "quantity": "square metres"}, "party_wall_length": {"value": 6.841, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.676, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.011, "quantity": "metres"}, "total_floor_area": {"value": 23.998, "quantity": "square metres"}, "party_wall_length": {"value": 6.841, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.676, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.912, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.483, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.072, "quantity": "metres"}, "total_floor_area": {"value": 8.912, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 8.483, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 949, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 513, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 216, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 7, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 63}], "hot_water_cost_potential": {"value": 47, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1945, "impact_of_loft_insulation": -785, "impact_of_cavity_insulation": -1679, "impact_of_solid_wall_insulation": -4030, "space_heating_existing_dwelling": 15297}, "energy_consumption_current": 455, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 149, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100070320283, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B30 2BS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2018-03-21 15:54:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17507}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "64, Charlotte Road", "address_line_2": "Stirchley", "assessment_type": "RdSAP", "completion_date": "2018-03-21", "inspection_date": "2018-03-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-03-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 24.42, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 12.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 934, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 67, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 532, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 341, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1926, "impact_of_loft_insulation": -1343, "impact_of_solid_wall_insulation": -6984, "space_heating_existing_dwelling": 16447}, "energy_consumption_current": 390, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 141, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100022622165, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW15 6EW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-12 12:34:35.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9158}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 22", "address_line_2": "12 Cambalt Road", "assessment_type": "RdSAP", "completion_date": "2018-11-12", "inspection_date": "2018-11-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-11-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.8, "quantity": "square metres"}, "party_wall_length": {"value": 10.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 434, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 209, "currency": "GBP"}, "hot_water_cost_current": {"value": 80, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1515, "impact_of_solid_wall_insulation": -2459, "space_heating_existing_dwelling": 6410}, "energy_consumption_current": 370, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.08r07", "energy_consumption_potential": 164, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 65, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100023278648, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE6 4XD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-01-16 10:47:45.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "310, Stanstead Road", "assessment_type": "RdSAP", "completion_date": "2018-01-16", "inspection_date": "2018-01-15", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.03, "quantity": "metres"}}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-01-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.8016, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 90, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 41.22, "quantity": "square metres"}, "party_wall_length": {"value": 16.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 17.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.95, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 375, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 302, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1665, "impact_of_loft_insulation": -1648, "impact_of_solid_wall_insulation": -1827, "space_heating_existing_dwelling": 5545}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 151, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100062476433, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RH12 1TP", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "HORSHAM", "built_form": 1, "created_at": "2018-01-01 13:02:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "29, Pelham Court", "address_line_2": "Bishopric", "assessment_type": "RdSAP", "completion_date": "2018-01-01", "inspection_date": "2018-01-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.4, "quantity": "metres"}}, "total_floor_area": 60, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.21, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.94, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 842, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 382, "currency": "GBP"}, "hot_water_cost_current": {"value": 148, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 218, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 139, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 53}], "co2_emissions_potential": 3.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 245, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 155, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 77}], "hot_water_cost_potential": {"value": 148, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1829, "impact_of_cavity_insulation": -2469, "space_heating_existing_dwelling": 9431}, "energy_consumption_current": 605, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 340, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 53, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 102, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100090148673, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB24 9PG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 1, "created_at": "2018-10-18 17:04:25.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "31, Lone Tree Avenue", "address_line_2": "Impington", "assessment_type": "RdSAP", "completion_date": "2018-10-18", "inspection_date": "2018-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.69, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 41.69, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 597, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 437, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2159, "impact_of_loft_insulation": -386, "impact_of_cavity_insulation": -2688, "space_heating_existing_dwelling": 11011}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 95, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 42077077, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CH63 9NT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WIRRAL", "built_form": 2, "created_at": "2018-02-01 15:41:41.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 768}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "26, Moseley Road", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-02-01", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.93, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 32.93, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 699, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 87, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 7, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1946, "impact_of_cavity_insulation": -2167, "space_heating_existing_dwelling": 8955}, "energy_consumption_current": 356, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 99, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10012901346, "roofs": [{"description": {"value": "Roof room(s), insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO21 1XF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WHITBY", "built_form": 1, "created_at": "2018-07-18 13:59:20.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1869}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Beckside Farm", "address_line_2": "Egton Bridge", "assessment_type": "RdSAP", "completion_date": "2018-07-18", "inspection_date": "2018-07-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 174, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-07-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 55, "quantity": "square metres"}, "insulation": 3, "roof_room_connected": "N", "construction_age_band": "A", "roof_insulation_thickness": "50mm"}, "roof_construction": 8, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 35, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 55.6, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 30, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "100mm"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1617, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 14, "energy_rating_average": 60, "energy_rating_current": 41, "lighting_cost_current": {"value": 107, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 697, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 115, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 475, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 130, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}, {"sequence": 8, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 93, "environmental_impact_rating": 85}], "co2_emissions_potential": 3.5, "energy_rating_potential": 93, "lighting_cost_potential": {"value": 109, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3005, "impact_of_solid_wall_insulation": -10625, "space_heating_existing_dwelling": 36353}, "energy_consumption_current": 305, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 44, "environmental_impact_current": 35, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10010747707, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 90% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SK13 1DP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GLOSSOP", "built_form": 1, "created_at": "2018-04-10 19:20:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16919}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "21, Vale Mount", "address_line_2": "Hadfield", "assessment_type": "RdSAP", "completion_date": "2018-04-10", "inspection_date": "2018-04-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.02, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 35.62, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 541, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 516, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 262, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1953, "space_heating_existing_dwelling": 8971}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 136, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10009555558, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 24% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "HR6 0EB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEOMINSTER", "built_form": 1, "created_at": "2018-08-17 17:23:38", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15230}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Barn Orchard", "address_line_2": "Luston", "assessment_type": "RdSAP", "completion_date": "2018-08-17", "inspection_date": "2018-08-17", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 154, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-08-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 103.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.19, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.13, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.41, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.84, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.37, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 24, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 726, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 155, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 618, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 72}], "co2_emissions_potential": 3.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 88, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2776, "impact_of_loft_insulation": -663, "space_heating_existing_dwelling": 15517}, "energy_consumption_current": 171, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 99, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100011413033, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "M7 3QR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SALFORD", "built_form": 4, "created_at": "2018-11-15 11:14:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "3, Linton Walk", "assessment_type": "RdSAP", "completion_date": "2018-11-15", "inspection_date": "2018-11-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 170, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.55, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 43.55, "quantity": "square metres"}, "party_wall_length": {"value": 13.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 442, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 418, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2166, "space_heating_existing_dwelling": 6980}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 95, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100031207215, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NN8 4QS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WELLINGBOROUGH", "built_form": 4, "created_at": "2018-07-07 12:20:01.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15833}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "47, North Street", "assessment_type": "RdSAP", "completion_date": "2018-07-07", "inspection_date": "2018-07-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.37, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.25, "quantity": "square metres"}, "party_wall_length": {"value": 9.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.5, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 681, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 99, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 204, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2144, "impact_of_solid_wall_insulation": -4488, "space_heating_existing_dwelling": 12463}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 92, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 148039893, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EN10 6FN", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "BROXBOURNE", "built_form": 2, "created_at": "2018-03-29 15:11:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "8, Yukon Road", "assessment_type": "RdSAP", "completion_date": "2018-03-29", "inspection_date": "2018-03-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": 9.2}, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-03-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.252, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 73.24, "quantity": "square metres"}, "party_wall_length": {"value": 15.77, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.89, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 306, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 212, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 10, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1856, "impact_of_loft_insulation": -607, "space_heating_existing_dwelling": 3364}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 197, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050546402, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO10 4HY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 2, "created_at": "2018-08-10 13:39:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "95, Danum Road", "assessment_type": "RdSAP", "completion_date": "2018-08-10", "inspection_date": "2018-08-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-08-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.9, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 5.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 789, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 638, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2249, "impact_of_loft_insulation": -320, "impact_of_cavity_insulation": -2152, "space_heating_existing_dwelling": 13632}, "energy_consumption_current": 251, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 143, "environmental_impact_current": 58, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100010466327, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [6]}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LA1 3AA", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LANCASTER", "built_form": 4, "created_at": "2018-11-07 19:45:33.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2605, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "52, Golgotha Road", "assessment_type": "RdSAP", "completion_date": "2018-11-07", "inspection_date": "2018-11-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-11-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 315, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.48, "quantity": "square metres"}, "party_wall_length": {"value": 13.38, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.58, "quantity": "metres"}, "total_floor_area": {"value": 38.38, "quantity": "square metres"}, "party_wall_length": {"value": 13.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.98, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.4, "quantity": "square metres"}, "party_wall_length": {"value": 4.55, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1238, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 650, "currency": "GBP"}, "hot_water_cost_current": {"value": 369, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 688, "currency": "GBP"}, "indicative_cost": "3,600", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 51}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 63}], "co2_emissions_potential": 3.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 83, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 924, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 810, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2228, "space_heating_existing_dwelling": 7479}, "energy_consumption_current": 308, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 95, "calculation_software_version": "3.08r07", "energy_consumption_potential": 218, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100090126459, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PE8 6RQ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "PETERBOROUGH", "built_form": 4, "created_at": "2018-10-04 11:39:13.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 404, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "29, Duck Street", "address_line_2": "Elton", "assessment_type": "RdSAP", "completion_date": "2018-10-04", "inspection_date": "2018-10-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-10-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.46, "quantity": "square metres"}, "party_wall_length": {"value": 4.57, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.78, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 26.46, "quantity": "square metres"}, "party_wall_length": {"value": 9.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.42, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.97, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.16, "quantity": "metres"}, "total_floor_area": {"value": 14.42, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1483, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 525, "currency": "GBP"}, "hot_water_cost_current": {"value": 205, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 146, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 23}, {"sequence": 2, "typical_saving": {"value": 561, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 46}, {"sequence": 5, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 49}, {"sequence": 6, "typical_saving": {"value": 170, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 59}, {"sequence": 7, "typical_saving": {"value": 322, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2142, "impact_of_loft_insulation": -301, "impact_of_solid_wall_insulation": -6290, "space_heating_existing_dwelling": 16789}, "energy_consumption_current": 724, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.08r07", "energy_consumption_potential": 204, "environmental_impact_current": 19, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 122, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100080813188, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 54% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SG6 2JX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LETCHWORTH GARDEN CITY", "built_form": 4, "created_at": "2018-07-18 00:19:37.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10444}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "23, Chatterton", "assessment_type": "RdSAP", "completion_date": "2018-07-18", "inspection_date": "2018-07-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.26, "quantity": "square metres"}, "party_wall_length": {"value": 14.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.43, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 44.26, "quantity": "square metres"}, "party_wall_length": {"value": 14.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 170, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 54, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 540, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2209, "impact_of_solid_wall_insulation": -795, "space_heating_existing_dwelling": 9438}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 85, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 44024650, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME1 2HD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "ROCHESTER", "built_form": 4, "created_at": "2018-10-20 16:53:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "28, Longley Road", "assessment_type": "RdSAP", "completion_date": "2018-10-20", "inspection_date": "2018-10-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-10-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 23, "insulation": 4, "roof_room_connected": "N", "construction_age_band": "L", "roof_insulation_thickness": "150mm"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.66, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.59, "quantity": "square metres"}, "party_wall_length": {"value": 17.87, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 28.46, "quantity": "square metres"}, "party_wall_length": {"value": 14.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.26, "quantity": "square metres"}, "party_wall_length": {"value": 3.03, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.15, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 504, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 86, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2436, "impact_of_solid_wall_insulation": -1655, "space_heating_existing_dwelling": 8902}, "energy_consumption_current": 184, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 88, "calculation_software_version": "3.08r07", "energy_consumption_potential": 85, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 200004380011, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN25 4LJ", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ASHFORD", "built_form": 6, "created_at": "2018-02-22 16:44:47.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 9, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 0.3, "sap_main_heating_code": 633, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.7, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}, {"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2 Malthouse Cottage", "address_line_2": "Westwell", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.09, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.02, "quantity": "square metres"}, "party_wall_length": {"value": 9.09, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.08, "quantity": "metres"}, "total_floor_area": {"value": 32.73, "quantity": "square metres"}, "party_wall_length": {"value": 8.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.57, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.09, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.61, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.09, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.87, "quantity": "square metres"}, "party_wall_length": {"value": 4.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.78, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1551, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 29, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1021, "currency": "GBP"}, "hot_water_cost_current": {"value": 309, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 21}, {"sequence": 2, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 29}, {"sequence": 3, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 32}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 32}, {"sequence": 5, "typical_saving": {"value": 119, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 34}, {"sequence": 6, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 35}, {"sequence": 7, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 41}], "co2_emissions_potential": 5.6, "energy_rating_potential": 61, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 158, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2178, "impact_of_loft_insulation": -4792, "impact_of_solid_wall_insulation": -3932, "space_heating_existing_dwelling": 18429}, "energy_consumption_current": 660, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 358, "environmental_impact_current": 18, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "F", "environmental_impact_potential": 41, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 117, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 200003407786, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE16 3EZ", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-06-19 22:56:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 408, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 82", "address_line_2": "8, Rossetti Road", "assessment_type": "RdSAP", "completion_date": "2018-06-19", "inspection_date": "2018-06-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8.46, "quantity": "metres"}}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.304, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.12, "quantity": "square metres"}, "party_wall_length": {"value": 4.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 438, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 324, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 114, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}], "co2_emissions_potential": 2.8, "energy_rating_potential": 70, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 133, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1812, "space_heating_existing_dwelling": 4556}, "energy_consumption_current": 405, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 332, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 69, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080814428, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SG6 2LS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LETCHWORTH GARDEN CITY", "built_form": 4, "created_at": "2018-07-03 22:28:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16183}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "20, Fleetwood", "assessment_type": "RdSAP", "completion_date": "2018-07-03", "inspection_date": "2018-07-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-07-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.12, "quantity": "square metres"}, "party_wall_length": {"value": 13.54, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 41.12, "quantity": "square metres"}, "party_wall_length": {"value": 13.54, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.36, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 532, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 410, "currency": "GBP"}, "hot_water_cost_current": {"value": 122, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 80, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2643, "impact_of_loft_insulation": -248, "impact_of_solid_wall_insulation": -1211, "space_heating_existing_dwelling": 9545}, "energy_consumption_current": 208, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 85, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100060745693, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 21% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SO18 6AW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 2, "created_at": "2018-04-07 13:07:03.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "1, Yew Road", "assessment_type": "RdSAP", "completion_date": "2018-04-07", "inspection_date": "2018-04-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.55, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 38.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.55, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 21, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 393, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 361, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 75, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2080, "space_heating_existing_dwelling": 6234}, "energy_consumption_current": 180, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 66, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100080022920, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 19% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "MK41 8RP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 1, "created_at": "2018-03-23 13:34:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2105, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 17007}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and underfloor heating, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "6, Kimbolton Close", "assessment_type": "RdSAP", "completion_date": "2018-03-23", "inspection_date": "2018-03-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 327, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2018-03-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 122.74, "insulation": "AB", "roof_room_connected": "Y", "construction_age_band": "H"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 149.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 40.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.37, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 8.67, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 19, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 1384, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 248, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and at least two room thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1187, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": 130, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 76}], "co2_emissions_potential": 6.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 137, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2866, "impact_of_loft_insulation": -474, "space_heating_existing_dwelling": 29373}, "energy_consumption_current": 146, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 104, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 32, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 503243, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true"}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS34 5EQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2018-01-14 09:28:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Cavendish Road", "address_line_2": "Patchway", "assessment_type": "RdSAP", "completion_date": "2018-01-14", "inspection_date": "2018-01-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-01-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 48.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 700, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 667, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2227, "space_heating_existing_dwelling": 12428}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 154, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100080361656, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SL6 3DE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MAIDENHEAD", "built_form": 2, "created_at": "2018-10-29 07:30:59.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15445}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "102, Northumbria Road", "assessment_type": "RdSAP", "completion_date": "2018-10-29", "inspection_date": "2018-10-28", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 6.2}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.26, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 69.2, "quantity": "square metres"}, "party_wall_length": {"value": 3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 326, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.9, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1991, "impact_of_cavity_insulation": -233, "space_heating_existing_dwelling": 4807}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 158, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 3455011275, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 45% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ST2 8HN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2018-09-04 12:15:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8421}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "101, Blakelow Road", "assessment_type": "RdSAP", "completion_date": "2018-09-04", "inspection_date": "2018-09-03", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.9, "quantity": "square metres"}, "party_wall_length": {"value": 4.33, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 22.68, "quantity": "square metres"}, "party_wall_length": {"value": 4.33, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.57, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.35, "quantity": "square metres"}, "party_wall_length": {"value": 2.93, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.17, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 15.35, "quantity": "square metres"}, "party_wall_length": {"value": 2.93, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.17, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 45, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 601, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 570, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.9, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2073, "space_heating_existing_dwelling": 8676}, "energy_consumption_current": 241, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 138, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100021404011, "roofs": [{"description": {"value": "Pitched, 25 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RM14 1QU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "UPMINSTER", "built_form": 2, "created_at": "2018-09-06 15:12:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Avon Road", "assessment_type": "RdSAP", "completion_date": "2018-09-06", "inspection_date": "2018-09-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.16, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 39.16, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 647, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 365, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 193, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2207, "impact_of_loft_insulation": -1373, "impact_of_solid_wall_insulation": -4369, "space_heating_existing_dwelling": 11974}, "energy_consumption_current": 267, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 70, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100022242852, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IG6 1PT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-12-15 18:39:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17233}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "21, Virginia Gardens", "assessment_type": "RdSAP", "completion_date": "2018-12-15", "inspection_date": "2018-12-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-12-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.58, "quantity": "square metres"}, "party_wall_length": {"value": 16.37, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 46.58, "quantity": "square metres"}, "party_wall_length": {"value": 16.37, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 502, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 417, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2054, "impact_of_loft_insulation": -444, "impact_of_cavity_insulation": -1343, "space_heating_existing_dwelling": 8835}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 78, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100040475982, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 71% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL7 4ND", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 2, "created_at": "2018-02-20 21:53:20.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "108, Plymouth Road", "address_line_2": "Plympton", "assessment_type": "RdSAP", "completion_date": "2018-02-20", "inspection_date": "2018-02-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 11, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2018-02-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 18.56, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.46, "quantity": "square metres"}, "party_wall_length": {"value": 7.34, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 32.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 901, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 403, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 218, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 176, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 80, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 7, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2198, "impact_of_solid_wall_insulation": -3139, "space_heating_existing_dwelling": 15543}, "energy_consumption_current": 319, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 74, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050726094, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "DN4 9DD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DONCASTER", "built_form": 1, "created_at": "2018-02-01 14:55:32.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15030}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "33, Galsworthy Close", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-02-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 3.547}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.292886, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.338, "quantity": "metres"}, "total_floor_area": {"value": 47.045, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.436, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 280, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 283, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.5, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1654, "impact_of_cavity_insulation": -129, "space_heating_existing_dwelling": 3723}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 185, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10034489038, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S18 2DA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DRONFIELD", "built_form": 1, "created_at": "2018-03-09 18:02:43.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "35, Frithwood Drive", "assessment_type": "RdSAP", "completion_date": "2018-03-09", "inspection_date": "2018-03-08", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-03-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 49.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.58, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.02, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 590, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 110, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 598, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 268, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.5, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2794, "impact_of_loft_insulation": -658, "space_heating_existing_dwelling": 10769}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 129, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100031739522, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST5 1NF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "NEWCASTLE", "built_form": 4, "created_at": "2018-03-27 14:45:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1135}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Slaney Street", "assessment_type": "RdSAP", "completion_date": "2018-03-27", "inspection_date": "2018-03-27", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.84, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 33.95, "quantity": "square metres"}, "party_wall_length": {"value": 7.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 265, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 285, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.68, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1023, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 500, "currency": "GBP"}, "hot_water_cost_current": {"value": 211, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 7, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 9, "typical_saving": {"value": 165, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 10, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 11, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 53, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 114, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 92}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 200, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3236, "impact_of_loft_insulation": -424, "impact_of_cavity_insulation": -815, "impact_of_solid_wall_insulation": -3114, "space_heating_existing_dwelling": 14731}, "energy_consumption_current": 406, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 26, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 26} +{"uprn": 12189180, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W5 2AL", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-03-29 15:33:24.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 7", "address_line_2": "93 Gordon Road", "assessment_type": "RdSAP", "completion_date": "2018-03-29", "inspection_date": "2018-03-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 21, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-03-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.95, "quantity": "metres"}, "total_floor_area": {"value": 21.29, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 381, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 20, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 278, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 63}], "co2_emissions_potential": 1.7, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 20, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1627, "impact_of_loft_insulation": -1911, "impact_of_solid_wall_insulation": -1934, "space_heating_existing_dwelling": 5214}, "energy_consumption_current": 595, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 441, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120038102, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS14 0PH", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-01-31 23:37:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "14, Maggs Lane", "address_line_2": "Whitchurch", "assessment_type": "RdSAP", "completion_date": "2018-01-31", "inspection_date": "2018-01-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-31", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 38.96, "quantity": "square metres"}, "party_wall_length": {"value": 7.35, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 787, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 535, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 174, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 61}], "co2_emissions_potential": 3.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 259, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 238, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1896, "space_heating_existing_dwelling": 8802}, "energy_consumption_current": 435, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 231, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 61, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 74, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10002511682, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF5 2JF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 4, "created_at": "2018-02-01 17:53:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18275}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and underfloor heating, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "29 Ely Road", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-01-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.2, "quantity": "metres"}}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.792, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 40.53, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 495, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 243, "currency": "GBP"}, "hot_water_cost_current": {"value": 72, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 223, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.3, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1587, "impact_of_loft_insulation": -4889, "impact_of_cavity_insulation": -659, "space_heating_existing_dwelling": 8227}, "energy_consumption_current": 372, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 177, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 12067540, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W13 9ER", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-09-19 06:39:10.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17821}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Hessel Road", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 2, "conservatory_type": 4, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 6.08, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 5.1, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.74, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 31.74, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.45, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 9.45, "quantity": "square metres"}, "party_wall_length": {"value": 3.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 697, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 452, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 189, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2751, "impact_of_loft_insulation": -259, "impact_of_solid_wall_insulation": -4193, "space_heating_existing_dwelling": 13140}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 99, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100091415124, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB22 3AR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "CAMBRIDGE", "built_form": 2, "created_at": "2018-02-12 11:12:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1872}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "2 Home Farm Cottage", "address_line_2": "High Street", "address_line_3": "Babraham", "assessment_type": "RdSAP", "completion_date": "2018-02-12", "inspection_date": "2018-02-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.16, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 42.16, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 481, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 400, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 7, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2836, "space_heating_existing_dwelling": 7157}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 86, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100012391339, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PR4 1RG", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "PRESTON", "built_form": 4, "created_at": "2018-02-08 15:25:54.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 33 Croft Manor", "address_line_2": "Mason Close", "address_line_3": "Freckleton", "assessment_type": "RdSAP", "completion_date": "2018-02-08", "inspection_date": "2018-02-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 42, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 42.14, "quantity": "square metres"}, "party_wall_length": {"value": 19.22, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.92, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 298, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 186, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}], "co2_emissions_potential": 1.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 165, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 122, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 173, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 971, "space_heating_existing_dwelling": 3274}, "energy_consumption_current": 335, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 243, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 47021686, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 90% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE23 7PN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CRAMLINGTON", "built_form": 2, "created_at": "2018-02-12 08:26:54.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8214}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "16, Cheviot Grange", "address_line_2": "Burradon", "assessment_type": "RdSAP", "completion_date": "2018-02-12", "inspection_date": "2018-02-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.11, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 33.11, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 468, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 88}], "co2_emissions_potential": 1.0, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 57, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1951, "space_heating_existing_dwelling": 5855}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 87, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100120752986, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DY10 3DW", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "KIDDERMINSTER", "built_form": 2, "created_at": "2018-04-04 16:15:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "5, Somerleyton Court", "assessment_type": "RdSAP", "completion_date": "2018-04-04", "inspection_date": "2018-03-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 7.21}, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-04-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.9435, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 5, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.41, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 542, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 314, "currency": "GBP"}, "hot_water_cost_current": {"value": 185, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 138, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 59}], "co2_emissions_potential": 3.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 185, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 170, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 143, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1927, "impact_of_cavity_insulation": -340, "space_heating_existing_dwelling": 6040}, "energy_consumption_current": 422, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 304, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100011448753, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SK8 7LD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHEADLE", "built_form": 2, "created_at": "2018-11-06 18:29:21.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15709}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "27, Woodstock Avenue", "address_line_2": "Cheadle Hulme", "assessment_type": "RdSAP", "completion_date": "2018-11-06", "inspection_date": "2018-11-06", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-11-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 68.44, "quantity": "square metres"}, "party_wall_length": {"value": 8.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.26, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 0.77, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 0.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.51, "quantity": "metres"}, "total_floor_area": {"value": 0.77, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 0.88, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 343, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 346, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.0, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "space_heating_existing_dwelling": 4995}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 165, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100020213738, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 36% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DA6 7AJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BEXLEYHEATH", "built_form": 2, "created_at": "2018-09-18 11:05:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 118, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "22, Oaklands Road", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-17", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.32, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.16, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 33.2, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.8, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 10.8, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.86, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1299, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 571, "currency": "GBP"}, "hot_water_cost_current": {"value": 139, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 41}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 170, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 5, "typical_saving": {"value": 206, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 2.3, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 99, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 248, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2208, "impact_of_loft_insulation": -2790, "impact_of_solid_wall_insulation": -5716, "space_heating_existing_dwelling": 18372}, "energy_consumption_current": 463, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 134, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 82, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050806708, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S64 8EY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MEXBOROUGH", "built_form": 2, "created_at": "2018-02-13 11:10:40.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10315}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Brookside", "address_line_2": "Swinton", "assessment_type": "RdSAP", "completion_date": "2018-02-13", "inspection_date": "2018-02-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-02-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.42, "quantity": "square metres"}, "party_wall_length": {"value": 5.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 39.42, "quantity": "square metres"}, "party_wall_length": {"value": 5.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 556, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 510, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2099, "space_heating_existing_dwelling": 7835}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 118, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10092964077, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TW20 0QS", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "EGHAM", "built_form": 1, "created_at": "2018-06-07 09:38:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Basement flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Basement Flat", "address_line_2": "15 Harvest Road", "address_line_3": "Englefield Green", "assessment_type": "RdSAP", "completion_date": "2018-06-07", "inspection_date": "2018-05-25", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 0}, "total_floor_area": 27, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "200mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 402, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 22, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 156, "currency": "GBP"}, "hot_water_cost_current": {"value": 217, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 127, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 220, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 67}], "co2_emissions_potential": 1.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 25, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 275, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 245, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1383, "space_heating_existing_dwelling": 2563}, "energy_consumption_current": 465, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 358, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 200000635340, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 9% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HU19 2QX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WITHERNSEA", "built_form": 2, "created_at": "2018-03-07 12:49:59", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 17104}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1 Old Hive Cottages", "address_line_2": "Holmpton", "assessment_type": "RdSAP", "completion_date": "2018-03-07", "inspection_date": "2018-03-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-07", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.452, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.539, "quantity": "square metres"}, "party_wall_length": {"value": 5.175, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.815, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.409, "quantity": "metres"}, "total_floor_area": {"value": 42.539, "quantity": "square metres"}, "party_wall_length": {"value": 5.175, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.615, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.275, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.14, "quantity": "square metres"}, "party_wall_length": {"value": 2.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.1, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 9, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 514, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 443, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2866, "impact_of_loft_insulation": -388, "space_heating_existing_dwelling": 9515}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 105, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100080734446, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 56% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SG14 3BZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HERTFORD", "built_form": 2, "created_at": "2018-09-24 14:30:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2040}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "33, Duncombe Road", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 241, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 40.3, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 17.67, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 769, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 321, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 211, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 9, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 10, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2665, "impact_of_loft_insulation": -757, "impact_of_solid_wall_insulation": -4141, "space_heating_existing_dwelling": 12813}, "energy_consumption_current": 327, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 54, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100121051434, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SP2 8JL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SALISBURY", "built_form": 2, "created_at": "2018-09-24 14:16:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17733}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "29, Old Street", "assessment_type": "RdSAP", "completion_date": "2018-09-24", "inspection_date": "2018-09-21", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 340, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 298, "currency": "GBP"}, "hot_water_cost_current": {"value": 67, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1504, "space_heating_existing_dwelling": 5165}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 165, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200003273771, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 13% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LU2 0TP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LUTON", "built_form": 3, "created_at": "2018-02-26 11:33:44", "door_count": 3, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "5, Butterworth Path", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 2, "peak_power": 1.43, "orientation": 6, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.21, "quantity": "square metres"}, "party_wall_length": {"value": 1.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 32.32, "quantity": "square metres"}, "party_wall_length": {"value": 5.92, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.82, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 32.15, "quantity": "square metres"}, "party_wall_length": {"value": 2.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.04, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 560, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 524, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2222, "space_heating_existing_dwelling": 9708}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 129, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 200004178843, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB4 1EF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 3, "created_at": "2018-02-19 15:04:39.000000", "door_count": 1, "glazed_area": 3, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17145}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "9 New Court", "address_line_2": "Church Street", "assessment_type": "RdSAP", "completion_date": "2018-02-19", "inspection_date": "2018-02-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.3, "quantity": "metres"}}, "total_floor_area": 36, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.37, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.51, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 271, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 227, "currency": "GBP"}, "hot_water_cost_current": {"value": 60, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.1, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1337, "impact_of_cavity_insulation": -288, "space_heating_existing_dwelling": 3525}, "energy_consumption_current": 217, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 180, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100030202973, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S44 5BS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTERFIELD", "built_form": 2, "created_at": "2018-04-06 18:48:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 610, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "11, Hardwick Drive", "address_line_2": "Arkwright Town", "assessment_type": "RdSAP", "completion_date": "2018-04-06", "inspection_date": "2018-04-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 73.15, "quantity": "square metres"}, "party_wall_length": {"value": 8.95, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.47, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 566, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 439, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2039, "space_heating_existing_dwelling": 8332}, "energy_consumption_current": 257, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 111, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100100842643, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF64 3PS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PENARTH", "built_form": 3, "created_at": "2018-06-01 08:38:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "22, St. Lukes Avenue", "assessment_type": "RdSAP", "completion_date": "2018-06-01", "inspection_date": "2018-05-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 6.04}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 400, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.6504, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 230, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 70.18, "quantity": "square metres"}, "party_wall_length": {"value": 2.62, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.78, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 232, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 213, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2174, "impact_of_solid_wall_insulation": -416, "space_heating_existing_dwelling": 2654}, "energy_consumption_current": 115, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 107, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 20, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 14051726, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RG40 1RS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOKINGHAM", "built_form": 1, "created_at": "2018-06-07 14:06:33.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10464}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "4, Woodrow Drive", "assessment_type": "RdSAP", "completion_date": "2018-06-07", "inspection_date": "2018-06-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72.99, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 41.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 658, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 605, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 70}], "co2_emissions_potential": 2.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2749, "impact_of_loft_insulation": -3802, "space_heating_existing_dwelling": 12200}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 177, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 512755, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BS16 1RH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-12-15 13:07:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 14 Tanners Court", "address_line_2": "Bristol Road", "address_line_3": "Frenchay", "assessment_type": "RdSAP", "completion_date": "2018-12-15", "inspection_date": "2018-11-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7, "quantity": "metres"}}, "total_floor_area": 36, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-12-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_u_value": 1.5, "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.85, "wall_u_value": 1.5, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 215, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 130, "currency": "GBP"}, "hot_water_cost_current": {"value": 658, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 353, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 129, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4613, "impact_of_cavity_insulation": -1110, "space_heating_existing_dwelling": 2207}, "energy_consumption_current": 612, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 275, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 103, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 3455038679, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ST6 6HY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2018-10-04 11:48:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "3, Ford Avenue", "assessment_type": "RdSAP", "completion_date": "2018-10-04", "inspection_date": "2018-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 11, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.21, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 42.21, "quantity": "square metres"}, "party_wall_length": {"value": 6.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 631, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 590, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1903, "space_heating_existing_dwelling": 9248}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 128, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120865970, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG9 5AS", "hot_water": {"description": "Electric immersion, off-peak, plus solar", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 3}, "post_town": "HENLEY-ON-THAMES", "built_form": 2, "created_at": "2018-09-26 15:37:56", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230002, "number_of_heaters": 2, "high_heat_retention": "true"}, {"index_number": 230004, "number_of_heaters": 1, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "31, Priest Close", "address_line_2": "Nettlebed", "assessment_type": "RdSAP", "completion_date": "2018-09-26", "inspection_date": "2018-09-26", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 5.79}, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-09-26", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.01, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 190, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.09, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.72, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 190, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 2, "sap_alternative_wall": {"wall_area": 13.3749, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.23, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 2.62, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 190, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.65, "quantity": "square metres"}, "party_wall_length": {"value": 4.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "Y", "habitable_room_count": 3, "heating_cost_current": {"value": 560, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Controls for high heat retention storage heaters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 470, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 54}], "co2_emissions_potential": 3.3, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1868, "space_heating_existing_dwelling": 6224}, "energy_consumption_current": 423, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 360, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 54, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100061262966, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME8 9RA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "GILLINGHAM", "built_form": 4, "created_at": "2018-12-07 20:22:18.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "48, Lyall Way", "assessment_type": "RdSAP", "completion_date": "2018-12-07", "inspection_date": "2018-12-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.28, "wall_dry_lined": "N", "wall_thickness": 240, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.02, "quantity": "square metres"}, "party_wall_length": {"value": 13.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 35.02, "quantity": "square metres"}, "party_wall_length": {"value": 13.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 401, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 375, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2275, "impact_of_loft_insulation": -779, "impact_of_cavity_insulation": -612, "space_heating_existing_dwelling": 6543}, "energy_consumption_current": 192, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 83, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 74002775, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S41 8TN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHESTERFIELD", "built_form": 2, "created_at": "2018-02-23 13:22:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Racecourse Road", "assessment_type": "RdSAP", "completion_date": "2018-02-23", "inspection_date": "2018-02-23", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-02-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.75, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 48.75, "quantity": "square metres"}, "party_wall_length": {"value": 6.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 602, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 560, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.9, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2283, "space_heating_existing_dwelling": 8688}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 127, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100040033800, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true", "access_issues": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in 23% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "TR11 3EP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FALMOUTH", "built_form": 4, "created_at": "2018-04-23 10:02:41", "door_count": 2, "glazed_area": 2, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "32, Wodehouse Terrace", "assessment_type": "RdSAP", "completion_date": "2018-04-23", "inspection_date": "2018-04-19", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 150, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-04-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.67, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.79, "quantity": "square metres"}, "party_wall_length": {"value": 12.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 60.24, "quantity": "square metres"}, "party_wall_length": {"value": 12.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.18, "quantity": "metres"}, "total_floor_area": {"value": 5.32, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 120, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.67, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 1, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.69, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 23, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1208, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.6, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 144, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 777, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 213, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a385", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2319, "impact_of_loft_insulation": -1029, "impact_of_solid_wall_insulation": -3794, "space_heating_existing_dwelling": 19583}, "energy_consumption_current": 250, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 30, "calculation_software_version": "3.05r02", "energy_consumption_potential": 121, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 48059081, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"system_build": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CR4 4BX", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "MITCHAM", "built_form": 4, "created_at": "2018-05-04 11:48:49.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1993}], "immersion_heating_type": "NA", "cylinder_insulation_type": 0, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "63, Rawnsley Avenue", "assessment_type": "RdSAP", "completion_date": "2018-05-04", "inspection_date": "2018-05-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-05-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.02, "quantity": "square metres"}, "party_wall_length": {"value": 14.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 37.93, "quantity": "square metres"}, "party_wall_length": {"value": 21.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 37.93, "quantity": "square metres"}, "party_wall_length": {"value": 21.04, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 780, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 486, "currency": "GBP"}, "hot_water_cost_current": {"value": 444, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 1}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 5, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 7, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 8, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 143, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 7421, "space_heating_existing_dwelling": 12083}, "energy_consumption_current": 349, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r04", "energy_consumption_potential": 95, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 38098385, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "L6 6BH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIVERPOOL", "built_form": 4, "created_at": "2018-08-06 18:18:48.000000", "door_count": 2, "glazed_area": 4, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15834}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "sap_windows": [{"pvc_frame": "true", "glazing_gap": "16+", "orientation": 7, "window_area": {"value": 5.48, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "false", "orientation": 7, "window_area": {"value": 0.72, "quantity": "square metres"}, "window_type": 2, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 3.3, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 3, "window_area": {"value": 3.73, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 8, "window_area": {"value": 1.17, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 6, "window_area": {"value": 1.17, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 3, "window_area": {"value": 2.44, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 1.92, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 1, "window_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Mallow Road", "assessment_type": "RdSAP", "completion_date": "2018-08-06", "inspection_date": "2018-08-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 102, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-08-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 15, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.2, "quantity": "square metres"}, "party_wall_length": {"value": 14.76, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.45, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.81, "quantity": "metres"}, "total_floor_area": {"value": 31.88, "quantity": "square metres"}, "party_wall_length": {"value": 14.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.75, "quantity": "square metres"}, "party_wall_length": {"value": 3.84, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 10.75, "quantity": "square metres"}, "party_wall_length": {"value": 3.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 975, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 602, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 7, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.4, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2242, "impact_of_loft_insulation": -2156, "impact_of_solid_wall_insulation": -2602, "space_heating_existing_dwelling": 17687}, "energy_consumption_current": 317, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 133, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100031324275, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG9 1PA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-08-13 11:55:17.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10265}], "immersion_heating_type": "NA", "secondary_heating_type": 607, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5a, Lilac Grove", "address_line_2": "Beeston", "assessment_type": "RdSAP", "completion_date": "2018-08-13", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 123, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-08-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.2, "quantity": "square metres"}, "party_wall_length": {"value": 12.74, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.29, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.85, "quantity": "metres"}, "total_floor_area": {"value": 47.2, "quantity": "square metres"}, "party_wall_length": {"value": 12.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.29, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.11, "quantity": "metres"}, "total_floor_area": {"value": 28.62, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1037, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 77, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 622, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 371, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2294, "impact_of_loft_insulation": -250, "impact_of_solid_wall_insulation": -7775, "space_heating_existing_dwelling": 19219}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 117, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100040827470, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH12 4LT", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "POOLE", "built_form": 1, "created_at": "2018-11-26 14:45:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "371, Ringwood Road", "assessment_type": "RdSAP", "completion_date": "2018-11-26", "inspection_date": "2018-11-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-11-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 70.14, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 940, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 36, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 404, "currency": "GBP"}, "hot_water_cost_current": {"value": 288, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 32}, {"sequence": 2, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 38}, {"sequence": 3, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 44}, {"sequence": 5, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 6, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 7, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 334, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.1, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 49, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 201, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 94, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 258, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3401, "impact_of_loft_insulation": -570, "impact_of_cavity_insulation": -2030, "space_heating_existing_dwelling": 10779}, "energy_consumption_current": 514, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 88, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "F", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 91, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 72313498, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS18 5JL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 1, "created_at": "2018-10-11 11:44:04.000000", "door_count": 2, "glazed_area": 2, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "12, West End Rise", "address_line_2": "Horsforth", "assessment_type": "RdSAP", "completion_date": "2018-10-11", "inspection_date": "2018-10-01", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 119, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.85, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 35.85, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.69, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.59, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.52, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 6.62, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 972, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 740, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 72, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2851, "impact_of_loft_insulation": -553, "impact_of_cavity_insulation": -2809, "space_heating_existing_dwelling": 16480}, "energy_consumption_current": 277, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 158, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 26} +{"uprn": 100030491228, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LE16 9AX", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "MARKET HARBOROUGH", "built_form": 3, "created_at": "2018-12-04 13:35:38.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 4003}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "89, Nelson Street", "assessment_type": "RdSAP", "completion_date": "2018-12-04", "inspection_date": "2018-12-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 98, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-12-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.78, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 34.78, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 14.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1221, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 133, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 535, "currency": "GBP"}, "hot_water_cost_current": {"value": 206, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 492, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 6, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 7, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 8, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 9, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 165, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3398, "impact_of_solid_wall_insulation": -8332, "space_heating_existing_dwelling": 18754}, "energy_consumption_current": 441, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 115, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 64019893, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in 53% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF62 3AD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BARRY", "built_form": 1, "created_at": "2018-08-14 19:07:14", "door_count": 8, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 126, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "The Old Mill", "address_line_2": "Llancarfan", "assessment_type": "RdSAP", "completion_date": "2018-08-14", "inspection_date": "2018-07-30", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 339, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 10, "pvc_window_frames": "true", "registration_date": "2018-08-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.95, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 32.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 56.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 85.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.99, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 85.96, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 37.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 10, "heating_cost_current": {"value": 2165, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 16, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 201, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1226, "currency": "GBP"}, "hot_water_cost_current": {"value": 146, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 395, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 189, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 7, "typical_saving": {"value": 329, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "co2_emissions_potential": 8.3, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 136, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2944, "impact_of_solid_wall_insulation": -7412, "space_heating_existing_dwelling": 42536}, "energy_consumption_current": 203, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 100, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 38, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 100040312493, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX6 6AA", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "EXETER", "built_form": 2, "created_at": "2018-05-02 13:11:38.000000", "door_count": 3, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "1 Winslake Meadow", "address_line_2": "School Lane", "address_line_3": "Tedburn St. Mary", "assessment_type": "RdSAP", "completion_date": "2018-05-02", "inspection_date": "2018-05-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-05-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 63.63, "quantity": "square metres"}, "party_wall_length": {"value": 10.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 741, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 426, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 36}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 37}, {"sequence": 3, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 42}, {"sequence": 4, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 47}, {"sequence": 5, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 52}, {"sequence": 6, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 54}, {"sequence": 7, "typical_saving": {"value": 328, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 65}, {"sequence": 8, "typical_saving": {"value": 618, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 112, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.4, "energy_rating_potential": 112, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 51, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 60, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 264, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 166, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1869, "impact_of_loft_insulation": -457, "space_heating_existing_dwelling": 8288}, "energy_consumption_current": 504, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 38, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 85, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100100156435, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SA18 3AJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AMMANFORD", "built_form": 1, "created_at": "2018-08-07 14:11:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17576}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "73, Blaenau Road", "address_line_2": "Llandybie", "assessment_type": "RdSAP", "completion_date": "2018-08-07", "inspection_date": "2018-08-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-08-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.83, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 46.83, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 21.34, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.68, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 923, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 157, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 797, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 99, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 69}], "co2_emissions_potential": 3.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 78, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 130, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3515, "impact_of_loft_insulation": -3909, "impact_of_cavity_insulation": -2495, "space_heating_existing_dwelling": 18163}, "energy_consumption_current": 250, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 159, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100080905838, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 80% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WD3 5BH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "RICKMANSWORTH", "built_form": 2, "created_at": "2018-12-03 16:43:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15448}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "9, Bullsland Gardens", "address_line_2": "Chorleywood", "assessment_type": "RdSAP", "completion_date": "2018-12-03", "inspection_date": "2018-11-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-12-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.59, "quantity": "square metres"}, "party_wall_length": {"value": 6.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 478, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 352, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1837, "impact_of_loft_insulation": -554, "impact_of_cavity_insulation": -1336, "space_heating_existing_dwelling": 8270}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 83, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10012964623, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"system_build": "true", "high_exposure": "true"}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR14 0HF", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "CAMBORNE", "built_form": 4, "created_at": "2018-10-04 22:58:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 402, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.5, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "20, Tresawla Court", "address_line_2": "Tolvaddon", "assessment_type": "RdSAP", "completion_date": "2018-10-04", "inspection_date": "2018-10-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-10-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.75, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 29.4, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 574, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 76, "currency": "GBP"}, "indicative_cost": "2,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 51}, {"sequence": 6, "typical_saving": {"value": 347, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 62}], "co2_emissions_potential": 2.3, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 115, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 138, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2251, "space_heating_existing_dwelling": 6032}, "energy_consumption_current": 447, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 230, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 62, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 15043813, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NN2 7RE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORTHAMPTON", "built_form": 2, "created_at": "2018-12-06 20:24:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Newnham Road", "assessment_type": "RdSAP", "completion_date": "2018-12-06", "inspection_date": "2018-12-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 99, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-12-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.72, "quantity": "square metres"}, "party_wall_length": {"value": 5.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 49.72, "quantity": "square metres"}, "party_wall_length": {"value": 5.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.75, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 531, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 134, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 500, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 67, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2001, "space_heating_existing_dwelling": 9529}, "energy_consumption_current": 187, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 98, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10011955847, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "IP24 3AR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "THETFORD", "built_form": 2, "created_at": "2018-05-03 16:02:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 0, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10321}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "10, St. Marys Court", "assessment_type": "RdSAP", "completion_date": "2018-05-03", "inspection_date": "2018-05-03", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 5.68}, "total_floor_area": 79, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.2912, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 100, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 34.58, "quantity": "square metres"}, "party_wall_length": {"value": 6.88, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.25, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 41.11, "quantity": "square metres"}, "party_wall_length": {"value": 13.76, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.96, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.4, "quantity": "square metres"}, "party_wall_length": {"value": 3.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 1.89, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 317, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 133, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2781, "impact_of_solid_wall_insulation": -427, "space_heating_existing_dwelling": 4563}, "energy_consumption_current": 155, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 151, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100050573423, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO19 4RL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "YORK", "built_form": 4, "created_at": "2018-05-10 18:18:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "50, Naburn Lane", "address_line_2": "Fulford", "assessment_type": "RdSAP", "completion_date": "2018-05-10", "inspection_date": "2018-05-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-05-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, dual fuel (mineral and wood)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.09, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.2, "quantity": "square metres"}, "party_wall_length": {"value": 5.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 38.5, "quantity": "square metres"}, "party_wall_length": {"value": 11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 519, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 444, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 281, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.5, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2206, "impact_of_loft_insulation": -406, "impact_of_solid_wall_insulation": -825, "space_heating_existing_dwelling": 8516}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 107, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 41041599, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "L20 9JY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOOTLE", "built_form": 3, "created_at": "2018-03-13 17:22:55.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "120 Hawthorne Road", "assessment_type": "RdSAP", "completion_date": "2018-03-13", "inspection_date": "2018-03-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-03-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.76, "quantity": "metres"}, "total_floor_area": {"value": 68.34, "quantity": "square metres"}, "party_wall_length": {"value": 9.67, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 522, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 308, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 215, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 94, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1980, "impact_of_solid_wall_insulation": -4849, "space_heating_existing_dwelling": 9141}, "energy_consumption_current": 251, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 150, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 310059674, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 13% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "RG1 2NN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "READING", "built_form": 4, "created_at": "2018-10-08 10:07:10.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "26, Henry Street", "assessment_type": "RdSAP", "completion_date": "2018-10-08", "inspection_date": "2018-08-18", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.4, "quantity": "square metres"}, "party_wall_length": {"value": 14.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 27.5, "quantity": "square metres"}, "party_wall_length": {"value": 14.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.12, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.78, "quantity": "square metres"}, "party_wall_length": {"value": 3.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.69, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.64, "quantity": "metres"}, "total_floor_area": {"value": 7.78, "quantity": "square metres"}, "party_wall_length": {"value": 3.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 739, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 527, "currency": "GBP"}, "hot_water_cost_current": {"value": 187, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 48}, {"sequence": 4, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 49}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 6, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 8, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 52, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 56, "environmental_impact_rating": 89}, {"sequence": 3, "typical_saving": {"value": 234, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 60}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2903, "impact_of_loft_insulation": -2765, "impact_of_cavity_insulation": -896, "impact_of_solid_wall_insulation": -805, "space_heating_existing_dwelling": 10232}, "energy_consumption_current": 385, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 146, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100000310439, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 8% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "NE32 3SL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "JARROW", "built_form": 2, "created_at": "2018-09-22 15:57:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "32, Brixham Crescent", "assessment_type": "RdSAP", "completion_date": "2018-09-22", "inspection_date": "2018-09-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "registration_date": "2018-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.93, "quantity": "square metres"}, "party_wall_length": {"value": 7.95, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 43.73, "quantity": "square metres"}, "party_wall_length": {"value": 7.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 600, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 126, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 526, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 67}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2213, "impact_of_loft_insulation": -43, "space_heating_existing_dwelling": 9858}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 117, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 364945, "roofs": [{"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS1 5LZ", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-04-06 16:21:41.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 25", "address_line_2": "Harford House", "address_line_3": "20 Frogmore Street", "assessment_type": "RdSAP", "completion_date": "2018-04-06", "inspection_date": "2018-04-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.46, "quantity": "metres"}}, "total_floor_area": 22, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-04-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 170, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 22.14, "quantity": "square metres"}, "party_wall_length": {"value": 5.59, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 241, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 24, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 241, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 68, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 134, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 833, "space_heating_existing_dwelling": 1493}, "energy_consumption_current": 344, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 344, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 58, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100022200916, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "IG2 6QA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-05-12 11:29:08.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8441}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Cantley Gardens", "assessment_type": "RdSAP", "completion_date": "2018-05-12", "inspection_date": "2018-05-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.64, "quantity": "square metres"}, "party_wall_length": {"value": 13.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.57, "quantity": "metres"}, "total_floor_area": {"value": 36.96, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 470, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 288, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}, {"sequence": 6, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.6, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2066, "impact_of_solid_wall_insulation": -2538, "space_heating_existing_dwelling": 7028}, "energy_consumption_current": 219, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 42, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100022212036, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG3 9QE", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ILFORD", "built_form": 4, "created_at": "2018-05-14 13:42:48.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "8, Fenman Gardens", "assessment_type": "RdSAP", "completion_date": "2018-05-14", "inspection_date": "2018-05-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.71, "quantity": "metres"}}, "total_floor_area": 38, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-05-14", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.19, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 38.24, "quantity": "square metres"}, "party_wall_length": {"value": 11.89, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 195, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 107, "currency": "GBP"}, "hot_water_cost_current": {"value": 250, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 212, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 255, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 224, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1550, "space_heating_existing_dwelling": 1209}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 250, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100022680546, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW11 4EY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-03-16 18:01:12.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 45 Overstrand Mansions", "address_line_2": "Prince of Wales Drive", "assessment_type": "RdSAP", "completion_date": "2018-03-16", "inspection_date": "2018-03-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 4, "heat_loss_corridor": 1}, "total_floor_area": 145, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-03-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "total_floor_area": {"value": 145.08, "quantity": "square metres"}, "party_wall_length": {"value": 14.18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 35.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1397, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.9, "energy_rating_average": 60, "energy_rating_current": 49, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 938, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 193, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}], "co2_emissions_potential": 5.4, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2317, "impact_of_loft_insulation": -12054, "impact_of_solid_wall_insulation": -5675, "space_heating_existing_dwelling": 27011}, "energy_consumption_current": 310, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.04r01", "energy_consumption_potential": 211, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 55, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100060583245, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO20 6NW", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "STOCKBRIDGE", "built_form": 2, "created_at": "2018-11-20 18:43:21.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "5, Eldon Close", "address_line_2": "Kings Somborne", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-11-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 905, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.2, "energy_rating_average": 60, "energy_rating_current": 45, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 469, "currency": "GBP"}, "hot_water_cost_current": {"value": 175, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 34}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 39}, {"sequence": 4, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 40}, {"sequence": 5, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 40}, {"sequence": 6, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 47}, {"sequence": 7, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 52}, {"sequence": 8, "typical_saving": {"value": 330, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 86, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 323, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 210, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2041, "impact_of_cavity_insulation": -1802, "space_heating_existing_dwelling": 9559}, "energy_consumption_current": 681, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 254, "environmental_impact_current": 27, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 115, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W14 0PU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-07-31 17:09:54.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17644}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Top Floor Flat", "address_line_2": "18 Girdlers Road", "assessment_type": "RdSAP", "completion_date": "2018-07-31", "inspection_date": "2018-07-31", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 4, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.46, "quantity": "metres"}}, "total_floor_area": 62, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.74, "quantity": "metres"}, "total_floor_area": {"value": 62.34, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 643, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 61, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 474, "currency": "GBP"}, "hot_water_cost_current": {"value": 76, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 5, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.6, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1674, "impact_of_loft_insulation": -4657, "impact_of_solid_wall_insulation": -3401, "space_heating_existing_dwelling": 11887}, "energy_consumption_current": 322, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 235, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050814498, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S61 1SG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROTHERHAM", "built_form": 4, "created_at": "2018-05-16 16:37:53.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Avondale Road", "assessment_type": "RdSAP", "completion_date": "2018-05-16", "inspection_date": "2018-05-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.92, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.48, "quantity": "square metres"}, "party_wall_length": {"value": 18.6, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.9, "quantity": "metres"}, "total_floor_area": {"value": 33.48, "quantity": "square metres"}, "party_wall_length": {"value": 18.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 413, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 338, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 263, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.9, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1798, "impact_of_solid_wall_insulation": -1670, "space_heating_existing_dwelling": 6689}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 72, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 561861, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 8% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BS32 9AS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2018-01-24 17:15:25.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 2039}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "24, Saxon Way", "address_line_2": "Bradley Stoke", "assessment_type": "RdSAP", "completion_date": "2018-01-24", "inspection_date": "2018-01-24", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "false", "registration_date": "2018-01-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 51.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.5, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 684, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 141, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 569, "currency": "GBP"}, "hot_water_cost_current": {"value": 162, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 58, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.2, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 139, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2950, "impact_of_loft_insulation": -353, "space_heating_existing_dwelling": 11060}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 108, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100031670666, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 8% of fixed outlets", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DE13 8HY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BURTON-ON-TRENT", "built_form": 2, "created_at": "2018-10-23 17:27:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 3980}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "22, St. James Road", "address_line_2": "Barton under Needwood", "assessment_type": "RdSAP", "completion_date": "2018-10-23", "inspection_date": "2018-10-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 80, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.13, "quantity": "square metres"}, "party_wall_length": {"value": 6.31, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.03, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 40.13, "quantity": "square metres"}, "party_wall_length": {"value": 6.31, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.03, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 8, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 517, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 489, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2808, "space_heating_existing_dwelling": 7887}, "energy_consumption_current": 238, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 126, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10033238943, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW11 3HE", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-17 21:17:00.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 5", "address_line_2": "2, Winders Road", "assessment_type": "RdSAP", "completion_date": "2018-09-17", "inspection_date": "2018-09-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 1.08}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-09-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.4516, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 200, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 58.87, "quantity": "square metres"}, "party_wall_length": {"value": 22.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 57, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 66, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 152, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1913, "space_heating_existing_dwelling": 526}, "energy_consumption_current": 158, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 147, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "B", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 44088340, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ME8 6QG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "GILLINGHAM", "built_form": 2, "created_at": "2018-09-22 20:05:28.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Littlebourne Avenue", "assessment_type": "RdSAP", "completion_date": "2018-09-22", "inspection_date": "2018-09-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.04, "quantity": "square metres"}, "party_wall_length": {"value": 4.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 35.04, "quantity": "square metres"}, "party_wall_length": {"value": 4.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 421, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 371, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2275, "impact_of_loft_insulation": -476, "space_heating_existing_dwelling": 7005}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 80, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 12076459, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 85% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W13 8DE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-04-26 17:40:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "44, Bellevue Road", "assessment_type": "RdSAP", "completion_date": "2018-04-26", "inspection_date": "2018-04-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 135, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 19.63, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "E"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.59, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 48.59, "quantity": "square metres"}, "party_wall_length": {"value": 16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 1.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1133, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 776, "currency": "GBP"}, "hot_water_cost_current": {"value": 93, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 6, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "co2_emissions_potential": 3.5, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 93, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2069, "impact_of_loft_insulation": -2241, "impact_of_cavity_insulation": -457, "impact_of_solid_wall_insulation": -1842, "space_heating_existing_dwelling": 20364}, "energy_consumption_current": 266, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 80, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 145, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10023870701, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BH8 9AW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOURNEMOUTH", "built_form": 2, "created_at": "2018-11-20 12:40:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15200}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "393, Holdenhurst Road", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-11-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 6.7}, "total_floor_area": 39, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.879, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 350, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 38.55, "quantity": "square metres"}, "party_wall_length": {"value": 6.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.23, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 157, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.9, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 161, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1526, "space_heating_existing_dwelling": 948}, "energy_consumption_current": 140, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 127, "environmental_impact_current": 84, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 24, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 200004789555, "roofs": [{"description": {"value": "Pitched, insulated at rafters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RH12 1HE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HORSHAM", "built_form": 3, "created_at": "2018-11-28 10:25:15.000000", "door_count": 2, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10200}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "24, Causeway", "assessment_type": "RdSAP", "completion_date": "2018-11-28", "inspection_date": "2018-11-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-11-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.08, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.04, "quantity": "square metres"}, "party_wall_length": {"value": 3.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.08, "quantity": "metres"}, "total_floor_area": {"value": 23.89, "quantity": "square metres"}, "party_wall_length": {"value": 3.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "rafter_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.2, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 634, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 341, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 192, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 10, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 7, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2753, "impact_of_loft_insulation": -768, "impact_of_solid_wall_insulation": -4346, "space_heating_existing_dwelling": 11658}, "energy_consumption_current": 371, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.0.x", "energy_consumption_potential": 82, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 66, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100040274989, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ6 9EN", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "DARTMOUTH", "built_form": 1, "created_at": "2018-10-11 18:37:28.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230003, "number_of_heaters": 3, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "14b, Fairview Road", "assessment_type": "RdSAP", "completion_date": "2018-10-11", "inspection_date": "2018-10-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 2, "heated_room_count": 3, "registration_date": "2018-10-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71, "quantity": "square metres"}, "party_wall_length": {"value": 8.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 675, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": "Controls for high heat retention storage heaters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 260, "currency": "GBP"}, "hot_water_cost_current": {"value": 357, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 355, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 279, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2443, "impact_of_solid_wall_insulation": -4041, "space_heating_existing_dwelling": 7588}, "energy_consumption_current": 448, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 221, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 76, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100120841511, "roofs": [{"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 11% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "OX1 2JG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "OXFORD", "built_form": 3, "created_at": "2018-05-11 18:50:47", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 2}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10204}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "7, Walton Crescent", "assessment_type": "RdSAP", "completion_date": "2018-05-11", "inspection_date": "2018-05-11", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 189, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 7, "registration_date": "2018-05-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 34.56, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 54.72, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 1, "wall_thickness_measured": "N", "wall_insulation_thickness": "50mm"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.27, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.41, "quantity": "square metres"}, "party_wall_length": {"value": 7.04, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.68, "quantity": "metres"}, "total_floor_area": {"value": 34.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.91, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 35.46, "quantity": "square metres"}, "party_wall_length": {"value": 7.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 340, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 12.49, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "J", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.51, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.31, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 12.42, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.28, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 12.46, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 908, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 180, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 820, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3155", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 3.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 96, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2998, "impact_of_solid_wall_insulation": -2201, "space_heating_existing_dwelling": 16641}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 35, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100012597084, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CW11 1EF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SANDBACH", "built_form": 1, "created_at": "2018-10-05 20:54:29.000000", "door_count": 1, "glazed_area": 4, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17033}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "sap_windows": [{"orientation": 1, "window_area": {"value": 5.46, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 3.06, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 5, "window_area": {"value": 2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 5, "window_area": {"value": 3.1, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 3, "window_area": {"value": 0.45, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 4.6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 5, "window_area": {"value": 2.2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 3, "window_area": {"value": 0.45, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 8.2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 7, "window_area": {"value": 2.66, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 7, "window_area": {"value": 2, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 1, "window_area": {"value": 9.9, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 1, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 5, "window_area": {"value": 2.64, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 2, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 7, "window_area": {"value": 1.6, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}, {"orientation": 7, "window_area": {"value": 0.18, "quantity": "square metres"}, "window_type": 1, "glazing_type": 2, "window_location": 0, "window_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "1, Bramall Close", "assessment_type": "RdSAP", "completion_date": "2018-10-05", "inspection_date": "2018-10-05", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 181, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "registration_date": "2018-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.42, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 62.84, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 23.05, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.42, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.75, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.42, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.64, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1068, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1012, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 74}], "co2_emissions_potential": 4.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 92, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2897, "impact_of_loft_insulation": -684, "space_heating_existing_dwelling": 17090}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 132, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "C", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 25} +{"uprn": 200002713019, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 56% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN16 4AB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LITTLEHAMPTON", "built_form": 3, "created_at": "2018-10-15 20:06:11.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15100}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "3, Honey Lane", "address_line_2": "Angmering", "assessment_type": "RdSAP", "completion_date": "2018-10-15", "inspection_date": "2018-10-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 53, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.57, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 26.57, "quantity": "square metres"}, "party_wall_length": {"value": 6.78, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 56, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 444, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 285, "currency": "GBP"}, "hot_water_cost_current": {"value": 118, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 137, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 339, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.4, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2539, "impact_of_loft_insulation": -233, "impact_of_solid_wall_insulation": -2971, "space_heating_existing_dwelling": 7000}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 39, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100070975605, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 85% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B93 8LR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOLIHULL", "built_form": 1, "created_at": "2018-04-12 20:39:06", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15514}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, Arden Road", "address_line_2": "Dorridge", "assessment_type": "RdSAP", "completion_date": "2018-04-12", "inspection_date": "2018-04-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 135, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2018-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.84, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 59.34, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 31.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.45, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 85, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 770, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 718, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2307, "space_heating_existing_dwelling": 13685}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 123, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 17} +{"uprn": 100090147116, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB21 4NP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 1, "created_at": "2018-04-10 10:34:13", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "15, Joiners Road", "address_line_2": "Linton", "assessment_type": "RdSAP", "completion_date": "2018-04-10", "inspection_date": "2018-04-06", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 245, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 9, "pvc_window_frames": "true", "registration_date": "2018-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 258, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 5.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.98, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 35.37, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.64, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 75.67, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 26.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 75.67, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 352, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.11, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 9, "heating_cost_current": {"value": 2075, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1358, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 716, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "co2_emissions_potential": 6.1, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 111, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 151, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3027, "impact_of_loft_insulation": -3006, "impact_of_solid_wall_insulation": -14759, "space_heating_existing_dwelling": 38671}, "energy_consumption_current": 263, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 154, "environmental_impact_current": 51, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 100060730055, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [6], "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SO16 6RN", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "SOUTHAMPTON", "built_form": 3, "created_at": "2018-02-28 08:32:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "14, Seagarth Close", "assessment_type": "RdSAP", "completion_date": "2018-02-28", "inspection_date": "2018-02-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 40, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 39.85, "quantity": "square metres"}, "party_wall_length": {"value": 5.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 675, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 38, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 218, "currency": "GBP"}, "hot_water_cost_current": {"value": 253, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 199, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 370, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 56}, {"sequence": 4, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 58}], "co2_emissions_potential": 2.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 104, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 450, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 403, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 123, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1567, "impact_of_cavity_insulation": -1237, "space_heating_existing_dwelling": 4188}, "energy_consumption_current": 467, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 342, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "F", "environmental_impact_potential": 58, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 79, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 42019495, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH42 1PA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "BIRKENHEAD", "built_form": 4, "created_at": "2018-02-07 16:53:56.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "37, Buxton Road", "assessment_type": "RdSAP", "completion_date": "2018-02-07", "inspection_date": "2018-02-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 101, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-02-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 345, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.99, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.1, "quantity": "square metres"}, "party_wall_length": {"value": 15.38, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.82, "quantity": "metres"}, "total_floor_area": {"value": 42.91, "quantity": "square metres"}, "party_wall_length": {"value": 15.38, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 345, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.82, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.83, "quantity": "square metres"}, "party_wall_length": {"value": 2.81, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.27, "quantity": "metres"}, "total_floor_area": {"value": 6.83, "quantity": "square metres"}, "party_wall_length": {"value": 2.81, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 668, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 173, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2472, "impact_of_solid_wall_insulation": -3453, "space_heating_existing_dwelling": 11057}, "energy_consumption_current": 218, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 90, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100090438075, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO4 0DU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 4, "created_at": "2018-07-22 20:54:51.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "11, Ayloffe Road", "assessment_type": "RdSAP", "completion_date": "2018-07-22", "inspection_date": "2018-07-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-07-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.45, "quantity": "square metres"}, "party_wall_length": {"value": 13.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.8, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.44, "quantity": "square metres"}, "party_wall_length": {"value": 2.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.2, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 301, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 278, "currency": "GBP"}, "hot_water_cost_current": {"value": 82, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.4, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1833, "space_heating_existing_dwelling": 4270}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 50, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100030980011, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN18 8BH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CORBY", "built_form": 2, "created_at": "2018-08-07 11:03:35.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Counts Farm Road", "assessment_type": "RdSAP", "completion_date": "2018-08-07", "inspection_date": "2018-05-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-08-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 45.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 490, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 463, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a31,000 - \u00a31,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.7, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2658, "impact_of_loft_insulation": -227, "space_heating_existing_dwelling": 7885}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 103, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100021076809, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "E9 5TJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-14 19:18:31.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "5, Edmeston Close", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.01, "quantity": "square metres"}, "party_wall_length": {"value": 13.5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 33.01, "quantity": "square metres"}, "party_wall_length": {"value": 13.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 338, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 103, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 308, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.6, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 49, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1708, "impact_of_loft_insulation": -325, "space_heating_existing_dwelling": 5047}, "energy_consumption_current": 177, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 49, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 34056615, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some double glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": "Low energy lighting in 11% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "W14 0TJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-03-02 14:21:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17501}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Basement flat", "language_code": 1, "property_type": 2, "address_line_1": "83a, Edith Road", "assessment_type": "RdSAP", "completion_date": "2018-03-02", "inspection_date": "2018-03-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 0}, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79, "quantity": "square metres"}, "party_wall_length": {"value": 25.34, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 11, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 402, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 251, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 64, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 85, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1877, "impact_of_solid_wall_insulation": -2049, "space_heating_existing_dwelling": 6517}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "3.04r01", "energy_consumption_potential": 106, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 25013585, "roofs": [{"description": "Pitched, 75 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK8 8HN", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "MILTON KEYNES", "built_form": 2, "created_at": "2018-08-09 16:36:05.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "72, Downland", "address_line_2": "Two Mile Ash", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 41, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.8, "quantity": "square metres"}, "party_wall_length": {"value": 8.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 339, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": "Automatic charge control", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 211, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.1, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 144, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 80, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 143, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1577, "impact_of_loft_insulation": -887, "space_heating_existing_dwelling": 3527}, "energy_consumption_current": 399, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 307, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 10003583174, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 30% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG10 5QX", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-10-18 13:00:33.000000", "door_count": 0, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "92, Springfield Mill", "address_line_2": "Sandiacre", "assessment_type": "RdSAP", "completion_date": "2018-10-18", "inspection_date": "2018-10-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-10-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.16, "quantity": "metres"}, "total_floor_area": {"value": 69.35, "quantity": "square metres"}, "party_wall_length": {"value": 15.11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.82, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 570, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 179, "currency": "GBP"}, "hot_water_cost_current": {"value": 319, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 368, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 334, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 162, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1927, "impact_of_solid_wall_insulation": -1595, "space_heating_existing_dwelling": 3443}, "energy_consumption_current": 262, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 190, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 24006912, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "BS23 4JA", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "WESTON-SUPER-MARE", "built_form": 3, "created_at": "2018-08-18 22:19:44.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 401, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "2 Devonshire Court", "address_line_2": "Moorland Road", "assessment_type": "RdSAP", "completion_date": "2018-08-18", "inspection_date": "2018-08-17", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 69, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 572, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 114, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 367, "currency": "GBP"}, "hot_water_cost_current": {"value": 221, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 55}], "co2_emissions_potential": 3.5, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 252, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 171, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2706, "space_heating_existing_dwelling": 6373}, "energy_consumption_current": 430, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 296, "environmental_impact_current": 40, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 55, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 10023292699, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B5 7QP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2018-12-03 21:33:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Apartment 7 Priory Court", "address_line_2": "243, Pershore Road", "assessment_type": "RdSAP", "completion_date": "2018-12-03", "inspection_date": "2018-11-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 8, "quantity": "metres"}}, "total_floor_area": 44, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-12-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.2, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.6, "quantity": "square metres"}, "party_wall_length": {"value": 0.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 272, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 249, "currency": "GBP"}, "hot_water_cost_current": {"value": 85, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1982, "space_heating_existing_dwelling": 3599}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 183, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100032143458, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NN15 6NR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KETTERING", "built_form": 3, "created_at": "2018-04-14 16:12:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17955}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 Chester Court", "address_line_2": "Highfield Road", "assessment_type": "RdSAP", "completion_date": "2018-04-14", "inspection_date": "2018-04-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 3}, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-04-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.99, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 270, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.6, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 314, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 267, "currency": "GBP"}, "hot_water_cost_current": {"value": 63, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1391, "space_heating_existing_dwelling": 4514}, "energy_consumption_current": 196, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 166, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 42014393, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CH43 7PQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PRENTON", "built_form": 3, "created_at": "2018-09-28 10:36:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "94, Boundary Road", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-05-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 36, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 524, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 441, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2026, "space_heating_existing_dwelling": 6519}, "energy_consumption_current": 242, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 109, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050682431, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S63 8AG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROTHERHAM", "built_form": 2, "created_at": "2018-06-13 19:59:25", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "2 , Thurnscoe Road", "address_line_2": "Bolton-upon-Dearne", "assessment_type": "RdSAP", "completion_date": "2018-06-13", "inspection_date": "2018-06-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-06-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 37.9, "quantity": "square metres"}, "party_wall_length": {"value": 6.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.9, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 473, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 436, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.3, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2228, "space_heating_existing_dwelling": 7506}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 105, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 36% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH14 9HY", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}, "post_town": "POOLE", "built_form": 2, "created_at": "2018-01-11 12:41:20.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 950, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2402, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 31, Downy Court", "address_line_2": "154-166, Bournemouth Road", "assessment_type": "RdSAP", "completion_date": "2018-01-11", "inspection_date": "2018-01-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 3, "heat_loss_corridor": 1}, "total_floor_area": 37, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-01-11", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.55, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 310, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 37.47, "quantity": "square metres"}, "party_wall_length": {"value": 6.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 36, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 220, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Automatic charge control", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 192, "currency": "GBP"}, "hot_water_cost_current": {"value": 121, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.7, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 33, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 117, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "hot_water_cost_potential": {"value": 121, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2140, "space_heating_existing_dwelling": 1904}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 258, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "C", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 2465190258, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 70% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE1 7HB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2018-07-08 08:59:31.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15741}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Lancaster Place", "assessment_type": "RdSAP", "completion_date": "2018-07-08", "inspection_date": "2018-07-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-07-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.91, "quantity": "square metres"}, "party_wall_length": {"value": 4.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 25.58, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 45.91, "quantity": "square metres"}, "party_wall_length": {"value": 4.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 874, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 82, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 441, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2197, "impact_of_solid_wall_insulation": -6129, "space_heating_existing_dwelling": 16075}, "energy_consumption_current": 312, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r03", "energy_consumption_potential": 93, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100022296865, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 53% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SW14 7PZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-06-20 15:33:58.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15106}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, Palmerston Road", "assessment_type": "RdSAP", "completion_date": "2018-06-20", "inspection_date": "2018-06-20", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 144, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-06-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 28.2, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.59, "quantity": "square metres"}, "party_wall_length": {"value": 17.28, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.57, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.72, "quantity": "metres"}, "total_floor_area": {"value": 50.59, "quantity": "square metres"}, "party_wall_length": {"value": 17.28, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.42, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.1, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.45, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 53, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 850, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.2, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 117, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 666, "currency": "GBP"}, "hot_water_cost_current": {"value": 141, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 50, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 7, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2988, "impact_of_loft_insulation": -1750, "impact_of_solid_wall_insulation": -1835, "space_heating_existing_dwelling": 15813}, "energy_consumption_current": 204, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 40, "calculation_software_version": "2.0.x", "energy_consumption_potential": 110, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200002647975, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL65 3AN", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "HOLYHEAD", "built_form": 1, "created_at": "2018-11-08 12:48:34", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8872}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "4, Glantraeth Estate", "address_line_2": "Valley", "assessment_type": "RdSAP", "completion_date": "2018-11-08", "inspection_date": "2018-11-07", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 1, "percent_roof_area": 40}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 86.9, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 38.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 516, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 458, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 83}, {"sequence": 3, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3449, "space_heating_existing_dwelling": 8248}, "energy_consumption_current": 119, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 51, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100040071352, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR15 3DS", "hot_water": {"description": "From main system", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}, "post_town": "REDRUTH", "built_form": 2, "created_at": "2018-02-11 23:23:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 3, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 3, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "21, Carn Brea Lane", "address_line_2": "Pool", "assessment_type": "RdSAP", "completion_date": "2018-02-11", "inspection_date": "2018-02-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 700, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.02, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.67, "quantity": "square metres"}, "party_wall_length": {"value": 5.68, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.13, "quantity": "metres"}, "total_floor_area": {"value": 20.67, "quantity": "square metres"}, "party_wall_length": {"value": 5.68, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.54, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.33, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 925, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 25, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 522, "currency": "GBP"}, "hot_water_cost_current": {"value": 225, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 40, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 96, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 51, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 86}, {"sequence": 6, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 95, "environmental_impact_rating": 112}], "co2_emissions_potential": -1.2, "energy_rating_potential": 95, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 131, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1727, "impact_of_solid_wall_insulation": -2348, "space_heating_existing_dwelling": 7222}, "energy_consumption_current": 251, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": -179, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "F", "environmental_impact_potential": 112, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 217114317, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SW7 5NL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 6, "created_at": "2018-04-24 14:50:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "Flat 2", "address_line_2": "31 Elvaston Place", "assessment_type": "RdSAP", "completion_date": "2018-04-24", "inspection_date": "2018-04-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 550, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.31, "quantity": "square metres"}, "party_wall_length": {"value": 22.59, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.66, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3.75, "quantity": "metres"}, "total_floor_area": {"value": 39.4, "quantity": "square metres"}, "party_wall_length": {"value": 17.43, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 488, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 115, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 280, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2358, "impact_of_solid_wall_insulation": -3414, "space_heating_existing_dwelling": 8406}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.05r02", "energy_consumption_potential": 123, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031587379, "roofs": [{"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 84% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG7 1JU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2018-11-19 16:30:05.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "87, Rolleston Drive", "assessment_type": "RdSAP", "completion_date": "2018-11-19", "inspection_date": "2018-11-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 141, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-11-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "sap_room_in_roof": {"floor_area": 32.6, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.57, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.7, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.16, "quantity": "metres"}, "total_floor_area": {"value": 42.4, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 84, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1345, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.7, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 97, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 702, "currency": "GBP"}, "hot_water_cost_current": {"value": 113, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 273, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.1, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 97, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2313, "impact_of_loft_insulation": -746, "impact_of_solid_wall_insulation": -4875, "space_heating_existing_dwelling": 24549}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 124, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 19, "current_energy_efficiency_band": "E", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 10067625005, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Some secondary glazing", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO39 0JD", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "TOTLAND BAY", "built_form": 2, "created_at": "2018-10-24 21:01:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "1 Headon Cottages", "address_line_2": "Alum Bay", "assessment_type": "RdSAP", "completion_date": "2018-10-24", "inspection_date": "2018-10-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 58, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 22, "wall_dry_lined": "Y", "wall_thickness": 500, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.5, "quantity": "square metres"}, "party_wall_length": {"value": 13.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 926, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 320, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 28}, {"sequence": 2, "typical_saving": {"value": 214, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 37}, {"sequence": 3, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 44}, {"sequence": 4, "typical_saving": {"value": 128, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 365, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 74}, {"sequence": 8, "typical_saving": {"value": 635, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 119, "environmental_impact_rating": 99}], "co2_emissions_potential": -0.5, "energy_rating_potential": 119, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 280, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 188, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 75}], "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1767, "impact_of_loft_insulation": -672, "impact_of_solid_wall_insulation": -2285, "space_heating_existing_dwelling": 9787}, "energy_consumption_current": 631, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "3.08r07", "energy_consumption_potential": -53, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "E", "environmental_impact_potential": 99, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 107, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100031766010, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST16 1LZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 3, "created_at": "2018-12-19 16:21:31.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16454}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Edwards Drive", "assessment_type": "RdSAP", "completion_date": "2018-12-19", "inspection_date": "2018-12-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-12-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.32, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 28.32, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 359, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 363, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2433, "impact_of_loft_insulation": -186, "space_heating_existing_dwelling": 5582}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 101, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 18, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 18} +{"uprn": 10014107557, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO20 8AF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "CHICHESTER", "built_form": 4, "created_at": "2018-12-20 15:18:42.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "7, The Paddock", "address_line_2": "Bracklesham Bay", "assessment_type": "RdSAP", "completion_date": "2018-12-20", "inspection_date": "2018-12-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.62, "quantity": "metres"}}, "total_floor_area": 51, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-12-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 6.55, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 50.65, "quantity": "square metres"}, "party_wall_length": {"value": 11.41, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 227, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 202, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.2, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 90, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2063, "impact_of_loft_insulation": -607, "space_heating_existing_dwelling": 2544}, "energy_consumption_current": 153, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 132, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010037156, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CW12 4EG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CONGLETON", "built_form": 4, "created_at": "2018-05-16 08:28:57.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8408}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "75, Astbury Street", "assessment_type": "RdSAP", "completion_date": "2018-05-16", "inspection_date": "2018-05-14", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.78, "quantity": "square metres"}, "party_wall_length": {"value": 13.14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 23.78, "quantity": "square metres"}, "party_wall_length": {"value": 13.14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.95, "quantity": "square metres"}, "party_wall_length": {"value": 2.15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 454, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 305, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 7, "typical_saving": {"value": 278, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 91}], "co2_emissions_potential": 0.7, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2466, "impact_of_loft_insulation": -152, "impact_of_cavity_insulation": -589, "impact_of_solid_wall_insulation": -767, "space_heating_existing_dwelling": 6697}, "energy_consumption_current": 268, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 67, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 91, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": null, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "KT24 5DR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEATHERHEAD", "built_form": 1, "created_at": "2018-05-18 13:24:02.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Moles Way", "address_line_2": "Norrels Drive", "address_line_3": "East Horsley", "assessment_type": "RdSAP", "completion_date": "2018-05-18", "inspection_date": "2018-05-16", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 155, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-05-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.09, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 21.59, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.29, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 15.95, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 10.77, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.22, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 16.71, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 5.79, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1110, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 172, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 780, "currency": "GBP"}, "hot_water_cost_current": {"value": 149, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 169, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": 75, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 69}, {"sequence": 6, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2995, "space_heating_existing_dwelling": 20940}, "energy_consumption_current": 248, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 124, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100071709, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "RM10 9EX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAGENHAM", "built_form": 3, "created_at": "2018-07-12 17:57:41.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "25, Oval Road North", "assessment_type": "RdSAP", "completion_date": "2018-07-12", "inspection_date": "2018-06-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 30.36, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 609, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 96, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 506, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 74, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 5, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 74}], "co2_emissions_potential": 1.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1958, "impact_of_loft_insulation": -2820, "impact_of_cavity_insulation": -1792, "space_heating_existing_dwelling": 11100}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 143, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100120984050, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN8 1ER", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "MARLBOROUGH", "built_form": 2, "created_at": "2018-07-04 23:31:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "88, Rabley Wood View", "assessment_type": "RdSAP", "completion_date": "2018-07-04", "inspection_date": "2018-06-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_u_value": 1.43, "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.64, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 15.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 29.64, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1150, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.4, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 483, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 374, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 51}, {"sequence": 5, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 57}, {"sequence": 6, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.4, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 319, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 96}, {"sequence": 3, "typical_saving": {"value": 217, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 76}], "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1821, "impact_of_loft_insulation": -243, "impact_of_cavity_insulation": -4001, "space_heating_existing_dwelling": 12175}, "energy_consumption_current": 739, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 244, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 125, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100021949820, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SE6 2QG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-10-29 16:08:15.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "82, Daneby Road", "assessment_type": "RdSAP", "completion_date": "2018-10-29", "inspection_date": "2018-10-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 112, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, smokeless fuel", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.66, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.66, "quantity": "metres"}, "total_floor_area": {"value": 56.69, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 835, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.8, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 161, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 471, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2950, "impact_of_solid_wall_insulation": -5862, "space_heating_existing_dwelling": 12876}, "energy_consumption_current": 250, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 79, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100090450576, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 78% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CO5 8BZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COLCHESTER", "built_form": 1, "created_at": "2018-09-06 17:30:49.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "30, Estuary Park Road", "address_line_2": "West Mersea", "assessment_type": "RdSAP", "completion_date": "2018-09-06", "inspection_date": "2018-09-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 140, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-09-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 35.99, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 59.63, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 200, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 21.02, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.66, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 716, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 663, "currency": "GBP"}, "hot_water_cost_current": {"value": 145, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 96, "environmental_impact_rating": 90}], "co2_emissions_potential": 1.0, "energy_rating_potential": 96, "lighting_cost_potential": {"value": 106, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3154, "space_heating_existing_dwelling": 13780}, "energy_consumption_current": 182, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 37, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 27, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 21} +{"uprn": null, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E10 5EQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 6, "created_at": "2018-09-20 18:57:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8360}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "93a Vicarage Road", "assessment_type": "RdSAP", "completion_date": "2018-09-20", "inspection_date": "2018-09-20", "extensions_count": 0, "measurement_type": 2, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 29, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.596, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.245, "quantity": "square metres"}, "party_wall_length": {"value": 24.398, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.488, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 370, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 256, "currency": "GBP"}, "hot_water_cost_current": {"value": 74, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 13, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3900", "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.2, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 29, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}}], "hot_water_cost_potential": {"value": 52, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1407, "space_heating_existing_dwelling": 4724}, "energy_consumption_current": 388, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 244, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100020377032, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BR3 4AJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BECKENHAM", "built_form": 2, "created_at": "2018-07-12 13:16:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15701}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, Elmerside Road", "assessment_type": "RdSAP", "completion_date": "2018-07-12", "inspection_date": "2018-07-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.23, "quantity": "square metres"}, "party_wall_length": {"value": 5.03, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.18, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 41.01, "quantity": "square metres"}, "party_wall_length": {"value": 5.03, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 706, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 567, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 62}}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2137, "impact_of_loft_insulation": -3109, "impact_of_cavity_insulation": -2653, "space_heating_existing_dwelling": 13504}, "energy_consumption_current": 276, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 144, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100090344573, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM14 4HU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRENTWOOD", "built_form": 2, "created_at": "2018-09-12 19:20:09.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17795}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "3, Leasway", "address_line_2": "Rose Valley", "assessment_type": "RdSAP", "completion_date": "2018-09-12", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 52, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.36, "quantity": "square metres"}, "party_wall_length": {"value": 9.82, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 456, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 271, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1859, "impact_of_solid_wall_insulation": -2256, "space_heating_existing_dwelling": 5756}, "energy_consumption_current": 244, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 154, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200000525423, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "CM13 2TH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "BRENTWOOD", "built_form": 2, "created_at": "2018-09-13 21:56:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 115, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, Brocksparkwood", "assessment_type": "RdSAP", "completion_date": "2018-09-13", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 76, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.13, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 44.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.13, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 457, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 6, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 93}, {"sequence": 2, "typical_saving": {"value": 130, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2776, "space_heating_existing_dwelling": 5787}, "energy_consumption_current": 245, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 59, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100040806163, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BH12 4PN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 3, "created_at": "2018-07-22 08:24:34", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17761}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "19, Farwell Road", "assessment_type": "RdSAP", "completion_date": "2018-07-22", "inspection_date": "2018-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"pv_arrays": [{"pitch": 3, "peak_power": 1.44, "orientation": 6, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 305, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.49, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.27, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 41.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.49, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.27, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 421, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 392, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2151, "space_heating_existing_dwelling": 7018}, "energy_consumption_current": 126, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 97, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100061065034, "roofs": [{"description": {"value": "Pitched, 25 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 14% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "ME13 8HD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FAVERSHAM", "built_form": 4, "created_at": "2018-07-18 08:54:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "78, Cyprus Road", "assessment_type": "RdSAP", "completion_date": "2018-07-18", "inspection_date": "2018-07-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.7, "quantity": "square metres"}, "party_wall_length": {"value": 19.64, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 62.41, "quantity": "square metres"}, "party_wall_length": {"value": 20.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 579, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 137, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 457, "currency": "GBP"}, "hot_water_cost_current": {"value": 125, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2725, "impact_of_loft_insulation": -2229, "space_heating_existing_dwelling": 10629}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 64, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 452037107, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 6% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "TF1 1PE", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "TELFORD", "built_form": 2, "created_at": "2018-04-07 08:15:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 119, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "71, Regent Street", "address_line_2": "Wellington", "assessment_type": "RdSAP", "completion_date": "2018-04-07", "inspection_date": "2018-04-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 174, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 24.72, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 74.45, "quantity": "square metres"}, "party_wall_length": {"value": 10.3, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 24.74, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 74.45, "quantity": "square metres"}, "party_wall_length": {"value": 10.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 24.74, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 6, "solar_water_heating": "N", "habitable_room_count": 85, "heating_cost_current": {"value": 2451, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 14, "energy_rating_average": 60, "energy_rating_current": 29, "lighting_cost_current": {"value": 174, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1174, "currency": "GBP"}, "hot_water_cost_current": {"value": 583, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 38, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 384, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 71, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 37, "environmental_impact_rating": 35}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 36}, {"sequence": 4, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a375", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 37}, {"sequence": 5, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 39}, {"sequence": 6, "typical_saving": {"value": 1086, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 56}, {"sequence": 7, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 58}, {"sequence": 8, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 9, "typical_saving": {"value": 287, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 65}], "co2_emissions_potential": 5.6, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 757, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 429, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 54, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 1134, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 55}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3618, "impact_of_loft_insulation": -3808, "impact_of_solid_wall_insulation": -5985, "space_heating_existing_dwelling": 33115}, "energy_consumption_current": 461, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 38, "sap_deselected_improvements": ["C"], "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 180, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 80, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100100197648, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL18 3AL", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "RHYL", "built_form": 4, "created_at": "2018-05-24 22:20:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16406}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 7", "address_line_2": "22 East Parade", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 51, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 197, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 144, "currency": "GBP"}, "hot_water_cost_current": {"value": 253, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 257, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 4869, "impact_of_solid_wall_insulation": -1131, "space_heating_existing_dwelling": 1774}, "energy_consumption_current": 225, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 196, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 2465062154, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 70% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LE4 0DB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEICESTER", "built_form": 2, "created_at": "2018-05-23 18:07:05.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17660}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "248, Abbey Lane", "assessment_type": "RdSAP", "completion_date": "2018-05-23", "inspection_date": "2018-05-23", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.55, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.35, "quantity": "square metres"}, "party_wall_length": {"value": 7.21, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.72, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.52, "quantity": "metres"}, "total_floor_area": {"value": 36.35, "quantity": "square metres"}, "party_wall_length": {"value": 7.21, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.21, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 70, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 868, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 505, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a31,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.7, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1890, "impact_of_loft_insulation": -358, "impact_of_solid_wall_insulation": -4846, "space_heating_existing_dwelling": 12455}, "energy_consumption_current": 355, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 125, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100070118789, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 32% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B46 1RD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 2, "created_at": "2018-05-29 18:55:26.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 15, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10432}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "58, Coleshill Road", "address_line_2": "Water Orton", "assessment_type": "RdSAP", "completion_date": "2018-05-29", "inspection_date": "2018-05-29", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 129, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-05-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, smokeless fuel", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.4473, "quantity": "square metres"}, "party_wall_length": {"value": 7.39, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.228, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 45.8919, "quantity": "square metres"}, "party_wall_length": {"value": 7.39, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.3072, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.4784, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 32, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 958, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.3, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 130, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 786, "currency": "GBP"}, "hot_water_cost_current": {"value": 110, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a395", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 59}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 61}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 68}], "co2_emissions_potential": 4.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 77, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2302, "impact_of_cavity_insulation": -2252, "space_heating_existing_dwelling": 14699}, "energy_consumption_current": 235, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 138, "environmental_impact_current": 50, "fixed_lighting_outlets_count": 28, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100050849003, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, insulated", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S65 2AX", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ROTHERHAM", "built_form": 4, "created_at": "2018-05-24 11:11:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "78, Lister Street", "assessment_type": "RdSAP", "completion_date": "2018-05-24", "inspection_date": "2018-05-22", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 34.68, "quantity": "square metres"}, "party_wall_length": {"value": 8.75, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 45.04, "quantity": "square metres"}, "party_wall_length": {"value": 20.75, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "150mm"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 7, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.77, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.83, "quantity": "square metres"}, "party_wall_length": {"value": 3.25, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.35, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1368, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 10, "energy_rating_average": 60, "energy_rating_current": 33, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 671, "currency": "GBP"}, "hot_water_cost_current": {"value": 492, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 35, "environmental_impact_rating": 23}, {"sequence": 2, "typical_saving": {"value": 495, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 38}, {"sequence": 3, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 40}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 41}, {"sequence": 5, "typical_saving": {"value": 357, "currency": "GBP"}, "indicative_cost": "\u00a31,600 - \u00a32,400", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 47}, {"sequence": 6, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 51}, {"sequence": 7, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 60}], "co2_emissions_potential": 4.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 433, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 91}, {"sequence": 2, "typical_saving": {"value": 429, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 103, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3463, "impact_of_loft_insulation": -622, "impact_of_solid_wall_insulation": -5598, "space_heating_existing_dwelling": 15379}, "energy_consumption_current": 688, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 281, "environmental_impact_current": 22, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 116, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100050398328, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HG2 7NA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARROGATE", "built_form": 2, "created_at": "2018-02-22 18:04:27.000000", "door_count": 0, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "3, Applegarth Homes", "address_line_2": "Knaresborough Road", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-01-24", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6, "quantity": "metres"}}, "total_floor_area": 45, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "false", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.6, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "total_floor_area": {"value": 45, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 598, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 533, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 59}], "co2_emissions_potential": 2.9, "energy_rating_potential": 62, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1622, "impact_of_loft_insulation": -4547, "impact_of_cavity_insulation": -1582, "space_heating_existing_dwelling": 10305}, "energy_consumption_current": 413, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 369, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 59, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 21087125, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU9 5SJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 2, "created_at": "2018-10-28 10:00:17.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 4051}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "17, Springdale Close", "assessment_type": "RdSAP", "completion_date": "2018-10-28", "inspection_date": "2018-09-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 59.94, "quantity": "square metres"}, "party_wall_length": {"value": 6.81, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.05, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 422, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 404, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.0, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 84, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2616, "space_heating_existing_dwelling": 5408}, "energy_consumption_current": 239, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 92, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100120960829, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "OX28 4EZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WITNEY", "built_form": 2, "created_at": "2018-02-13 17:08:26.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1285}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "34, St. Marys Mead", "assessment_type": "RdSAP", "completion_date": "2018-02-13", "inspection_date": "2018-02-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-02-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.69, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 18.69, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.69, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 18.69, "quantity": "square metres"}, "party_wall_length": {"value": 2.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 592, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 446, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 55, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.4, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 186, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2764, "impact_of_loft_insulation": -116, "space_heating_existing_dwelling": 7678}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 106, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050380923, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO61 3JN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "YORK", "built_form": 2, "created_at": "2018-07-25 08:02:01.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1181}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "18, Oxenby Place", "address_line_2": "Easingwold", "assessment_type": "RdSAP", "completion_date": "2018-07-25", "inspection_date": "2018-07-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 49, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, coal", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.6, "quantity": "square metres"}, "party_wall_length": {"value": 9, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.07, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 449, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 36, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 326, "currency": "GBP"}, "hot_water_cost_current": {"value": 140, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 46}, {"sequence": 4, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 58}, {"sequence": 6, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.0, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2486, "space_heating_existing_dwelling": 6196}, "energy_consumption_current": 351, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 118, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 95, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 200000173022, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SO23 0QR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WINCHESTER", "built_form": 2, "created_at": "2018-04-11 13:27:00.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16284}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "56, Fivefields Road", "assessment_type": "RdSAP", "completion_date": "2018-04-11", "inspection_date": "2018-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.93, "quantity": "square metres"}, "party_wall_length": {"value": 6.77, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 34.93, "quantity": "square metres"}, "party_wall_length": {"value": 6.77, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.09, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 406, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 50, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 375, "currency": "GBP"}, "hot_water_cost_current": {"value": 129, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2720, "impact_of_loft_insulation": -203, "space_heating_existing_dwelling": 6552}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 83, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 21008799, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HU7 4SQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 4, "created_at": "2018-04-11 20:51:08.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "188, Axminster Close", "address_line_2": "Bransholme", "assessment_type": "RdSAP", "completion_date": "2018-04-11", "inspection_date": "2018-04-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 86, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.2, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 43.2, "quantity": "square metres"}, "party_wall_length": {"value": 18, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 451, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 76}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2110, "space_heating_existing_dwelling": 7560}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 77, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100090144267, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB23 1JW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 2, "created_at": "2018-05-31 23:00:24.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 2, "main_heating_data_source": 1, "main_heating_index_number": 15101}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "30, High Street", "address_line_2": "Haslingfield", "assessment_type": "RdSAP", "completion_date": "2018-05-31", "inspection_date": "2018-05-31", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-05-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.38, "quantity": "square metres"}, "party_wall_length": {"value": 7.53, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 23.38, "quantity": "square metres"}, "party_wall_length": {"value": 6.53, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.31, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 443, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 300, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 111, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2415, "impact_of_loft_insulation": -137, "impact_of_solid_wall_insulation": -2523, "space_heating_existing_dwelling": 7721}, "energy_consumption_current": 271, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 65, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100080063268, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SG18 8RT", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIGGLESWADE", "built_form": 2, "created_at": "2018-08-08 11:11:41", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 631, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "25, Cambridge Road", "address_line_2": "Dunton", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-08-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 2, "percent_roof_area": 55}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, coal", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.78, "quantity": "square metres"}, "party_wall_length": {"value": 7.33, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 20.07, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 43.03, "quantity": "square metres"}, "party_wall_length": {"value": 7.33, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.07, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 895, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 623, "currency": "GBP"}, "hot_water_cost_current": {"value": 353, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 39}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 39}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a32,000 - \u00a33,000", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 55}], "co2_emissions_potential": 3.9, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 422, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 329, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 86}], "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2400, "space_heating_existing_dwelling": 10557}, "energy_consumption_current": 385, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 227, "environmental_impact_current": 33, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 55, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100110633426, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 66% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE20 9EW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWCASTLE UPON TYNE", "built_form": 1, "created_at": "2018-11-09 17:11:53", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9720}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "49, Whinfell Road", "address_line_2": "Ponteland", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-11-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 231, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.736, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 231.16, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 69.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 66, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1381, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 147, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1261, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 126, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "co2_emissions_potential": 5.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 109, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 108, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2363, "space_heating_existing_dwelling": 26822}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 150, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 41, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 27} +{"uprn": 100010682610, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "WN8 6XW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SKELMERSDALE", "built_form": 1, "created_at": "2018-11-13 18:38:54.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 5921}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "55, Kingsbury Court", "assessment_type": "RdSAP", "completion_date": "2018-11-13", "inspection_date": "2018-11-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-11-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 45.79, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 30.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 310, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.99, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 6.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 593, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 146, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 507, "currency": "GBP"}, "hot_water_cost_current": {"value": 191, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a370", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 4, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 6, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 145, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3306, "impact_of_loft_insulation": -633, "space_heating_existing_dwelling": 9027}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 107, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010077720, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CW1 5EN", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CREWE", "built_form": 4, "created_at": "2018-10-31 22:05:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17610}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Gresty Terrace", "assessment_type": "RdSAP", "completion_date": "2018-10-31", "inspection_date": "2018-10-29", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-31", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.99, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 8.99, "quantity": "square metres"}, "party_wall_length": {"value": 3.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 2.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.88, "quantity": "square metres"}, "party_wall_length": {"value": 11.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 19.88, "quantity": "square metres"}, "party_wall_length": {"value": 11.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.3, "quantity": "square metres"}, "party_wall_length": {"value": 5.65, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.65, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 600, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 553, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1823, "impact_of_loft_insulation": -2607, "impact_of_solid_wall_insulation": -1203, "space_heating_existing_dwelling": 11060}, "energy_consumption_current": 279, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 162, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100031589522, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG7 6GZ", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NOTTINGHAM", "built_form": 4, "created_at": "2018-09-15 13:12:52.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "54, Russell Road", "assessment_type": "RdSAP", "completion_date": "2018-09-15", "inspection_date": "2018-09-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.58, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.95, "quantity": "square metres"}, "party_wall_length": {"value": 19, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.56, "quantity": "metres"}, "total_floor_area": {"value": 35.95, "quantity": "square metres"}, "party_wall_length": {"value": 19, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1807, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.6, "energy_rating_average": 60, "energy_rating_current": 19, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 526, "currency": "GBP"}, "hot_water_cost_current": {"value": 206, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 383, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 99, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 41}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 42}, {"sequence": 4, "typical_saving": {"value": 929, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 900, "improvement_type": "T2", "improvement_details": {"improvement_number": 50}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 288, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 879, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 65, "environmental_impact_rating": 90}, {"sequence": 2, "typical_saving": {"value": 831, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 67, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 1032, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1248, "impact_of_loft_insulation": -3255, "impact_of_solid_wall_insulation": -2613, "space_heating_existing_dwelling": 10916}, "energy_consumption_current": 543, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 124, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "G", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 92, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10033571686, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW1V 2RW", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-09-15 09:45:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 950, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "Hopkinson House", "address_line_3": "88 Vauxhall Bridge Road", "assessment_type": "RdSAP", "completion_date": "2018-09-15", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 34, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-09-15", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 33.6, "quantity": "square metres"}, "party_wall_length": {"value": 11.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 199, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 30, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 129, "currency": "GBP"}, "hot_water_cost_current": {"value": 178, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.4, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 30, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 178, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3215, "impact_of_solid_wall_insulation": -1253, "space_heating_existing_dwelling": 2018}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 228, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.4, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100040048866, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR1 3RY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "TRURO", "built_form": 2, "created_at": "2018-09-19 21:42:18.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "99, Rosedale Road", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 67, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.49, "quantity": "square metres"}, "party_wall_length": {"value": 6.09, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.09, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 33.49, "quantity": "square metres"}, "party_wall_length": {"value": 6.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.09, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 428, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 398, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 327, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2245, "space_heating_existing_dwelling": 6366}, "energy_consumption_current": 214, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 96, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10007060151, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "GU23 6EH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WOKING", "built_form": 4, "created_at": "2018-02-17 15:27:04.000000", "door_count": 5, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8867}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "2, Heath Mews", "address_line_2": "Ripley", "assessment_type": "RdSAP", "completion_date": "2018-02-17", "inspection_date": "2018-02-16", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55, "quantity": "square metres"}, "party_wall_length": {"value": 11, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 55, "quantity": "square metres"}, "party_wall_length": {"value": 11, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 455, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 127, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 433, "currency": "GBP"}, "hot_water_cost_current": {"value": 124, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "2,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2619, "space_heating_existing_dwelling": 6839}, "energy_consumption_current": 155, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 75, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10024206596, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Granite or whinstone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "LL24 0HA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BETWS-Y-COED", "built_form": 1, "created_at": "2018-04-13 15:08:29", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": 1, "main_heating_number": 1, "main_heating_control": 2206, "main_heating_category": 4, "main_heating_fraction": 1, "sap_main_heating_code": 221, "mcs_installed_heat_pump": "true", "central_heating_pump_age": 2, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Ground source heat pump, radiators, electric", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Rhyd y Creua Farm", "address_line_2": "Llanrwst Road", "assessment_type": "RdSAP", "completion_date": "2018-04-13", "inspection_date": "2018-04-03", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 172, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-04-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [7], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 100.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 37.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 100.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 47, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 23.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 2741, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 11, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 147, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 2, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1392, "currency": "GBP"}, "hot_water_cost_current": {"value": 152, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 1118, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 66}, {"sequence": 4, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 16}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 588, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 85}], "co2_emissions_potential": 3.4, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 93, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 152, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2989, "impact_of_loft_insulation": -1652, "impact_of_solid_wall_insulation": -15392, "space_heating_existing_dwelling": 36823}, "energy_consumption_current": 373, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 108, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10090980689, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "To unheated space, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD7 1NH", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BRADFORD", "built_form": 6, "created_at": "2018-04-13 12:51:32.000000", "door_count": 1, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2603, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 308", "address_line_2": "Legrams Mill Residence", "address_line_3": "Legrams Lane", "assessment_type": "RdSAP", "completion_date": "2018-04-13", "inspection_date": "2018-04-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 35, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "registration_date": "2018-04-13", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 700, "floor_heat_loss": 2, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.28, "quantity": "square metres"}, "party_wall_length": {"value": 14.4, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 4.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 298, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 29, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 176, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 163, "currency": "GBP"}, "indicative_cost": "\u00a3400 - \u00a3600", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 31, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 219, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 183, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 120, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1449, "space_heating_existing_dwelling": 2057}, "energy_consumption_current": 320, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 336, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 3, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 207160788, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EN3 6QT", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ENFIELD", "built_form": 3, "created_at": "2018-04-18 16:44:31.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "No system present: electric heaters assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "36, Cobbett Close", "assessment_type": "RdSAP", "completion_date": "2018-04-18", "inspection_date": "2018-04-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 1}, "total_floor_area": 31, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "true", "registration_date": "2018-04-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.35, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 30.53, "quantity": "square metres"}, "party_wall_length": {"value": 10.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 215, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 39, "currency": "GBP"}, "main_heating_controls": [{"description": "None", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 93, "currency": "GBP"}, "hot_water_cost_current": {"value": 223, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 210, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 71}], "co2_emissions_potential": 1.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 242, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 84, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 210, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "hot_water_cost_potential": {"value": 116, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1626, "space_heating_existing_dwelling": 1092}, "energy_consumption_current": 295, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 287, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 44026586, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Full secondary glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 33% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "ME1 1NJ", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ROCHESTER", "built_form": 2, "created_at": "2018-04-18 16:50:55.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1 Haywards House", "address_line_2": "Corporation Street", "assessment_type": "RdSAP", "completion_date": "2018-04-18", "inspection_date": "2018-04-18", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-04-18", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.03, "quantity": "square metres"}, "party_wall_length": {"value": 5.06, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 486, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 57, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 244, "currency": "GBP"}, "hot_water_cost_current": {"value": 115, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 179, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 66, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.5, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 34, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 115, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2028, "impact_of_solid_wall_insulation": -2678, "space_heating_existing_dwelling": 5952}, "energy_consumption_current": 359, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 196, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 90093015, "roofs": [{"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WV14 9HU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BILSTON", "built_form": 4, "created_at": "2018-06-04 12:13:09.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8867}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "93, Horace Street", "address_line_2": "Coseley", "assessment_type": "RdSAP", "completion_date": "2018-06-04", "inspection_date": "2018-06-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 51, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-06-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.34, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.24, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 25.34, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 363, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 328, "currency": "GBP"}, "hot_water_cost_current": {"value": 119, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.8, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2510, "impact_of_loft_insulation": -270, "space_heating_existing_dwelling": 5389}, "energy_consumption_current": 256, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 86, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100050380359, "roofs": [{"description": "Pitched, 270 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "YO61 2NT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "YORK", "built_form": 2, "created_at": "2018-08-24 09:20:36.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17516}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "Spring Dallah", "address_line_2": "Main Street", "address_line_3": "Helperby", "assessment_type": "RdSAP", "completion_date": "2018-08-24", "inspection_date": "2018-08-23", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 135, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-08-24", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.78, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 67.69, "quantity": "square metres"}, "party_wall_length": {"value": 14.83, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 26.28, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 67.69, "quantity": "square metres"}, "party_wall_length": {"value": 14.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 961, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 570, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 69}], "co2_emissions_potential": 4.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 81, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 122, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3488, "impact_of_solid_wall_insulation": -5810, "space_heating_existing_dwelling": 17914}, "energy_consumption_current": 236, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 111, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "E", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 63165784, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF6 2EP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "NORMANTON", "built_form": 2, "created_at": "2018-11-15 19:38:48.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "150a, Castleford Road", "assessment_type": "RdSAP", "completion_date": "2018-11-15", "inspection_date": "2018-11-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 70, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.75, "quantity": "metres"}, "total_floor_area": {"value": 69.96, "quantity": "square metres"}, "party_wall_length": {"value": 8.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 25.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 414, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 414, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2274, "space_heating_existing_dwelling": 6846}, "energy_consumption_current": 198, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 198, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100080834571, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "AL5 5HS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARPENDEN", "built_form": 3, "created_at": "2018-10-02 09:45:12.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "main_heating_data_source": 1, "main_heating_index_number": 15241}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "28, Noke Shot", "assessment_type": "RdSAP", "completion_date": "2018-10-02", "inspection_date": "2018-10-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 134, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-10-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.27, "quantity": "square metres"}, "party_wall_length": {"value": 6.73, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 43.94, "quantity": "square metres"}, "party_wall_length": {"value": 6.73, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.79, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.87, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 623, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 629, "currency": "GBP"}, "hot_water_cost_current": {"value": 138, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.7, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 98, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2980, "impact_of_loft_insulation": -515, "space_heating_existing_dwelling": 12076}, "energy_consumption_current": 168, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 114, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10000078075, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TR2 4EX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "TRURO", "built_form": 1, "created_at": "2018-08-08 20:52:33.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10499}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Halivick Farm", "address_line_2": "Terras", "address_line_3": "Grampound Road", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-07-30", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.79, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.12, "quantity": "metres"}, "total_floor_area": {"value": 44.62, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 29.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.39, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 690, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 263, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 379, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 65}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 101, "environmental_impact_rating": 93}], "co2_emissions_potential": 0.3, "energy_rating_potential": 101, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 132, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3715, "impact_of_solid_wall_insulation": -9104, "space_heating_existing_dwelling": 15647}, "energy_consumption_current": 258, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": -47, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "E", "environmental_impact_potential": 93, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100090505677, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 83% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG10 4QU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LOUGHTON", "built_form": 1, "created_at": "2018-04-19 10:30:10.000000", "door_count": 3, "glazed_area": 2, "glazing_gap": 6, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10201}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "70, High Road", "assessment_type": "RdSAP", "completion_date": "2018-04-19", "inspection_date": "2018-04-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 128, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-04-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 64, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 38, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 64, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 701, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 89, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 650, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.8, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3431, "space_heating_existing_dwelling": 13222}, "energy_consumption_current": 195, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 120, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 36257, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 20% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "BS16 2NL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-08-10 12:05:10.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "23, Cunningham Gardens", "assessment_type": "RdSAP", "completion_date": "2018-08-10", "inspection_date": "2018-08-07", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 2.15}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-08-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 5.074, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 290, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.05, "quantity": "square metres"}, "party_wall_length": {"value": 6.27, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.41, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 277, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 236, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1861, "space_heating_existing_dwelling": 3647}, "energy_consumption_current": 197, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 159, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 100070651505, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Solid brick, with external insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 86% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV1 4HB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 4, "created_at": "2018-08-05 19:36:40.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15701}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "153, George Street", "assessment_type": "RdSAP", "completion_date": "2018-08-05", "inspection_date": "2018-08-04", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-08-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.46, "quantity": "square metres"}, "party_wall_length": {"value": 24.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.8, "quantity": "metres"}, "total_floor_area": {"value": 42.46, "quantity": "square metres"}, "party_wall_length": {"value": 24.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.7, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.02, "quantity": "square metres"}, "party_wall_length": {"value": 3.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 86, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 817, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.7, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 664, "currency": "GBP"}, "hot_water_cost_current": {"value": 101, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 125, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2197, "impact_of_loft_insulation": -4314, "impact_of_cavity_insulation": -361, "space_heating_existing_dwelling": 15022}, "energy_consumption_current": 290, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 168, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 14, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 202072939, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Full secondary glazing", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NW2 5SB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-21 19:21:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16834}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "20, Lydford Road", "assessment_type": "RdSAP", "completion_date": "2018-11-21", "inspection_date": "2018-11-19", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 111, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-11-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.87, "quantity": "square metres"}, "party_wall_length": {"value": 16.86, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 32.87, "quantity": "square metres"}, "party_wall_length": {"value": 16.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.9, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 32.87, "quantity": "square metres"}, "party_wall_length": {"value": 16.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 3.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 1, "roof_construction": 7, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.43, "quantity": "square metres"}, "party_wall_length": 3.3, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 8, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 6.43, "quantity": "square metres"}, "party_wall_length": 3.3, "heat_loss_perimeter": {"value": 3.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 489, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 122, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 408, "currency": "GBP"}, "hot_water_cost_current": {"value": 131, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 90, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.4, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 83, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2837, "impact_of_cavity_insulation": -1209, "space_heating_existing_dwelling": 8604}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 71, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120869938, "roofs": [{"description": {"value": "Pitched, 75 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "OX10 7NE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLINGFORD", "built_form": 2, "created_at": "2018-10-03 16:38:55.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17821}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "55, Fane Drive", "address_line_2": "Berinsfield", "assessment_type": "RdSAP", "completion_date": "2018-10-03", "inspection_date": "2018-10-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "registration_date": "2018-10-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.32, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.1, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "75mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 488, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 58, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 425, "currency": "GBP"}, "hot_water_cost_current": {"value": 123, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 307, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 58, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2665, "impact_of_loft_insulation": -648, "space_heating_existing_dwelling": 8554}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 97, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100031586329, "roofs": [{"description": {"value": "Pitched, 350 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG5 3GR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 1, "created_at": "2018-10-02 17:23:19.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "29, Ridsdale Road", "assessment_type": "RdSAP", "completion_date": "2018-10-02", "inspection_date": "2018-10-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-10-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 255, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.96, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 29.39, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 48.11, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 29.75, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 776, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 66, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 449, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 264, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 62, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.6, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 66, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2224, "impact_of_solid_wall_insulation": -5646, "space_heating_existing_dwelling": 14107}, "energy_consumption_current": 264, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 93, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 47, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100031765017, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ST16 1UY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STAFFORD", "built_form": 2, "created_at": "2018-09-15 17:05:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 6, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16396}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat", "address_line_2": "22, Burnett Court", "assessment_type": "RdSAP", "completion_date": "2018-09-15", "inspection_date": "2018-09-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 62, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-09-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 61.92, "quantity": "square metres"}, "party_wall_length": {"value": 8.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.19, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 296, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 278, "currency": "GBP"}, "hot_water_cost_current": {"value": 116, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.8, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2492, "space_heating_existing_dwelling": 4173}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 164, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100030326580, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "DE23 4EE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DERBY", "built_form": 1, "created_at": "2018-02-28 14:47:13.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10462}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "7, Keats Avenue", "address_line_2": "Littleover", "assessment_type": "RdSAP", "completion_date": "2018-02-28", "inspection_date": "2018-02-28", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 139, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 7, "registration_date": "2018-02-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.47, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 53.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.01, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 5.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.55, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1344, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.8, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 136, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 784, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 46}, {"sequence": 2, "typical_saving": {"value": 252, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 54}, {"sequence": 3, "typical_saving": {"value": 83, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 70, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 62}, {"sequence": 7, "typical_saving": {"value": 105, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 8, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 73}], "co2_emissions_potential": 3.5, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 89, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 135, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 59}}], "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2838, "impact_of_cavity_insulation": -4882, "space_heating_existing_dwelling": 24448}, "energy_consumption_current": 318, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.04r01", "energy_consumption_potential": 140, "environmental_impact_current": 43, "fixed_lighting_outlets_count": 25, "current_energy_efficiency_band": "E", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 56, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100022226971, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "IG3 8NY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ILFORD", "built_form": 1, "created_at": "2018-04-30 07:59:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17816}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "198, Meads Lane", "assessment_type": "RdSAP", "completion_date": "2018-04-30", "inspection_date": "2018-04-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 116, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 35.55, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "L"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.302, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 23.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "Y", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.11, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 624, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 482, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 294, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2282, "impact_of_loft_insulation": -837, "impact_of_solid_wall_insulation": -2086, "space_heating_existing_dwelling": 11407}, "energy_consumption_current": 178, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 83, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 34, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 34} +{"uprn": 100040705459, "roofs": [{"description": {"value": "Pitched, 25 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Roof room(s), ceiling insulated", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Partial secondary glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 41% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH21 1DZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "WIMBORNE", "built_form": 1, "created_at": "2018-03-06 14:38:51", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 116, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "The Coach House", "address_line_2": "18 King Street", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-03-05", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 155, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 7, "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 62.19, "quantity": "square metres"}, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "E", "roof_insulation_thickness": "250mm"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 92.4, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 37.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "25mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 13.33, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 41, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1758, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 9.1, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 135, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 4, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 777, "currency": "GBP"}, "hot_water_cost_current": {"value": 231, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 39}, {"sequence": 2, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 45}, {"sequence": 3, "typical_saving": {"value": 179, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 148, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a365", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 54}, {"sequence": 6, "typical_saving": {"value": 417, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 73}, {"sequence": 8, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 9, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 85, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 87, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 55, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 298, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 257, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 601, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2994, "impact_of_loft_insulation": -672, "impact_of_cavity_insulation": -1904, "space_heating_existing_dwelling": 20909}, "energy_consumption_current": 373, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 70, "calculation_software_version": "2.0.x", "energy_consumption_potential": 110, "environmental_impact_current": 38, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 3455079399, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 93% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST4 2EQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 4, "created_at": "2018-09-10 15:51:38.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "39, Queen Anne Street", "assessment_type": "RdSAP", "completion_date": "2018-09-10", "inspection_date": "2018-08-22", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-09-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.8, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.25, "quantity": "square metres"}, "party_wall_length": {"value": 11.01, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.64, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.85, "quantity": "metres"}, "total_floor_area": {"value": 39.25, "quantity": "square metres"}, "party_wall_length": {"value": 11.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.83, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.66, "quantity": "square metres"}, "party_wall_length": {"value": 3.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.38, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.85, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.77, "quantity": "square metres"}, "party_wall_length": {"value": 7.63, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 93, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 1037, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.9, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 809, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 136, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 3, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.6, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2223, "impact_of_loft_insulation": -4932, "impact_of_cavity_insulation": -340, "impact_of_solid_wall_insulation": -3064, "space_heating_existing_dwelling": 18383}, "energy_consumption_current": 347, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 207, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 14} +{"uprn": 10010720459, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SK13 6NW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "GLOSSOP", "built_form": 4, "created_at": "2018-08-08 13:53:14.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 117, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "8, Lyne Avenue", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-08-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 100, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.07, "quantity": "square metres"}, "party_wall_length": {"value": 11.95, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.53, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 50.07, "quantity": "square metres"}, "party_wall_length": {"value": 11.95, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.53, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1116, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.1, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 135, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 650, "currency": "GBP"}, "hot_water_cost_current": {"value": 201, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": 60, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 167, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 5, "typical_saving": {"value": 202, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 2.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 110, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 59, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 299, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2901, "impact_of_loft_insulation": -384, "impact_of_cavity_insulation": -1962, "space_heating_existing_dwelling": 14755}, "energy_consumption_current": 402, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 156, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 71, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100060540897, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "GU14 6TB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FARNBOROUGH", "built_form": 3, "created_at": "2018-08-09 20:04:48.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 6, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1952}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "22, Cumbria Court", "assessment_type": "RdSAP", "completion_date": "2018-08-09", "inspection_date": "2018-08-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-08-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 312, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 31.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.99, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.91, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 31.64, "quantity": "square metres"}, "party_wall_length": {"value": 8.99, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 409, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 92, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 387, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 302, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.1, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2435, "impact_of_loft_insulation": -189, "space_heating_existing_dwelling": 6479}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 97, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100061245985, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ME8 9AY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GILLINGHAM", "built_form": 1, "created_at": "2018-11-29 19:01:37.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17553}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "43, Bettescombe Road", "assessment_type": "RdSAP", "completion_date": "2018-11-29", "inspection_date": "2018-11-28", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 105, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 79.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 34.12, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.75, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 14.36, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 932, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.5, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 693, "currency": "GBP"}, "hot_water_cost_current": {"value": 135, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 52}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 318, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.9, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 81, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2933, "space_heating_existing_dwelling": 13856}, "energy_consumption_current": 297, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 154, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 10093387091, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO17 6EB", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "FAREHAM", "built_form": 3, "created_at": "2018-07-04 11:05:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "19c, High Street", "address_line_2": "Southwick", "assessment_type": "RdSAP", "completion_date": "2018-07-04", "inspection_date": "2018-06-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 100, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-04", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 3, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 99.61, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 31.6, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1263, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 757, "currency": "GBP"}, "hot_water_cost_current": {"value": 196, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 34}, {"sequence": 3, "typical_saving": {"value": 272, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 41}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a3585 - \u00a3725", "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 42}, {"sequence": 5, "typical_saving": {"value": 78, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 45}], "co2_emissions_potential": 5.6, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 93, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 588, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 421, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 162, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2019, "impact_of_loft_insulation": -1313, "space_heating_existing_dwelling": 13376}, "energy_consumption_current": 490, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 20, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 330, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "E", "environmental_impact_potential": 45, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100061903244, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 65% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BN13 3PP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WORTHING", "built_form": 1, "created_at": "2018-06-19 18:29:26.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, Silver Birch Drive", "assessment_type": "RdSAP", "completion_date": "2018-06-19", "inspection_date": "2018-06-18", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 9.24, "wall_dry_lined": "N", "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.12, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 22.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 36.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 7.02, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 14.93, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.97, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.2, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 4.24, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "J", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 65, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 668, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 509, "currency": "GBP"}, "hot_water_cost_current": {"value": 169, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 122, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.8, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 142, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2925, "impact_of_loft_insulation": -625, "space_heating_existing_dwelling": 10236}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 91, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 20, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 200004177660, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CB1 3EF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CAMBRIDGE", "built_form": 2, "created_at": "2018-03-11 10:44:37.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "36, Cromwell Road", "assessment_type": "RdSAP", "completion_date": "2018-03-11", "inspection_date": "2018-03-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 26.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.8, "quantity": "square metres"}, "party_wall_length": {"value": 4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 547, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 370, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 129, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1743, "impact_of_cavity_insulation": -389, "impact_of_solid_wall_insulation": -2891, "space_heating_existing_dwelling": 9754}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 78, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 39064799, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "WA12 8PP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWTON-LE-WILLOWS", "built_form": 2, "created_at": "2018-08-15 21:24:16.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Woburn Avenue", "assessment_type": "RdSAP", "completion_date": "2018-08-15", "inspection_date": "2018-08-15", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-08-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.85, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.91, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 37.4, "quantity": "square metres"}, "party_wall_length": {"value": 6.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.91, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 613, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 517, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.6, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1830, "space_heating_existing_dwelling": 8477}, "energy_consumption_current": 243, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100050509958, "roofs": [{"description": {"value": "Pitched, *** INVALID INPUT Code : 57 *** loft insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS25 6DE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 2, "created_at": "2018-08-07 15:09:30.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17983}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "148, Springfield Road", "address_line_2": "Sherburn in Elmet", "assessment_type": "RdSAP", "completion_date": "2018-08-07", "inspection_date": "2018-08-03", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.96, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 35.96, "quantity": "square metres"}, "party_wall_length": {"value": 5.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 764, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 734, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 66}], "co2_emissions_potential": 3.1, "energy_rating_potential": 73, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1978, "space_heating_existing_dwelling": 14920}, "energy_consumption_current": 338, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 239, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100021833143, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW8 1DR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-01-16 12:01:58.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 69 Lulworth House", "address_line_2": "Dorset Road", "assessment_type": "RdSAP", "completion_date": "2018-01-16", "inspection_date": "2018-01-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.565, "quantity": "metres"}, "total_floor_area": {"value": 63.55, "quantity": "square metres"}, "party_wall_length": {"value": 14.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.79, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 272, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 180, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.1, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 96, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2209, "impact_of_solid_wall_insulation": -2059, "space_heating_existing_dwelling": 3558}, "energy_consumption_current": 144, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 100, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 25, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 24057093, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS48 4SZ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 1, "created_at": "2018-01-08 17:03:23.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16917}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "27, Leighwood Drive", "address_line_2": "Nailsea", "assessment_type": "RdSAP", "completion_date": "2018-01-08", "inspection_date": "2018-01-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 8, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.7, "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 51.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 51.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 663, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 90, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 456, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.6, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2911, "impact_of_loft_insulation": -488, "impact_of_cavity_insulation": -2674, "impact_of_solid_wall_insulation": -355, "space_heating_existing_dwelling": 11667}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 85, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100011346889, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Flat, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Timber frame, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "M28 1ND", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MANCHESTER", "built_form": 2, "created_at": "2018-01-09 13:57:51.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15834}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "41, Birchfield Drive", "address_line_2": "Worsley", "assessment_type": "RdSAP", "completion_date": "2018-01-09", "inspection_date": "2018-01-08", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.35, "quantity": "square metres"}, "party_wall_length": {"value": 6.72, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.61, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 36.35, "quantity": "square metres"}, "party_wall_length": {"value": 6.72, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.54, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.12, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.65, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.21, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 580, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.4, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 465, "currency": "GBP"}, "hot_water_cost_current": {"value": 108, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2211, "impact_of_loft_insulation": -466, "space_heating_existing_dwelling": 9369}, "energy_consumption_current": 207, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 102, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100100159093, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SA18 1AU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "AMMANFORD", "built_form": 4, "created_at": "2018-10-17 11:43:42.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 28, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2111, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15091}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Bryn Road", "address_line_2": "Upper Brynamman", "assessment_type": "RdSAP", "completion_date": "2018-10-17", "inspection_date": "2018-10-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 500, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.24, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 1.8, "quantity": "metres"}, "total_floor_area": {"value": 26.24, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.4, "quantity": "square metres"}, "party_wall_length": 4.4, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 715, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 39, "lighting_cost_current": {"value": 109, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 511, "currency": "GBP"}, "hot_water_cost_current": {"value": 155, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 38}, {"sequence": 2, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 43}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 45}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 46}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 47}, {"sequence": 6, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 50}, {"sequence": 7, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 59}, {"sequence": 8, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.5, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 18, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 42, "environmental_impact_rating": 38}}], "hot_water_cost_potential": {"value": 127, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3565, "impact_of_loft_insulation": -2203, "impact_of_cavity_insulation": -685, "impact_of_solid_wall_insulation": -2148, "space_heating_existing_dwelling": 11872}, "energy_consumption_current": 332, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 14, "environmental_impact_current": 36, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 81, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100040350453, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"addendum_numbers": [8]}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX17 2AS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CREDITON", "built_form": 2, "created_at": "2018-12-06 15:53:34", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 18118}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "22, Stanbury Court", "assessment_type": "RdSAP", "completion_date": "2018-12-06", "inspection_date": "2018-12-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.4, "quantity": "metres"}}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-12-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"pv_arrays": [{"pitch": 2, "peak_power": {"value": 2.3, "quantity": "kW"}, "orientation": 5, "overshading": 1, "pv_connection": 2}]}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [11], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.36, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 120, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 40.81, "quantity": "square metres"}, "party_wall_length": {"value": 4.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.26, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 280, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 0.3, "energy_rating_average": 60, "energy_rating_current": 92, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 259, "currency": "GBP"}, "hot_water_cost_current": {"value": 64, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 93, "environmental_impact_rating": 94}], "co2_emissions_potential": 0.2, "energy_rating_potential": 93, "lighting_cost_potential": {"value": 42, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1407, "impact_of_loft_insulation": -461, "space_heating_existing_dwelling": 3667}, "energy_consumption_current": 38, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 23, "environmental_impact_current": 92, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "A", "environmental_impact_potential": 94, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 8, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10009586433, "roofs": [{"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 62% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO31 4JF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-10-23 23:15:25", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Coach House", "address_line_2": "High Street", "address_line_3": "Hamble", "assessment_type": "RdSAP", "completion_date": "2018-10-23", "inspection_date": "2018-10-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 97, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 48.34, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.34, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 995, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 405, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 95, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 394, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 144, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 6, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2353, "impact_of_solid_wall_insulation": -2630, "space_heating_existing_dwelling": 18427}, "energy_consumption_current": 321, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.0.x", "energy_consumption_potential": 66, "environmental_impact_current": 48, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100062462535, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 63% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG25 3AB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "BASINGSTOKE", "built_form": 2, "created_at": "2018-10-18 12:38:29", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1187}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, oil", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "5, Berrydown Lane", "address_line_2": "Overton", "assessment_type": "RdSAP", "completion_date": "2018-10-18", "inspection_date": "2018-10-18", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 78.04, "quantity": "square metres"}, "party_wall_length": {"value": 9.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 31.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 63, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 683, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 380, "currency": "GBP"}, "hot_water_cost_current": {"value": 160, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 94, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 53, "environmental_impact_rating": 48}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 4, "typical_saving": {"value": 9, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 18, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 7, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 8, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}, {"sequence": 9, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 104, "environmental_impact_rating": 97}], "co2_emissions_potential": 0.2, "energy_rating_potential": 104, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 57, "environmental_impact_rating": 51}}], "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2791, "impact_of_loft_insulation": -1709, "impact_of_cavity_insulation": -1218, "space_heating_existing_dwelling": 11661}, "energy_consumption_current": 321, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": -46, "environmental_impact_current": 39, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "E", "environmental_impact_potential": 97, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 78, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100031811667, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WS6 7BH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALSALL", "built_form": 2, "created_at": "2018-10-19 16:38:34.000000", "door_count": 1, "glazed_area": 2, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16327}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, New Horse Road", "address_line_2": "Cheslyn Hay", "assessment_type": "RdSAP", "completion_date": "2018-10-19", "inspection_date": "2018-10-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.83, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 38.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.05, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 549, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 513, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.8, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 65, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 55, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1891, "impact_of_loft_insulation": -410, "space_heating_existing_dwelling": 8851}, "energy_consumption_current": 232, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 134, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 3455023870, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "ST2 7HR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "STOKE-ON-TRENT", "built_form": 2, "created_at": "2018-07-03 08:49:43.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10112}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "36, Clive Avenue", "assessment_type": "RdSAP", "completion_date": "2018-07-03", "inspection_date": "2018-07-02", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 80, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 295, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 48.08, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.44, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.37, "quantity": "metres"}, "total_floor_area": {"value": 46.07, "quantity": "square metres"}, "party_wall_length": {"value": 7.12, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.06, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 525, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 476, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2114, "space_heating_existing_dwelling": 9046}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100031257381, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG17 5JX", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "SUTTON-IN-ASHFIELD", "built_form": 2, "created_at": "2018-03-21 08:15:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16497}], "immersion_heating_type": "NA", "secondary_heating_type": 604, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "42, Sotheby Avenue", "assessment_type": "RdSAP", "completion_date": "2018-03-21", "inspection_date": "2018-03-20", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 80, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.825, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.68, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.39, "quantity": "metres"}, "total_floor_area": {"value": 45.056, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.68, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.88, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 803, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 53, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 483, "currency": "GBP"}, "hot_water_cost_current": {"value": 248, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 66, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 48}, {"sequence": 2, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 3, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 51}, {"sequence": 6, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 58}, {"sequence": 7, "typical_saving": {"value": 180, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 8, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 9, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 10, "typical_saving": {"value": 275, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.7, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 211, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3485, "space_heating_existing_dwelling": 10549}, "energy_consumption_current": 385, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 60, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 121, "environmental_impact_current": 45, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 68, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 200000946636, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NP7 7RN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "ABERGAVENNY", "built_form": 2, "created_at": "2018-03-20 12:06:18.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "The Cloisters", "address_line_3": "18 Pen y Pound", "assessment_type": "RdSAP", "completion_date": "2018-03-20", "inspection_date": "2018-03-15", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 9.57, "quantity": "metres"}}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-03-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 550, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 28.71, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 45.24, "quantity": "square metres"}, "party_wall_length": {"value": 9.77, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 846, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 272, "currency": "GBP"}, "hot_water_cost_current": {"value": 299, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 269, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 89, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 47}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 49}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 50}, {"sequence": 5, "typical_saving": {"value": 208, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.7, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 316, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 254, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2160, "impact_of_solid_wall_insulation": -3046, "space_heating_existing_dwelling": 9473}, "energy_consumption_current": 804, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 351, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 136, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100040911521, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BS27 3HX", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "CHEDDAR", "built_form": 1, "created_at": "2018-02-01 16:49:00", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Willow Tree Cottage", "address_line_2": "Upper North Street", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-01-26", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 47, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.28, "wall_dry_lined": "N", "wall_thickness": 450, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.18, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.6, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "Y", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 3, "sap_alternative_wall": {"wall_area": 9, "wall_dry_lined": "N", "wall_thickness": 450, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1339, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.4, "energy_rating_average": 60, "energy_rating_current": 22, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "No thermostatic control of room temperature", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 373, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 495, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 41, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 12, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 394, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 48}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 53}, {"sequence": 6, "typical_saving": {"value": 325, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 66}], "co2_emissions_potential": 2.0, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 39, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 442, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 355, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1569, "impact_of_loft_insulation": -1017, "impact_of_solid_wall_insulation": -3895, "space_heating_existing_dwelling": 10359}, "energy_consumption_current": 747, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 98, "calculation_software_version": "3.03r05", "energy_consumption_potential": 269, "environmental_impact_current": 30, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "F", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 115, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031523524, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "System built, with external insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 89% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG8 4NQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-01-08 18:18:29.000000", "door_count": 3, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "37, Bramerton Road", "assessment_type": "RdSAP", "completion_date": "2018-01-08", "inspection_date": "2017-11-09", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-01-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 375, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41, "quantity": "square metres"}, "party_wall_length": {"value": 6.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.2, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "150mm"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 440, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 63, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 376, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a31,500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 4, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 86, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2821, "space_heating_existing_dwelling": 5525}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 74, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 200003363700, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "System built, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(other premises below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE1 3TJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-28 08:12:24.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16841}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "true"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "3, Market Yard Mews", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-09-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 8.63}, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 3, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 20.9709, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 8, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 110.11, "quantity": "square metres"}, "party_wall_length": {"value": 25.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 425, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 425, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.5, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1978, "space_heating_existing_dwelling": 6578}, "energy_consumption_current": 129, "has_fixed_air_conditioning": "true", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 129, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 26, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 23, "low_energy_fixed_lighting_outlets_count": 26} +{"uprn": 100061354463, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "KT19 0HB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EPSOM", "built_form": 4, "created_at": "2018-09-11 18:59:28.000000", "door_count": 1, "glazed_area": 2, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17995}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Elm Way", "assessment_type": "RdSAP", "completion_date": "2018-09-11", "inspection_date": "2018-09-11", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-09-11", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 230, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.78, "quantity": "square metres"}, "party_wall_length": {"value": 14.05, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.65, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 38.48, "quantity": "square metres"}, "party_wall_length": {"value": 14.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 553, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 480, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 4, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2007, "impact_of_loft_insulation": -3091, "impact_of_solid_wall_insulation": -1333, "space_heating_existing_dwelling": 10076}, "energy_consumption_current": 237, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 119, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 200001169776, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV1 4RG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 4, "created_at": "2018-05-16 11:48:46.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "10, Brindley Paddocks", "assessment_type": "RdSAP", "completion_date": "2018-05-16", "inspection_date": "2018-02-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-05-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 41.5, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 366, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 369, "currency": "GBP"}, "hot_water_cost_current": {"value": 136, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 85, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2682, "space_heating_existing_dwelling": 5690}, "energy_consumption_current": 165, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 81, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10032998870, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "CF31 5EA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PEN-Y-BONT AR OGWR", "built_form": 2, "created_at": "2018-09-01 15:31:23", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8787}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19", "address_line_2": "Parc Glyn", "assessment_type": "RdSAP", "completion_date": "2018-09-01", "inspection_date": "2018-08-30", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-01", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.77, "quantity": "square metres"}, "party_wall_length": {"value": 7.32, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 34.77, "quantity": "square metres"}, "party_wall_length": {"value": 7.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 361, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 318, "currency": "GBP"}, "hot_water_cost_current": {"value": 134, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 323, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.7, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 67, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2518, "impact_of_loft_insulation": -242, "space_heating_existing_dwelling": 4978}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 53, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10009595530, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Suspended, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 59% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "SO30 4AF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "SOUTHAMPTON", "built_form": 1, "created_at": "2018-05-10 14:43:21", "door_count": 4, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 4, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1553}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "9, St. Johns Road", "address_line_2": "Hedge End", "assessment_type": "RdSAP", "completion_date": "2018-05-10", "inspection_date": "2018-05-09", "extensions_count": 2, "measurement_type": 1, "total_floor_area": 166, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 7, "registration_date": "2018-05-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"floor_area": 15.22, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": 8.88}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.16, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.95, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 40.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.64, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.26, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.71, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 15.25, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.15, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.71, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.32, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.26, "quantity": "metres"}, "total_floor_area": {"value": 19.36, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 11.41, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 59, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 1055, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 121, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 748, "currency": "GBP"}, "hot_water_cost_current": {"value": 196, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a345", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 3, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 260, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 6, "typical_saving": {"value": 311, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.7, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 86, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 68, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 353, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3001, "impact_of_loft_insulation": -145, "space_heating_existing_dwelling": 15193}, "energy_consumption_current": 220, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 102, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100040004664, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 22% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "PL14 3AX", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LISKEARD", "built_form": 4, "created_at": "2018-08-07 15:38:32.000000", "door_count": 0, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Church Street North", "assessment_type": "RdSAP", "completion_date": "2018-08-07", "inspection_date": "2018-08-07", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-08-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 12.57, "quantity": "square metres"}, "insulation": 0, "roof_room_connected": "N", "construction_age_band": "B", "roof_insulation_thickness": "ND"}, "roof_construction": 8, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.99, "quantity": "square metres"}, "party_wall_length": {"value": 15.42, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 27.76, "quantity": "square metres"}, "party_wall_length": {"value": 15.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.28, "quantity": "square metres"}, "party_wall_length": {"value": 5.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 744, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.3, "energy_rating_average": 60, "energy_rating_current": 59, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 711, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 54}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 67}], "co2_emissions_potential": 2.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 19, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 55}}], "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1931, "impact_of_cavity_insulation": -866, "space_heating_existing_dwelling": 14301}, "energy_consumption_current": 298, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 90, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 193, "environmental_impact_current": 52, "fixed_lighting_outlets_count": 9, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 67, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 10014278075, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH1 4HS", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "BOURNEMOUTH", "built_form": 2, "created_at": "2018-11-25 20:29:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230003, "number_of_heaters": 2, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 14 Palmerston Heights", "address_line_2": "32-36, Palmerston Road", "assessment_type": "RdSAP", "completion_date": "2018-11-25", "inspection_date": "2018-11-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 2.92}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 7.008, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 48.77, "quantity": "square metres"}, "party_wall_length": {"value": 9.01, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 93, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.6, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 46, "currency": "GBP"}, "main_heating_controls": [{"description": "Controls for high heat retention storage heaters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 93, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 46, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 166, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1811, "space_heating_existing_dwelling": 967}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 191, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "B", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 42191128, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH45 7NG", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALLASEY", "built_form": 4, "created_at": "2018-12-07 12:00:00.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10241}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Basement flat", "language_code": 1, "property_type": 2, "address_line_1": "167d, Withens Lane", "assessment_type": "RdSAP", "completion_date": "2018-12-07", "inspection_date": "2018-12-07", "extensions_count": 2, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 0}, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 38.93, "quantity": "square metres"}, "party_wall_length": {"value": 8.99, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.15, "quantity": "square metres"}, "party_wall_length": {"value": 12.13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.58, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 380, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.39, "quantity": "square metres"}, "party_wall_length": {"value": 3.13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 417, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 55, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 262, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}, {"sequence": 2, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2194, "impact_of_solid_wall_insulation": -2559, "space_heating_existing_dwelling": 6399}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 125, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100090041178, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CB6 3RS", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "ELY", "built_form": 2, "created_at": "2018-12-12 14:39:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "storage_heaters": [{"index_number": 230003, "number_of_heaters": 2, "high_heat_retention": "true"}, {"index_number": 230002, "number_of_heaters": 3, "high_heat_retention": "true"}, {"index_number": 230001, "number_of_heaters": 1, "high_heat_retention": "true"}], "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2404, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 409, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "25, Berristead Close", "address_line_2": "Wilburton", "assessment_type": "RdSAP", "completion_date": "2018-12-12", "inspection_date": "2018-12-10", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 65, "transaction_type": 14, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-12-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.69, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.12, "quantity": "square metres"}, "party_wall_length": {"value": 6.52, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.69, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.08, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.94, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 638, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Controls for high heat retention storage heaters", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 566, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 45}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 320, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 60}], "co2_emissions_potential": 3.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2093, "space_heating_existing_dwelling": 7171}, "energy_consumption_current": 453, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 276, "environmental_impact_current": 41, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 77, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100080540221, "roofs": [{"description": "Pitched, 50 mm loft insulation", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 51% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HP10 8ET", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HIGH WYCOMBE", "built_form": 1, "created_at": "2018-07-06 17:05:56.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8578}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "2, Katherine Close", "address_line_2": "Penn", "assessment_type": "RdSAP", "completion_date": "2018-07-06", "inspection_date": "2018-07-06", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 155, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-07-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 65.47, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 65.47, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.68, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.97, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.26, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1.91, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.91, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 51, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 967, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.1, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 136, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 693, "currency": "GBP"}, "hot_water_cost_current": {"value": 167, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 77, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 92, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": 95, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 66}, {"sequence": 5, "typical_saving": {"value": 102, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.0, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 167, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2994, "impact_of_loft_insulation": -1580, "space_heating_existing_dwelling": 16061}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 108, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 39, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 10024620262, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV4 9ZG", "hot_water": {"description": {"value": "From main system, plus solar", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "post_town": "COVENTRY", "built_form": 2, "created_at": "2018-08-22 12:20:07", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "solar_water_heating_details": {"shower_types": 4, "solar_water_pump": 0, "solar_collector_details": {"aperture_area": 4.0, "collector_type": 2, "zero_loss_efficiency": 30, "linear_heat_loss_coefficient": 3, "second_order_heat_loss_coefficient": 0.01}, "store_volume_details_known": "N", "solar_panel_collector_pitch": 2, "solar_panel_collector_data_source": 1, "solar_panel_collector_orientation": 7, "solar_panel_collector_overshading": 1}, "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "48, Steinway", "assessment_type": "RdSAP", "completion_date": "2018-08-22", "inspection_date": "2018-02-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 111, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-08-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 340, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 22.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 55.5, "quantity": "square metres"}, "party_wall_length": {"value": 8.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "Y", "habitable_room_count": 6, "heating_cost_current": {"value": 415, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 79, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 415, "currency": "GBP"}, "hot_water_cost_current": {"value": 88, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.5, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 88, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2385, "space_heating_existing_dwelling": 6244}, "energy_consumption_current": 123, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 74, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 22, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 100061879190, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 88% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BN14 7EY", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WORTHING", "built_form": 4, "created_at": "2018-07-19 18:24:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 0.8, "sap_main_heating_code": 402, "main_heating_data_source": 2}, {"has_fghrs": "N", "main_fuel_type": 26, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 2, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 0.2, "sap_main_heating_code": 603, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}, {"description": "Room heaters, mains gas", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "15, Becket Road", "assessment_type": "RdSAP", "completion_date": "2018-07-19", "inspection_date": "2018-07-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Portable electric heaters (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.51, "quantity": "square metres"}, "party_wall_length": {"value": 14.84, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.77, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 30.52, "quantity": "square metres"}, "party_wall_length": {"value": 14.84, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.77, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.64, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.93, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 7.88, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.93, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "sloping_ceiling_insulation_thickness": "AB"}], "low_energy_lighting": 88, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1450, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.4, "energy_rating_average": 60, "energy_rating_current": 29, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 452, "currency": "GBP"}, "hot_water_cost_current": {"value": 277, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 31, "environmental_impact_rating": 24}, {"sequence": 2, "typical_saving": {"value": 375, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 43, "environmental_impact_rating": 36}, {"sequence": 3, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 45, "environmental_impact_rating": 37}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 39}, {"sequence": 5, "typical_saving": {"value": 635, "currency": "GBP"}, "indicative_cost": "7,000", "improvement_type": "T", "improvement_details": {"improvement_number": 27}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 331, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 503, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 89}, {"sequence": 2, "typical_saving": {"value": 380, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 646, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 64}], "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1887, "impact_of_loft_insulation": -3119, "impact_of_solid_wall_insulation": -4225, "space_heating_existing_dwelling": 14808}, "energy_consumption_current": 645, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 107, "environmental_impact_current": 22, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "F", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 110, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200001175303, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "SN10 2PG", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "DEVIZES", "built_form": 2, "created_at": "2018-04-29 14:22:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 191, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "14, St. Matthews Close", "address_line_2": "Rowde", "assessment_type": "RdSAP", "completion_date": "2018-04-29", "inspection_date": "2018-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 59, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-29", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.02, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 28.49, "quantity": "square metres"}, "party_wall_length": {"value": 7.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "NI", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1637, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.5, "energy_rating_average": 60, "energy_rating_current": 16, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 1, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 941, "currency": "GBP"}, "hot_water_cost_current": {"value": 287, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 23, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 106, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 26, "environmental_impact_rating": 36}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 28, "environmental_impact_rating": 38}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a335", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 29, "environmental_impact_rating": 39}, {"sequence": 5, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 32, "environmental_impact_rating": 41}, {"sequence": 6, "typical_saving": {"value": 135, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 36, "environmental_impact_rating": 44}, {"sequence": 7, "typical_saving": {"value": 189, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 50}, {"sequence": 8, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 52}, {"sequence": 9, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.7, "energy_rating_potential": 59, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 24, "environmental_impact_rating": 35}}], "hot_water_cost_potential": {"value": 145, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1778, "impact_of_loft_insulation": -612, "impact_of_cavity_insulation": -1634, "space_heating_existing_dwelling": 10038}, "energy_consumption_current": 654, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 269, "environmental_impact_current": 28, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "G", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 111, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100010126927, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH64 9QH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NESTON", "built_form": 2, "created_at": "2018-06-22 08:06:45.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "44, The Quillet", "assessment_type": "RdSAP", "completion_date": "2018-06-22", "inspection_date": "2018-06-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 113, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-06-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.29, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 44.29, "quantity": "square metres"}, "party_wall_length": {"value": 7.45, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.25, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24.78, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.32, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 767, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 607, "currency": "GBP"}, "hot_water_cost_current": {"value": 130, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 101, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 70}, {"sequence": 5, "typical_saving": {"value": 286, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2277, "impact_of_loft_insulation": -715, "space_heating_existing_dwelling": 11242}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 120, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 15, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100021424807, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "UB3 4QP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HAYES", "built_form": 2, "created_at": "2018-08-27 23:00:22.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Gordon Crescent", "assessment_type": "RdSAP", "completion_date": "2018-08-27", "inspection_date": "2018-08-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-08-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 39.51, "quantity": "square metres"}, "party_wall_length": {"value": 6.89, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.48, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 38.58, "quantity": "square metres"}, "party_wall_length": {"value": 6.89, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.09, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 602, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 56, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 565, "currency": "GBP"}, "hot_water_cost_current": {"value": 103, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.2, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2091, "impact_of_loft_insulation": -3224, "space_heating_existing_dwelling": 10560}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 154, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100040766245, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 43% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BH8 0PF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOURNEMOUTH", "built_form": 4, "created_at": "2018-10-25 12:59:30.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15282}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "24, Shawford Road", "assessment_type": "RdSAP", "completion_date": "2018-10-25", "inspection_date": "2018-10-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 54, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-10-25", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.09, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 27.09, "quantity": "square metres"}, "party_wall_length": {"value": 6.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 388, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 65, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 310, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 56, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 334, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.5, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 10, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 72}}], "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1768, "impact_of_cavity_insulation": -1228, "space_heating_existing_dwelling": 5795}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 48, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10032941018, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NE63 9FJ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ASHINGTON", "built_form": 4, "created_at": "2018-10-19 14:09:07.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17986}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "16, Harrogate Court", "assessment_type": "RdSAP", "completion_date": "2018-10-19", "inspection_date": "2018-10-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 52, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-10-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 52.16, "quantity": "square metres"}, "party_wall_length": {"value": 14, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 323, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 305, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 91, "environmental_impact_rating": 92}], "co2_emissions_potential": 0.6, "energy_rating_potential": 91, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1765, "space_heating_existing_dwelling": 4793}, "energy_consumption_current": 204, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 63, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 92, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100091657668, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": "Low energy lighting in 22% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "IP11 7EX", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "FELIXSTOWE", "built_form": 2, "created_at": "2018-02-06 12:22:55.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1965}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "7a Brownlow Road", "assessment_type": "RdSAP", "completion_date": "2018-02-06", "inspection_date": "2018-02-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 71, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-02-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.9, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 71.44, "quantity": "square metres"}, "party_wall_length": {"value": 9.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 24.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 22, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 570, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 290, "currency": "GBP"}, "hot_water_cost_current": {"value": 153, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 132, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 95, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.8, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 82, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 14, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 110, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2734, "impact_of_solid_wall_insulation": -2535, "space_heating_existing_dwelling": 8676}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.03r05", "energy_consumption_potential": 144, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031796005, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(other premises below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "ST15 0JN", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "STONE", "built_form": 2, "created_at": "2018-05-28 12:39:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Electric storage heaters", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "58a, Pirehill Lane", "assessment_type": "RdSAP", "completion_date": "2018-05-28", "inspection_date": "2018-05-23", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 64, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-28", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 3, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 63.7, "quantity": "square metres"}, "party_wall_length": {"value": 7, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 25.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1018, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.2, "energy_rating_average": 60, "energy_rating_current": 42, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Manual charge control", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 649, "currency": "GBP"}, "hot_water_cost_current": {"value": 278, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 34}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 49, "environmental_impact_rating": 35}, {"sequence": 3, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 50, "environmental_impact_rating": 35}, {"sequence": 4, "typical_saving": {"value": 330, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 59}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 42}], "co2_emissions_potential": 5.2, "energy_rating_potential": 64, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 50, "environmental_impact_rating": 35}, {"sequence": 2, "typical_saving": {"value": 516, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 3, "typical_saving": {"value": 384, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 146, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1981, "impact_of_cavity_insulation": -1753, "space_heating_existing_dwelling": 11417}, "energy_consumption_current": 666, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 484, "environmental_impact_current": 29, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 42, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 113, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090723166, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 29% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "RM16 6PD", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "GRAYS", "built_form": 3, "created_at": "2018-01-22 09:31:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16508}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "end-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "42, Devereux Road", "assessment_type": "RdSAP", "completion_date": "2018-01-22", "inspection_date": "2018-01-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 57, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "false", "registration_date": "2018-01-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 0, "total_floor_area": {"value": 28.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.32, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 15.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 28.4, "quantity": "square metres"}, "party_wall_length": {"value": 7.32, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 384, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 334, "currency": "GBP"}, "hot_water_cost_current": {"value": 209, "currency": "GBP"}, "mechanical_ventilation": 2, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 160, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 317, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 88}], "co2_emissions_potential": 0.6, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 23, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 92}, {"sequence": 2, "typical_saving": {"value": 127, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 133, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3012, "space_heating_existing_dwelling": 3412}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 62, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 72155716, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LS6 4PT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LEEDS", "built_form": 2, "created_at": "2018-11-08 12:59:13.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "109, Parkland Drive", "assessment_type": "RdSAP", "completion_date": "2018-11-08", "inspection_date": "2018-10-27", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 861, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.0, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 638, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 72}], "co2_emissions_potential": 2.7, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 83, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2127, "impact_of_cavity_insulation": -2516, "space_heating_existing_dwelling": 12066}, "energy_consumption_current": 344, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 183, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 72, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 61, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100022287728, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 38% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "KT1 4AR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "KINGSTON UPON THAMES", "built_form": 4, "created_at": "2018-03-05 15:34:51.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17505}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 9 Heron House", "address_line_2": "Church Grove", "assessment_type": "RdSAP", "completion_date": "2018-03-05", "inspection_date": "2018-02-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 5.83}, "total_floor_area": 65, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-03-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 334, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.5167, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 252, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "total_floor_area": {"value": 65.41, "quantity": "square metres"}, "party_wall_length": {"value": 10.97, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.59, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 293, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 75, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 199, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 83}, {"sequence": 4, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "1,400", "improvement_type": "O3", "improvement_details": {"improvement_number": 56}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 49, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 82}}], "hot_water_cost_potential": {"value": 82, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1792, "impact_of_cavity_insulation": -1217, "impact_of_solid_wall_insulation": -470, "space_heating_existing_dwelling": 4059}, "energy_consumption_current": 152, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 100, "environmental_impact_current": 76, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100071268143, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B16 9BH", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2018-08-19 18:20:02.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 2", "address_line_2": "11 Carlyle Road", "address_line_3": "Edgbaston", "assessment_type": "RdSAP", "completion_date": "2018-08-19", "inspection_date": "2018-08-03", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.7, "quantity": "metres"}}, "total_floor_area": 20, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-08-19", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 445, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.11, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 245, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 19.8, "quantity": "square metres"}, "party_wall_length": {"value": 4.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.4, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "200mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 335, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 52, "lighting_cost_current": {"value": 19, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 112, "currency": "GBP"}, "hot_water_cost_current": {"value": 289, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 82, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 207, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 68}], "co2_emissions_potential": 1.5, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 21, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 244, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 97}, {"sequence": 2, "typical_saving": {"value": 217, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 83, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 112, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1790, "impact_of_solid_wall_insulation": -403, "space_heating_existing_dwelling": 2080}, "energy_consumption_current": 618, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 454, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 105, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 42108916, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "To unheated space, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 75% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CH45 9LQ", "hot_water": {"description": "From main system, no cylinder thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "WALLASEY", "built_form": 2, "created_at": "2018-02-26 20:53:22.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1390}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, St. Georges Mount", "assessment_type": "RdSAP", "completion_date": "2018-02-26", "inspection_date": "2018-02-22", "extensions_count": 3, "measurement_type": 2, "total_floor_area": 204, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "true", "registration_date": "2018-02-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 42.62, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.59, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.66, "quantity": "square metres"}, "party_wall_length": {"value": 9.09, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.23, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.61, "quantity": "metres"}, "total_floor_area": {"value": 69.66, "quantity": "square metres"}, "party_wall_length": {"value": 9.09, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.28, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 4.05, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.07, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 2, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.49, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.54, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 15.81, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 2112, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 13, "energy_rating_average": 60, "energy_rating_current": 43, "lighting_cost_current": {"value": 125, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 908, "currency": "GBP"}, "hot_water_cost_current": {"value": 267, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 512, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 44}, {"sequence": 2, "typical_saving": {"value": 247, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 131, "currency": "GBP"}, "indicative_cost": 400, "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 57}, {"sequence": 5, "typical_saving": {"value": 341, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 68}, {"sequence": 6, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 69}, {"sequence": 7, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 74}], "co2_emissions_potential": 4.2, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 125, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 140, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 415, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3824, "impact_of_loft_insulation": -1715, "impact_of_solid_wall_insulation": -3428, "space_heating_existing_dwelling": 30509}, "energy_consumption_current": 353, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 116, "environmental_impact_current": 34, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 74, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 62, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100100099756, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CF5 4JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 2, "created_at": "2018-06-26 19:15:52.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15707}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "121, Wilson Road", "assessment_type": "RdSAP", "completion_date": "2018-06-26", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 72, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-06-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.86, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 35.8, "quantity": "square metres"}, "party_wall_length": {"value": 6.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 599, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 499, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a340", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 4, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 63}, {"sequence": 5, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 6, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 77}], "co2_emissions_potential": 1.6, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2021, "impact_of_loft_insulation": -2868, "space_heating_existing_dwelling": 10146}, "energy_consumption_current": 280, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 126, "environmental_impact_current": 55, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 49, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100120399236, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Mostly double glazing", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 67% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "GL50 4AQ", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CHELTENHAM", "built_form": 4, "created_at": "2018-06-04 18:16:36.000000", "door_count": 3, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "14, St. Pauls Street North", "assessment_type": "RdSAP", "completion_date": "2018-06-04", "inspection_date": "2018-06-04", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 92, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-06-04", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.56, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.37, "quantity": "square metres"}, "party_wall_length": {"value": 15.86, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 43.37, "quantity": "square metres"}, "party_wall_length": {"value": 15.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.51, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.86, "quantity": "square metres"}, "party_wall_length": {"value": 3.36, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.71, "quantity": "metres"}, "total_floor_area": {"value": 7.86, "quantity": "square metres"}, "party_wall_length": {"value": 3.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 632, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 459, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.5, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2210, "impact_of_loft_insulation": -839, "impact_of_solid_wall_insulation": -3192, "space_heating_existing_dwelling": 10696}, "energy_consumption_current": 227, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 85, "calculation_software_version": "3.05r03", "energy_consumption_potential": 92, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10006506466, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "NG34 9FS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SLEAFORD", "built_form": 1, "created_at": "2018-04-26 07:46:29.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17558}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "7, Haverholme Close", "address_line_2": "Ruskington", "assessment_type": "RdSAP", "completion_date": "2018-04-26", "inspection_date": "2018-04-25", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 103, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 103.48, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 42.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 611, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.6, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 116, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 533, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 62, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2077, "space_heating_existing_dwelling": 11163}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 104, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100031588231, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG2 4HY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-07-12 11:40:57.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 102, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "118, Rossington Road", "assessment_type": "RdSAP", "completion_date": "2018-07-12", "inspection_date": "2018-06-02", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 61, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 14.2, "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 30.6, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 16.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 30.6, "quantity": "square metres"}, "party_wall_length": {"value": 6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 534, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 45, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 339, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 140, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 5, "typical_saving": {"value": 283, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 63, "environmental_impact_rating": 58}}], "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2630, "impact_of_loft_insulation": -166, "impact_of_cavity_insulation": -444, "impact_of_solid_wall_insulation": -2878, "space_heating_existing_dwelling": 8531}, "energy_consumption_current": 297, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 84, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 28002218, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 50% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NN11 3AN", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAVENTRY", "built_form": 1, "created_at": "2018-11-06 20:00:23.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "Wayside Bungalow", "address_line_2": "Main Street", "address_line_3": "Badby", "assessment_type": "RdSAP", "completion_date": "2018-11-06", "inspection_date": "2018-11-05", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-11-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 60.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 33.2, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 463, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 406, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 61, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1949, "space_heating_existing_dwelling": 7942}, "energy_consumption_current": 254, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 110, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100120423989, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "GL7 1AU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CIRENCESTER", "built_form": 2, "created_at": "2018-09-05 12:12:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9716}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "2, The Green", "assessment_type": "RdSAP", "completion_date": "2018-09-05", "inspection_date": "2018-09-04", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 94, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-09-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.82, "quantity": "square metres"}, "party_wall_length": {"value": 6.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 21.33, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.29, "quantity": "metres"}, "total_floor_area": {"value": 46.82, "quantity": "square metres"}, "party_wall_length": {"value": 6.91, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.33, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 636, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 600, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 67}, {"sequence": 3, "typical_saving": {"value": 308, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2207, "impact_of_loft_insulation": -2720, "space_heating_existing_dwelling": 11860}, "energy_consumption_current": 224, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 140, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 22, "current_energy_efficiency_band": "D", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 22} +{"uprn": 100040331483, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TQ12 4HH", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NEWTON ABBOT", "built_form": 4, "created_at": "2018-02-15 13:46:56.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "30, Raleigh Road", "assessment_type": "RdSAP", "completion_date": "2018-02-15", "inspection_date": "2018-02-14", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 72, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-02-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 62.47, "quantity": "square metres"}, "party_wall_length": {"value": 13.76, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 360, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 8, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.53, "quantity": "square metres"}, "party_wall_length": {"value": 2.1, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 377, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 340, "currency": "GBP"}, "hot_water_cost_current": {"value": 97, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.0, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 97, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2191, "space_heating_existing_dwelling": 5915}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 158, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 90148780, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 13% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "B62 0BL", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "HALESOWEN", "built_form": 4, "created_at": "2018-07-06 06:54:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2401, "main_heating_category": 7, "main_heating_fraction": 1, "sap_main_heating_code": 402, "main_heating_data_source": 2}], "immersion_heating_type": 1, "secondary_heating_type": 691, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Electric storage heaters", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 8 Pegasus Court", "address_line_2": "Spies Lane", "assessment_type": "RdSAP", "completion_date": "2018-07-06", "inspection_date": "2018-07-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 47, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.4, "quantity": "square metres"}, "party_wall_length": {"value": 19.71, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 8.33, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 13, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 243, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": "Manual charge control", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 202, "currency": "GBP"}, "hot_water_cost_current": {"value": 151, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "L2", "improvement_details": {"improvement_number": 60}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": 725, "improvement_type": "Y", "improvement_details": {"improvement_number": 49}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.0, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 100, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 81, "environmental_impact_rating": 84}], "hot_water_cost_potential": {"value": 128, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1650, "space_heating_existing_dwelling": 2506}, "energy_consumption_current": 299, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 250, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10023549569, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Timber frame, with additional insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 83% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF24 4BH", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "CARDIFF", "built_form": 2, "created_at": "2018-04-25 17:25:07.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "8 Vulcan Court", "address_line_2": "2, Wyeverne Road", "assessment_type": "RdSAP", "completion_date": "2018-04-25", "inspection_date": "2018-04-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 1.5, "quantity": "metres"}}, "total_floor_area": 41, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-04-25", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 5, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.6, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 5, "wall_insulation_type": 3, "wall_thickness_measured": "Y", "wall_insulation_thickness": "100mm"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 40.66, "quantity": "square metres"}, "party_wall_length": {"value": 3.98, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.82, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 83, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 390, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 58, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 210, "currency": "GBP"}, "hot_water_cost_current": {"value": 242, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "\u00a31,200 - \u00a31,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 60}], "co2_emissions_potential": 2.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 366, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 318, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "hot_water_cost_potential": {"value": 124, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1503, "impact_of_loft_insulation": -392, "space_heating_existing_dwelling": 2419}, "energy_consumption_current": 313, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 330, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 6, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 60, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 53, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100110019406, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TS26 0XB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HARTLEPOOL", "built_form": 4, "created_at": "2018-07-05 09:30:52.000000", "door_count": 2, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16687}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "12, Lynmouth Walk", "assessment_type": "RdSAP", "completion_date": "2018-07-05", "inspection_date": "2018-06-26", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 106, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 53.2, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 53.2, "quantity": "square metres"}, "party_wall_length": {"value": 15.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 506, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 91, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 506, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 91, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 56, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1939, "space_heating_existing_dwelling": 8939}, "energy_consumption_current": 160, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 99, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100020409816, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 62% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BR1 3HL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BROMLEY", "built_form": 4, "created_at": "2018-07-08 09:47:23.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "4, Park Place", "address_line_2": "Park Road", "assessment_type": "RdSAP", "completion_date": "2018-07-08", "inspection_date": "2018-06-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.16, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.56, "quantity": "square metres"}, "party_wall_length": {"value": 16.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 31.13, "quantity": "square metres"}, "party_wall_length": {"value": 17.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}, {"floor": 2, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 31.13, "quantity": "square metres"}, "party_wall_length": {"value": 17.06, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 62, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 550, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 88, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 460, "currency": "GBP"}, "hot_water_cost_current": {"value": 164, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 113, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 63, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 136, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2880, "impact_of_loft_insulation": -1860, "space_heating_existing_dwelling": 8322}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 97, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100080130575, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 14% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "LU3 1SP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LUTON", "built_form": 3, "created_at": "2018-03-23 07:21:37.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 1849}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "138, Blundell Road", "assessment_type": "RdSAP", "completion_date": "2018-03-23", "inspection_date": "2018-03-17", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 87, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.64, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.76, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.44, "quantity": "metres"}, "total_floor_area": {"value": 48.24, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 714, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.6, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 111, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 377, "currency": "GBP"}, "hot_water_cost_current": {"value": 166, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 257, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 61, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 78}, {"sequence": 7, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 39, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 54, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 72, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3080, "impact_of_solid_wall_insulation": -5079, "space_heating_existing_dwelling": 11784}, "energy_consumption_current": 297, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 71, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10008638209, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": "ND", "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HU3 2SA", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HULL", "built_form": 4, "created_at": "2018-09-03 10:11:53.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17476}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "339 Anlaby Road", "assessment_type": "RdSAP", "completion_date": "2018-09-03", "inspection_date": "2018-08-30", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 57, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-09-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.04, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.85, "quantity": "square metres"}, "party_wall_length": {"value": 19.44, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.05, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 349, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 260, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1910, "impact_of_solid_wall_insulation": -1382, "space_heating_existing_dwelling": 5357}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 151, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200002752742, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, limited insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 25% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CO10 2PL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SUDBURY", "built_form": 2, "created_at": "2018-01-29 10:38:15.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 1, "main_heating_data_source": 1, "main_heating_index_number": 2039}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "38, Betty Cocker Grove", "assessment_type": "RdSAP", "completion_date": "2018-01-29", "inspection_date": "2018-01-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.38, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 19, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.38, "quantity": "metres"}, "total_floor_area": {"value": 35.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 25, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 444, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 411, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": 45, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 301, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.3, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 35, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 68}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2607, "impact_of_loft_insulation": -244, "space_heating_existing_dwelling": 6393}, "energy_consumption_current": 229, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 94, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100090921215, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Partial double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 55% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NR3 2SB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NORWICH", "built_form": 3, "created_at": "2018-09-13 17:52:49.000000", "door_count": 2, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "105, Rye Avenue", "assessment_type": "RdSAP", "completion_date": "2018-09-13", "inspection_date": "2018-09-13", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 78, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-09-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.35, "quantity": "square metres"}, "party_wall_length": {"value": 4.55, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 14.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.48, "quantity": "metres"}, "total_floor_area": {"value": 36.87, "quantity": "square metres"}, "party_wall_length": {"value": 4.55, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21.45, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.68, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 0, "heat_loss_perimeter": {"value": 7.35, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 55, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 818, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 822, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 55}, {"sequence": 3, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}], "co2_emissions_potential": 3.1, "energy_rating_potential": 69, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2241, "impact_of_loft_insulation": -3707, "space_heating_existing_dwelling": 12537}, "energy_consumption_current": 311, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 75, "calculation_software_version": "2.0.x", "energy_consumption_potential": 222, "environmental_impact_current": 53, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "D", "environmental_impact_potential": 65, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 54, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 25091779, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "MK14 7BD", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MILTON KEYNES", "built_form": 4, "created_at": "2018-02-01 11:05:35.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2304, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "97c, Ramsons Avenue", "address_line_2": "Conniburrow", "assessment_type": "RdSAP", "completion_date": "2018-02-01", "inspection_date": "2018-02-01", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 1}, "total_floor_area": 40, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-01", "sap_energy_source": {"mains_gas": "N", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 2.32, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 39.93, "quantity": "square metres"}, "party_wall_length": {"value": 11.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 184, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, programmer and room thermostat", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 138, "currency": "GBP"}, "hot_water_cost_current": {"value": 104, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 83}, {"sequence": 2, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 104, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1842, "impact_of_cavity_insulation": -860, "space_heating_existing_dwelling": 1711}, "energy_consumption_current": 186, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.03r05", "energy_consumption_potential": 139, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100060696904, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 20% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SO15 1JP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2018-05-26 09:13:05.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10242}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "21, Elgin Road", "assessment_type": "RdSAP", "completion_date": "2018-05-26", "inspection_date": "2018-05-25", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 79, "transaction_type": 1, "conservatory_type": 4, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-26", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"floor_area": {"value": 7.77, "quantity": "square metres"}, "room_height": 1, "double_glazed": "Y", "glazed_perimeter": {"value": 7.77, "quantity": "metres"}}, {"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 27.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.25, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.9, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.34, "quantity": "metres"}, "total_floor_area": {"value": 8.25, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 20, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 774, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 51, "lighting_cost_current": {"value": 100, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 628, "currency": "GBP"}, "hot_water_cost_current": {"value": 99, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 120, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 50}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 40, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 312, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 64}], "co2_emissions_potential": 2.4, "energy_rating_potential": 72, "lighting_cost_potential": {"value": 55, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2199, "impact_of_loft_insulation": -1996, "impact_of_solid_wall_insulation": -2042, "space_heating_existing_dwelling": 10978}, "energy_consumption_current": 322, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 167, "environmental_impact_current": 44, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "E", "environmental_impact_potential": 64, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 49048044, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 43% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "SA43 2JP", "hot_water": {"description": {"value": "Electric immersion, standard tariff, plus solar", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 3}, "post_town": "CARDIGAN", "built_form": 4, "created_at": "2018-03-27 21:17:32", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 18, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 27, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9570}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, LPG", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Brynwern Cottage, Plas-y-Wern", "address_line_2": "Tresaith", "address_line_3": "Tanygroes", "assessment_type": "RdSAP", "completion_date": "2018-03-27", "inspection_date": "2018-03-26", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 69, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-03-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [10], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 350, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.39, "quantity": "square metres"}, "party_wall_length": {"value": 9.96, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 13.56, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.14, "quantity": "metres"}, "total_floor_area": {"value": 30.61, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 18.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 490, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 1, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.07, "quantity": "metres"}, "total_floor_area": {"value": 9.2, "quantity": "square metres"}, "party_wall_length": {"value": 4.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.43, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 43, "solar_water_heating": "Y", "habitable_room_count": 5, "heating_cost_current": {"value": 1045, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.4, "energy_rating_average": 60, "energy_rating_current": 28, "lighting_cost_current": {"value": 78, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 458, "currency": "GBP"}, "hot_water_cost_current": {"value": 165, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 473, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 54, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 117, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": "\u00a31,000", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 306, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 86}, {"sequence": 7, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 99, "environmental_impact_rating": 108}], "co2_emissions_potential": -0.9, "energy_rating_potential": 99, "lighting_cost_potential": {"value": 50, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 267, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 218, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "hot_water_cost_potential": {"value": 107, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2022, "impact_of_loft_insulation": -710, "impact_of_solid_wall_insulation": -5993, "space_heating_existing_dwelling": 11696}, "energy_consumption_current": 303, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": -109, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "F", "environmental_impact_potential": 108, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 63, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100040450973, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Timber frame, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PL1 2QB", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PLYMOUTH", "built_form": 4, "created_at": "2018-07-22 01:03:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Second Floor Flat", "address_line_2": "10 Holyrood Place", "assessment_type": "RdSAP", "completion_date": "2018-07-22", "inspection_date": "2018-07-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 3, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 5.6, "quantity": "metres"}}, "total_floor_area": 43, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-07-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 17.36, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3.1, "quantity": "metres"}, "total_floor_area": {"value": 43.36, "quantity": "square metres"}, "party_wall_length": {"value": 14.29, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.85, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 318, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 240, "currency": "GBP"}, "hot_water_cost_current": {"value": 68, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 79, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.3, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1529, "impact_of_solid_wall_insulation": -1579, "space_heating_existing_dwelling": 3973}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 166, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100054684, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Roof room(s), ceiling insulated", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "CF23 9EY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 2, "created_at": "2018-07-17 12:49:11.000000", "door_count": 3, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16212}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "19, Oakwood Avenue", "address_line_2": "Penylan", "assessment_type": "RdSAP", "completion_date": "2018-07-17", "inspection_date": "2018-07-17", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 33.03, "insulation": 2, "roof_room_connected": "N", "construction_age_band": "D", "roof_insulation_thickness": "150mm"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.03, "quantity": "square metres"}, "party_wall_length": {"value": 6.69, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.63, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 18.15, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.29, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 672, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 120, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 402, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 57}, {"sequence": 2, "typical_saving": {"value": 181, "currency": "GBP"}, "indicative_cost": "2,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 53, "currency": "GBP"}, "indicative_cost": 50, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 321, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2112, "space_heating_existing_dwelling": 12736}, "energy_consumption_current": 272, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 76, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 48, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100031315130, "roofs": [{"description": {"value": "Pitched, 270 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 93% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NG16 1EZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "NOTTINGHAM", "built_form": 2, "created_at": "2018-04-06 08:28:07.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1852}], "immersion_heating_type": "NA", "secondary_heating_type": 604, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "6, Elm Avenue", "address_line_2": "Nuthall", "assessment_type": "RdSAP", "completion_date": "2018-04-06", "inspection_date": "2018-04-06", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 95, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-06", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 40, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 21, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "270mm"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.3, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": 0, "wall_insulation_thickness": "NI"}], "low_energy_lighting": 93, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1080, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.4, "energy_rating_average": 60, "energy_rating_current": 50, "lighting_cost_current": {"value": 69, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 622, "currency": "GBP"}, "hot_water_cost_current": {"value": 173, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 133, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 55, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 81, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 155, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 57}, {"sequence": 4, "typical_saving": {"value": 147, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 6, "typical_saving": {"value": 277, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 76}], "co2_emissions_potential": 2.5, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 206, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2751, "impact_of_loft_insulation": -1513, "impact_of_solid_wall_insulation": -2361, "space_heating_existing_dwelling": 16140}, "energy_consumption_current": 382, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 149, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 14, "current_energy_efficiency_band": "E", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100071092707, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "WS1 2AE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WALSALL", "built_form": 2, "created_at": "2018-05-15 12:50:24.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8077}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "15, Warewell Close", "assessment_type": "RdSAP", "completion_date": "2018-05-15", "inspection_date": "2018-05-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 8.85}, "total_floor_area": 72, "transaction_type": 13, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-05-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 460, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 21.417, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 120, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 72.47, "quantity": "square metres"}, "party_wall_length": {"value": 9.07, "quantity": "metres"}, "heat_loss_perimeter": {"value": 28.61, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "100mm"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 292, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 93, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 233, "currency": "GBP"}, "hot_water_cost_current": {"value": 111, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}, {"sequence": 2, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2031, "impact_of_solid_wall_insulation": -827, "space_heating_existing_dwelling": 3320}, "energy_consumption_current": 153, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 112, "environmental_impact_current": 77, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100070693490, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 71% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV4 7HB", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "COVENTRY", "built_form": 1, "created_at": "2018-05-23 15:54:25.000000", "door_count": 2, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17560}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "4, Riverford Croft", "assessment_type": "RdSAP", "completion_date": "2018-05-23", "inspection_date": "2018-05-23", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 136, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 6, "registration_date": "2018-05-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 27.63, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.42, "quantity": "metres"}, "total_floor_area": {"value": 72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 34.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.57, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.03, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 71, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 834, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 730, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 65}, {"sequence": 2, "typical_saving": {"value": 73, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 285, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 75}], "co2_emissions_potential": 3.3, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 79, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 98, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2165, "impact_of_loft_insulation": -796, "space_heating_existing_dwelling": 14355}, "energy_consumption_current": 201, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 135, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 21, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 15} +{"uprn": 100022792512, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "W9 3BD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-30 09:51:39.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Basement flat", "language": "1"}, "language_code": 1, "property_type": 3, "address_line_1": "40a, Portnall Road", "assessment_type": "RdSAP", "completion_date": "2018-11-30", "inspection_date": "2018-11-29", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 0, "top_storey": "N", "flat_location": -1, "heat_loss_corridor": 0}, "total_floor_area": 95, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-11-30", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 390, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 36.19, "quantity": "square metres"}, "party_wall_length": {"value": 15.4, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 3, "quantity": "metres"}, "total_floor_area": {"value": 36.19, "quantity": "square metres"}, "party_wall_length": {"value": 15.4, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.2, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 11.31, "quantity": "square metres"}, "party_wall_length": {"value": 3.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 11.31, "quantity": "square metres"}, "party_wall_length": {"value": 3.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 499, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 95, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 296, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 80, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 150, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a320", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 54, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.9, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 105, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2449, "impact_of_solid_wall_insulation": -3421, "space_heating_existing_dwelling": 8782}, "energy_consumption_current": 183, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 32, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100071274152, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 40% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "B7 4QF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2018-11-09 08:18:55.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 58 Home Tower", "address_line_2": "Duddeston Manor Road", "assessment_type": "RdSAP", "completion_date": "2018-11-09", "inspection_date": "2018-11-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 8, "heat_loss_corridor": 2, "unheated_corridor_length": 13.92}, "total_floor_area": 77, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-09", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 380, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 32.4336, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 250, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 76.62, "quantity": "square metres"}, "party_wall_length": {"value": 1.91, "quantity": "metres"}, "heat_loss_perimeter": {"value": 37.36, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 380, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 287, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.8, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 37, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 78}}], "hot_water_cost_potential": {"value": 99, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2109, "impact_of_cavity_insulation": -1032, "impact_of_solid_wall_insulation": -1171, "space_heating_existing_dwelling": 6042}, "energy_consumption_current": 176, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 131, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 121037249, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 89% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SW16 6RE", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-09-12 09:29:58.000000", "door_count": 1, "glazed_area": 2, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10244}], "immersion_heating_type": "NA", "secondary_heating_type": 612, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "38b, Penwortham Road", "assessment_type": "RdSAP", "completion_date": "2018-09-12", "inspection_date": "2018-09-11", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 63, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-09-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.32, "quantity": "square metres"}, "party_wall_length": {"value": 20.78, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 12.96, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.1, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 7.66, "quantity": "square metres"}, "party_wall_length": {"value": 2.18, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.69, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 89, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 374, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 274, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}], "co2_emissions_potential": 1.6, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2100, "impact_of_solid_wall_insulation": -1062, "space_heating_existing_dwelling": 4402}, "energy_consumption_current": 196, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 147, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 76, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100060755147, "roofs": [{"description": "Pitched, 350 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "PO30 2AF", "hot_water": {"description": "Electric instantaneous at point of use", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "NEWPORT", "built_form": 2, "created_at": "2018-09-18 21:21:04.000000", "door_count": 2, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Room heaters, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Semi-detached bungalow", "language_code": 1, "property_type": 1, "address_line_1": "45, Furrlongs", "assessment_type": "RdSAP", "completion_date": "2018-09-18", "inspection_date": "2018-09-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 56, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-09-18", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55.88, "quantity": "square metres"}, "party_wall_length": {"value": 9.44, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "350mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1079, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.1, "energy_rating_average": 60, "energy_rating_current": 33, "lighting_cost_current": {"value": 42, "currency": "GBP"}, "main_heating_controls": [{"description": "Appliance thermostats", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 446, "currency": "GBP"}, "hot_water_cost_current": {"value": 183, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 141, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 47}, {"sequence": 2, "typical_saving": {"value": 149, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 52}, {"sequence": 3, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 62}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 50}, {"sequence": 4, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 54}, {"sequence": 5, "typical_saving": {"value": 362, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 66}], "co2_emissions_potential": 1.9, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 47, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 119, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 45, "environmental_impact_rating": 51}, {"sequence": 2, "typical_saving": {"value": 495, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 70, "environmental_impact_rating": 91}, {"sequence": 3, "typical_saving": {"value": 454, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 71, "environmental_impact_rating": 74}], "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1104, "impact_of_cavity_insulation": -854, "space_heating_existing_dwelling": 6520}, "energy_consumption_current": 433, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.07r02", "energy_consumption_potential": 199, "environmental_impact_current": 42, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 66, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 73, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 63016896, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "WF8 2TR", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTEFRACT", "built_form": 1, "created_at": "2018-02-12 16:39:18.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2309, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "1 Camelot Court", "address_line_2": "Viking Road", "assessment_type": "RdSAP", "completion_date": "2018-02-12", "inspection_date": "2018-02-12", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 8.5}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-12", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.805, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.72, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 0, "heat_loss_perimeter": {"value": 32.8, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 511, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.9, "energy_rating_average": 60, "energy_rating_current": 65, "lighting_cost_current": {"value": 43, "currency": "GBP"}, "main_heating_controls": [{"description": "Charging system linked to use of community heating, programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 490, "currency": "GBP"}, "hot_water_cost_current": {"value": 106, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 63}], "co2_emissions_potential": 2.8, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 71, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 68}}], "hot_water_cost_potential": {"value": 106, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1971, "impact_of_cavity_insulation": -316, "space_heating_existing_dwelling": 6339}, "energy_consumption_current": 284, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 273, "environmental_impact_current": 62, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 63, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100070292671, "roofs": [{"description": {"value": "Pitched, 150 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B25 8PW", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIRMINGHAM", "built_form": 4, "created_at": "2018-02-15 08:24:04.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 80}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "No system present: electric heaters assumed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "117, Berkeley Road East", "assessment_type": "RdSAP", "completion_date": "2018-02-15", "inspection_date": "2018-02-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 71, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 0, "pvc_window_frames": "true", "registration_date": "2018-02-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.42, "quantity": "square metres"}, "party_wall_length": {"value": 7.1, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 17.05, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 36.56, "quantity": "square metres"}, "party_wall_length": {"value": 14.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1605, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 19, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 357, "currency": "GBP"}, "hot_water_cost_current": {"value": 440, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 510, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 42}, {"sequence": 2, "typical_saving": {"value": 152, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 39, "environmental_impact_rating": 46}, {"sequence": 3, "typical_saving": {"value": 918, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 1.1, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 62, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 895, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 807, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 904, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 69, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2730, "impact_of_loft_insulation": -218, "impact_of_solid_wall_insulation": -3190, "space_heating_existing_dwelling": 9956}, "energy_consumption_current": 565, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 84, "environmental_impact_current": 31, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "G", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 96, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 10012111839, "roofs": [{"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in 50% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "EX34 8LS", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "ILFRACOMBE", "built_form": 2, "created_at": "2018-02-17 10:14:02.000000", "door_count": 1, "glazed_area": 1, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8190}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Semi-detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Azalea", "address_line_2": "Allenders Farm", "assessment_type": "RdSAP", "completion_date": "2018-02-17", "inspection_date": "2018-02-13", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-02-17", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 41.4, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "A"}, "roof_construction": 5, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.4, "quantity": "square metres"}, "party_wall_length": {"value": 5, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 50, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 840, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 8.2, "energy_rating_average": 60, "energy_rating_current": 25, "lighting_cost_current": {"value": 86, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 202, "currency": "GBP"}, "hot_water_cost_current": {"value": 161, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 331, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 40}, {"sequence": 2, "typical_saving": {"value": 124, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 58, "environmental_impact_rating": 50}, {"sequence": 3, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 4, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 53}, {"sequence": 5, "typical_saving": {"value": 19, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 55}, {"sequence": 6, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 61}, {"sequence": 7, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 8, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 9, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 74}, {"sequence": 10, "typical_saving": {"value": 324, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 84}, {"sequence": 11, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 110, "environmental_impact_rating": 103}], "co2_emissions_potential": -0.7, "energy_rating_potential": 110, "lighting_cost_potential": {"value": 57, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 70, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3360, "impact_of_solid_wall_insulation": -2098, "space_heating_existing_dwelling": 17524}, "energy_consumption_current": 377, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": -101, "environmental_impact_current": 23, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "F", "environmental_impact_potential": 103, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 99, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 34056452, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W14 0RY", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-02-14 21:30:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 94 North End House", "address_line_2": "Fitzjames Avenue", "assessment_type": "RdSAP", "completion_date": "2018-02-14", "inspection_date": "2018-02-10", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 3.144, "quantity": "metres"}}, "total_floor_area": 89, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-02-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 8.243568, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.622, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 88.72, "quantity": "square metres"}, "party_wall_length": {"value": 9.654, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.034, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 543, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 80, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 303, "currency": "GBP"}, "hot_water_cost_current": {"value": 127, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 2, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.1, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 127, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2243, "impact_of_solid_wall_insulation": -3251, "space_heating_existing_dwelling": 8066}, "energy_consumption_current": 226, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 137, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100080797528, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 80% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SG4 9JS", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "HITCHIN", "built_form": 4, "created_at": "2018-07-19 14:52:34.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2504, "main_heating_category": 9, "main_heating_fraction": 1, "sap_main_heating_code": 506, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Warm air, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "16, Eynsford Court", "assessment_type": "RdSAP", "completion_date": "2018-07-19", "inspection_date": "2018-07-19", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 82, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-07-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.05, "quantity": "square metres"}, "party_wall_length": {"value": 16.86, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 9.74, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 41.05, "quantity": "square metres"}, "party_wall_length": {"value": 16.86, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.74, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 80, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 708, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.2, "energy_rating_average": 60, "energy_rating_current": 55, "lighting_cost_current": {"value": 70, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 481, "currency": "GBP"}, "hot_water_cost_current": {"value": 319, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 69, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 86, "currency": "GBP"}, "indicative_cost": "\u00a3300 - \u00a3600", "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 61, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 26, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a31,250 - \u00a32,500", "improvement_type": "M", "improvement_details": {"improvement_number": 26}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 67}, {"sequence": 5, "typical_saving": {"value": 143, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 303, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 80, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.7, "energy_rating_potential": 80, "lighting_cost_potential": {"value": 70, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 355, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 255, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 3, "typical_saving": {"value": 378, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 72}], "hot_water_cost_potential": {"value": 175, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1927, "impact_of_loft_insulation": -1028, "space_heating_existing_dwelling": 8929}, "energy_consumption_current": 296, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 115, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 51, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100020195915, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "No low energy lighting", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "DA5 3AR", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEXLEY", "built_form": 2, "created_at": "2018-04-12 08:52:36", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10328}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "14, Crofton Avenue", "assessment_type": "RdSAP", "completion_date": "2018-04-12", "inspection_date": "2018-04-11", "extensions_count": 4, "measurement_type": 1, "total_floor_area": 108, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 6, "registration_date": "2018-04-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, wood logs", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 26.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 4.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 26.15, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 5.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 10.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 10.35, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 6.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.6, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 12.6, "quantity": "square metres"}, "party_wall_length": {"value": 2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.3, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 4", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 3, "building_part_number": 5, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.6, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.68, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 3.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 534, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 474, "currency": "GBP"}, "hot_water_cost_current": {"value": 107, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 59, "currency": "GBP"}, "indicative_cost": "\u00a390", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 35, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}, {"sequence": 5, "typical_saving": {"value": 296, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 69, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2269, "impact_of_loft_insulation": -274, "impact_of_solid_wall_insulation": -898, "space_heating_existing_dwelling": 7684}, "energy_consumption_current": 169, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 79, "environmental_impact_current": 72, "fixed_lighting_outlets_count": 18, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 26, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100070112201, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV9 2EL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ATHERSTONE", "built_form": 2, "created_at": "2018-11-13 14:19:34.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17659}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "83, Boot Hill", "address_line_2": "Grendon", "assessment_type": "RdSAP", "completion_date": "2018-11-13", "inspection_date": "2018-11-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 83, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-11-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 41.34, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 41.34, "quantity": "square metres"}, "party_wall_length": {"value": 7.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 618, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 59, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 447, "currency": "GBP"}, "hot_water_cost_current": {"value": 86, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 123, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.5, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 67, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 73}}], "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1932, "impact_of_cavity_insulation": -2797, "space_heating_existing_dwelling": 11434}, "energy_consumption_current": 240, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 99, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 42, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100080719133, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM23 4EA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BISHOP'S STORTFORD", "built_form": 5, "created_at": "2018-02-21 16:00:38.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8406}], "immersion_heating_type": "NA", "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "58, Ashdale", "assessment_type": "RdSAP", "completion_date": "2018-02-21", "inspection_date": "2018-02-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 42, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-02-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 20.72, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 20.72, "quantity": "square metres"}, "party_wall_length": {"value": 5.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 1, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 373, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.5, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 318, "currency": "GBP"}, "hot_water_cost_current": {"value": 179, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 63}, {"sequence": 2, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 66}, {"sequence": 3, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 68}, {"sequence": 4, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 34, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 295, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.6, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 66}], "hot_water_cost_potential": {"value": 59, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3101, "impact_of_loft_insulation": -239, "space_heating_existing_dwelling": 4755}, "energy_consumption_current": 339, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 81, "environmental_impact_current": 61, "fixed_lighting_outlets_count": 13, "current_energy_efficiency_band": "D", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 13} +{"uprn": 100060221062, "roofs": [{"description": "Pitched, 150 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "RG22 6SD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BASINGSTOKE", "built_form": 3, "created_at": "2018-07-23 14:29:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 33, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17430}], "immersion_heating_type": "NA", "secondary_heating_type": 631, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "18, Cleaver Road", "assessment_type": "RdSAP", "completion_date": "2018-07-23", "inspection_date": "2018-07-23", "extensions_count": 0, "measurement_type": 2, "total_floor_area": 86, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-07-23", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "Room heaters, coal", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 49.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.1, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 49.31, "quantity": "square metres"}, "party_wall_length": {"value": 6.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 23.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "150mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 782, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.1, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 87, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 1, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 552, "currency": "GBP"}, "hot_water_cost_current": {"value": 83, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 154, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 56}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 59}, {"sequence": 3, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 60}, {"sequence": 4, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 62}, {"sequence": 5, "typical_saving": {"value": 30, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 64}, {"sequence": 6, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 73}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 84, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 69, "environmental_impact_rating": 61}}], "hot_water_cost_potential": {"value": 53, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1856, "impact_of_loft_insulation": -244, "impact_of_cavity_insulation": -2959, "space_heating_existing_dwelling": 12677}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 119, "environmental_impact_current": 47, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 73, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 60, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 6174, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "System built, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"system_build": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BS10 6BD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 2, "created_at": "2018-04-14 11:43:02.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "299, Greystoke Avenue", "assessment_type": "RdSAP", "completion_date": "2018-04-14", "inspection_date": "2018-04-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 84, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-04-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.48, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.93, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.46, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 41.53, "quantity": "square metres"}, "party_wall_length": {"value": 7.16, "quantity": "metres"}, "heat_loss_perimeter": {"value": 18.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 625, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 63, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 598, "currency": "GBP"}, "hot_water_cost_current": {"value": 105, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 64, "environmental_impact_rating": 59}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 60}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 62}, {"sequence": 4, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 71}], "co2_emissions_potential": 2.3, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2391, "space_heating_existing_dwelling": 11476}, "energy_consumption_current": 249, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 92, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 151, "environmental_impact_current": 57, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 71, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 44, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10006752926, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "HX5 0DN", "hot_water": {"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}, "post_town": "ELLAND", "built_form": 2, "created_at": "2018-12-02 11:00:49.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 901, "water_heating_fuel": 25, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 25, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2305, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 304, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Community scheme", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 5}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "21 Towngate House", "assessment_type": "RdSAP", "completion_date": "2018-12-02", "inspection_date": "2018-11-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 14.4, "quantity": "metres"}}, "total_floor_area": 53, "transaction_type": 12, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-02", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 32.832, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 300, "wall_construction": 4, "wall_insulation_type": 2, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "total_floor_area": {"value": 52.58, "quantity": "square metres"}, "party_wall_length": {"value": 6.1, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 212, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.1, "energy_rating_average": 60, "energy_rating_current": 77, "lighting_cost_current": {"value": 57, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Flat rate charging, programmer and TRVs", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 215, "currency": "GBP"}, "hot_water_cost_current": {"value": 117, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 86}], "co2_emissions_potential": 1.0, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 117, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2111, "space_heating_existing_dwelling": 2262}, "energy_consumption_current": 121, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 116, "environmental_impact_current": 85, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 2.8, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 86, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 20, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100061711245, "roofs": [{"description": {"value": "Roof room(s), no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Some double glazing", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 57% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "PO20 3SU", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 1}, "post_town": "CHICHESTER", "built_form": 1, "created_at": "2018-09-28 15:56:37.000000", "door_count": 2, "glazed_area": 2, "glazing_gap": "16+", "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 0, "water_heating_code": 901, "water_heating_fuel": 33, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 33, "boiler_flue_type": 1, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2101, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 158, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, coal", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 1}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "The Cottage", "address_line_2": "Lidsey Road", "address_line_3": "Woodgate", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-09-28", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 93, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 45.61, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "B"}, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.39, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.15, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 28.62, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 1585, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 17.0, "energy_rating_average": 60, "energy_rating_current": 19, "lighting_cost_current": {"value": 98, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No time or thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 413, "currency": "GBP"}, "hot_water_cost_current": {"value": 421, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 10, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 633, "currency": "GBP"}, "indicative_cost": "\u00a31,500 - \u00a32,700", "improvement_type": "A3", "improvement_details": {"improvement_number": 46}, "improvement_category": 5, "energy_performance_rating": 38, "environmental_impact_rating": 13}, {"sequence": 2, "typical_saving": {"value": 107, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 42, "environmental_impact_rating": 17}, {"sequence": 3, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 46, "environmental_impact_rating": 21}, {"sequence": 4, "typical_saving": {"value": 38, "currency": "GBP"}, "indicative_cost": "\u00a380 - \u00a3120", "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 23}, {"sequence": 5, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "\u00a315", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 48, "environmental_impact_rating": 23}, {"sequence": 6, "typical_saving": {"value": 97, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 11}, "improvement_category": 5, "energy_performance_rating": 52, "environmental_impact_rating": 27}, {"sequence": 7, "typical_saving": {"value": 416, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 67}, {"sequence": 8, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 9, "typical_saving": {"value": 84, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 10, "typical_saving": {"value": 352, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 83}], "co2_emissions_potential": 1.2, "energy_rating_potential": 85, "lighting_cost_potential": {"value": 68, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 55, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 44, "environmental_impact_rating": 19}, {"sequence": 2, "typical_saving": {"value": 186, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 62, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 471, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 72, "environmental_impact_rating": 67}], "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 5764, "impact_of_loft_insulation": -142, "impact_of_cavity_insulation": -1321, "space_heating_existing_dwelling": 22382}, "energy_consumption_current": 537, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 10, "calculation_software_version": "2.0.x", "energy_consumption_potential": 69, "environmental_impact_current": 1, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "G", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 182, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 200000628094, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "No low energy lighting", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "postcode": "HU13 0NY", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HESSLE", "built_form": 1, "created_at": "2018-02-22 17:50:33.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16210}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "48, The Willows", "assessment_type": "RdSAP", "completion_date": "2018-02-22", "inspection_date": "2018-02-22", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 110, "transaction_type": 1, "conservatory_type": 2, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-02-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.32, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 110.13, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 44.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 0, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 597, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 148, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Room thermostat only", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 571, "currency": "GBP"}, "hot_water_cost_current": {"value": 100, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a355", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 291, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 83, "environmental_impact_rating": 80}], "co2_emissions_potential": 2.2, "energy_rating_potential": 83, "lighting_cost_potential": {"value": 74, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 68, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2207, "space_heating_existing_dwelling": 10838}, "energy_consumption_current": 191, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 112, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 11, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 0} +{"uprn": 100050913320, "roofs": [{"description": "Flat, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Timber frame, with additional insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"addendum_numbers": [1]}, "lighting": {"description": "Low energy lighting in 60% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "S8 8EA", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SHEFFIELD", "built_form": 4, "created_at": "2018-04-20 12:30:44.000000", "door_count": 2, "glazed_area": 1, "region_code": 3, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "13, Batemoor Close", "assessment_type": "RdSAP", "completion_date": "2018-04-20", "inspection_date": "2018-04-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 89, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-04-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 190, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 44.49, "quantity": "square metres"}, "party_wall_length": {"value": 13.46, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.22, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.31, "quantity": "metres"}, "total_floor_area": {"value": 44.49, "quantity": "square metres"}, "party_wall_length": {"value": 13.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 13.22, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 602, "currency": "GBP"}, "insulated_door_count": 1, "co2_emissions_current": 3.5, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 85, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 605, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "insulated_door_u_value": 1.2, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 21, "currency": "GBP"}, "indicative_cost": 20, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 266, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.4, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 61, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1931, "space_heating_existing_dwelling": 10988}, "energy_consumption_current": 221, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r02", "energy_consumption_potential": 148, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 100071339378, "roofs": [{"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B37 5EU", "hot_water": {"description": {"value": "Electric immersion, off-peak", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 2}, "post_town": "BIRMINGHAM", "built_form": 3, "created_at": "2018-05-03 15:50:19.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 3, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15502}], "immersion_heating_type": 2, "secondary_heating_type": 691, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 6", "address_line_2": "62, Heathmere Drive", "assessment_type": "RdSAP", "completion_date": "2018-05-03", "inspection_date": "2018-04-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 6, "quantity": "metres"}}, "total_floor_area": 45, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-03", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 6, "roof_construction": 1, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.8, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 230, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 44.75, "quantity": "square metres"}, "party_wall_length": {"value": 2.9, "quantity": "metres"}, "heat_loss_perimeter": {"value": 26.3, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 575, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.7, "energy_rating_average": 60, "energy_rating_current": 48, "lighting_cost_current": {"value": 37, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 322, "currency": "GBP"}, "hot_water_cost_current": {"value": 262, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 157, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 57, "environmental_impact_rating": 55}, {"sequence": 2, "typical_saving": {"value": 85, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 61}, {"sequence": 3, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 68}], "co2_emissions_potential": 2.1, "energy_rating_potential": 67, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 45, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 64, "environmental_impact_rating": 64}}], "hot_water_cost_potential": {"value": 180, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2813, "impact_of_cavity_insulation": -1300, "impact_of_solid_wall_insulation": -400, "space_heating_existing_dwelling": 7610}, "energy_consumption_current": 479, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 272, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 68, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 83, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 100030002014, "roofs": [{"description": {"value": "Pitched, 200 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "DE55 1EG", "hot_water": {"description": {"value": "From main system, no cylinder thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "ALFRETON", "built_form": 1, "created_at": "2018-11-20 19:30:10.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "N", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8872}], "immersion_heating_type": "NA", "secondary_heating_type": 603, "cylinder_insulation_type": 2, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Caernarfon Close", "address_line_2": "Swanwick", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-11-20", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 113, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 6, "pvc_window_frames": "true", "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 57.88, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 25.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 57.88, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 31.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 17.28, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 6, "heating_cost_current": {"value": 587, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 73, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 543, "currency": "GBP"}, "hot_water_cost_current": {"value": 195, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a315 - \u00a330", "improvement_type": "C", "improvement_details": {"improvement_number": 2}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3200 - \u00a3400", "improvement_type": "F", "improvement_details": {"improvement_number": 4}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 44, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 284, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 2.2, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 73, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3922, "space_heating_existing_dwelling": 9813}, "energy_consumption_current": 199, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 109, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 20, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 20} +{"uprn": 10070372265, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 38% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "PR26 9AT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "post_town": "LEYLAND", "built_form": 4, "created_at": "2018-11-20 14:30:30.000000", "door_count": 1, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 28, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 28, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8934}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, oil", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Primrose Cottage", "address_line_2": "Bretherton", "assessment_type": "RdSAP", "completion_date": "2018-11-20", "inspection_date": "2018-11-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 120, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-11-20", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 680, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 30.32, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "J"}, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.44, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.45, "quantity": "square metres"}, "party_wall_length": {"value": 14.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.06, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.53, "quantity": "metres"}, "total_floor_area": {"value": 46.94, "quantity": "square metres"}, "party_wall_length": {"value": 14.74, "quantity": "metres"}, "heat_loss_perimeter": {"value": 12.74, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "J", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "100mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 38, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 344, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 129, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 306, "currency": "GBP"}, "hot_water_cost_current": {"value": 137, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 37, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 279, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 85, "environmental_impact_rating": 80}, {"sequence": 6, "typical_saving": {"value": 592, "currency": "GBP"}, "indicative_cost": "\u00a315,000 - \u00a325,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 102, "environmental_impact_rating": 95}], "co2_emissions_potential": 0.3, "energy_rating_potential": 102, "lighting_cost_potential": {"value": 80, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 73, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2724, "space_heating_existing_dwelling": 6377}, "energy_consumption_current": 133, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": -34, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 95, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10010747217, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Sandstone or limestone, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "S33 6RR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "HOPE VALLEY", "built_form": 2, "created_at": "2018-06-14 16:08:42.000000", "door_count": 1, "glazed_area": 1, "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Gypsies Barn", "address_line_2": "Station Road", "address_line_3": "Hope", "assessment_type": "RdSAP", "completion_date": "2018-06-14", "inspection_date": "2018-06-14", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 48, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-06-14", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 750, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.7, "quantity": "square metres"}, "party_wall_length": {"value": 3.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 28.31, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 301, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 301, "currency": "GBP"}, "hot_water_cost_current": {"value": 84, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.7, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 84, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1664, "space_heating_existing_dwelling": 4041}, "energy_consumption_current": 200, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 200, "environmental_impact_current": 78, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200145703, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Flat, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 17% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NW11 7RL", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-06-15 22:01:08.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16840}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "69 North End Road", "assessment_type": "RdSAP", "completion_date": "2018-06-15", "inspection_date": "2018-06-15", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 1}, "total_floor_area": 59, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-06-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.87, "quantity": "square metres"}, "party_wall_length": {"value": 12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 13.56, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.79, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 17, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 371, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 81, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 280, "currency": "GBP"}, "hot_water_cost_current": {"value": 74, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 63, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 78}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.5, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1628, "impact_of_solid_wall_insulation": -1416, "space_heating_existing_dwelling": 5773}, "energy_consumption_current": 206, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 148, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 22002757, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Mostly double glazing", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 44% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN41 1SW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRIGHTON", "built_form": 4, "created_at": "2018-03-07 21:48:02.000000", "door_count": 2, "glazed_area": 4, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16632}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "sap_windows": [{"pvc_frame": "false", "orientation": 1, "window_area": {"value": 0.45, "quantity": "square metres"}, "window_type": 1, "glazing_type": 5, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 1, "window_area": {"value": 0.82, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 7, "window_area": {"value": 4.27, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": 12, "orientation": 5, "window_area": {"value": 3.46, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 0.47, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 5, "window_area": {"value": 1.21, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "true", "glazing_gap": "16+", "orientation": 5, "window_area": {"value": 2.58, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 1.67, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}, {"pvc_frame": "false", "orientation": 1, "window_area": {"value": 2.43, "quantity": "square metres"}, "window_type": 1, "glazing_type": 3, "window_location": 0}], "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Stanley Road", "address_line_2": "Portslade", "assessment_type": "RdSAP", "completion_date": "2018-03-07", "inspection_date": "2018-03-07", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 66, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-03-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 33.87, "quantity": "square metres"}, "party_wall_length": {"value": 13.12, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.94, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 32.44, "quantity": "square metres"}, "party_wall_length": {"value": 12.6, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 492, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 74, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer and room thermostat", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 415, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 20, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 23, "currency": "GBP"}, "indicative_cost": "\u00a325", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 70}, {"sequence": 4, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 13}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 74}, {"sequence": 6, "typical_saving": {"value": 319, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2013, "impact_of_loft_insulation": -355, "space_heating_existing_dwelling": 6732}, "energy_consumption_current": 228, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 81, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 40, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 10003506804, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EX39 2AN", "hot_water": {"description": {"value": "Electric immersion, standard tariff", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "BIDEFORD", "built_form": 6, "created_at": "2018-03-06 06:21:40.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 15, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2601, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 693, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "54b, High Street", "assessment_type": "RdSAP", "completion_date": "2018-03-06", "inspection_date": "2018-03-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 50, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-03-06", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 50.05, "quantity": "square metres"}, "party_wall_length": {"value": 21.9, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 374, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "No thermostatic control of room temperature", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 292, "currency": "GBP"}, "hot_water_cost_current": {"value": 259, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "\u00a3500", "improvement_type": "X", "improvement_details": {"improvement_number": 48}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 70}], "co2_emissions_potential": 1.9, "energy_rating_potential": 66, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 259, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1608, "impact_of_solid_wall_insulation": -369, "space_heating_existing_dwelling": 2319}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 224, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 3, "current_energy_efficiency_band": "D", "environmental_impact_potential": 70, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 43, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10032898113, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 24% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "GU30 7QT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LIPHOOK", "built_form": 2, "created_at": "2018-08-08 16:31:21.000000", "door_count": 1, "glazed_area": 1, "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10164}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "66, Lark Rise", "assessment_type": "RdSAP", "completion_date": "2018-08-08", "inspection_date": "2018-08-08", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 75, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "registration_date": "2018-08-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.29, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.24, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 17.88, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 37.7, "quantity": "square metres"}, "party_wall_length": {"value": 8.25, "quantity": "metres"}, "heat_loss_perimeter": {"value": 17.87, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": 2, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 24, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 345, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 104, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 325, "currency": "GBP"}, "hot_water_cost_current": {"value": 114, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": 600, "improvement_type": "B4", "improvement_details": {"improvement_number": 63}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 39, "currency": "GBP"}, "indicative_cost": 65, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}, {"sequence": 4, "typical_saving": {"value": 315, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 89, "environmental_impact_rating": 89}], "co2_emissions_potential": 0.8, "energy_rating_potential": 89, "lighting_cost_potential": {"value": 59, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2347, "space_heating_existing_dwelling": 5070}, "energy_consumption_current": 174, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 58, "environmental_impact_current": 73, "fixed_lighting_outlets_count": 17, "current_energy_efficiency_band": "C", "environmental_impact_potential": 89, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 207104671, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, insulated", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "N9 7PT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-01-05 16:20:17.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 103, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 601, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "8, St. Edmunds Road", "assessment_type": "RdSAP", "completion_date": "2018-01-05", "inspection_date": "2018-01-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 42, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-01-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.52, "quantity": "metres"}, "floor_insulation": 2, "total_floor_area": {"value": 41.6, "quantity": "square metres"}, "party_wall_length": {"value": 15.71, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 308, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 32, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, TRVs and bypass", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 222, "currency": "GBP"}, "hot_water_cost_current": {"value": 91, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 2, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.2, "energy_rating_potential": 76, "lighting_cost_potential": {"value": 32, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 75, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1570, "impact_of_solid_wall_insulation": -876, "space_heating_existing_dwelling": 3121}, "energy_consumption_current": 234, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.02r04", "energy_consumption_potential": 161, "environmental_impact_current": 70, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 200003342503, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Single glazed", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "lighting": {"description": {"value": "Low energy lighting in 60% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "YO11 1NF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SCARBOROUGH", "built_form": 4, "created_at": "2018-11-27 17:21:13.000000", "door_count": 1, "glazed_area": 1, "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16637}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "39-40 Newborough", "assessment_type": "RdSAP", "completion_date": "2018-11-27", "inspection_date": "2018-11-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 7.89, "quantity": "metres"}}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-11-27", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 19.4883, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 140, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 57.99, "quantity": "square metres"}, "party_wall_length": {"value": 13.83, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.63, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 60, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 346, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.0, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 62, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 199, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 0, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 93, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}, {"sequence": 2, "typical_saving": {"value": 16, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 82}, {"sequence": 3, "typical_saving": {"value": 55, "currency": "GBP"}, "indicative_cost": "\u00a33,300 - \u00a36,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 85}], "co2_emissions_potential": 1.1, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 45, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1754, "impact_of_solid_wall_insulation": -2120, "space_heating_existing_dwelling": 5281}, "energy_consumption_current": 194, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 110, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 5, "windows_transmission_details": {"u_value": 4.8, "data_source": 2, "solar_transmittance": 0.85}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 34, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100040808003, "roofs": [{"description": "Pitched, 100 mm loft insulation", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Cavity wall, as built, no insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BH14 0HF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "POOLE", "built_form": 1, "created_at": "2018-11-29 17:05:28.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15018}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 12}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Top-floor maisonette", "language_code": 1, "property_type": 3, "address_line_1": "First Floor Flat", "address_line_2": "3, Glen Road", "assessment_type": "RdSAP", "completion_date": "2018-11-29", "inspection_date": "2018-11-29", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 1.4}, "total_floor_area": 66, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-11-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 3.444, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 100, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 66.26, "quantity": "square metres"}, "party_wall_length": {"value": 2.26, "quantity": "metres"}, "heat_loss_perimeter": {"value": 39.16, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 529, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 61, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 367, "currency": "GBP"}, "hot_water_cost_current": {"value": 144, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 63, "environmental_impact_rating": 58}, {"sequence": 2, "typical_saving": {"value": 138, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "C", "improvement_details": {"improvement_number": 3}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}], "co2_emissions_potential": 2.3, "energy_rating_potential": 71, "lighting_cost_potential": {"value": 51, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 76, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 74}}], "hot_water_cost_potential": {"value": 119, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 3066, "impact_of_loft_insulation": -625, "impact_of_cavity_insulation": -2815, "space_heating_existing_dwelling": 8382}, "energy_consumption_current": 283, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 196, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 69, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 10091540648, "roofs": [{"description": "Pitched, insulated at rafters", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Roof room(s), insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SP3 5EL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}, "post_town": "SALISBURY", "built_form": 1, "created_at": "2018-11-27 09:33:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 3, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 3, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16697}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, LPG", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 4}], "dwelling_type": "Detached house", "language_code": 1, "property_type": 0, "address_line_1": "Garden Cottage Penruddocke Arms", "address_line_2": "Hindon Road", "address_line_3": "Dinton", "assessment_type": "RdSAP", "completion_date": "2018-11-27", "inspection_date": "2018-11-27", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 109, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-11-27", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, electric", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": 43.43, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "G"}, "roof_construction": 5, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 42.74, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.77, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 13.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 1, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "rafter_insulation_thickness": "150mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 1234, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 40, "lighting_cost_current": {"value": 72, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 1126, "currency": "GBP"}, "hot_water_cost_current": {"value": 277, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 108, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 44, "environmental_impact_rating": 67}, {"sequence": 2, "typical_saving": {"value": 103, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 47, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 313, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 77}], "co2_emissions_potential": 2.4, "energy_rating_potential": 56, "lighting_cost_potential": {"value": 72, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 175, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2266, "space_heating_existing_dwelling": 9950}, "energy_consumption_current": 171, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 97, "environmental_impact_current": 65, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "E", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 35, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10000800924, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Solid brick, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "MK43 0AP", "hot_water": {"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BEDFORD", "built_form": 3, "created_at": "2018-08-13 15:37:43.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": 12, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 20, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 20, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2307, "main_heating_category": 6, "main_heating_fraction": 1, "sap_main_heating_code": 301, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Community scheme", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "1 Fedden House", "address_line_2": "Wharley End, Cranfield", "assessment_type": "RdSAP", "completion_date": "2018-08-13", "inspection_date": "2018-07-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 5.96}, "total_floor_area": 28, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 1, "pvc_window_frames": "true", "registration_date": "2018-08-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.708, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 130, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 27.9, "quantity": "square metres"}, "party_wall_length": {"value": 5.05, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.97, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 1, "heating_cost_current": {"value": 247, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.5, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 24, "currency": "GBP"}, "main_heating_controls": [{"description": "Flat rate charging, TRVs", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 187, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 15, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 45, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 78}], "co2_emissions_potential": 1.2, "energy_rating_potential": 75, "lighting_cost_potential": {"value": 24, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 92, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1664, "impact_of_solid_wall_insulation": -273, "space_heating_existing_dwelling": 2883}, "energy_consumption_current": 309, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.06r03", "energy_consumption_potential": 239, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 4, "current_energy_efficiency_band": "C", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 55, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 15112606, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 14% of fixed outlets", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "NN1 3QR", "hot_water": {"description": "Electric immersion, off-peak", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "post_town": "NORTHAMPTON", "built_form": 5, "created_at": "2018-05-08 14:22:46.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 191, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": 1, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, electric", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 16", "address_line_2": "78, Cowper Street", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-04-27", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 2, "heat_loss_corridor": 2, "unheated_corridor_length": 4.2}, "total_floor_area": 55, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 220, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.6, "sheltered_wall": "Y", "wall_dry_lined": "Y", "wall_thickness": 220, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 3, "quantity": "metres"}, "total_floor_area": {"value": 55, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.7, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 14, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1529, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.8, "energy_rating_average": 60, "energy_rating_current": 22, "lighting_cost_current": {"value": 79, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 1216, "currency": "GBP"}, "hot_water_cost_current": {"value": 188, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 33, "environmental_impact_rating": 33}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": 30, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 34, "environmental_impact_rating": 34}], "co2_emissions_potential": 5.5, "energy_rating_potential": 34, "lighting_cost_potential": {"value": 43, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 188, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1869, "impact_of_loft_insulation": -4888, "impact_of_solid_wall_insulation": -2781, "space_heating_existing_dwelling": 10620}, "energy_consumption_current": 730, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 595, "environmental_impact_current": 25, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "F", "environmental_impact_potential": 34, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "F", "co2_emissions_current_per_floor_area": 123, "low_energy_fixed_lighting_outlets_count": 1} +{"uprn": 10033556625, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "W1D 3DD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-05-02 18:24:18.000000", "door_count": 0, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 3, "rooms_with_mixer_shower_no_bath": 2, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 2, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10321}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and underfloor heating, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 28", "address_line_2": "10, Richmond Mews", "assessment_type": "RdSAP", "completion_date": "2018-05-02", "inspection_date": "2018-05-02", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 2, "heat_loss_corridor": 1}, "total_floor_area": 191, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "false", "registration_date": "2018-05-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 1}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 450, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.7, "quantity": "metres"}, "total_floor_area": {"value": 191.35, "quantity": "square metres"}, "party_wall_length": {"value": 38.65, "quantity": "metres"}, "heat_loss_perimeter": {"value": 32.02, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "H", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 372, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.6, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 106, "currency": "GBP"}, "main_heating_controls": [{"description": "Room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 372, "currency": "GBP"}, "hot_water_cost_current": {"value": 143, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 2.6, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 106, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 143, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2999, "space_heating_existing_dwelling": 5986}, "energy_consumption_current": 77, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 77, "environmental_impact_current": 83, "fixed_lighting_outlets_count": 11, "current_energy_efficiency_band": "B", "environmental_impact_potential": 83, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 14, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 10033414881, "roofs": [{"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 91% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "TN6 2BT", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CROWBOROUGH", "built_form": 1, "created_at": "2018-05-02 13:54:29", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 6, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8969}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "The Barn Pellings Farm", "address_line_2": "Green Lane", "assessment_type": "RdSAP", "completion_date": "2018-05-02", "inspection_date": "2018-05-01", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 192, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 7, "pvc_window_frames": "false", "registration_date": "2018-05-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, wood logs", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "lzc_energy_sources": [4], "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 41.3, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "I"}, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.17, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 82.63, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 36.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.11, "quantity": "metres"}, "total_floor_area": {"value": 59, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 38.17, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 5, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.35, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 8.86, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.49, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 91, "solar_water_heating": "N", "habitable_room_count": 7, "heating_cost_current": {"value": 980, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 5.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 108, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 869, "currency": "GBP"}, "hot_water_cost_current": {"value": 157, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 69}, {"sequence": 2, "typical_saving": {"value": 91, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 3, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 4, "typical_saving": {"value": 299, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 79}], "co2_emissions_potential": 3.3, "energy_rating_potential": 81, "lighting_cost_potential": {"value": 108, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 220, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 70}}], "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2999, "impact_of_loft_insulation": -237, "space_heating_existing_dwelling": 16526}, "energy_consumption_current": 170, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 110, "environmental_impact_current": 68, "fixed_lighting_outlets_count": 35, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 28, "low_energy_fixed_lighting_outlets_count": 32} +{"uprn": 100000339566, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 57% of fixed outlets", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "NE33 2AY", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTH SHEILDS", "built_form": 1, "created_at": "2018-05-08 08:39:45.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16137}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "116 Guillemot House", "address_line_2": "Lawe Road", "assessment_type": "RdSAP", "completion_date": "2018-05-08", "inspection_date": "2018-05-04", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 6.9}, "total_floor_area": 47, "transaction_type": 5, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 310, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 16.905, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 310, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 46.8, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "heat_loss_perimeter": {"value": 27.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 57, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 249, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 76, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 251, "currency": "GBP"}, "hot_water_cost_current": {"value": 78, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 14, "currency": "GBP"}, "indicative_cost": 15, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.4, "energy_rating_potential": 77, "lighting_cost_potential": {"value": 37, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1720, "space_heating_existing_dwelling": 3043}, "energy_consumption_current": 171, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 166, "environmental_impact_current": 79, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 30, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100010871678, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 67% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "postcode": "BL2 6PJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BOLTON", "built_form": 2, "created_at": "2018-06-19 17:13:21.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9601}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "22, Deepdale Road", "assessment_type": "RdSAP", "completion_date": "2018-06-19", "inspection_date": "2018-06-19", "extensions_count": 1, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 0}, "total_floor_area": 49, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-06-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 43.68, "quantity": "square metres"}, "party_wall_length": {"value": 7.08, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.48, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 2.41, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 3.62, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.43, "quantity": "metres"}, "total_floor_area": {"value": 2.41, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 3.62, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 67, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 322, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.8, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 49, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 324, "currency": "GBP"}, "hot_water_cost_current": {"value": 79, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 11, "currency": "GBP"}, "indicative_cost": "\u00a310", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}], "co2_emissions_potential": 1.8, "energy_rating_potential": 74, "lighting_cost_potential": {"value": 36, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1677, "space_heating_existing_dwelling": 4665}, "energy_consumption_current": 210, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": 9.93, "energy_consumption_potential": 206, "environmental_impact_current": 75, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "C", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 207128631, "roofs": [{"description": {"value": "Pitched, no insulation", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Flat, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "EN3 6LQ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "ENFIELD", "built_form": 2, "created_at": "2018-03-08 09:54:00.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 1, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17815}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "19, Vian Avenue", "assessment_type": "RdSAP", "completion_date": "2018-03-08", "inspection_date": "2018-03-08", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 76, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "false", "registration_date": "2018-03-08", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.72, "quantity": "square metres"}, "party_wall_length": {"value": 7.7, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 11.98, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 30.82, "quantity": "square metres"}, "party_wall_length": {"value": 7.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.76, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 5, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "wall_thickness": 240, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.34, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 12.08, "quantity": "square metres"}, "party_wall_length": {"value": 3.08, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 6.54, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 801, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 54, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, no room thermostat", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 338, "currency": "GBP"}, "hot_water_cost_current": {"value": 96, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 121, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 59, "environmental_impact_rating": 53}, {"sequence": 2, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "\u00a3850 - \u00a31,500", "improvement_type": "A2", "improvement_details": {"improvement_number": 45}, "improvement_category": 5, "energy_performance_rating": 62, "environmental_impact_rating": 56}, {"sequence": 3, "typical_saving": {"value": 196, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 36, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 5, "typical_saving": {"value": 60, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 6, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 77}, {"sequence": 7, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 65, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2066, "impact_of_loft_insulation": -2557, "impact_of_solid_wall_insulation": -3969, "space_heating_existing_dwelling": 14423}, "energy_consumption_current": 334, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 62, "environmental_impact_current": 46, "fixed_lighting_outlets_count": 10, "windows_transmission_details": {"u_value": 3.1, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "E", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 59, "low_energy_fixed_lighting_outlets_count": 10} +{"uprn": 10010717783, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SK13 8EF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GLOSSOP", "built_form": 4, "created_at": "2018-03-13 07:12:05.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10539}], "immersion_heating_type": "NA", "secondary_heating_type": 605, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "1, Chadwick Street", "assessment_type": "RdSAP", "completion_date": "2018-03-13", "inspection_date": "2018-03-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 60, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-03-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 1, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "Room heaters, mains gas", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 480, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.65, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 29.79, "quantity": "square metres"}, "party_wall_length": {"value": 14.64, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 8.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.88, "quantity": "metres"}, "total_floor_area": {"value": 29.79, "quantity": "square metres"}, "party_wall_length": {"value": 14.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 727, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.0, "energy_rating_average": 60, "energy_rating_current": 60, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 611, "currency": "GBP"}, "hot_water_cost_current": {"value": 89, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 64}, {"sequence": 3, "typical_saving": {"value": 276, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 79, "environmental_impact_rating": 75}], "co2_emissions_potential": 2.4, "energy_rating_potential": 79, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 60, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1853, "impact_of_loft_insulation": -2865, "impact_of_solid_wall_insulation": -2480, "space_heating_existing_dwelling": 11932}, "energy_consumption_current": 380, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 220, "environmental_impact_current": 54, "fixed_lighting_outlets_count": 6, "current_energy_efficiency_band": "D", "environmental_impact_potential": 75, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 67, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 207142751, "roofs": [{"description": {"value": "Pitched, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Roof room(s), insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 33% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "EN4 0BD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BARNET", "built_form": 2, "created_at": "2018-01-12 14:04:25.000000", "door_count": 3, "glazed_area": 2, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 2}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2107, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8638}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "Greystones", "address_line_2": "Westpole Avenue", "address_line_3": "Cockfosters", "assessment_type": "RdSAP", "completion_date": "2018-01-12", "inspection_date": "2018-01-12", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 181, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 8, "pvc_window_frames": "true", "registration_date": "2018-01-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 260, "floor_heat_loss": 7, "sap_room_in_roof": {"floor_area": {"value": 37.04, "quantity": "square metres"}, "insulation": "AB", "roof_room_connected": "N", "construction_age_band": "I"}, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 56.68, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 56.68, "quantity": "square metres"}, "party_wall_length": {"value": 8.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.41, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.8, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 15, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.47, "quantity": "metres"}, "total_floor_area": {"value": 14, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 10.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 33, "solar_water_heating": "N", "habitable_room_count": 8, "heating_cost_current": {"value": 1091, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 6.7, "energy_rating_average": 60, "energy_rating_current": 64, "lighting_cost_current": {"value": 150, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, TRVs and bypass", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 780, "currency": "GBP"}, "hot_water_cost_current": {"value": 172, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 112, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 62}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "\u00a350", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 63}, {"sequence": 4, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "\u00a3350 - \u00a3450", "improvement_type": "G", "improvement_details": {"improvement_number": 14}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 65}, {"sequence": 5, "typical_saving": {"value": 118, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 70}, {"sequence": 6, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 71}, {"sequence": 7, "typical_saving": {"value": 292, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 77}], "co2_emissions_potential": 3.4, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 90, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 184, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 78, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2994, "impact_of_loft_insulation": -1784, "impact_of_solid_wall_insulation": -2155, "space_heating_existing_dwelling": 17908}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 106, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 15, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "D", "environmental_impact_potential": 77, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": null, "roofs": [{"description": {"value": "Pitched, insulated", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Solid brick, with internal insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE9 4QR", "hot_water": {"description": {"value": "Electric instantaneous at point of use", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "LONDON", "built_form": 5, "created_at": "2018-05-02 15:08:47.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 909, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 29, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 0, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2602, "main_heating_category": 10, "main_heating_fraction": 1, "sap_main_heating_code": 691, "mcs_installed_heat_pump": "false", "main_heating_data_source": 2}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "", "country_code": "EAW", "main_heating": [{"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 1a", "address_line_2": "38b Mottingham Road", "assessment_type": "RdSAP", "completion_date": "2018-05-02", "inspection_date": "2018-01-26", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-02", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 370, "floor_heat_loss": 7, "roof_construction": 8, "wall_construction": 3, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.9, "quantity": "square metres"}, "party_wall_length": {"value": 11.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 11.7, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.41, "quantity": "metres"}, "total_floor_area": {"value": 25.09, "quantity": "square metres"}, "party_wall_length": {"value": 10.24, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.24, "quantity": "metres"}}], "wall_insulation_type": 3, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 7, "wall_insulation_thickness": "100mm", "sloping_ceiling_insulation_thickness": "150mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 611, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Appliance thermostats", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 242, "currency": "GBP"}, "hot_water_cost_current": {"value": 181, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 70, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 60, "environmental_impact_rating": 64}, {"sequence": 2, "typical_saving": {"value": 393, "currency": "GBP"}, "indicative_cost": "\u00a33,000 - \u00a37,000", "improvement_type": "T", "improvement_details": {"improvement_number": 29}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 79}], "co2_emissions_potential": 1.4, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 403, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 96}, {"sequence": 2, "typical_saving": {"value": 353, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 79, "environmental_impact_rating": 81}, {"sequence": 3, "typical_saving": {"value": 338, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 73}], "hot_water_cost_potential": {"value": 87, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1125, "space_heating_existing_dwelling": 3787}, "energy_consumption_current": 274, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 140, "environmental_impact_current": 60, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "D", "environmental_impact_potential": 79, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 46, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 46059638, "roofs": [{"description": "Pitched, limited insulation (assumed)", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": "Cavity wall, as built, partial insulation (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "cavity_fill_recommended": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "E13 0PF", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-11-29 19:40:13.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2103, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17973}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Mid-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "72, Queens Road West", "assessment_type": "RdSAP", "completion_date": "2018-11-29", "inspection_date": "2018-11-29", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-11-29", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.26, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 15.58, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.3, "quantity": "metres"}, "total_floor_area": {"value": 37, "quantity": "square metres"}, "party_wall_length": {"value": 15.58, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 398, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.3, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Room thermostat only", "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 365, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 300, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2049, "impact_of_loft_insulation": -832, "impact_of_cavity_insulation": -782, "space_heating_existing_dwelling": 6522}, "energy_consumption_current": 179, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r07", "energy_consumption_potential": 76, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 31, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100100839018, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF64 2LD", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PENARTH", "built_form": 4, "created_at": "2018-10-12 14:15:38.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15700}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "8, Gainsborough Road", "assessment_type": "RdSAP", "completion_date": "2018-10-12", "inspection_date": "2018-10-12", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 73, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-12", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Portable electric heaters (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.28, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 37.49, "quantity": "square metres"}, "party_wall_length": {"value": 14.34, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 12.14, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.11, "quantity": "metres"}, "total_floor_area": {"value": 35.28, "quantity": "square metres"}, "party_wall_length": {"value": 14.34, "quantity": "metres"}, "heat_loss_perimeter": {"value": 9.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 455, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.4, "energy_rating_average": 60, "energy_rating_current": 70, "lighting_cost_current": {"value": 53, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 366, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 77}, {"sequence": 4, "typical_saving": {"value": 326, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.8, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 53, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 75}}], "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2035, "impact_of_cavity_insulation": -1142, "space_heating_existing_dwelling": 6072}, "energy_consumption_current": 189, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 57, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 766348341, "roofs": [{"description": "Pitched, 400+ mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "HP22 7AH", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "AYLESBURY", "built_form": 2, "created_at": "2018-07-28 18:47:45.000000", "door_count": 2, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2110, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17929}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "32, Pulver Road", "address_line_2": "Broughton", "assessment_type": "RdSAP", "completion_date": "2018-07-28", "inspection_date": "2018-07-24", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 68, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-07-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 330, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 34.06, "quantity": "square metres"}, "party_wall_length": {"value": 8.13, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.51, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.35, "quantity": "metres"}, "total_floor_area": {"value": 34.06, "quantity": "square metres"}, "party_wall_length": {"value": 8.13, "quantity": "metres"}, "heat_loss_perimeter": {"value": 16.51, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "400mm+", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 252, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.4, "energy_rating_average": 60, "energy_rating_current": 80, "lighting_cost_current": {"value": 54, "currency": "GBP"}, "main_heating_controls": [{"description": "Time and temperature zone control", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 252, "currency": "GBP"}, "hot_water_cost_current": {"value": 71, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 81, "environmental_impact_rating": 84}, {"sequence": 2, "typical_saving": {"value": 304, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 93, "environmental_impact_rating": 95}], "co2_emissions_potential": 0.3, "energy_rating_potential": 93, "lighting_cost_potential": {"value": 54, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 43, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1597, "space_heating_existing_dwelling": 3162}, "energy_consumption_current": 117, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r03", "energy_consumption_potential": 20, "environmental_impact_current": 82, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 95, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 21, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100090499851, "roofs": [{"description": {"value": "Pitched, 250 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": {"value": "Pitched, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, {"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "addendum": {"cavity_fill_recommended": "true"}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CM16 4JS", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "EPPING", "built_form": 2, "created_at": "2018-04-10 22:00:18.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16982}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "37, Western Avenue", "assessment_type": "RdSAP", "completion_date": "2018-04-10", "inspection_date": "2018-04-09", "extensions_count": 3, "measurement_type": 1, "total_floor_area": 111, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-04-10", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 35.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.43, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 35.08, "quantity": "square metres"}, "party_wall_length": {"value": 6.46, "quantity": "metres"}, "heat_loss_perimeter": {"value": 10.86, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.22, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 3.8, "quantity": "square metres"}, "party_wall_length": {"value": 0.82, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 5.46, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 2", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 3, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 5.17, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 8.06, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}, {"identifier": "Extension 3", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 4, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.46, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 16.41, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 5.08, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.36, "quantity": "metres"}, "total_floor_area": {"value": 15.04, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 11, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "L", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 562, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.2, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 71, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 498, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 64, "currency": "GBP"}, "indicative_cost": "\u00a3500 - \u00a31,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 74}, {"sequence": 2, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 76}, {"sequence": 3, "typical_saving": {"value": 293, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.8, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 71, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 33, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 77, "environmental_impact_rating": 76}}], "hot_water_cost_potential": {"value": 64, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2120, "impact_of_cavity_insulation": -1448, "space_heating_existing_dwelling": 10153}, "energy_consumption_current": 166, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 89, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 16, "windows_transmission_details": {"u_value": 2, "data_source": 2, "solar_transmittance": 0.72}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 16} +{"uprn": 100121115874, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, {"description": "Pitched, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": "Solid, insulated (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SN5 6BD", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SWINDON", "built_form": 2, "created_at": "2018-08-17 11:24:50.000000", "door_count": 2, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2104, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 9895}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 25}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Semi-detached house", "language_code": 1, "property_type": 0, "address_line_1": "2, Bainbridge Close", "address_line_2": "Grange Park", "assessment_type": "RdSAP", "completion_date": "2018-08-17", "inspection_date": "2018-08-16", "extensions_count": 1, "measurement_type": 2, "total_floor_area": 92, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-08-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": "NR", "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.3, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.28, "quantity": "square metres"}, "party_wall_length": {"value": 6.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 16.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.32, "quantity": "metres"}, "total_floor_area": {"value": 46.48, "quantity": "square metres"}, "party_wall_length": {"value": 5.7, "quantity": "metres"}, "heat_loss_perimeter": {"value": 22.1, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 5, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.31, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 14.56, "quantity": "square metres"}, "party_wall_length": {"value": 0, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 10.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "J", "party_wall_construction": "NI", "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 479, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.0, "energy_rating_average": 60, "energy_rating_current": 72, "lighting_cost_current": {"value": 64, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer and room thermostat", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 484, "currency": "GBP"}, "hot_water_cost_current": {"value": 133, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 309, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 64, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 79, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2882, "space_heating_existing_dwelling": 8397}, "energy_consumption_current": 185, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "sap_deselected_improvements": ["W2", "X"], "calculation_software_version": "3.06r03", "energy_consumption_potential": 106, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 11, "multiple_glazed_proportion_nr": "NR", "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 11} +{"uprn": 100090559537, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To unheated space, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in 40% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CM9 6JZ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "MALDON", "built_form": 4, "created_at": "2018-01-15 16:44:13.000000", "door_count": 1, "glazed_area": 1, "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10327}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "4, Gloucester Avenue", "assessment_type": "RdSAP", "completion_date": "2018-01-15", "inspection_date": "2018-01-15", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 74, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 4, "registration_date": "2018-01-15", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 12.12, "sheltered_wall": "N", "wall_dry_lined": "N", "wall_thickness": 280, "wall_construction": 4, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.36, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 32.29, "quantity": "square metres"}, "party_wall_length": {"value": 10.91, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.21, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.33, "quantity": "metres"}, "total_floor_area": {"value": 32.29, "quantity": "square metres"}, "party_wall_length": {"value": 10.91, "quantity": "metres"}, "heat_loss_perimeter": {"value": 8.84, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 2, "roof_construction": 4, "wall_construction": 3, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.33, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 9.53, "quantity": "square metres"}, "party_wall_length": 3.97, "floor_construction": 2, "heat_loss_perimeter": {"value": 2.4, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 40, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 472, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.8, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 84, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 356, "currency": "GBP"}, "hot_water_cost_current": {"value": 98, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "\u00a330", "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 75}, {"sequence": 4, "typical_saving": {"value": 33, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 77}, {"sequence": 5, "typical_saving": {"value": 305, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 88, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 88, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 66, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2087, "impact_of_loft_insulation": -417, "impact_of_cavity_insulation": -410, "impact_of_solid_wall_insulation": -2103, "space_heating_existing_dwelling": 8026}, "energy_consumption_current": 216, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 67, "environmental_impact_current": 66, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100068142, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Solid brick, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 75% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "RM9 5XR", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "DAGENHAM", "built_form": 3, "created_at": "2018-01-16 15:31:35.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 2, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10326}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Top-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "40, Haskard Road", "assessment_type": "RdSAP", "completion_date": "2018-01-16", "inspection_date": "2018-01-16", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": {"value": 4.8, "quantity": "metres"}}, "total_floor_area": 52, "transaction_type": 2, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-01-16", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 250, "floor_heat_loss": 6, "roof_construction": 4, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.76, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 150, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "total_floor_area": {"value": 51.5, "quantity": "square metres"}, "party_wall_length": {"value": 10.2, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.6, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 75, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 327, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.9, "energy_rating_average": 60, "energy_rating_current": 71, "lighting_cost_current": {"value": 48, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 212, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 90, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a314,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.2, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 48, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 89, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1849, "impact_of_loft_insulation": -545, "impact_of_solid_wall_insulation": -2034, "space_heating_existing_dwelling": 4772}, "energy_consumption_current": 205, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.1.0.0", "energy_consumption_potential": 138, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 8, "windows_transmission_details": {"u_value": 2.6, "data_source": 2, "solar_transmittance": 0.76}, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 36, "low_energy_fixed_lighting_outlets_count": 6} +{"uprn": 10002529641, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Suspended, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, {"description": {"value": "To external air, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in 30% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "CF5 4QW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "CARDIFF", "built_form": 1, "created_at": "2018-10-22 17:49:16.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": 12, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 26, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "N", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 101, "central_heating_pump_age": 0, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 609, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 50}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "77, Marguerites Way", "assessment_type": "RdSAP", "completion_date": "2018-10-22", "inspection_date": "2018-10-19", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 132, "transaction_type": 1, "conservatory_type": 3, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-10-22", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, mains gas", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 58.93, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 3, "heat_loss_perimeter": {"value": 36.37, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.4, "quantity": "metres"}, "total_floor_area": {"value": 56.97, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 26.97, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 1, "roof_construction": 4, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 15.7, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 2, "heat_loss_perimeter": {"value": 9.08, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "I", "party_wall_construction": "NA", "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 30, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 747, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.9, "energy_rating_average": 60, "energy_rating_current": 66, "lighting_cost_current": {"value": 139, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 595, "currency": "GBP"}, "hot_water_cost_current": {"value": 171, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 43, "currency": "GBP"}, "indicative_cost": 350, "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 67, "environmental_impact_rating": 61}, {"sequence": 2, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 68, "environmental_impact_rating": 63}, {"sequence": 3, "typical_saving": {"value": 48, "currency": "GBP"}, "indicative_cost": 35, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 64}, {"sequence": 4, "typical_saving": {"value": 116, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 69}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 71}, {"sequence": 6, "typical_saving": {"value": 316, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 82, "environmental_impact_rating": 78}], "co2_emissions_potential": 2.3, "energy_rating_potential": 82, "lighting_cost_potential": {"value": 82, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 178, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 75, "environmental_impact_rating": 69}}], "hot_water_cost_potential": {"value": 76, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2963, "impact_of_loft_insulation": -772, "space_heating_existing_dwelling": 11504}, "energy_consumption_current": 211, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 98, "environmental_impact_current": 59, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "D", "environmental_impact_potential": 78, "has_heated_separate_conservatory": "true", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 37, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 100070987630, "roofs": [{"description": "Pitched, 200 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "Cavity wall, filled cavity", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 90% of fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "B92 8EL", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOLIHULL", "built_form": 3, "created_at": "2018-12-13 10:15:52.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 17683}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace bungalow", "language_code": 1, "property_type": 1, "address_line_1": "8, Evenlode Close", "assessment_type": "RdSAP", "completion_date": "2018-12-13", "inspection_date": "2018-12-10", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 48, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-12-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 270, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.45, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 47.71, "quantity": "square metres"}, "party_wall_length": {"value": 6.2, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 23.6, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "200mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 90, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 393, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 350, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 42, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 25, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 289, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 87, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 50, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1684, "space_heating_existing_dwelling": 6355}, "energy_consumption_current": 255, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.08r08", "energy_consumption_potential": 97, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 10, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 45, "low_energy_fixed_lighting_outlets_count": 9} +{"uprn": 100023269151, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE3 8TT", "hot_water": {"description": "From main system", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 4, "created_at": "2018-05-13 15:24:18.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10243}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Ground Floor Flat", "address_line_2": "62 Charlton Road", "assessment_type": "RdSAP", "completion_date": "2018-05-13", "inspection_date": "2018-05-11", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 2, "unheated_corridor_length": 4.6}, "total_floor_area": 54, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-13", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 11.178, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "N", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.43, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 54.2, "quantity": "square metres"}, "party_wall_length": {"value": 16.07, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 21.73, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "C", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 376, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.1, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 228, "currency": "GBP"}, "hot_water_cost_current": {"value": 92, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 100, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 91, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2104, "impact_of_solid_wall_insulation": -2234, "space_heating_existing_dwelling": 5884}, "energy_consumption_current": 222, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": 139, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "C", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 39, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 100010595508, "roofs": [{"description": "Pitched, 250 mm loft insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "walls": [{"description": "System built, with external insulation", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": "Low energy lighting in 44% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "OL13 9LP", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BACUP", "built_form": 3, "created_at": "2018-03-21 14:46:29.000000", "door_count": 2, "glazed_area": 1, "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15271}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "21, Clough Road", "assessment_type": "RdSAP", "completion_date": "2018-03-21", "inspection_date": "2018-03-21", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 88, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-03-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 410, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.42, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.89, "quantity": "square metres"}, "party_wall_length": {"value": 6.64, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 20.54, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.46, "quantity": "metres"}, "total_floor_area": {"value": 43.89, "quantity": "square metres"}, "party_wall_length": {"value": 6.64, "quantity": "metres"}, "heat_loss_perimeter": {"value": 20.54, "quantity": "metres"}}], "wall_insulation_type": 1, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "250mm", "wall_insulation_thickness": "50mm", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 44, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 557, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 73, "lighting_cost_current": {"value": 94, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 521, "currency": "GBP"}, "hot_water_cost_current": {"value": 102, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 2, "typical_saving": {"value": 29, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 4, "typical_saving": {"value": 254, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 85}], "co2_emissions_potential": 2.0, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 71, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2171, "space_heating_existing_dwelling": 9905}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.04r01", "energy_consumption_potential": 129, "environmental_impact_current": 71, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "C", "environmental_impact_potential": 85, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 4} +{"uprn": 100100717030, "roofs": [{"description": {"value": "Pitched, 100 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Flat, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Granite or whinstone, as built, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": {"value": "Cavity wall, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"access_issues": "true", "high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 78% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CF37 3PE", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "PONTYPRIDD", "built_form": 2, "created_at": "2018-03-21 16:24:03.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16839}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "2, Heol-y-Mynach", "address_line_2": "Ynysybwl", "assessment_type": "RdSAP", "completion_date": "2018-03-21", "inspection_date": "2018-03-21", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 91, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 3, "pvc_window_frames": "true", "registration_date": "2018-03-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 1, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 25.84, "quantity": "square metres"}, "party_wall_length": {"value": 3.8, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 25.84, "quantity": "square metres"}, "party_wall_length": {"value": 3.8, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.2, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "100mm", "wall_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 24, "quantity": "square metres"}, "party_wall_length": 0, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 15.4, "quantity": "square metres"}, "party_wall_length": 0, "heat_loss_perimeter": {"value": 13.25, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "F", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 78, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 805, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 4.5, "energy_rating_average": 60, "energy_rating_current": 62, "lighting_cost_current": {"value": 75, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 512, "currency": "GBP"}, "hot_water_cost_current": {"value": 87, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 75, "currency": "GBP"}, "indicative_cost": "1,500", "improvement_type": "B", "improvement_details": {"improvement_number": 6}, "improvement_category": 5, "energy_performance_rating": 65, "environmental_impact_rating": 60}, {"sequence": 2, "typical_saving": {"value": 166, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 71}, {"sequence": 4, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 5, "typical_saving": {"value": 298, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 82}], "co2_emissions_potential": 1.8, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 75, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"improvement": {"sequence": 1, "typical_saving": {"value": 13, "currency": "GBP"}, "improvement_type": "Q2", "improvement_details": {"improvement_number": 55}, "improvement_category": 6, "energy_performance_rating": 66, "environmental_impact_rating": 60}}], "hot_water_cost_potential": {"value": 57, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1942, "impact_of_loft_insulation": -256, "impact_of_cavity_insulation": -1693, "impact_of_solid_wall_insulation": -3773, "space_heating_existing_dwelling": 15543}, "energy_consumption_current": 281, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 110, "environmental_impact_current": 56, "fixed_lighting_outlets_count": 9, "current_energy_efficiency_band": "D", "environmental_impact_potential": 82, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 50, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 202071217, "roofs": [{"description": {"value": "Pitched, 50 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Suspended, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NW9 8JJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 2, "created_at": "2018-02-07 14:45:39.000000", "door_count": 1, "glazed_area": 1, "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 4, "water_heating_code": 901, "water_heating_fuel": 26, "cylinder_thermostat": "Y", "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8557}], "immersion_heating_type": "NA", "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Semi-detached house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "51, Mallard Way", "assessment_type": "RdSAP", "completion_date": "2018-02-07", "inspection_date": "2017-09-14", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 87, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 5, "registration_date": "2018-02-07", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.5, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 43.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.5, "quantity": "metres"}, "total_floor_area": {"value": 43.25, "quantity": "square metres"}, "party_wall_length": {"value": 7.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 19.3, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "D", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "50mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 513, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.3, "energy_rating_average": 60, "energy_rating_current": 67, "lighting_cost_current": {"value": 60, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 390, "currency": "GBP"}, "hot_water_cost_current": {"value": 159, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a3100 - \u00a3350", "improvement_type": "A", "improvement_details": {"improvement_number": 5}, "improvement_category": 5, "energy_performance_rating": 69, "environmental_impact_rating": 66}, {"sequence": 2, "typical_saving": {"value": 49, "currency": "GBP"}, "indicative_cost": "\u00a3800 - \u00a31,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 69}, {"sequence": 3, "typical_saving": {"value": 65, "currency": "GBP"}, "indicative_cost": "\u00a32,200 - \u00a33,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 74, "environmental_impact_rating": 73}, {"sequence": 4, "typical_saving": {"value": 47, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 75}, {"sequence": 5, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 84}], "co2_emissions_potential": 1.2, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 60, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 40, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 73, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 63, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 70}], "hot_water_cost_potential": {"value": 74, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2946, "impact_of_loft_insulation": -923, "space_heating_existing_dwelling": 7893}, "energy_consumption_current": 215, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 77, "environmental_impact_current": 63, "fixed_lighting_outlets_count": 12, "current_energy_efficiency_band": "D", "environmental_impact_potential": 84, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 38, "low_energy_fixed_lighting_outlets_count": 12} +{"uprn": 10070389835, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "Cavity wall, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "(another dwelling below)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "LL11 5HJ", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WREXHAM", "built_form": 4, "created_at": "2018-10-05 19:43:54.000000", "door_count": 0, "glazed_area": 1, "glazing_gap": "16+", "region_code": 19, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 2, "rooms_with_mixer_shower_no_bath": 1, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 8875}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "28, John Wilkinson Court", "address_line_2": "Brymbo", "assessment_type": "RdSAP", "completion_date": "2018-10-05", "inspection_date": "2018-10-05", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 2, "top_storey": "N", "flat_location": 1, "heat_loss_corridor": 1}, "total_floor_area": 65, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 3, "registration_date": "2018-10-05", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 6, "roof_construction": 3, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.25, "quantity": "metres"}, "total_floor_area": {"value": 64.75, "quantity": "square metres"}, "party_wall_length": {"value": 17.5, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.8, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 155, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.0, "energy_rating_average": 60, "energy_rating_current": 84, "lighting_cost_current": {"value": 52, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 155, "currency": "GBP"}, "hot_water_cost_current": {"value": 95, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.0, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1930, "space_heating_existing_dwelling": 932}, "energy_consumption_current": 87, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 88, "fixed_lighting_outlets_count": 8, "current_energy_efficiency_band": "B", "environmental_impact_potential": 88, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 15, "low_energy_fixed_lighting_outlets_count": 8} +{"uprn": 10007559689, "roofs": [{"description": "Pitched, 300 mm loft insulation", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, {"description": "Flat, insulated (assumed)", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, {"description": "Cavity wall, as built, insulated (assumed)", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": "Solid, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Fully double glazed", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BD24 9NW", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SETTLE", "built_form": 3, "created_at": "2018-05-21 11:12:27.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 7, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "secondary_fuel_type": 9, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 15024}], "immersion_heating_type": "NA", "secondary_heating_type": 633, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "End-terrace house", "language_code": 1, "property_type": 0, "address_line_1": "9, Holme Head", "address_line_2": "Langcliffe", "assessment_type": "RdSAP", "completion_date": "2018-05-21", "inspection_date": "2018-05-16", "extensions_count": 1, "measurement_type": 1, "total_floor_area": 51, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-05-21", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 3}, "secondary_heating": {"description": "Room heaters, dual fuel (mineral and wood)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 600, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.37, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 22.3, "quantity": "square metres"}, "party_wall_length": {"value": 12.26, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.93, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.69, "quantity": "metres"}, "total_floor_area": {"value": 22.3, "quantity": "square metres"}, "party_wall_length": {"value": 12.36, "quantity": "metres"}, "heat_loss_perimeter": {"value": 7.22, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}, {"identifier": "Extension 1", "wall_dry_lined": "N", "wall_thickness": 325, "floor_heat_loss": 7, "roof_construction": 1, "wall_construction": 4, "building_part_number": 2, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.21, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 6.18, "quantity": "square metres"}, "party_wall_length": {"value": 2.7, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 4.5, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 6, "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI", "flat_roof_insulation_thickness": "AB"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 493, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 68, "lighting_cost_current": {"value": 38, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, room thermostat and TRVs", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 1, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 424, "currency": "GBP"}, "hot_water_cost_current": {"value": 81, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 68, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 28, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 74}, {"sequence": 3, "typical_saving": {"value": 267, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 87, "environmental_impact_rating": 87}, {"sequence": 4, "typical_saving": {"value": 576, "currency": "GBP"}, "indicative_cost": "25,000", "improvement_type": "V2", "improvement_details": {"improvement_number": 44}, "improvement_category": 5, "energy_performance_rating": 116, "environmental_impact_rating": 113}], "co2_emissions_potential": -0.6, "energy_rating_potential": 116, "lighting_cost_potential": {"value": 38, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 54, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1713, "impact_of_solid_wall_insulation": -1432, "space_heating_existing_dwelling": 7899}, "energy_consumption_current": 291, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "3.05r04", "energy_consumption_potential": -83, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 113, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "A", "co2_emissions_current_per_floor_area": 52, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 100062205320, "roofs": [{"description": "Pitched, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": "Solid brick, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "(another dwelling below)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": "Partial double glazing", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": "Low energy lighting in 29% of fixed outlets", "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "postcode": "BN11 3HN", "hot_water": {"description": "Electric immersion, standard tariff", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}, "post_town": "WORTHING", "built_form": 5, "created_at": "2018-03-21 17:06:57.000000", "door_count": 1, "glazed_area": 1, "region_code": 14, "report_type": 2, "sap_heating": {"cylinder_size": 2, "water_heating_code": 903, "water_heating_fuel": 29, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 0, "heat_emitter_type": 0, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2699, "main_heating_category": 1, "main_heating_fraction": 1, "sap_main_heating_code": 699, "main_heating_data_source": 2}], "immersion_heating_type": 2, "cylinder_insulation_type": 1, "has_fixed_air_conditioning": "false", "cylinder_insulation_thickness": 38}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "No system present: electric heaters assumed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 2}], "dwelling_type": "Top-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 4", "address_line_2": "7, Byron Road", "assessment_type": "RdSAP", "completion_date": "2018-03-21", "inspection_date": "2018-03-20", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 3, "top_storey": "Y", "flat_location": 1, "heat_loss_corridor": 2, "unheated_corridor_length": 4.6}, "total_floor_area": 53, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 0, "registration_date": "2018-03-21", "sap_energy_source": {"mains_gas": "N", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 320, "floor_heat_loss": 6, "roof_construction": 5, "wall_construction": 3, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 13.57, "sheltered_wall": "Y", "wall_dry_lined": "N", "wall_thickness": 320, "wall_construction": 3, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.95, "quantity": "metres"}, "total_floor_area": {"value": 52.95, "quantity": "square metres"}, "party_wall_length": {"value": 1.85, "quantity": "metres"}, "heat_loss_perimeter": {"value": 33.39, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "A", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 29, "solar_water_heating": "N", "habitable_room_count": 3, "heating_cost_current": {"value": 1989, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 7.5, "energy_rating_average": 60, "energy_rating_current": 1, "lighting_cost_current": {"value": 68, "currency": "GBP"}, "main_heating_controls": [{"description": "None", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "true", "heating_cost_potential": {"value": 624, "currency": "GBP"}, "hot_water_cost_current": {"value": 276, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 70, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 690, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 18, "environmental_impact_rating": 30}, {"sequence": 2, "typical_saving": {"value": 17, "currency": "GBP"}, "indicative_cost": 25, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 19, "environmental_impact_rating": 30}, {"sequence": 3, "typical_saving": {"value": 822, "currency": "GBP"}, "indicative_cost": "1,800", "improvement_type": "L2", "improvement_details": {"improvement_number": 61}, "improvement_category": 5, "energy_performance_rating": 56, "environmental_impact_rating": 33}], "co2_emissions_potential": 5.0, "energy_rating_potential": 56, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 993, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 61, "environmental_impact_rating": 94}, {"sequence": 2, "typical_saving": {"value": 864, "currency": "GBP"}, "improvement_type": "Z1", "improvement_details": {"improvement_number": 51}, "improvement_category": 6, "energy_performance_rating": 58, "environmental_impact_rating": 62}], "hot_water_cost_potential": {"value": 136, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1714, "impact_of_loft_insulation": -4261, "impact_of_solid_wall_insulation": -4586, "space_heating_existing_dwelling": 12336}, "energy_consumption_current": 839, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 70, "calculation_software_version": "3.04r01", "energy_consumption_potential": 554, "environmental_impact_current": 16, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "G", "environmental_impact_potential": 33, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "D", "co2_emissions_current_per_floor_area": 142, "low_energy_fixed_lighting_outlets_count": 2} +{"uprn": 100071249718, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 2, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "CV35 9TF", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "WARWICK", "built_form": 4, "created_at": "2018-09-28 12:57:29.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 6, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "secondary_fuel_type": 29, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "sap_main_heating_code": 104, "central_heating_pump_age": 1, "main_heating_data_source": 2}], "immersion_heating_type": "NA", "secondary_heating_type": 691, "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace bungalow", "language": "1"}, "language_code": 1, "property_type": 1, "address_line_1": "Flat 8 Farrington Court", "address_line_2": "Farrington Close", "address_line_3": "Wellesbourne", "assessment_type": "RdSAP", "completion_date": "2018-09-28", "inspection_date": "2018-07-06", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 55, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-09-28", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "Room heaters, electric", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 300, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.4, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 55, "quantity": "square metres"}, "party_wall_length": {"value": 15, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 18, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "50mm"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 435, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.2, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 41, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 389, "currency": "GBP"}, "hot_water_cost_current": {"value": 90, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 46, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 71, "environmental_impact_rating": 72}, {"sequence": 2, "typical_saving": {"value": 32, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 75}, {"sequence": 3, "typical_saving": {"value": 290, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 86, "environmental_impact_rating": 87}], "co2_emissions_potential": 0.9, "energy_rating_potential": 86, "lighting_cost_potential": {"value": 41, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 58, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1781, "space_heating_existing_dwelling": 5445}, "energy_consumption_current": 233, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 90, "environmental_impact_current": 69, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 87, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 41, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 200003414341, "roofs": [{"description": {"value": "Pitched, 300 mm loft insulation", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "walls": [{"description": {"value": "Timber frame, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "SE16 6DW", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "LONDON", "built_form": 3, "created_at": "2018-08-20 11:14:03.000000", "door_count": 1, "glazed_area": 1, "glazing_gap": "16+", "region_code": 17, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16842}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "End-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "53, Kinburn Street", "assessment_type": "RdSAP", "completion_date": "2018-08-20", "inspection_date": "2018-08-20", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 58, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 4, "pvc_window_frames": "true", "registration_date": "2018-08-20", "sap_energy_source": {"mains_gas": "Y", "meter_type": 3, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 5, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.339, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 28.18, "quantity": "square metres"}, "party_wall_length": {"value": 6.253, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 15.26, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.367, "quantity": "metres"}, "total_floor_area": {"value": 30.03, "quantity": "square metres"}, "party_wall_length": {"value": 6.644, "quantity": "metres"}, "heat_loss_perimeter": {"value": 15.68, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "G", "party_wall_construction": 0, "wall_thickness_measured": "N", "roof_insulation_location": 2, "roof_insulation_thickness": "300mm", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 4, "heating_cost_current": {"value": 305, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.7, "energy_rating_average": 60, "energy_rating_current": 74, "lighting_cost_current": {"value": 44, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 281, "currency": "GBP"}, "hot_water_cost_current": {"value": 75, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 24, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 75, "environmental_impact_rating": 76}, {"sequence": 2, "typical_saving": {"value": 27, "currency": "GBP"}, "indicative_cost": "\u00a34,000 - \u00a36,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 77, "environmental_impact_rating": 79}, {"sequence": 3, "typical_saving": {"value": 297, "currency": "GBP"}, "indicative_cost": "\u00a35,000 - \u00a38,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 90, "environmental_impact_rating": 90}], "co2_emissions_potential": 0.4, "energy_rating_potential": 90, "lighting_cost_potential": {"value": 44, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 48, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1683, "space_heating_existing_dwelling": 4374}, "energy_consumption_current": 164, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 40, "environmental_impact_current": 74, "fixed_lighting_outlets_count": 7, "current_energy_efficiency_band": "C", "environmental_impact_potential": 90, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 29, "low_energy_fixed_lighting_outlets_count": 7} +{"uprn": 100060363243, "roofs": [{"description": {"value": "Pitched, limited insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "walls": [{"description": {"value": "Cavity wall, filled cavity", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, {"description": {"value": "Timber frame, as built, partial insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}], "floors": [{"description": {"value": "Solid, no insulation (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 3, "environmental_efficiency_rating": 3}, "addendum": {"high_exposure": "true"}, "lighting": {"description": {"value": "Low energy lighting in 19% of fixed outlets", "language": "1"}, "energy_efficiency_rating": 2, "environmental_efficiency_rating": 2}, "postcode": "SO31 7BU", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "SOUTHAMPTON", "built_form": 4, "created_at": "2018-01-17 21:53:19.000000", "door_count": 2, "glazed_area": 1, "glazing_gap": "16+", "region_code": 16, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 16375}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Mid-terrace house", "language": "1"}, "language_code": 1, "property_type": 0, "address_line_1": "40, Barnes Close", "address_line_2": "Sarisbury Green", "assessment_type": "RdSAP", "completion_date": "2018-01-17", "inspection_date": "2018-01-17", "extensions_count": 0, "measurement_type": 1, "total_floor_area": 81, "transaction_type": 1, "conservatory_type": 1, "heated_room_count": 5, "pvc_window_frames": "true", "registration_date": "2018-01-17", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 280, "floor_heat_loss": 7, "roof_construction": 4, "wall_construction": 4, "building_part_number": 1, "sap_alternative_wall": {"wall_area": 15.8, "wall_dry_lined": "N", "wall_thickness": 220, "wall_construction": 5, "wall_insulation_type": 4, "wall_thickness_measured": "Y", "wall_insulation_thickness": "NI"}, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.24, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 40.68, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "floor_construction": 1, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}, {"floor": 1, "room_height": {"value": 2.24, "quantity": "metres"}, "total_floor_area": {"value": 40.68, "quantity": "square metres"}, "party_wall_length": {"value": 11.3, "quantity": "metres"}, "heat_loss_perimeter": {"value": 14.4, "quantity": "metres"}}], "wall_insulation_type": 2, "construction_age_band": "E", "party_wall_construction": 1, "wall_thickness_measured": "Y", "roof_insulation_location": 4, "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 19, "solar_water_heating": "N", "habitable_room_count": 5, "heating_cost_current": {"value": 448, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 2.7, "energy_rating_average": 60, "energy_rating_current": 69, "lighting_cost_current": {"value": 102, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 3, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 432, "currency": "GBP"}, "hot_water_cost_current": {"value": 94, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 22, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "W2", "improvement_details": {"improvement_number": 58}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 2, "typical_saving": {"value": 41, "currency": "GBP"}, "indicative_cost": 65, "improvement_type": "E", "improvement_details": {"improvement_number": 35}, "improvement_category": 5, "energy_performance_rating": 72, "environmental_impact_rating": 70}, {"sequence": 3, "typical_saving": {"value": 31, "currency": "GBP"}, "indicative_cost": "6,000", "improvement_type": "N", "improvement_details": {"improvement_number": 19}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 4, "typical_saving": {"value": 314, "currency": "GBP"}, "indicative_cost": "8,000", "improvement_type": "U", "improvement_details": {"improvement_number": 34}, "improvement_category": 5, "energy_performance_rating": 84, "environmental_impact_rating": 81}], "co2_emissions_potential": 1.3, "energy_rating_potential": 84, "lighting_cost_potential": {"value": 56, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 63, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 2076, "impact_of_loft_insulation": -2168, "space_heating_existing_dwelling": 7503}, "energy_consumption_current": 190, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "2.0.x", "energy_consumption_potential": 87, "environmental_impact_current": 67, "fixed_lighting_outlets_count": 16, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "B", "co2_emissions_current_per_floor_area": 33, "low_energy_fixed_lighting_outlets_count": 3} +{"uprn": 10070838229, "roofs": [{"description": {"value": "(another dwelling above)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": {"value": "System built, as built, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}], "floors": [{"description": {"value": "Suspended, insulated (assumed)", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 1, "window": {"description": {"value": "Fully double glazed", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "lighting": {"description": {"value": "Low energy lighting in all fixed outlets", "language": "1"}, "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "NE10 0DP", "hot_water": {"description": {"value": "From main system", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "GATESHEAD", "built_form": 2, "created_at": "2018-09-19 17:42:47.000000", "door_count": 2, "glazed_area": 1, "region_code": 1, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 1}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": 0, "main_heating_number": 1, "main_heating_control": 2106, "main_heating_category": 2, "main_heating_fraction": 1, "mcs_installed_heat_pump": "false", "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 10265}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Address Matched", "country_code": "EAW", "main_heating": [{"description": {"value": "Boiler and radiators, mains gas", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": {"value": "Ground-floor flat", "language": "1"}, "language_code": 1, "property_type": 2, "address_line_1": "Flat 17 Block F", "address_line_2": "Marigold Avenue", "address_line_3": "St James Village", "assessment_type": "RdSAP", "completion_date": "2018-09-19", "inspection_date": "2018-09-06", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 47, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "pvc_window_frames": "true", "registration_date": "2018-09-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": {"value": "None", "language": "1"}, "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "Y", "wall_thickness": 290, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 8, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.63, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 46.64, "quantity": "square metres"}, "party_wall_length": {"value": 5.3, "quantity": "metres"}, "floor_construction": 3, "heat_loss_perimeter": {"value": 22.9, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "K", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 231, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 1.3, "energy_rating_average": 60, "energy_rating_current": 78, "lighting_cost_current": {"value": 40, "currency": "GBP"}, "main_heating_controls": [{"description": {"value": "Programmer, room thermostat and TRVs", "language": "1"}, "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "multiple_glazing_type": 2, "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 231, "currency": "GBP"}, "hot_water_cost_current": {"value": 77, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 100, "co2_emissions_potential": 1.3, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 40, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "hot_water_cost_potential": {"value": 77, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1647, "space_heating_existing_dwelling": 2674}, "energy_consumption_current": 155, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 100, "calculation_software_version": "v93.0.1.1", "energy_consumption_potential": 155, "environmental_impact_current": 81, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "C", "environmental_impact_potential": 81, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 27, "low_energy_fixed_lighting_outlets_count": 5} +{"uprn": 266316, "roofs": [{"description": "(another dwelling above)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "walls": [{"description": "Sandstone or limestone, as built, no insulation (assumed)", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "floors": [{"description": "Suspended, no insulation (assumed)", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}], "status": "entered", "tenure": 3, "window": {"description": "Single glazed", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}, "addendum": {"stone_walls": "true"}, "lighting": {"description": "Low energy lighting in all fixed outlets", "energy_efficiency_rating": 5, "environmental_efficiency_rating": 5}, "postcode": "BS8 2TU", "hot_water": {"description": "From main system", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}, "post_town": "BRISTOL", "built_form": 3, "created_at": "2018-02-19 16:20:14.000000", "door_count": 1, "glazed_area": 1, "region_code": 12, "report_type": 2, "sap_heating": {"cylinder_size": 1, "water_heating_code": 901, "water_heating_fuel": 26, "instantaneous_wwhrs": {"rooms_with_bath_and_or_shower": 1, "rooms_with_mixer_shower_no_bath": 0, "rooms_with_bath_and_mixer_shower": 0}, "main_heating_details": [{"has_fghrs": "N", "main_fuel_type": 26, "boiler_flue_type": 2, "fan_flue_present": "Y", "heat_emitter_type": 1, "emitter_temperature": "NA", "main_heating_number": 1, "main_heating_control": 2102, "main_heating_category": 2, "main_heating_fraction": 1, "central_heating_pump_age": 0, "main_heating_data_source": 1, "main_heating_index_number": 1730}], "immersion_heating_type": "NA", "has_fixed_air_conditioning": "false"}, "sap_version": 9.93, "schema_type": "RdSAP-Schema-18.0", "uprn_source": "Energy Assessor", "country_code": "EAW", "main_heating": [{"description": "Boiler and radiators, mains gas", "energy_efficiency_rating": 4, "environmental_efficiency_rating": 4}], "dwelling_type": "Ground-floor flat", "language_code": 1, "property_type": 2, "address_line_1": "Flat 1", "address_line_2": "86 Worrall Road", "assessment_type": "RdSAP", "completion_date": "2018-02-19", "inspection_date": "2018-02-19", "extensions_count": 0, "measurement_type": 1, "sap_flat_details": {"level": 1, "top_storey": "N", "flat_location": 0, "heat_loss_corridor": 0}, "total_floor_area": 69, "transaction_type": 8, "conservatory_type": 1, "heated_room_count": 2, "registration_date": "2018-02-19", "sap_energy_source": {"mains_gas": "Y", "meter_type": 2, "photovoltaic_supply": {"none_or_no_details": {"pv_connection": 0, "percent_roof_area": 0}}, "wind_turbines_count": 0, "wind_turbines_terrain_type": 2}, "secondary_heating": {"description": "None", "energy_efficiency_rating": 0, "environmental_efficiency_rating": 0}, "sap_building_parts": [{"identifier": "Main Dwelling", "wall_dry_lined": "N", "wall_thickness": 580, "floor_heat_loss": 7, "roof_construction": 3, "wall_construction": 2, "building_part_number": 1, "sap_floor_dimensions": [{"floor": 0, "room_height": {"value": 2.61, "quantity": "metres"}, "floor_insulation": 1, "total_floor_area": {"value": 69.07, "quantity": "square metres"}, "party_wall_length": {"value": 11.42, "quantity": "metres"}, "floor_construction": 2, "heat_loss_perimeter": {"value": 24.24, "quantity": "metres"}}], "wall_insulation_type": 4, "construction_age_band": "B", "party_wall_construction": 0, "wall_thickness_measured": "Y", "roof_insulation_location": "ND", "roof_insulation_thickness": "ND", "wall_insulation_thickness": "NI", "floor_insulation_thickness": "NI"}], "low_energy_lighting": 100, "solar_water_heating": "N", "habitable_room_count": 2, "heating_cost_current": {"value": 693, "currency": "GBP"}, "insulated_door_count": 0, "co2_emissions_current": 3.9, "energy_rating_average": 60, "energy_rating_current": 56, "lighting_cost_current": {"value": 51, "currency": "GBP"}, "main_heating_controls": [{"description": "Programmer, no room thermostat", "energy_efficiency_rating": 1, "environmental_efficiency_rating": 1}], "multiple_glazing_type": "ND", "open_fireplaces_count": 0, "has_hot_water_cylinder": "false", "heating_cost_potential": {"value": 261, "currency": "GBP"}, "hot_water_cost_current": {"value": 109, "currency": "GBP"}, "mechanical_ventilation": 0, "percent_draughtproofed": 20, "suggested_improvements": [{"sequence": 1, "typical_saving": {"value": 209, "currency": "GBP"}, "indicative_cost": "14,000", "improvement_type": "Q", "improvement_details": {"improvement_number": 7}, "improvement_category": 5, "energy_performance_rating": 66, "environmental_impact_rating": 62}, {"sequence": 2, "typical_saving": {"value": 72, "currency": "GBP"}, "indicative_cost": "1,200", "improvement_type": "W1", "improvement_details": {"improvement_number": 57}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 68}, {"sequence": 3, "typical_saving": {"value": 8, "currency": "GBP"}, "indicative_cost": 120, "improvement_type": "D", "improvement_details": {"improvement_number": 10}, "improvement_category": 5, "energy_performance_rating": 70, "environmental_impact_rating": 69}, {"sequence": 4, "typical_saving": {"value": 57, "currency": "GBP"}, "indicative_cost": 450, "improvement_type": "G", "improvement_details": {"improvement_number": 12}, "improvement_category": 5, "energy_performance_rating": 73, "environmental_impact_rating": 72}, {"sequence": 5, "typical_saving": {"value": 50, "currency": "GBP"}, "indicative_cost": "3,000", "improvement_type": "I", "improvement_details": {"improvement_number": 20}, "improvement_category": 5, "energy_performance_rating": 76, "environmental_impact_rating": 76}, {"sequence": 6, "typical_saving": {"value": 51, "currency": "GBP"}, "indicative_cost": "6,500", "improvement_type": "O", "improvement_details": {"improvement_number": 8}, "improvement_category": 5, "energy_performance_rating": 78, "environmental_impact_rating": 80}], "co2_emissions_potential": 1.6, "energy_rating_potential": 78, "lighting_cost_potential": {"value": 52, "currency": "GBP"}, "schema_version_original": "LIG-18.0", "alternative_improvements": [{"sequence": 1, "typical_saving": {"value": 52, "currency": "GBP"}, "improvement_type": "J2", "improvement_details": {"improvement_number": 54}, "improvement_category": 6, "energy_performance_rating": 76, "environmental_impact_rating": 95}, {"sequence": 2, "typical_saving": {"value": 21, "currency": "GBP"}, "improvement_type": "Z3", "improvement_details": {"improvement_number": 53}, "improvement_category": 6, "energy_performance_rating": 74, "environmental_impact_rating": 71}], "hot_water_cost_potential": {"value": 95, "currency": "GBP"}, "renewable_heat_incentive": {"water_heating": 1990, "impact_of_solid_wall_insulation": -3757, "space_heating_existing_dwelling": 10300}, "energy_consumption_current": 324, "has_fixed_air_conditioning": "false", "multiple_glazed_proportion": 0, "calculation_software_version": "3.04r01", "energy_consumption_potential": 128, "environmental_impact_current": 49, "fixed_lighting_outlets_count": 5, "current_energy_efficiency_band": "D", "environmental_impact_potential": 80, "has_heated_separate_conservatory": "false", "potential_energy_efficiency_band": "C", "co2_emissions_current_per_floor_area": 57, "low_energy_fixed_lighting_outlets_count": 5} diff --git a/datatypes/epc/domain/tests/test_from_rdsap_schema.py b/datatypes/epc/domain/tests/test_from_rdsap_schema.py index 924fdc30..dd40a3ab 100644 --- a/datatypes/epc/domain/tests/test_from_rdsap_schema.py +++ b/datatypes/epc/domain/tests/test_from_rdsap_schema.py @@ -1424,3 +1424,45 @@ class TestRdSap20_0_0ReducedFieldSynthesis: assert len(result.sap_windows) == len(lodged) total_area = sum(w.window_width * w.window_height for w in result.sap_windows) assert total_area == pytest.approx(expected_total) + + +# --------------------------------------------------------------------------- +# RdSAP 18.0 Reduced-Field Synthesis (ADR-0028 — inherit-and-validate). 18.0 is +# the same pre-SAP10 reduced family as 20.0.0: glazed_area *band* not window m², +# bath/shower *room counts* not bath counts, lighting OUTLET counts not bulbs. +# The mapper synthesises the measured form from the cert alone (no neighbour +# data), reusing 20.0.0's coefficients (validated against 18.0's own band-4 rich +# certs: observed 0.223 ≈ 0.148 × 1.51). Each test name pins one assumption, +# because a pre-SAP10 cert has no same-spec lodged figure (Validation-Cohort). +# --------------------------------------------------------------------------- + +_CORPUS_18_0 = os.path.join( + os.path.dirname(__file__), + "../../../../backend/epc_api/json_samples/RdSAP-Schema-18.0/corpus.jsonl", +) + + +def _load_18_0_corpus() -> list[Dict[str, Any]]: + if not os.path.exists(_CORPUS_18_0): + return [] + with open(_CORPUS_18_0) as f: + return [json.loads(line) for line in f if line.strip()] + + +class TestRdSap18_0ReducedFieldSynthesis: + + def test_cert_dispatches_and_maps_without_missing_required_field(self) -> None: + # Arrange — the placeholder 18.0 schema was generated from one example, so + # 986/1000 corpus certs fail to parse (over-constrained required fields), + # and `from_api_response` never dispatched RdSAP-Schema-18.0 at all. + # Dispatch + required→optional must let a real cert through end-to-end. + corpus = _load_18_0_corpus() + if not corpus: + pytest.skip("no RdSAP-Schema-18.0 corpus harvested") + cert = corpus[0] + + # Act + result = EpcPropertyDataMapper.from_api_response(cert) + + # Assert + assert isinstance(result, EpcPropertyData) diff --git a/scripts/eon/find_epc_data.py b/scripts/eon/find_epc_data.py new file mode 100644 index 00000000..fc900ba9 --- /dev/null +++ b/scripts/eon/find_epc_data.py @@ -0,0 +1,114 @@ +from __future__ import annotations + +import os +from pathlib import Path +from typing import Any, Optional + +import pandas as pd +from dotenv import load_dotenv + +from datatypes.epc.domain.epc import Epc +from datatypes.epc.domain.mapper import EpcPropertyDataMapper +from domain.sap10_calculator.calculator import calculate_sap_from_inputs +from domain.sap10_calculator.rdsap.cert_to_inputs import cert_to_inputs +from infrastructure.epc_client.epc_client_service import EpcClientService + +# UPRNs to compare. Most are RdSAP 20.0.0 (pre-SAP10) certs — the ones the +# Reduced-Field Synthesis mapper (ADR-0027) re-maps so the SAP10 calculator can +# re-score them. The commented rows are non-20.0.0 neighbours kept for context. +UPRNS: list[int] = [ + 10003318624, # 20.0.0 Flat 1, 6 Alexandra Gardens, PO38 1EE + 10003318625, # 20.0.0 Flat 2, 6 Alexandra Gardens, PO38 1EE + 10003318626, # 20.0.0 Flat 3, 6 Alexandra Gardens, PO38 1EE + # 10003318698, # 17.1 Flat 4, 6 Alexandra Gardens, PO38 1EE + 100062430247, # 20.0.0 Flat 5, Adelaide Court, Adelaide Place, PO33 3DG + 100062430248, # 20.0.0 Flat 6, Adelaide Court, Adelaide Place, PO33 3DG + 100062430250, # 20.0.0 Flat 8, Adelaide Court, Adelaide Place, PO33 3DG + 100062429797, # 20.0.0 Flat 1, 10-11 Cross Street, PO33 2AD + 10003320577, # 20.0.0 Flat 3, 10-11 Cross Street, PO33 2AD + # 10003320573, # 18.0 Flat 7, 10-11 Cross Street, PO33 2AD + 10024248769, # 20.0.0 Flat 8, 10-11 Cross Street, PO33 2AD + # 10024248772, # 18.0 Flat 9, 10-11 Cross Street, PO33 2AD +] + + +def fetch_raw_cert(service: EpcClientService, uprn: int) -> Optional[dict[str, Any]]: + """Pull the latest raw certificate dict for a UPRN straight off the EPC + client. We want the RAW cert (not the mapped EpcPropertyData) because the + lodged SAP score lives there as `energy_rating_current` — the mapper does + not carry it onto the domain object. + """ + results = service._search(uprn=uprn) # pyright: ignore[reportPrivateUsage] + if not results: + return None + latest = max(results, key=lambda r: r.registration_date) + return service._fetch_certificate( # pyright: ignore[reportPrivateUsage] + latest.certificate_number + ) + + +def compare_sap(raw: dict[str, Any]) -> dict[str, object]: + """Re-score a raw cert through our SAP10 calculator and line it up against + the figure the surveyor lodged. For a 20.0.0 cert the calculated value is + the counterfactual "what EPC would this get under today's spec" (ADR-0027). + """ + epc = EpcPropertyDataMapper.from_api_response(raw) + result = calculate_sap_from_inputs(cert_to_inputs(epc)) + + # Lodged Performance: the surveyor's original SAP score, read directly from + # the raw cert. Bands are derived from the score the same way for both sides. + lodged_score = raw.get("energy_rating_current") + lodged_band = ( + Epc.from_sap_score(lodged_score).value if lodged_score is not None else "?" + ) + our_band = Epc.from_sap_score(result.sap_score).value + + return { + "address": epc.address_line_1, + "postcode": epc.postcode, + # The SAP methodology version (RdSAP 2012 lodges 9.9x); the *schema* + # version (20.0.0) is annotated in the UPRNS list above. + "sap_ver": raw.get("sap_version"), + "lodged_sap": lodged_score, + "lodged_band": lodged_band, + "our_sap": result.sap_score, + "our_band": our_band, + "delta": ( + result.sap_score - lodged_score if lodged_score is not None else None + ), + } + + +def main() -> None: + # Mirror conftest.py: pull OPEN_EPC_API_TOKEN out of backend/.env so the + # script runs standalone (`python scripts/eon/find_epc_data.py`). + repo_root = Path(__file__).resolve().parents[2] + load_dotenv(repo_root / "backend" / ".env") + + token = os.getenv("OPEN_EPC_API_TOKEN") + if token is None: + raise RuntimeError("OPEN_EPC_API_TOKEN not defined in env") + service = EpcClientService(auth_token=token) + + rows: list[dict[str, object]] = [] + for uprn in UPRNS: + raw = fetch_raw_cert(service, uprn) + if raw is None: + print(f"UPRN {uprn}: no EPC found") + continue + try: + rows.append({"uprn": uprn, **compare_sap(raw)}) + except Exception as exc: # surface, don't abort the whole sweep + print(f"UPRN {uprn}: failed to score — {type(exc).__name__}: {exc}") + + if not rows: + print("No certs scored.") + return + + table = pd.DataFrame(rows) + with pd.option_context("display.max_columns", None, "display.width", None): + print(table.to_string(index=False)) + + +if __name__ == "__main__": + main() diff --git a/scripts/eon/harvest_certs.py b/scripts/eon/harvest_certs.py new file mode 100644 index 00000000..6ced576d --- /dev/null +++ b/scripts/eon/harvest_certs.py @@ -0,0 +1,96 @@ +"""Harvest raw EPC certificates into a JSONL corpus for mapper tests. + +Source: the bulk EPC dumps in downloads/certificates-YYYY.json. Each line is + + {"certificate_number": "...", "document": "", ...} + +where ``document`` is the cert in the exact shape +``EpcClientService._fetch_certificate`` returns and +``EpcPropertyDataMapper.from_api_response`` consumes (it has ``schema_type``, +``roofs``, ``walls`` ... and matches the committed json_samples). + +We want a balanced sample per schema so we can build out and regression-test +the mappers (notably the incomplete ``RdSapSchema20.0.0``). Schema version +tracks the dump year, so we read each target schema from a year that's rich in +it and stop once its cap is full — no need to stream whole multi-GB files. + +Year -> dominant schema (see downloads/README.txt): + 2026 -> RdSAP-Schema-21.0.1 + 2021-2024 -> RdSAP-Schema-20.0.0 + +SAP-Schema-18.0.0 is a minority schema (~12% of the 2021 dump) but each year +holds ~1.6M lines, so 2021 still yields well over 1000 — it just scans deeper +before the cap fills. SAP-Schema-17.1 is richest in the 2019 dump (~20%). + +21.0.0 is skipped — it's effectively absent from these dumps. + +Run cell by cell. No API token needed — this is pure local streaming. +""" + +from __future__ import annotations + +import json +from pathlib import Path + +import pandas as pd + +DOWNLOADS = Path("downloads") +SAMPLES = Path("backend/epc_api/json_samples") + +# One corpus per schema, written into that schema's own json_samples folder +# (alongside its epc.json) as corpus.jsonl. Each schema is read from a year +# where it dominates, so we hit the cap within the first few-thousand lines. +SOURCES: list[tuple[str, str, int]] = [ + # ("certificates-2026.json", "RdSAP-Schema-21.0.1", 1000), + # ("certificates-2022.json", "RdSAP-Schema-20.0.0", 1000), + # pre-SAP10 RdSAP family — NOT the SAP-Schema-* full/design-SAP family. + # schema_type scan: RdSAP-Schema-18.0 is ~82% of certificates-2018.json, + # 17.1 dominant in 2017, 17.0 dominant in 2015. + ("certificates-2018.json", "RdSAP-Schema-18.0", 1000), + ("certificates-2017.json", "RdSAP-Schema-17.1", 1000), + # ("certificates-2015.json", "RdSAP-Schema-17.0", 1000), +] + + +def corpus_path(schema: str) -> Path: + return SAMPLES / schema / "corpus.jsonl" + + +# %% +def harvest_one(filename: str, schema: str, cap: int) -> list[dict[str, object]]: + """Stream `filename`, returning up to `cap` cert docs of `schema`.""" + path = DOWNLOADS / filename + docs: list[dict[str, object]] = [] + scanned = 0 + with path.open() as fh: + for line in fh: + if len(docs) >= cap: + break + scanned += 1 + try: + doc = json.loads(json.loads(line)["document"]) + except (json.JSONDecodeError, KeyError): + continue + if doc.get("schema_type") == schema: + docs.append(doc) + print(f"{schema}: {len(docs)}/{cap} from {filename} (scanned {scanned} lines)") + return docs + + +# %% +# Build one corpus per schema, into that schema's json_samples folder. +# Overwrites each run — deterministic and cheap. +for filename, schema, cap in SOURCES: + out_path = corpus_path(schema) + out_path.parent.mkdir(parents=True, exist_ok=True) + with out_path.open("w") as out: + for doc in harvest_one(filename, schema, cap): + out.write(json.dumps(doc) + "\n") + print(f"wrote {out_path}") + +# %% +# Sanity-check each corpus: line count per schema. +for _, schema, _ in SOURCES: + path = corpus_path(schema) + n = sum(1 for line in path.read_text().splitlines() if line.strip()) + print(f"{schema}: {n} ({path})")